Full width at half maximum

The full width at half maximum (FWHM) is a quantitative measure used to describe the width of a or in various scientific contexts, defined as the separation between the two points on a where the or is exactly half of its maximum value. This parameter is particularly valuable because it provides a straightforward, shape-independent way to assess the breadth of features like spectral lines, resonance s, or Gaussian s without requiring complex fitting. In physics and , FWHM serves as a key indicator of , where narrower widths signify higher ability to distinguish closely spaced features, such as in lines or instrumental response functions. For instance, in the analysis of or Breit-Wigner line shapes—common in for unstable particle decays or resonances—the FWHM directly relates to the lifetime or decay rate of the , with narrower profiles indicating longer-lived states. Similarly, in and astronomy, it characterizes beam spreads or point spread functions, as in primary beams where the FWHM defines the effective . FWHM is also integral to and , often applied to Gaussian profiles where it approximates 2.355 times the standard deviation (σ), aiding in the evaluation of data spread or filter bandwidths. In medical imaging, such as magnetic resonance spectroscopy, it measures resonance linewidths to assess spectral quality and tissue properties. Its ubiquity stems from computational simplicity: it can be directly extracted from experimental data by identifying the half-maximum points, making it robust for both theoretical modeling and practical measurements across disciplines like and .

Definition and Properties

Definition

The full width at half maximum (FWHM) is defined as the width of a peaked or signal measured at the points where its value equals half of the maximum . This parameter quantifies the extent of the central portion of the by identifying the two points where the intensity or height is half the maximum value, and taking the distance between them along the independent variable axis, such as , , time, or position. It applies broadly to any unimodal or probability density exhibiting a single prominent , serving as a robust indicator of width without requiring assumptions about the underlying shape. The concept originated in the field of as a standard measure for characterizing the broadening of lines, reflecting factors like or physical processes such as Doppler effects. Over time, it was adopted in statistics and to describe the spread or variability in peaked distributions, providing an intuitive metric for that complements measures like standard deviation. For instance, in the Gaussian distribution, commonly encountered in natural phenomena, the FWHM offers a practical way to gauge dispersion. Visually, consider a generic bell-shaped representing a signal versus some : the rises to a maximum, and the FWHM is determined by drawing a horizontal line at half the height, which intersects the at two points; the separation between these intersections captures the core width of the feature. This approach emphasizes the region's where the signal is most significant, effectively quantifying spread or duration in a manner independent of the precise or extension. FWHM differs from other width measures, such as the full width at base (FWB), which extends from one baseline intersection to the other across the entire , including extended tails that may arise from or secondary effects. By focusing solely on the half-maximum level, FWHM avoids overestimation from outliers or low-level broadening, making it particularly valuable for peaked profiles where the central region dominates the functional behavior.

Key properties

The full width at half maximum (FWHM) exhibits invariance under vertical scaling, such that multiplying the entire by a constant factor to alter its height leaves the FWHM unchanged, as the half-maximum level scales proportionally with the . This property renders FWHM particularly advantageous for analyzing signals where variations occur due to experimental conditions, such as differing sample concentrations or detector sensitivities, without affecting the width assessment. For instance, in , this ensures consistent quantification of broadening mechanisms regardless of signal strength. In scenarios involving , such as when a true signal is broadened by an instrument response function, the FWHM of the resultant approximates the of the sum of the squares of the individual FWHMs for profiles with similar shapes, like Gaussians. This approximate additivity facilitates the of instrumental effects from intrinsic properties, enabling more accurate determination of underlying widths in fields like . FWHM demonstrates sensitivity to peak asymmetry, where non-symmetric profiles—often featuring extended tails on one side—yield a larger measured width at half maximum than their symmetric equivalents, capturing the influence of factors like interactions or chemical shifts. This characteristic highlights deviations from ideal symmetric broadening, providing diagnostic value for identifying asymmetries in experimental data. Additionally, the units of FWHM match those of the , such as nanometers for in optical spectra or seconds for temporal pulses, ensuring direct interpretability in context-specific measurements.

Mathematical Formulation

General expression

The full width at half maximum (FWHM) of a continuous unimodal f(x) is defined as the distance between the two points on either side of the where the function value equals half its maximum . Specifically, if f(x) attains its maximum value f_{\max} at position x_0, then the FWHM is given by \Delta x = x_{1/2}^+ - x_{1/2}^-, where x_{1/2}^- and x_{1/2}^+ are the solutions to the equation f(x_{1/2}^\pm) = f_{\max}/2 with x_{1/2}^- < x_0 < x_{1/2}^+. To compute the FWHM, first identify the maximum value f_{\max} and its location x_0. Then, solve the equation f(x) - f_{\max}/2 = 0 numerically to find the roots x_{1/2}^- and x_{1/2}^+ flanking the peak, and subtract these points to obtain the width. For functions normalized such that f(x) \leq 1 with f(x_0) = 1, the half-maximum level simplifies to 0.5, so the roots satisfy f(x_{1/2}^\pm) = 0.5. This definition assumes an isolated peak; for functions with multiple or overlapping peaks, the FWHM applies only after isolating the target peak through techniques such as baseline subtraction or multi-component curve fitting to deconvolve contributions. For instance, the admits a closed-form expression for its FWHM.

Relations to other parameters

The full width at half maximum (FWHM) serves as a measure of dispersion in peaked functions and probability distributions, relating directly to other parameters that characterize spread or scale. In the , defined by the probability density function f(x) = \frac{1}{\sigma \sqrt{2\pi}} \exp\left( -\frac{(x - \mu)^2}{2\sigma^2} \right), the FWHM is given exactly by $2 \sqrt{2 \ln 2} \, \sigma \approx 2.355 \sigma, where \sigma is the . This connection highlights FWHM as approximately 2.355 times the standard deviation, providing a practical link between the robust width metric and the variance-based measure of dispersion. For the Lorentzian (or Cauchy) distribution, with density f(x) = \frac{1}{\pi \gamma} \frac{1}{1 + \left( \frac{x - \mu}{\gamma} \right)^2 }, the FWHM equals $2\gamma, where \gamma denotes the half-width at half-maximum parameter. This exact equality underscores the FWHM's role as the defining scale in Lorentzian profiles, common in resonance phenomena. A related measure, the full width at quarter maximum (FWQM), for a Gaussian is $2 \sqrt{2 \ln 4} \, \sigma = 4 \sqrt{\ln 2} \, \sigma \approx 3.330 \sigma, yielding FWQM \approx 1.414 \times FWHM. In spectroscopy, the FWHM approximates the equivalent width (EW) for narrow line profiles, where EW \approx (line depth) \times FWHM, as the rectangular area of height equal to the maximum absorption and width equal to FWHM closely matches the integrated line area. This simplification holds when the line is unresolved and symmetric, facilitating quick estimates of line strength without full integration. For the Voigt profile, arising as the convolution of Gaussian and Lorentzian components, the FWHM combines both contributions but lacks a simple closed form. In parameterized families of distributions, such as location-scale families, the FWHM scales linearly with the scale parameter, preserving the shape while proportionally adjusting the width; for instance, if a distribution is scaled by a factor c > 0, its FWHM multiplies by c. This proportionality ensures FWHM's utility as a scale-invariant descriptor up to the scaling factor, applicable across rescaled variants like standardized normals or gamma distributions with fixed shape.

Applications in Distributions

Gaussian distribution

The Gaussian distribution, or , is defined by its f(x) = \frac{1}{\sigma \sqrt{2\pi}} \exp\left( -\frac{(x - \mu)^2}{2\sigma^2} \right), where \mu is the () and \sigma > 0 is the standard deviation (). To derive the full width at half maximum (FWHM), identify the points where f(x) equals half its maximum value. The maximum density occurs at x = \mu, with f(\mu) = \frac{1}{\sigma \sqrt{2\pi}}. Setting f(x) = \frac{1}{2} f(\mu) simplifies to \exp\left( -\frac{(x - \mu)^2}{2\sigma^2} \right) = \frac{1}{2}. Taking the natural logarithm yields \frac{(x - \mu)^2}{2\sigma^2} = \ln 2, so |x - \mu| = \sigma \sqrt{2 \ln 2}. Thus, the FWHM is the between these points: \text{FWHM} = 2 \sigma \sqrt{2 \ln 2} \approx 2.3548 \sigma. This measure quantifies the effective width of the bell-shaped curve, providing a practical indicator of spread that approximates the range containing a substantial portion of the probability mass, such as roughly 76% within \mu \pm \frac{\text{FWHM}}{2}, which aids in statistical inference like estimating confidence intervals. For example, with \sigma = 1 and \mu = 0, the FWHM is approximately 2.355, spanning from x \approx -1.177 to x \approx 1.177 where the density drops to half maximum.

Lorentzian distribution

The distribution, also known as the in , has the f(x) = \frac{\gamma}{\pi \left[ (x - x_0)^2 + \gamma^2 \right]}, where x_0 is the representing the , and \gamma > 0 is the that corresponds to the half-width at half-maximum. To derive the full width at half maximum (FWHM), first note that the maximum value of the density occurs at x = x_0, where f(x_0) = \frac{1}{\pi \gamma}. The half-maximum value is thus \frac{1}{2\pi \gamma}. Setting f(x) = \frac{1}{2\pi \gamma} yields \frac{\gamma}{\pi \left[ (x - x_0)^2 + \gamma^2 \right]} = \frac{1}{2\pi \gamma}, which simplifies to (x - x_0)^2 + \gamma^2 = 2\gamma^2, so (x - x_0)^2 = \gamma^2 and x - x_0 = \pm \gamma. Therefore, the points at half-maximum are separated by $2\gamma, giving FWHM = $2\gamma. Unlike the Gaussian distribution, the Lorentzian exhibits heavy tails that decay as $1/x^2, leading to undefined mean and all higher moments except in a principal value sense, with the variance specifically diverging to infinity. As a result, the FWHM serves as the primary measure of scale and spread for the Lorentzian, rather than variance or standard deviation, which are unavailable. In physics, the Lorentzian distribution commonly describes resonance phenomena, such as the lineshape of unstable particles or atomic transitions, where the parameter \gamma (or \Gamma = 2\gamma as the full width) relates to the lifetime \tau of the resonant state via the energy-time uncertainty principle: \Delta E \cdot \Delta t \geq \hbar/2, with \Delta E \approx \hbar / \tau corresponding to the energy width \Gamma.

Applications in Physics and Engineering

Spectroscopy

In spectroscopy, the full width at half maximum (FWHM) quantifies the broadening of spectral lines, providing insight into the physical processes affecting or molecular transitions. It is typically measured in units of (e.g., ) or (e.g., GHz), representing the width of the profile where the signal drops to half its peak value. This parameter is crucial for characterizing the and lifetime of excited states in or spectra. Spectral line broadening arises from various mechanisms, each contributing to the observed FWHM. Doppler broadening, due to the thermal motion of emitting or absorbing particles, results in a Gaussian profile with FWHM given by \Delta \nu_D = \frac{2\nu_0}{c} \sqrt{2kT \ln 2 / m}, where \nu_0 is the central , c the , k Boltzmann's , T , and m the particle . Natural broadening, stemming from the finite lifetime of quantum states via the , produces a Lorentzian profile with FWHM \Delta \nu_N = \frac{1}{2\pi \tau}, where \tau is the excited state lifetime. Pressure broadening, caused by collisions in dense gases, also yields a Lorentzian shape, with FWHM proportional to the gas pressure and collision cross-section. In many real-world spectra, such as those from stellar atmospheres or laboratory plasmas, the observed profile is a Voigt function, the convolution of Gaussian (Doppler and instrumental) and Lorentzian (natural and pressure) components. The FWHM of the Voigt profile, \Delta \nu_V, can be approximated for cases where one component dominates or when widths are comparable as \Delta \nu_V \approx \sqrt{(\Delta \nu_G)^2 + (\Delta \nu_L)^2}, where \Delta \nu_G and \Delta \nu_L are the Gaussian and Lorentzian FWHMs, respectively; more precise calculations often require numerical methods. This composite broadening complicates direct interpretation, necessitating profile fitting to disentangle contributions. Measuring intrinsic FWHM requires accounting for instrumental , which convolves with the sample's true and sets a lower limit on observable widths (typically 0.1–1 nm for common spectrometers). techniques, such as least-squares fitting or methods, are employed to extract the sample's broadening from the measured , enabling accurate determination of physical parameters like or . For instance, in , high-resolution instruments achieve FWHMs below 0.01 nm, allowing separation of isotopic shifts. A key application is in analyzing atomic spectra, where narrow FWHMs indicate long-lived excited states; for example, visible transitions in atoms like sodium exhibit natural linewidths corresponding to lifetimes around $10^{-8} s, yielding FWHMs of about 10 MHz. Broader lines, such as those in molecular spectra under , can reach GHz widths, reflecting collisional . These measurements underpin fields like and precision metrology.

Signal processing

In , the full width at half maximum (FWHM) characterizes the temporal extent of and the spectral breadth of waveforms, providing a robust measure for transient signals in applications such as communications and systems. For Gaussian pulses, which approximate many ideal waveforms in RF and optical domains, the FWHM pulse duration \tau_\text{FWHM} relates to the frequency bandwidth \Delta \nu_\text{FWHM} through the time-bandwidth product \tau_\text{FWHM} \Delta \nu_\text{FWHM} = 0.441 for transform-limited cases, establishing a fundamental limit on how narrow a pulse can be in both time and frequency. This relation, derived from properties, enables engineers to predict signal or based on . In the context of filters and system responses, FWHM quantifies by defining the range where the power exceeds half its peak value, often aligning with the conventional 3 cutoff for bandpass designs. For instance, resonant filters exhibiting a lineshape use FWHM to denote the decay-limited , influencing selectivity in analog and circuits. Chirped pulses, where frequency varies linearly across the duration due to dispersion, introduce asymmetry that alters the effective FWHM relative to unchirped profiles. In such cases, the intensity autocorrelation trace shows characteristic sidelobes or uneven wings, causing the autocorrelation FWHM to overestimate the true pulse duration by factors depending on chirp rate, necessitating advanced retrieval methods for accurate characterization. A practical example occurs in ultrafast laser systems for signal generation, where sub-picosecond FWHM values signify ultrashort pulses suitable for high-speed applications; mode-locked Ti:sapphire lasers, for instance, routinely achieve ~70 fs FWHM durations, enabling terahertz-rate sampling in photonic signal processing.

Imaging and resolution

In optical systems, the full width at half maximum (FWHM) of the () serves as a key metric for assessing , quantifying the extent to which a is blurred into a finite-sized image. The represents the response of the imaging system to an ideal delta function input, and its FWHM directly indicates the smallest resolvable feature size, as features smaller than this width become indistinguishable due to diffraction-limited blurring. For instance, in diffraction-limited systems with a circular aperture, the takes the form of an , where the FWHM is approximately 0.51 λ / , with λ denoting the wavelength of light and the numerical aperture of the objective. This measure is preferred over the Rayleigh criterion in many practical contexts because it provides a more direct gauge of the intensity profile's width at half maximum, enabling precise comparisons across instruments. In , the FWHM of the exhibits distinct differences between lateral and axial directions, reflecting the anisotropic nature of the illumination and detection geometry. Laterally, the FWHM typically achieves resolutions around 180–200 nm for visible wavelengths and high-NA objectives (e.g., NA = 1.4), benefiting from the pinhole's rejection of out-of-focus light to sharpen the in-plane response. Axially, however, the FWHM is poorer, often reaching 500 nm or more, due to the elongated along the caused by the finite and mismatches in specimens. These disparities limit volumetric imaging capabilities, prompting techniques like two-photon excitation to improve axial performance while maintaining lateral sharpness. Deconvolution algorithms leverage the measured FWHM of the to distinguish instrumental blur from the intrinsic size of imaged features, enhancing beyond the limit in post-processing. By modeling the observed image as the of the true object with the known —whose FWHM is experimentally determined or simulated— reverses this blurring effect, effectively narrowing the apparent feature widths. For example, if the measured FWHM of a sub-resolution particle exceeds the 's FWHM, the excess can be attributed to the particle's true size, allowing quantitative separation through iterative fitting or filtering. This approach is particularly valuable in fluorescence microscopy, where it restores contrast in densely labeled samples without additional hardware. Astronomical imaging exemplifies FWHM's role in large-scale applications, as seen with the (), where the 's FWHM for point sources like stars measures approximately 0.05 arcseconds in high-resolution channels such as the High Resolution Channel (HRC) of the Advanced Camera for Surveys (ACS). This fine PSF enables the resolution of fine details in distant galaxies and transits, with the FWHM varying slightly across of view due to optical aberrations but remaining diffraction-limited at visible wavelengths. In modalities like , similar FWHM-based PSF characterization supports blur correction for subsurface tissue visualization.

Estimation Methods

Analytical approaches

Analytical approaches to computing the full width at half maximum (FWHM) for well-known functional forms typically involve direct algebraic solving of the equation f(x) = f_{\max}/2 to find the points where the function reaches half its peak value, with the difference between those points yielding the width. For parameterized functions that are near the peak, such as those exhibiting small asymmetries, a parabolic approximation can be applied by fitting f(x) \approx h - a (x - \mu)^2 around the maximum, leading to an exact solution for the half-width d = \sqrt{h / (2a)} and thus FWHM = $2d = \sqrt{2h / a}. This method is particularly useful for rough estimates in when the peak curvature is well-captured by a second-order expansion, assuming deviations from symmetry are minor. For more complex profiles like the Voigt function, which lacks a for FWHM due to its nature as a of Gaussian and components, empirical approximations provide efficient computation. A widely used formula, accurate to within 0.02% relative error across all ratios of component widths, is given by Olivero and Longbothum as
\text{FWHM}_V \approx 0.5346 \, \text{FWHM}_L + \sqrt{0.2166 \, \text{FWHM}_L^2 + \text{FWHM}_G^2},
where \text{FWHM}_L and \text{FWHM}_G are the full widths at half maximum of the and Gaussian components, respectively. This approximation is exact in the limits of pure (\text{FWHM}_G = 0, where \text{FWHM}_V = \text{FWHM}_L) and pure Gaussian (\text{FWHM}_L = 0, where \text{FWHM}_V = \text{FWHM}_G), with maximum errors occurring at intermediate mixing ratios but remaining below 0.02% for dominance (when \text{FWHM}_G \ll \text{FWHM}_L).
Symbolic computation software, such as , enables exact analytical solutions for FWHM in cases where the functional form permits symbolic root-finding, like or higher-order polynomials, by leveraging algorithms to solve transcendental equations when possible.

Numerical and experimental techniques

In numerical estimation of the full width at half maximum (FWHM) from experimental data, interpolation methods offer practical approaches to refine measurements beyond raw point sampling. estimates the FWHM by connecting the two nearest data points above and below the half-maximum intensity with a straight line and solving for the intersection widths. , using cubic or higher-order polynomials fitted piecewise across the peak, provides a smoother , reducing errors in irregularly sampled or noisy datasets; this local method has been shown to yield more accurate results than global fits in profiles. These techniques are essential in fields like nuclear imaging, where pixel resolution limits direct measurement precision. Recent comparative studies have evaluated multiple methods for FWHM estimation, including direct measurement and those based on standard deviation approximations, highlighting their performance in various contexts. Fitting algorithms enable robust FWHM determination by modeling the shape against theoretical profiles. Least-squares optimization fits Gaussian or functions to the data, iteratively adjusting parameters such as , , and width to minimize residuals; for , nonlinear variants like the Levenberg-Marquardt efficiently handle the asymmetric form. The χ² minimization serves as a statistical measure of fit quality, incorporating data uncertainties to weight points and avoid , particularly useful in low-signal regimes. In applications, such fittings often outperform simple by accounting for underlying physical broadening mechanisms. Experimental techniques for reliable FWHM measurement address common data artifacts. Noise reduction via averaging multiple spectral acquisitions enhances the signal-to-noise ratio, enabling clearer half-maximum identification without introducing bias. Baseline subtraction corrects for instrumental drifts or backgrounds by fitting low-order polynomials to off-peak regions or employing asymmetric least-squares algorithms that preserve peak integrity while suppressing trends. For peak isolation in Fourier-domain data, apodization with window functions like Hamming or Blackman reduces Gibbs ringing artifacts, though it trades some resolution for sidelobe suppression. Voigt profile fitting may be referenced briefly in spectroscopic contexts to convolve Gaussian and Lorentzian components for hybrid line shapes. Uncertainty in FWHM estimates arises from noise, sampling, and model assumptions, necessitating resampling methods for quantification. Bootstrap techniques generate pseudo-datasets by resampling with replacement from the original measurements, computing FWHM repeatedly to derive intervals via the standard deviation of the distribution. approaches simulate noise addition based on measured variances, propagating errors through the estimation process to yield probabilistic , such as those on the order of 5-10% of the FWHM value in typical spectroscopic setups. These methods provide empirical validation of precision without assuming parametric distributions.

References

  1. [1]
    Full Width at Half Maximum -- from Wolfram MathWorld
    The full width at half maximum (FWHM) is the distance between points on a curve where the function reaches half its maximum value.Missing: definition | Show results with:definition
  2. [2]
    Gaussian — Nevis Labs ROOT tutorial May-2025 documentation
    σ = the standard deviation; it's related to the “full width at half maximum” (FWHM) of the curve by FWHM = 2 σ 2 ln ⁡ 2 ≈ 2.35 σ .
  3. [3]
    Spectral Resolution | NIST
    Jan 15, 2025 · measure of the ability to distinguish between adjacent peaks in a spectrum; it is usually determined by measuring peak width at half the ...Missing: definition | Show results with:definition
  4. [4]
    Lifetime and Line Width
    This gives the energy distribution of an unstable state. It is called the Breit-Wigner line shape. It can be characterized by its Full Width at Half Maximum ( ...
  5. [5]
    ALMA Basics — ALMA Science Portal at NRAO
    The full-width-at-half-maximum (FWHM) of the primary beam is usually taken as the diameter of the field of view of an interferometer; however, note that the ...Missing: definition | Show results with:definition
  6. [6]
    Terminology and concepts for the characterization of in vivo MR ...
    A proxy for spectral resolution is the resonance linewidth, which is commonly defined as the full width at half maximum (FWHM) of a singlet resonance measured ...
  7. [7]
    Comparison among methods for calculating FWHM - ADS
    Five methods for calculating full width at half maximum (FWHM) are presented and applied to computer generated pseudorandom normal distributions of known ...
  8. [8]
    Full width at half maximum – Knowledge and References
    Full width at half maximum (FWHM) is the width of a structure at half its maximum value, measured by the distance between points at half the maximum intensity.
  9. [9]
    Atomic Spectroscopy - Spectral Line Shapes, etc. | NIST
    Oct 3, 2016 · For a Maxwellian velocity distribution, the line shape is Gaussian; the full width at half maximum intensity (FWHM) is, in Å,. ΔλD1/2=(7.16 ...
  10. [10]
    Methods for estimating full width at half maximum
    Feb 13, 2025 · Full width at half maximum (FWHM) is a measurement for characterizing the width of a peak of any curve resembling a Gaussian one. It is commonly ...
  11. [11]
    The Gaussian or Normal Distribution
    In some applications, however, the full width at half maximum (FWHM) is often used instead. This is somewhat larger than sigma and can easily be shown to be.Missing: definition | Show results with:definition
  12. [12]
    What is Full Width at Half Maximum (FWHM)? - StellarNet, Inc.
    Apr 21, 2017 · The full width at half maximum (FWHM) is the width of a line shape at half of its maximum amplitude, as shown below.
  13. [13]
    Bandpass and Resolution - HORIBA
    The bandpass is then defined as the Full Width at Half Maximum (FWHM) of the trace, assuming monochromatic light. Any spectral structure may be considered to be ...
  14. [14]
    Mass Resolution and Resolving Power - Fiehn Lab
    Older publications around 1920-1940 ... A specific m/z value and also the method like 10% valley or 50% valley or full width at half maximum (FWHM) must be given.
  15. [15]
    full width half maximum | Photonics Dictionary
    The full width at half maximum (FWHM) is a measure used in various fields, particularly in spectroscopy, signal processing, and imaging, to characterize the ...
  16. [16]
    [PDF] MATHEMATICS - Oregon State University
    With x0 gone, the frequency ω and oscil- lation period T = 2π/ω are independent of amplitude. ... FWHM for another decaying function. Use the FWHM heuristic to ...
  17. [17]
    Instrumental function of the SPECS XPS system - ScienceDirect.com
    Consequently, the instrumental function of this XPS system should also be a Gaussian with FWHM wXPS equal to the square root of the sum of squares of the ...
  18. [18]
  19. [19]
    Atomic Spectros. - Spectral Line Shapes, etc. - NIST
    ... full width at half maximum intensity (FWHM) is, in ,. $\Delta\lambda_{1/2}^D = (7.16\, (40). T is the temperature of the emitters in K, and M the atomic weight ...
  20. [20]
    Full width at half maximum | The Book of Statistical Proofs
    Aug 19, 2020 · ... Full width at half maximum. Definition: Let X X be a continuous random variable with a unimodal probability density function fX(x) f X ( x ) ...
  21. [21]
    fwhm - k-Wave
    fwhm calculates the Full Width at Half Maximum (FWHM) of a positive 1D input function f(x) with spacing given by x. For example, running the code x = -pi/2 ...
  22. [22]
    [PDF] Basic Concepts
    Oct 30, 2019 · • Cosine function f(x) = cos(x) ... Arbitrary peaked signals are often characterized by the full width at half maximum (FWHM), which is the.<|control11|><|separator|>
  23. [23]
    Proof: Full width at half maximum for the normal distribution
    Aug 19, 2020 · Proof: Full width at half maximum for the normal distribution ... Theorem: Let X X be a random variable following a normal distribution: X∼N(μ,σ2) ...
  24. [24]
    Lorentzian Function -- from Wolfram MathWorld
    The Lorentzian function is the singly peaked function given by L(x)=1/pi(1/2Gamma)/((x-x_0)^2+(1/2Gamma)^2), where x_0 is the center and Gamma is a parameter ...
  25. [25]
    [PDF] 1 CHAPTER 11 CURVE OF GROWTH 11.1 Introduction The curve of ...
    The curve of growth is a graph showing how the equivalent width of an absorption line, or the radiance of an emission line, increases with the number of atoms ...
  26. [26]
    1.3.6.4. Location and Scale Parameters
    A probability distribution is characterized by location and scale parameters. Location and scale parameters are typically used in modeling applications. For ...
  27. [27]
    1.3.6.6.1. Normal Distribution - Information Technology Laboratory
    Normal Distribution. Probability Density Function, The general formula for the probability density function of the normal distribution is.
  28. [28]
    Halfwidth of a Gaussian Distribution - HyperPhysics
    The full width of the gaussian curve at half the maximum may be obtained from the function as follows. Let x=h at half the maximum height. Taking the natural ...
  29. [29]
    3.3.3 Cauchy Distribution - MIT
    This is the Cauchy probability density function. It possesses the interesting property that its variance is infinite (since the integral tends to L as L ...Missing: source | Show results with:source
  30. [30]
    [PDF] Absorption Features - NMSU Astronomy
    The half–width at half–maximum, fwhm/2, is also equal to y. x0)/2y. The function has unity area, so that the amplitude at the peak is 1/πy when the full width ...
  31. [31]
    [PDF] Where from Lorentzian?
    Oct 11, 2017 · The Lorentzian derives from the equation of motion for the displacement x of a mass m ... (FWHM) equal to 2|ν0 − ν| = Γ.
  32. [32]
    8. The Energy-Time Uncertainty Principle: Decaying States and ...
    This distribution (called Lorentzian) ... This energy spread of the resonance is the Γ above, and is related to the “lifetime” of the resonance by Δ E⋅Δ t≥ℏ.
  33. [33]
    [PDF] MASSACHUSETTS INSTITUTE OF TECHNOLOGY - MIT
    From the Uncertainty Principle we know: ∆E ∆t ≥ h/2, for a wavepacket, which translates to: Γ τ ≥ h for a resonant line width Γ (FWHM) and lifetime τ.
  34. [34]
    [PDF] UFS Lecture 3: Optical Pulses and Dispersion
    Both are measured at full-width at half- maximum (FWHM). Uncertainty principle: Kt. ≥∆∆ ν. Time Bandwidth Product (TBP). A number depending only on pulse shape.
  35. [35]
    [PDF] 50 GHz detector impulse response measurement using a sampling ...
    We determine the frequency response of high-speed photoreceivers from time-domain measurements collected with a 50 GHz sampling oscilloscope. In order to obtain ...
  36. [36]
    Precision in peak parameter estimation for Gaussian and Lorentzian ...
    The Lorentzian profile is defined as a function of I , ω c , and the full width at half maximum (Γ) by the following equation: γ ( ω i ; θ ̂ ) = I 1 + 4 ω i − ω ...
  37. [37]
    [PDF] Ultrafast operation of a mode-locked Ti:sapphire laser
    We calculate the FWHM pulse width to be about 270 fs, compared to the initial pulse width of about 70 fs. 4. Conclusions. We characterize a work-in-progress Ti: ...
  38. [38]
    Microscope Resolution: Concepts, Factors and Calculation
    As already mentioned, the FWHM can be measured directly from the PSF or calculated using: RFWHM = 0.51λ/(NA). Again using a light wavelength of 514 nm and an ...
  39. [39]
    Microscopy Basics | The Point Spread Function - Zeiss Campus
    The full-width at half maximum (FWHM) is indicated for the lower NA objective along with the Rayleigh limit.
  40. [40]
    Improving Axial Resolution in Confocal Microscopy with New High ...
    Mar 30, 2015 · When optimally used, confocal microscopes may reach resolutions of 180 nm laterally and 500 nm axially, however, axial resolution in depth is ...
  41. [41]
    Deconvolution
    Deconvolution corrects the systematic error of blur (loss of contrast in smaller features) in optical systems such as fluorescence microscopy images.Missing: FWHM | Show results with:FWHM
  42. [42]
    [PDF] A Practical Guide of Deconvolution - ZEISS
    The PSF describes the measure of blur in a given imaging system . An optimal PSF is key to improving the quality of the image as a result of the deconvolution.
  43. [43]
    5.6 ACS Point Spread Functions - HST User Documentation - HDox
    The HRC FWHM is 0.060 to 0.073 arcseconds in F550M. More details on ACS PSF field variations are provided in ACS ISR 2003-06. The Tiny Tim PSF simulator ...
  44. [44]
    Airy Disk - an overview | ScienceDirect Topics
    Resolution is sometimes expressed in terms of the full width at half maximum (FWHM) of the image of a point object, which is 3.232 in optical coordinates.
  45. [45]
    Analytical and experimental FWHM of a gamma camera - NIH
    Three mathematical methods (direct calculation, global interpolation using gaussian and local interpolation using splines) for calculating FWHM from a line ...
  46. [46]
    [PDF] 1 Nonlinear Least Squares: Fitting a Lorentz Profile to Data.
    Gauss-Newton method. To evaluate this expression for the Lorenntzian profile, we will need the partial derivatives of L with respect to x0,h and w: ∂L. ∂x0.
  47. [47]
    Preprocessing, analysis and quantification in single-voxel magnetic ...
    Common apodization functions include an exponential or Gaussian decay. Although apodization reduces noise and generally improves SNR, it also has some unwanted ...
  48. [48]
    A practical approach for determination of mass spectral baselines
    In theory, the baseline drift of a single spectral peak acquired in the profile mode can be corrected by deduction of the lowest intensity of its data points.
  49. [49]
    Uncertainty in relative energy resolution measurements
    The standard deviation of relative energy resolutions calculated for each “pseudo-experimental” data set (bootstrap uncertainty) is considered to be an estimate ...