Shading coefficient

The shading coefficient () is a dimensionless ratio that quantifies the amount of through a product, such as a or glazing system, relative to the through a standard reference of 1/8-inch (3 mm) thick clear float glass, which has an SC of 1.0. Lower SC values, typically ranging from 0 to 1, indicate reduced transmission and absorption that is reradiated inward, making it a key metric for evaluating thermal performance in building envelopes. Historically, the was a primary standard in building energy codes and design practices, particularly under guidelines, to assess how glazing types—like tinted, reflective, or low-emissivity coated —mitigate unwanted gains in warm climates. It accounts for both directly transmitted radiation and a portion of absorbed re-emitted into the interior , influencing cooling loads, occupant comfort, and overall . For instance, combining SC with exterior shading devices, such as overhangs or fins, can further lower effective solar heat gain, optimizing while minimizing and overheating. In modern applications, the SC has largely been supplanted by the more precise solar heat gain coefficient (SHGC), which measures total transmittance on a scale from 0 to 1 and includes all inward flows without relying on a historical reference . The two metrics are interrelated, with SC approximately equal to SHGC multiplied by 1.15 (or conversely, SHGC ≈ SC × 0.87), allowing for conversions in legacy compliance assessments. Despite this shift, SC remains relevant in certain international standards and simulations for older buildings or evaluating shading systems like blinds and curtains, where values as low as 0.3 can significantly cut air-conditioning demands.

Definition and Fundamentals

Definition

The shading coefficient (SC) is a dimensionless ratio that measures the total solar heat gain through a glazing system relative to that of a reference standard, defined as 1/8-inch (3 mm) thick clear, double-strength single glass, which has an SC of 1.0 by definition. This metric evaluates the glazing's performance in transmitting solar energy, where an SC less than 1.0 indicates reduced heat gain compared to the clear glass baseline. Solar heat gain refers to the total radiant heat entering a building through the glazing, comprising the transmitted portions of direct from , scattered by the atmosphere, and ground-reflected from surrounding surfaces. These components collectively determine the thermal load on the interior space, with the SC quantifying how effectively the glazing system attenuates this gain while still permitting visible light transmission. Typical SC values range from 0, representing no heat gain (ideal for complete ), to 1.0, equivalent to the reference clear . Modern low-emissivity (low-e) coated often achieves SC values between 0.2 and 0.5, providing substantial reduction in ingress. In , the SC serves to assess a window's capacity to mitigate unwanted , particularly in hot climates, thereby aiding in occupant comfort and without fully blocking daylight.

Historical Development

The American Society of Heating, Refrigerating and Air-Conditioning Engineers () began investigating solar radiation effects on buildings during the 1950s and early 1960s, focusing on how glazing contributed to cooling loads in air-conditioned spaces. The calculation method for the shading coefficient was proposed by D.G. Stephenson in a 1967 technical note published by the National Research Council of Canada. This led to the formal introduction of the shading coefficient in the 1970s as a simplified metric for estimating solar heat gain through windows. By 1972, the concept was incorporated into the Handbook of Fundamentals, marking its integration into standard engineering practice for fenestration analysis. Initially, the shading coefficient emphasized basic glass types, such as clear single-pane and early heat-absorbing varieties like gray or bronze tinted glass, which were prevalent in the and for reducing transmittance without advanced treatments. The , triggered by the 1973 oil embargo, accelerated its evolution by highlighting the need for passive control strategies amid soaring energy costs and demands. This period saw expanded application of the metric to tinted and emerging coated glasses, including the development of low-emissivity (low-e) coatings funded by U.S. to enhance in windows. ASHRAE's response included the release of Standard 90 in 1975, which for the first time prescribed shading coefficient limits for in energy-efficient building designs, influencing national standards during subsequent oil shortages. In the and , advancements in computational modeling and more accurate performance metrics prompted a shift toward precise evaluations of glazing systems, with the heat gain coefficient (SHGC) gaining prominence in updated standards like 90.1-1989. Despite this transition, the shading coefficient persisted as a practical, straightforward tool for engineers and architects, particularly in preliminary design phases and legacy applications, due to its simplicity in comparing relative heat gains across glazing options.

Calculation and Measurement

Formula and Components

The shading coefficient (SC) is calculated as the ratio of the total solar heat gain through a specific glazing system to the total solar heat gain through a reference glazing of 1/8-inch (3 mm) clear under normal incidence (90° to the surface). This can be expressed mathematically as: \text{SC} = \frac{\text{Total solar heat gain through specific glazing}}{\text{Total solar heat gain through reference 1/8-inch clear glass}} The total heat gain for a glazing system comprises two primary components: the directly transmitted portion of the incident (including both and diffuse components) and the fraction of absorbed that is subsequently re-radiated or conducted inward toward the building interior. Reflected , while part of the overall at the glazing surface, does not contribute to the inward heat gain and is thus excluded from the numerator. The reference glazing—a standard 1/8-inch clear —has a total gain of approximately 0.87 under the standard spectrum at normal incidence, establishing a where = 1.0 for this material. Several factors influence the value of a glazing system. thickness affects and slightly, with thicker panes generally increasing and thus potentially altering the inward flow, though the effect is modest compared to other modifications. Tinting reduces by absorbing more near-infrared and visible , lowering both direct and overall gain; for example, tinted double glazing can achieve an around 0.52 versus 0.75 for untinted equivalents. Reflective coatings, such as low-emissivity (low-e) layers, significantly decrease by reflecting outward. Multiple glazing layers, as in insulated units (IGUs), further reduce through increased and reduced across layers. Although can vary with the angle of incidence due to changes in and , it is conventionally reported at normal incidence (0° angle) for . Conceptually, SC relates to the heat gain coefficient (SHGC) via the approximation SC ≈ SHGC / 0.87, providing a bridge between the two metrics but not intended for precise interconversion due to differences in scope and reference conditions.

Testing Methods

The (SC) of systems is empirically determined through a combination of direct measurements and computational simulations, ensuring accurate assessment under standardized conditions that replicate . methods primarily involve calorimetric techniques to quantify through glazing and shading elements. One established approach uses a hot-box apparatus, where the sample is mounted between a warm indoor chamber and a cool outdoor chamber, with controlled introduced via lamps or natural exposure to measure total solar heat gain. This method, detailed in NFRC 201, maintains an irradiance of approximately 1000 W/m² across the standard (ASTM E891 or equivalent) to calculate SC from the ratio of measured heat gain to that of reference clear glass. Similarly, simulators provide a controlled artificial light source mimicking the full , as specified in ISO 19467, where the sample is exposed in a climatic chamber with metering boxes to isolate center-of-glazing performance, often achieving precision within ±0.02 for SC values. These setups account for steady-state conditions, with temperatures held at 21°C indoors and -18°C outdoors, and wind speeds of 5.5 m/s to simulate real-world boundary layers. Simulation tools offer a complementary method for determining SC when direct testing is impractical for complex assemblies, relying on measured (transmittance, , and ) of individual layers. Software such as and , developed by , models SC by integrating spectral data from the International Glazing Database with finite-element analysis, following ISO 15099 for multi-layer calculations. Users input layer-specific data—gathered via under NFRC-approved protocols—and the tools compute SC at the center-of-glazing, edge, and whole-product levels using area-weighted averages. For instance, Venetian blinds or woven shades are parameterized by slat geometry and , enabling dynamic simulations that align with NFRC 200 procedures for . Incidence angle effects are critical for realistic SC evaluation, as solar radiation at oblique angles alters optical performance due to increased path length and reflection. Standard laboratory tests focus on normal incidence (0°) for baseline SC, but simulations in WINDOW adjust for angles up to 80° by applying angular-dependent transmittance factors from spectral measurements, with corrections for building orientations via projection factors. NFRC guidelines require reporting SC at normal incidence for labels, while off-normal values (e.g., 10°–60°) are derived computationally to inform design, showing typical reductions in effective SC by 10–20% at 45° for low-e glazings. Certification processes validate SC claims through third-party oversight by organizations like the National Fenestration Rating Council (NFRC), which accredits laboratories and approves simulation inputs to prevent manufacturer overstatements. Samples undergo independent testing or simulation verification, with results certified under NFRC 200 and 201 if deviations exceed 0.05 from declared values, ensuring compliance for energy labeling programs. This rigorous process, involving audited data from IGDB, supports widespread adoption in building simulations.

Relation to Other Performance Metrics

Comparison with Solar Heat Gain Coefficient

The Solar Heat Gain Coefficient (SHGC) is defined as the fraction of incident solar radiation admitted through a system, encompassing both the directly transmitted portion and the heat released inward from absorbed radiation. This metric ranges from 0 to 1, with values closer to 0 indicating greater resistance to solar heat gain and thus enhanced shading performance. Unlike the shading coefficient (SC), which expresses solar heat gain as a ratio relative to a standard single pane of clear glass (assigned SC = 1), SHGC provides an absolute measure independent of such a reference. The primary distinction lies in this relativity: SC normalizes performance against baseline glass, facilitating straightforward comparative assessments, whereas SHGC quantifies the total solar energy transmittance for the entire fenestration assembly, including frame effects. An approximate conversion between the two is given by SHGC ≈ SC × 0.87 under standard conditions, reflecting the SHGC of 3 mm clear float glass as the reference value of 0.87. The shift from SC to SHGC gained momentum in the early 1990s, driven by the need for more precise evaluations of complex fenestration systems that account for angular dependencies and spectral variations—limitations inherent in the older SC method. ASHRAE Technical Committee 4.5 initiated revisions in the late 1980s, culminating in a 1991 journal recommendation to adopt angle-dependent SHGC for energy simulations. Concurrently, the National Fenestration Rating Council (NFRC), formed in 1989 and federally recognized in 1992, incorporated SHGC into its rating procedures by the early 1990s to standardize energy performance labels. Despite this transition, SC persists in legacy U.S. building codes as an acceptable alternative (e.g., SC × 0.86 for SHGC compliance) and in international contexts, such as European standard EN 410, where it relates directly to the total solar energy transmittance factor (g-value). In practice, suits rapid evaluations of glazing options against a clear glass benchmark, particularly in preliminary stages or when referencing historical data. SHGC, however, is the standard for detailed applications, including whole-building energy modeling in tools like EnergyPlus, which relies on SHGC to simulate seasonal solar impacts accurately.

Distinction from Thermal Transmittance

The thermal transmittance, or U-value, measures the rate of steady-state heat flow through a fenestration product due to conduction, convection, and longwave infrared radiation, resulting from temperature differences across the assembly; it is independent of incident solar radiation and expressed in units of W/m²·K. Lower U-values indicate better insulating performance against non-solar heat transfer. The shading coefficient (SC), by contrast, quantifies the impact of shortwave radiation on heat gain through glazing, defined as the ratio of total solar heat gain at normal incidence relative to that through a standard 1/8-inch (3 mm) thick clear glass pane, which has an SC of 1.0; it is a unitless value ranging from 0 to 1, with lower values signifying greater shading effectiveness against solar-induced heating. This core distinction highlights that SC focuses exclusively on radiation and effects leading to heat gain, whereas the U-value addresses conductive and convective heat loss or gain from gradients, including components but excluding solar inputs. In building energy analysis, both metrics are integrated for holistic evaluation: the U-value informs heating-related calculations, such as degree-day methods for winter heat retention, while is applied to cooling scenarios to mitigate heat gain and reduce demands. The R-value, calculated as the inverse of the U-value (R = 1/U) in units of m²·K/W, offers an analogous measure of thermal resistance for purposes but cannot be directly compared to due to the latter's solar-specific orientation.

Applications in Building Design

Role in Energy Efficiency

The shading coefficient (SC) plays a pivotal role in enhancing building by minimizing heat gain through , thereby reducing the demand on (HVAC) systems. In sunny climates, glazing with a low SC—typically below 0.5—can decrease peak cooling loads, as demonstrated in parametric studies of residential prototypes in arid regions like , where combined low-SC glazing and passive reduced daily cooling energy by 30% compared to standard clear systems. This reduction translates to lower electricity consumption for cooling, which often accounts for over 30% of total building energy use in such environments, and decreases operational costs by optimizing HVAC sizing and runtime. For instance, in office buildings with significant glazing areas, lowering the SC from 1.0 (clear ) to 0.2 can cut annual cooling energy by up to 50% in hot, humid conditions, directly alleviating strain on mechanical systems. Beyond direct load reduction, low-SC glazing supports passive design strategies that promote natural ventilation and while mitigating and overheating. By limiting heat ingress, SC-optimized windows maintain indoor temperatures within comfortable ranges (e.g., 20-26°C), enabling reliance on operable vents for rather than constant mechanical cooling, which can lower energy use in mixed-mode buildings. This approach is particularly effective in climates with high exposure, where it reduces the need for active shading interventions and enhances overall without compromising views or . From a life-cycle , the upfront in low-SC glazing is often recouped through energy savings within 3-8 years, depending on climate and building type. U.S. Department of Energy analyses indicate that in cooling-dominated regions, the higher initial costs of advanced glazing (e.g., low-e coatings achieving SC < 0.4) yield paybacks of 3-8 years via reduced utility bills, with savings-to-investment ratios up to 4:1 for SC values around 0.1-0.2 in all-year cooled structures. These benefits extend to long-term operational , as lower HVAC demands decrease maintenance needs and extend equipment life. Case studies illustrate the practical impact of low-SC glazing in achieving energy-efficient outcomes, such as net-zero goals in high-rise offices. In a Platinum-certified 18-story office building in China's hot summer-warm winter zone, double-glazed low-e windows with an SC of 0.35 contributed to an actual energy use intensity (EUI) of 23.9 kWh/m²/year—43% below design estimates—and enabled post-retrofit EUI reductions to 14.74 kWh/m²/year (38% savings) through optimized , supporting net-zero aspirations via integrated . Similar applications in hot-humid climates, like Malaysian high-rises, show SC = 0.4 glazing with devices reducing cooling demands by 5-10%, facilitating compliance with efficiency targets without extensive mechanical augmentation.

Integration with Shading Devices

External shading devices, such as overhangs, vertical fins, and louvers, integrate with glazing systems by intercepting direct solar radiation before it reaches the glass surface, thereby reducing the overall solar heat gain and modifying the shading coefficient (SC) of the fenestration assembly. These static elements provide fixed protection tailored to building orientation and latitude; for instance, horizontal overhangs are particularly effective on south-facing facades in the northern hemisphere, where high summer solar altitudes allow the devices to block a significant portion of direct beam radiation while permitting lower winter sun angles for passive heating. Internal devices like blinds and roller shades complement glazing by absorbing or reflecting short-wave radiation that has already passed through the glass, though they are less efficient at reducing cooling loads compared to external options since heat transfer occurs indoors. The effective SC of a combined glazing-shading system is calculated as the product of the glazing's inherent SC and a shading factor (typically ranging from 0 to 1), which quantifies the device's ability to limit solar exposure based on its geometry, projection depth, and openness. For external devices, the shading factor is often derived from the exposed fraction of the glazing (G), where G accounts for shadow angles and device dimensions—for example, in horizontal overhangs, G = 1 - [sin(vertical shadow angle) × tan(inclination angle)] / (projection length / window height). Vertical fins and louvers follow similar geometric adjustments for horizontal shadow angles, while egg-crate grilles combine both for omnidirectional control, potentially yielding shading factors as low as 0.4 for balanced projections. This multiplicative approach ensures the effective SC reflects real-world performance, with openness in louvers or slats increasing the factor by allowing partial direct transmission. Dynamic shading systems, including automated roller shades and adjustable louvers, offer variable by responding to environmental conditions such as position, time of day, or occupancy, enabling optimization across seasons. These motorized devices can transition from fully open states ( ≈ 0.8–1.0, preserving views and daylight) to closed configurations ( ≈ 0.2–0.3, maximizing rejection), with control algorithms using sensors for precise adjustments that balance and energy use. Unlike static options, dynamic systems require integration with building management controls but provide greater flexibility, such as retracting in winter to enhance gains. Design considerations for integrating shading devices emphasize orientation-specific strategies to maximize benefits while minimizing drawbacks like reduced daylight or obstructed views. South-facing overhangs, for example, can reduce effective by up to 70% during summer months by fully shading direct beam radiation at peak angles, though east- and west-facing applications often necessitate vertical fins or adjustable louvers to address lower-angle morning and afternoon sun. Architects must balance projection ratios (e.g., 0.4–0.5 times dimensions) with aesthetic and functional needs, using tools like solar angle charts to ensure devices enhance rather than compromise indoor illumination.

Standards and Regulations

Key Industry Standards

The American Society of Heating, Refrigerating and Air-Conditioning Engineers () Standard 90.1, titled "Energy Standard for Sites and Buildings Except Low-Rise Residential Buildings," establishes prescriptive requirements for building envelopes in commercial structures, including limits on the solar heat gain coefficient (SHGC) to control solar heat gain, with shading coefficient () allowed as an alternative metric where SC multiplied by 0.86 approximates compliance with SHGC thresholds. For instance, in climate zones 1 through 3, the standard specifies a maximum SHGC of approximately 0.25 for fixed (equivalent to SC ≤ 0.29), ensuring consistent evaluation of glazing performance. The National Fenestration Rating Council (NFRC) Standard 200 outlines procedures for determining the solar heat gain coefficient (SHGC) and visible transmittance (VT) of products at normal incidence, encompassing both simulation-based calculations and physical testing protocols. This standard supports by providing repeatable methods to assess overall performance, including the impact of elements on . Internationally, ISO 15099:2003, "Thermal performance of windows, doors and shading devices—Detailed calculations," defines procedures for computing and total solar energy transmittance (g-value) for glazing systems, enabling harmonized global assessments of and properties. It facilitates consistent modeling of shading device effects, such as internal or external blinds, on and . In the 2020s, revisions to these standards have increasingly incorporated climate-adaptive metrics to align with net-zero goals; for example, 90.1-2022 advances toward net-zero carbon emissions by 2031 through enhanced envelope requirements that emphasize low SHGC values (with SC equivalents) in performance paths. Similarly, NFRC 200 was updated to its 2023 edition to refine simulation accuracy for dynamic shading systems. As of 2025, SC remains a legacy metric in these standards, largely supplanted by SHGC for precise solar heat gain assessment.

Building Code Requirements

The International Energy Conservation Code (IECC) addresses shading coefficient through its prescriptive requirements for the solar heat gain coefficient (SHGC) of , where SHGC ≈ SC × 0.87, allowing SC as an alternative metric in some compliance calculations via conversion. For residential windows in hot-dry climate zones (such as 2B and 3B), the 2024 IECC mandates an area-weighted maximum fenestration SHGC of 0.30 (equivalent to SC ≤ 0.34), with integration into whole-building compliance paths that permit trade-offs across , mechanical, and lighting systems to achieve overall energy targets. Regional variations adapt these metrics to local conditions. California's Title 24 Energy Code requires modeling of SHGC (and corresponding SC equivalents) in performance-based compliance approaches, using software like CBECC-Res to simulate annual energy use and ensure the proposed design meets or exceeds prescriptive baselines. In the European Union's Energy Performance of Buildings Directive (EPBD), member states establish thresholds often expressed as g-value (analogous to SHGC), with requirements varying by country—such as Germany's Building Energy Act (GEG, successor to EnEV) focusing on U-values ≤ 1.3 W/m²K for windows while addressing through overall building energy performance calculations in cooling-dominated regions—to align with national nearly standards. Enforcement of shading coefficient-related requirements typically involves local authority plan reviews to verify compliance documentation, supplemented by third-party certification via National Fenestration Rating Council (NFRC) labels that certify SHGC and U-factor values for installed products. Exceptions are granted for historic buildings to preserve architectural integrity, provided alternative high-performance measures (such as enhanced ) demonstrate equivalent energy savings, and for advanced systems like dynamic shading that achieve superior overall performance. Recent code cycles from 2021 to 2025 have intensified focus on low-SHGC equivalents (with SC conversions where applicable) to support building electrification by minimizing cooling demands and bolstering against , such as intensified ; for instance, the 2024 IECC tightens SHGC limits while incorporating provisions for heat pumps and solar integration in performance paths, emphasizing whole-building net-zero pathways as of November 2025.

References

  1. [1]
    Shading Coefficient (SC) - Cardinal Glass Industries
    May 30, 2024 · The Shading Coefficient (SC) is a measure used to quantify the solar heat gain of glass in comparison to a standard piece of 1/8 inch (3mm) thick clear glass.Missing: ASHRAE | Show results with:ASHRAE
  2. [2]
    [PDF] Chapter 4: The Building Architectural Design
    ■ Shading Coefficient (SC): ratio of solar gain of. a particular glazing compared to the solar gain of clear single and double pane glazing and many tinted ...
  3. [3]
    Shading Coefficient (SC) | UpCodes
    Shading Coefficient (SC) ... the ratio of solar heat gain at normal incidence through glazing to that occurring through 1/8 in. thick clear, double-strength glass ...
  4. [4]
    Shading coefficient (SC) - Thermal Windows
    A measure of the ability of a window or skylight to transmit solar heat, relative to that ability for 1/8-inch clear, double- strength, single glass.Missing: definition | Show results with:definition
  5. [5]
    The Thermal Effects of Solar Gain - Andrew Marsh
    Diffuse radiation from the sky and reflected radiation from the ground and other external surfaces may still get through, but this is a relatively small load ...
  6. [6]
    Things About Low-e Glass - Elite Safety Glass
    Apr 27, 2021 · Low-E shading coefficient can range from 0.2 to 0.7 so that the direct solar energy entering the room can be regulated according to needs.Missing: 0.5 | Show results with:0.5
  7. [7]
    Windows and Glazing | WBDG - Whole Building Design Guide
    ... shading coefficient (SC)." While the terms are related, the shading coefficient of glass is defined as the ratio of the solar heat gain through a given glazing ...
  8. [8]
    [PDF] NBS SP 512 - Office of Justice Programs
    In the 1950's and early '60's, ASH RAE conducted investigations on the effects of solar radiation and the influence of various devices such as double glazing, ...
  9. [9]
    Thermal characteristics of glazing and shading materials
    Vild. Solar heat gain factors and shading coefficient. ASHRAE J, 6 (1964), p. 117. Google Scholar. 3. C.W. Pennington. The shading of sunlit glasses. ASHRAE J., ...
  10. [10]
    [PDF] Determination of Shading Coefficients for Windows Without Shading ...
    ASHRAE Handbook of Fundamentals 1967 Chapter 28. 2. Stephenson. D. G. Tables of solar altitude, azimuth, intensity, and heat gain factors for latitudes from ...Missing: edition | Show results with:edition
  11. [11]
    [PDF] The SCIENCE of Automated Shading
    In the 1950's and 60's, the window glazing of choice was gray or bronze heat-absorbing glass. It had a shading coefficient, or SC—the measure of the heat ...<|control11|><|separator|>
  12. [12]
    How the 1970s US Energy Crisis Drove Innovation - History.com
    Oct 17, 2022 · In the 1970s, the Energy Department funded research to create low-emissivity window coatings, which are now found on many clear glass buildings.Missing: development 1980s
  13. [13]
    Energy-Saving Windows A Legacy Of '70s Oil Crisis - NPR
    Oct 15, 2008 · The technology is called low-emissivity window coatings, and these invisible films are the reason that architects in American cities are ...
  14. [14]
    Standards, Guidelines, Codes - Energy-Models.com
    In 1974 ASHRAE introduced Standard 90 (STD90-74) for buildings. Later this standard was organized as STD90.1 for commercial buildings and STD90.2 for ...
  15. [15]
    The Death of the Shading Coefficient ASHRAE Journal, March 1991
    In the ASHRAE 1989 Handbook of Fundamentals it states that for standard summer conditions F for the standard reference glazing is 0.87. In this case SC ...Missing: edition | Show results with:edition
  16. [16]
    Glass Lab test: SHGC, shading coefficient (SC), U-value & optical ...
    SC = SHGC / 0.87; SHGC = 0.87 x SC. Here, 0.87 is the nominal SHGC of a clear glass. Shading coefficient is a relative scale in comparison with a clear glass.
  17. [17]
    Window Calculation Module: Engineering Reference — EnergyPlus ...
    SHGC combines directly transmitted solar radiation and radiation absorbed by the glass which flows inward. These have different implications for space heating/ ...
  18. [18]
    Performance Value Terms | Guardian Glass
    Shading Coefficient (sc) is Solar Heat Gain Coefficient divided by 0.87. It is a measure of the solar heat gain referenced to 3 mm clear glass which has the ...Missing: formula | Show results with:formula
  19. [19]
    Şişecam Tinted Float Glass
    Shading Coefficient: Comparison of the total solar energy transmittance with 3 mm clear glass. A lower shading coefficient means better solar control. Heat ...
  20. [20]
    [PDF] Calculating the Effect of External Shading on the Solar Heat Gain ...
    We propose two new indicators, the adjusted Solar Heat. Gain Coefficient (aSHGC) which accounts for external shading while calculating the SHGC of a window, and ...
  21. [21]
    SHGC,TSER,SC and G-value - Linshang
    Apr 23, 2019 · SC: Shading Coefficient​​ It is defined as the ratio of solar radiation at a given wavelength and angle of incidence passing through a glass unit ...
  22. [22]
    Energy Performance Ratings for Windows, Doors, and Skylights
    Solar heat gain coefficient (SHGC) is the fraction of solar ... The lower the SHGC, the less solar heat it transmits and the greater its shading ability.
  23. [23]
    [PDF] International Window Standards - Energy Ratings - BC Housing
    This standard defines various other parameters, including the Shading Coefficient (SC), defined as SC = g / 0.87. This standard references. EN 673 for ...
  24. [24]
    [PDF] NFRC Behind the Glass
    Before NFRC officially formed, some states were beginning to demand rating and labeling standards for windows sold within their borders. California was one of ...
  25. [25]
    5.8.2.4 Solar Heat Gain Coefficient. - ICC Digital Codes
    1. Shading coefficient (SC) of the center-of-glass multiplied by 0.86 shall be an acceptable alternative for determining compliance with the SHGC requirements.
  26. [26]
  27. [27]
    [PDF] Impacts of Shading and Glazing Combinations on Residential ...
    A parametric study of annual energy use is presented showing the impacts of glazing type, architectural shading, site shading, and building orientation. It is ...
  28. [28]
    [PDF] Effectiveness of solar shading for an office building - GovInfo
    The impact of solar shading of windows on building energy consumption, energy costs and occupant comfort is examined for a typical office building. Measure ...
  29. [29]
    [PDF] Passive Design Toolkit
    For commercial buildings, use either clear glass with effective external shading elements or dark or reflective glass (low shading coefficient) to control.
  30. [30]
    [PDF] Passive Solar Design Strategies: Guidelines for Home Building
    shading coefficient. The shading coefficient is a number between zero and one that indicates how much solar heat makes it through the window compared to an ...
  31. [31]
    Windows: Understanding Energy Efficient Performance
    These improvements boost energy efficiency by nearly 100% over clear glass ... Manufacturers have long used the term shading coefficient (SC) to ...
  32. [32]
    [PDF] Assessment of the Potential of High-Performance Buildings to ...
    Feb 22, 2019 · This paper presents a case study on how a large high-rise office building located in the hot summer ... of 2.36 W/(m2 K) and a shading coefficient ...
  33. [33]
    (PDF) Potential of Shading Devices and Glazing Configurations on ...
    Aug 9, 2025 · ... High-rise Office Buildings in Hot-humid Climates: The Case of Malaysia ... Shading Coefficient 0.4, U-value 3.35 W/m. 2. k. Indoor temperature - 23 ...
  34. [34]
    Sun Control and Shading Devices | WBDG
    The shading coefficient (SC) of a glazing indicates the amount of solar heat gain that is admitted into a building relative to a single-glazed reference glass.
  35. [35]
    [PDF] CODE ON ENVELOPE THERMAL PERFORMANCE FOR BUILDINGS
    To facilitate the calculation of the effective shading coefficient of external shading devices, the intensities of diffuse, direct and total radiation.
  36. [36]
    Solar shading performance of window with constant and dynamic ...
    May 1, 2017 · The shading devices are more and more employed to reduce solar radiation passing through window in hot seasons. Solar heat gain coefficient ( ...<|separator|>
  37. [37]
  38. [38]
    [PDF] ANSI/ASHRAE/IES Standard 90.1-2022 (I-P) - NCLOSE
    Feb 2, 2024 · ASHRAE Standards and Guidelines are established to assist industry and the public by offering a uniform method of testing for rating purposes, ...
  39. [39]
    [PDF] NFRC 200-2023[E0A5E0A6] - National Fenestration Rating Council
    To specify a method for calculating solar heat gain coefficient (SHGC) and visible transmittance (VT) at normal (perpendicular) incidence for fenestration ...
  40. [40]
  41. [41]
    [PDF] ISO 15099 - iTeh Standards
    Nov 15, 2003 · ISO 15099 is about the thermal performance of windows, doors and shading devices, specifically detailed calculations.
  42. [42]
    ASHRAE Reaffirms Net Zero Energy Goals
    Standard 90.1 has also committed to reaching net zero carbon and net zero energy by 2031.
  43. [43]
    [PDF] ANSI/ASHRAE/IES Standard 90.1-2022: Energy Savings Analysis
    Building models were analyzed in standardized climate zones described in ASHRAE Standard 169-2013. (ASHRAE 2013). ... coefficient of -0.47%/°C. Performance shall ...
  44. [44]
    CHAPTER 4 RE RESIDENTIAL ENERGY EFFICIENCY
    The area-weighted maximum fenestration SHGC permitted in Climate Zones 0 through 3 shall be 0.30. Equation 4-2. 3. For each dwelling unit with ...
  45. [45]
    Solar Heat Gain Coefficient | UpCodes
    Shading coefficient (SC) of the center-of-glass multiplied by 0.86 shall be an acceptable alternative for determining compliance with the SHGC requirements ...Missing: IECC | Show results with:IECC
  46. [46]
    [PDF] 2022 Building Energy Efficiency Standards
    The 2022 Building Energy Efficiency Standards cover residential and nonresidential buildings, are for Title 24, Part 6, and include energy, water, and indoor ...
  47. [47]
    2022 BUILDING ENERGY EFFICIENCY STANDARDS, TITLE 24 ...
    SUBCHAPTER 2 - ALL OCCUPANCIES--MANDATORY REQUIREMENTS FOR THE MANUFACTURE, CONSTRUCTION AND INSTALLATION OF SYSTEMS, EQUIPMENT AND BUILDING COMPONENTS.
  48. [48]
    The European Commission releases the EPBD guidance on the ...
    Jul 1, 2025 · The European Commission's guidance aims to address this issue by encouraging Member States to establish minimum requirements based on the U-value and g-value ( ...
  49. [49]
    [PDF] Energy Savings Analysis: 2024 IECC for Residential Buildings
    Dec 20, 2024 · REPI-089 increases pipe insulation requirements for domestic hot water systems. The insulation requirement increases from R-3 to R-7 for ¾ ...
  50. [50]
    [PDF] Methodology for Developing the REScheck
    Note that the shading coefficient is fixed at 0.88, regardless of the window U-factor. ... For changes relevant to the 2006 IECC, 2007. IECC, and 2009 IECC, view ...