Fact-checked by Grok 2 weeks ago
References
-
[1]
population equivalent - European Environment Agency (EEA)One population equivalent (pe) means the organic biodegradable load having a five-day biochemical oxygen demand (BOD5) of 60 g of oxygen per day.
-
[2]
[PDF] Classification of Wastewater Treatment Plants - Maricopa County"Population Equivalent" means the population which would contribute an equal amount of biochemical oxygen demand (BOD) computed on the basis of 0.17 pounds of ...
-
[3]
Directive - 91/271 - EN - EUR-Lex### Summary of 'Population Equivalent' (p.e.) from Directive 91/271/EEC
-
[4]
[PDF] wastewater operator's formula sheet 2022Population. Equivalent, (PE). = Daily Loading,lbs. (PE factor,daily lbs/person). Detention. Time,. (hrs). = (Tank Volume, ft3)(7.48 gal. ft3. ⁄ )(24 hrs day.
-
[5]
The Population Equivalent of Certain Industrial Wastes - jstortion, gives a total of 600,728, compared wTith a total population equiva lent, as determined from the B.O.D. of the sewage for 1933, of 587,000. With the advent ...
-
[6]
[PDF] A BRIEF HISTORY OF WASTEWATER TREATMENTWastewater treatment history is divided into five periods: early history, the roman period, the sanitary dark age, the industrial age, and the age of ...
-
[7]
[PDF] THE 12TH IAWPRC BIENNIAL INTERNATIONAL CONFERENCESep 20, 1984 · ... (inhabitant equivalent) = 54 g BOD/day; i.e.(mun.)= municipal; i.e.(ind.)= industrial. OX= oxidation ditch, AS= activated sludge, TF ...
-
[8]
Directive - EU - 2024/3019 - EN - EUR-LexDec 12, 2024 · Directive (EU) 2024/3019 of the European Parliament and of the Council of 27 November 2024 concerning urban wastewater treatment (recast)
-
[9]
40 CFR Part 133 -- Secondary Treatment Regulation - eCFR§ 133.100 Purpose. This part provides information on the level of effluent quality attainable through the application of secondary or equivalent treatment.133.102 · Title 40 · 133.103 · 133.105
-
[10]
Urban Wastewater (Nutrient - Sensitive Areas) Regulations 2025Aug 22, 2025 · (a) a population equivalent of one (one p.e.) means the organic ... 91/271/EEC (the Urban Wastewater Treatment Directive) and Directive No.
- [11]
- [12]
-
[13]
[PDF] Biochemical Oxygen Demand (BOD) and Carbonaceous BOD ...The purpose of the biochemical oxygen demand (BOD5) test is to measure the potential of wastewater and other waters to deplete the oxygen level of receiving ...
- [14]
-
[15]
Under Indian conditions, the average per capita contribution of BOD isJan 14, 2022 · The average BOD of domestic sewage is 80 grams/capita/day. ∴ Option 4 is the most appropriate answer. Download Soln PDF · Share on Whatsapp.
-
[16]
Population Equivalent - MADE EASYSep 10, 2024 · ... sewage is called population equivalent of industrial sewage. Industrial wastewater are generally compared with per capita normal domestic ...
-
[17]
Population equivalent - Coastal WikiApr 16, 2013 · ... Directive 91/271/EEC as the organic biodegradable load having a five-day biochemical oxygen demand (BOD5) of 60 g of oxygen per day.
- [18]
-
[19]
Guide to Chemical Oxygen Demand (COD) TestingThe COD test takes only a few hours to complete. If BOD was always used, a problem with the treatment process wouldn't be detected until five days later. This ...
-
[20]
DE19630831C2 - Plant wastewater treatment plant with horizontal ...... wastewater with the same degree of pollution. 1 PE corresponds to a load of 60 g BOD 5 (or approx. 150 g COD) per day (DIN 4045). According to K. and KR ...
-
[21]
Treatment of sidestream dewatering liquors from thermally ...Jan 17, 2020 · ... (1 PE equal to 150 g COD) in the south-eastern part of the Netherlands (Van Veldhoven et al. 2018). Waterboard De Dommel made a strategic ...
-
[22]
Comparison between the COD/BOD Ratios of Treatment Plantstypical COD/BOD (5) ratio of domestic wastewaters is usually in the range 1.25 to 2.5. However, for treated effluents, it ranged from 9.767 to 11.62 and 3.357 ...
-
[23]
[PDF] Recommended Standards for Wastewater FacilitiesIn 1947, a "Committee on Development of Uniform Standards for Sewage Works" was created by the group now known as the Great Lakes - Upper Mississippi River ...
-
[24]
Onsite Sewage Treatment and Disposal Systems: NitrogenThe US EPA (1992) estimated that one person typically discharges 11.2 grams of total N per day (Table 1). Of total N, approximately 8.7 grams (78%) comes from ...Missing: population equivalent
-
[25]
[PDF] Phosphorus - Hydro InternationalOne person produces an average of 2 g of phosphorus a day which ends up at municipal treatment works. At the end of the treatment process, municipal ...Missing: population | Show results with:population
-
[26]
BOD, COD, and TOC - The Wastewater BlogJan 13, 2019 · In the case of biodegradable organics, the COD is normally in the range of 1.3 to 1.5 times the BOD.
-
[27]
[PDF] Code of Practice for Domestic Waste Water Treatment SystemsMar 6, 2021 · equivalent a measurement of the organic biodegradable load. A population equivalent of 1 (1 PE) means the organic biodegradable load having.
-
[28]
Municipal Sewage - an overview | ScienceDirect Topics... 150–200 l per day per capita for domestic wastes only, with at least as much again from other sources). •. the concentration of impurities in the influent ...
-
[29]
[PDF] Administrative Package Cover PageDec 31, 2024 · ... BOD5 concentration is 250-300 mg/L. The design BOD5 concentration of the influent from the collection system is 200 mg/L. Note: Permits that ...
-
[30]
A comparative LCA of three WWTPs in a tourist areaMar 10, 2023 · Wastewater treatment plants (WWTPs) located in tourist areas generally suffer from the seasonal increase in wastewater flow-rate and associated ...
-
[31]
Contextualizing Inflow and Infiltration Within the Streamflow Regime ...Jan 7, 2022 · We find that inflow and infiltration of fresh water into sanitary-sewer pipes commonly represent 20%–40% of the flow in the pipes.Missing: domestic | Show results with:domestic
-
[32]
[PDF] Guidance for Population Equivalent (PE) CalculationsOne P.E. equals 100 gallons/day, 0.20 lb SS/day, or 0.17 lb BOD/day wastewater discharge, whichever is largest. Typically, 100 gallons/day/P.E. applies to ...
-
[33]
Understanding Laboratory Wastewater Tests: I. Organics (BOD ...The BOD test is also known as “BOD5” since it is based on the accurate measure of DO (dissolved oxygen) at the beginning and end of a five-day period in which ...
-
[34]
Reviewing textile wastewater produced by industries: characteristics ...Mar 11, 2022 · The BOD/COD ratio for composite textile wastewater is approximately 0.25. This indicates that wastewater contains a large amount of non- ...
-
[35]
[PDF] Development Document for Dairy Products Processing Effluent ...BOD:COD ratio for raw effluents reported from all sources is 0.07 to 1.03. The mean for identified plants is 0.57. This figure can be used as a conversion ...
-
[36]
[PDF] WAS TEWATER TREATMENT MANUALSA population equivalent of 1(1 p.e.) means the organic biodegradable load having a ... This means domestic wastwater or the mixture of domestic wastewater with ...
-
[37]
Pretreatment Standards and Requirements-Applicability | US EPAAug 28, 2025 · Industrial Wastewater · Municipal Wastewater · Combined Sewer Overflows (CSOs) · Sanitary Sewer Overflows (SSOs) · Peak Flows · Integrated ...Missing: reduction population equivalent
-
[38]
[PDF] Best Available Techniques (BAT) Reference Document for Common ...Jun 9, 2019 · This publication is a Science for Policy report by the Joint Research Centre (JRC), the European Commission's science and knowledge service.
-
[39]
Secondary Treatment Standards | US EPASep 11, 2025 · EPA establishes secondary treatment standards for publicly owned treatment works (POTWs), which are minimum, technology-based requirements for municipal ...Missing: population | Show results with:population
- [40]
-
[41]
How should BOD5 be used in biological wastewater treatment?The BOD5 measure is very widely used, in particular to check the regulatory conformity of effluent from urban and industrial wastewater treatment plants.
-
[42]
[PDF] Chapter 5 Wastewater Flows and Loads - Dayton, OregonThe per capita flow rate multiplied by the projected equivalent population equals the residential, commercial, and industrial sanitary component of the flow ...
-
[43]
[PDF] NPDES PERMIT NO. NM0020681 FACT SHEETDec 1, 2021 · Pollutants with limits established in this Chapter are BOD5,. TSS and pH. BOD5 limits of 30 mg/l for the 30-day average and 45 mg/l for the 7- ...Missing: equivalent | Show results with:equivalent
-
[44]
Model-based dynamic simulation study to boost the WWTP ...This work investigates and assesses the performance of operation and control strategies to achieve compliance with emission limits, maximize nitrification ...
-
[45]
Advanced Wastewater Modelling | GPS-X - HydromantisGPS-X is a wastewater modelling simulation software for designing new or upgrading existing municipal and industrial wastewater treatment plants.
-
[46]
[PDF] Lesson C2 Operation Costs of wastewater Treatment PlantsIn average for wastewater treatment plants in Europe with more than 10,000 p.e., the specific operation costs will amount up to 25– 35 €/p.e. and year.
-
[47]
Wastewater Treatment &Water Reclamation - PMC - PubMed CentralWastewater treatment is the means by which water that has been used and/or contaminated by humans or nature is restored to a desirable quality.