Fact-checked by Grok 2 weeks ago

Cellulose insulation

Cellulose insulation is a thermal insulation material produced primarily from recycled paper products, such as newsprint, with a recycled content typically ranging from 82% to 85%, and treated with fire-retardant chemicals including boric acid, borax, or ammonium sulfate to enhance safety and durability. It is manufactured by shredding and milling the paper into fibers, then impregnating them with retardants during a low-energy process that ensures uniform distribution for fire resistance compliant with standards like ASTM C739. With an R-value of 3.2 to 3.8 per inch, cellulose provides strong thermal resistance and excels in reducing air infiltration by up to 74% when densely packed, outperforming some fiberglass alternatives in empirical airtightness tests. Its loose-fill or dense-pack forms are blown into attics, walls, and cavities, offering superior sound absorption and pest deterrence from the borate treatments, though settling over time and moisture sensitivity necessitate professional installation and vapor barriers in humid climates. While praised for sustainability due to wastepaper utilization, early formulations faced scrutiny over retardant efficacy, but modern variants demonstrate low flame spread and smoldering resistance in controlled evaluations.

History

Origins and pre-20th century uses

The use of cellulosic materials for insulation predates modern formulations, originating from natural plant fibers exploited for their thermal properties in ancient construction. Straw and reeds, abundant cellulosic resources, were incorporated into building practices over 10,000 years ago, serving as infill in walls and thatch for roofs to mitigate heat transfer and drafts. These materials provided passive insulation through trapped air within their fibrous structure, a principle later quantified in thermal resistance terms but empirically observed in early shelters. In Europe and North America during the medieval and early modern periods, straw mixed with mud or clay formed wattle-and-daub walls and cob structures, enhancing thermal retention in vernacular architecture. Viking-era buildings, for example, employed mud-straw composites stuffed between wooden frames to retain hearth warmth against northern climates. Such applications relied on the low conductivity of dry plant matter, though susceptibility to moisture and settling limited longevity without modern treatments. By the 18th century, refined uses emerged in American colonial building; Thomas Jefferson designed Monticello with a form of cellulose insulation starting in 1769, likely utilizing processed plant fibers or wood byproducts to fill cavities and improve energy efficiency in the brick-heavy structure. This approach reflected growing awareness of insulation's role in comfort, predating industrialized production. In the 19th century, industrialization increased availability of wood waste, leading to widespread adoption of sawdust and planer shavings as loose-fill insulation in wall and attic spaces of frame houses. Homes constructed around 1840 often featured these materials packed densely to achieve R-values comparable to early bulk fills, with borax sometimes added for pest deterrence. Dry sawdust, in particular, proved effective when installed to minimize voids, drawing from lumber mill surpluses and offering a cost-effective alternative to scarcer animal-based insulators. These pre-20th century practices laid the groundwork for cellulose insulation by demonstrating the viability of recycled or byproduct plant fibers, though fire risks and uneven performance prompted later innovations.

20th century commercialization and fire safety improvements

Cellulose insulation emerged as a commercial product in the United States during the 1920s, initially produced by grinding recycled newspapers into loose-fill form for use in attics and walls, capitalizing on the abundance of paper waste from expanding print media. Early formulations included minimal chemical treatments, such as borax for pest resistance, but lacked robust fire retardants, limiting adoption due to flammability risks. By the 1950s, the material gained broader market traction amid post-World War II housing booms, comprising up to newspaper, cardboard, or sawdust, and benefiting from its low cost relative to emerging alternatives like fiberglass. Fire safety concerns plagued early cellulose insulation, as untreated or inadequately treated paper fibers readily ignited and smoldered, contributing to structural fires and prompting regulatory scrutiny. In response, manufacturers introduced fire retardants like ammonium salts in the 1950s, which partially mitigated combustion but introduced secondary problems, including corrosion of metal wiring and fixtures due to chemical leaching in moist conditions. These issues intensified in the 1970s amid rapid industry growth— with cellulose capturing 20% of the U.S. insulation market by 1975—exacerbated by inconsistent treatment levels among small producers. The pivotal advancement occurred in 1978, when the U.S. Consumer Product Safety Commission (CPSC) mandated federal standards under 16 CFR 1209, requiring cellulose to achieve a maximum smolder extension of 3.5 inches, char length under 8 inches, and critical radiant flux exceeding 0.12 W/cm² to ensure resistance to ignition and flame spread. This necessitated a minimum 25% fire retardant content by dry weight, driving a shift to non-corrosive borate-based compounds like boric acid and sodium borate, which provided superior char formation and smoke suppression without the acidity of prior phosphates or sulfates. Compliance testing consolidated the industry, eliminating substandard producers and enabling cellulose to attain ASTM E84 Class I fire ratings, where properly installed material resists flame penetration for extended durations in wall assemblies. These reforms, alongside the 1970s oil crises boosting demand for energy-efficient retrofits, propelled cellulose to 15-20% market share by the early 1980s.

Post-2000 regulatory changes and market shifts

Following the adoption of the 2003 edition of the International Energy Conservation Code (IECC), subsequent updates in 2006, 2009, 2012, 2015, 2018, and 2021 progressively raised minimum insulation R-value requirements across U.S. climate zones to enhance building energy efficiency, with cellulose insulation complying via its dense packing that minimizes thermal bridging and air infiltration as per ASTM C739 and C1149 standards. These codes mandate higher ceiling R-values (e.g., R-49 in many zones) and wall insulation levels, favoring materials like cellulose that achieve settled densities exceeding 3.0 lb/ft³ for sustained performance without significant settling beyond initial design allowances. The 2021 IECC specifically endorses blown-in cellulose for cavity applications when installed to labeled coverage charts, integrating it into prescriptive compliance paths for residential envelopes. The 2022 Inflation Reduction Act introduced the Energy Efficient Home Improvement Credit, effective January 1, 2023, offering 30% of qualified insulation costs up to $1,200 annually for materials meeting 2021 IECC standards, a tripling from the prior 10% rate under Section 25C, thereby incentivizing cellulose retrofits in attics and walls. Dense-pack cellulose qualifies as an air-sealing measure under this provision, provided it adheres to manufacturer specifications for moisture control and fire retardancy per 16 CFR Part 1209. Concurrently, the U.S. Department of Housing and Urban Development's 2024 amendments to Manufactured Home Construction and Safety Standards incorporated updated insulation efficacy criteria, aligning with IECC baselines and supporting cellulose use in factory-built housing. Post-2000 market dynamics reflect a shift toward sustainable amid rising costs and mandates, with global cellulose demand growing at a compound annual rate of approximately 4.5% from 2024 onward, propelled by its 75-85% recycled paper content and lower embodied carbon compared to or foam alternatives. Adoption surged in residential retrofits, capturing share from synthetic insulators due to cellulose's superior air barrier properties—reducing infiltration by up to 25% in dense applications—and alignment with certification preferences for recycled materials since the system's expansion around 2000. U.S. production stabilized under the 2002 EPA Standards for Hazardous Pollutants for manufacturing, with minor 2025 amendments ensuring emission controls without disrupting supply, while tax credits and code compliance have driven volume increases in loose-fill and stabilized variants for attics and walls.

Manufacturing Process

Raw material sourcing and preparation

The primary raw material for cellulose insulation consists of recycled fibers, predominantly post-consumer newsprint, , and office , which typically comprise 75% to 85% of the insulation's by weight. These fibers originate from wood pulp processed into products, with the U.S. of Energy noting a recycled content of 82% to 85% in standard formulations. Sourcing occurs through municipal and commercial streams, where segregated waste is collected from households, businesses, and operations, then baled and shipped to insulation manufacturers, minimizing reliance on virgin timber. Preparation begins with unloading and inspecting bales for contaminants like adhesives or non-paper debris, ensuring only clean, dry material advances. The is then mechanically shredded into strips approximately 5 long using shredders, followed by hammermilling to defibrillate the strips into individual cellulose fibers roughly 1-3 mm in length. During this stage, impurities—such as metal clips, plastics, and inks—are removed via magnetic separators, air classifiers, and vibrating screens to achieve fiber purity levels exceeding 95%, preventing defects in the final product. This mechanical processing yields a fluffy, uniform fiber mass ready for chemical impregnation, with energy inputs primarily from for milling equipment.

Chemical treatments and production methods

Cellulose insulation is primarily treated with borate-based compounds, including (H₃BO₃) and (borax, Na₂B₄O₇·10H₂O), to achieve fire retardancy, along with secondary benefits for and resistance. These inorganic salts, typically comprising 10-20% of the material's weight, function by releasing bound during heating to cool the , forming a glassy layer that inhibits oxygen access and flame spread, and suppressing smoldering . Borates also deter and by interfering with their and fungal growth by altering and depriving organisms of essential nutrients. Ammonium sulfate ((NH₄)₂SO₄) or phosphate additives have historically been incorporated in some formulations for additional flame suppression via endothermic decomposition and acid gas release, though borates predominate in modern products due to reduced corrosivity risks to metal framing. Treatment levels are calibrated to meet standards like ASTM E84 for surface burning (Class 1 rating, flame spread ≤25) and CAN/ULC-S102, with boric acid often applied at approximately 12% and borax at 6% for optimal efficacy against ignition and decay. In production, recycled newsprint or —sourced at 75-85% of the feedstock—is first processed through shredders and hammermills to fiberize into 1-5 mm particles, with magnetic separators removing contaminants like staples. The powdered and any co-additives are then dry-blended uniformly into the fibers during or post-milling, ensuring even distribution via high-shear mixers to prevent settling or clumping. Final grinding classifies the material by for loose-fill (coarser) or dense-pack applications, followed by quality checks for chemical retention and content below 10% to maintain stability. Alternative vapor-phase methods, such as methyl borate , have been explored for deeper penetration but remain less common than dry mixing in commercial scales.

Product Types

Loose-fill cellulose

Loose-fill cellulose insulation consists of granulated recycled paper fibers, typically 75-85% post-consumer newsprint and cardboard, treated with fire-retardant chemicals such as boric acid or ammonium sulfate to enhance resistance to flame spread, smoldering, and fungal growth. This form is pneumatically installed using specialized blowing machines that propel the material through hoses into open attics, cathedral ceilings, or enclosed wall cavities, allowing it to conform to irregular surfaces and fill gaps more effectively than rigid batts. The material achieves a settled density of approximately 1.4 to 2.3 pounds per cubic foot (22-37 kg/m³) in attic applications, with installation requiring adherence to manufacturer coverage charts that specify bag counts, machine settings, and initial blow thickness to account for settling. Settling occurs due to gravity and vibration, potentially reducing thickness by 10-20% over time in horizontal installations, necessitating an overblow of 12-20% beyond the target settled depth to maintain the nominal R-value of 3.2 to 3.8 per inch (0.89-1.06 per 25 mm). For example, to achieve R-38 in attics, coverage charts from producers like GreenFiber recommend minimum settled thicknesses of 13-15 inches at densities ensuring no more than 20% volume loss. In vertical wall applications, loose-fill is less common than dense-pack variants but can be used with netting or baffles to prevent fallback, targeting higher densities around 3.5-4.0 pounds per cubic foot (56-64 kg/m³). Thermal performance derives from the fibrous structure's ability to trap air and reduce convective heat flow, outperforming loose-fill fiberglass (R-2.2 to 2.7 per inch) at equivalent thicknesses while providing incidental air sealing that minimizes infiltration losses. However, efficacy depends on proper moisture management, as untreated cellulose is hygroscopic; borate treatments limit absorption to under 15% by weight before performance degradation, but exposure to prolonged humidity above 50% RH can foster mold if ventilation is inadequate. Standards from the Cellulose Insulation Manufacturers Association (CIMA) mandate compliance with ASTM C739 for loose-fill products, ensuring minimum fire resistance (Class 1 or 2 flame spread rating) and corrosion resistance under UL 723 testing. Compared to fiberglass, loose-fill cellulose offers superior sound attenuation (Noise Reduction Coefficient up to 0.65) due to denser packing and fiber flexibility, making it suitable for noise-prone areas, though it generates more dust during installation, requiring protective gear.

Dense-pack and stabilized cellulose

Dense-pack cellulose insulation involves pneumatically installing loose-fill cellulose into enclosed wall cavities at high density, typically achieving 3.5 to 4 pounds per cubic foot, to minimize settling and enhance air sealing. This method uses specialized equipment to blow the material through small holes drilled in the exterior sheathing or interior drywall, filling irregular spaces around wiring, pipes, and framing while exerting pressure to conform tightly to the cavity. Installation requires precise control to avoid over-compression, which could reduce R-value, and verification via density probes or borescopes to ensure uniformity. Stabilized cellulose refers to formulations or techniques that incorporate binders, tackifiers, or slight moistening to lock fibers in place, preventing or settling beyond what dense-packing alone achieves, particularly in vertical applications like retrofit walls. Unlike standard loose-fill, stabilization enhances long-term stability without relying solely on friction from high density, though it overlaps with dense-pack methods in practice. This approach is suited for hard-to-access cavities where dry blowing might leave voids, providing a semi-rigid matrix that resists compression over time. Both variants deliver an R-value of approximately 3.5 to 3.7 per inch, outperforming fiberglass batts in air leakage reduction by up to 38% due to their dense, fibrous structure that limits convective air movement within the assembly. They excel in acoustic performance, attenuating sound transmission by filling gaps that batts often miss, and offer inherent fire resistance from borate treatments, though dense-pack does not create a true air barrier assembly. Drawbacks include higher installation labor—up to 2-3 times longer than batts—and potential moisture retention if not paired with proper vapor control, as cellulose's hygroscopic nature can absorb ambient humidity without degrading if densities remain above 3.5 pounds per cubic foot. These methods are most effective in retrofits, where they conform to existing framing irregularities, but require experienced installers to avoid under- or over-packing, which could compromise thermal continuity.

Wet-spray and low-dust variants

Wet-spray cellulose insulation, also known as damp-spray or stabilized cellulose, is applied by mixing dry cellulose fibers with water—and typically a starch- or resin-based adhesive—and pneumatically spraying the slurry into open wall cavities, attics, or other enclosed spaces. This method achieves installed densities of 3.5 to 4.5 pounds per cubic foot, which interlocks the fibers to resist settling over time, often limited to less than 1% annually under standard conditions. The adhesive promotes adhesion to substrates and irregular surfaces, such as around electrical wires, pipes, and framing members, thereby reducing air leakage paths and convective heat transfer more effectively than loose-fill or batt alternatives. Upon application, the wet mixture expands slightly to fill voids before drying and curing, typically within 24 to 48 hours depending on ambient humidity and ventilation, forming a rigid, seamless barrier. Thermal performance yields R-values of 3.6 to 3.8 per inch at settled densities above 3.0 pounds per cubic foot, comparable to dense-pack cellulose but with superior sound attenuation due to the higher packing factor. Installation requires specialized equipment, including a spray rig with moisture metering to maintain water content at 20-30% by weight, preventing over-saturation that could lead to extended drying times or mold risks if moisture exceeds 20% post-installation. Advantages include faster application rates—up to 1,000 square feet per hour—and lower material volumes (10-20% less than dry dense-pack) for cost savings of approximately $0.10 to $0.20 per square foot, though improper water ratios can compromise R-value by up to 15% through fiber clumping. Low-dust variants modify standard loose-fill or blown-in through refined shredding, fiber binding agents, or electrostatic treatments to minimize airborne particulates during pneumatic , reducing installer exposure and site contamination by 50-70% compared to conventional formulations. These products maintain core properties like R-3.2 to 3.6 per inch and fire retardancy from treatments but prioritize user safety in enclosed or occupied spaces, with dust emission rates below 5 mg/m³ during blowing per industry benchmarks. They are suited for or sidewall retrofits where is limited, though efficacy depends on certified equipment to avoid velocity-induced fiber breakup; long-term performance mirrors untreated , with no added settling risks.

Thermal Performance

R-value and heat transfer properties

Cellulose insulation's thermal resistance is quantified by its R-value, a measure of the material's ability to resist heat flow, typically expressed per inch of thickness under standardized conditions such as ASTM C518. Loose-fill cellulose generally achieves an R-value of 3.2 to 3.8 per inch, depending on density and installation method, which is comparable to or slightly superior to fiberglass loose-fill at 2.2 to 2.7 per inch. This performance stems from the material's thermal conductivity of approximately 0.040 W/m·K, enabling effective reduction of conductive heat transfer through the fibrous matrix derived from recycled paper. In dense-pack applications, such as wall cavities, cellulose can exhibit higher effective R-values per inch due to increased material density (typically 3.5 to 4.0 lb/ft³), which further suppresses convective air movement within the insulation mass compared to lower-density attic installations. Heat transfer in cellulose primarily occurs via conduction through the solid fibers and stagnant air pockets, with convection minimized by the interlocking fiber structure that traps air and prevents bulk airflow. Radiative heat transfer is also attenuated by the opaque, light-absorbing nature of the recycled paper fibers, though it contributes less significantly than conduction in typical building envelopes. Long-term R-value stability requires accounting for settling in loose-fill forms, where manufacturers specify values based on settled density rather than initial blown-in thickness, as per industry standards like ASTM C739; for instance, a typical attic installation may settle by 10-20% over time, necessitating adjusted coverage charts to achieve target R-values such as R-38. Experimental data from sources like Oak Ridge National Laboratory confirm that properly installed cellulose maintains thermal resistance effectively, with minimal drift after initial settling, outperforming some batt insulations in real-world attic conditions due to better air infiltration resistance.

Factors affecting long-term effectiveness

The long-term thermal effectiveness of cellulose insulation, measured primarily by sustained R-value, is influenced by settling in loose-fill applications, where material compaction over time can reduce installed thickness by 10-20%, potentially leading to gaps and diminished heat transfer resistance unless initial installation exceeds settled specifications. Manufacturers typically rate R-values based on settled density (1.5-2.0 lb/ft³ for loose-fill, yielding 3.2-3.8 per inch), requiring installers to apply additional volume to achieve target performance after stabilization, which occurs within the first year post-installation. Moisture content significantly degrades thermal conductivity, as cellulose's hygroscopic nature allows absorption up to 15-20% by weight, increasing heat transfer rates and lowering effective R-value by up to 50% in saturated conditions; prolonged exposure risks permanent structural breakdown and mold proliferation, though the material can recover properties upon drying if not chemically compromised. Studies indicate that in wall assemblies, slow drying times (up to five months in moderate climates) exacerbate risks, emphasizing the need for vapor-permeable barriers and proper ventilation to maintain long-term efficacy. Maintained density plays a causal role, with dense-pack variants (3.5+ /ft³) exhibiting less and R-values around 3.65 per inch but potential under load in enclosed cavities, while variations in ambient further modulate by 5-10% across seasonal ranges. quality, including avoidance of over-blowing or under-compaction, directly impacts these factors, as voids from poor application amplify convective losses over decades. Overall, empirical data from evaluations confirm that while offers stable performance in controlled environments, unmitigated or ingress can reduce lifespan effectiveness to 20-50 years, contingent on site-specific conditions.

Fire and Chemical Safety

Fire retardancy mechanisms and testing

Cellulose insulation achieves fire retardancy primarily through chemical treatments that inhibit ignition, flame spread, and smoldering combustion. The most common additives are boric acid (borates) and ammonium sulfate, applied at concentrations of approximately 15-25% by weight to recycled paper fibers. Boric acid functions as a Lewis acid catalyst, promoting dehydration of cellulose chains at elevated temperatures rather than thermal depolymerization into combustible volatiles; this facilitates char formation—a carbon-rich, insulating layer that shields underlying material from oxygen and heat. Ammonium sulfate complements this by decomposing endothermically to release ammonia gas and water vapor, diluting flammable pyrolysis products and smothering potential flames. The dense, fibrous matrix of settled cellulose further resists convective heat transfer and radiant fire penetration, limiting oxygen access to fuel sustained combustion. These mechanisms distinguish treated cellulose from untreated cellulosic materials, which ignite readily at 300-400°C due to rapid volatile release. Borates remain effective across a range of fire exposures, melting into a glassy barrier that encapsulates fibers without volatilizing significantly, though prolonged high-heat exposure above 450°C can induce smoldering if densities are suboptimal. Empirical studies confirm that borate-treated insulation exhibits self-extinguishing behavior in smoldering tests, with char yields exceeding 30% under oxidative pyrolysis, reducing heat release rates by up to 70% compared to untreated cellulose. Fire performance is evaluated under standardized protocols to ensure compliance with building codes. The primary U.S. standard, ASTM C739, mandates tests for loose-fill cellulose including critical radiant flux for smoldering resistance (minimum 0.12 W/cm² without ignition) and specific optical density for smoke development (≤450). Surface flame spread is assessed via ASTM E84 (Steiner tunnel), where compliant products achieve a Class 1 rating with flame spread indices ≤25 and smoke-developed indices ≤50, outperforming many organic foams. Additional federal requirements under 16 CFR Part 1209 include smoldering combustion resistance, where samples must not exceed 3% mass loss after 28 days under a smoldering cigarette, and the attic floor radiant panel test (AFRPT) simulating attic fire spread. Full-wall fire endurance, such as ASTM E119, has been demonstrated for cellulose in assemblies achieving 2-hour ratings without flame penetration. These tests prioritize empirical ignition thresholds over modeled predictions, revealing that while cellulose resists open flaming, improper installation can compromise performance by allowing air voids that accelerate heat transfer.

Health risks from additives and emissions

Cellulose insulation typically incorporates boric acid or sodium borate (borates) at concentrations of 0.5% to 2.5% by weight, along with ammonium sulfate at 2.5% to 10%, to provide fire retardancy and pest resistance. Borates act as irritants to the eyes, skin, and upper respiratory tract upon direct contact or inhalation of dust laden with these chemicals, with animal inhalation studies at 5 mg/kg showing mild, transient lung inflammation without progression to fibrosis. Ammonium sulfate contributes minimal systemic toxicity but can decompose to release ammonia gas under humid or high-temperature conditions, potentially causing respiratory irritation or odor. During installation, airborne total dust levels frequently exceed OSHA permissible exposure limits (15 mg/m³ for 8-hour time-weighted average), though respirable fractions remain low (<11% of total, with mass median aerodynamic diameters >10 μm), limiting deep lung penetration. NIOSH assessments of applicators documented eye and nasal irritation in 35% of workers each, morning phlegm in 25%, and coughing in 22%, with symptoms correlating temporally to exposure and resolving during time away from work; no evidence of occupational asthma or bronchial hyperreactivity was found. Bulk borate levels in insulation (4,700–26,000 μg/g extractable) indicate low potential for significant airborne dissemination, but engineering controls like moistening systems and NIOSH-approved N95 respirators are recommended to mitigate dust and additive exposures. Post-installation emissions from cellulose insulation are characterized by low volatile organic compound (VOC) levels, with formaldehyde concentrations measured at approximately 12.7 μg/m³ in chamber tests, well below certification thresholds like GREENGUARD's 61.4 μg/m³ limit. Attic monitoring in occupied residences detected VOCs such as furfural, acetic acid, and methanol at parts-per-trillion averages, attributed partly to cellulose decomposition but without exceeding indoor air quality guidelines; these emissions decline over time and are lower than those from plywood or other wood-based materials. Ammonia off-gassing from ammonium sulfate is infrequent and odor-detectable rather than hazardous in sealed installations, posing negligible chronic risks to occupants when properly applied. Overall, cellulose is classified as non-hazardous for residential use due to its low-emission profile compared to synthetic alternatives.

Acoustic and Mechanical Properties

Sound attenuation capabilities

Cellulose insulation's sound attenuation arises from its dense, fibrous matrix—typically 3 to 4 pounds per cubic foot for loose-fill variants—which traps airborne sound waves, converting acoustic energy into heat through viscous and frictional damping within the porous structure. This mechanism provides superior noise reduction compared to less dense materials like fiberglass batts, particularly for mid- and high-frequency sounds. The noise reduction coefficient (NRC), which quantifies absorption across 250 to 2000 Hz frequencies, averages 0.80 or higher for cellulose insulation, enabling effective dampening of echoes and reverberation in enclosed spaces such as attics and ceilings. Sound absorption coefficients rise with installation thickness; for example, samples at 100 mm thickness exhibit markedly higher absorption than thinner layers (25 mm), with peaks in the 100 to 3000 Hz range and slight enhancements under elevated humidity due to increased airflow resistivity. For transmission through partitions, cellulose contributes to sound transmission class (STC) ratings of 45 to 70 in complete wall assemblies, depending on cavity depth and flanking elements; blown-in cellulose in a 2x4 wood-frame wall adds approximately 5 dB of reduction, rising to 9 dB in 2x6 configurations, outperforming uninsulated or fiberglass-filled equivalents by filling voids and adding mass. These ratings, verified in laboratory tests by bodies like the National Research Council Canada, underscore cellulose's efficacy for airborne noise isolation in residential and commercial settings, though performance diminishes for low-frequency or impact noises without supplementary barriers.

Weight, settling, and structural impacts

Cellulose insulation exhibits a higher density than many alternatives, such as fiberglass, with loose-fill applications in attics typically installed at 1.32 to 1.65 pounds per cubic foot to achieve settled densities around 2 pounds per cubic foot for target R-values. Dense-pack installations in walls or cavities require 3 to 4 pounds per cubic foot to ensure self-support and minimize voids. This density is approximately three times that of blown-in fiberglass, which ranges from 0.5 to 1 pound per cubic foot, resulting in greater material mass for equivalent thermal performance. Settling occurs primarily in loose-fill cellulose due to gravitational compaction over time, with manufacturers estimating rates of about 20% in attics, necessitating initial over-installation to maintain labeled R-values after settlement—for instance, an R-49 attic layer may compress by approximately 1.5 inches. Dense-pack methods at 3.5 pounds per cubic foot or higher substantially reduce or eliminate settling by achieving a friction-locked state, as confirmed in field observations and lab tests under static conditions. Experimental studies indicate settling is exacerbated by dynamic factors like vibration or outdoor exposure but minimized in enclosed, stable building environments. Long-term monitoring, such as Oak Ridge National Laboratory attic tests, accounts for this by specifying settled thicknesses and densities in product labels. The added weight from cellulose imposes structural demands, particularly in retrofits of older buildings, where attic loads can reach 1.16 pounds per square foot for R-38 installations, potentially straining ceilings or rafters if not assessed. Building codes require verification of dead load capacity before installation, as excessive cellulose—beyond 2 pounds per cubic foot in open-blown attics—may overload lightweight trusses or aged framing without reinforcement. In walls, dense-pack's higher mass (up to 3.5 pounds per cubic foot) distributes evenly but demands stud spacing checks to avoid sagging or compression failures over decades. No widespread evidence links properly installed cellulose to structural failures, though under-installation risks from settling can indirectly compromise load paths if voids form. Engineers recommend pre-installation load calculations, especially in seismic zones, to mitigate risks from the material's permanence once placed.

Moisture Management and Durability

Water absorption and vapor permeability

Cellulose insulation, derived from plant fibers, is inherently hygroscopic, readily absorbing water vapor through hydrogen bonding interactions with its cellulose structure, which enables it to achieve equilibrium moisture contents of 8-12% under typical indoor relative humidity conditions of 40-60%. This absorption capacity buffers indoor humidity fluctuations, with a moisture buffering value of 3.06 g/m² per %RH, classified as "excellent" in standardized tests measuring dynamic sorption at 20°C. However, elevated moisture contents above 15-20% by weight, as observed in prolonged exposure to 90% RH, can compromise structural integrity and promote settling in loose-fill applications, though the material's capillary structure facilitates partial recovery upon drying below these thresholds. Empirical studies indicate that water absorption in cellulose insulation increases thermal conductivity linearly, with each 1% rise in moisture content elevating it by 1.2-1.5% in loose-fill forms, reducing effective R-value by up to 15% at 10% moisture gain. Dense-packed cellulose exhibits lower liquid water permeability than fiberglass, limiting bulk water ingress while still allowing vapor exchange, as demonstrated in Alaskan field tests where it moderated relative humidity in wall cavities to around 80%, outperforming rigid foams that trapped moisture and fostered mold. This hygroscopic behavior, while increasing short-term heat transfer risks, supports overall moisture control in ventilated assemblies by absorbing excess humidity without reaching saturation under normal conditions. Vapor permeability of cellulose insulation is high, with intrinsic values around 177 × 10⁻¹² kg/(Pa·m·s) measured at 23°C and 50-94% RH, corresponding to permeance ratings typically exceeding 10 perms for thin layers and classifying it as vapor permeable (often > Class III thresholds of 1-10 perms in installed thicknesses). This diffusivity, ranging from 5 × 10⁻⁸ to 1.2 × 10⁻⁷ m²/s across 10-175% moisture contents, enables rapid drying and prevents vapor accumulation, contrasting with low-permeance foams that impede diffusion. In practice, this property enhances durability in humid climates by allowing bidirectional vapor movement, though it necessitates exterior drainage planes to manage any condensed liquid water.

Mold growth risks and mitigation

Cellulose insulation, composed primarily of ground recycled paper fibers, exhibits hygroscopic properties that enable it to absorb significant amounts of moisture—up to 15-20% of its weight under humid conditions—potentially creating environments conducive to mold growth if drying is inadequate. Prolonged exposure to water from leaks, condensation, or high humidity can elevate relative humidity within the material, fostering fungal proliferation despite chemical treatments. A 2006 peer-reviewed study on wet spray-applied cellulose insulation (WSACI) documented elevated airborne mold spore concentrations in buildings post-installation, attributing this to incomplete drying and microbial colonization within the damp matrix, with mold levels exceeding outdoor baselines by factors of 10-100 in affected spaces. Such risks are amplified in applications like attics or walls with poor ventilation, where absorbed moisture reduces thermal performance and sustains humidity above 70%, the threshold for many fungal species. Borate-based treatments, typically 10-20% by weight in commercial formulations, incorporate fungicidal compounds like boric acid that disrupt mold spore germination and mycelial growth by interfering with cellular enzymes, conferring resistance under moderate moisture exposure. These additives have demonstrated efficacy in laboratory tests, inhibiting common molds such as Aspergillus and Penicillium at concentrations as low as 1-2%, though effectiveness diminishes with saturation levels exceeding 30% moisture content. Empirical field observations indicate mold rarely develops without direct water intrusion in borate-treated dry-blown cellulose, as the material's vapor permeability allows redistribution and evaporation when ambient conditions permit. Mitigation strategies emphasize prevention over remediation: installations must occur in dry conditions with relative humidity below 50%, followed by immediate verification of building envelope integrity to exclude bulk water entry. Adequate attic ventilation (e.g., 1:150 ratio of vent area to floor area per building codes) and vapor retarders in cold climates facilitate drying, while prompt leak repairs limit exposure duration—cellulose tolerates brief dampness (e.g., from condensation) but requires removal if saturated for over 48 hours. In humid regions, hybrid systems combining cellulose with rigid foam barriers or dehumidification reduce risks, supported by monitoring protocols using moisture meters to maintain levels under 15%. Long-term, annual inspections for settling or compression, which can trap moisture, ensure sustained performance, with borate replenishment unnecessary absent degradation.

Installation Practices

Application techniques and equipment

Cellulose insulation is installed predominantly via pneumatic blowing techniques using industrial-grade machines that feed the material from a hopper, break up clumps, and propel it through hoses to application sites. Loose-fill blown-in methods suit open attics, where installers hold the hose parallel to joists at a height of 2-3 feet, allowing material to fall 4-6 feet from the nozzle for even distribution to specified depths based on R-value charts. Machines require a level surface, 20-amp 110-volt outlet, and 12-gauge extension cords, drawing 15-30 amps; hoses typically measure 3 inches in diameter and up to 100 feet long, with airflow adjusted via slide gates or valves set three-quarters open. Dense-pack application targets enclosed cavities like sidewalls to achieve settled densities of 3.5-4.0 pounds per cubic foot (PCF), minimizing air movement and settling; this requires blowing machines delivering at least 3.25 psi line pressure, often with fill tubes for single-entry holes in retrofits. For existing walls, 2-2.5 inch holes are drilled between studs, insulation injected until resistance indicates fullness (firm "mattress" feel), then probed or measured for density, with holes subsequently patched; new construction uses temporary retainers or air chutes before dry or spray application from bottom-up at 45-degree angles, leveled with scrubbers. Equipment includes drills with carbide bits, density probes, and aluminum rollers to smooth bulges. Spray-applied variants for open new walls incorporate wetting systems with 200-300 psi pumps and 2-2.5 inch semi-spiral hoses, misting insulation at manufacturer-specified fiber-to-water ratios through 2-3 inch nozzles for adhesion, followed by drying per guidelines. All methods demand pre-installation air sealing, vent baffles, and 3-inch clearances from heat sources using metal barriers, adhering to ASTM C1015 and C739 standards; personal protective equipment like N95 masks and eye protection is essential due to dust generation.

Code compliance and common pitfalls

Cellulose insulation must comply with the U.S. Consumer Product Safety Commission's Interim Safety Standard under 16 CFR Part 1209, which mandates minimum performance in corrosiveness testing, smoldering combustion resistance, and critical radiant flux of at least 0.12 W/cm² to ensure fire safety and material integrity. Additionally, it requires labeling per 16 CFR Part 1404 to warn against improper installation near heat sources, as non-compliance has historically contributed to fire incidents despite material treatments. Building codes, such as the International Residential Code (IRC) Section N1101.10.1, further stipulate that blown-in cellulose installations include permanent markers indicating initial installed thickness, settled thickness, settled R-value, installed density, and coverage area to verify long-term performance after settling. Fire code compliance hinges on borate-based fire retardants achieving a Class 1 flame spread rating of 25 or less per ASTM E84, allowing cellulose to contribute up to 15 minutes of additional fire resistance in rated assemblies without separate barriers in many jurisdictions. However, installations must avoid contact with recessed lighting fixtures or chimneys unless protected by code-approved guards, as untreated proximity can exceed smoldering thresholds. In attics and walls, dense-pack densities of at least 3.5 pounds per cubic foot (PCF) are required to minimize settling below code-specified R-values, with IRC and IECC mandating compensation for up to 20% volume loss in loose-fill applications. Common pitfalls include under-blowing to insufficient densities, resulting in excessive settling—up to 20% in attics—and subsequent voids that compromise R-value and code compliance, often undetected without post-installation verification. Failure to air-seal cavities beforehand exacerbates convective loops, reducing effective insulation and violating IECC air leakage limits, while in walls, opting for loose-fill over dense-pack leads to gaps over time. Moisture ingress during installation, particularly in humid climates without proper drying, can exceed 20% absorption capacity, fostering mold despite vapor permeability, and breaching IRC durability provisions if not mitigated by encapsulation. Dust generation from unstabilized blowing also poses inhalation risks and cleanup challenges, though mitigated by water-spray methods that enhance adhesion but require ventilation to avoid clumping. Electrical inspections often reveal non-compliance when cellulose contacts unrated fixtures, underscoring the need for licensed installers familiar with local amendments to IRC Section R302 on fireblocking.

Environmental and Lifecycle Assessment

Recycled content and resource efficiency claims

Cellulose insulation is primarily manufactured from recycled paper fibers, typically comprising 75% to 85% post-consumer waste such as newsprint, with the remainder consisting of fire-retardant and pest-resistant additives like boric acid and borax. U.S. Environmental Protection Agency guidelines for recovered materials in construction products recommend minimum recycled-content levels for cellulose insulation, while state regulations, such as those in Kentucky, mandate at least 75% post-consumer waste content for loose-fill and spray-on variants. The manufacturing process involves shredding sorted recycled paper into fibers, followed by treatment with mineral additives, which constitute approximately 15% to 25% by weight, enabling the material to meet fire safety standards without relying on virgin resources for the bulk fiber component. Proponents claim high resource efficiency due to the diversion of paper waste from landfills and reduced demand for virgin timber or petrochemicals, positioning cellulose as a circular economy option in building materials. Embodied energy analyses indicate that cellulose exhibits among the lowest values per kilogram among common insulation materials, attributed to its reliance on low-energy mechanical processing of recycled feedstock rather than energy-intensive melting or chemical synthesis required for alternatives like fiberglass or foam. For instance, lifecycle assessments report cellulose's embodied energy as 10 to 30 times lower in petrochemical inputs compared to fiberglass, though exaggerated claims of 200-fold reductions lack empirical substantiation and stem from selective comparisons excluding additive production. The addition of mined borates introduces some upstream energy and extraction impacts, yet overall, the material's production avoids the high-temperature fusion processes that dominate fiberglass manufacturing, yielding net efficiency gains in resource use. These claims are supported by the material's biodegradability and potential for end-of-life recycling or composting, though practical reuse is limited by installation in inaccessible cavities and chemical treatments that may constrain decomposition rates. Independent reviews confirm no widespread substantiation for overstated recycled purity beyond the documented 75-85% range, emphasizing that while cellulose outperforms fiberglass (20-40% recycled content) in post-consumer fiber utilization, its efficiency hinges on consistent supply of quality newsprint and effective waste sorting to minimize contaminants.

Embodied energy, emissions, and disposal realities

Cellulose insulation production involves low embodied energy, derived largely from mechanical shredding and chemical treatment of recycled paper, contrasting with energy-intensive processes for fiberglass or foam. Manufacturers report it requires about 10 times less energy than fiberglass and 64 times less than foam insulation. Life cycle assessments confirm cellulose among the lowest in embodied energy for common insulations, though precise values per kilogram vary due to recycled content (typically 75-85%) and treatment methods. Embodied carbon emissions for cellulose are contested. Producers, leveraging environmental product declarations (EPDs), claim negative global warming potential (GWP) from biogenic carbon storage in paper fibers and avoided landfill methane, estimating sequestration of -1.76 kg CO₂e per square foot at R-20 insulation. This assumes credits for recycled feedstock diverting waste from decomposition. However, analyses by fiberglass industry representatives highlight positive GWP of 0.61 kg CO₂e per functional unit (1 m² at R=1 m²K/W) in EPDs, attributing overlooked emissions to borate mining, ammonium sulfate synthesis, and transport, while disputing permanent storage. Peer-reviewed reviews underscore variability in insulation LCAs, with cellulose generally lower than fossil-based foams (1.9-3.5 kg CO₂e per functional unit for EPS) but dependent on regional energy grids and allocation methods for recycled inputs. Disposal realities diminish cellulose's lifecycle advantages, as treated material resists standard recycling due to fire retardants like boric acid, leading to landfill placement in most cases. While biodegradable, anaerobic decomposition in landfills generates methane (GWP 28-84 times CO₂ over 100-20 years), potentially offsetting up to the full sequestered carbon if uncaptured—exacerbating emissions compared to inert synthetics. Onsite recovery during retrofits allows limited reuse if uncontaminated, but this is rare; no widespread recycling infrastructure exists as of 2024, rendering end-of-life impacts a key uncertainty in net environmental benefits.

Comparisons to Alternative Insulations

Empirical performance vs. fiberglass

Cellulose insulation generally exhibits higher effective thermal resistance in practice compared to fiberglass, particularly in loose-fill applications, due to its greater density and reduced susceptibility to convective heat transfer. Laboratory analyses indicate that loose-fill cellulose maintains stable R-values without significant convection losses, whereas loose-fill fiberglass can experience 35-50% reductions in effective R-value under large temperature differentials (e.g., 32°F or more) caused by natural convection loops, as evidenced by infrared imaging and numerical modeling of attic assemblies. Installed R-values for blown-in cellulose typically range from 3.2 to 3.8 per inch, outperforming average fiberglass values of 2.2 to 3.2 per inch, with real-world attic tests showing cellulose achieving approximately 23% higher efficiency per inch than fiberglass batts. Blown-in cellulose demonstrates superior air leakage reduction over fiberglass batts in empirical field studies, contributing to overall energy efficiency gains. A 1979 Oregon study of 71 homes found cellulose-insulated structures had 15-20% lower air infiltration rates (average 10.6 air changes per hour at 50 Pa) compared to those with fiberglass or rockwool. Similarly, controlled attic floor simulations and retrofits showed cellulose yielding the greatest airflow reductions among insulation types, with balloon-framed homes exhibiting substantial tightness improvements post-installation. This sealing effect can lower infiltration by 30-40% relative to fiberglass, enhancing effective insulation beyond nominal R-values. In sound attenuation, cellulose outperforms fiberglass due to its denser packing, which better absorbs mid-to-high frequency noise. Demonstrations and comparative tests indicate cellulose reduces transmitted sound by up to 44% more than equivalent fiberglass thicknesses, with higher sound transmission class (STC) ratings for blocking decibels, though fiberglass may edge out in noise reduction coefficient (NRC) for absorption in some configurations. Fire performance favors fiberglass as a noncombustible material with consistent low flame spread (≤25 on ASTM E84) and minimal smoke development, serving reliably as a fire block without reliance on additives. Cellulose, being cellulosic, requires borate or ammonium sulfate treatments for retardancy but shows variable long-term efficacy, with up to 52% of aged samples failing critical radiant flux tests (ASTM C739) and real-world reports of higher fire incidence (e.g., 72% in Indiana department surveys) linked to smoldering or rekindling near heat sources like recessed lights. Durability assessments highlight trade-offs: fiberglass resists settling and degradation over decades, preserving installed thickness, while cellulose can compact 10-20% over time if under-dense, potentially eroding R-value unless installed at manufacturer-specified densities (e.g., 3.5 lbs/ft³). Proper dense-pack application mitigates this for cellulose, yielding longevity comparable to fiberglass in walls but requiring vigilance in attics.
AspectCellulose AdvantageFiberglass AdvantageKey Empirical Note
Thermal (R/inch)3.2-3.8; convection-resistantStable in battsCellulose 23% higher in attics
Air Sealing15-40% less leakageN/A in battsTighter homes in field studies
SoundBetter STC blockingHigher NRC absorptionUp to 44% more reduction
FireTreated resistanceInherently noncombustibleCellulose failures post-aging
DurabilityDense install stableNo settlingCellulose compaction risk

Trade-offs with foam and mineral wool

Cellulose insulation, typically offering an R-value of 3.2 to 3.8 per inch, provides thermal performance comparable to mineral wool (R-3.0 to 4.2 per inch) but inferior to closed-cell spray foam (R-6.0 to 7.0 per inch), necessitating greater thickness for equivalent insulation in space-limited applications like cathedral ceilings. However, cellulose's loose-fill or dense-pack forms excel in conforming to irregular cavities, potentially reducing air infiltration more effectively than rigid mineral wool batts when properly installed, though settling in loose applications can degrade long-term performance by up to 20% in vertical installations. Closed-cell foam's expansion creates a monolithic air barrier without settling risks, but its higher per-inch efficiency comes at 2-3 times the material cost of cellulose. In moisture management, cellulose's hygroscopic nature allows it to absorb up to 130% of its weight in water vapor while permitting drying cycles, which can mitigate condensation in permeable assemblies but risks mold growth if ventilation is inadequate or wetting is prolonged. Closed-cell foam acts as a vapor retarder with near-zero permeability, preventing moisture ingress but potentially trapping it within assemblies if installed on the interior side of cold climates, leading to rot in wood framing. Mineral wool, being hydrophobic and non-absorbent, resists water accumulation and mold without treatments, offering superior durability in damp conditions over cellulose, though it lacks the self-drying capacity of fibrous cellulose. Fire resistance favors mineral wool, which remains non-combustible up to 2,000°F and does not contribute to flame spread, outperforming cellulose's borate-treated Class I rating that can still smolder under sustained ignition. Closed-cell foam ignites above 700°F and releases toxic fumes, requiring intumescent coatings for code compliance in exposed areas, whereas cellulose's organic base burns more readily once treatments degrade from moisture or heat exposure. These differences influence selection: mineral wool suits fire-prone zones like garages, while foam's flammability limits unconditioned spaces without barriers.
PropertyCellulose InsulationClosed-Cell Spray FoamMineral Wool
R-value per inch3.2–3.86.0–7.03.0–4.2
Moisture BehaviorAbsorbs/releases vapor; drying-dependentImpermeable; traps if misappliedHydrophobic; non-absorbent
Fire RatingClass I (smolders possible)Ignites ~700°F; toxic smokeNon-combustible to 2,000°F
Settling RiskModerate in loose-fillNone (expands)None
Sound AbsorptionGoodModerateExcellent
Cellulose's advantages lie in lower embodied energy and recyclability compared to foam's high-global-warming-potential blowing agents, yet mineral wool's longevity offsets cellulose's potential degradation from settling or borate leaching in humid environments. Empirical field studies indicate cellulose achieves 10-15% better air sealing than mineral wool in retrofits via dense-packing, but foam's seamless application yields the lowest infiltration rates overall, albeit with higher upfront costs averaging $1.50–$3.00 per square foot versus cellulose's $0.60–$1.20. Trade-offs thus hinge on priorities: cellulose balances cost and permeability for ventilated assemblies, foam prioritizes barrier performance at premium expense, and mineral wool emphasizes durability and safety where fire or moisture risks dominate.

Economic and Practical Evaluation

Cost-benefit analysis over product lifecycle

Cellulose insulation exhibits a favorable cost-benefit profile over its product lifecycle, primarily driven by competitive initial costs relative to performance gains and substantial long-term energy savings. Installed costs for blown-in cellulose typically range from $1.50 to $2.50 per square foot, encompassing material and labor for attic or wall applications, with variations based on density requirements and regional labor rates as of 2025. This positions it comparably to fiberglass alternatives, which average $1.00 to $2.00 per square foot installed, though cellulose's higher density-packed R-value (3.1–3.7 per inch versus 2.2–2.7 for loose-fill fiberglass) enables equivalent or superior thermal performance with potentially less volume in retrofits. During the operational phase, spanning 30–50 years or more, cellulose delivers empirical energy cost reductions of 15–30% on heating and cooling bills in existing structures, attributable to its air-sealing properties and resistance to convection currents, which minimize heat loss more effectively than fiberglass in unsealed cavities. Payback periods for these savings average 2–5 years in moderate climates, accelerating in colder regions where heating demands dominate, with lifecycle analyses confirming positive net present value through reduced utility expenditures that offset upfront investments. A 2021 Swedish case study on residential buildings found cellulose's total lifecycle costs nearly identical to glass wool while yielding marginally lower environmental impacts, underscoring its economic viability without premium pricing. Maintenance demands are minimal, with borate-treated cellulose resisting pests, mold, and fire without routine interventions, unlike fiberglass which may require periodic checks for moisture-induced degradation. End-of-life disposal incurs negligible costs, as the material—derived from recycled paper—is biodegradable and often landfilled at standard waste fees or repurposed, avoiding the recycling complexities of synthetics. Overall, U.S. Department of Energy assessments affirm cellulose as a cost-effective option in building codes, where it serves as a lower-cost substitute for fiberglass in achieving prescribed insulation levels, yielding sustained benefits in total ownership costs. The global cellulose insulation market was valued at approximately $4.46 billion in 2024 and is projected to reach $6.55 billion by 2031, expanding at a compound annual growth rate (CAGR) of 4.92%, driven primarily by increasing demand for sustainable building materials amid stricter energy efficiency regulations and green construction initiatives. Alternative estimates place the market at $5.5 billion in 2025, growing to $8.7 billion by 2034, reflecting steady but modest expansion compared to the broader insulation sector, which anticipates a 6.9% CAGR from $74.69 billion in 2025 to $119.23 billion by 2032. Cellulose holds a niche position, with fiberglass dominating overall market share at around 30-35% due to its established supply chains and ease of use, while cellulose's growth is bolstered by its high recycled content (often over 80% from paper waste) appealing to eco-conscious builders. In regions like Europe, cellulose adoption leads revenue generation, supported by policies favoring bio-based materials with low embodied energy. Key trends include rising integration in retrofits and new residential constructions, where cellulose's superior air-sealing properties—reducing convective heat loss more effectively than loose-fill fiberglass—align with net-zero building goals, though its market penetration remains below 10% globally as of 2024. U.S. insulation demand favors fiberglass for its cost-effectiveness and DIY accessibility, but cellulose benefits from incentives like tax credits for energy-efficient upgrades under programs such as the Inflation Reduction Act, potentially accelerating uptake through 2030. Recent industry shifts show manufacturers reformulating products with more stable fire retardants and denser formulations to mitigate degradation, contributing to cautious optimism in bio-based segments. Adoption faces technical barriers, including settling rates of 13-20% in attics and walls if not dense-packed to at least 3.5 pounds per cubic foot, which can create air gaps and reduce long-term R-values by up to 20% without proper installation oversight. Its hygroscopic nature, while aiding moisture management in dry climates, risks mold growth and structural degradation in humid environments without vapor retarders or meticulous sealing, as empirical studies note higher failure rates in poorly ventilated assemblies. Economic hurdles include higher labor costs for blown-in application requiring specialized equipment and trained crews, contrasting with fiberglass's lower upfront pricing and simpler handling, leading many contractors to favor the latter despite cellulose's competitive material costs from recycled feedstocks. Perceptual and supply issues further impede widespread use: installers report excessive dust generation compromising air quality during application and a shift toward lower-quality recycled inputs like cardboard, diminishing performance consistency compared to earlier newspaper-based formulas. Lack of builder familiarity exacerbates risks, as improper density or ventilation can void warranties, while fiberglass's proven longevity in diverse climates reinforces its default status; overcoming these demands education on cellulose's lifecycle advantages, such as 20-30% better sound attenuation and fire resistance when stabilized, but empirical data underscores that without addressing settling and moisture empirically, adoption lags behind alternatives.

References

  1. [1]
    Insulation Materials | Department of Energy
    Cellulose insulation is made from recycled paper products, primarily newsprint, and has a very high recycled material content, generally 82% to 85%. The paper ...
  2. [2]
    [PDF] Nomination Background: Cellulose insulation (CASRN
    Cellulose insulation (CI) is thermal insulation made from recycled newspapers treated with fire retardants, and may contain boric acid, borax, or ammonium ...
  3. [3]
    [PDF] Survey of Cellulosic Insulation Materials - OSTI
    When properly applied, cellulosic insulation has excellent thermal resistance properties, is manufactured from an inexpensive and readily avail able waste ...
  4. [4]
    [PDF] Generic Cellulose - NIST Web Site
    Cellulose insulation is essentially shredded recovered wastepaper that is coated with fire retardants. The mix of these materials is provided in the ...
  5. [5]
    Understanding Insulation and R-Value - This Old House
    Cellulose insulation, made from recycled paper products, provides an R-value of approximately 3.2–3.8 per inch. This eco-friendly option can be blown into ...
  6. [6]
    Cellulose Insulation: An In-Depth Look at the Pros and Cons
    Sep 1, 1993 · Boric acid and sodium borate have the advantage of not only providing fire retardancy, but also adding mold, insect, and rodent resistance to ...
  7. [7]
    Pros And Cons Of Cellulose Insulation
    Cellulose insulation is eco-friendly, cost-effective, and energy-efficient, but susceptible to moisture damage, can settle, and requires professional ...Missing: empirical | Show results with:empirical
  8. [8]
    [PDF] Efficient Application of Boron Fire Retardant to Cellulosic Loose-Fill ...
    It provides criteria for corrosion resistance, settled density, flame-spread resistance, and smoldering resistance. It also contains requirements on labeling ...
  9. [9]
    [PDF] Cellulosic-Insulation-Product-Information-as-it-Relates-to ...
    The treatment process thoroughly integrates the fire retardant into the cellulose material to ensure complete and uniform treatment and optimum fire protection.<|separator|>
  10. [10]
    Harvesting ancient wisdom: a guide to designing with straw
    Jun 1, 2023 · Building with straw is nothing new. In fact, there are indications that straw and reed were used in construction more than 10,000 years ago.
  11. [11]
    Straw as a Building Material - First In Architecture
    ... straw or reeds to create a weather-resistant roof covering. They provide excellent insulation and have been used for centuries in traditional architecture.
  12. [12]
    History of Insulation - Shakespeare Home Improvement Co.
    Mar 23, 2022 · The vikings used mud and straw that was stuffed between wood building materials to keep drafts out and warmth from fires in. The Greeks were the ...
  13. [13]
    An Introduction to Cellulose Insulation - Tanguay Homes
    Cellulose insulation in Vermont has been around a long time. Thomas Jefferson used a form of cellulose to insulate his estate, Monticello - where construction ...
  14. [14]
    Old Types of Insulation - Homedit
    Sep 15, 2023 · Homes built in the 1800s and 1900s were often insulated with whatever was available. Sawdust and shavings mixed with borax. Horsehair, newspapers, and rags ...
  15. [15]
    Sawdust as wall insulation - NLCPR
    Dry sawdust or planer shavings properly packed in the walls and attics of buildings afford excellent heat insulation.<|separator|>
  16. [16]
    (PDF) The historical development of thermal insulation materials
    Aug 9, 2025 · Prehistoric people built shelters to protect themselves from the elements, originally using organic materials and later more durable substitutes ...
  17. [17]
    When Was Cellulose Insulation First Introduced? - WeedClub
    Jun 17, 2025 · Cellulose insulation dates back to the late 19th century, making it one of the oldest insulation materials still in use today. Initially, ...
  18. [18]
    Insulation Through the Decades
    Cellulose started to rise in popularity during this time, comprised of newspaper, cardboard, straw, cotton or sawdust. However, the early versions of it were ...
  19. [19]
    [PDF] Cellulose Insulation and Fire Resistance - Advanced Fiber Technology
    Dec 1, 2020 · The US Consumer Product Safety Commission (CPSC) established the fire safety requirements for cellulose insulation in 1978.
  20. [20]
    [PDF] Cellulose Insulation and Fire Safety
    Studies of both actual demonstration fires have shown that the dense fiber structure and fire retardants in cellulose insulation slows the spread of fire ...
  21. [21]
    [PDF] Cellulose Insulation and the International Standards & Codes (PDF)
    Cellulose insulation conforming with ASTM C1149 type 1 qualifies as a Class I or Class A interior finish as defined by all model building codes. Stabilized ...
  22. [22]
    Energy-Efficient Home Improvement Credit Insulation and Air ...
    Oct 29, 2024 · The 2021 IECC provides guidance to ensure the energy-efficient construction of new residential buildings and building retrofits.
  23. [23]
    Energy Efficient Home Improvement Credit | Internal Revenue Service
    If you make home improvements for energy efficiency, you may qualify for an annual tax credit up to $3200.Missing: cellulose | Show results with:cellulose
  24. [24]
    Manufactured Home Construction and Safety Standards
    Sep 16, 2024 · This final rule amends the Federal Manufactured Home Construction and Safety Standards (MHCSS or the Construction and Safety Standards)
  25. [25]
    Cellulose Insulation Market Report: Trends, Forecast and ... - Lucintel
    The global cellulose insulation market is expected to reach an estimated $5.2 billion by 2030 with a CAGR of 4.5% from 2024 to 2030. The major drivers for this ...Missing: shifts post-
  26. [26]
    [PDF] the carbon story of - Cellulose Insulation Manufacturers Association
    Nov 7, 2023 · Beyond reductions in emissions, it is becoming evident that carbon dioxide (CO2) removal strategies are required to meet the pathways outlined ...
  27. [27]
    Cellulose Insulation Market Size, Share, Trends, Scope & Forecast
    Rating 4.8 (43) Cellulose Insulation Market size was valued at $ 4.46 Bn in 2024 & is projected to reach $ 6.55 Bn by 2031, growing at a CAGR of 4.92% from 2024-2031.Missing: 2000 | Show results with:2000
  28. [28]
    Final Amendments: Cellulose Products Manufacturing Risk ... - EPA
    Feb 3, 2025 · EPA is finalizing minor amendments to the 2002 Cellulose Products Manufacturing National Emission Standard for Hazardous Air Pollutants (NESHAP).
  29. [29]
    Cellulose Insulation: Sustainable and High-Performance
    Mar 19, 2025 · Cellulose insulation is a loose insulation made from recycled paper, often 75-85% recycled paper fiber, and is considered "greener" than ...Missing: preparation | Show results with:preparation
  30. [30]
    Valley Insulation: How is Cellulose Insulation Made?
    Jun 22, 2018 · Cellulose insulation starts with recycled paper from your community. When you are finished with paper products in your home and toss them in the ...<|control11|><|separator|>
  31. [31]
    Recycled Cellulose Fiber Insulation Production - Makron
    In the first step of cellulose insulation production the raw material, paper, is fed evenly onto the pre-handling table from where it is moved to the conveyor.
  32. [32]
    Method of producing cellulose insulation - Appropedia
    Mar 8, 2015 · The production process of cellulose insulation starts with recycled newsprint, which is is initially shredded into strips 5 cm long. · Next, it ...How It's Made · Mother Earth News Methods · To Do
  33. [33]
    How Cellulose Insulation is Made: High Performance Eco-Friendly ...
    Oct 30, 2023 · The drying process also helps activate the fire retardant and pest deterrent properties, enhancing the insulation's overall performance.
  34. [34]
    Combatting Combustion: Borates in Cellulose Insulation - U.S. Borax
    Apr 18, 2023 · A primary reason is that borates improve cellulose insulation's central function: Reducing heat loss. However, it was borates' ability to resist ...
  35. [35]
    How Does Borate in Cellulose Insulation Prevent Pests?
    Dec 6, 2023 · The borate used in the insulation manufacturing process can do both. Borate, when added to cellulose insulation properly, can repel insects.
  36. [36]
    [PDF] A5.1 Use of Borates in Adhesives, Paper and Pressed Panels
    Jan 15, 2014 · In cellulose insulation, for cellulose fibres fire resistance, 12% boric acid is added while for mould and fungus cellulose resistance, 6% borax ...
  37. [37]
    Thermochemical processing of boron-impregnated cellulose ...
    May 1, 2023 · During the industrial production process, powdered borate salt was mixed homogeneously in the cellulose material. The lightweight and ...
  38. [38]
    Types of Insulation | Department of Energy
    Loose-fill insulation can be installed in either enclosed cavities such as walls, or unenclosed spaces such as attics. Cellulose, fiberglass, and rock wool are ...<|separator|>
  39. [39]
    Guide to Cellulose Insulation | R-Value, Costs & Blow-In Benefits
    Feb 26, 2025 · With a high R-value – showing excellent thermal resistance – it keeps homes comfortable year-round while cutting energy use and lowering utility ...
  40. [40]
    Cellulose Insulation For Residential & Commercial Contractors
    Apr 3, 2025 · The R-value is determined by the depth of material installed by the contractor. The more depth, the higher the R-value. (R-value requirements ...Missing: properties | Show results with:properties
  41. [41]
    [PDF] STANDARD PRACTICES FOR INSTALLATION OF CELLULOSE ...
    Members of the Cellulose Insulation Manufacturers Association (CIMA) have developed these installation guidelines to cover the recommended methods of installing ...
  42. [42]
    [PDF] TM-INS765 Attic Card Template - Greenfiber
    MINIMUM NET WEIGHT IS 23.75 LBS. THE ABOVE COVERAGE CHART IS BASED ON A NOMINAL BAG WEIGHT OF 25.0 LBS USING A VOLUMATIC III, 3rd. GEAR AND 8" GATE.
  43. [43]
    [PDF] liFetiMe PeRFoRManCe - Insulation Institute
    virtually no signs of R-Value loss over time.1 On the other hand, cellulose loose-fill insulation can settle up to 20%2 and requires compensation for settling.
  44. [44]
    Debunking 6 Common Myths About Cellulose Insulation - Greenfiber
    Feb 23, 2023 · THE TRUTH: Cellulose insulation does not settle in sidewalls, if properly installed ... Our loose-fill cellulose insulation is not limited to new ...
  45. [45]
    All About Cellulose Insulation: A Complete Guide
    Oct 28, 2024 · With its higher R-value per inch compared to traditional materials, it creates a more effective thermal barrier. Homeowners typically see up to ...
  46. [46]
    What is Cellulose Insulation? What's it Made of and How Does it ...
    The R-Value for loose-fill cellulose is between an R-3.1 and R-3.8 per inch. There is a range here because that number can vary depending on the manufacturer.
  47. [47]
    Fiberglass vs. Cellulose Insulation - PV Heating, Cooling & Plumbing
    A given sample of cellulose insulation will provide better thermal performance than an identically sized sample of fiberglass insulation.
  48. [48]
    Cellulose vs Fiberglass Insulation: Which is Best?
    Sep 2, 2025 · In contrast, cellulose insulation is more prone to settling, which can create gaps and reduce its insulating effectiveness over time. This makes ...
  49. [49]
    [PDF] Dense Pack Cellulose Insulation - Energy OutWest
    Dense Pack Cellulose Insulation: Methods and Verification of Density. Installation of Dense Pack Cellulose. ▫ Density of cellulose must be at least 3.5 pounds.Missing: properties | Show results with:properties
  50. [50]
  51. [51]
    Cellulose vs. stabilized cellulose? - GreenBuildingAdvisor
    Jan 22, 2014 · Most of the cellulose going into walls here is stabilized cellulose ... The dense-pack method has been around for years, and as long as the ...Fiberglass or Cellulose? - GreenBuildingAdvisorBIBS fiberglass dense pack vs. cellulose dense packMore results from www.greenbuildingadvisor.com
  52. [52]
    Insulation: Stabilized Cellulose Advantages
    It's Eco-friendly, cost-effective, safe, easy to install around uneven surfaces, and even provides good sound dampening. We at EPB like to take it a step ...
  53. [53]
    What is Dense Pack Insulation & The Benefits
    R-value: It offers a high R-value ranging from R-3.5 to R-3.7 per inch. · Sealing property: Compared to fiberglass, cellulose insulation material has 38% better ...Missing: definition | Show results with:definition
  54. [54]
    BSI-043: Don't Be Dense—Cellulose and Dense-Pack Insulation
    Dec 13, 2010 · Dense pack cellulose and dense pack fiberglass are not air barrier materials, and they do not result in air barrier assemblies. Although, with ...
  55. [55]
    Pros And Cons Of Dense Pack Cellulose - South Central Services
    Nov 15, 2024 · Compared to other products, such as batt or spray foam, dense pack could take up to 2 to 3 times longer to install.
  56. [56]
    Benefits of Dense-packed Cellulose Insulation Versus Batts or Other ...
    Jul 12, 2024 · It has higher thermal conductivity, is environmentally friendly, provides good sound insulation, helps prevent fires, saves money over time, ...Missing: definition | Show results with:definition
  57. [57]
    Insulating With Damp-Spray Cellulose - GreenBuildingAdvisor
    Mar 26, 2015 · The advantage to damp spray vs. dense pack is primarily cost- it's slightly less material, and it installs more quickly for lower labor costs.Missing: process | Show results with:process
  58. [58]
    Cellulose Insulation - A Smart Choice - UMass Amherst
    The Cellulose Insulation Manufacturers Association (CIMA) claims that insulating a 1500 ft2 house with cellulose will recycle as much newspaper as an ...<|control11|><|separator|>
  59. [59]
    The properties of cellulose insulation applied via the wet spray ...
    The disadvantages associated with this method, however, are mainly due to improper installation of CFI while it is sprayed with water. If too much water is ...
  60. [60]
    Who Are the Best Cellulose Insulation Manufacturers?
    It is low dust with R-Values that vary between R-11 and R-60. Applegate Loose-Fill Cellulose Insulation is often dense packed in new and existing homes and ...
  61. [61]
    Greenfiber Low Dust Cellulose Blown-In Insulation 19 lbs. INS541LD
    ... Insulation Features. Fire Block Rated, Formaldehyde Free, Soundproofing Insulation, Structural. Insulation Location. 2x4 Wall, 2x6 Wall, Attic, Ceiling ...
  62. [62]
    What is the R-value of Cellulose Fiber? | Star Spray Foam
    Oct 31, 2023 · Cellulose insulation has an R-value of about 3.5 per inch of thickness, generally ranging from R-3.2 to R-3.8 per inch.
  63. [63]
    Fiberglass vs. Cellulose: Comparing the Facts - Nu-Wool
    Regarding thermal performance, cellulose insulation demonstrates superior efficiency with an R-value ranging from 3.2 to 3.8 per inch, compared to fiberglass, ...Missing: conductivity | Show results with:conductivity
  64. [64]
    Advantages of Cellulose Insulation in Northern VT - Tanguay Homes
    The thermal conductivity of loose-fill cellulose insulation is approximately 40 mW/m·K (an R-value of 3.8 per inch) which is about the same as or slightly ...
  65. [65]
    How To Calculate R-Value Of Settled Cellulose Attic Insulation
    R-values for cellulose insulation are based on settled thickness and bag count, not installed thickness. A reasonable R-factor is 3.8.Missing: wet | Show results with:wet
  66. [66]
    None
    ### Summary of Thermal Performance Analysis of Fiberglass vs. Cellulose Attic Insulations
  67. [67]
    How Much Does Cellulose Insulation Settle? | Reinsulation
    Jan 3, 2018 · Cellulose insulation can settle by as much as 20 percent, depending on how it is installed. This could leave gaps in a wall as the insulation compacts ...
  68. [68]
    Compressed Insulation R values - InterNACHI®️ Forum
    Nov 29, 2012 · The manufacturers of cellulose list the R-Value of their product “after settlement” which is about 10 to 20 percent. · The density after ...
  69. [69]
    Loose-Fill Insulation - Building America Solution Center
    The settled density range for loose-fill cellulose is 1.5 to 2.0 lb/ft3 (36 to 24 kg/m3) and its settled R-value per inch is from 3.2 to 3.8 (0.222 to 0.2636 ...
  70. [70]
    Cellulose Insulation - an overview | ScienceDirect Topics
    The first use of cellulose fibre as an insulation material can be traced back to 1919 in Canada [40], but it was until the 1950s that commercial cellulose ...
  71. [71]
    Cellulose and stone wool in terms of moisture properties resulting ...
    This study investigates the moisture performance of cellulose insulation ... D6030 – Impact of moisture on long term performance of insulating products.
  72. [72]
    [PDF] Wet-Spray Cellulose Insulation Systems
    These studies confirm that moisture escape from a wall cavity is often a slow process. Even in the dry Alberta cli- mate, five months is a long drying time.
  73. [73]
    [PDF] Cellulose Insulation Moisture Performance
    This report presents preliminary findings related to the moisture performance of wall systems using dense-pack cellulose insulation. Background. Traditional ...
  74. [74]
    What is the R-value of blown in cellulose at different densities?
    Jan 30, 2016 · Loose-fill cellulose is R-3.8 per inch and dense-packed cellulose is about 3.65 per inch at a density of 3 1/2 lbs. per cubic foot. Denser than that and the R- ...
  75. [75]
    How Long Does Insulation Last? | Lifespan & Durability Study
    Mar 25, 2025 · Proper material choice, quality, environment, installation, and maintenance all play a role in long-term performance.
  76. [76]
    Research on Thermal Insulation Performance and Impact on Indoor ...
    Other studies have shown that the thermal conductivity of cellulose thermal insulation is influenced by moisture content during use, with thermal conductivity ...Missing: empirical | Show results with:empirical
  77. [77]
    Fire retardancy of natural fibers: Mechanisms, treatments, and ...
    One widely studied chemical mechanism is char formation, where phosphorus-based flame retardants catalyze dehydration reactions in cellulose, promoting the ...
  78. [78]
    Permanency of boric acid used as a fire retardant in cellulosic ...
    The rate of loss of the chemical fire retardant, boric acid, from loose-fill cellulosic insulation due to sublimation has been determined.
  79. [79]
    Firefighters Guide For Cellulose Insulation Building Fires
    The fire retardant in cellulose insulation suppresses flaming combustion and the dense fiber structure of the material resists passage of fire and hot gases.Missing: mechanisms | Show results with:mechanisms
  80. [80]
    Cellulose Insulation - Borates Plus
    The use of borates in cellulose insulation greatly increases the fire retardancy of the product. Because borates are incombustible and will melt
  81. [81]
    Is Cellulose Insulation Flammable? Fire Safety Guide
    Nov 11, 2024 · Fire-Retardant Treatment. Cellulose insulation undergoes comprehensive treatment with borate-based chemicals during manufacturing. The ...
  82. [82]
    Mechanism and kinetics of thermal degradation of insulating ...
    Jul 25, 2018 · Fire retardants could catalyze the dehydration of cellulosic thermal insulating materials at a lower temperature and facilitate the generation ...<|separator|>
  83. [83]
    16 CFR Part 1209 -- Interim Safety Standard for Cellulose Insulation
    The settled density of lose fill insulation must be determined before the corrosiveness test (§ 1209.5) and the smoldering combustion test (§ 1209.7) can be ...
  84. [84]
    Technical Support for the Consumer Product Safety Commission ...
    Mar 2, 1981 · The attic floor radiant panel test (AFRPT) and smoldering combustion test are two fire performance tests required by the Consumer Product Safety ...<|separator|>
  85. [85]
    [PDF] 30 Fire Safety BI472 v7 - Insulation Institute
    These regulations mandate that cellulose insulation pass certain fire test procedures. In addition, the CPSC requires labeling on cellulose insulation to inform.
  86. [86]
    [PDF] Toxicity Study Report on the Atmospheric Characterization, Particle ...
    This report covers the atmospheric characterization, particle size, chemical composition, and workplace exposure assessment of cellulose insulation.
  87. [87]
    [PDF] Insulation And Your Home: Health Considerations - CT.gov
    Ammonium sulfate and boric acid are fire retardants commonly found in cellulose insulation. Occassionally, the ammonium sulfate can off-gas and produce an odor.
  88. [88]
    [PDF] HHE Report No. HETA-2000-0332-2827, NIOSH Exposure ...
    Some substances have recommended STEL or ceiling values which are intended to supplement the TWA where there are recognized toxic effects from higher exposures.
  89. [89]
    Blown-In-Cellulose Insulation Test Results - Healthy Building Science
    Aug 21, 2013 · Blown-in-cellulose insulation had 101 µg/m³ total VOCs and 12.7 µg/m³ formaldehyde, which is 20% of the GREENGUARD limit of 61.4 µg/m³. It is a ...
  90. [90]
    Volatile Organic Compound Composition and Emissions in a ...
    May 2, 2024 · In this study, attic VOC concentrations and emissions were assessed in a normally-occupied single-family residence in Oakland, California over 10 weeks during ...
  91. [91]
    Sound absorption properties of unbleached cellulose loose-fill ...
    Different samples of a single layer of loose-fill cellulose insulation with different thicknesses were tested to measure their sound absorption properties.Missing: attenuation scientific
  92. [92]
    Nu-Wool Blown-In Soundproof Insulation for Noise Reduction
    Rooms are noticeably quieter with Nu-Wool's blown-in soundproof insulation, which deadens the transfer of sound from one room to another.
  93. [93]
    The Best Insulation Types for Soundproofing - Ecotelligent Homes
    Cellulose insulation has a 39 STC rating. Interested in improving your home's insulation? Certain forms of insulation can help provide noise reduction, but no ...
  94. [94]
    The Best Type of Insulation for Soundproofing Your Home
    Jan 10, 2022 · Cellulose insulation has an STC rating of 44 and an NRC of 0.80. All on its own, it dampens sound enough to create a quiet, Zen-inducing home ...<|separator|>
  95. [95]
    Why Cellulose
    Sep 9, 2022 · Cellulose insulation may be used to achieve STC ratings as high as 70 depending on the wall or partition assembly where the product is ...
  96. [96]
    [PDF] for sound attention, cellulose insulation outperforms all ... - Greenfiber
    Apr 9, 2025 · Cellulose installed within a 2x4 wall cavity adds approximately 5 dB of sound reduction, while cellulose in a 2x6 wall cavity adds about 9 dB ...
  97. [97]
    [PDF] STC Ratings of wall assemblies INSULATED with Cellulose Spray ...
    STC Ratings of wall assemblies INSULATED with Cellulose Spray. Testing done with full scale assemblies by National Research Council Canada.
  98. [98]
    [PDF] Greenfiber Do-It Yourself Guide
    Bag Weight: 19.05 lbs. Attic Density Range: 1.32-1.65 lbs/cu ft. Wall Density: 3.5 lbs/cu/ft.
  99. [99]
    Dense-Pack Cellulose Coverage Chart - Fine Homebuilding
    In order for cellulose to be self-supporting, it has to be installed at a 3-1/2-lb.- to 4-lb.-per-cu.-ft. density. You can double check to see if your work ...
  100. [100]
    Cellulose Insulation vs Fiberglass Insulation - Diffen
    Weight: Cellulose insulation weighs more than fiberglass for the same R-value. So building structures should be inspected for signs of weakness before choosing ...
  101. [101]
    Blown fiberglass or cellulose? : r/Insulation - Reddit
    Aug 11, 2023 · Blown fiberglass and cellulose both have almost the same R-value; about R-3 per inch. Fiberglass weighs about 1/3 of the cellulose, if that ...Contractor is recommending fiberglass over cellulose. What do you ...Weight concerns of blow in cellulose? : r/HomeImprovement - RedditMore results from www.reddit.com
  102. [102]
  103. [103]
    Facts About Cellulose Insulation Settling - Fiberlite Technologies
    Jan 31, 2023 · Back in the early 1970s, the entire insulation industry, including fiberglass, was loosely regulated. This changed in the late 1970s and ...
  104. [104]
    How much cellulose is too much? - GreenBuildingAdvisor
    May 23, 2024 · Cellulose is dense-packed to somewhere between 3.0 and 4.2 lbs/ft³. At the lower end of that range, it can settle. At the upper end it can't, ...Cellulose insulation settling - GreenBuildingAdvisorCan cellulose be too fluffy? - GreenBuildingAdvisorMore results from www.greenbuildingadvisor.com
  105. [105]
    Long-term settlement behavior of loose-fill cellulose insulation under ...
    Aug 6, 2025 · Strongest settling was observed in outdoor climate, followed by dynamic vibration at a clearly lower level while least settling occurred under ...
  106. [106]
    Weight of Cellulose in Attic - GreenBuildingAdvisor
    Feb 16, 2021 · I was looking online at cellulose fact sheet and it says the minimal weight per sq ft is 1.16 @ r-38. I think I would be okay with 1.16 psf but ...
  107. [107]
    Weight of cellulose to attic - GreenBuildingAdvisor
    Nov 11, 2019 · #3. Open blown cellulose is almost always at or under 2lbs per cubic foot ... Some installers intentionally shoot for 2lbs per cubic foot nominal ...How many cubic feet in one bag of cellulose insulation?How to calculate how much cellulose for a dense-packed wall?More results from www.greenbuildingadvisor.com
  108. [108]
    [PDF] A review on the properties of cellulose fibre insulation - HAL
    Jan 24, 2020 · An increase in 1% of moisture con tent can lead to an average increase of 1.2%e1.5% in l values for loose fill CFI. Even when high moisture ...
  109. [109]
    [PDF] The properties of cellulose insulation applied via the wet ... - HAL
    The influence of adsorbed humidity on thermal conductivity on loose fill cellulose fibres has been studied. A linear relation between moisture content and ...Missing: behavior | Show results with:behavior
  110. [110]
    Vapor Barriers or Vapor Retarders - Department of Energy
    Vapor retarders reduce water vapor movement, and are measured in perms. Examples include glass, polyethylene, and polystyrene. They are used in basements, ...
  111. [111]
    Cellulose Insulation Safety: What You Need to Know — Rmax
    Dec 19, 2024 · Although cellulose insulation is treated with fire retardants, it is not inherently fire-resistant. Studies show that the protective treatments ...Why Polyiso Insulation Is A... · Polyiso's Exceptional... · Applications Of Rmax Polyiso...
  112. [112]
    Mold infestation of wet spray-applied cellulose insulation - PubMed
    Results of this study suggest that WSACI has the potential to cause elevated airborne mold levels in buildings where it has been applied and pose significant ...Missing: studies | Show results with:studies
  113. [113]
    Mold & Home Insulation: Here's What You Need to Know - Indiana ...
    Apr 15, 2024 · Mold rarely grows in cellulose insulation without direct water damage because of boric acid used as a fire retardant in the material. Boric ...
  114. [114]
    Boron in insulation - U.S. Borax
    Borates are used to produce two types of insulation: Fiberglass insulation and cellulose insulation. Benefits of borate-based insulation. In fiberglass and ...
  115. [115]
    Does Cellulose Insulation Offer Enough Protection Against Mould ...
    Sep 13, 2024 · With its borate treatment and moisture management capabilities, cellulose insulation provides significant resistance against mould growth.
  116. [116]
    How to Install Cellulose Insulation - GreenBuildingAdvisor
    Mar 11, 2011 · Insulation expert Bill Hulstrunk provides detailed instructions for blowing loose-fill cellulose on attic floors and dense-packing walls.
  117. [117]
    How to Install Cellulose Insulation | Greenfiber
    Learn how to install Greenfiber cellulose insulation. Determine your project needs and see step by step instructions with this helpful video.
  118. [118]
    720.6 Cellulose Loose-Fill Insulation - UpCodes
    Cellulose loose-fill insulation shall comply with CPSC 16 CFR Part 1209 and CPSC 16 CFR Part 1404. Each package of such insulating material shall be clearly ...
  119. [119]
    2021 International Residential Code (IRC) - N1101.10.1 (R303.1.1 ...
    For blown-in or sprayed fiberglass and cellulose insulation, the initial installed thickness, settled thickness, settled R-value, installed density, coverage ...
  120. [120]
    16 CFR § 1404.2 - Background. - Legal Information Institute
    Presently available information indicates that fires may occur where cellulose insulation is improperly installed even though the cellulose insulation complies ...Missing: compliance | Show results with:compliance
  121. [121]
    How Install Dense-Pack Cellulose Insulation Like a Pro
    Nov 17, 2017 · Learn how to install dense-pack cellulose insulation to stop air leaks and help manage moisture; get pro tips on tools, techniques, ...
  122. [122]
    7 Things Homeowners Should Know About Cellulose Insulation
    Dec 31, 2024 · Blown-in cellulose insulation can be hazardous if not installed properly. While there are many great benefits to installing cellulose insulation ...
  123. [123]
    Comprehensive Procurement Guidelines for Construction Products
    Aug 16, 2025 · EPA's Recovered Materials Advisory Notice (RMAN) recommends recycled-content levels for purchasing building insulation as shown in the table ...
  124. [124]
    Title 200 Chapter 5 Regulation 330 • Kentucky Administrative ...
    Cellulose loose-fill and spray-on shall contain seventy-five (75) percent postconsumer waste.<|separator|>
  125. [125]
    How does cellulose insulation affect the environment? - Greenfiber
    Apr 20, 2023 · SANCTUARY® by Greenfiber is made in electric-powered plants using low-energy manufacturing processes. Fire retardants used in the insulation are ...
  126. [126]
    A review on the properties of cellulose fibre insulation - ScienceDirect
    Feb 1, 2016 · It offers good thermal properties and has a low embodied energy. However due to lack of expertise in its application and properties, cellulose ...
  127. [127]
    Embodied energy and carbon of building insulating materials
    The energy and environmental impacts attributed to buildings insulation materials can be distinguished in direct embodied burdens and avoided impacts due to ...
  128. [128]
    Why Cellulose Insulation Fits Well With Earth Day
    Cellulose Insulation takes about 64 times less embodied energy to produce than Foam Insulation and 10 times less than fiberglass insulation. 3. Provides ...
  129. [129]
    Environmental Impacts of Cellulose Insulation - Ecotelligent Homes
    This article will be explaining what cellulose insulation is, how it is impacting the environment and how it compares to other insulation methods and materials.
  130. [130]
    [PDF] Setting the Record Straight: Insulation and Low Carbon Buildings
    Oct 24, 2024 · This guide aims to correct misleading carbon claims made by some cellulose and wood fiber insulation manufacturers.
  131. [131]
    Insulation Disposal: How to Get Rid of It - Dumpsters.com
    Generally speaking, you can recycle insulation. However, it should be noted from the start that cellulose and foam board insulation can't be recycled.
  132. [132]
    Can Home Insulation Be Reused or Recycled? - REenergizeCO
    Cellulose insulation, meanwhile, cannot be recycled. That's because of the fire-retardant materials used in cellulose. So while cellulose is environmentally ...
  133. [133]
    Cellulose or Fiberglass Insulation, Which is Better for Your Attic?
    May 21, 2024 · Blown-in cellulose has an R-value of about 3.5 per inch, making it approximately 23% more effective per inch than fiberglass batts. In cold ...
  134. [134]
    [PDF] Research Shows Increased Building Tightness With Cellulose ...
    Dec 12, 1986 · In other words, houses insulated with cellulose insulation are tighter than houses built with fiberglass batts. The second claim is that unlike.
  135. [135]
    The Importance of Effective R-Value in Insulation - Nu-Wool
    Feb 18, 2025 · Studies have shown that cellulose can reduce air infiltration by up to 30-40% compared to fiberglass.
  136. [136]
    Fiberglass vs. Cellulose Insulation: Which Works for Florida Homes?
    Tests show it reduces sound by up to 44% more than fiberglass insulation. However, fiberglass still provides solid soundproofing for Miami or Tampa homes ...<|separator|>
  137. [137]
    Blown in Attic Insulation: Cellulose vs Fiberglass
    Jun 19, 2023 · Sound Insulation: Cellulose also provides excellent sound insulation due to its density, making your home quieter. Fits Irregular Shapes: As a ...
  138. [138]
    Fiberglass versus Cellulose - GreenBuildingAdvisor
    Mar 5, 2012 · Fiberglass batts are inexpensive and widely available, but dense-packed cellulose does a better job of reducing air leakage.
  139. [139]
    Insulation Types | Fiberglass, Mineral Wool, Spray Foam
    Insulation types include fiberglass insulation, mineral wool insulation, cellulose insulation, and spray foam insulation. Learn more about the options here.
  140. [140]
    Spray Foam vs. Fiberglass vs. Rock Wool vs. Blown-In Cellulose
    Apr 23, 2025 · Cellulose has good thermal properties and is more effective than fiberglass at filling irregular spaces. However, it can settle over time, ...Missing: empirical data
  141. [141]
    All About Insulation for Your Home - This Old House
    While cellulose and fiberglass insulation perform similarly, cellulose is better at absorbing and releasing moisture without degrading and settling like ...
  142. [142]
    Insulation Pros and Cons: Mineral Wool vs. Fiberglass vs. Cellulose
    Sep 25, 2019 · It has a higher R-value per inch compared to fiberglass, about a 22-37% higher R-value. It contains 70% recycled material, making it a greener ...
  143. [143]
    Insulation Types | Commercial, Thermal, Fire, Sustainability
    Fiber glass insulation and mineral wool insulation – are naturally non-combustible · Spray foam insulation – Spray foam insulation will ignite at 700°F.Thermal Performance · Sound Insulation For... · Health Impacts
  144. [144]
    A quantitative comparison on the use of thermal insulation materials ...
    Nov 1, 2023 · This research proposes an inverse decision-making approach to investigate on the reasons behind the use of some thermal insulation materials in three countries.
  145. [145]
    Choosing Between Mineral Wool and Cellulose
    Nov 12, 2020 · Mineral wool insulates slightly better and is even more fire-resistant than cellulose. In large cavities it may install easier than cellulose.
  146. [146]
    Blown In Insulation Cost: A Comprehensive Guide For Homeowners ...
    Feb 12, 2025 · 2. Cellulose Blown-In Insulation · Material cost: $0.70 to $1.50 per square foot · Installed cost (including labor): $1.50 to $2.50 per square ...
  147. [147]
    Cost to Install Blown-In Cellulose Insulation - Homewyse
    The basic cost to Install Blown-In Cellulose Insulation is $1.64 - $2.87 per square foot in October 2025, but can vary significantly with site conditions ...
  148. [148]
    How Much Does Blown-In Insulation Cost to Install? - Bob Vila
    Jul 20, 2022 · Fiberglass is the least expensive option and runs about $0.50 to $1.10 per square foot, while cellulose comes in around $0.60 to $2.30 per ...
  149. [149]
    Cellulose vs Fiberglass Insulation: Which Is the Best? | Angi
    Oct 31, 2023 · Overall, cellulose has a higher R-value than fiberglass. · Cellulose is a more expensive option, running $0.60–$2.30 per square foot. · Fiberglass ...Missing: total ownership
  150. [150]
    How Much Money Will I Really Save by Upgrading my Insulation?
    Apr 28, 2025 · Upgrading your insulation in Connecticut can save 15–30% on heating and cooling bills—often paying for itself in just 2 to 5 years.
  151. [151]
    Retrofit Home Insulation Payback Period: Optimizing Long-Term ...
    The typical payback period for upgrading home insulation is between 2 and 10 years, depending on factors such as insulation type and climate zone.
  152. [152]
    (PDF) Life Cycle Environmental and Cost Analysis of Building ...
    Aug 9, 2025 · Furthermore, the analysis shows that cellulose insulation has slightly lower GWP-impact and nearly the same cost as the glass wool alternative.
  153. [153]
    [PDF] National Cost Effectiveness of the Residential Provisions of the 2021 ...
    DOE has an established methodology for determining the energy savings and cost ... cellulose insulation would be used as a lower cost alternative to fiberglass.
  154. [154]
    Cellulose Insulation Market to reach USD 8.7 bn by 2034
    In stock Rating 5.0 (200) Cellulose Insulation Market size is expected to be valued at USD 5.5 bn in 2025, and it is further anticipated to reach a market value of USD 8.7 bn by 2034 ...Missing: 2000 | Show results with:2000
  155. [155]
    Insulation Market 2025–2032: Rapid Growth Fueled by Green ...
    Jul 10, 2025 · The market is projected to grow from USD 74.69 billion in 2025 to USD 119.23 billion by 2032, at a CAGR of 6.9 percent.
  156. [156]
    Insulation Market Size, Share, Trends & Forecast, 2025-2032
    Building & construction is expected to contribute the 36.1% share of the global insulation market in 2025, accounting for 37.2% share in 2024.Insulation Market Size And... · Market Concentration And... · Regional Insights
  157. [157]
    Global Building Insulation Market Size, Trends, Share 2032
    Rating 4.5 · Review by Katelin KharratiFiberglass dominated the market in 2022 with a market share of 35% and is expected to keep its dominance during the forecast period 2024-2032.
  158. [158]
    Cellulose - Building Thermal Insulation Market Statistics
    The market is expected to grow at a CAGR (2025 - 2030) of 5.5% by 2030. In terms of region, Europe was the largest revenue generating market in 2024.
  159. [159]
    US Insulation - The Freedonia Group
    Demand for insulation in the US is forecast to increase 1.9% annually to 10.4 billion pounds in 2025 from a high 2020 base.Missing: drivers | Show results with:drivers
  160. [160]
    Greenfiber: Decades Ahead of the Cellulose Insulation Craze ...
    Feb 12, 2025 · Discover how Greenfiber's decades of commitment to sustainability is driving the future of insulation in this exclusive interview with CEO Tom VanAlstine.
  161. [161]
    How Long Does Blown-In Cellulose Insulation Last?
    Apr 21, 2021 · In fact, cellulose has the highest rate of settling rates, ranging from 13 to 20% after installation. This settling continues for weeks, months ...
  162. [162]
    Cellulose Insulation Problems: 5 Issues that Could Lead to Disaster
    Cellulose insulation problems include settling, air gaps, water damage, dust, and drifting due to vents, causing uninsulated areas.<|separator|>
  163. [163]
    5 Problems with Cellulose Insulation
    Jun 13, 2024 · These chemicals can be harmful to your health, and in humid environments like Houston, they can even dilute into the air you breathe. While ...
  164. [164]
    Why do most contractors prefer fiberglass over cellulose? And some ...
    Apr 24, 2022 · It seems like cellulose is better in many aspects but I wonder why contractors in my area hate it. The dust issue in cellulose installation is messy enough to ...<|control11|><|separator|>
  165. [165]
    Why is Cellulose Insulation So Cheap? - Star Spray Foam
    Nov 3, 2023 · Cellulose insulation is cheap due to abundant recycled paper, efficient manufacturing, competitive pricing, and meeting insulation standards ...
  166. [166]
    Why are insulation contractors in my area no longer offering cellulose?
    Mar 19, 2025 · The quality of cellulose insulation has declined. There is now much less newspaper and more cardboard and "lower quality" cellulose available in dense pack ...Missing: adoption | Show results with:adoption