Fact-checked by Grok 2 weeks ago

Chemical oxygen demand

Chemical oxygen demand (COD) is a fundamental measure in that quantifies the amount of oxygen equivalent required to chemically oxidize the organic and inorganic matter present in a sample using a strong oxidant, such as , under controlled acidic and heated conditions. This parameter, expressed in milligrams of oxygen per liter (mg/L), provides an indication of the total pollution load from oxidizable substances in ground, surface, domestic, and industrial waters. COD testing is essential for assessing because it offers a quick and reliable estimate of levels, typically completed in 2-3 hours, compared to the slower (BOD) test, which relies on microbial degradation and can take up to five days. While BOD specifically measures the oxygen consumed by biodegradable , COD captures a broader spectrum, including both biodegradable and non-biodegradable compounds as well as some inorganics, often resulting in higher values (typically 1.5-2.5 times BOD for many wastewaters) that better reflect total oxidizable content. This makes COD particularly valuable for monitoring efficiency, evaluating industrial effluents, and ensuring compliance with environmental regulations, as it helps predict the potential impact on dissolved oxygen in receiving s. Elevated COD levels indicate high loads that can lead to oxygen depletion and significant risks to ecosystems, underscoring its role in and sustainable management.

Introduction

Definition and Principles

Chemical oxygen demand (COD) is defined as the amount of oxygen equivalent, expressed in milligrams per liter (mg/L), required to chemically oxidize the organic and oxidizable inorganic matter in a sample using a strong under controlled conditions. This provides an estimate of the total oxidizable content, serving as a key indicator of pollution potential in and natural waters. The underlying principle of COD measurement relies on the complete chemical oxidation of reduced substances to their fully oxidized states, such as (CO₂), (H₂O), and other stable products, using a stoichiometric equivalent of oxygen. This contrasts with methods by aiming for near-total conversion of oxidizable material, assuming that the oxygen demand corresponds directly to the theoretical amount needed for the . The general stoichiometric basis can be represented as: \text{organic matter} + \ce{O2} \rightarrow \ce{CO2 + H2O} where the oxygen consumption reflects the degree of reduction in the sample's compounds. COD encompasses a broad range of substances, including both biodegradable and non-biodegradable organic compounds, as well as certain inorganic species in reduced forms, such as sulfides, ferrous iron (Fe(II)), and manganous manganese, which are quantitatively oxidized during the process. Unlike biological oxygen demand (BOD), which focuses solely on microbial degradation of organics, COD captures the total chemically oxidizable load regardless of biodegradability.

Importance in Environmental Analysis

Chemical oxygen demand (COD) serves as a critical indicator for estimating the load in , industrial effluents, and surface waters by quantifying the oxygen required to chemically oxidize and some inorganic matter. This parameter enables rapid assessment of levels, facilitating the monitoring of efficiency and with environmental permits, a practice established since the 1970s. One key advantage of COD over biochemical oxygen demand (BOD) is its speed, producing results in 1.5 to 3 hours compared to the 5 days needed for BOD, which supports real-time operational adjustments in treatment processes. Additionally, COD captures the total oxidizable content, including recalcitrant and non-biodegradable compounds that resist microbial breakdown, making it suitable for analyzing toxic or inhibitory wastewaters where BOD testing is impractical. In comparison to BOD, COD typically overestimates the oxygen demand because it includes non-biodegradable organics, with COD:BOD ratios generally ranging from 1.5 to 2.5; ratios below 2 indicate readily biodegradable , while higher values suggest poorer biodegradability and the presence of persistent pollutants. For instance, effluents often exhibit a COD:BOD ratio around 2:1, whereas wastewaters may reach 5:1, guiding treatment strategy selection. COD plays an essential role in effluent standards, river quality indexing, and process control within industries such as food processing and textiles, where it helps evaluate pollutant loads and treatment performance. Elevated COD concentrations in discharged waters pose a significant environmental risk by promoting oxygen depletion, which can lead to hypoxic conditions and adverse effects on aquatic life, including reduced biodiversity and ecosystem disruption.

Measurement Methods

Potassium Dichromate Oxidation

The oxidation method employs K₂Cr₂O₇ as the primary oxidant in a strongly acidic medium, typically (H₂SO₄), where Cr(VI) is reduced to Cr(III), facilitating a 6-electron transfer per of dichromate. This selection of dichromate is preferred due to its potent oxidizing capability in acidic conditions and its , which ensures reliable quantification of oxidizable matter in samples. The core involves the : \text{Cr}_2\text{O}_7^{2-} + 14\text{H}^+ + 6\text{e}^- \rightarrow 2\text{Cr}^{3+} + 7\text{H}_2\text{O} This process oxidizes over 95% of typical organic compounds under conditions, converting them to , , and other oxidized products, while the excess dichromate remains for subsequent measurement. Key reagents include a standard 0.0417 M (0.25 N) K₂Cr₂O₇ solution, prepared by dissolving 12.259 g of dried K₂Cr₂O₇ (at 150°C for 2 hours) in 1 L of , which serves as the . (Ag₂SO₄) is added as a catalyst at approximately 5.5 g per kg of H₂SO₄ to enhance the oxidation of organic chlorides, while mercuric sulfate (HgSO₄) is used to complex ions (at a 10:1 Hg:Cl ratio, e.g., 10 g HgSO₄ per 100 mL sample for high-chloride waters), preventing with the dichromate reaction. For sample handling, high-COD samples exceeding 1000 mg/L are diluted with to ensure complete oxidation within the reagent capacity, and the mixture is heated either by refluxing at (approximately 100°C) in open systems or at 150°C for 2 hours in closed systems to promote thorough digestion. The endpoint is detected using ferroin indicator, a complex of and Fe²⁺ (prepared as 1.485 g monohydrate and 0.695 g FeSO₄·7H₂O in 100 mL ), which produces a distinct color change from blue-green (indicating excess dichromate) to reddish-orange upon reduction.

Reflux and Titration Procedures

The open method for chemical oxygen demand (COD) analysis involves using 250- to 500-mL Erlenmeyer flasks or round-bottom flasks connected to condensers to prevent loss of volatile compounds during . A typical begins by pipetting 50 mL of sample into the flask, followed by the addition of mercuric sulfate to complex chlorides, concentrated , and potassium solution, with gentle mixing to avoid excessive generation. beads are added to minimize and bumping, after which the flask is attached to a condenser and heated on a or to a gentle , maintaining for exactly 2 hours. Upon completion, the mixture is cooled to , the condenser is rinsed with about 25 mL of , and the contents are diluted to approximately 350 mL to prepare for . In contrast, the closed reflux method employs sealed vials or ampoules, typically 10- to 25- capacity, which allow for smaller sample volumes (2.5 to 10 ) and reduce the risk of volatile loss compared to open systems. The sample is combined with digestion solution and in the , which is then sealed with a screw cap or heat-sealed, mixed by inversion, and placed in a preheated aluminum block digester maintained at 150 ± 2°C for 2 hours. This method, as outlined in Standard Methods 5220C, is particularly advantageous for handling samples with high or when minimizing use and space is desired. After , the vials are cooled to in a controlled manner to avoid buildup. The titration process for both open and closed reflux methods is a back-titration to quantify the excess dichromate remaining after oxidation. For open reflux, the cooled and diluted mixture is transferred to an , and 10 drops of ferroin indicator are added, turning the solution blue-green; it is then titrated with 0.25 N ferrous ammonium sulfate () until the color change to reddish-brown. In closed reflux, the contents are similarly treated with a diluted ferroin indicator (1:5 with ) and titrated using a microburette with 0.10 N to the same . A blank determination using is performed concurrently to account for any reagent consumption, with all titrations conducted in triplicate for accuracy. Safety considerations are paramount due to the corrosive and toxic nature of the reagents involved. Concentrated sulfuric acid and hexavalent chromium in dichromate pose severe hazards, requiring the use of fume hoods for ventilation to handle acidic fumes and chromium vapors, along with personal protective equipment including gloves, face shields, and lab coats. In closed reflux, sealed vessels may develop internal pressure during heating, necessitating digestion behind a blast shield and careful cooling to prevent explosions; any spills should be neutralized immediately with sodium bicarbonate. Waste containing mercury and chromium must be disposed of according to environmental regulations to avoid contamination. Essential equipment includes reflux condensers (300-mm length for open method), heating mantles or hot plates capable of precise (at least 1.4 W/cm² surface power density), and Class A glassware for accuracy. Burettes or microburettes (10-mL capacity with 0.02-mL divisions) are used for , while for low COD samples (5-50 mg/L), a spectrophotometric alternative measures at 600 nm post-digestion in closed setups, offering higher sensitivity without .

Calculations and Data Interpretation

COD Determination Formulas

The determination of chemical oxygen demand (COD) primarily relies on the oxidation method, where the amount of oxidant consumed by the sample is quantified through with ammonium sulfate (FAS). The basic formula for COD in the open reflux titrimetric procedure is given by: \text{COD (mg O}_2\text{/L)} = \frac{(A - B) \times N \times 8000}{V} Here, A is the volume of FAS (in mL) used to titrate the blank, B is the volume of FAS (in mL) used to titrate the sample, N is the of the FAS , and V is the volume of the sample (in mL). The factor 8000 arises from the stoichiometric of oxygen (8 g O₂ per equivalent of dichromate) multiplied by 1000 to convert to mg/L units. In the closed reflux, colorimetric method, COD can also be determined spectrophotometrically by measuring the absorbance of the remaining Cr³⁺ at 600 after . The concentration is calculated using a prepared from standards: \text{COD (mg/L)} = \frac{(\text{Abs}_\text{sample} - \text{Abs}_\text{blank})}{\text{slope}} \times \text{dilution factor} The slope is derived from the of absorbance versus known COD concentrations (typically 10–500 mg/L), and the dilution factor accounts for any sample dilution to bring readings within the instrument range. Blank correction is essential to subtract the oxygen demand from reagents and any contamination, achieved by processing a reagent blank alongside samples and subtracting its titer or absorbance value from the sample results. To ensure complete oxidation, sufficient excess dichromate must be provided such that some remains unreacted after digestion; if too little remains, the sample should be diluted and reanalyzed to avoid incomplete oxidation of recalcitrant organics. The formula inherently involves units conversion from milliequivalents per liter (meq/L) of dichromate consumed to mg O₂/L, using the factor 8 (the equivalent weight of O₂ based on the six-electron transfer in Cr⁶⁺ to Cr³⁺ reduction) multiplied by 1000 for dimensional consistency. COD values are reported over a wide range, from 5 mg/L (using micro methods or high dilutions) to 50,000 mg/L (for undiluted industrial wastes), depending on sample dilution and method sensitivity. Error analysis indicates a of approximately ±5–10% (CV) for COD levels between 50 and 1000 mg/L, based on single-laboratory studies with standard samples. Duplicate or triplicate analyses are required for each batch to verify agreement within 5% of the mean, ensuring reliable results for .

Excess Oxidant Measurement

In chemical oxygen demand (COD) analysis, measuring the excess oxidant quantifies the unreacted (K₂Cr₂O₇, as Cr(VI)) after the oxidation step, allowing subtraction from the initial amount to determine the oxidant consumed by the sample and thus the COD value. This measurement ensures the reaction conditions provided sufficient oxidant for complete oxidation of ; if too little remains unreacted, it suggests incomplete oxidation or excessively high sample COD, necessitating re-analysis with adjusted sample volume or oxidant dose. The standard titrimetric method involves back-titration of the digested sample with ferrous ammonium sulfate (, Fe(NH₄)₂(SO₄)₂) solution after dilution and cooling. A blank (reagent ) is titrated similarly to establish the initial equivalent. The endpoint is determined visually with ferroin indicator, marked by a sharp color change from blue-green to reddish-brown, or potentiometrically for greater precision in turbid samples. The excess dichromate percentage is calculated as (V_s / V_b) \times 100, where V_s is the FAS volume (mL) for the sample and V_b for the blank, confirming the residual fraction relative to the initial amount. An alternative spectrophotometric approach directly assesses residual Cr(VI) by measuring absorbance at 440 nm post-digestion, leveraging the Beer-Lambert law: A = \epsilon \cdot l \cdot c where A is absorbance, \epsilon is the molar absorptivity of dichromate (approximately 4.8 × 10³ L/mol·cm at 440 nm), l is the path length (typically 1–5 cm), and c is the Cr(VI) concentration. A digested blank serves as reference, and the difference in absorbance correlates to COD via calibration; this method suits high-throughput labs but requires verification against titrimetry for accuracy. Quality control mandates daily standardization of FAS titrant and analysis of blanks to subtract baseline oxidant demand, with duplicates agreeing within 5%. Initial dichromate doses typically range from 0.0167 N (low COD samples) to 0.25 N (high COD), added as 10–25 mL to 20–50 mL samples. If excess falls too low, troubleshoot by checking for high sample COD exceeding oxidant capacity, inadequate reflux time, or catalyst issues (e.g., insufficient Ag₂SO₄), and re-run accordingly to validate results.

Interferences and Limitations

Inorganic and Chloride Effects

In the chemical oxygen demand (COD) test using oxidation, various inorganic species can act as reducing agents, consuming the oxidant and thereby inflating the measured COD values beyond the organic content alone. Reduced inorganic compounds, such as ferrous iron (Fe²⁺), manganous manganese (Mn²⁺), (S²⁻), and (NO₂⁻), undergo quantitative oxidation under the acidic conditions of the method. For instance, exerts an oxygen demand of 1.1 mg O₂ per mg NO₂⁻-N, though its impact is typically minor in samples with concentrations below 1–2 mg NO₂⁻-N/L. Similarly, ferrous iron is oxidized to ferric iron (Fe³⁺) via the redox reaction with (Cr(VI)), reducing it to trivalent (Cr(III)):
\ce{3Fe^{2+} + Cr^{6+} -> 3Fe^{3+} + Cr^{3+}}
This process directly contributes to the apparent COD, with the extent depending on the concentration of the inorganic reductant.
Chloride ions (Cl⁻) represent one of the most significant inorganic interferences in the dichromate-based COD assay, particularly in saline or brackish water samples. In the presence of a silver sulfate catalyst, chloride is oxidized to elemental chlorine (Cl₂) by the dichromate oxidant under acidic conditions:
\ce{Cr2O7^{2-} + 6Cl^- + 14H^+ -> 2Cr^{3+} + 3Cl2 + 7H2O}
This reaction consumes dichromate stoichiometrically, leading to a positive bias in COD results that can reach 20–50% overestimation in samples with high salinity, such as seawater or industrial effluents. The theoretical oxygen equivalent for this interference is 0.226 mg O₂ per mg Cl⁻, based on the redox stoichiometry where two moles of Cl⁻ require one-half mole of O₂ for oxidation to Cl₂. Interference becomes pronounced when chloride exceeds 1000 mg/L, rendering COD values below 250 mg/L unreliable without accounting for this effect.
Other halides, such as (Br⁻) and (I⁻), exhibit similar but more pronounced interference due to their lower oxidation potentials compared to . These ions are readily oxidized to Br₂ and I₂, respectively, by Cr(VI), resulting in even greater positive biases in COD measurements for samples containing elevated levels of these , such as in coastal or disinfected waters. The impact of these inorganic interferences is often quantified through spiked sample experiments, where known concentrations of the interferent are added to blanks or standards to isolate their contribution to oxidant consumption.

Correction Techniques

To address chloride interference in COD measurements, mercury(II) sulfate (HgSO₄) is added to the sample prior to digestion at a ratio of 10 mg HgSO₄ per 1 mg of , forming the undissociated HgCl₂ that prevents chloride oxidation by dichromate. This masking technique is effective for chloride concentrations up to approximately 2000 mg/L, beyond which excessive HgSO₄ can lead to incomplete organic oxidation or analytical inaccuracies, necessitating alternative approaches like dilution or chloride subtraction via standard curves. For higher chloride levels in saline samples, such as or industrial effluents, numeric corrections based on chloride standards or ionic exchange pre-treatments can further refine results, though HgSO₄ remains the primary masking agent in standard protocols. Inorganic interferences from species like nitrites and reduced metals (e.g., Fe²⁺, Mn²⁺) can be mitigated through targeted pre-treatments. Nitrite interference, which contributes to positive bias by direct oxidation, is eliminated by adding 10 mg of per mg of nitrite-nitrogen (as N) to the sample, decomposing nitrite to gas without affecting . For metals, using 0.45 μm membranes removes particulate-bound forms, while dissolved reduced metals may require pre-treatment with mild oxidants like to convert them to non-interfering oxidized states prior to COD analysis; alternatively, low-range dichromate reagents (e.g., 0.0167 N K₂Cr₂O₇) are employed for samples with minimal inorganic content to enhance precision and reduce bias. These steps ensure that only organic oxygen demand is quantified in low-interference matrices like freshwater. Method variations help minimize losses and adapt to sample matrices. The closed reflux procedure, using sealed vials or ampoules, prevents the escape of volatile organics during digestion at 150°C for 2 hours, improving recovery compared to open reflux methods and reducing exposure to hazardous fumes. For high-chloride waters, sample dilution (e.g., 1:10 or greater) lowers the effective chloride concentration below masking limits while maintaining measurable COD levels, with results adjusted proportionally. These adaptations are integral to protocols like Standard Methods 5220C, ensuring robust applicability across diverse environmental samples. In colored or turbid samples, visual endpoint detection during titration can introduce errors; potentiometric titration serves as an alternative, monitoring potential changes with a electrode versus a reference to detect the Cr⁶⁺ to Cr³⁺ reduction at approximately 1100 mV, providing higher accuracy without indicator reliance. This technique is particularly useful in industrial wastewaters where pigments obscure color changes. Validation of corrected COD measurements involves spike recovery tests and inter-laboratory comparisons to confirm reliability. Spiking samples with a known standard (e.g., ) should yield recoveries of 85–115%, indicating effective interference control; deviations outside this range signal residual issues requiring method adjustment. Inter-laboratory proficiency testing, as outlined in EPA Method 410.4, assesses reproducibility with relative standard deviations typically below 15% for levels above 50 mg/L, ensuring standardized application in regulatory monitoring.

Applications and Regulations

Wastewater and Water Quality Monitoring

Chemical oxygen demand (COD) plays a crucial role in by monitoring influent and effluent levels to optimize processes such as , where real-time data helps adjust and to achieve efficient removal. In systems, typical COD reductions exceed 90%, with studies reporting average removal efficiencies of 95.7% under optimized conditions, enabling operators to maintain treatment performance and comply with discharge requirements. In assessment, is integrated into Indices (WQIs) to evaluate overall levels and suitability for uses like sources. Thresholds for in such assessments are typically below 20 mg/L for potable water origins, helping to identify areas needing intervention to prevent oxygen depletion and harm. For industrial applications, COD measurements are essential in sectors like pulp and paper, where wastewater often exhibits concentrations ranging from 500 to 5000 mg/L due to lignins and other organics, guiding pretreatment strategies before discharge. In the , effluents present high COD loads, frequently exceeding 9000 mg/L from active ingredients and solvents, necessitating advanced oxidation or biological enhancements for effective management. Real-time COD sensors in these settings enable continuous monitoring to minimize environmental release. Case studies illustrate COD's utility in tracking improvements in rivers downstream of plants; for instance, in Korea's Gap , COD levels from effluents were monitored to assess dilution and fate, revealing reductions post-treatment but persistent hotspots. Additionally, elevated COD correlates with increased in such systems, as organic loads contribute to bioavailable pollutants that impair aquatic life, underscoring COD's role as a for broader ecological risks. Emerging applications include probes using for direct field COD analysis, allowing rapid detection without lab transport, as demonstrated in submersible multiparameter systems developed since 2020. Integration with (IoT) platforms further advances smart water management, enabling automated data collection and for proactive pollution control in dynamic environments.

Government Standards and Limits

In the United States, the Environmental Protection Agency (EPA) regulates chemical oxygen demand (COD) through the National Pollutant Discharge Elimination System (NPDES) under the Clean Water Act, where effluent limitations for COD are set in permits for industrial and municipal discharges to protect . For certain industries, such as chemical and allied products manufacturing, NPDES permits set technology-based effluent limitations for COD based on production-normalized loads or site-specific concentrations, often in the range of 50-200 mg/L depending on the subcategory and flow. The EPA approves specific analytical methods for COD measurement, including Method 410.1 for open reflux and Method 410.4 for closed reflux colorimetric procedures, which are used to verify adherence to these limits. In the , the Urban Wastewater Treatment Directive (91/271/EEC, as amended) establishes minimum treatment standards for urban wastewater, requiring to achieve at least 75% reduction in and an concentration not exceeding 125 mg/L O₂ for discharges from treatment plants serving over 2,000 population equivalents. The Urban Wastewater Treatment Directive was amended in 2024 (Directive (EU) 2024/3019), enhancing standards for wastewater reuse and treatment efficiency, while maintaining core reduction requirements. Complementing this, the (2000/60/EC) aims for good ecological status in surface waters, where member states may use as a supporting physico-chemical indicator, with thresholds like below 25 mg/L in some national systems for low organic pollution and support aquatic life. These directives are transposed into national laws, with member states enforcing stricter limits in designated sensitive areas to prevent . Internationally, the (WHO) provides guidelines for quality, using as a general indicator of contamination in source waters, emphasizing treatment to minimize levels for safety and palatability, without a fixed numerical limit. The (ISO) supports global harmonization through ISO 15705, which outlines a closed , sealed-tube method for determination in water and , applicable for regulatory compliance testing across borders. Regulatory limits vary by region and environmental sensitivity; for instance, imposes stricter effluent standards under the Water Pollution Control Law, with COD limits of 160 mg/L nationally, but as low as 60-120 mg/L in closed or sensitive water bodies to protect . Dischargers must report COD levels in permit applications and ongoing submissions, often quarterly or as specified, to track trends and ensure preventive measures. Compliance monitoring for COD typically requires frequent sampling at high-volume facilities, such as daily measurements for major industrial plants under NPDES to detect exceedances promptly, while smaller operations may monitor weekly or monthly based on risk assessments. Penalties for non-compliance, including exceeding COD limits, can include civil fines up to $68,445 per day per violation in the US under the Clean Water Act (as of 2025), and in the EU, administrative fines or criminal sanctions varying by member state, potentially reaching millions of euros for significant breaches under the Urban Wastewater Treatment Directive.

Historical Development

Origins in Water Analysis

The origins of chemical oxygen demand (COD) as a parameter emerged in the mid-19th century amid growing concerns over from industrialization and , which threatened through contaminated and waterways. Early efforts focused on using (KMnO₄) as an oxidant to estimate the oxygen required to break down , providing a proxy for levels in sewage-laden rivers. The first documented permanganate-based test was introduced by Forchamer in 1849, who mixed known concentrations of the oxidant with water samples to gauge decolorization as an indicator of organic content. In , where rapid urban growth exacerbated river —particularly in the Thames and basins—these tests gained traction for monitoring discharge and its impact on aquatic ecosystems. chemists refined the technique for practical application: Tidy proposed a standardized oxygen absorption method in 1873, while Frankland, serving as analyst for London's from 1865, adapted it in 1876 to detect albuminoid and organic impurities in potable , emphasizing its role in preventing epidemics. These developments shifted from subjective sensory evaluations, such as and , to more objective quantitative assessments of oxidation equivalents, influencing early regulations across the continent. By the late , researchers like Wyatt in 1893 further improved protocols, but its incomplete oxidation of complex organics—typically capturing only 50-70% of potential demand—highlighted the need for stronger agents. This led to the exploration of (K₂Cr₂O₇) in the early , with Adeney and Dawson reporting its first use in 1926 for determining in water under acidic conditions, followed by preliminary experiments in the and demonstrating its superior ability to oxidize compounds under acidic, heated conditions. Initially developed to better evaluate strength for and river quality, these methods were incorporated into emerging U.S. standards in the mid-20th century; early efforts by the Service, in collaboration with the , had outlined protocols for related oxygen demand tests (primarily biochemical), prioritizing their use in assessing pollution loads for , with COD methods adopted later.

Evolution and Standardization

In the mid-20th century, significant advancements in COD measurement focused on improving oxidation efficiency and addressing interferences. In 1949, W.A. and colleagues introduced a dichromate-based using open at 145–150°C for 2 hours, achieving approximately 90% oxidation of in , though interference required correction. This open approach became foundational due to its robustness for high-sample volumes. By 1951, 's team enhanced the with as a catalyst to better oxidize resistant compounds like carboxylic acids. In 1963, R.A. Dobbs and others incorporated mercuric sulfate to suppress interference directly, simplifying the process by eliminating separate measurements. The closed vial (or closed ) method emerged around this period as a safer alternative to open , minimizing exposure to volatile reagents and improving laboratory safety, particularly for routine analyses. Standardization efforts accelerated in the 1950s and 1970s, embedding COD into regulatory frameworks. The (APHA) first included COD in the 10th edition of Standard Methods for the Examination of Water and Wastewater (1955), introducing the dichromate-silver sulfate procedure for industrial wastewaters, which marked a shift toward more comprehensive pollutant assessment. The U.S. Environmental Protection Agency (EPA) adopted these methods in the 1970s under the Clean Water Act (1972), approving COD tests like Method 410.1 (open reflux, titrimetric) for monitoring to enforce discharge limits and support national goals. Internationally, ISO 6060 (first published 1986, revised 1989) formalized the dichromate reflux method for waters with COD values of 5–1,000 mg/L, emphasizing precision and reproducibility; it remains a reference standard despite later withdrawal in favor of national adaptations. Recent developments since the have emphasized portability, reduced , and . Spectrophotometric COD kits, introduced in the early , enabled colorimetric detection of dichromate reduction at 420 nm after closed , facilitating field and low-volume testing with pre-packaged . In the , and biosensors advanced alternatives for on-site monitoring; for instance, biosensors using microbial oxidation measured heat release from , offering rapid (under 30 minutes) and portable results with detection limits around 10 mg/L COD. variants post-2000 have sought to eliminate (Cr(VI)) due to its , including photoelectrochemical methods like PeCOD® (using TiO2 for Cr-free oxidation) and persulfate-based , which achieve comparable accuracy while minimizing . Global harmonization gained traction in the 1990s through organizations like the (UNEP), whose 1995 Global Programme of Action for the Protection of the Marine Environment from Land-Based Activities incorporated COD into criteria for pollution control, promoting consistent monitoring across regions. Adaptations addressed site-specific challenges, such as in tropical climates where high humic content from vegetation can overestimate COD by up to 50% in standard dichromate assays; corrections via alternative oxidants or UV absorbance adjustments have been recommended to improve accuracy in such environments.

References

  1. [1]
    Oxygen demand, chemical - Substance Details - SRS | US EPA
    Definition: A measure of the oxygen equivalent of the organic matter content of a sample that is susceptible to oxidation by a strong chemical oxidant, usually ...
  2. [2]
    [PDF] Method 410.4, Revision 2.0: The Determination of Chemical Oxygen ...
    1.1 This method covers the determination of chemical oxygen demand (COD) in ground and surface waters, domestic and industrial wastes. 1.2 The applicable range ...
  3. [3]
    [PDF] Biochemical Oxygen Demand (BOD) and Carbonaceous BOD ...
    The purpose of the biochemical oxygen demand (BOD5) test is to measure the potential of wastewater and other waters to deplete the oxygen level of receiving ...
  4. [4]
    Method development for measuring biodegradable organic carbon ...
    Jul 1, 1998 · Analyses that measure oxygen demand, such as biochemical oxygen demand (BOD) and chemical oxygen demand (COD) analyses, have long ... advantages ...
  5. [5]
    [PDF] The Science of CHEMICAL OXYGEN DEMAND
    Background on Oxygen Demand Testing. Oxygen demand Is an important parameter for deter- mining the'amount of organic pollution in water. The.
  6. [6]
    Water Quality Testing Parameters | Missouri Department of Natural ...
    The chemical oxygen demand, or COD, is used as a measure of the oxygen equivalent of the organic matter content of a sample that is susceptible to oxidation ...
  7. [7]
    [PDF] 5220 chemical oxygen demand (cod) - Edge Analytical Laboratories
    Chemical oxygen demand (COD) is defined as the amount of a specified ... Approved by Standard Methods Committee, 1997. Joint Task Group: 20th Edition ...
  8. [8]
    Understanding Laboratory Wastewater Tests: I. Organics (BOD ...
    COD (chemical oxygen demand). COD is the most popular alternative test to BOD for establishing the concentration of organic matter in wastewater samples. The ...
  9. [9]
    [PDF] Method 410.3: Chemical Oxygen Demand (Titrimetric, High Level for ...
    Method 410.3: Chemical Oxygen Demand (Titrimetric, High Level for Saline Waters) by Titration. Page 1. Office of Water. www.epa.gov. 1978.
  10. [10]
    COD, BOD, and, TOC in water—An overview through time
    Mar 27, 2023 · ... oxidized in the presence of potassium dichromate and sulfuric acid, in 2-h reflux at a temperature of 150 °C (open or closed). HgSO4 are ...
  11. [11]
    None
    ### Closed Reflux Method Procedure for COD (Chemical Oxygen Demand)
  12. [12]
    [PDF] Oxygen demand, chemical (COD), colorimetric, dichromate oxidation
    The COD concentration is determined spectrometrically by measuring the absorbance of the Cr+3 that is formed. 2.2 Additional information about the principles ...
  13. [13]
    [PDF] Oxygen demand, chemical (COD), titrimetric, dichromate oxidation
    Reducing substances such as ferrous iron, nitrites, and chlorides interfere, because they are oxidized. Chlorides constitute by far the greatest and most ...
  14. [14]
    An improved determination of chemical oxygen demand in water ...
    A simplified and improved chemical oxygen demand (COD) procedure is suitable for water and waste water samples containing up to 1500 mg Cl l −1.Missing: minimum | Show results with:minimum
  15. [15]
    [PDF] The Science of - CHEMICAL OXYGEN DEMAND
    One molecule of oxygen consumes 4 molecules of chloride ions. On a weight basis, the theoretical oxygen demand for chloride is 0.226 mg O2 per mg Cl–. A sample.
  16. [16]
    Reduction of chloride ion interference in chemical oxygen demand ...
    Furthermore, higher COD levels can tolerate higher chloride ion concentrations, whereas lower COD levels tolerate lower chloride ion concentrations [8]. To this ...
  17. [17]
    [PDF] COD determination: Removing Cl- Interference in S t Seawaters
    Jul 3, 2013 · A) Interference elimination Chloride​​ Cl- in dichromate gets oxidized to chlorine gas producing erroneously high COD levels (2) [1] . Ag+ + Cl- ...
  18. [18]
    5220 CHEMICAL OXYGEN DEMAND (COD) - Standard Methods
    Chemical oxygen demand (COD) is defined as the amount of a specified oxidant that reacts with the sample under controlled conditions.
  19. [19]
    [PDF] Potentiometric-measurement-of-chemical-oxygen-demand.pdf
    The objectives of this investigation were firstly, to compare the potentiometric end-point method (a titration procedure) with recommended standard methods of.
  20. [20]
    A rapid potentiometric titration method for measuring low-level ...
    In this work, we have developed a rapid determination method for the low-level chemical oxygen demand (COD) index in dye-containing wastewater samples.
  21. [21]
  22. [22]
  23. [23]
    Evaluating the Efficiency of Activated Sludge Processes in Treating ...
    Jun 25, 2024 · Initially, in February and March 2019, the treatment process achieved an average COD removal efficiency of 95.7%, with a COD load of 0.56 kg COD ...
  24. [24]
    A comprehensive review of water quality indices (WQIs)
    Mar 11, 2023 · Water quality index (WQI) is one of the most used tools to describe water quality. It is based on physical, chemical, and biological factors that are combined ...
  25. [25]
    What are the standard limits ( acceptable value) for BOD and COD in ...
    Jul 9, 2022 · BOD ranges from 5mg/L to 10mg/L. COD surface water resources typically range less than or equal to 20 mg/L and 200mg/L for water receiving effluents.
  26. [26]
    Pulp and Paper Industry Wastewater Treatment - Boromond
    COD at 300 to 2500 mg/L: The chemical oxygen demand is high due to the presence of organic materials like lignin. COD depends on the specific pulping methods ...
  27. [27]
    Integrated system for recycling and treatment of hazardous ...
    Jun 20, 2022 · On the other hand, pharmaceutical wastewater is typically toxic for both aquatic life and biological life, with high COD and low ...
  28. [28]
    Prediction of BOD, COD, and Total Nitrogen Concentrations in a ...
    Jan 16, 2012 · The Gap River in Korea is a typical urban river, which is affected by the effluent of a wastewater treatment plant (WWTP) and various ...
  29. [29]
    Effectiveness of Chemical Oxygen Demand as an Indicator of ...
    COD is most commonly determined by using potassium dichromate (K2Cr2O7) or potassium permanganate (KMnO4) as an oxidizing agent to oxidize organic matter in a ...
  30. [30]
    In Situ Water Quality Monitoring Using an Optical Multiparameter ...
    We developed a submersible sensor probe, which combines UV/Vis and fluorescence spectroscopy together with a flexible data processing platform.
  31. [31]
    Advances in machine learning and IoT for water quality monitoring
    The integration of IoT devices with ML algorithms holds great promise for enhancing WQM by facilitating real-time data collection and analysis. This combination ...
  32. [32]
  33. [33]
    6— Edward Frankland: The Analyst As Activist
    The chemist Edward Frankland, who from 1866 until his death in 1899 served as the quasi-official 'government analyst' of the London water supply.
  34. [34]
    Naturalizing pollution: a critical social science view on the link ...
    Dec 3, 2018 · In the nineteenth century, organic matter was considered the worst form of pollution for its immediate effects on human health through water- ...
  35. [35]
    Chemical oxygen demand: Historical perspectives and future ...
    ISO 6060 states that the accepted definition of COD (chemical oxygen demand) is the mass concentration of oxygen that is equivalent to the amount of dichromate ...
  36. [36]
    ISO 6060:1989 - Determination of the chemical oxygen demand
    Method specified is applicable to water with a value between 30 mg/l and 700 mg/l. The chloride contents must not exceed 1 000 mg/l.Missing: reflux | Show results with:reflux
  37. [37]
    Development of chemical oxygen demand (COD) detection
    Jun 7, 2024 · The origin of COD detection can be traced back to the 1850s, when water pollution problems had attracted people's attention. Initially, COD was ...
  38. [38]
    A Novel Thermal Sensor for the Sensitive Measurement of Chemical ...
    A novel rapid methodology for determining the chemical oxygen demand (COD) based on a thermal sensor with a flow injection analysis system was proposed and ...
  39. [39]
    Sustainable and green persulfate-based chemiluminescent method ...
    Aug 29, 2022 · The method using activated persulfate is suitable for use as COD quantitation/screening tool in surface waters.Missing: post | Show results with:post
  40. [40]
    Correcting a major error in assessing organic carbon pollution in ...
    Apr 14, 2021 · However, the COD method requires the addition of high amounts of strong chemical oxidants (i.e., potassium dichromate and permanganate), which ...