Pelletron

A Pelletron is an that generates high voltages using a moving chain composed of metal pellets connected by insulating links, rather than a traditional rubber belt, to transport charge to a central high-voltage . This design enables the acceleration of beams, either in a single-ended configuration for positive ions or a setup where negative ions are injected, stripped of electrons, and accelerated as positive ions to achieve higher energies. Pelletrons typically operate within a pressurized filled with insulating gas, such as SF6, to support terminal voltages ranging from several megavolts up to 30 MV or more, producing beams for applications in , , and . The Pelletron was developed in the mid-1960s by Raymond G. Herb and his collaborators at the in the United States, evolving from earlier Van de Graaff generators to address limitations like belt wear and instability. Initial prototypes demonstrated improved charge transport through the use of steel pellets charged by , allowing for smoother discharge at the terminal and bidirectional charging chains that double the current capacity to 100–300 μA. By the 1970s, had refined the system, incorporating advanced materials and designs, leading to commercial installations worldwide; for instance, a 14 MV Pelletron was installed at the (TIFR) in , , in December 1988, with beam experiments commencing in mid-1989. Key features of the Pelletron include its exceptional voltage stability—maintaining fluctuations below 1 kV—and a chain lifetime exceeding 50,000 hours without producing contaminating dust, unlike belt-based systems. The accelerator supports a wide range of ion species, from protons to heavy ions like uranium, with final beam energies depending on the configuration; tandem models can deliver beams up to 200 MeV for lighter ions, often integrated with additional boosters like linear accelerators for higher energies. Control systems, such as NEC's AccelNET software, enable precise beam tuning, pulsing (with widths as short as 1–2 ns), and distribution to multiple experimental beamlines via switching magnets. Pelletrons have become the preferred choice for low- to medium-energy due to their reliability and ease of maintenance, powering research at facilities like the Inter-University Accelerator Centre (IUAC) in , where a 15 UD model has operated since July 1991, serving over 400 users in diverse fields. Ongoing advancements, including upgraded sources and voltage grading resistors, continue to enhance performance, ensuring the Pelletron's role as a of electrostatic .

History

Invention

The Pelletron, an electrostatic accelerator, was invented by Raymond George Herb in the mid-1960s while he was a at the of Wisconsin-Madison, where he sought to overcome the reliability limitations of belt-based charging systems in traditional Van de Graaff generators, such as material degradation and inconsistent charge transport. Herb's innovation centered on replacing the continuous rubber or canvas belts with a discrete chain of metal pellets linked by insulating material, which provided greater durability and stable voltage generation for high-energy particle acceleration. This design evolution addressed key shortcomings of earlier electrostatic machines by enabling more efficient charge transfer in pressurized environments. Initial prototype development occurred around , with and his collaborators testing the pellet chain system to ensure it could sustain high voltages without the sparking and wear issues plaguing belt chargers. The prototype demonstrated improved dependability, as the rigid, symmetrical metal pellets—typically made of aluminum or —facilitated precise induction charging and minimized mechanical failures. named the device "Pelletron" to reflect the use of these pellets in the charging mechanism. To commercialize the technology, Herb co-founded the National Electrostatics Corporation (NEC) in , in 1965 alongside J. A. Ferry and T. Pauly, focusing on producing reliable accelerators for research. Early protection included a key U.S. filed in June 1966 by Herb and Ferry, which detailed the pellet chain conveyor for high-voltage electrostatic generators (issued September 23, 1969, as US 3,469,118). Herb also documented the discrete pellet concept in technical papers, such as his contributions to nuclear instrumentation literature in the late and early , laying the groundwork for widespread adoption.

Development and Adoption

Following its invention, the development of the Pelletron accelerator advanced rapidly through commercialization efforts led by the , founded in 1965 by Raymond Herb, J.A. Ferry, and T. Pauly to manufacture these devices as an improvement over traditional Van de Graaff accelerators. focused on refining the charging chain and associated components, producing the first commercial units in the late ; a notable milestone was the 1968 order for an 8 MV tandem Pelletron installed in , marking the initial large-scale deployment. This expansion positioned as the primary producer, with over 230 systems eventually supplied worldwide by the 2020s. Voltage capabilities progressed significantly in the ensuing decades, starting with initial models in the rated at 1-3 MV, such as the 5U Pelletron installed at the around that time for materials analysis. A key enabler was the introduction of SF6 gas enclosures in the , which provided superior for insulating high-voltage components and suppressing electrical breakdowns, allowing safer operation at elevated potentials. By the , these innovations supported much larger systems, exemplified by the 25 MV 25URC tandem Pelletron at Oak Ridge National Laboratory's Holifield Heavy Ion Research Facility, operational since 1982 and representing the highest voltage achieved in electrostatic accelerators at the time. Adoption of Pelletron technology spread to research facilities in the and during the and , replacing or upgrading older Van de Graaff systems for , analysis, and . Early examples include the 14UD Pelletron commissioned in 1973 at a heavy and the installation at in in the early for nuclear structure studies. In the , national labs like Oak Ridge integrated higher-voltage models for advanced heavy-ion research, while universities such as the began leveraging smaller systems for applications in the late , fostering broader use in interdisciplinary experiments. These installations highlighted the Pelletron's reliability and scalability, driving its prevalence in over 50 countries by the late .

Design

Charging System

The charging system of a Pelletron accelerator employs a specialized chain composed of conductive metal pellets connected by insulating links, forming an endless loop that circulates between the ground potential and the high-voltage terminal. These pellets, typically aluminum cylinders, serve as the charge carriers, while the links—made of durable insulating —prevent electrical conduction between adjacent pellets and ensure mechanical flexibility. The 's design allows for reliable charge transport without the wear issues associated with belt-based systems, with proven operational lifetimes exceeding 50,000 hours in many installations. The pellets are engineered as solid cylindrical conductors to optimize charge retention and minimize mass, though specific surface treatments for leakage prevention are integrated during to enhance performance under high-voltage conditions. Systems may incorporate one to eight such chains, depending on the required charging current, which typically ranges from 100 to 300 μA per chain. The overall chain forms a closed loop tailored to the accelerator's dimensions, spanning the vertical height of the and supported by linear bearing frames with counterweights to maintain tension. Drive mechanisms consist of motorized pulleys at both the grounded and the high-voltage , with diameters generally between 30 and 60 cm, propelling at nominal speeds of approximately 18.5 m/s. These pulleys, often referred to as sheaves, guide smoothly, and the motors are counterbalanced to reduce vibrations and ensure stable operation. Charge addition and removal occur at dedicated up-charging and down-charging stations via an process, avoiding direct contact to prevent wear. At the up-charging station, a negatively biased generates an across the grounded drive , inducing positive charge on the pellets as they pass without any physical charge transfer from the . The down-charging station operates similarly but with reversed polarities on the and suppressor s, effectively doubling the chain's charging capacity by removing negative charge on the return path. This -based method relies on electrostatic influence rather than or contact brushes, providing cleaner and more stable charge handling. Through this transport, the charging system delivers electrons or ions to the high-voltage terminal to build and maintain the accelerator's potential.

High-Voltage Terminal and Tank

The high-voltage terminal in a Pelletron accelerator is positioned at the midpoint of the charging chain, serving as the central electrode where charge is accumulated to generate the electrostatic potential. This terminal is typically designed as a spherical or cylindrical conductor to minimize field gradients and ensure uniform voltage distribution, capable of supporting terminal potentials up to 25 MV or higher in large systems. In single-ended configurations, the terminal houses the ion source for positive ion acceleration, while in tandem setups, it accommodates the stripper foil for charge exchange, with the low-energy ion source located externally at ground potential. The terminal integrates with the charging chain to maintain stable voltage, enabling reliable operation across a range of accelerator types. The enclosing tank functions as a high-pressure vessel that provides the insulating environment necessary for sustaining the elevated voltages. Constructed primarily from to meet ASME and international pressure codes, with internal support structures incorporating aluminum elements for the accelerator column, the tank is filled with (SF6) gas at pressures ranging from 5 to 15 atm (typically around 80 psig or 5.5 atm, up to 10 bar in some mixtures with ) to achieve superior to air. Dimensions of the tank scale directly with the required terminal voltage and accelerator configuration; for instance, small single-ended units may feature compact tanks under 1 m in length suitable for benchtop or laboratory-scale applications up to 1 , whereas large systems can reach 10-20 m in length or height, often requiring multi-story buildings for installation. The SF6 recirculation system within the tank ensures gas purity and prevents contamination, contributing to long-term voltage stability. Safety features are integral to the terminal and tank design to mitigate risks associated with high voltages and pressurized gases. Comprehensive interlock systems monitor tank pressure, vacuum levels, and , automatically shutting down operations if thresholds are exceeded, such as insufficient SF6 pressure or unauthorized access. Pressure monitoring devices, including transducers and alarms, provide real-time oversight of the insulating gas, while grounding systems—such as automatic grounding bars and protective wiring—ensure safe discharge during maintenance by connecting all components to a ground. These measures protect personnel and equipment, with remote actuators and door interlocks further enhancing operational security in larger installations.

Acceleration Components

Pelletron accelerators are commonly used in tandem configurations, where an produces negative ions that are accelerated toward the high-voltage . At the , a stripper foil removes electrons, converting the ions to positive charge states, after which a post-accelerator provides additional energy gain as the positive ions are repelled from the . In single-ended configurations, positive ions are generated directly in the and accelerated to ground potential. Key components along the beam path include electrostatic lenses for focusing low-energy s in the and sections, magnets—often magnetic for high-energy post-acceleration beams—to maintain beam collimation, and Faraday cups for precise measurement of currents. Electrostatic lenses are particularly suited for low-power applications within the structure. The , located at the high-voltage in setups, consists of thin carbon films with thicknesses typically ranging from 2 to 20 μg/cm², optimized to efficiently remove electrons from incoming negative ions while minimizing beam and degradation. Voltage gradients in the Pelletron are achieved through uniform along the acceleration tubes, featuring gaps spaced at approximately 1-2 cm to support stable up to 30 kV per .

Operation

Charge Transport Mechanism

The charge transport mechanism in a Pelletron accelerator relies on a continuous loop of conductive metal pellets, typically aluminum cylinders approximately 9.5 mm long connected by insulating links with a of about 16 mm, forming an endless chain that circulates between ground potential and the high-voltage terminal. This chain, driven by pulleys at both ends, moves at a nominal speed of around 18 m/s to efficiently carry charge without excessive mechanical wear or voltage instability. The pellets are charged through electrostatic induction rather than direct contact or corona discharge, ensuring reliable operation in high-pressure insulating gas environments. In the up-charging process, at the grounded drive pulley, a negatively biased inductor electrode (typically at -10 to -20 kV) is positioned adjacent to the pellets as they approach and contact the pulley. This creates a strong electric field that repels electrons from the conductive pellets toward the grounded pulley, leaving the pellets with a net positive charge on their upper surfaces. As each pellet moves away from the inductor and pulley, the increasing separation reduces the capacitance between the pellet and the ground, trapping the induced positive charge on the pellet due to the insulating links isolating it from subsequent grounded components. The positively charged pellets are then transported upward along the ascending chain to the high-voltage terminal, where the process delivers a net positive charging current of 100–200 µA per chain to build and maintain the terminal's positive potential. At the terminal pulley, a negatively biased suppressor electrode (similar polarity to the ground inductor) ensures controlled charge transfer: as pellets contact the terminal pulley, the electric field allows the trapped positive charge to flow smoothly onto the conductive terminal structure without sparking, facilitated by U-shaped inductor designs that balance charge distribution. On the descending return run, down-charging occurs analogously but with reversed polarities—a positively biased inductor at ground induces negative charge on the pellets, which transport it downward to neutralize excess positive charge leaking to ground via column resistors, thereby maintaining the potential difference and doubling the overall charging capacity. This bidirectional transport prevents charge imbalance and supports stable operation up to several MV. The process exploits variable s formed by the alternating proximity of pellets to the biased electrodes and grounded surfaces, where the charge Q on each pellet is proportional to the voltage difference and C (Q = C V), with the ensuring incremental voltage buildup as distance increases. Chain and are precisely controlled—the motor maintains consistent speed to regulate charge delivery rate, while counterweighted linear bearing frames apply uniform (up to several thousand kg without failure) to keep the chain taut, minimizing slippage and ensuring each pellet carries a consistent small charge, typically on the order of 10^{-7} C, for uniform transport. These controls are critical for low (better than 0.1%) and long chain life exceeding 50,000 hours.

Voltage Generation and Stability

The Pelletron accelerator generates high terminal voltages through a process of electrostatic charge accumulation facilitated by its unique charging chain system. The chain, composed of metal pellets connected by insulating links, is charged inductively at the grounded end, where positive charge is drawn onto the pellets via a . As the chain moves upward, it transports this charge to the central high-voltage terminal, effectively adding charge to the terminal's formed between the terminal and the surrounding grounded tank walls. This iterative charge transfer builds the potential difference gradually; for large systems, achieving voltages up to 25 typically requires several minutes, depending on the charging current (100–200 μA per chain) and the system's total . Voltage stability in the Pelletron is achieved through a combination of material properties, mechanical precision, and electronic controls. The insulating tank is filled with (SF₆) gas, which provides a high of approximately 88 kV/cm at standard pressures, enabling reliable insulation at elevated potentials without . Chain speed is regulated mechanically to minimize fluctuations in charge delivery, while feedback systems—such as terminal potential stabilizers—employ generating voltmeters, capacitive pickoff sensors, and controls to adjust the voltage dynamically. These mechanisms maintain stability to within ±0.01% (or 1 kV at 10 MV), far surpassing earlier electrostatic accelerators. Pelletron models are rated for terminal voltages ranging from 0.5 to over 30 , with currents typically limited to 1–100 μA to prevent overloading the charging system. Common operational challenges include sparking, which occurs when the exceeds SF₆ thresholds due to impurities or variations; this is mitigated by maintaining gas purity above 99.99% through continuous recirculation and , ensuring consistent performance and extending operational uptime.

Beam Acceleration Process

In a tandem Pelletron accelerator, the beam acceleration process begins with the generation and injection of negative ions from an , such as a sputter source, which are pre-accelerated to energies of 20-50 keV before entering the low-energy acceleration tube. These negatively charged ions are then electrostatically attracted toward the positively charged high-voltage terminal at the center of the , gaining equal to the terminal voltage V (in energy units, eV, where e is the ) during this first stage of acceleration; for example, in a 25 terminal, a proton would gain approximately 25 MeV. Upon reaching the terminal, the negative ions pass through a thin stripping foil or gas stripper, where multiple electrons are removed, converting them into positively charged ions with a charge state q (in units of e). This stripping process enables the second stage of acceleration, as the now-positive ions are repelled from the terminal and accelerated through the high-energy tube back toward ground potential, gaining an additional energy of qV. For protons, which typically achieve a charge state of q = 1 after stripping, this results in a total energy gain of approximately $2eV; in a 25 MV system, protons can thus reach up to 50 MeV. Heavy ions, such as carbon or nitrogen, often strip to higher charge states (e.g., q = 3-6), allowing for proportionally greater final energies; for instance, at 1.7 MV, ^{12}C^{6+} ions achieve 11.9 MeV, while in larger systems up to 14 MV, heavy ions can reach energies scaled by (n+1) where n is the post-stripping charge state. The overall final beam E after both stages is given by E = (1 + q)V, where the initial negative charge contributes 1 and the post-stripping charge q determines the second-stage gain (neglecting minor pre-acceleration effects). This equation highlights the efficiency of the tandem configuration, effectively doubling the for singly charged particles compared to single-stage accelerators. For protons (q=1), E \approx 2V; for heavy ions like (q=2), energies are $3V, as seen in 1.7 MV systems yielding 5.1 MeV for He^{2+}. Following re-acceleration, the high-energy is extracted from the high-energy tube and directed to experimental targets using magnetic lenses and analyzing magnets for focusing and energy selection, achieving final energies ranging from 1 MeV for light ions in small systems to over 900 MeV for heavy ions in high-voltage configurations (e.g., beams in 25 MV ). This extraction ensures beam quality suitable for applications like experiments.

Advantages and Variants

Improvements over Van de Graaff

The Pelletron accelerator represents a significant advancement in electrostatic accelerator technology, developed in the mid-1960s by Raymond G. Herb at the University of Wisconsin to address key limitations of the traditional belt-driven Van de Graaff generators prevalent in the 1950s and 1960s. These earlier systems, which relied on rubber or canvas belts to transport charge, suffered from mechanical wear, dust generation from belt degradation, and sensitivity to environmental factors like , leading to inconsistent performance and frequent downtimes. Herb's innovation, commercialized through the founding of National Electrostatics Corporation in 1965, introduced a charging chain composed of interconnected metal pellets, providing a more robust alternative that enhanced overall system reliability. A primary improvement lies in the enhanced reliability of the Pelletron's pellet chain, which operates dust-free and with minimal wear compared to , achieving operational lifetimes exceeding 50,000 hours and often lasting 5-7 years or more before replacement. This design eliminates the dust and particulate buildup that plagued belt systems, reducing stoppages and enabling sustained operation with voltage fluctuations as low as 0.1% or better in optimized setups. Consequently, Pelletrons offer superior uptime and durability, with some chains remaining functional for over 40 years, offering higher availability than typical belt-driven accelerators due to fewer mechanical failures. In terms of performance, the Pelletron supports substantially higher terminal voltages—proven up to 30 MV—and charging currents of 100-200 µA or more per chain, approximately 2-3 times greater than comparable Van de Graaff systems, thanks to the uniform charging achieved via on the conductive pellets. The chain's ability to operate at higher velocities without degradation ensures more consistent charge transfer and reduced leakage, resulting in exceptional voltage stability and efficiency that were unattainable with belts prone to uneven charging and slippage. Maintenance benefits further distinguish the Pelletron, as the modular pellet chain allows for straightforward replacement—often faster and less disruptive than fabricating and installing custom-sized belts for Van de Graaff systems—while requiring no complex electronic diagnostics. This simplicity lowers operational costs and downtime, and the design's insensitivity to moisture and sparks minimizes production and environmental contamination associated with belt discharges. Overall, these enhancements have made the Pelletron a preferred for Van de Graaff installations, extending their viability for high-precision applications. The Laddertron, developed by High Voltage Engineering Corporation, represents a significant of the Pelletron charging system, featuring two parallel chains of conductive pellets connected by insulating links and bridged by metal rungs to form a ladder-like structure, which enables a charge transport capacity approximately 2-4 times greater than a standard single Pelletron chain due to the increased surface area for charge retention. This design is particularly suited for ultra-high voltage applications, such as accelerators exceeding 30 terminal potential, where higher charging currents—up to 500 μA—are required to maintain stability and support intense beam operations. Pelletrons are available in both single-stage (single-ended) and configurations, with single-stage variants adapted for lower-energy applications ranging from 0.5 to 5 , often employed in compact systems like ion implanters that require reliable, moderate-voltage beams without the need for negative stripping. In contrast, Pelletrons utilize a central high-voltage terminal to accelerate s in two stages, doubling the effective energy for heavier s in settings. Modern enhancements to Pelletron systems include hybrid configurations that integrate radio-frequency (RF) linear accelerator boosters, such as superconducting linacs, to extend beam energies beyond the inherent limits of electrostatic generation, typically achieving post-acceleration gains of several MeV per for heavy ions. These hybrids combine the stable, DC voltage of the Pelletron with RF acceleration stages to enable higher-energy experiments while preserving beam quality. Notable examples include National Electrostatics Corporation's () 15UD model, a 15 MV tandem Pelletron designed for heavy-ion with a vertical and multi-chain charging for voltages up to 16 MV in practice. The smaller S-series Pelletrons, with terminal voltages under 5 MV, cater to industrial applications such as implantation and materials processing, featuring lightweight, horizontal designs for ease of integration.

Applications

Nuclear Physics Research

Pelletrons play a crucial role in heavy-ion experiments by accelerating ions such as carbon, oxygen, and to energies suitable for studying , , and reaction mechanisms. These accelerators provide stable, high-voltage beams that enable precise investigations into the of interactions at low to intermediate energies, often serving as injectors for larger facilities or standalone systems for targeted experiments. For instance, at the Inter-University Accelerator Centre (IUAC) in , the 15UD Pelletron delivers heavy-ion beams to probe fusion-fission processes and time scales in , with ongoing research as of 2025. Key facilities utilizing Pelletrons for nuclear physics include NSF-supported tandem laboratories, such as the Institute for Structure and Nuclear Astrophysics (ISNAP) at the University of Notre Dame, which employs 5 MV and 3 MV Pelletrons for low-energy nuclear astrophysics, driving experiments on light and heavy ion reactions relevant to cosmic element formation. These setups, part of broader networks like the Association for Research at University Nuclear Accelerators (ARUNA), facilitate collaborative research across U.S. institutions. Specific techniques enabled by Pelletrons include for mapping interaction potentials, Coulomb excitation to probe shapes and collectivity, and studies to identify excited states in compound nuclei. Beam currents typically reach up to 100 particle μA for lighter ions, allowing sufficient intensity for detecting rare events in scattering chambers. At facilities like the Australian National University () 14UD Pelletron, Coulomb excitation experiments have characterized transitional states in isotopes such as and . Since the 1970s, when Pelletrons first became operational, they have contributed foundational data on , including deformation patterns and effects through heavy-ion induced reactions. Additionally, Pelletrons support rare isotope beam production, as seen at Notre Dame's TwinSOL facility, where they accelerate primary beams to generate secondary radioactive ions for studies beyond stability lines.

Materials Analysis and Modification

Pelletron accelerators play a significant role in materials science by providing stable, high-energy ion beams for non-destructive analysis and targeted modification of materials. These systems, typically operating in the 0.5-10 MeV range, enable precise depth profiling and elemental composition studies without significantly altering the sample structure. In ion beam analysis (IBA), techniques such as Rutherford backscattering spectrometry (RBS) and particle-induced X-ray emission (PIXE) are commonly employed to investigate thin films, semiconductors, and environmental samples. RBS utilizes MeV-energy ions, often helium or protons, to probe the elemental composition and depth distribution in light matrices, achieving resolutions of 10-50 nm and depths up to 20 microns with 1-5% accuracy in stoichiometry measurements. For instance, at the University of Minnesota's Characterization Facility, a 1.7 MV Pelletron tandem accelerator performs RBS on magnetic films like Mn-Fe-Co-Ni to quantify impurity distributions and film thickness. PIXE complements RBS by detecting trace elements from sodium to uranium at sub-ppm levels through characteristic X-ray emission induced by 1-3 MeV proton beams. Laboratories such as the University of North Texas Ion Beam Laboratory use 3 MV NEC Pelletron systems for PIXE in microprobe configurations, mapping elemental distributions at cellular resolution, as in studies of rat brain neurons or environmental dust phases. Similarly, the 1.7 MV Pelletron at the Mohamad Roumié Accelerator Laboratory in Beirut applies PIXE and RBS for analyzing over 600 archaeological ceramics and atmospheric aerosols, providing multi-elemental insights into material composition. For materials modification, Pelletron-based introduces ions into substrates to alter electrical, chemical, or mechanical properties, particularly in and processing. In doping, ions like are accelerated to 1-5 MeV and implanted into lattices to create p-type regions for transistors and integrated circuits, enabling precise control over electrical conductivity. tandem accelerators support this at energies above 400 keV, with specialized high-temperature chambers up to 800°C for post-implantation annealing. This technique is vital for fabricating diodes and other microelectronic components, offering advantages in uniformity over methods. Beyond direct analysis and implantation, Pelletrons facilitate (AMS) for isotopic tracing in materials. AMS on Pelletron systems measures ultralow-abundance isotopes, such as the ¹⁴C/¹²C ratio below 3 × 10⁻¹⁶, enabling precise dating of organic materials in and . For example, the 14 MV Pelletron at the Australian National University supports ¹⁴C analysis for age determination with milligram sample sizes. In environmental applications, AMS traces contaminants; detection via 500 kV Pelletrons at National Labs monitors byproducts in water and air, as seen in post-Fukushima studies. Additionally, Pelletrons contribute to pharmaceutical isotope production by generating short-lived radioisotopes for . The 9SDH-2 Pelletron at the University of Wisconsin-Madison delivers 100 μA of 6 MeV protons to produce isotopes like ¹⁸F (411 MBq/μA yield) and ¹¹C (311 MBq/μA), supporting (PET) tracers. Industrially, Pelletron systems are deployed in chip fabrication for targeted doping and in for isotopic tracing, leveraging their reliability for 24/7 operation. These accelerators provide beams from 0.5-10 MeV, ensuring high throughput in surface engineering and pollutant source identification.

References

  1. [1]
    [PDF] Electrostatic accelerators
    Aug 5, 2009 · The Pelletron [5] charging chains (see Fig. 4) were developed by Herb and collaborators from National Electrostatics Corporation (NEC) in the ...
  2. [2]
    Accelerator System Overview - National Electrostatics Corp.
    Continuous research through the decades resulted in the creation of the most stable and reliable electrostatic accelerator system in use today: the Pelletron.
  3. [3]
    The Pelletron Accelerator and Associated Facilities
    The Pelletron Accelerator [1] was installed in December 1988 and experiments using the beam were started in the middle of 1989. The source for the charged ...
  4. [4]
    Pelletron Accelerator | Inter-University Accelerator Centre (IUAC)
    Oct 29, 2025 · The 15 UD Pelletron, designed by NEC, USA, is a tandem electrostatic accelerator capable of delivering ion beams of nearly all stable nuclei, ...<|control11|><|separator|>
  5. [5]
    RAYMOND GEORGE HERB | Biographical Memoirs: Volume 72
    Ray Herb is famous for the design and development of pressurized electrostatic accelerators, which were the most widely used tools for nuclear physics research.
  6. [6]
  7. [7]
  8. [8]
    Pelletron seeking partnerships : Revista Pesquisa Fapesp
    The Pelletron is an electrostatic accelerator, in which large amounts of energy produce a powerful electric field capable of propelling ionized (electrically ...Missing: paper | Show results with:paper
  9. [9]
    A Retrospective of the Career of Ray Herb - AIP Publishing
    Ray Herb's career in the development of electrostatic accelerators spans 65 years. He began in 1933 by pressurizing a Van de Graaff generator, for the first ...
  10. [10]
    Accelerators Around the World Archives - National Electrostatics Corp.
    NEC has provided over 230 accelerator systems, as well as other systems, components, and services, in over 50 countries around the world.
  11. [11]
    Characterising the Pelletron beam at the University of Melbourne
    The Pelletron is a vertical electrostatic accelerator, serving multiple beamlines by rotating about the central axis. Ions are produced at the top of a 7 m tank ...
  12. [12]
    Voltage Limitations of Electrostatic Accelerators
    The fortuitous observation of the dramatic effect of an electronegative gas by Herb has led to the general use of pure SF6, a mixture of SF6 and nitrogen, or ...
  13. [13]
    Electron cooling of high energy ion beams in RHIC and other facilities
    The highest voltage Pelletron built to date is the 25 MV 25URC Pelletron at the Holifield Heavy Ion Research Facility (Oak Ridge National Laboratory). ... 1987 ...
  14. [14]
    [PDF] the holifield heavy ion research facility1 - OSTI
    The facility operates two accelerators: an NEC pelletron tandem accelerator designed to operate at terminal potentials up to 25 MV and the Oak Ridge Isochronous.<|separator|>
  15. [15]
    Milestones:Heavy Ion Accelerator Facility, 1973
    Mar 19, 2025 · The 14UD was the first large accelerator constructed by the National Electrostatics Corporation (NEC). ... accelerator for the 14UD Pelletron.
  16. [16]
    [PDF] Development of Accelerator Mass Spectrometry at the Lund Pelletron
    This machine was installed in the beginning of the. 1970's. Some of the modi¢cations made so far for changing this originally nuclear structure facility to a ...<|separator|>
  17. [17]
    ORNL's landmark accelerator completes a swan song series of ...
    May 9, 2016 · Oak Ridge National Laboratory's 25-megavolt Tandem Electrostatic Accelerator received an opportunity for one last hurrah in a series of experiments that ended ...Missing: Pelletron 1987
  18. [18]
    UNT Ion Beam Laboratory (IBL) | University of North Texas
    ... Pelletron® and a 3 MV SDH2 tandem Pelletron® accelerator. The 200 kV ... The industrial interactions with the IBL, which were begun in the late 1970's, have ...
  19. [19]
    Pelletron Charging System - National Electrostatics Corp.
    The Pelletron charging chain used in NEC accelerators was developed in the mid 1960s. The purpose was to be an improvement over older Van de Graaff charging ...Missing: first commercial
  20. [20]
    [PDF] Mechanical vibrations in the Pelletron and their effect on the beam
    Hoops with a diameter equal to the outside diameter ... The two Pelletron chains consist of aluminum cylinders, pellets, connected by insulating plastic joints.
  21. [21]
    [PDF] The New Large Tandem Electrostatic Accelerators
    First successful acceleration of beam on this accelerator was accomplished in October of 1979. To date, demonstration tests with Cl and I ion beams have been ...<|separator|>
  22. [22]
    Acceleration Tubes - National Electrostatics Corp.
    These tubes have historic use for Pelletron accelerators ranging from below 1 MV to above 25 MV terminal potentials. All metal and ceramic using a unique ...Missing: maximum | Show results with:maximum
  23. [23]
    KEVION NEC Pelletron
    The system is designed so that ions are created and mass-selected at ~20 keV inside the high voltage terminal for improved mass resolution (~200 m/Δm). The ...
  24. [24]
    Pressure Vessel - National Electrostatics Corp.
    The Pelletron is pressurized with SF6 insulating gas and includes a recirculation system for the SF6. The size of the Pelletron is dependent on the terminal ...Missing: enclosures 1970s
  25. [25]
    [PDF] NEC-5SDH-Manual.pdf - Nuclear Data Program
    The National Electrostatics Corporation Model 5SDH Pelletron is a 1.7 MV tandem electrostatic ion accelerator. This system is designed to accelerate light ions ...
  26. [26]
    9 MV FN Pelletron Tandem Accelerator
    In order to keep the high voltage on the terminal the tank of the accelerator an insulating mixture of gases is used (10 bars of SF6 and Nitrogen mixture).
  27. [27]
    Pelletron - Wikipedia
    A Pelletron is a type of electrostatic generator, structurally similar to a Van de Graaff generator. Pelletrons have been built in many sizes, ...
  28. [28]
    [PDF] Progress of an accelerator mass spectrometry system on the ...
    We have upgraded the 12UD Pelletron tandem. LEBT, divided resister system, terminal stripper. The beam time for AMS research has increased to about 42% of the ...
  29. [29]
    [PDF] Complete pelletron systems for ion beam analysis
    A comprehensive interlock system is provided to protect both personnel and equipment. The Pelletron is protect- ed against overheating, insufficient tank ...Missing: features | Show results with:features
  30. [30]
    [PDF] RADIATION PROTECTION TRAINING AT BARC-TIFR PELLETRON ...
    At Pelletron, Scram Buttons are provided in the Beam Hall. Door Interlocks: This design safety feature prevents the accidental exposure to an individual ...<|separator|>
  31. [31]
    Tandem Accelerator - FSU Fox's Lab Wiki
    Sep 27, 2023 · All the interlocks up to and including the tank pressure switch will disable both the chain drives and power supplies, the remaining only ...
  32. [32]
    Ion Beam Lenses - National Electrostatics Corp.
    Magnetic quadrupole lenses are designed for high energy ion beams. They are typically used to focus the beam on post acceleration extended beamlines.
  33. [33]
    Optimum thickness of carbon stripper foils in tandem accelerator in ...
    ... Pelletron tandem accelerator for carbon stripper foils of 1.8–19.5 μg/cm2 thickness, at terminal voltages of 5 and 10 MV, and (b) lifetime of 2–15 μg/cm2 thick ...Missing: cm² | Show results with:cm²
  34. [34]
    None
    ### Summary of Pelletron Charge Transport and Related Details
  35. [35]
    [PDF] The Pelletron Accelerator
    In 1965, development work on charging methods, on bonding, on accelerating tube behavior and on vacuum techniques was undertaken at National. Electrostatics .
  36. [36]
    Terminal Potential Stabilizers - National Electrostatics Corp.
    Summary ; Stability ±0.01%. *With liner correction on Pelletron systems: ±0.02% stability. X · X ; Local or remote control of terminal potential, probe current, ...Missing: maximum ratings
  37. [37]
    [PDF] SF6 properties, and use in MV and HV switchgear - Studiecd.dk
    The dielectric strength of SF6 is about 2.5 times higher than that of air under the same conditions. The advantage of SF6 over nitrogen as a dielectric is ...
  38. [38]
    [PDF] Terminal Voltage Stabilization of Pelletron Tandem Accelerator
    The conventional corona regulator is used to correct for the large, low-frequency fluctuations in the terminal voltage that are characteristic of the pelletron ...<|control11|><|separator|>
  39. [39]
    [PDF] Pramod V. Bhagwat & S. Kailas Pelletron Accelerator Facility ...
    • Column voltage rating 15 MV. • Tube voltage rating. 14 MV. • Voltage stability. ± 2 kV. • Proton energy range. 8 to 28 MeV. • Heavy ion energy range 4(n+1) to.
  40. [40]
    [PDF] Operation of Pelletron tandem accelerator
    The Pelletron tandem accelerator (5SDH-2) provides ion beams accelerated by up to 1.7 MV for sample irra- diation, material analysis, and developments of ...Missing: large height dimensions
  41. [41]
    5 MV Tandem accelerator - Uppsala universitet
    Sep 19, 2025 · The 5 MV Tandem Pelletron accelerator is the largest accelerator at the Tandem Laboratory. It produces a wide spectrum of light and heavy ...
  42. [42]
    [PDF] Electrostatic Accelerators - ICTP
    Sulfur hexafluoride​​ (SF6) is an inorganic, colourless, odourless, non-flammable, non-toxic and an excellent electrical insulator. The high dielectric strength ...
  43. [43]
    Pelletron and van de graff generator | PPTX - Slideshare
    A Pelletron uses a chain of metal pellets and insulating connectors to generate a high voltage on its terminal, allowing for tandem acceleration of ions.
  44. [44]
    [PDF] Absorption Coefficient
    ... Laddertron, which looks like two parallel Pelletron chains with metal bars connecting the pellets of one chain to the adjacent pellets of the other chain.
  45. [45]
    [PDF] Laddertron developments - HAL
    Feb 4, 2008 · 2014 Recent developments in laddertrons at Daresbury are described. The latest version can transport up to 500 03BC A of charging current at ...<|control11|><|separator|>
  46. [46]
    [PDF] Accelerators for Heavy Ions (Invited paper)
    Higher energy, especially for very heavy ions, will be obtained with foil stripping. The maximum output energy depends on ion mass as shown in Fig. 1. The ...
  47. [47]
    Tandem vs. Single Ended - National Electrostatics Corp.
    Both S-series and U-series Pelletrons can either be single-ended or tandem. In both cases, ion beams (both positive and negative) are accelerated by an.Missing: sizes small benchtop large
  48. [48]
    [PDF] SUPERCONDUCTING LINAC BOOSTER TO NSC PELLETRON
    Nuclear physics users await higher energies and most materials science projects need heavier projectiles of higher energies. A superconducting linac booster has ...Missing: hybrid | Show results with:hybrid
  49. [49]
    [PDF] National Electrostatics Corp.
    National Electrostatics Corp. (NEC) is the world's leader in the manufacture ... The NEC Pelletron® accelerators utilize the world's most stable high voltage ...
  50. [50]
    Nuclear reaction and structure studies using experimental facilities ...
    Dec 19, 2022 · Such studies were attempted at IUAC using heavy ion beams from 15UD Pelletron accelerator by performing experiments in 1.5 m diameter ...
  51. [51]
    [PDF] BARC – TIFR Heavy Ion Accelerator Facility 2004
    Experiments at our laboratory have revealed time scales involved in the various steps of the nuclear dynamics of the fusion-fission process. Time scales are not ...<|separator|>
  52. [52]
    Facility // Institute for Structure and Nuclear Astrophysics // University ...
    The Pelletron tandem accelerator of the HV FN type is primarily used for the nuclear structure and astrophysics program, as a driver for the TwinSOL radioactive ...
  53. [53]
    [PDF] Development of the St. Andre ion beam analysis facility at notre dame
    Oct 2, 2019 · A refurbished 3 MV tandem Pelletron® accelerator has been installed in the University of Notre Dame's Nuclear. Science Laboratory for the ...
  54. [54]
    Coulomb Excitation of 7 Li - CSIRO Publishing
    Beams of 7Li3+ ions, with bombarding energies in the range 12'5-30 MeV and typical intensities of200 nA, were obtained from the ANU 14UD Pelletron accelerator.
  55. [55]
    Coulomb excitation of ^"124"Te: Emerging collectivity and persisting ...
    Aug 13, 2025 · Beams of 185.5 185.5 -MeV 58 {}^{\text{58}} Ni and 45 45 -MeV 16 {}^{\text{16}} O were delivered by the 14UD Pelletron accelerator [45] , with ...
  56. [56]
    PELLETRON PROGRESS REPORT - INIS-IAEA
    Jul 1, 1977 · The Pelletron accelerator with its r-f ion source proved to be an efficient generator of some heavy ion beams and a limited program of heavy ion ...
  57. [57]
    Techniques - National Electrostatics Corp.
    Ion Implantation​​ Single ended or tandem accelerators can be used for beam energies of over 400 keV. NEC offers both high temperature (800º C) and low ...Missing: maximum | Show results with:maximum
  58. [58]
    Ion Beam Analysis | College of Science and Engineering
    Particle induced X-ray emission (PIXE) primarily for Na and heavier elements; Ion channeling based crystallinity analysis for single crystal or epitaxial ...
  59. [59]
    [PDF] The latest development of the 1.7 MV tandem accelerator in Beirut
    ➢ Ion beam analysis laboratory based on Pelletron accelerator. ➢Installation in 1999 within an IAEA TC project. ➢ Performing PIXE, PIGE, RBS/EBS, ERD techniques.
  60. [60]
    3 Ion Implantation Applications in Nuclear Science, Space & More
    Feb 28, 2024 · Through a process called doping, ion implantation introduces dopant atoms into the crystal lattice of a semiconductor material. Dopants are ...
  61. [61]
    8 Elements That Can Be Measured with AMS
    Jan 11, 2024 · AMS is commonly used for radiocarbon dating, with a growing worldwide interest in studying these 8 elements that can be measured with AMS.
  62. [62]
    [PDF] 19 Isotope Production for Medical Applications
    The 9SDH-2 Pelletron was designed to provide 100 µA of 6 MeV protons or deuterons within a maximum. 10 mm diameter beam spot. The actual performance ...Missing: pharmaceutical | Show results with:pharmaceutical