Cardiac cycle
The cardiac cycle refers to the coordinated sequence of mechanical and electrical events that occur during one complete heartbeat, driving the propulsion of blood through the heart's chambers and into the systemic and pulmonary circulations.[1] It consists of two primary phases: systole, the contraction of the ventricles to eject blood, and diastole, the relaxation and filling of the ventricles with blood.[2] At a typical resting heart rate of 75 beats per minute, the entire cycle lasts approximately 0.8 seconds, with systole occupying about one-third (0.27 seconds) and diastole the remaining two-thirds.[2] During systole, the process begins with isovolumetric contraction, where ventricular pressure rises rapidly after the closure of the atrioventricular (AV) valves (mitral and tricuspid), producing the first heart sound (S1), without any change in ventricular volume.[1] This is followed by the ejection phase, divided into rapid ejection (where most of the stroke volume is expelled) and reduced ejection, as the semilunar valves (aortic and pulmonic) open and blood is forced into the aorta and pulmonary artery, peaking at pressures of about 120 mmHg in the left ventricle and 25 mmHg in the right.[2] The left ventricle ejects a stroke volume of approximately 70 mL from an end-diastolic volume of about 120 mL, resulting in an ejection fraction of approximately 60%.[3] Diastole commences with isovolumetric relaxation, marked by the closure of the semilunar valves (producing the second heart sound, S2) and a sharp drop in ventricular pressure, again with no volume change, until the AV valves reopen.[4] Ventricular filling then occurs in three subphases: rapid filling (about 70-80% of ventricular filling occurs passively due to pressure gradients and ventricular suction), diastasis (slower filling as pressures equilibrate), and atrial systole (or "atrial kick," contributing an additional ~20% of filling via atrial contraction).[5] End-diastolic ventricular pressures are low, around 5-12 mmHg in the left ventricle and 0-8 mmHg in the right, ensuring efficient preload for the next cycle.[2] These phases are tightly regulated by the cardiac conduction system, with electrical impulses from the sinoatrial node initiating atrial depolarization (P wave on ECG), followed by ventricular depolarization (QRS complex) and repolarization (T wave), ensuring synchronized contraction.[4] The cardiac cycle's efficiency is vital for maintaining cardiac output—heart rate multiplied by stroke volume—typically 5-6 L/min at rest, and its disruptions underpin conditions like heart failure or valvular disease, making it a cornerstone of cardiovascular physiology and clinical evaluation.[1]Overview and Basics
Definition and Importance
The cardiac cycle refers to the complete sequence of electrical and mechanical events in the heart from the onset of one heartbeat to the beginning of the next, encompassing periods of relaxation (diastole) and contraction (systole) in both the atria and ventricles.[6] This cycle coordinates the alternating filling and emptying of the heart chambers to propel blood through the circulatory system.[7] The cardiac cycle is triggered by electrical impulses that initiate the mechanical phases, ensuring synchronized activity across the heart.[8] The primary importance of the cardiac cycle lies in its role in maintaining continuous, unidirectional blood flow, which supports both pulmonary and systemic circulations essential for oxygen delivery and nutrient distribution throughout the body.[9] During diastole, the heart chambers relax and fill with blood, while systole propels this blood forward, preventing stagnation and ensuring efficient circulation at rest (approximately 5 liters per minute) or during increased demand.[9] This process relies on the four heart valves to enforce one-way flow and avoid backflow: the mitral and tricuspid valves (atrioventricular valves) guard the entrances to the ventricles, opening during atrial contraction to allow filling and closing during ventricular contraction to direct blood outward.[7] In the right side of the heart, deoxygenated blood flows from the right atrium to the right ventricle and then into the pulmonary artery for oxygenation in the lungs (pulmonary circulation), facilitated by the pulmonary valve.[9] On the left side, oxygenated blood moves from the left atrium to the left ventricle and out through the aorta to supply the body's tissues (systemic circulation), with the aortic valve ensuring forward propulsion without regurgitation.[7] Disruptions in the cardiac cycle, such as valve dysfunction, can impair this coordinated flow, underscoring its critical function in sustaining life.[8]Duration and Heart Rate Relation
The cardiac cycle typically lasts approximately 0.8 seconds at a resting heart rate of 75 beats per minute (bpm), during which diastole occupies about 0.5 seconds and systole about 0.3 seconds, allowing more time for ventricular filling under resting conditions.[2][10] In adults, the normal resting heart rate ranges from 60 to 100 bpm, primarily determined by the spontaneous firing rate of the sinoatrial (SA) node, the heart's primary pacemaker located in the right atrium.[11][12] The duration of the cardiac cycle is inversely related to heart rate and can be calculated using the formula: cycle duration (in seconds) = 60 / heart rate (in bpm).[13] As heart rate increases, such as to 180 bpm during intense exercise, the total cycle shortens to approximately 0.33 seconds, with diastole reducing disproportionately more than systole to prioritize ejection while limiting filling time.[2][14] This adaptive shortening ensures cardiac output matches physiological demands but can impair diastolic function if sustained at very high rates.[15]Cardiac Electrophysiology
Conduction System Components
The cardiac conduction system comprises specialized cardiac tissues that generate and propagate electrical impulses to coordinate myocardial contraction during the cardiac cycle. This system ensures synchronized atrial and ventricular activation, with its components consisting of autorhythmic and conducting cells distinct from the contractile cardiomyocytes that form the bulk of the heart muscle. Autorhythmic cells, found primarily in the pacemaker regions, exhibit spontaneous depolarization due to unique ion channel properties, allowing them to initiate action potentials without external stimulation.[16] In contrast, contractile cardiomyocytes in the conduction pathways rapidly propagate these impulses but do not generate them independently.[17] The sinoatrial (SA) node, located at the junction of the superior vena cava and the right atrium, serves as the primary pacemaker of the heart. Composed of autorhythmic cells, the SA node generates impulses at an intrinsic rate of 60 to 100 beats per minute under normal conditions, establishing the baseline heart rhythm.[18] These cells spontaneously depolarize through a gradual influx of sodium and calcium ions during phase 4 of the action potential, leading to rhythmic firing that spreads across the atria.[19] The atrioventricular (AV) node, situated in the inferior interatrial septum near the tricuspid valve annulus, receives the impulse from the SA node and introduces a critical delay. This delay, approximately 0.1 seconds, allows complete atrial contraction before ventricular activation begins, optimizing ventricular filling.[20] Like the SA node, the AV node consists of autorhythmic cells with slow conduction properties, acting as a secondary pacemaker if the SA node fails, though at a slower intrinsic rate of 40 to 60 beats per minute.[19] From the AV node, the impulse travels to the bundle of His, a compact bundle of specialized conducting fibers that penetrates the fibrous cardiac skeleton and penetrates into the interventricular septum. The bundle of His divides into the left and right bundle branches, which extend along the endocardial surface of the interventricular septum to distribute the signal to the ventricles. These branches are composed of contractile cardiomyocytes modified for fast conduction, ensuring efficient spread to the ventricular myocardium.[21] The Purkinje fibers, arising from the terminal portions of the bundle branches, form a subendocardial network that ramifies throughout the ventricular walls. These fibers, also made of modified contractile cardiomyocytes, provide rapid and nearly simultaneous activation of the ventricular myocardium from apex to base, promoting efficient ejection. With conduction velocities significantly higher than in ordinary ventricular muscle—up to 2 to 3 meters per second in Purkinje fibers versus 0.3 to 0.4 meters per second in myocardium—they minimize the time for ventricular depolarization.[22] This anatomical arrangement of the conduction system components collectively orchestrates the electrical events that trigger mechanical systole.[23]Impulse Propagation and ECG Correlation
The cardiac impulse originates in the sinoatrial (SA) node, where it initiates depolarization that spreads rapidly across the atria, completing atrial activation in approximately 0.09 seconds.[24] This propagation occurs at a conduction velocity of about 0.5 m/s through atrial myocardium. Following atrial depolarization, the impulse reaches the atrioventricular (AV) node, where it encounters a deliberate delay of roughly 0.1 seconds to allow complete atrial contraction before ventricular activation begins; this delay occurs due to slower conduction velocity of approximately 0.05 m/s in the AV node.[24] The impulse then accelerates through the bundle of His and bundle branches at around 2 m/s, before distributing via the Purkinje fibers at up to 4 m/s to activate the ventricular myocardium from endocardium to epicardium.[24] Ventricular activation commences at the septum approximately 0.16 seconds after SA node firing and completes across the entire ventricles by about 0.23 seconds, ensuring synchronized contraction.[24] In cardiac myocytes, the propagating impulse triggers an action potential characterized by five phases. Phase 0 involves rapid depolarization driven by influx of sodium ions (Na⁺) through voltage-gated Na⁺ channels, shifting the membrane potential from approximately -90 mV to +20 mV.[25] Phase 1 features early repolarization via transient outward potassium currents and Na⁺ channel inactivation. Phase 2, the plateau phase, is maintained by calcium ion (Ca²⁺) influx through L-type Ca²⁺ channels, balanced by potassium efflux, prolonging depolarization to allow sustained contraction.[25] Phase 3 entails repolarization through delayed rectifier potassium currents, returning the membrane to resting potential. Phase 4 represents the diastolic resting state, dominated by inward rectifier potassium currents. This Ca²⁺ influx during phase 2 triggers excitation-contraction coupling, where Ca²⁺ release from the sarcoplasmic reticulum binds to troponin C, exposing myosin-binding sites on actin filaments and enabling actin-myosin cross-bridge formation for contraction.[26] The electrocardiogram (ECG) records these electrical events as characteristic waveforms. The P wave corresponds to atrial depolarization initiated by the SA node impulse.[27] The PR interval, measuring 0.12 to 0.20 seconds, encompasses the time from P wave onset to QRS complex onset, reflecting the AV nodal delay and propagation to the ventricles.[27] The QRS complex, lasting 0.06 to 0.10 seconds, represents rapid ventricular depolarization via the bundle branches and Purkinje system.[27] The ST segment follows the QRS and aligns with the action potential plateau (phase 2), indicating the period of ventricular contraction before repolarization. The T wave depicts ventricular repolarization during phase 3. These ECG features temporally precede and coordinate with the mechanical phases of atrial and ventricular systole.[27]Mechanical Phases
Diastole
Diastole represents the relaxation phase of the cardiac cycle, during which the ventricles fill with blood in preparation for the subsequent contraction. This phase is essential for restoring ventricular volume and ensuring adequate preload for effective ejection. It is triggered by ventricular repolarization, corresponding to the T wave on the electrocardiogram.[1] Early diastole consists of two key subphases: isovolumetric relaxation and rapid filling. During isovolumetric relaxation, the ventricles relax following semilunar valve closure, leading to a drop in ventricular pressure while the atrioventricular (AV) valves remain closed, resulting in no change in ventricular volume. This brief period allows pressures to equilibrate sufficiently for the AV valves to open. Once the AV valves open, rapid filling ensues, driven by the pressure gradient between the atria and ventricles, which accounts for approximately 70-80% of ventricular filling.[4][1] This is followed by diastasis, a period of slower filling as atrial and ventricular pressures equilibrate, contributing a smaller portion to passive filling.[1] At rest, with a heart rate of around 75 beats per minute, diastole typically lasts about 0.5 seconds, comprising roughly two-thirds of the total cardiac cycle duration of 0.8 seconds. As heart rate increases, the duration of diastole shortens disproportionately compared to systole, potentially limiting filling time. During this phase, the atria remain relaxed and serve as low-pressure reservoirs, facilitating passive blood transfer to the ventricles. Ventricular compliance, the ability of the ventricular walls to stretch and accommodate incoming blood, plays a critical role in this process; optimal compliance ensures efficient filling without excessive pressure rise. The resulting end-diastolic volume for the left ventricle is normally around 130 mL, representing the preload for the next systolic phase.[2][2][28]Atrial Systole
Atrial systole occurs during the late phase of ventricular diastole, immediately preceding ventricular systole, and is triggered by the P wave on the electrocardiogram, which corresponds to atrial depolarization.[1] This phase typically lasts about 0.1 seconds in a normal cardiac cycle at rest, ensuring the completion of ventricular filling before the ventricles begin to contract.[1] During atrial systole, the atria undergo active contraction, which elevates intra-atrial pressure and propels blood through the open atrioventricular (AV) valves—the mitral valve on the left and the tricuspid valve on the right—into the relaxed ventricles.[5] The semilunar valves (aortic and pulmonary) remain closed at this stage, preventing any backflow into the atria or great vessels, while the AV valves facilitate unidirectional flow due to the pressure gradient created by atrial contraction.[1] This mechanical action ejects the atrial contents. The primary contribution of atrial systole is the "atrial kick," which augments ventricular end-diastolic volume by an additional 20-30% beyond the passive filling achieved earlier in diastole, thereby optimizing preload and stroke volume.[5] This boost is particularly vital at higher heart rates, where reduced diastolic duration limits passive filling time, helping to maintain effective ventricular output and cardiac performance.[29] Without this atrial contribution, stroke volume could decrease significantly, underscoring its essential role in normal hemodynamics.[29]Ventricular Systole
Ventricular systole represents the active contraction phase of the cardiac cycle in which the ventricles generate force to eject blood into the pulmonary trunk and aorta, propelling it to the lungs and systemic circulation, respectively. This phase begins immediately following atrial systole and is characterized by a rise in intraventricular pressure exceeding that in the atria and great arteries. It is initiated by the QRS complex, corresponding to ventricular depolarization. The total duration of ventricular systole at rest is approximately 0.3 seconds, accounting for about one-third of the cardiac cycle at a heart rate of 75 beats per minute.[30] Ventricular systole consists of two main subphases: isovolumetric contraction and ejection. During isovolumetric contraction, which lasts about 0.05 seconds, the ventricles contract with all heart valves closed—the atrioventricular valves having just shut and the semilunar valves not yet open—resulting in no change in ventricular volume while intraventricular pressures rapidly increase to overcome arterial pressures. This brief period ensures efficient pressure buildup without backflow. The ejection subphase follows, lasting roughly 0.25 seconds, during which the semilunar valves open once ventricular pressure exceeds arterial pressure, allowing blood to be expelled. Ejection is further divided into a rapid initial phase, where blood flow is maximal due to peak contractility, and a reduced phase toward the end, as ventricular pressure begins to decline but momentum sustains forward flow.[30][1] The ejection phase propels the stroke volume, typically around 70 mL in a healthy adult at rest, representing the difference between end-diastolic and end-systolic ventricular volumes. The ejection fraction, calculated as stroke volume divided by end-diastolic volume, normally ranges from 55% to 70%, indicating the proportion of filled blood effectively pumped out and serving as a key measure of ventricular efficiency. During ventricular systole, the atria are in their relaxation phase, remaining passive to avoid interference with ventricular output. The right and left ventricles contract nearly simultaneously due to synchronized electrical activation, yet they face distinct afterloads: the right ventricle pumps against the lower-pressure pulmonary circulation (approximately 25 mmHg systolic), while the left contends with the higher systemic arterial pressure (about 120 mmHg systolic), influencing their respective ejection dynamics.[31][1]Hemodynamics
Pressure Changes
The cardiac cycle is characterized by dynamic fluctuations in pressure within the heart's chambers and major vessels, which drive the unidirectional flow of blood. These pressure variations occur in a coordinated sequence, ensuring efficient filling and ejection of blood while preventing backflow through valvular mechanisms. Pressures are typically measured in millimeters of mercury (mmHg) and differ markedly between the left and right sides of the heart due to the distinct vascular beds they supply.[1] Key pressures in the cardiac cycle reflect the low-pressure filling phase and high-pressure ejection phase. In the atria, mean pressures remain relatively low: the right atrium averages 4-5 mmHg, while the left atrium is slightly higher at about 8-10 mmHg, accommodating venous return from the systemic and pulmonary circulations, respectively.[1][9] Ventricular pressures vary more dramatically; during diastole, both ventricles maintain near-atmospheric levels, with the right ventricle at 0-5 mmHg and the left at 0-10 mmHg, allowing passive filling.[1] In systole, the right ventricle peaks at approximately 25 mmHg to overcome pulmonary artery resistance, whereas the left ventricle reaches about 120 mmHg to propel blood into the systemic circulation.[1] Arterial pressures follow ventricular ejection patterns: the aorta exhibits systolic/diastolic values of 120/80 mmHg, and the pulmonary artery 25/10 mmHg, with diastolic levels sustained by elastic recoil in these vessels.[1][9] These pressures evolve through distinct phases of the cycle, closely linked to atrioventricular (AV) and semilunar valve states. During diastole, ventricular relaxation causes chamber pressures to drop below atrial levels (e.g., left ventricular pressure falls to 0-10 mmHg from the left atrial 8-10 mmHg), opening the AV valves (mitral and tricuspid) and enabling rapid ventricular filling.[9] Atrial systole then boosts atrial pressure briefly to further fill the ventricles.[7] In early systole, isovolumetric contraction occurs as ventricular pressures rise rapidly (e.g., left ventricle from 10 mmHg to over 80 mmHg) with all valves closed, building tension without volume change until exceeding arterial pressures, which opens the semilunar valves (aortic and pulmonary) for ejection.[1][9] Late systole features peak ventricular pressures driving forward flow, followed by isovolumetric relaxation where ventricular pressures plummet (e.g., left ventricle from 120 mmHg to below 10 mmHg) while semilunar valves close, preventing reflux until AV valves reopen.[1][7] Notably, the left heart operates at substantially higher pressures than the right, a adaptation to the greater resistance in the systemic circulation compared to the low-resistance pulmonary circuit. For instance, left ventricular systolic pressure (120 mmHg) is roughly five times that of the right (25 mmHg), and aortic diastolic pressure (80 mmHg) far exceeds pulmonary (10 mmHg), ensuring adequate perfusion to high-demand systemic tissues while minimizing pulmonary edema risk.[1][7] This asymmetry underscores the heart's dual-pump functionality, with left-sided pressures reflecting the workload against arteriolar resistance and right-sided ones suited to gas exchange in the lungs.[9]| Chamber/Vessel | Diastolic Pressure (mmHg) | Systolic Pressure (mmHg) |
|---|---|---|
| Right Atrium | 0-5 | N/A (low throughout) |
| Left Atrium | 8-10 | N/A (low throughout) |
| Right Ventricle | 0-5 | 25 |
| Left Ventricle | 0-10 | 120 |
| Pulmonary Artery | 10 | 25 |
| Aorta | 80 | 120 |