Fact-checked by Grok 2 weeks ago

Physical layer

The Physical layer, designated as Layer 1 in the Open Systems Interconnection (OSI) reference model, is the foundational layer responsible for the transmission and reception of unstructured raw bit streams—sequences of 1s and 0s—over a physical medium between networked devices. Defined in the ISO/IEC 7498-1 standard, it establishes the electrical, mechanical, procedural, and functional specifications necessary for activating, maintaining, and deactivating physical links, without regard to the logical meaning or structure of the data being transmitted. This layer handles the conversion of digital data into analog signals suitable for physical media such as twisted-pair copper cables, coaxial cables, fiber optic lines, or wireless radio frequencies. Key functions of the Physical layer include bit-level synchronization to ensure accurate timing of data transmission, signal modulation and encoding to adapt bits to the medium's characteristics, and management of physical topology such as point-to-point, multipoint, or broadcast configurations. It also encompasses error detection at the signal level, such as through techniques like Manchester encoding or non-return-to-zero (NRZ), and defines parameters like voltage levels, data rates, and maximum transmission distances to prevent signal degradation. Unlike higher layers, the Physical layer operates independently of protocols or applications, focusing solely on the hardware-level mechanics of data flow, which makes it essential for interoperability across diverse network environments. Devices and components at the Physical layer include network interface cards (NICs), which implement signal conversion in endpoints like computers; repeaters and hubs, which amplify or regenerate signals to extend network reach; and modems, which modulate digital signals for transmission over analog media. Prominent standards governing this layer include IEEE 802.3 for Ethernet, specifying physical layer signaling for wired local area networks up to 800 Gb/s speeds (as of 2024); IEEE 802.11 for Wi-Fi, defining radio frequency physical layers for wireless connectivity; and older protocols like RS-232 for serial communications. These standards ensure compatibility and performance, with ongoing updates addressing emerging needs like higher bandwidths and energy efficiency in modern infrastructures such as 5G and data centers.

Overview and Role

Definition and Purpose

The physical layer, designated as Layer 1 in the Open Systems Interconnection (OSI) reference model, is responsible for the transmission and reception of unstructured bit streams over a physical medium connecting adjacent nodes in a network. This layer operates without performing error correction, flow control, or addressing functions, focusing solely on the raw delivery of bits from one device to the next. It defines the electrical, mechanical, procedural, and functional specifications necessary for activating, maintaining, and deactivating the physical data transmission link between systems. The primary purpose of the physical layer is to provide a standardized interface to the transmission medium, ensuring reliable bit-level communication regardless of the underlying hardware variations. This enables interoperability among diverse networking equipment by specifying parameters such as voltage levels, connector types, cable specifications, and signal timing, while remaining agnostic to the meaning or structure of the data being transmitted from higher layers. For instance, it handles the conversion of digital data into analog signals suitable for propagation over media like twisted-pair cables or optical fibers, but does not interpret the bits as packets or frames. The concept of the physical layer originated during the development of the OSI model in the late 1970s, initiated by the International Organization for Standardization (ISO) to address the growing need for unified network architectures amid competing proprietary systems. This effort culminated in the formalization of the model as International Standard ISO 7498 in 1984, with the second edition as ISO/IEC 7498-1 in 1994, which established the physical layer as the foundational element for open systems interconnection. By isolating hardware-specific concerns at this lowest layer, the OSI framework facilitates modular design, allowing upper layers to focus on logical data handling without dependency on physical implementation details.

Position in OSI Model

The Open Systems Interconnection (OSI) reference model, defined by the International Organization for Standardization (ISO), organizes network functions into seven hierarchical layers to facilitate interoperable communications between systems. The physical layer occupies the lowest position as Layer 1, situated directly beneath the data link layer (Layer 2). In this structure, it serves as the foundational element, offering a transparent bit pipe that enables the transmission of raw bit streams over physical media without awareness of the content or structure of the data. The physical layer interacts with the data link layer by receiving protocol data units (PDUs) from it in the form of bit streams for transmission across the medium, and conversely, delivering received bit streams upward for frame assembly. Unlike higher layers, it performs no segmentation, reassembly, or error correction; its role is confined to pure physical transmission, ensuring the activation, maintenance, and deactivation of the connection. This demarcation allows upper layers to abstract away the specifics of the physical medium, focusing instead on logical data handling. The OSI model's layered architecture distinguishes between hop-by-hop operations at the lower layers and end-to-end services at the upper layers. Specifically, the physical layer manages hop-by-hop physical transmission, handling the local delivery of bits between adjacent nodes over the shared medium, while layers 3 through 7 address end-to-end delivery across the network. This separation promotes modularity, enabling independent development and standardization of each layer's functions. Originally published in 1984 as ISO 7498, the OSI model underwent revisions culminating in the 1994 edition (ISO/IEC 7498-1), which provided clarifications and ensured the model's applicability to diverse physical environments including wired, optical fiber, and wireless media. These updates maintained its relevance for modern networking standards.

Relations to Protocol Stacks

Internet Protocol Suite Mapping

In the TCP/IP model, commonly referred to as the Internet Protocol Suite, the physical layer is subsumed into the bottommost layer, known as the link layer or network access layer. This four-layer architecture—consisting of the application, transport, internet, and link layers—differs from the OSI model's seven layers by collapsing the physical and data link functionalities into a single layer to emphasize practical implementation over theoretical separation. The link layer handles both the transmission of raw bits over physical media and the framing of data for local network delivery, without prescribing specific physical standards beyond compatibility with the internet layer protocols like IP. The mapping of OSI physical layer functions to the TCP/IP link layer is evident in common implementations such as IP over Ethernet, where the Ethernet physical layer (PHY) manages signaling, cabling, and bit synchronization, while the data link control (MAC) sublayer integrates with IP packet encapsulation. Unlike the OSI model, which standardizes the physical layer independently, TCP/IP's less rigid layering leaves physical aspects to underlying technologies, resulting in no direct equivalent protocol suite for the physical layer itself. This integration allows flexibility for diverse media, such as twisted-pair copper or fiber optics, but requires adaptations like address resolution via ARP to bridge IP addressing with physical hardware. Historically, the physical aspects of TCP/IP evolved from the ARPANET's hardware foundations established in 1969, which used Interface Message Processors (IMPs) for bit transmission over leased telephone lines at 50 kbps. By 1983, ARPANET transitioned to TCP/IP as its standard protocol suite, inheriting and expanding upon these early physical interfaces to support heterogeneous networks. Since the 1990s, TCP/IP has achieved de facto dominance in global networking, rendering the physical layer largely implementation-specific and tied to vendor standards like IEEE 802.3 for Ethernet, rather than a universally standardized OSI-like abstraction. This pragmatic approach has facilitated the Internet's scalability, with physical layer details handled by local area network technologies rather than core protocol specifications.

Comparisons with Other Models

In the Department of Defense (DoD) model, developed in the 1970s as part of U.S. military standards for internetworking, physical layer functions such as bit transmission over media are integrated into the bottom Network Access layer rather than treated as a distinct layer, contrasting with the OSI model's separation of physical concerns. This four-layer structure—Network Access, Internet, Host-to-Host Transport, and Application—prioritizes simplicity for military packet-switched networks, folding hardware-specific transmission details into the access layer to support end-to-end connectivity without OSI's granular layering. Hybrid models like the IEEE 802 standard for local and metropolitan area networks (LAN/MAN) refine the physical layer by dividing it into sublayers, including the Physical Coding Sublayer (PCS) for encoding/decoding, Physical Medium Attachment (PMA) for signaling, and Physical Medium Dependent (PMD) for media interfacing, which provides modularity absent in the OSI's more monolithic Layer 1. This sublayering enables standardized adaptations for diverse media like twisted-pair or fiber, enhancing interoperability across Ethernet variants while aligning broadly with OSI principles but emphasizing practical implementation flexibility. In the Asynchronous Transfer Mode (ATM) protocol stack, the physical layer handles transmission over physical media. The ATM layer above it incorporates specific interfaces: the User-Network Interface (UNI) for endpoint-to-switch connections and the Network-Network Interface (NNI) for inter-switch links, allowing scalable cell-based multiplexing with varying header formats (e.g., UNI includes a Generic Flow Control field, while NNI expands the Virtual Path Identifier). This design supports both private and public networks by integrating physical signaling with adaptation layers, differing from OSI by embedding interface-specific adaptations directly into Layer 1 for broadband services. The 5G New Radio (NR) physical layer, defined in 3GPP Release 15 (completed in 2018), operates as the NR-PHY and introduces beamforming as a core mechanism for directional signal transmission in millimeter-wave bands, using procedures like beam sweeping and refinement to manage multiple antenna arrays and improve coverage in high-frequency environments. Unlike traditional OSI physical layers focused on static media, NR-PHY emphasizes dynamic beam management to counter path loss, with specifications for reference signals enabling UE-base station alignment in massive MIMO setups. Subsequent 3GPP releases have built upon this foundation; for instance, Release 17 (2022) introduced enhancements for reduced capability NR devices and extended MIMO operations, while Release 18 (frozen in 2024) further advanced beam management with AI/ML optimizations and support for integrated sensing and communication, as of November 2025. In modern paradigms like Software-Defined Networking (SDN) and Network Function Virtualization (NFV), introduced prominently in the 2010s, the physical layer undergoes abstraction where hardware elements are decoupled from software functions via virtualization layers, allowing programmable control of transmission resources without direct hardware dependencies. This shift, as outlined in ETSI NFV standards from 2012, enables slicing of physical infrastructure for virtual networks, contrasting OSI's hardware-centric Layer 1 by prioritizing orchestration and decoupling for cloud-native deployments.

Core Services and Functions

Bit-Level Transmission

The physical layer's primary function in bit-level transmission is to provide transparent delivery of raw bit streams from one data link entity to another across a physical connection, without interpreting or modifying the bits themselves. This service ensures the activation, maintenance, and deactivation of physical connections, enabling the reliable propagation of binary data (0s and 1s) over various media. In practice, this involves converting digital bit sequences into appropriate analog signals suitable for the transmission medium, such as voltage level shifts on electrical lines—for instance, using non-return-to-zero (NRZ) encoding where a high voltage represents a 1 and a low voltage represents a 0. The physical layer supports different operational modes to accommodate diverse communication needs: simplex for unidirectional transmission, half-duplex for bidirectional communication using the same channel alternately, and full-duplex for simultaneous bidirectional exchange on separate channels. Transmission occurs over two main categories of physical media: guided, which uses physical conduits to direct signals, and unguided, which propagates signals through free space. Guided media include twisted-pair copper cables for short-range local networks, coaxial cables for moderate distances, and optical fiber for high-speed, long-haul connections. Unguided media, such as radio waves, enable wireless transmission without physical wiring, commonly used in mobile and satellite systems. Bit rates vary significantly depending on the medium and technology; for example, early Ethernet over twisted pair operates at 10 Mbps, while modern optical fiber implementations support up to 400 Gbps for data center interconnects. Under ideal conditions, the physical layer assumes error-free bit transmission, delivering bits exactly as received without detection or correction of impairments like noise, attenuation, or interference—these are managed by higher layers such as the data link layer. In real-world scenarios, however, channel distortions can introduce bit errors, necessitating error control mechanisms above the physical layer to ensure overall reliability. The fundamental relationship governing bit transmission is the bit rate R_b, defined as the number of bits transmitted per second, given by R_b = \frac{1}{T_b} where T_b is the duration of a single bit. This equation highlights how shorter bit durations enable higher rates but increase susceptibility to timing errors and noise.

Synchronization and Timing

In the physical layer, synchronization and timing ensure that transmitters and receivers maintain aligned bit streams to prevent data errors during transmission. Clocking methods vary based on the network architecture: synchronous systems use a shared clock signal distributed across devices for precise coordination, while asynchronous methods employ start and stop bits to frame individual characters, allowing independent clocking at each end. Plesiochronous operation, common in near-synchronous environments like digital hierarchies, permits slight frequency differences between clocks, with buffering to absorb variations without losing data. Timing recovery techniques enable receivers to extract the embedded clock from the data signal, crucial for self-clocking in the absence of a dedicated clock line. Manchester encoding achieves this by incorporating a transition in the middle of each bit period—high-to-low for a logical 0 and low-to-high for a 1—providing predictable edges for synchronization without DC bias accumulation. In multi-lane links, such as those in high-speed serial interfaces, jitter (short-term clock variations) and skew (lane-to-lane timing misalignment) are managed through elastic buffers and deskew circuits, which compensate for up to 180 ns of skew variation per IEEE specifications to maintain aggregate data integrity. Standards like IEEE 802.3 define bit synchronization via preamble sequences, consisting of seven octets of alternating 1s and 0s (10101010 pattern) followed by a start frame delimiter, which allows receivers to lock phase-locked loops (PLLs) onto the incoming signal before data payload arrival. Clause 90 of IEEE 802.3 provides Ethernet support for time synchronization protocols, such as PTP, by specifying timestamp capture at the media-independent interface to account for PHY delays in 40G and 100G systems. In post-2020 high-speed Ethernet beyond 400G, such as IEEE 802.3ck and 802.3df, timing challenges intensify due to PAM4 modulation's sensitivity to inter-symbol interference, necessitating integrated forward error correction (FEC) like Reed-Solomon codes to achieve target bit error rates below 10^{-13}.

Internal Components

Physical Coding Sublayer

The Physical Coding Sublayer (PCS), as defined in standards such as IEEE 802.3 for Ethernet implementations of the OSI physical layer, serves as the upper sublayer within the physical layer, primarily responsible for transforming logical bit streams into encoded symbols suitable for transmission while ensuring signal integrity and receiver synchronization. It operates independently of the specific physical medium, focusing on digital processing to mitigate issues like signal distortion and timing errors. In standards such as IEEE 802.3 for Ethernet, the PCS interfaces with the Media Independent Interface (MII) or its variants, receiving data from the MAC layer and preparing it through encoding and scrambling before handover to the Physical Medium Attachment (PMA) sublayer. Key functions of the PCS include line coding, which maps uncoded bits to coded symbols to achieve direct current (DC) balance—preventing baseline wander in AC-coupled systems—and to enable clock recovery by ensuring sufficient bit transitions for the receiver's phase-locked loop. For instance, the 8b/10b line code, specified in IEEE 802.3 Clause 36 for Gigabit Ethernet PHYs like 1000BASE-X, encodes 8-bit data words plus a disparity bit into 10-bit symbols, maintaining running disparity for DC balance and providing sufficient transitions for reliable clock extraction. Similarly, the 64b/66b code, defined in Clause 49 for 10 Gb/s and higher rates (e.g., 10GBASE-R), groups 64 uncoded bits into 66-bit blocks prefixed by a 2-bit synchronization header (either 01 for data or 10 for control), which aids in block alignment and error detection while supporting clock recovery through regular sync patterns. The coding rate for such schemes is given by \text{Coding rate} = \frac{k}{n} where k represents the number of uncoded bits and n the number of coded bits or symbols; for 64b/66b, this yields $64/66 \approx 0.97, introducing minimal overhead compared to 8b/10b's $8/10 = 0.8. Another critical PCS function is scrambling, which applies a self-synchronizing polynomial (e.g., x^{58} + x^{39} + 1 in 64b/66b Ethernet) to the bit stream, randomizing the data to eliminate long runs of identical bits that could generate discrete spectral lines, thereby reducing electromagnetic interference and improving signal spectrum flatness for better transmission efficiency. In IEEE 802.3 Ethernet, scrambling is applied post-encoding in the transmit direction and reversed in receive, with the PCS also incorporating basic error detection through invalid sync headers or disparity violations, often augmented by parity bits in block structures for enhanced reliability. A representative example of advanced PCS implementation is found in 50 Gb/s Ethernet as defined in IEEE 802.3cd (2018), where the PCS employs 64b/66b encoding on multiple lanes, followed by forward error correction (FEC) with Reed-Solomon codes that include parity bits for error detection and correction, before symbol mapping to four-level pulse-amplitude modulation (PAM-4) in the PMA; this supports aggregate rates up to 200 Gb/s while maintaining low bit error rates (target < 10^{-13} post-FEC). Recent amendments like IEEE 802.3df (2024) extend these to 800 Gb/s using advanced encoding such as 256b/257b. These mechanisms collectively ensure the PCS delivers a reliable, media-agnostic interface, with its role in synchronization briefly supporting timing recovery processes in the broader physical layer.

Physical Medium Dependent Sublayer

The Physical Medium Dependent (PMD) sublayer serves as the interface between the Physical Medium Attachment (PMA) sublayer and the actual transmission medium, defining the physical and electrical or optical characteristics required for transmitting and receiving signals over specific media such as twisted-pair copper or optical fiber. It specifies the transmitter and receiver components, including their optical or electrical signaling parameters, to ensure reliable bit transmission while adapting to the medium's properties like impedance, wavelength, or attenuation. For instance, in copper-based Ethernet, the PMD incorporates transceivers connected via RJ-45 connectors for twisted-pair cabling, handling differential signaling and signal conditioning to mitigate noise over distances up to 100 meters. In optical implementations, it utilizes pluggable modules like Small Form-factor Pluggable (SFP) transceivers, which integrate laser diodes for transmission and photodetectors for reception, enabling hot-swappable connectivity to fiber optic cables. Media adaptations in the PMD sublayer are tailored to the propagation characteristics of the chosen medium, particularly for optical fiber where signal integrity depends on wavelength selection and power budgeting. For single-mode fiber (SMF), common operating wavelengths include 1310 nm for shorter reaches (up to 10 km) and 1550 nm for longer distances (up to 40 km or more), as these minimize attenuation and dispersion in silica-based fibers. The PMD defines transmitter output power levels, typically ranging from -9.5 dBm to 0.5 dBm at 1310 nm for various Ethernet variants, and receiver sensitivity thresholds, such as -14 dBm, to accommodate attenuation budgets of 10-20 dB depending on the Ethernet variant. These parameters ensure the optical signal-to-noise ratio remains sufficient for error-free detection, with the PMD also specifying connector types like LC for duplex fiber links. Key standards governing the PMD sublayer include IEEE 802.3ba-2010, which defines PMD specifications for 40 Gb/s and 100 Gb/s Ethernet over both multimode and single-mode fiber, incorporating multi-lane interfaces for parallel transmission to achieve aggregate rates. For example, 40GBASE-LR4 uses four 10 Gbps lanes at 1310 nm wavelength division multiplexing (WDM) on SMF, with PMD requirements for lane alignment and crosstalk mitigation. To maintain signal integrity over distance, especially in copper backplanes or longer fiber spans, the PMD integrates equalization techniques such as continuous-time linear equalization (CTLE) and decision feedback equalization (DFE), compensating for inter-symbol interference and insertion loss up to 30 dB at Nyquist frequency. Advancements in PMD for higher speeds address the limitations of direct-detection optics, incorporating coherent detection in standards like the Optical Internetworking Forum's (OIF) 400ZR Implementation Agreement (2022), which specifies a 400 Gb/s coherent PMD using dual-polarization 16-QAM modulation over SMF up to 120 km without amplification. This coherent PMD employs digital signal processing (DSP) for phase recovery and polarization demultiplexing at the receiver, enabling higher spectral efficiency and reach compared to intensity-modulated direct-detection schemes. Emerging research explores quantum-safe adaptations in the physical layer, such as integrating quantum key distribution (QKD) protocols with PMD interfaces to detect eavesdropping via fiber perturbation monitoring, though standardized implementations remain in development.

Key Technologies and Standards

Ethernet Physical Transceivers

Ethernet physical transceivers, integral to the physical layer (PHY) of IEEE 802.3 Ethernet standards, have evolved significantly since the introduction of 10BASE5 in 1980, which utilized thick coaxial cable for 10 Mbps transmission over distances up to 500 meters. This early implementation relied on Manchester encoding and a bus topology, marking the foundation of wired Ethernet PHYs. Over decades, advancements progressed through twisted-pair copper (e.g., 10BASE-T in 1990) and fiber optics, culminating in high-speed variants like 800GBASE-R as defined in the IEEE 802.3df-2024 amendment, which supports 800 Gb/s using eight lanes of 106.25 Gb/s PAM4 signaling for enhanced spectral efficiency. These evolutions reflect a shift from simple amplitude modulation to multilevel signaling, enabling exponential bandwidth growth while maintaining compatibility with existing infrastructure. Common transceiver types include pluggable modules such as Small Form-factor Pluggable (SFP) for 1 Gb/s and 10 Gb/s applications, and Quad Small Form-factor Pluggable (QSFP) variants like QSFP28 for 100 Gb/s and QSFP-DD for 400 Gb/s and beyond, adhering to Multi-Source Agreements (MSAs) integrated into IEEE 802.3 specifications. These hot-swappable modules facilitate flexible media attachment, supporting both copper and fiber interfaces. Auto-negotiation, defined in IEEE 802.3 Clause 28, enables devices to automatically select the highest common speed and duplex mode (e.g., 10/100/1000 Mb/s full/half-duplex) via Fast Link Pulses, reducing configuration errors and optimizing link performance. Performance characteristics vary by medium and standard: copper-based PHYs like 10GBASE-T achieve 100-meter reaches over Category 6A cabling, while fiber optics extend to 10 kilometers for 10GBASE-LR using single-mode fiber at 1310 nm wavelength. Power consumption has trended downward; for example, QSFP28 modules for 100 Gb/s typically consume 3.5 W, compared to around 1 W for 1 Gb/s SFP modules, driven by process improvements and architectural efficiencies. The IEEE 802.3az-2010 amendment introduced Energy Efficient Ethernet (EEE), which reduces power by over 50% during low-utilization periods through low-power idle modes in PHYs for 100BASE-TX, 1000BASE-T, and 10GBASE-T, addressing the growing energy demands of always-on networks. In data centers, multi-rate PHYs support seamless operation across speeds such as 1 Gb/s, 2.5 Gb/s, 5 Gb/s, and 10 Gb/s over existing cabling (e.g., Cat5e for 2.5GBASE-T per IEEE 802.3bz-2016), minimizing upgrade costs and enabling gradual migration to higher bandwidths without full infrastructure overhauls. These PHYs leverage unified encoding and auto-negotiation extensions to ensure backward compatibility, optimizing for dense, high-throughput environments like hyperscale computing.

Wireless PHY Implementations

Wireless physical layer (PHY) implementations differ fundamentally from wired counterparts by relying on unguided electromagnetic wave propagation through air or space, necessitating robust techniques to handle dynamic channel conditions such as path loss and Doppler shifts. These designs emphasize modulation, coding, and signal processing to achieve reliable bit transmission over varying distances and environments, often incorporating orthogonal frequency-division multiplexing (OFDM) to combat frequency-selective fading. A prominent example is the IEEE 802.11ax standard, released in 2021 and marketed as Wi-Fi 6, which enhances spectral efficiency in dense environments through multi-user multiple-input multiple-output (MU-MIMO). MU-MIMO allows access points to simultaneously serve up to eight devices using spatial streams, improving throughput by a factor of up to four compared to prior single-user MIMO implementations. Subsequent to Wi-Fi 6, the IEEE 802.11be amendment (Wi-Fi 7), published in 2025, introduces enhancements including 320 MHz channel widths primarily in the 6 GHz band, 4096-QAM modulation for 12 bits per symbol, and multi-link operation (MLO) to aggregate bands for throughputs up to 46 Gbps. Similarly, the 5G New Radio (NR) PHY, specified by 3GPP in Release 15 (2018), employs OFDM with flexible numerology and massive MIMO beamforming to support high data rates and low latency across sub-6 GHz and millimeter-wave bands. Beamforming in 5G NR directs signals toward user equipment using precoding matrices, mitigating interference and extending coverage in non-line-of-sight scenarios. Modulation schemes in these wireless PHYs leverage quadrature amplitude modulation (QAM) variants, ranging from 16-QAM for robustness in noisy channels to 1024-QAM in 802.11ax for peak spectral efficiency exceeding 10 bits per symbol. Channel coding employs low-density parity-check (LDPC) codes in both Wi-Fi 6 and 5G NR for data channels, offering near-Shannon-limit performance with iterative decoding, while 5G NR uses polar codes for control information to ensure low error rates at short block lengths. Turbo codes, historically used in earlier cellular standards, have been largely supplanted by LDPC in 5G for downlink data due to superior performance in high-throughput scenarios. Wireless PHYs face inherent challenges like multipath fading, where signals arrive via multiple paths causing destructive interference, addressed through OFDM's subcarrier orthogonality and cyclic prefixes. Interference mitigation often involves dynamic frequency selection or hopping, as in Wi-Fi's adaptation to crowded bands, while spectrum allocation for 802.11 standards includes unlicensed 2.4 GHz (with 20-40 MHz channels prone to Bluetooth overlap), 5 GHz, and 6 GHz bands (offering up to 160 MHz channels for higher capacity). In 5G NR, millimeter-wave (mmWave) PHY extensions, operational up to 100 GHz since post-2020 deployments, incorporate hybrid beamforming with large antenna arrays (up to 256 elements) to overcome severe path loss and enable gigabit speeds over short ranges. These designs use finer subcarrier spacings (e.g., 120 kHz) and advanced equalization to handle oxygen absorption and rain attenuation at frequencies like 28 GHz. Satellite PHY evolutions, such as those in Starlink's low-Earth orbit constellation launched since 2019, adapt terrestrial wireless principles to space-to-ground links using phased-array antennas for beam tracking and OFDM-based modulation in the Ku-band (10.7-12.7 GHz). This implementation supports adaptive coding and modulation to counter varying link budgets from orbital motion, achieving latencies under 50 ms with LDPC error correction for reliable broadband delivery.

References

  1. [1]
    What Is the OSI Model? | IBM
    The physical layer comprises the physical network components responsible for transmitting raw data—in the form of “bits,” or strings of 1s and 0s—between ...
  2. [2]
    What Is the OSI Model? - 7 OSI Layers Explained - Amazon AWS
    The OSI model is a conceptual framework dividing network communications into seven layers, providing a universal language for computer networking.What Is Osi Model? · What Is The Osi Model? · Why Is The Osi Model...
  3. [3]
    What is the OSI Model? 7 Network Layers Explained - Fortinet
    The physical layer involves the physical equipment that transfers data, like switches and cables. In this layer, the data is converted into strings of 1s and 0s ...Osi Model Explained · Layer 4 - Transport Layer · Layer 1 - Physical Layer<|control11|><|separator|>
  4. [4]
    What is OSI Model | 7 Layers Explained - Imperva
    Functions of the Physical Layer include the modulation, bit synchronization, and transmission of raw binary data over the physical medium. Technologies such ...Transmission Control Protocol · What is Broken Object Level... · What is HTTP/2
  5. [5]
    Windows network architecture and the OSI model - Microsoft Learn
    Jan 31, 2025 · The physical layer carries the signals for all of the higher layers. In Windows, the network interface card (NIC) implements the physical layer, ...
  6. [6]
    Network Hierarchy (OSI Model) | Field Network Basics - Keyence
    In particular, the physical layer defines the voltage level, switching timing, transmission rate, transmission distance, and connector shapes. Data link layer.
  7. [7]
    What is Layer 1 of The OSI Model: Physical Layer? - Infoblox
    The physical layer defines the relationship between a device and a transmission medium, such as a copper or optical cable.Missing: IEC 7498-1
  8. [8]
    IEEE 802.3-2022 - IEEE SA
    Jul 29, 2022 · This amendment to IEEE Std 802.3-2018 adds Physical Layer (PHY) specifications and management parameters for 50 Gb/s, 200 Gb/s, and 400 Gb/s ...
  9. [9]
    P802.11 - IEEE SA
    This standard defines one medium access control (MAC) and several physical layer (PHY) specifications for wireless connectivity for fixed, portable, and moving ...
  10. [10]
    Physical Layer OSI Model: Guide to Layer 1 Networking - JumpCloud
    Aug 4, 2025 · The Physical Layer (Layer 1) is the foundation of network communication, moving raw bits between devices, and is the first and lowest layer of ...Osi Model Foundation · How It Works · Physical Layer Devices
  11. [11]
    OSI: The Internet That Wasn't - IEEE Spectrum
    Jul 29, 2013 · A comprehensive set of standards for computer networks called Open Systems Interconnection, or OSI. Its architects were a dedicated group of computer industry ...
  12. [12]
    [PDF] ISO/IEC 7498-1 - Ecma International
    Jun 15, 1996 · 8. As shown in Figure 1, the physical media for Open Systems Interconnection provides the means for the transfer of information between open ...
  13. [13]
    RFC 894: A Standard for the Transmission of IP Datagrams over Ethernet Networks
    ### Summary: Transmission of IP over Ethernet (RFC 894)
  14. [14]
    An Overview of TCP/IP Protocols and the Internet
    Jul 21, 2019 · The ARPANET started with four nodes in 1969 and grew to just under 600 nodes before it was split in 1983. The NSFNET also started with a modest ...
  15. [15]
    A Brief History of the Internet - Internet Society
    TCP/IP was adopted as a defense standard three years earlier in 1980. This enabled defense to begin sharing in the DARPA Internet technology base and led ...Missing: physical | Show results with:physical
  16. [16]
    [PDF] TCP/IP Tutorial and Technical Overview - IBM Redbooks
    where ARP cannot be implemented in the physical layer as described previously. Therefore, every host, upon initialization, must register with an ARP server ...
  17. [17]
    DoD Four-Layer Model - freesoft.org
    The Department of Defense Four-Layer Model was developed in the 1970s for the DARPA Internetwork Project that eventually grew into the Internet.
  18. [18]
    DoD or TCP/IP Model and the CCNA & Network+ Exams
    Jun 25, 2010 · The TCP/IP model, sometimes referred to as the Department of Defense (DoD) Model, is a four-Layer model that was developed in the early 1970s ...Missing: military standards
  19. [19]
    Ethernet Physical Layer Standards - NetworkAcademy.IO
    If the link is IEEE802.3u FastEthernet for example, the 1s and 0s are represented as electrical signals, if for example fiber optic link is used, the 1s and 0s ...
  20. [20]
    A Brief Overview of ATM: Protocol Layers, LAN Emulation, and ...
    For the UNI, the routing field contains 24 bits and thus the interface can support over 16 million sessions. At the NNI, the field contains 28 bits, allowing ...
  21. [21]
    [PDF] TS 138 300 - V15.3.1 - 5G; NR - ETSI
    - Functions for Radio Resource Management: Radio Bearer Control, Radio Admission Control, Connection. Mobility Control, Dynamic allocation of resources to UEs ...
  22. [22]
    [PDF] A Tutorial on Beam Management for 3GPP NR at mmWave ... - arXiv
    Nov 4, 2019 · Sec. III provide basic information on the 3GPP. Release 15 frame structure for NR, and presents the candidate. DL and UL measurement signals ...
  23. [23]
    [PDF] Software-Defined Network Function Virtualization: A Survey - People
    By decoupling the network functions from the underlaying hardware appliances, NFV provides flexible provisioning of software-based network functionalities on ...
  24. [24]
    5. Timing, Clocking,and Synchronization in the T-carrier System - T1
    Three major types of timing are used on networks: asynchronous, synchronous, and plesiochronous. All three terms derive from the Greek word kronos , meaning ...
  25. [25]
    [PDF] Physical Layer – Part 2 Data Encoding Techniques
    Synchronization – with a predictable transition per bit time the receiver can “synch” on the transition [self- clocking]. No d.c. component. Error detection – ...
  26. [26]
    [PDF] Testing 40 and 100 GBPS Ethernet - Xena Networks
    Physical Coding Sub-layer (PCS). Testing the PCS layer involves introducing lane swapping and lane skew. Measuring the ability of the DUT to manage the ...<|separator|>
  27. [27]
    [PDF] Time Synchronization Clarifications for 802.3dj - IEEE 802
    Jul 1, 2024 · To avoid these problems, Clause 90 presents a simpler method: • calculate timestamps at the MII, which is a smooth, continuous interface. • ...
  28. [28]
    [PDF] 100G and 400G Ethernet and general DataCom roadmap ...
    This results in smaller vertical eye openings, higher sensitivity to noise. ▫ Forward Error Correction (FEC) is needed to improve BER performance of the link. ▫ ...<|separator|>
  29. [29]
    [PDF] 64b/66b PCS - IEEE 802
    • This is a high level overview – for details use IEEE 802.3 Clause. 49. Page 3. La Jolla, CA. July 10-14, 2000. 64b/66b Coding Update. IEEE 802.3ae. Task Force.
  30. [30]
    [PDF] 40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview
    Jun 17, 2010 · This white paper provides an overview of the IEEE Std 802.3ba-2010 40 Gb/s and 100 Gb/s Ethernet standard and the underlying technologies. Page ...
  31. [31]
    [PDF] Implementation Agreement 400ZR | OIF
    Nov 3, 2022 · The Implementation Agreement 400ZR is an agreement created and approved by the OIF for a 400ZR Coherent Optical interface.
  32. [32]
    [PDF] 75. Physical Medium Dependent (PMD) sublayer and ... - IEEE 802
    Jul 17, 2008 · The electrical specifications of the PMD service interface (TP1 and TP4 for the downstream channel and. TP5 and TP8 for the upstream channel) ...
  33. [33]
    [PDF] Physical Layer Aspects of Quantum Communications: A Survey - arXiv
    Jul 12, 2024 · This technology enables the integration of various quantum components such as single-photon sources, single-photon detectors, and quantum gates ...
  34. [34]
    Ethernet Through the Years: Celebrating the Technology's 50th Year ...
    Standards development saw six speeds of Ethernet added to IEEE 802.3 in the first 30 years, raising the speed to 100 Gb/s in 2013, but in just five more ...
  35. [35]
    802.3df Jul 2022 - IEEE 802
    Jul 22, 2022 · Baseline proposals for 800 GbE RS/MII, Extender/XS, Time Sync and PMA, using 100G/lane signaling 06-July-2022 (255 k), Gary Nicholl Arthur ...
  36. [36]
    [PDF] 800G Specification - Ethernet Technology Consortium
    Mar 10, 2020 · References are made throughout this document to IEEE 802.3-2018 Ethernet Access Method and Physical Layer [base standards], as well as 802.3ck ...Missing: evolution 10BASE5<|control11|><|separator|>
  37. [37]
    Cisco 40GBASE QSFP Modules Data Sheet
    ... QSFP 40G ports for superior performance, quality, and reliability. ○ High-speed electrical interface compliant to the IEEE 802.3ba standard. ○ QSFP Form ...
  38. [38]
    [PDF] SFF-8679 Specification for QSFP+ 4X Hardware and Electrical ...
    Mar 18, 2025 · SFF-8679 defines the contact pads, electrical, power supply, ESD and thermal characteristics of the pluggable QSFP+ module or cable plug.
  39. [39]
    [PDF] 802.3ap Auto-Negotiation with Clause 28 State Machines - IEEE 802
    Jul 10, 2004 · 802.3ap auto-negotiation uses Clause 28 state machines, which are robust and established for copper technologies, and can negotiate multiple ...
  40. [40]
    Ethernet Cable Categories Explained: A Brief History - Fluke Networks
    Feb 24, 2022 · The first version, 10BASE5, featured extremely stiff cable nearly ... In the late 1980s, the development of the Ethernet hub, and later ...
  41. [41]
    Optics vs Copper: Debunking Myths and Understanding the Real ...
    Apr 17, 2025 · For example, a typical 10 Gbps copper Ethernet link (such as Cat 6A) over 100 meters can consume approximately 5 to 8+ watts per port, while an ...Missing: reach | Show results with:reach
  42. [42]
    IEEE 802.3az-2010 - IEEE SA
    This amendment to IEEE Std 802.3-2008 specifies changes to several existing physical layers to enable energy-efficient operation of Ethernet.
  43. [43]
    IEEE P802.3az Energy Efficient Ethernet Task Force - IEEE 802
    Jun 9, 2018 · The work of the P802. 3az Energy Efficient Ethernet Task Force is now complete with the approval of IEEE Std 802.3az-2010 at the September 2010 ...<|separator|>
  44. [44]
    [PDF] Multi Rate PHY - IEEE 802
    Multi-Rate PHY shall guarantee operation at:​​ – 2.5Gb/s on 100m Cat5e or better – 5Gb/s on 100m Cat6 or better. Nominal ANEXT improvement maybe required – 10G ...
  45. [45]
    Ethernet PHY Transceivers | Connecting Infrastructure with Broadest ...
    Marvell transceivers enable optimized form factors with multiple port and cable options, efficient power consumption and simple plug-and-play functionality.
  46. [46]
    Designing for the future: the 5G NR physical layer - Ericsson
    Jul 24, 2017 · The spectrum of OFDM signal decays rather slowly outside the transmission bandwidth. In order to limit out-of-band emission, the spectrum ...<|control11|><|separator|>
  47. [47]
    [PDF] ETSI TS 138 211 V18.2.0 (2024-05)
    ... 3GPP TS 38.211 version 18.2.0 Release 18. Intellectual Property Rights ... The present document describes the physical channels and signals for 5G-NR.
  48. [48]
    802.11ax-2021 | IEEE Standard | IEEE Xplore - IEEE Xplore
    May 19, 2021 · The purpose of this standard is to provide wireless connectivity for fixed, portable, and moving stations within a local area.
  49. [49]
    [PDF] Multi-User MIMO in WiFi 6 - Arista
    MU-MIMO enables a multi-antenna AP to simultaneously communicate with multiple clients, thereby increasing system throughput. The IEEE 802.11ac standard ...
  50. [50]
    Specification # 38.211 - 3GPP
    Apr 13, 2017 · 38.211. Title: NR; Physical channels and modulation. Status: Under change control. Type: Technical specification (TS). Initial planned Release ...
  51. [51]
    [PDF] Understanding 5G Beam Management - MathWorks
    A key feature of the 5G-New Radio (NR) design is its ability to operate in two different frequency ranges: sub-6 GHz and millimeter wave (mmWave).<|separator|>
  52. [52]
    Comparing WiFi & 5G LDPC Architecture - AccelerComm
    WiFi has been using LDPC codes for the error correction for many years. And now 5G new radio has adopted them for cellular communication as well.
  53. [53]
    Overview of the challenges and solutions for 5G channel coding ...
    The main channel code contenders for 5G URLLC are Turbo codes, LDPC codes, Polar codes and Rateless codes. ... The proposed scheme outperforms single LDPC codes ...
  54. [54]
    Wi-Fi: Overview of the 802.11 Physical Layer and Transmitter ...
    This primer provides a general overview for each of the 802.11 standards, their PHY layer characteristics and their testing requirements.
  55. [55]
    [PDF] Understanding mmWave for 5G Networks 1 - 5G Americas
    Dec 1, 2020 · 5G New Radio (NR) is the first mobile technology generation to make use of the mmWave spectrum. Although it has been years in the making, its ...
  56. [56]
    [PDF] Signal Structure of the Starlink Ku-Band Downlink
    Abstract—We develop a technique for blind signal identifica- tion of the Starlink downlink signal in the 10.7 to 12.7 GHz band and present a detailed ...