Fact-checked by Grok 2 weeks ago

Quinhydrone electrode

The quinhydrone electrode is a redox-type used for the potentiometric measurement of in aqueous solutions, consisting of an inert conductor, typically a wire or foil, immersed in a test solution saturated with quinhydrone—a 1:1 equimolar of p-benzoquinone (Q) and (H₂Q). This setup establishes a reversible half-cell reaction involving proton consumption or production, making the electrode's potential directly responsive to activity. Developed by Danish chemist Emil Biilmann in 1921 as a practical alternative to the cumbersome hydrogen electrode, the quinhydrone quickly gained prominence for its simplicity and rapid response in pH determinations. Its operation relies on the Nernstian dependence of the on , governed by the redox equilibrium Q + 2H⁺ + 2e⁻ ⇌ H₂Q, where the activities of Q and H₂Q remain constant due to the saturated quinhydrone phase. At 25 °C, the potential varies as E = E⁰ – 0.059 (versus the ), with E⁰ ≈ +0.699 V, enabling accurate pH readings when paired with a suitable like the . This temperature-dependent standard potential is given by E⁰ = 0.718 – 0.00074 t V, where t is in °C. Historically applied in fields such as , dairy product analysis, and biological fluid measurements—including in vivo microelectrodes for renal tubules—the quinhydrone electrode offered reliable performance for nearly four decades before being largely supplanted by glass electrodes. It excels in dilute acidic solutions (pH < 8) due to the stability of the quinone-hydroquinone couple under low oxygen conditions, providing quick equilibration (often within seconds) and minimal liquid junction potentials in compatible systems. However, its utility is constrained in alkaline media (pH > 8.5), where deprotonates and the complex decomposes, as well as in solutions containing strong oxidants, reductants, proteins, or that interfere with the equilibrium or poison the surface. Despite these limitations, variants like collodion-membrane encapsulated designs have extended its niche applications in complex matrices.

Background

Definition and Overview

The quinhydrone electrode is a type of indicator electrode employed in potentiometric measurements, consisting of quinhydrone—a 1:1 addition complex of p-benzoquinone and hydroquinone—in contact with a platinum wire immersed in the test solution. This setup leverages the redox equilibrium between hydroquinone (H₂Q) and quinone (Q) to generate a potential responsive to the solution's hydrogen ion activity. The electrode's function relies on the hydroquinone-quinone redox couple, where the half-reaction Q + 2H⁺ + 2e⁻ ⇌ H₂Q establishes a potential that varies linearly with pH. In practice, quinhydrone is added to the solution, dissociating into equal activities of Q and H₂Q, which ensures a stable ratio and ties the electrode potential directly to [H⁺]. This makes it suitable for pH determination when paired with a reference electrode, offering a simpler alternative to the hydrogen electrode or the more common glass electrode in certain aqueous systems. The potential E of the quinhydrone electrode follows the for the two-electron process: E = E^\circ + \frac{[RT](/page/RT)}{F} \ln a_{\ce{H+}} + \frac{[RT](/page/RT)}{2F} \ln \frac{a_Q}{a_{\ce{H2Q}}} where E^\circ is the standard potential, [R](/page/RT) is the , T is the temperature in , F is the , and a denotes activity. With quinhydrone maintaining a_Q \approx a_{\ce{H2Q}}, the equation simplifies to E = E^\circ + \frac{[RT](/page/RT)}{F} \ln a_{\ce{H+}}, yielding a pH dependence of approximately -59 mV per pH unit at 25°C.

Historical Development

The properties of the quinone-hydroquinone couple were recognized in the late as part of broader investigations into organic systems, laying the theoretical groundwork for their application in electrochemical sensing. This conceptual foundation evolved into practical electrode designs in the early , driven by the need for reliable measurements without the complexities of gas evolution. The quinhydrone electrode was invented in 1921 by Danish chemist Einar Biilmann, who sought a straightforward alternative to the hydrogen electrode for routine determinations. Biilmann's motivation stemmed from the hydrogen electrode's requirement for hydrogen gas, which made it cumbersome and prone to inconsistencies in everyday laboratory use; the quinhydrone approach, by contrast, offered a non-gassy, rapid method based on the equilibrium between and . He detailed the electrode's construction and performance in a seminal paper published that year. Following its introduction, the quinhydrone electrode saw rapid early adoption throughout the and , with researchers applying it to diverse fields such as soil analysis, biological fluids, and . A notable milestone was its integration into commercial pH instrumentation, exemplified by Arnold O. Beckman's 1934 quinhydrone-based , developed specifically for acidity measurements in the citrus industry to assess fruit quality and processing needs. By the post-1950s era, the quinhydrone electrode's prominence waned as the gained favor for its superior versatility, stability across wider ranges, and lack of interference from the electrode's chemical additives. Despite this decline, the electrode persisted in niche applications where its simplicity remained advantageous, such as certain nonaqueous or specialized electrochemical setups.

Chemical Basis

Composition of Quinhydrone

Quinhydrone is a 1:1 with the molecular formula \ce{C12H10O4}, formed by p-benzoquinone (\ce{C6H4O2}) and (\ce{C6H6O2}). This equimolar adduct arises from the interaction between the oxidized quinone and reduced hydroquinone moieties, resulting in a stable crystalline structure suitable for electrochemical applications. The compound is typically prepared by dissolving equimolar quantities of p-benzoquinone and in a hot solvent such as or , followed by slow cooling to induce of dark green needles or plates. Alternative mechanochemical methods involve grinding the two components together without solvent, though solution-based approaches are more common for obtaining pure crystals. Quinhydrone exhibits low in , approximately 4 g/L at 20°C, which facilitates its isolation as a solid while allowing partial dissociation in aqueous media for use. Physically, quinhydrone appears as a dark green crystalline solid with a metallic luster when viewed in bulk, and it melts at 167–172°C. It remains stable under neutral to acidic conditions but decomposes in strong alkaline environments, where the hydroquinone component deprotonates, disrupting the complex. For reliable performance in redox electrodes, analytical-grade quinhydrone with purity exceeding 97% is essential, as impurities can shift the equilibrium potential and compromise measurement accuracy. High-purity starting materials, such as reagent-grade p-benzoquinone and hydroquinone, are recommended during synthesis to minimize contaminants like residual solvents or oxidation byproducts.

Redox Chemistry

In , quinhydrone dissociates into equimolar amounts of p-benzoquinone (Q) and (H2Q), as represented by the : \ce{Q \cdot H2Q ⇌ Q + H2Q} The for quinhydrone formation (the reverse reaction) is approximately $10^4, ensuring nearly equal concentrations of Q and H2Q in saturated solutions. The underlying chemistry involves the reversible : \ce{Q + 2H+ + 2e- ⇌ H2Q} with a standard reduction potential E^\circ \approx 0.699 V versus the standard hydrogen electrode (SHE) at 25°C. The electrode potential follows the Nernst equation for this two-electron, two-proton couple: E = E^\circ + \frac{RT}{2F} \ln \left( \frac{[Q][\ce{H+}]^2}{[H_2Q]} \right) Given the equal concentrations of Q and H2Q in saturated solutions, the equation simplifies to a direct dependence on pH: E = E^\circ - \frac{2.303 RT}{F} \mathrm{pH} At 25°C (RT/F \approx 0.0257 V), this yields a theoretical slope of -59 mV per pH unit, linking the potential thermodynamically to the hydrogen ion activity. The temperature coefficient of the electrode potential, dE/dT \approx -0.74 mV/K, arises from the thermodynamic properties of the redox equilibrium and must be considered for accurate measurements across temperature variations.

Operation

Electrode Construction

The quinhydrone electrode is constructed using an inert platinum conductor, typically a wire or foil with a surface area of approximately 1 cm², which serves as the sensing element. This platinum component is immersed directly into the test solution that has been saturated with quinhydrone, an equimolar complex of p-benzoquinone and hydroquinone. The saturation is achieved by adding excess quinhydrone powder, ensuring a 1:1 ratio of the redox pair remains in equilibrium with the solution, often in quantities of about 0.5–1.0 g per 100 mL to guarantee supersaturation with undissolved crystals present. Preparation begins with cleaning the platinum electrode to remove contaminants and ensure reproducible surface activity. The platinum is gently scrubbed with a mild surfactant, such as liquid soap or Micro-90, using a soft toothbrush to avoid scratching the surface, followed by thorough rinsing with deionized water. For more persistent impurities, the electrode may be soaked in a 10% nitric acid solution for 2–3 hours before final rinsing and drying. Quinhydrone is then introduced to the test solution by mixing equimolar amounts of p-benzoquinone and hydroquinone, or using pre-formed quinhydrone crystals, and stirring for 5–10 minutes to allow equilibration and saturation at room temperature. The cleaned platinum is immediately immersed in this saturated mixture, where it contacts both the solid quinhydrone and the solution, establishing the redox equilibrium. In a typical potentiometric cell configuration, the quinhydrone electrode is paired with a , such as a (SCE) or silver/silver chloride (Ag/AgCl) electrode, connected via a filled with saturated KCl to minimize junction potentials, though low-resistance setups may omit the bridge. The assembly is represented as Pt | Q, H₂Q || test solution | , allowing direct measurement of the potential difference without additional compartments. Equilibration of the system typically requires 5–10 minutes of gentle stirring to ensure uniform distribution of the quinhydrone. Variations in construction include microelectrodes for applications involving small sample volumes, such as biological fluids, where a miniaturized tip (e.g., needle-type) is coated or embedded with quinhydrone to maintain sensitivity in microliter-scale environments. Semimicro designs, often stored in a dry state until use, incorporate quinhydrone in a or matrix on the surface for portability and rapid activation in flow systems or localized measurements. For maintenance, electrodes are stored in an acidic quinhydrone solution to preserve the couple's activity and prevent degradation. Safety considerations during construction emphasize handling quinhydrone and its components as mild irritants; p-benzoquinone can cause skin and eye irritation, while quinhydrone itself is toxic if ingested and should be managed with gloves, eye protection, and proper ventilation. Preparations must avoid alkaline conditions, as they disrupt the redox equilibrium, and waste should be disposed of according to local chemical regulations.

Potential Measurement

The potential of the quinhydrone electrode is measured by immersing a indicator electrode and a , typically the (SCE), into the test solution saturated with quinhydrone. A high-impedance or is used to record the cell potential E_\text{cell} = E_\text{quinhydrone} - E_\text{reference}, ensuring minimal current draw to avoid . Calibration assumes a Nernstian response and is performed against standard buffers at pH 4.00 and 7.00, prepared by saturating them with quinhydrone. The pH of an unknown solution is then calculated as \text{pH} = \frac{E^\circ - E - E_\text{ref}}{0.059} at 25°C, where E^\circ is the standard potential of the quinone-hydroquinone couple (0.699 V vs. SHE), E is the measured cell potential, and E_\text{ref} is the reference electrode potential; temperature adjustments replace 0.059 with \frac{2.303 RT}{F}. The reaches a stable potential in 1-2 minutes after immersion, with a linear response over the range of 1 to 8. In ideal conditions, typical precision is ±0.02 units, though corrections for liquid junction potentials may be required in solutions with significant gradients. For example, at 4.00 and 25°C, the quinhydrone potential is approximately 0.22 V vs. .

Applications

pH Determination

The quinhydrone electrode serves as a primary tool for pH measurement in aqueous solutions, particularly in acidic media. The standard protocol entails preparing the sample by adding excess quinhydrone (typically 0.5 to 1.0 g per 100 mL of solution) to establish equilibrium between quinone and , followed by immersing a bright wire or foil into the mixture. The potential is then measured against a , such as a , using a . The is calculated from a derived from standard buffer solutions, where the electrode potential varies linearly with according to the for the -quinone couple. This method provides distinct advantages over the traditional hydrogen electrode, including simpler setup without requiring hydrogen gas bubbling or platinized electrodes, quicker attainment of (often within minutes), and applicability to viscous or non-conductive samples where gas diffusion is impractical. These features made it particularly valuable for routine analyses in the early . The electrode is reliable for values up to approximately 8, offering accuracy within 0.02 pH units when calibrated properly, and has been employed in potentiometric titrations of weak acids, such as acetic acid, to detect equivalence points through sharp potential breaks. Practical applications include testing, where the electrode facilitates direct measurement in soil suspensions to assess acidity for agricultural purposes. In food analysis, it was used in for evaluating acidity in juices via early Beckman pH meters equipped with quinhydrone options, aiding in the citrus industry. For pharmaceutical buffers, the electrode enabled precise adjustments in acidic formulations, ensuring stability in drug preparations. Historically, the quinhydrone electrode saw widespread adoption in laboratories from the to the , introduced by Biilmann in 1921 as a rapid alternative to cumbersome methods, before electrodes became dominant due to their broader range.

Nonaqueous Solvents

The quinhydrone electrode demonstrates utility in nonaqueous solvents such as alcohols, acetone, and (DMSO), where glass electrodes are ineffective due to poor performance in low-dielectric or high-resistance solutions. Its operation relies on the of quinhydrone in these solvents, enabling the to respond to activity in a manner analogous to aqueous systems, thus allowing pH-like measurements in organic environments. Reproducible results have been achieved across a variety of nonaqueous , making it a viable for potentiometric determinations where traditional electrodes fail. Preparation for nonaqueous applications involves the with quinhydrone at concentrations of 0.1–1 g per 100 mL to establish the required quinone-hydroquinone , often with excess solid present to maintain . -compatible electrodes, such as Ag/Ag⁺, are paired with the quinhydrone electrode to minimize junction potentials and ensure in media. These adjustments account for the lower and differing properties of nonaqueous s compared to water. Key applications include the potentiometric determination of pKₐ values for weak acids in nonaqueous media, where the electrode facilitates endpoints in solvents like or . It is also employed in analyzing the acidity of electrolytes, particularly in organic-based systems, and in pharmaceutical studies assessing under varying proton activities in mixed solvents. The standard potential E° exhibits shifts influenced by the solvent's dielectric constant, requiring empirical for precise measurements. In modern research, the quinhydrone electrode occupies a niche role in studies of aprotic solvents, despite its overall rarity in contemporary routine analysis, supporting specialized investigations into redox behavior and acid-base equilibria in advanced materials like flow battery components.

Limitations

Practical Constraints

The quinhydrone electrode exhibits significant limitations in its operational pH range, primarily due to the ionization of hydroquinone, which begins appreciably above pH 8 and disrupts the quinone-hydroquinone equilibrium essential for stable potential measurements. This ionization leads to the formation of hydroquinone anions (HQ⁻), causing potential drift and errors exceeding ±0.2 pH units, rendering the electrode unreliable for alkaline solutions. Temperature sensitivity further constrains the electrode's performance, where the potential deviates from the expected linear response to pH changes at extreme temperatures. Stability decreases notably above 30°C, and the of the standard potential is approximately -0.00074 V/°C, necessitating compensation adjustments of about 0.003 units per °C to maintain accuracy. The electrode's is limited by the gradual of quinhydrone crystals in aqueous solutions, which alters the equilibrium over time and requires fresh addition of crystals for each measurement, making it unsuitable for continuous monitoring beyond approximately 1 hour. Prepared quinhydrone standards typically remain viable for only 8 hours before necessitates daily renewal. Compared to glass electrodes, the quinhydrone electrode is less versatile, confined to narrower and temperature ranges, which contributed to its in routine applications after the as more robust alternatives emerged. While it offers low-cost construction using simple wire and readily available quinhydrone, its disposable nature—requiring repeated preparation—contrasts with the durability and reusability of glass probes.

Interfering Factors

The accuracy of the quinhydrone electrode can be compromised by strong oxidizing or reducing agents present in the sample, which react with the / couple and alter the [Q]/[H₂Q] ratio, thereby shifting the measured potential. Examples include oxidizing agents such as Fe³⁺, (MnO₄⁻), and dichromate (Cr₂O₇²⁻) ions, as well as reducing agents like (I⁻), titanous (Ti³⁺), and chromous (Cr²⁺) ions. These interferences can lead to significant deviations in pH readings, particularly in samples with redox-active species. Complexing agents, such as proteins or chelators, can bind to or , disrupting the equilibrium and reducing the electrode's response sensitivity. This effect is particularly pronounced in biological samples, where organic macromolecules may cause errors of up to ±0.5 units by interfering with the availability of the pair. High ionic strength in the sample solution affects the activity coefficients of hydrogen ions and the quinhydrone species, introducing a "salt error" that shifts the . This deviation arises from non-ideal behavior in concentrated solutions and can be corrected using Debye-Hückel theory to adjust for changes in ionic activities. Pressure effects on the quinhydrone electrode are generally minimal under normal conditions, though elevated pressures may alter the of quinhydrone, potentially influencing the of the couple. To mitigate these interferences, samples can be diluted to reduce concentrations of -active or complexing agents and ; an inert atmosphere, such as purging, minimizes oxygen-related oxidation; and pre-treatment with antioxidants may stabilize -sensitive components. Duplicate measurements and comparison against standard buffers are recommended to verify and correct for residual effects.

References

  1. [1]
    [PDF] Exercise 6 POTENTIOMETRIC MEASUREMENT OF pH
    The quinhydrone electrode is a type of redox electrode which can be used to measure the hydro-gen ion concentration (pH) of a solution in a chemical experiment.Missing: history | Show results with:history
  2. [2]
  3. [3]
    Pillars of modern electrochemistry: a brief history
    He also worked on the quinone-hydroquinone transformation, which became the basis for Biilmann s quinhydrone electrode for measuring the acidity of solutions.
  4. [4]
    [PDF] Ion-selective electrodes - NIST Technical Series Publications
    Chapter 1. THEORY OF MEMBRANE ELECTRODE POTEN-. TIALS: AN EXAMINATION OF THE PARAMETERS DETER-. MINING THE SELECTIVITY OF SOLID AND LIQUID ION. EXCHANGERS AND ...
  5. [5]
    Quinhydrone | C12H10O4 | CID 7801 - PubChem - NIH
    Quinhydrone is an addition compound. It contains a 1,4-benzoquinone and a hydroquinone. ChEBI. structure.Missing: complex | Show results with:complex
  6. [6]
    pH Electrode Theory - Cole-Parmer
    Oct 15, 2018 · The quinhydrone electrode is a piece of platinum or gold, not platinized, with a very small amount of quinhydrone [a equimolecular mixture of ...
  7. [7]
    Ways of Measuring pH - HORIBA
    (3) Quinhydron-Electrode Method. When quinhydrone is added to a solution, it separates into hydroquinone and quinone. Because quinone's solubility varies ...
  8. [8]
    article the use of the quinhydrone electrode for hydrion ...
    THE USE OF THE QUINHYDRONE ELECTRODE FOR HYDRION CONCENTRATION DETERMINATION ON SERUM ... Biilmann E. Ann. chim., xv (1921), p. 109. series 9. Google Scholar. 2 ...Missing: paper | Show results with:paper
  9. [9]
    [PDF] A comparison of the quinhydrone and hydrogen electrodes in ...
    Wallace and John Beek, jr. ABSTRACT. Measurements of pH are made with the hydrogenand quinhydrone electrodes in solutions of tanning extracts and in ...Missing: paper | Show results with:paper<|control11|><|separator|>
  10. [10]
    On the measurement of hydrogen-ion concentrations in soil by ...
    On the measurement of hydrogen-ion concentrations in soil by means of the quinhydrone electrode. Published online by Cambridge University Press: 27 March ...
  11. [11]
    Beckman Quinhydrone pH Meter
    Arnold Beckman invented his first pH meter in 1934 at the request of a chemist from the California citrus industry, who needed an accurate way to measure the ...
  12. [12]
    [PDF] OXIDATION—REDUCTION - Iowa State University Digital Repository
    hydrone electrode was displaced by the glass electrode for the practical measurement of pH. About the only work with the quinhydrone electrode in very ...
  13. [13]
    [PDF] The pH of the Skin Surface and Its Impact on the Barrier Function
    Since the beginning of the 1950s, the flat glass electrode was used more and more for skin pH measurements [4] . Schirren showed the equivalence between the ...
  14. [14]
    Mechanochemistry: A Green Approach in the Preparation of ...
    In this paper was informed the preparation of quinhydrone cocrystals grinding equimolar amounts of p-benzoquinone and hydroquinone. ... Synthesis Method. Int. J.<|control11|><|separator|>
  15. [15]
    Process for the preparation of quinhydrones - Google Patents
    For example, quinhydrones may be prepared by mixing equimolar quantities of a hydroquinone and a quinone in a suitable solvent. The purity and utility of ...Missing: cooling solubility
  16. [16]
    Quinhydrone | 106-34-3 - ChemicalBook
    Jan 27, 2025 · Quinhydrone Properties: Melting point 167-172 °C (lit.) Boiling point 285 °C Density 1.32 bulk density 300kg/m3 refractive index 1.4270 (estimate)Missing: composition physical
  17. [17]
  18. [18]
    Quinhydrone, 97% 25 g | Buy Online | Thermo Scientific Chemicals
    4–8 day delivery 30-day returnsIt provides an alternative to the commonly used glass electrode in a pH meter. ... Percent Purity, 97%. Chemical Name or Material, Quinhydrone. Show More Show ...
  19. [19]
    [PDF] UV-Vis spectrophotometry of quinone flow battery electrolyte for in ...
    Nov 13, 2017 · These spectra are fit across this wavelength range to obtain a quinhydrone equilibrium constant (KQHQ) and a molar attenua- tion constant (εQHQ ...
  20. [20]
    II. Chemical Foundations – CHEM 1120 Lab Manual
    ... quinhydrone. When quinhydrone is dissolved in solvent, it makes a solution ... equal concentrations, leaving a function that simply depends on the ...
  21. [21]
    Solved 3. The quinhydrone electrode was introduced in 1921 - Chegg
    Oct 30, 2017 · The left half-cell reaction is. OH +2H + 2e OH where quinone is reduced to hydroquinone with standard reduction potential given by E0.700 V.
  22. [22]
    Quinhydrone - an overview | ScienceDirect Topics
    Quinhydrone is defined as a charge transfer complex in which quinone acts as the electron acceptor and diphenol serves as the electron donor. AI generated ...
  23. [23]
    CCL.—The temperature coefficient of the quinhydrone electrode
    —The temperature coefficient of the quinhydrone electrode. E. Biilmann and I. Krarup, J. Chem. Soc., Trans., 1924, 125, 1954 DOI: 10.1039/CT9242501954.Missing: dT | Show results with:dT
  24. [24]
    None
    ### Summary of Quinhydrone Electrode from the Document
  25. [25]
    [PDF] Broadley-James
    Equation 2. Eh = E + ER. Where: ER = standard potential of the reference electrode. Please note that the ...
  26. [26]
    None
    ### Summary of Quinhydrone Electrode Construction and Preparation
  27. [27]
    [PDF] Alternate ORP Calibration Procedure
    The alternate ORP calibration uses Quinhydrone saturated pH buffers to create stable mV standard solutions, outside the range of commercial buffers.
  28. [28]
  29. [29]
  30. [30]
    Quinhydrone, 97% - Fisher Scientific
    CA$192.42Product Suggestions. Videos. Safety and Handling. Safety and Handling. GHS H Statement H301-H315-H319-H335 Toxic if swallowed. Causes skin irritation. Causes ...Missing: quinone | Show results with:quinone
  31. [31]
    Quinone | C6H4O2 | CID 4650 - PubChem - NIH
    General First Aid: · Call 911 or emergency medical service. · Ensure that medical personnel are aware of the material(s) involved, take precautions to protect ...
  32. [32]
    The “Salt Error” and Normal Electrode Potential of the Quinhydrone ...
    The temperature dependence of the salt error of the quinhydrone electrode in aqueous lithium chloride solution. Journal of Electroanalytical Chemistry and ...
  33. [33]
    [PDF] field measurement of orp (pdf) - US EPA
    This document describes procedures, methods and considerations to be used and observed when conducting field Oxidation-Reduction Potential (ORP) measurements ...<|control11|><|separator|>
  34. [34]
    [PDF] Measurement of pH
    pH is measured using pH indicators, which change color, or the potentiometric method, which is the most accurate method.
  35. [35]
    [PDF] The Determination of Hydrogen Ion Concentration by the ...
    Quinhydrone in solution reversibly dissociates to quinone and ... is a constant for the quinhydrone electrode, established by using a solution ...
  36. [36]
    STUDIES ON pH MEASUREMENTS. (Part I) - J-Stage
    The measurement operation of quinhydrone electrode is simpler than that of hydrogen electrode, and also the stability of the electric potential is quicker.<|control11|><|separator|>
  37. [37]
    the application of the quinhydrone electrode to electrometric acid ...
    Here [H2] equals 10-23.65 atmospheres when the ratio hydro- quinone to quinone is unity as is the case with quinhydrone, and the quinhydrone electrode p, ...<|control11|><|separator|>
  38. [38]
    [PDF] A Comparison of Different Types of Glass Electrode for Determining ...
    During the past decade the quinhydrone electrode has been used extensively for determining the hydrogen-ion concentration of.
  39. [39]
    THE QUINHYDRONE ELECTRODE METHOD OF HYDROGEN ION ...
    THE. QUINHYDRONE. ELECTRODE METHOD. OF HYDROGEN. ION. CONCENTRATION. MEASUREMENTS. By E. M. Chowthku, D.Sc, F.I.C.. Adequate testimony to the im])ortance of the ...<|control11|><|separator|>
  40. [40]
    Acid–base equilibrium in non-aqueous medium - RSC Publishing
    Jan 22, 2024 · One mM concentration of MM1 is prepared as a stock solution in an ACN medium. As well as all the acids and bases are prepared at one mM of ...
  41. [41]
    Quinone voltammetry for redox-flow battery applications
    Sep 1, 2022 · Electrochemistry in aprotic solvents containing anhydrous perchloric acid: Electroreduction behavior of quinones. Electrochim. Acta, 38 (1993) ...
  42. [42]
    None
    ### Practical Constraints of Quinhydrone Electrode
  43. [43]
    [PDF] 6.5 REDUCTION- OXIDATION POTENTIAL (ELECTRODE METHOD)
    Quinhydrone solution is sometimes used but is not recommended because it is significantly less stable above 30°C and its tempera- ture dependence is not as well ...
  44. [44]
    [PDF] Manual: Theory and Practice of pH Measurement
    The potential of the measuring electrode depends only on the pH of the solution. ... The voltage of a pH measuring cell as a function of temperature and pH is ...
  45. [45]
    [PDF] REDOX MEASUREMENTS their theory and technique
    In prac- tice, the pH glass electrode has replaced it. NOTE: Some readers may ... The quinhydrone electrode can be used only in the pH range 0 - 9, as ...
  46. [46]
    STUDY ON THE INFLUENCE OF HIGH HYDROSTATIC ... - J-Stage
    But he failed to demonstrate actual changes of pH of electrolyte solutions by means of a small-sized quinhydrone electrode installed in high pressure bomb.
  47. [47]
    Electrochemical Study of Quinone-Mediated Extracellular Electron ...
    Nov 13, 2024 · ... water pollution by industrial and ... Specifically, controlled-potential amperometric studies apply a constant electrochemical potential ...