Fact-checked by Grok 2 weeks ago

External Active Thermal Control System

The External Active Thermal Control System (EATCS) is a vital subsystem of the (ISS) designed to reject waste heat generated by U.S. and international partner pressurized modules, as well as power distribution electronics on the station's segments, to the of space. It operates as two independent, mechanically pumped single-phase loops—Loop A on the starboard (S1) and Loop B on the (P1) —each capable of handling up to 35 kW of heat, for a total system capacity of 70 kW. The EATCS ensures stable thermal conditions for critical ISS components by collecting heat from internal water-based cooling loops via interface heat exchangers and transporting it externally for dissipation, preventing overheating that could compromise mission operations and equipment longevity. Activated during mission in December 2006, it replaced the temporary Early External Active Thermal Control System (EEATCS), which provided only 14 kW of , thereby enabling full operational heat rejection for the expanded station. serves as the working fluid due to its excellent properties and low freezing point, with each maintaining supply temperatures around 37°F ± 2°F to optimize performance across varying orbital conditions. Key components of the EATCS include five interface heat exchangers per loop, located in Node 2, the U.S. Destiny Laboratory, and Node 3, which transfer heat from the internal active thermal control system without mixing fluids. Cold plates, numbering four per loop, directly cool power electronics such as Main Bus Switching Units (MBSUs) and Direct Current-to-Direct Current Converter Units (DDCUs) by absorbing 495 W and 694 W respectively per unit. The system's radiators consist of two sets of rotating wings—each with three Orbital Replacement Units (ORUs) and eight panels—mounted on the S1 and P1 trusses to radiate heat efficiently, supported by pump modules that circulate ammonia at rates of 8,200 to 8,900 lb/hr and ammonia tank assemblies holding 640 lb of fluid for system makeup. Thermal radiator rotary joints allow the radiators to rotate up to ±105 degrees for optimal solar exposure and eclipse management, ensuring reliable operation in the ISS's low Earth orbit environment.

Overview

Purpose and Functionality

The External Active Thermal Control System (EATCS) is an active thermal management subsystem on the (ISS) that employs mechanically pumped fluid loops to collect, transport, and reject excess heat generated by onboard modules and equipment, particularly when passive thermal controls prove inadequate for maintaining operational temperatures. This system serves as the primary permanent mechanism for active heat rejection, ensuring the station's habitable and functional environments remain within safe thermal limits despite varying heat loads from , experiments, and crew activities. Its core function is to sustain across the ISS by rejecting up to 70 kW of to the vacuum of space through , with each of the two parallel loops capable of handling 35 kW. Unlike passive thermal control methods, such as (MLI) and heat pipes, which passively manage baseline heat loads through radiation reflection and conduction without moving parts or power input, the EATCS actively circulates fluid to address peak thermal demands that exceed passive capabilities. The EATCS specifically supports the thermal needs of U.S. pressurized modules, including the Destiny Laboratory, Node 2, and Node 3, as well as the Japanese Experiment Module (JEM), the Orbital Facility (COF), and external power distribution electronics on the S0, S1, and P1 trusses of the station's . Within the broader ISS thermal control architecture, it interfaces with internal systems to provide the necessary for the On-orbit Segment and its international partners.

Integration with ISS Thermal Control

The External Active Thermal Control System (EATCS) serves as the primary active heat rejection component within the International Space Station's (ISS) comprehensive Thermal Control System (TCS), working in tandem with the Internal Active Thermal Control System (IATCS) for heat acquisition inside pressurized modules and the Passive Thermal Control System (PTCS) for supplementary , coatings, and radiators that minimize environmental heat loads. By transporting and rejecting excess heat generated by crew, equipment, and experiments to via ammonia loops, EATCS ensures stable thermal conditions across the U.S. Orbital Segment () and international partner contributions, handling up to 70 kW of total capacity while the IATCS manages internal distribution using water loops and PTCS provides non-mechanical support. Integration occurs primarily through ten Interface Heat Exchangers (IFHXs) that connect EATCS loops to IATCS loops in key modules, including the U.S. Destiny laboratory, European Node-2 (Harmony), and Node-3 (Tranquility), enabling efficient from low-temperature (around 4°C) and moderate-temperature (around 17°C) internal circuits. These counterflow exchangers, each featuring layered plates for and , were sequentially activated during ISS missions, such as 12A.1 for Destiny and 20A for Node-3, to support operations in the U.S., European , and Japanese Kibo modules without relying on the Russian segment's separate systems. EATCS extends cooling to external power and avionics equipment via cold plates mounted on truss segments like S0, S1, and P1, directly managing heat from Direct Current-to-Direct Current Conversion Units (DDCUs, dissipating about 694 W each) and Sequential Shunt Units (SSUs), which regulate solar array output and are integral to the photovoltaic system. This setup rejects heat from these external electrical systems—critical for ISS power distribution—through the same network that serves internal loads, preventing overheating in exposure. To enhance reliability, EATCS employs dual independent loops (Loop A on the S1 and Loop B on the P1 ) that provide cross-segment redundancy for U.S. and partner elements, isolating failures to maintain cooling for critical functions, while the segment's autonomous thermal control complements this architecture across the multinational ISS structure.

System Components

Primary Loops and Fluid

The External Active Thermal Control System (EATCS) of the (ISS) employs two independent primary loops, designated Loop A on the starboard side (S1 ) and Loop B on the port side (P1 ), to ensure redundancy and prevent single-point failures in heat rejection. Each loop operates as a closed-circuit system that circulates liquid to transport heat from ISS payloads and electronics to external radiators, with the loops physically separated to minimize risks from or orbital debris impacts. This architecture allows the system to maintain full operational capacity even if one loop experiences a fault, through cross-strapping mechanisms that enable reconfiguration for complete recovery. Ammonia was selected as the working fluid for these primary loops due to its high thermal capacity and wide operating temperature range, which are critical for efficient in the vacuum of space. It exhibits a high , enabling effective cooling of high-heat-load components, along with a low freezing point of approximately -78°C and a of -33°C, ensuring the fluid remains liquid under the extreme thermal conditions encountered on without risking changes or solidification. The use of high-purity ammonia (99.998%) in these loops supports reliable performance, with each loop containing about 640 pounds (290 kg) of the fluid to handle surge volumes and maintain system pressure. Key components integral to the primary loops include the Tank Assembly (NTA) and the Tank Assembly (ATA), which manage pressure and fluid inventory, respectively. The NTA utilizes high-pressure gas (up to 2,500 psia) to regulate the loop pressure at around 390 psia, preventing and ensuring consistent flow; it is designed as an orbital replaceable unit weighing approximately 460 pounds (209 kg). The ATA serves as the primary reservoir for liquid , incorporating two pressure vessels separated by a for volume compliance and surge management during thermal expansions or contractions, and it too is isolatable and replaceable via , weighing about 1,120 pounds (508 kg) per unit. These assemblies contribute to the loops' fault-tolerant design by allowing isolation of leaks or anomalies, such as through radiator beam modules that enable venting and segment-specific shutdowns without compromising the entire system.

Heat Exchangers and Pumps

The heat exchangers in the External Active Thermal Control System (EATCS) primarily consist of interface heat exchangers (IFHXs) that facilitate the transfer of thermal loads from the Internal Active Thermal Control System (IATCS) water loops to the external loops. These IFHXs employ a compact plate-fin counterflow design, featuring alternating layers of fins—typically 23 for water and 22 for in a 45-layer —to maximize efficiency while minimizing size and weight. Located at key module interfaces, such as the U.S. Laboratory (Destiny), Node 2 (Harmony), and Node 3 (Tranquility), each IFHX measures approximately 25 inches by 21 inches by 8 inches and weighs about 91 pounds, with supplied at around 37°F to absorb heat from the warmer water side. Pump modules (PMs) serve as the primary propulsion components in the EATCS, circulating anhydrous ammonia through each of the two independent loops to transport acquired heat to the radiators. Each PM integrates a single centrifugal canned-motor pump, a fixed-charge accumulator for pressure regulation, a pump and control valve package (PCVP) for flow and temperature management, and associated sensors, all housed within a unit weighing approximately 780 pounds and measuring 69 inches by 50 inches by 36 inches. Positioned one per loop on the S1 and P1 truss segments, the PMs operate at nominal pressures of 300 psia (with a maximum design of 500 psia) and deliver flow rates of up to 8,200 pounds per hour for Loop A (at 11,500 rpm) and 8,900 pounds per hour for Loop B (at 14,700 rpm), powered by the International Space Station's electrical systems with provisions for redundancy through dual-loop architecture and isolation capabilities. The PCVP includes control valves and firmware for precise operation, while isolation valves in the associated return branch valve modules (RBVMs) enable segmenting the loop during anomalies. Quick disconnect assemblies (QDAs) are integral to the EATCS for facilitating and repairs by allowing modular disconnection of components like PMs and IFHXs without depressurizing the entire loop. These self-sealing QD fittings, used at fluid line interfaces, isolate potential leaks—such as those from seal degradation—and support orbital replacement unit (ORU) exchanges during extravehicular activities, ensuring system integrity and minimizing exposure risks.

Radiators and Joints

The Heat Rejection System Radiators (HRSRs) serve as the primary external hardware for dissipating thermal energy from the External Active Thermal Control System (EATCS) on the (ISS). These radiators operate by rejecting heat via to deep , utilizing single-phase ammonia flow within the loops to maintain stable thermal transport in microgravity environments. Each of the two EATCS loops incorporates three HRSR Orbital Replacement Units (ORUs), each consisting of eight panels, enabling efficient without the complications associated with two-phase flow regimes. Deployed on the S1 and P1 trusses of the ISS, the HRSRs support the system's overall heat rejection capacity. The panels are constructed from lightweight, high-emissivity materials, such as aluminum structures coated for optimal emission, ensuring while minimizing mass and structural loads on the station. This configuration allows the radiators to handle varying thermal loads from ISS payloads and subsystems by radiating excess heat directly into the vacuum of space. The Thermal Rotary Joint (TRJ) facilitates mechanical accommodation and dynamic positioning of the HRSRs on the ISS structure. This joint enables up to ±115° rotation of the assemblies, optimizing their orientation to avoid direct solar exposure and manage angles—the angle between the and —for maximum cooling efficiency. By allowing controlled articulation, the TRJ ensures that the s can be positioned edge-on to during orbital daylight phases and face toward cold during eclipse, preventing overheating or freezing of the fluid. The design incorporates fluid transfer paths for , along with electrical and data interfaces, to support seamless operation across the rotating interface without leaks or performance degradation in the harsh .

Operational Principles

Heat Acquisition Process

The heat acquisition process in the External Active Thermal Control System (EATCS) begins with the capture of thermal loads from various sources within the of the . Heat is primarily acquired through cold plates attached directly to external power equipment, such as Direct Current to Direct Current Conversion Units (DDCUs) and Main Bus Switching Units (MBSUs), which manage the high-power demands of the station's electrical systems. Each DDCU typically features three cold plates, each capable of removing approximately 694 W of heat at a of 125 , while MBSUs use two cold plates per unit, each dissipating around 495 W at 80 . For internal heat sources, acquisition occurs via Interface Heat Exchangers (IFHX) that transfer thermal energy from the Internal Active Thermal Control System (IATCS) water loops to the EATCS ammonia loops. These exchangers interface with heat generated by , scientific experiments in the Japanese Experiment Module (JEM) and Orbital Facility (COF), and power conversion units, collectively producing a total load of 50-70 kW across the system. The EATCS is standardized for , excluding the , which employs separate thermal control systems. The core mechanism relies on single-phase liquid as the working fluid, which absorbs conductively from the cold plates and exchangers without undergoing phase change. This process maintains equipment temperatures within a controlled range of -20°C to 50°C, ensuring operational reliability for sensitive components like and payloads. is supplied at approximately 37°F (2.8°C) ± 2°F to optimize pickup .

Fluid Circulation and Management

The fluid circulation in the External Active Thermal Control System (EATCS) is primarily driven by mechanically pumped single-phase anhydrous ammonia flowing through two independent closed loops (Loop A and Loop B), each equipped with a Pump Module (PM) that operates at constant mass flow rates to ensure reliable heat transport across the system. The PM, which integrates the pump, an accumulator, and a Pump and Control Valve Package (PCVP), circulates ammonia at nominal rates of approximately 8,200 lb/hr (1.03 kg/s) for Loop A and 8,900 lb/hr (1.12 kg/s) for Loop B, with initial activation flows starting lower at around 5,000 lb/hr (0.63 kg/s) and 5,200 lb/hr (0.66 kg/s) respectively to facilitate safe startup. Valves within the PCVP, including a Flow Control Valve (FCV), enable precise mixing of cooler radiator return flow with warmer inflow from Interface Heat Exchangers (IFHXs) to maintain ammonia supply temperatures at 37°F (2.8°C) ± 2°F (1.1°C), while Radiator Beam Valve Modules (RBVMs) provide isolation capabilities and flow balancing between the dual flow paths in each radiator assembly, allowing reconfiguration to isolate faulty segments without halting overall circulation. Fluid management in the EATCS relies on pressurization and accommodation systems to sustain loop integrity under varying thermal conditions in the space environment. The Nitrogen Tank Assembly (NTA), located on the S1 and P1 truss segments, supplies high-pressure nitrogen (initially at 2,500 psia) that is regulated to maintain nominal operating pressures of 300 psia at the pump inlet, with startup pressures reaching 390 psia and a maximum design limit of 500 psia to propel ammonia from the Ammonia Tank Assembly (ATA). The ATA, positioned on the zenith side of the S1 and P1 trusses, stores approximately 640 lb (290 kg) of ammonia per loop and incorporates an accumulator to manage thermal expansion, accommodate vapor voids, and prevent overpressurization during temperature fluctuations or resupply operations. This design leverages ammonia's favorable thermophysical properties, such as its high latent heat and low freezing point, to support efficient circulation without phase changes under nominal conditions. Monitoring and control are achieved through an array of sensors integrated into the PM and RBVMs, which continuously track key parameters including at the pump inlet and returns, across the loop, and rates to detect anomalies like pressure drops or imbalances. Redundant controllers, implemented via the Thermal Control System (TCS) software running on /Demultiplexer (MDM) computers, ensure uninterrupted operation by automatically responding to faults—such as a loop failure—through isolation valves and rerouting, with provisions for ground-commanded reconfiguration to redistribute loads between the two loops for continued heat transport capacity of up to 35 kW per loop. In the event of a primary loop degradation, the system supports automatic switchover mechanisms to maintain overall functionality, drawing on the independent design of Loops A and B to avoid single-point failures.

Heat Rejection Mechanism

The heat rejection mechanism in the External Active Thermal Control System (EATCS) relies on Heat Rejection System Radiators (HRSRs), which dissipate thermal energy collected by the loops through passive to the space environment. These radiators, each consisting of 24 panels (three orbital replacement units, each with eight panels) mounted on the ISS starboard (S1) and (P1) truss segments, respectively, operate in the vacuum of where is absent, ensuring occurs solely via without active cooling elements. The effective sink for is approximately 210 , accounting for environmental factors such as Earth's and emissions. Anhydrous enters the HRSRs at a supply temperature of about 3°C and cools to an outlet target of -40°C as it traverses the panels, enabling efficient before returning to the loop. The radiator panels feature a white Z-93 coating on their surfaces, providing low absorptivity (around 0.13–0.17) and high (0.89–0.93) to maximize rejection while minimizing unwanted heating. Fin efficiency of the design achieves approximately 85%, contributing to the system's overall performance in rejecting up to 70 kW of heat. To optimize rejection and prevent overheating, the Thermal Radiator Rotary Joints (TRJs) enable continuous rotation of the radiator wings, positioning them edge-on to during sunlight phases and facing during eclipses, thereby minimizing solar absorption across varying orbital conditions including beta angles up to 90°. This dynamic orientation, driven by the Radiator Goal Angle Calculation algorithm, ensures consistent thermal performance in the absence of atmospheric cooling mechanisms.

Development and History

Early External System (EEATCS)

The Early External Active Thermal Control System (EEATCS) served as a temporary solution during the initial assembly stages of the (ISS), providing essential cooling for the U.S. Laboratory module (Destiny) prior to the deployment of the permanent system. Designed with a limited heat rejection capacity of 14 kW, the EEATCS utilized two independent loops to collect from the laboratory's Interface Heat Exchangers (IFHX) located on the module's aft endcone. These loops circulated anhydrous as the working fluid, enabling efficient heat transport in the of space. Key components of the EEATCS included two radiator assemblies and a dedicated pump package, which facilitated the initial cooling requirements for Destiny by circulating fluid and rejecting heat via radiation to deep space. The s, each measuring approximately 10.24 feet by 44.62 feet and orthogonally oriented for optimal exposure, were mounted on the , while the pump and flow control subassemblies (PFCS)—two per loop, incorporating valves and accumulators—were integrated with fluid lines routed across the for connectivity. This configuration ensured redundancy and reliability during the early operational phase, when the full was not yet complete. The system's hardware was launched as part of the early ISS assembly, with the delivered on aboard on November 30, 2000, and the on in October 2000; radiators were deployed via during in February 2001. As an interim measure, the EEATCS operated from ISS assembly flight 5A through 12A.1, supporting habitable volumes until the higher-capacity External Active Thermal Control System (EATCS) became available. It was deactivated during STS-116 in December 2006, with components subsequently decommissioned, relocated, or repurposed as spares for other thermal control elements.

Full EATCS Deployment

The full External Active Thermal Control System (EATCS) was deployed through the installation of its primary components on the S1 and P1 integrated truss structures during the 2002 International Space Station (ISS) assembly phase. The starboard Loop A was integrated as part of the S1 truss, delivered and attached to the central S0 truss by Space Shuttle Atlantis during mission STS-112 from October 7 to 16, 2002. This installation involved three extravehicular activities (EVAs) to secure the truss, connect power and data interfaces, and prepare thermal lines, supported by the Space Station Remote Manipulator System (SSRMS) robotic arm for precise positioning and handover. Similarly, the port Loop B was incorporated into the P1 truss, launched aboard Space Shuttle Endeavour on STS-113 from November 23 to December 7, 2002, with additional EVAs and SSRMS operations to mate it to the S0 truss and route initial fluid connections. These steps established the structural foundation for the dual-loop ammonia-based system, each loop featuring pump modules, heat exchangers, and radiators designed for independent operation. Activation of the complete EATCS occurred during Space Shuttle Discovery's mission from December 9 to 22, 2006, marking the transition from the temporary Early External Active Thermal Control System (EEATCS) to the permanent setup. During EVAs 2 and 3, astronauts connected the loops to the U.S. Laboratory's interface heat exchangers, filled them with anhydrous , and initiated pump operations—Loop B first on flight day 6, followed by Loop A on flight day 8—achieving initial flow rates of approximately 5,000 pounds per hour per loop. The SSRMS and ground control coordinated the reconfiguration, including purging and power domain adjustments, to ensure safe startup without overloads. By the mission's end, the system reached its full 70 kW heat rejection capacity (35 kW per loop), enabling cooling for external electronics like Main Bus Switching Units and supporting the ISS's expanding power generation. Concurrently, the EEATCS radiators on the P6 were deactivated and relocated to provide spares for photovoltaic control loops. This phased rollout synchronized EATCS integration with subsequent ISS module additions, ensuring thermal management scalability. Connections to Node 2 were completed during in October 2007, while Node 3, the Japanese Experiment Module (JEM), and Columbus Orbital Facility (COF) interfaces followed in 2008–2010, leveraging the loops' quick-disconnect fittings for modular expansion without disrupting operations. The deployment exemplified coordinated human and robotic efforts, with EVAs handling fluid line matings and SSRMS facilitating truss handling, ultimately providing robust, redundant cooling for the station's U.S. segment and international partners.

Challenges and Maintenance

Ammonia Leaks and Failures

The External Active Thermal Control System (EATCS) on the (ISS) has experienced several leaks and component failures since its deployment, primarily affecting the photovoltaic thermal control subsystems and main cooling s. One early incident occurred in 2004, when the P6 's 2B of the initial Photovoltaic Thermal Control System (PVTCS) began a slow leak at a rate of 0.75 to 1.5 pounds per year (lbm/yr), which gradually increased over time. In July 2010, a pump module failure in the starboard A at the S1 halted circulation, necessitating contingency cooling operations and eventual replacement. The port-side B faced escalating issues starting in 2011 with a slow leak in the P1 , which accelerated in 2013, leading to visible crystals and heightened monitoring. Between 2015 and 2019, intermittent leaks persisted in B, including a 2015 indication of an leak that prompted temporary crew relocation to the for safety, and a 2017 surge to approximately 101 lbm/yr, requiring loop isolation to maintain operations. These failures have been attributed to factors such as seal degradation, manufacturing defects in quick disconnect assemblies (QDAs) and pumps, and potential micro-meteoroid orbital (MMOD) impacts on fluid lines. For instance, of the P1 leak revealed defective seals and plating as primary contributors to the acceleration. Pump modules, in particular, have shown vulnerability to premature wear, as seen in the 2010 S1 event. The pump module malfunction in Loop B reduced the system's to approximately 50%, relying on the redundant Loop A and prompting contingency power-downs of non-essential systems to manage thermal loads. Across these major events, an estimated 10-20 kg of has been lost, based on integrated rates from pressure telemetry and isolation data. Ammonia leaks in the EATCS typically manifest as visible white plumes of frozen crystals observable from the ISS exterior, often confirmed during visual inspections or robotic surveys. They are initially detected through drops in system pressure monitored via onboard , supplemented by mass spectrometers in tools like the Robotic External Leak Locator (RELL) for precise composition analysis and localization. In 2022, signs of an accelerating ammonia leak were detected in the starboard Loop A (S1) EATCS using pressure telemetry and RELL scans, narrowing the source to potential seal issues similar to prior events; as of November 2025, monitoring continues without reported major repairs or capacity loss.

Repair Operations and Spacewalks

Repair operations for the External Active Thermal Control System (EATCS) on the International Space Station (ISS) primarily involve extravehicular activities (EVAs), or spacewalks, to address issues such as ammonia leaks and component failures. These procedures emphasize safety protocols to mitigate the toxicity risks associated with ammonia exposure, including the use of the Simplified Aid for EVA Rescue (SAFER) jet backpack for mobility and tethers for restraint during operations near potential leak sites. Astronauts follow ground-in-the-loop planning, where mission control in Houston monitors real-time telemetry from the ISS to guide tasks and ensure system integrity. Ammonia scavenging protocols are employed prior to disconnections, involving controlled venting of the isolated segment to space to minimize residual fluid that could contaminate suits or equipment. A core procedure for isolating faulty sections of the EATCS loops is the activation of isolation valves to segment the system, preventing further loss while maintaining cooling for critical components. This is followed by disconnections using Quick Disconnect Assemblies (QDAs), which allow safe separation of hoses or modules without fluid spillage. Component replacements, such as pump modules or jumper hoses, utilize spare Orbital Replacement Units (ORUs) like the Spare Pump Module or pre-stowed jumper lines transported via cargo vehicles. After replacement, post-repair leak checks are conducted through pressure and quantity tests to verify system stability before resuming full operations. These steps ensure minimal and preserve the dual-loop of the EATCS. Key spacewalks dedicated to EATCS repairs include the 2013 series of three EVAs targeting a suspected leak source on the P1 . On December 21, 2013 (U.S. EVA 30), astronauts Rick Mastracchio and Michael Hopkins removed the faulty Pump and Flow Control Subassembly (PFCS) from Loop B, stowing it for later return to . The subsequent EVAs on December 24 (U.S. EVA 31) and December 25 (U.S. EVA 32) involved installing a replacement PFCS using the spare unit and reconnecting QDAs, successfully restoring Loop B functionality after isolating the section via valves. These operations addressed the pump malfunction detected earlier that month, with ground teams confirming no further leaks via post-EVA pressure tests. Another significant effort addressed the slow ammonia leak in Loop B from 2011 to 2017, culminating in a 2018 spacewalk for inspection and component removal, followed by planned recharge activities. During U.S. 49 on March 29, 2018, astronauts Drew Feustel and Ricky Arnold inspected and disconnected two jumper hose assemblies from the P1-3-2 Radiator Beam Valve Module (RBVM), returning them to for analysis that identified defective seals as the leak source. The isolated segment was vented and scavenged beforehand to reduce toxicity risks. Refurbished hoses were launched in 2019, with reinstallation via EVA in 2020 to recharge and restore the loop, supported by spare Tank Assemblies (ATAs) for fluid replenishment. Over 10 EVAs have been dedicated to EATCS maintenance since its full deployment in 2006, highlighting the system's reliance on human intervention for long-term reliability.

Specifications and Performance

Capacity and Efficiency

The External Active Thermal Control System (EATCS) on the features a nominal heat rejection capacity of 70 kW total, with each of the two independent loops rated at 35 kW under dual-loop operation. This capacity supports continued functionality if one loop is isolated. The system's design incorporates margins for a 15-year operational , accommodating variable loads from as low as 10 kW during reduced-power phases to the full 70 kW maximum, aligned with fluctuations in ISS photovoltaic power generation and module utilization. The fundamental in each loop follows the convective equation Q = \dot{m} \, c_p \, \Delta T where Q is the rejection rate (up to 35 kW per ), \dot{m} is the , c_p is the of liquid (about 4.7 kJ/kg·K), and \Delta T is the temperature rise across heat acquisition components. Flow rates and temperature differentials vary to maintain thermal balance across diverse orbital environments.

Fluid Properties and Safety

The used in the External Active Thermal Control System (EATCS) exhibits key physical properties that make it suitable for single-phase in the of . Its liquid density is approximately 630 kg/m³ at operating temperatures around 0–10°C, providing efficient mass transport within the closed loops. The of vaporization is 1,370 kJ/kg near its of -33°C, enabling effective phase change if needed during contingencies, though the system primarily operates in liquid form. Thermal of the liquid is about 0.5 W/m·K, facilitating rapid heat dissipation to radiators. is non-corrosive to the aluminum alloys used in EATCS , ensuring long-term structural integrity, but its high toxicity necessitates stringent containment. Safety considerations for ammonia in the EATCS stem primarily from its toxicity, with an Immediately Dangerous to Life or Health (IDLH) concentration of 300 , far below which crew exposure must be maintained. The system employs fully sealed, redundant loops to prevent any release into habitable modules, isolating the external ammonia circuits from internal water-based systems due to biocompatibility issues that could contaminate if mixed. Quick-disconnect seals on components are rated for leak rates as low as 10^{-4} scc/s under nominal conditions, minimizing unintended venting. The total ammonia inventory is approximately 290 kg per loop, stored in tank assemblies to support extended operations. To mitigate freezing risks, given ammonia's freezing point of -77°C, the EATCS incorporates electrical heaters along plumbing lines and bypass segments, maintaining fluid temperatures above -60°C even during low-heat-load periods or off-nominal orientations. These heaters, totaling about 1.8 kW per loop, prevent solidification that could damage lines or valves. During extravehicular activities (EVAs) near potential leak sites, protocols establish exclusion zones of roughly 100 m to avoid ammonia plume contamination, with procedures for suit decontamination if crystals are detected. Leak handling during repairs involves isolating affected segments and venting residual ammonia, as detailed in maintenance operations.

References

  1. [1]
    [PDF] Active Thermal Control System (ATCS) Overview - NASA
    The External Active Thermal Control System (EATCS), activated for the first time on this mission, consists of ammonia loops to collect heat from the Interface ...
  2. [2]
    [PDF] International Space Station Passive Thermal Control System Top ...
    Jul 12, 2018 · Key areas to be presented include thermal model fidelity, verification methods, analysis uncertainty, and operations support. I. Introduction.
  3. [3]
    [PDF] Ammonia Release on ISS
    INTERNATIONAL. SPA CE STATI ON. Main Sources of Ammonia on ISS. • USOS Thermal Control System. • Provides thermal control to USOS (include Columbus and JEM).
  4. [4]
    [PDF] The International Space Station (ISS) Port 1 (P1) External Active ...
    Jul 11, 2019 · Ammonia is used in the External Active. Thermal Control System (EATCS) to cool the pressurized modules and external electrical systems.
  5. [5]
    ISS Active Thermal Control System(ATCS) Heat Exchangers and ...
    Jul 1, 1997 · The International Space Station's primary external heat transport system is a single phase ammonia loop called the Active Thermal Control System (ATCS).
  6. [6]
    None
    ### Summary of Plate-Fin Heat Exchangers in Active Thermal Control System for Space Station
  7. [7]
    [PDF] ISS Ammonia Pump Failure, Recovery, and Lesson Learned
    The pump module ORU houses the pump, controls, and valves required to maintain proper temperature in the heat rejection loop. A canned motor cartridge pump ...Missing: EATCS | Show results with:EATCS
  8. [8]
    [PDF] ISS Internal Active Thermal Control System (IATCS) Coolant ...
    This paper presents an overview of the anomalies, their known and suspected system effects, their causes, and the actions being taken to remediate the coolant.
  9. [9]
    [PDF] Advanced Active Thermal Control Systems Architecture Study
    The internal thermal control system collects heat from the cabin occupied by humans. This heat is rejected to the external thermal control system. The ...
  10. [10]
    The International Space Station ECLS and thermal control systems
    The 155 Thermal Control System (TCS) consists of an Early External Active Thermal Control System (EEATCS) for early implementation on the Z1IP6 truss for ...
  11. [11]
    View of the aft EEATCS radiator deployment - DVIDS
    Oct 17, 2012 · Views of the aft Early External Active Thermal Control System (EEATCS) radiator unfurling / deployment on the P6 truss structure during Extravehicular Activty ...
  12. [12]
    STS-112 - NASA
    Primary payloads for STS-112 were the S1 integrated truss segment and the Crew and Equipment Translation Aid Cart A. The CETA is the first of two ...Missing: EATCS | Show results with:EATCS
  13. [13]
  14. [14]
    [PDF] The International Space Station 2B Photovoltaic Thermal Control ...
    May 11, 2013 · International Space Station's 2B electrical power channel began slowly leaking ammonia overboard. Initially, the operations strategy was ...Missing: incidents | Show results with:incidents
  15. [15]
    [PDF] ISS Ammonia Pump Failure, Recovery, and Lesson Learned
    Such a scenario began on July 31, 2010 with the premature failure of an ammonia pump on the external active thermal control system of the International Space ...Missing: incidents | Show results with:incidents
  16. [16]
    The International Space Station (ISS) Port 1 (P1) External Active ...
    Aug 26, 2019 · Ammonia is used in the Starboard 1 (S1) and Port 1 (P1) External Active Thermal Control System (EATCS) to cool the pressurized modules, ...Missing: rationale paper
  17. [17]
    Crew Back at Work Studying Immune System in Space - NASA
    Jan 15, 2015 · The International Space Station residents were back at work Thursday after an ammonia leak indication sent the crew over to the Russian segment.Missing: incidents | Show results with:incidents
  18. [18]
    [PDF] International Space Station (ISS) Environmental Control and Life ...
    The United States External Active Thermal Control System (EATCS) on the International Space Station (ISS) uses liquid ammonia in closed loops to collect ...
  19. [19]
    [PDF] Coolant Leak from ISS External Active Thermal Control System ...
    Jul 14, 2022 · The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that ...
  20. [20]
    [PDF] Extending the Operational Life of the International Space Station ...
    Sep 18, 2014 · Source: NASA's ISS Program. The loop A Pump Module failed twice in the past 3 years, most recently in December. 2013. Although loop B continued ...
  21. [21]
    [PDF] The Demonstration of a Robotic External Leak Locator on the ...
    This paper discusses the results of these exercises including measurements of the environment around ISS, detection of a small ammonia leak and implementation ...
  22. [22]
    International Space Station Spacewalks - NASA
    There have been 275 spacewalks at the International Space Station since December 1998. NASA. 2025. Date: May 1, 2025. Duration: 5 hours, 49 minutes
  23. [23]
    ISS Daily Summary Report – 12/17/13 - NASA
    Dec 17, 2013 · USOS EVA and Orbital Status: A Program decision was made to pursue USOS EVAs on December 21st, 23rd, and 25th (if required) in order to ...
  24. [24]
    Spacewalkers complete first Pump Module replacement EVA
    Dec 20, 2013 · US astronauts aboard the International Space Station (ISS) have completed the first of the planned Extra Vehicular Activities (EVAs) to replace a failed Pump ...Missing: EATCS | Show results with:EATCS
  25. [25]
    Nasa astronauts complete ISS Christmas Eve spacewalk
    Dec 24, 2013 · Astronauts have completed an eventful Christmas Eve spacewalk during which they replaced a critically damaged coolant pump module aboard the International ...
  26. [26]
    EVA-49 - spacewalkers complete ISS upgrading tasks
    The next task for the two spacewalkers was to remove two ammonia jumpers from a Radiator Beam Valve Module (RBVM) on the P1 Truss. An RBVM is ...
  27. [27]
    [PDF] The International Space Station Internal Active Thermal Con
    The NASA STI program provides access to the NASA Aeronautics and. Space Database and its public interface, the NASA. Technical Report Server, thus providing one ...
  28. [28]
    Designing problems of two-phase central thermal control system for ...
    1) The planned on-orbit life-time of the system is 15 The basic design parameters of the system are the years. following: The principal scheme of ISSA iTS is ...
  29. [29]
    How much electrical energy is required to dissipate heat?
    Apr 13, 2021 · On ISS it takes 0.55 kW of electricity to operate two coolant pumps, in order to radiatively dissipate ~14kW to space. Hence, a preliminary estimate is 0.04 kW ...Missing: EATCS module
  30. [30]
    A Service Call In Space - IIAR
    The Active Thermal Control System is comprised of 3 cooling sub-systems: The External Active Thermal Control System (EATCS) which uses anhydrous ammonia as a ...Missing: SSU | Show results with:SSU
  31. [31]
    Ammonia - Specific Heat vs. Temperature and Pressure
    The calculator below can be used to estimate the specific heat of gaseous ammonia at constant volum or constant pressure and at given temperature and pressure.
  32. [32]
    Ammonia - Thermophysical Properties - The Engineering ToolBox
    Specific heat (heat capacity), Cp (gas), 37.0, J/mol K ; Specific heat (heat capacity), Cp (liquid), 80.8, J/mol K ; Specific heat ratio - Cp/Cv (gas), 1.32.
  33. [33]
    Ammonia - NH3 - Thermodynamic Properties
    Online calculator, figures and tables showing thermal conductivity of liquid and gaseous ammonia at temperatures ranging -70 to 425 °C (-100 to 800 °F) at ...Missing: EATCS | Show results with:EATCS