Downtime refers to the period during which a , device, or process—most commonly in , , or —is unavailable or non-operational due to faults, , or external disruptions. In technical reliability metrics, it contrasts with uptime, where availability is calculated as the proportion of total time minus downtime, often expressed in "nines" (e.g., 99.9% equates to roughly 8.76 hours of allowable downtime per year). Primarily arising from hardware failures, software bugs, network outages, human errors, or cyberattacks, downtime imposes substantial economic costs, with estimates for unplanned outages in large enterprises averaging $5,600 to $9,000 per minute in lost productivity and revenue. In manufacturing and business operations, it manifests as halted production lines or idle workers, exacerbating supply chain delays and customer dissatisfaction. Efforts to mitigate downtime emphasize , via tools, and rapid incident response protocols, though complete elimination remains impractical due to inherent complexities and unforeseen events like power failures or . While occasionally used colloquially for personal rest periods, the term's core application in empirical analyses centers on quantifiable operational interruptions, underscoring causal links between flaws and measurable degradation.

Definition and Classifications

Core Definition

Downtime refers to any period during which a , , , or is unavailable or non-operational, preventing normal use or production. This encompasses both planned interruptions, such as scheduled , and unplanned outages resulting from failures or external events. In and , downtime specifically measures the duration when servers, networks, applications, or components fail to deliver core services, often quantified as a proportion of total operational time (e.g., via metrics like ). Such periods can stem from hardware malfunctions, software bugs, or power disruptions, directly impacting service availability and user access. In and industrial contexts, downtime denotes the halt in lines or operation, typically due to breakdowns, setup times, or shortages, with unplanned instances often costing facilities thousands per minute in lost output. Overall, minimizing downtime is critical for efficiency, as even brief episodes can cascade into significant economic losses across sectors.

Types of Downtime

Downtime in and IT systems is primarily classified into two categories: planned and unplanned. Planned downtime refers to scheduled interruptions for activities such as , software updates, or hardware upgrades, typically arranged during low-usage periods to minimize disruption. downtime, by contrast, arises from unforeseen events like system failures or errors, leading to sudden unavailability without prior notification. Planned downtime allows organizations to prepare by notifying users, backing up data, and implementing failover mechanisms, thereby reducing overall impact on operations. For instance, it often occurs during weekends or overnight hours in environments to align with business cycles. This type is intentional and budgeted, forming part of standard operational protocols in management. Unplanned downtime, often termed unscheduled, stems from reactive responses to issues and can cascade into broader outages if not contained swiftly. It accounts for a significant portion of total downtime incidents in IT, with studies indicating it frequently results from malfunctions or errors rather than deliberate actions. Unlike planned events, it lacks advance scheduling, amplifying recovery times and potential risks. A subset of downtime, partial or degraded downtime, involves scenarios where core services remain partially operational but at reduced capacity, such as slowed response times or limited feature access, distinct from full outages. This classification emphasizes the spectrum of availability impacts beyond on/off states in modern distributed systems.

Telecommunication-Specific Classifications

In , outages—periods of downtime—are systematically classified under standards like TL 9000, a framework developed specifically for the by the QuEST Forum to enhance supplier accountability and network reliability. These classifications categorize outages primarily by root cause, with attributions to the supplier, , or third parties, enabling precise measurement of service impact (SO), network element impact (SONE), and support service outages (SSO). This approach differs from general IT downtime metrics by emphasizing telecom-specific factors such as facility isolation, traffic overload, and procedural errors in large-scale network operations. Outages are further distinguished by severity and scope, often based on and affected infrastructure. For instance, a study on networks modeled daily downtime severity into five categories by : negligible (under 1 minute), minor (1-5 minutes), moderate (5-15 minutes), major (15-60 minutes), and critical (over 60 minutes), with the majority of incidents falling into categories but cumulative effects impacting availability targets like 99.999% uptime. Total outages, where all fail across a , contrast with partial outages affecting subsets of users or functions, such as latency-induced degradations without complete service loss.
CategoryDescriptionAttribution Example
Hardware FailureRandom failure of hardware or components unrelated to design flaws.Supplier
Design - HardwareOutages stemming from hardware design deficiencies or errors.Supplier
Design - SoftwareFaulty software design or ineffective implementation leading to downtime.Supplier
ProceduralHuman errors by supplier, service provider, or third-party personnel during operations.Varies by party
Facility RelatedLoss of interconnecting facilities isolating a network node from the broader system.Third Party
Power Failure - CommercialExternal commercial power disruptions.Third Party
Traffic OverloadExcess traffic surpassing network capacity thresholds.Service Provider
Planned EventScheduled maintenance or upgrades causing intentional downtime.Varies
These cause-based categories support and , with TL 9000 requiring reporting of outages exceeding defined thresholds, such as those impacting more than a specified of subscribers or circuits. Unlike broader IT classifications, telecom standards prioritize end-to-end service continuity, incorporating metrics from bodies like the for availability parameters, though ITU focuses more on definitional frameworks than granular outage typing. Planned outages, such as those during maintenance windows, are distinguished from unplanned ones to align with agreements (SLAs) mandating minimal customer-impacting downtime, often quantified in seconds per year for "" reliability.

Historical Development

Early Computing Era (Pre-1980s)

The earliest electronic computers, such as the completed in 1945 and dedicated in 1946, were hampered by frequent hardware failures inherent to technology. Containing approximately 18,000 tubes, experienced mean times between failures (MTBF) of just a few hours initially, resulting in the system being nonfunctional about half the time due to tube burnout, power fluctuations, and overheating. Engineers addressed these by reducing power levels and selecting more robust components, eventually achieving MTBF exceeding 12 hours, with further improvements by 1948 extending it to around two days. Thermal management was essential, as the machine's 30-ton mass generated excessive heat, triggering automatic shutdowns above 115°F to prevent catastrophic failures. The , delivered in 1951 as the first commercial general-purpose computer, incorporated about 5,200 vacuum tubes and continued to face similar reliability challenges, often managing runs of only ten minutes or less before tube failures or related issues halted operations. Mitigation strategies included rigorous pre-use testing of tube lots and slow warm-up procedures for filaments to minimize stress, which enhanced stability for commercial tasks like tabulation. Despite these efforts, downtime remained prevalent, exacerbated by the absence of and the need for manual interventions, such as replacing faulty tubes or recalibrating circuits, which could take hours. By the late 1950s and 1960s, the advent of transistors supplanted vacuum tubes in systems like IBM's System/360 family, announced in 1964, yielding substantial gains in component durability and reducing failure rates from thermal and electrical stresses. However, overall system hovered around 95% for many mainframes of the era, with downtime still dominated by malfunctions, electromechanical peripherals like tape drives, and environmental factors such as power instability. Programming via patch panels or early assembly languages demanded extensive reconfiguration between tasks—sometimes days—effectively constituting planned downtime in batch-oriented workflows, where machines operated in discrete shifts rather than continuously. Formal metrics for downtime were rudimentary, relying on operator logs of run times and repair intervals rather than standardized availability percentages, reflecting an era where interruptions were anticipated rather than exceptional.

Rise of the Internet (1980s-2000s)

The development of NSFNET in 1985 marked a pivotal expansion of infrastructure beyond military and academic silos, connecting supercomputing centers at speeds up to 56 kbit/s initially, though congestion emerged by the late as traffic grew. This era saw downtime primarily from maintenance, hardware limitations, and rare large-scale incidents like the November 1988 , which exploited vulnerabilities in Unix systems to self-replicate across approximately 6,000 machines—roughly 10% of the at the time—causing widespread slowdowns and requiring manual cleanups that disrupted research operations for days. With user numbers in the low thousands globally during the , such events had limited broader impact, but they underscored the fragility of interconnected systems reliant on emerging TCP/IP protocols. Commercialization accelerated in the early 1990s following the National Science Foundation's 1991 policy allowing limited commercial traffic on NSFNET and its full decommissioning in 1995, transitioning the backbone to private providers and spurring user growth from about 2.6 million in 1990 to over 147 million by 1998. This shift amplified downtime risks through rapid scaling, dial-up dependencies, and nascent infrastructure; for instance, the January 15, 1990, long-distance network crash, triggered by a in signaling software, halted service for 60,000 customers and blocked 70 million calls over nine hours, indirectly affecting early amid the telecom backbone's overload. Reliability challenges intensified with the World Wide Web's public debut in 1991 and browser releases like in 1993, exposing networks to exponential demand and frequent congestion during peak hours. By the mid-1990s, cyber threats emerged as a primary downtime vector, exemplified by the September 6, 1996, attack on Panix, New York's oldest commercial ISP, which overwhelmed servers with spoofed connection requests at rates of 150-210 per second, rendering services unavailable for several days and disrupting thousands of users in what is recognized as the first documented DDoS incident. Configuration errors compounded these vulnerabilities: on April 25, 1997, a faulty router in autonomous system 7007 in propagated erroneous BGP routing updates, flooding global tables and severing connectivity for up to half the for two hours. Similarly, a July 17, 1997, at Inc.—operator of and key DNS root servers—resulted in the accidental removal of a critical registry entry, crippling domain resolution worldwide for several hours and highlighting single points of failure in the expanding . These incidents, amid user growth to 361 million by 2000, drove awareness of downtime's economic stakes, with early sites facing revenue losses from even brief outages and prompting initial investments in , though protocols like BGP remained prone to propagation errors without modern safeguards. The era's dial-up era further exacerbated unplanned downtimes through line contention and modem failures, often leaving users with busy signals during high-demand periods, as networks strained under the transition from research tool to commercial platform. Overall, the internet's rise revealed causal vulnerabilities in decentralized yet interdependent architectures, where localized faults cascaded globally due to insufficient in scaling infrastructure.

Cloud and Modern Systems (2010s-Present)

The transition to from the 2010s onward emphasized engineered resilience through features like automated , multi-availability zone deployments, and global content delivery networks, aiming to distribute risk across geographically dispersed data centers. Providers such as (AWS), , and routinely offered service level agreements (SLAs) targeting 99.99% monthly uptime for core infrastructure, equivalent to under 4.38 minutes of allowable downtime per month. These commitments reflected a departure from traditional on-premises systems, where downtime often resulted from localized hardware failures, toward shared responsibility models that placed burdens on both providers and users for and . Despite these advancements, outages persisted and sometimes amplified in scope due to interconnected , third-party integrations, and rapid scaling demands, with common causes including errors, misjudgments, and software defects rather than physical breakdowns. A notable example occurred on March 3, 2020, when Azure's U.S. East region endured a six-hour networking disruption starting at 9:30 a.m. ET, limiting access to storage, compute, and database services for numerous customers. Similarly, on December 14, 2020, faced a multi-hour outage triggered by a flawed update, interrupting operations for , , and across multiple regions. In November 2020, an AWS Kinesis Data Streams failure cascaded to affect CloudWatch, , and other services, highlighting vulnerabilities in streaming data dependencies. These incidents underscored that while cloud architectures reduced single-point failures, tight coupling could propagate disruptions widely. In response to recurring issues, the period saw innovations in downtime mitigation, including widespread adoption of container orchestration tools like for dynamic and practices to simulate failures proactively. Empirical trends indicate a decline in overall outage frequency and severity since the early , attributed to matured redundancies and , though cloud-specific events in the have occasionally escalated in economic impact due to pervasive reliance on hyperscale providers— with some analyses noting increased severity from factors like DDoS attacks, as in Azure's July 30, 2024, disruption. About 10% of reported outages in 2022 stemmed from third-party cloud dependencies, reflecting the era's ecosystem complexity. Nonetheless, actual compliance remains high for major providers, with downtime minutes often falling below guaranteed thresholds annually, though critics argue self-reported metrics may understate user-perceived impacts from partial degradations.

Primary Causes

Human Error and Operational Failures

Human error accounts for a substantial portion of IT downtime incidents, with studies indicating it contributes to 66-80% of all outages when including direct mistakes and indirect factors such as inadequate training or procedural gaps. In data centers specifically, human actions or inactions are implicated in approximately 70% of problems leading to disruptions. According to the Uptime Institute's analysis, nearly 40% of organizations experienced a major outage due to human error in the three years prior to 2022, with 85% of those cases stemming from staff deviations from established procedures. Similarly, in 58% of human-error-related outages reported in a 2025 survey, failures occurred because procedures were not followed, underscoring the role of operational discipline in preventing cascading failures. Common manifestations include misconfigurations during maintenance, erroneous software deployments, and overlooked routine tasks like certificate renewals. For instance, on February 28, 2017, ' S3 storage service suffered a multi-hour outage affecting regions worldwide, triggered by a in the update process that inadvertently deleted a critical server capacity pool, halting new object uploads and replications. In another case, endured a three-hour global disruption on February 3, 2019, when an certificate expired without renewal, blocking access for millions of users due to oversight in operational monitoring. These errors often amplify through complex systems, where a single misstep in propagates via scripts or interdependent services. Operational failures tied to human oversight extend to broader procedural lapses, such as insufficient change management or fatigue-induced mistakes during high-pressure updates. The October 4, 2021, Meta outage exemplifies this, lasting six hours and impacting Facebook, Instagram, WhatsApp, and other services for over 3.5 billion users; it originated from a faulty network configuration change executed by engineers, which severed BGP peering and backbone connectivity, compounded by reliance on a single command-line tool without adequate redundancy checks. Such incidents highlight causal chains where initial human inputs, absent rigorous validation, lead to systemic isolation, emphasizing the need for automated safeguards and peer reviews to mitigate error propagation in high-stakes environments. Despite advancements in automation, persistent human factors like knowledge gaps or rushed implementations remain prevalent, as evidenced by recurring patterns in annual outage reports.

Hardware and Software Failures

Hardware failures encompass malfunctions in physical components such as servers, devices, equipment, and supplies, which directly interrupt operations and lead to downtime. These failures often stem from , manufacturing defects, overheating, or power surges, resulting in data unavailability or service disruptions. In data centers, hardware issues account for approximately 45% of outage incidents globally. For small and mid-sized businesses, hardware failure represents the primary cause of downtime and . Annualized failure rates vary by component; for instance, hard disk drives (HDDs) exhibit rates around 1.6%, while solid-state drives (SSDs) are lower at 0.98%. In large-scale environments with thousands of servers, expected annual failures include roughly 20 supplies (1% rate across 2,000 units) and 200 chassis fans (2% rate across 10,000 units). Server crashes due to aging , such as failing hard drives or units, exemplify common scenarios, often exacerbated by inadequate or environmental stressors like dust accumulation and temperature fluctuations. hardware failures, including router or switch malfunctions, contribute to 31% of networking-related outages. In , GPUs demonstrate elevated vulnerability, with annualized failure rates reaching up to 9% under intensive workloads, shortening expected service life to 1-3 years. These incidents underscore the causal link between component degradation and operational halts, where redundancy measures like arrays or systems mitigate but do not eliminate risks. Software failures arise from defects in , configuration errors, or incompatible updates that render applications or operating systems inoperable, precipitating widespread downtime. Bugs in or application logic, such as unhandled exceptions or conditions, frequently trigger crashes during peak loads or after deployments. and software errors account for 26% of networking disruptions in data centers. Configuration changes, often overlooked in testing, contribute to failures by altering behaviors unexpectedly, as seen in incidents where improper handling leads to cascading outages. Combined and software failures represent 13% of downtime causes, highlighting their interplay—such as a software update exposing latent hardware incompatibilities. Notable examples include flawed software updates precipitating system-wide halts, though empirical data emphasizes preventable issues like inadequate error handling over inherent complexity. In aggregate, these failures drive significant operational interruptions, with relying on rigorous testing and rather than over-reliance on unverified vendor assurances.

Cyber Threats and Attacks

Cyber threats, including distributed denial-of-service (DDoS) attacks and , represent a primary vector for inducing downtime by overwhelming systems, encrypting , or exploiting vulnerabilities to force operational halts. These attacks exploit bandwidth limits, software flaws, or human factors to render services unavailable, often for or disruption. According to cybersecurity analyses, DDoS attacks alone accounted for over 50% of reported incidents in 2024, with global efforts blocking millions of such events quarterly. In the UK, incidents have surpassed hardware failures as the leading cause of IT downtime and , particularly affecting larger enterprises. DDoS attacks flood targets with traffic to exhaust resources, causing outages lasting from minutes to days. reported blocking 20.5 million DDoS attacks in Q1 2025, a 358% increase year-over-year, with many targeting , , and cloud services. Incidents more than doubled from 2023 to 2024, reaching over 2,100 reported cases, driven by s and amplification techniques. Notable examples include the 2016 Dyn attack, which disrupted major sites like and for approximately two hours via Mirai traffic peaking at 1.2 Tbps. In 2018, endured a record 1.35 Tbps assault, mitigated within 10 minutes but highlighting vulnerability scales. More recently, a 2023 DDoS hit 2.4 Tbps, underscoring state and criminal actors' use of sophisticated volumetric methods. Ransomware encrypts files or locks systems, compelling victims to pay for decryption keys or face prolonged downtime during recovery. These attacks caused over $7.8 billion in healthcare downtime losses alone as of 2023, with recovery times averaging weeks due to data restoration and verification needs. The 2017 WannaCry variant exploited vulnerabilities, infecting 200,000+ systems across 150 countries and halting operations at entities like the UK's for days. Colonial Pipeline's 2021 DarkSide infection led to a six-day distribution shutdown, prompting a $4.4 million ransom payment amid East Coast shortages. Ransomware targeting industrial operators surged 46% from Q4 2024 to Q1 2025, per 's report, often via or compromises. Other threats, such as wiper malware and advanced persistent threats (APTs), erase data or maintain stealthy access leading to eventual shutdowns. State-sponsored operations, documented in CSIS timelines since 2006, frequently aim at critical infrastructure, causing cascading downtimes in defense and energy sectors. Annual global costs from DDoS-induced downtime exceed $400 billion for large businesses, factoring lost revenue and remediation. Mitigation relies on traffic filtering, backups, and segmentation, though evolving tactics like AI-amplified attacks challenge defenses.

External and Environmental Factors

External and environmental factors contributing to downtime encompass disruptions originating outside an organization's direct control, such as utility failures, natural phenomena, and ambient conditions that impair reliability. Power supply interruptions represent a primary external vector, often stemming from instability or utility provider issues rather than internal generation faults. According to the Uptime Institute's 2022 analysis, power-related events accounted for 43% of significant outages—those resulting in downtime and financial loss—among surveyed data centers and enterprises. This figure underscores the vulnerability of computing infrastructure to upstream energy distribution failures, where even brief fluctuations can cascade into prolonged unavailability without adequate systems. The Institute's 2025 report further identifies power as the leading cause of impactful outages, highlighting persistent risks despite mitigation efforts. Natural disasters amplify these risks through physical damage to facilities, transmission lines, or supporting infrastructure. Flooding, hurricanes, and earthquakes can sever power feeds, inundate server rooms, or compromise structural integrity, leading to extended recovery periods. For instance, the notes that 75% of data centers in high-risk zones have endured power outages tied to such events, often prolonging downtime via secondary effects like access restrictions or equipment corrosion. While older assessments attribute only about 5% of total business downtime directly to , recent trends indicate rising frequency due to intensified weather patterns, with events like in 2017 disrupting critical systems across and causing economic losses in the billions from interdependent infrastructure failures. Empirical data from spatial analyses reveal that over 62% of outages exceeding eight hours coincide with extreme climate events, such as heavy precipitation or storms, emphasizing causal links between meteorological extremes and operational halts. Ambient environmental conditions within and around facilities also precipitate failures by deviating from optimal operating parameters, particularly in uncontrolled or semi-controlled settings. Elevated temperatures strain cooling mechanisms, accelerating component wear; extreme , for example, forces compressors and fans into overdrive, elevating breakdown probabilities in data centers. High fosters and on circuit boards, while low heightens static risks, both capable of inducing sporadic or systemic faults. accumulation, exacerbated by poor sealing against external winds or , clogs vents and impairs airflow, contributing to thermal throttling or outright hardware cessation. Proactive monitoring of these variables— ideally between 18-27°C and at 40-60% relative—mitigates such issues, yet lapses remain a vector for downtime in under-maintained environments. These factors interact cumulatively; for instance, a during a heatwave can compound cooling failures, extending recovery times beyond initial event durations.

Characteristics and Measurement

Duration, Scope, and Severity

refers to the length of time a system or service remains unavailable, typically measured from the point of detection or failure onset to full restoration of functionality. This metric is quantified in units such as minutes or hours and forms the basis for calculations like mean time to recovery (MTTR), which averages the resolution time across multiple incidents. Shorter durations are prioritized in high-stakes environments, where even brief interruptions can amplify consequences due to dependency chains in modern infrastructure. Scope delineates the breadth of the outage's reach, encompassing factors such as the number of affected users, geographic , and proportion of services impacted. Narrow scope might involve a single component or localized affecting a of operations, whereas broad scope extends to widespread user bases or , as seen in cloud service disruptions impacting millions globally. Scope assessment often integrates with data to quantify affected endpoints or request rates, distinguishing isolated glitches from systemic breakdowns. Severity integrates duration, scope, and resultant business impact into a classificatory framework, enabling prioritization and response escalation. The Uptime Institute's Outage Severity Rating (OSR) employs a five-level : Level 1 (negligible, e.g., minor inconveniences with workarounds), Levels 2-3 (moderate to significant, partial service loss), and Levels 4-5 (severe to catastrophic, full mission-critical failure, such as a brief trading system halt causing major financial losses). In IT , common severity tiers like SEV-1 (critical, full outage affecting all users, demanding immediate on-call response) contrast with SEV-3 (minor, limited scope with available mitigations handled in business hours). Data center-specific models, such as the 7x24 Exchange's Downtime Severity Levels (DSL), escalate from minor component faults (Severity 1) to site-wide catastrophic shutdowns (Severity 7), factoring in depth of impact from individual systems to facility-wide compromise. These systems emphasize empirical impact over nominal uptime percentages, recognizing that severity varies by operational context rather than uniform thresholds.

Key Metrics and Quantification Methods

System availability, a primary for assessing downtime, is calculated as the of time a system is operational over a defined period, using the formula: (uptime / total time) × 100%, where uptime equals total time minus downtime. This quantifies overall reliability by excluding planned maintenance and focusing on unplanned unavailability, often tracked via continuous monitoring tools that log service interruptions from incident detection to resolution. Mean time between failures (MTBF) evaluates system reliability by measuring the average operational duration before an unplanned failure occurs, computed as total operating time divided by the number of failures. For instance, if a component operates for 2,080 hours with four failures, MTBF equals 520 hours. Higher MTBF values indicate fewer interruptions, aiding predictions of failure frequency from historical logs excluding scheduled downtime. Mean time to repair (MTTR), or mean time to recovery in incident contexts, gauges repair efficiency as the average duration from detection to full restoration, calculated by dividing total repair time by the number of repairs. An example yields 1.5 hours MTTR for three hours of repairs across two incidents. This metric directly ties to downtime minimization, with data sourced from ticketing systems and repair records to identify bottlenecks in or fixes. Other supporting metrics include mean time to failure (MTTF) for non-repairable systems, equivalent to total operating time divided by failures, and mean time to acknowledge (MTTA), the average from alert to response initiation. These are aggregated from automated logs in IT environments, enabling for proactive improvements, though accuracy depends on precise failure definitions and comprehensive data capture.
MetricFormulaPurpose in Downtime Quantification
(Uptime / Total Time) × 100%Assesses proportion of operational time
MTBFTotal Operating Time / FailuresPredicts failure intervals and reliability
MTTRTotal Repair Time / RepairsMeasures recovery speed and downtime duration
MTTFOperating Time / FailuresEvaluates lifespan for disposable components

Service Level Agreements and Uptime Standards

Service level agreements (SLAs) in and cloud services are contractual commitments between providers and customers that specify expected performance levels, including minimum uptime guarantees to minimize downtime impacts. These agreements typically define uptime as the proportion of time a service remains operational and accessible, calculated as [(total period minutes - downtime minutes) / total period minutes] × 100, excluding scheduled maintenance unless otherwise stated. SLAs often include remedies such as financial credits—typically 10-50% of monthly fees—for breaches, incentivizing providers to maintain through and . Uptime standards are expressed in "nines," representing the percentage of over a period like a month or year, with higher nines correlating to exponentially less allowable downtime. For instance, 99.9% ("three nines") permits up to 8 hours, 45 minutes, and 57 seconds of downtime annually, while 99.99% ("four nines") limits it to 52 minutes and 36 seconds. Industry benchmarks for mission-critical cloud services often target four or five nines, as even brief outages can cause significant losses in sectors like or .
Uptime PercentageAnnual Downtime AllowanceMonthly Downtime Allowance
99.9% (Three Nines)8h 45m 57s43m 50s
99.99% (Four Nines)52m 36s4m 19s
99.999% (Five Nines)5m 15s26s
Major cloud providers enforce these standards variably by service. (AWS) guarantees 99.99% monthly uptime for Amazon EC2 instances in a single region, offering service credits of up to 30% for failures below this threshold. Google Cloud's Compute Engine provides 99.99% for premium network tiers across multiple zones and 99.95% for standard tiers, with credits scaling to 50% for severe breaches. These SLAs emphasize multi-region or multi-zone deployments to compound , as single-instance failures do not trigger credits unless aggregated uptime falls short. Providers measure downtime via internal monitoring, often excluding customer-induced errors or events, which underscores the need for customers to verify metrics.

Economic and Societal Impacts

Direct Financial Costs

Direct financial costs of downtime include lost revenue from interrupted operations, expenditures on immediate repairs and recovery, and penalties from breached agreements or regulatory fines. These costs exclude indirect effects like or lost , focusing instead on quantifiable cash outflows and revenue shortfalls directly attributable to the outage duration. Empirical analyses consistently show these costs scaling with size and sector dependency on continuous service, often measured in dollars per minute or hour of disruption. For Global 2000 companies, aggregate annual downtime costs reached $400 billion in 2024, equivalent to 9% of profits when digital systems fail, with direct components comprising the bulk through revenue cessation and remediation spending. Smaller businesses face per-incident costs averaging $427 per minute in lost sales and fixes, potentially totaling $1 million yearly for recurrent issues. Across enterprises, 90% report hourly downtime exceeding $300,000, while 41% cite $1 million to $5 million per hour, driven primarily by halted transactions and urgent IT interventions. Sector variations amplify these figures, as industries with high transaction volumes or just-in-time processes incur steeper direct losses. The following table summarizes average hourly direct costs from 2024 analyses:
IndustryAverage Cost per Hour
Automotive$2.3 million
Fast-Moving Consumer Goods$36,000
General Enterprises (large)$300,000+
These estimates derive from lost production value and repair outlays, with automotive costs doubling since 2019 due to supply chain integration. Notable incidents illustrate scale: Meta's 2024 outage resulted in nearly $100 million in direct loss from suspended and user access. Significant outages for other firms averaged $2 million per hour in 2025 reports, encompassing recovery hardware, software patches, and compensation. Such data underscores that direct costs compound rapidly beyond the first hour, as initial fixes often require extended vendor support and forensic analysis.

Operational and Productivity Losses

Operational downtime disrupts processes, compelling organizations to suspend , , or until systems are restored. In , for example, unplanned equipment failures can halt lines, resulting in zero output during outage periods and cascading delays in supply chains. Deloitte analysis indicates that such unplanned downtime contributes to an estimated $50 billion in annual industry-wide losses, primarily through foregone operational capacity. Poor practices, which exacerbate downtime frequency, further erode asset productive capacity by 5% to 20%, directly diminishing operational throughput. Productivity losses manifest as employee time and reduced , with workers unable to access critical tools, , or during outages. Ivanti's 2025 research, surveying over 3,300 IT professionals and end users, found that office workers face an average of 3.6 tech interruptions and 2.7 security-related disruptions per month, leading to nearly $4 million in annual lost for a typical 2,000-employee organization. In sectors like healthcare, Ponemon Institute's 2024 study on cyber insecurity reported average user time and losses of $995,484 per significant incident, reflecting the direct of unavailability on staff output. These disruptions often compound through task backlogs and requirements, sustaining deficits beyond the outage duration. Frequent or prolonged downtime also induces secondary productivity drags, such as employee , context-switching inefficiencies, and elevated rates upon resumption. Cockroach Labs' 2024 State of Resilience report noted that recurrent outages increase workloads from missed deadlines for 39% of respondents, accelerating and long-term output declines. Empirical breakdowns in Ponemon studies consistently allocate 20-40% of total outage costs to user impacts, underscoring the non-trivial share attributable to underutilization rather than solely infrastructural failures.

Long-Term and Sector-Specific Effects

Prolonged downtime episodes often result in enduring , eroding customer trust and leading to diminished that persists beyond immediate recovery. According to a by the Uptime Institute, one in five organizations experiencing serious outages reported significant reputational harm alongside financial losses, with recovery timelines extending months due to sustained customer attrition. This damage manifests in higher customer acquisition costs and potential erosion, as evidenced by empirical studies showing IT failures correlate with negative abnormal returns for affected firms, averaging declines that reflect investor perceptions of operational vulnerability. In the financial sector, long-term consequences include heightened regulatory oversight and legal liabilities from data integrity breaches during outages, potentially amplifying compliance costs and altering trading behaviors. For instance, failures in payment systems not only incur immediate revenue shortfalls but also foster long-term skepticism among clients, prompting shifts to competitors and necessitating substantial investments in fortified infrastructure. Healthcare systems face amplified risks of adverse patient outcomes from disrupted care technologies, with a 2025 study on widespread failures indicating commensurate negative effects on clinical operations, including delayed treatments and elevated error rates that contribute to ongoing litigation and insurance premium hikes. Such incidents can erode public confidence in providers, leading to patient diversion and strained resource allocation over years, particularly amid rising ransomware threats targeting critical infrastructure. Transportation networks experience cascading operational inefficiencies post-outage, including regulatory fines and labor disruptions that compound into multi-year supply chain realignments. Internet outages in this sector, as documented in 2023 analyses, result in unscheduled downtimes yielding steep fees and workforce idle time, often prompting infrastructure overhauls to mitigate recurrent vulnerabilities. These effects underscore sector interdependence, where initial failures propagate into prolonged economic drags via delayed and eroded reliability perceptions.

Notable Outages

Pre-Internet Era Examples

One prominent example of pre-Internet era downtime was the , which struck on November 9 at approximately 5:16 p.m. EST, triggered by the overload and subsequent tripping of a 230-kilovolt near Plant in , , due to a malfunction amid high demand and inadequate monitoring. This initiated a across interconnected grids, ultimately disrupting power to about 30 million people over an 80,000-square-mile area spanning eight U.S. states (, , , , , , and parts of Pennsylvania and New Jersey) and . The outage lasted up to 13 hours in some regions, halting subways (stranding 600,000 passengers in New York City alone), elevators, and traffic systems, while causing no direct fatalities but exposing vulnerabilities in grid coordination and leading to the creation of the Northeast Power Coordinating Council for improved reliability standards. Another significant incident was the blackout of 1977, occurring on July 13 amid a and economic strain, initiated by lightning strikes on transmission lines from the Indian Point nuclear plant and subsequent failures in protective equipment. The event plunged and surrounding areas into darkness for about 25 hours, affecting over 9 million residents and triggering widespread , including at more than 1,600 stores, over 1,000 fires (many arson-related), and approximately 3,700 arrests. Unlike the 1965 blackout, which saw relatively orderly public response, the 1977 event resulted in 55 injuries to police, 80 to firefighters, and extensive property damage estimated in tens of millions, highlighting socioeconomic factors exacerbating downtime impacts and prompting investments in backup generation and faster restoration protocols. Pre-Internet telecommunications downtimes were less documented in scale compared to power failures, as networks operated with analog switches and limited interconnection, but overloads during peak events occasionally caused regional disruptions; for instance, high-traffic failures in urban exchanges during the 1960s and 1970s stemmed from mechanical relay limitations rather than systemic cascades. These incidents underscored early challenges in scaling infrastructure without digital oversight, often resolved manually within hours, though they prefigured later vulnerabilities revealed in events like the 1990 AT&T long-distance collapse.

Major 21st-Century Incidents

One of the earliest significant disruptions occurred on February 15, 2008, when Amazon's Simple Storage Service (S3) experienced a multi-hour outage due to internal server communication failures across its data centers, lasting approximately two hours and affecting numerous websites and applications dependent on the service for and retrieval. This event highlighted early vulnerabilities in nascent cloud infrastructure, impacting startups and enterprises worldwide by rendering hosted content inaccessible. In April 2011, Sony's (PSN) suffered a prolonged outage following a intrusion that compromised of approximately 77 million users, leading to a shutdown lasting 23 to 24 days from to mid-May to investigate and restore security. The breach exposed names, addresses, and possibly details, resulting in substantial financial losses estimated in the tens of millions and regulatory scrutiny, underscoring risks of centralized vulnerabilities. Research In Motion (RIM), maker of devices, faced a global service outage from October 10 to October 14, 2011, triggered by a core switch failure in its data centers, disrupting email, messaging (including ), and browser services for up to 70 million users across multiple continents for nearly four days. This incident, compounded by backlog delays upon restoration, eroded user trust in the platform's reliability at a time of intensifying competition. A large-scale DDoS attack on DNS provider Dyn on October 21, 2016, exploited the to overwhelm servers, causing intermittent outages lasting several hours and disrupting access to major websites including , , , and , primarily on the U.S. East Coast. The event exposed dependencies on single DNS providers and amplified traffic to alternative networks, affecting millions of users and prompting industry-wide discussions on . Amazon Web Services (AWS) encountered a notable S3 outage on February 28, 2017, stemming from a in a debugging command that inadvertently triggered cascading failures in the billing system's update process, rendering the service unavailable for about four hours and impacting dependent applications worldwide. This disruption led to millions in estimated lost revenue for affected businesses and reinforced the need for rigorous in operations. Similarly, a March 14, 2019, outage at lasted around 14 to 22 hours due to server configuration changes, halting access to the platform, , and associated services for hundreds of millions of users globally and marking one of the largest disruptions recorded.

Recent Outages (2020s)

On June 8, 2021, provider experienced a global outage lasting approximately one hour, triggered by an undiscovered activated during a customer's routine update. The incident disrupted access to numerous high-profile websites, including , , and , highlighting vulnerabilities in infrastructure where a single point of failure cascaded across dependent services. A more extensive disruption occurred on October 4, 2021, when 's platforms—, , and —suffered a six-hour outage affecting over 3.5 billion users worldwide. The root cause was a faulty command during backbone router that severed all interconnections and BGP announcements, rendering internal tools inaccessible and complicating efforts. This event exposed risks in self-hosted DNS and over-reliance on interconnected global networks, with estimated economic losses exceeding $100 million for alone. In July 2024, a defective content update to CrowdStrike's Falcon sensor software caused widespread crashes on approximately 8.5 million Windows devices globally, paralyzing airlines, hospitals, and financial systems for up to several days in some cases. The update introduced an out-of-bounds memory read error in kernel-mode drivers, requiring manual remediation on affected machines since automated recovery was impossible due to boot loops. Recovery varied, with about 99% of sensors restored by late July, but the incident underscored single-vendor dependencies in endpoint detection and response tools, amplifying impacts through interactions with Microsoft Windows. Amazon Web Services (AWS) faced a significant outage on October 20, 2025, stemming from DNS resolution failures in multiple regions, which disrupted services like , , and for several hours. The issue, affecting core infrastructure components, led to cascading failures in dependent applications and highlighted ongoing challenges with DNS propagation in hyperscale cloud environments, though full recovery was achieved by evening. These events collectively illustrate persistent risks from software defects and configuration errors in modern IT ecosystems, despite redundancy measures.

Mitigation and Response Strategies

Proactive Planning and Redundancy

Proactive planning for minimizing downtime encompasses systematic risk assessments, capacity forecasting, and scheduled preventive maintenance to preempt failures rather than react to them. Organizations conduct thorough audits to identify vulnerabilities, such as single points of failure in power supplies or network links, enabling the prioritization of interventions like upgrading aging hardware before degradation leads to outages. Capacity planning involves analyzing historical usage data and projecting future demands using tools like predictive analytics, ensuring infrastructure scales to handle peak loads without overload; for example, data centers forecast resource needs to maintain availability targets exceeding 99.99%, avoiding scenarios where insufficient provisioning causes cascading failures. Scheduled maintenance, performed during low-traffic periods, addresses wear on components like servers and cooling systems, with evidence from industrial applications showing it can cut unplanned downtime by shifting repairs from reactive firefighting to controlled intervals. Redundancy strategies build on planning by duplicating critical components to enable automatic , thereby isolating faults and preserving service continuity. redundancy, such as configurations where spare units back up primaries (e.g., extra power supplies or fans), ensures that the failure of one element does not propagate; documentation highlights how such clusters allow redundant servers or databases to execute identical tasks, reducing mean time to recovery to seconds in well-designed systems. redundancy employs multiple paths and protocols like VRRP for router , while data replication across geographically dispersed sites guards against site-wide disruptions, as seen in architectures where synchronous mirroring achieves near-zero during switches. Empirical analyses of data centers reveal that facilities with comprehensive redundancy, including multiple availability zones, experience shorter outage durations compared to non-redundant setups, with Ponemon Institute surveys linking such measures to fewer extended facility-wide incidents. Integrating proactive planning with yields compounded , as ongoing feeds into redundancy activation; for instance, real-time triggers load balancing across redundant nodes, preventing minor issues from escalating. However, redundancy incurs upfront costs—often 20-50% higher for duplicated —and demands rigorous testing to avoid common pitfalls like correlated failures from shared dependencies, underscoring the need for first-principles design that verifies independent operation of backups. In telecommunications hierarchies, models optimizing redundancy levels demonstrate that balancing replication depth against repair speeds minimizes cumulative downtime more effectively than isolated tactics.

Incident Response Protocols

Incident response protocols provide a systematic framework for organizations to detect, analyze, contain, eradicate, recover from, and learn from IT outages or downtime events, aiming to minimize duration and impact on operations. These protocols are essential in , where unplanned downtime can cost enterprises an average of $9,000 per minute according to empirical analyses of major incidents. The National Institute of Standards and Technology (NIST) outlines a lifecycle in Special Publication 800-61 Revision 2, emphasizing coordination across phases to handle incidents ranging from hardware failures to cyber-induced outages. The preparation phase establishes foundational elements, including forming a cross-functional incident response team with defined roles such as incident commander, technical analysts, and communication leads; developing communication plans for internal stakeholders and external parties; and deploying monitoring tools for early detection of anomalies like performance degradation or error spikes. Organizations must conduct regular tabletop exercises and simulations to test these elements, as unprepared teams can extend recovery times by factors of 2-5 based on post-incident reviews of real-world outages. Tools such as automated alerting systems and redundant logging are prioritized to enable rapid identification without relying on manual checks. Detection and analysis involve continuous monitoring to identify downtime indicators, followed by to classify severity—e.g., distinguishing partial service degradation from —and root cause assessment using logs, traces, and diagnostic scripts. NIST recommends correlating data from multiple sources to avoid false positives, which can delay response; for instance, in environments, integrating metrics from providers like AWS or dashboards facilitates this. Empirical data from incident reports show that teams with automated detection reduce time to detect (MTTD) to under 30 minutes in mature setups. Containment protocols focus on short-term stabilization to prevent outage propagation, such as isolating affected systems via firewalls, failover to backups, or traffic rerouting, while preserving evidence for analysis. Eradication addresses the underlying cause, like patching software vulnerabilities or replacing faulty hardware, ensuring complete removal to prevent recurrence. Recovery then restores full operations through controlled rollbacks or phased reintroductions, with monitoring to verify stability before declaring resolution. The SANS Institute framework aligns closely, stressing evidence preservation during containment to support forensic review. Post-incident activities include a structured review to document timelines, decisions, and outcomes, calculating metrics like mean time to recovery (MTTR) and identifying gaps—such as inadequate redundancy that prolonged the 2021 outage affecting global sites for over an hour. These reviews feed into iterative improvements, with high-performing organizations conducting them within 72 hours to institutionalize lessons. Adherence to such protocols has been shown to cut downtime by up to 50% in sectors like , where regulatory mandates enforce similar structures.

Advanced Technologies for Avoidance

Advanced technologies for avoiding downtime leverage , , and distributed architectures to anticipate failures, enhance system resilience, and enable real-time interventions before disruptions occur. powered by AI analyzes sensor data and historical patterns to forecast equipment or system failures with high accuracy, reducing unplanned outages by up to 50% in and IT environments according to studies on industrial applications. For instance, models trained on service metrics can generate risk scores for IT components, allowing preemptive resolutions that prevent outages in enterprise networks. AIOps platforms integrate AI for anomaly detection and root-cause analysis in IT operations, predicting network outages by processing vast datasets from logs, metrics, and environmental factors faster than traditional methods. In utility grids, AI algorithms have demonstrated the ability to forecast weather-induced outages hours in advance, enabling operators to reroute power and mitigate cascading failures. These systems outperform rule-based by adapting to novel patterns, though their effectiveness depends on high-quality training data to avoid false positives that could lead to unnecessary interventions. Fault-tolerant designs incorporate and error-correction mechanisms to sustain operations amid or software faults, such as through replication and self-checking logic that masks errors without perceptible interruption. Modern implementations in data centers use predictive platforms that detect impending failures in , achieving near-zero downtime for mission-critical workloads by automatically isolating and replacing faulty nodes. Unlike basic high-availability setups, true fault tolerance employs techniques like , where spare components ensure continuity even during active failures, as validated in enterprise-scale deployments. Edge computing decentralizes processing to devices near data sources, minimizing and single points of failure by enabling local that reduces reliance on centralized clouds prone to outages. This approach allows analytics on sensors for equipment health, cutting detection times for issues from minutes to seconds and preventing downtime in remote or distributed systems like floors. Combined with networks and , edge deployments have been shown to eliminate -induced disruptions in applications, supporting without full system halts. However, edge solutions require robust to counter distributed vulnerabilities that could amplify localized faults into broader incidents.

Debates and Controversies

Cloud vs. On-Premises Reliability

Cloud computing providers typically offer service level agreements (SLAs) guaranteeing 99.5% to 99.99% uptime, translating to potential annual downtime ranging from 4.38 hours to 43.8 hours per service, with credits issued for breaches. These commitments leverage provider-scale , such as multi-region data centers and automated , which independent analyses describe as rendering cloud infrastructure "orders of magnitude less fragile" than typical enterprise on-premises setups. On-premises systems, by contrast, lack inherent SLAs and depend entirely on internal management, where underinvestment in or expertise often results in higher to failures, power disruptions, or errors. Empirical assessments highlight cloud's edge in engineered reliability, as providers invest in specialized operations teams and global that surpass most organizations' in-house capabilities. For instance, (AWS) maintains historical uptime exceeding 99.99% for core services despite incidents like the February 28, 2017, S3 outage in the US East region, which stemmed from in billing system updates and affected dependent services for hours. On-premises environments, while granting full control to mitigate specific risks, face elevated downtime from localized failures without comparable ; NIST notes that such systems avoid external dependencies but require consumers to handle all contingency planning, often leading to inconsistent outcomes. Critics argue introduces systemic risks through vendor concentration, where a single provider outage cascades across customers, as seen in the 2017 AWS event impacting sites from to . trends—moving workloads back on-premises—stem partly from perceived reliability gaps during high-profile disruptions, though data indicates these are outliers against baseline . On-premises reliability hinges on rigorous internal practices, yet many enterprises report fragile setups due to resource constraints, underscoring that 's advantages accrue primarily to those architecting for rather than assuming provider infallibility. Provider self-reported metrics warrant scrutiny for , but neutral evaluations like those from Forrester affirm 's superior when dependencies are minimized.

Regulatory Influences on Downtime

Regulations in critical sectors mandate measures to enhance system , , and incident reporting, thereby influencing organizational strategies to minimize downtime. These frameworks, often developed in response to historical outages, require entities to implement , testing protocols, and mechanisms, while imposing penalties for failures that compromise . For instance, non-compliance with outage-related requirements can result in fines, as seen in regulatory enforcement actions against providers for disruptions affecting . In the United States financial markets, the 's Regulation , adopted on November 19, 2014, applies to self-regulatory organizations, , clearing agencies, and alternative trading systems that provide functionality essential to market operations where alternatives are limited. It mandates policies and procedures to ensure adequate systems capacity, integrity, resiliency, availability, and security, including regular testing of backup systems and prompt recovery from disruptions. entities must report outages and systems intrusions to the within 24 hours, with quarterly reviews and annual updates to compliance programs, fostering proactive downtime mitigation but also increasing operational overhead. Telecommunications providers face (FCC) rules under 47 CFR Part 4, which establish thresholds for reporting disruptions, such as outages lasting at least 30 minutes that block 90,000 or more calls or result in significant loss of transmission capacity. These include mandatory notifications via the Network Outage Reporting System (NORS) for impacts on services or interconnected VoIP, compelling carriers to maintain resilient networks and notify affected public safety answering points expeditiously. In healthcare, the Health Insurance Portability and Accountability Act (HIPAA) Security Rule requires covered entities to implement safeguards ensuring the availability of electronic (ePHI), including contingency plans for and periodic evaluation of system protections against disruptions. Internationally, the European Union's NIS2 Directive (EU) 2022/2555, effective from January 16, 2023, expands on the original framework by requiring operators of in sectors like , , and digital to adopt risk-management measures, including and rapid incident reporting within 24 hours for significant disruptions. This influences downtime by broadening accountability to s and imposing supply chain security obligations, aiming to bolster against and physical threats that could cause outages. Such regulations collectively drive empirical improvements in uptime through enforced standards, though critics argue they may exacerbate concentration risks in shared without addressing root causes like software flaws.

Overhyped Media Narratives vs. Empirical Risks

Media coverage of high-profile IT outages often amplifies narratives of systemic fragility and imminent catastrophe, as exemplified by the extensive reporting on the October 4, , which halted services across , , and for about six hours, affecting an estimated 3.5 billion users and prompting discussions of overdependence on centralized platforms. Such events receive disproportionate attention relative to their rarity; the Uptime Institute's 2025 Annual Outage Analysis reports that only 53% of operators experienced an outage in the preceding three years, with impactful incidents most commonly traced to power failures rather than cascading digital breakdowns. A historical benchmark is the Y2K transition, where anticipatory media portrayals of potential global computer meltdowns fueled preparations costing over $300 billion worldwide, yet actual disruptions proved negligible, with isolated failures largely confined to non-critical systems and preempted by remediation efforts. Empirical data underscores that routine causes dominate downtime risks: human errors, particularly procedural deviations, rose to contribute significantly to outages in 2024-2025, while IT and networking faults accounted for 23% of cases, far outpacing the hyped existential threats. Cyber incidents, though increasing—nearly doubling in major outages from 2021 to 2024—remain a minority driver, often contained without the widespread fallout suggested by sensational accounts. This divergence reflects incentives in mainstream reporting for dramatic framing to drive engagement, potentially skewing perceptions away from verifiable trends like declining overall outage frequency and robust average uptimes exceeding 99.95% in enterprise environments. Real risks accrue more from cumulative, avoidable lapses—such as the 51% of outages deemed preventable per IT surveys—than from the infrequent spectacles that dominate headlines, with tools like reducing annual downtime by up to 40% when deployed. Despite rising disruptions reported by 84% of organizations over two years, these seldom escalate to economy-wide , highlighting media's tendency to overstate against evidence of infrastructural .

References

  1. [1]
    Downtime - an overview | ScienceDirect Topics
    Down time is defined as the period during which equipment is in a failed state, encompassing the time from when a fault occurs until the system is restored ...
  2. [2]
    What is uptime and downtime in computing? - TechTarget
    Jun 22, 2023 · Uptime is a measure of how long a computer or service is on and available. Downtime is the measure of how long it is not available.
  3. [3]
    What is Downtime? | Answer from SUSE Defines
    Feb 20, 2018 · Downtime is a computer industry term for the time during which a computer or IT system is unavailable, offline or not operational.
  4. [4]
    Downtime - an overview | ScienceDirect Topics
    Downtime refers to any period when a computer system is not operational, typically due to hardware or software issues or power failure.
  5. [5]
    Downtime: Causes, Costs and How to Minimize It - Unitrends
    Mar 22, 2021 · Downtime is when production halts due to unavailability, caused by human error, hardware/software failure, cyber threats, and natural disasters.Missing: definition | Show results with:definition
  6. [6]
    Downtime: Understanding and Minimizing Outages - Zenduty
    Sep 23, 2025 · Downtime refers to periods when systems, whether it's a server, network, or computer are unavailable for use.Share This Article · How To Calculate Downtime... · Strategies To Minimize...
  7. [7]
    What Is Downtime? Definitions and Best Practices - Beekeeper
    Sep 10, 2020 · We define downtime as a time when employees are involuntarily idle in their work tasks, due to equipment or technological malfunction, project bottlenecks.
  8. [8]
    Understanding Downtime: Causes, Effects, and Solutions - shoplogix
    Jun 6, 2024 · Downtime in lean manufacturing is when production equipment isn't operating as intended, causing a temporary halt or reduction in output.
  9. [9]
    What is Downtime? - PagerDuty
    Downtime is best described as a period in which a system, device, or application's core services, both internal and/or external, are unavailable or idle.
  10. [10]
    IT downtime | What causes it and how to prevent it
    What causes IT downtime? · 1. Hardware and network failure · 2. Software issues · 3. Third-party service failure · 4. Human error · 5. Disasters.<|separator|>
  11. [11]
    DOWNTIME definition in American English - Collins Dictionary
    1. the time during which a machine, factory, etc. is shut down for repairs or the like 2. the time during which a computer or computer system is down, or ...Missing: reliable | Show results with:reliable
  12. [12]
  13. [13]
    Manufacturing Downtime: Definition, Stats & More | TWI Institute
    In manufacturing, downtime refers to any period of time in which production has stopped, either facility-wide or on one piece of equipment.
  14. [14]
    What Is Manufacturing Downtime? | Limble CMMS
    This brings us to the critical concept of downtime—a period during which a system is unavailable, disrupting the normal course of production.
  15. [15]
    The Costs of Planned vs Unplanned Downtime - CockroachDB
    Mar 13, 2024 · The technical definition of downtime is “a period of time when technology services are unavailable to users”. This elegant simplicity, however, ...Two Types Of Downtime · Types Of Downtime Costs · The Financial Cost Of...<|control11|><|separator|>
  16. [16]
    How to Minimize Downtime in IT Operations - Splashtop
    Sep 30, 2025 · We can typically fit downtime into two categories: planned and unplanned. While each can still impact business operations, they require ...
  17. [17]
    Understanding Planned Downtime and How to Manage ... - PagerDuty
    Planned vs.​​ Unplanned downtime (also known as unscheduled downtime) is when a lapse in operations occurs because of an unplanned machine or server error. It's ...
  18. [18]
    What is Downtime? Prevention Strategies for Uninterrupted Operations
    Oct 3, 2025 · Downtime, a common occurrence in various industries, can be classified into different types: planned, unplanned, and partial. Understanding ...<|control11|><|separator|>
  19. [19]
    Outage Classifications - SOTS - TL 9000
    Outage Classifications ; FACILITY RELATED, Outages due to the loss of facilities that isolates a network node from the remainder of the communications network.<|separator|>
  20. [20]
    [PDF] TL 9000 Quality Management System Measurements Handbook ...
    This document provides product category tables for TL 9000, used to classify products by primary function for reporting measurements. Products are classified ...
  21. [21]
    (PDF) Modeling downtime severity of telecommunication networks ...
    May 15, 2023 · The severity of daily downtime was categorized into 5 categories based on duration. Results indicate that the majority (n=905) of daily network ...
  22. [22]
    What Is Network Outage? Types & Best Practices - IO River
    Jul 25, 2025 · Types of Network Outages · 1. Total Outage · 2. Partial Outage · 3. Latency-Related Outage.What is a Network Outage? · Types of Network Outages
  23. [23]
    NSF Shapes the Internet's Evolution - National Science Foundation
    Jul 25, 2003 · In a short time, the network became congested and by 1988 its links were upgraded to 1.5 megabits per second. ... NSFNET forced the Internet ...Missing: outages 1980s
  24. [24]
    Morris worm - Wikipedia
    The Morris worm or Internet worm of November 2, 1988, is one of the oldest computer worms distributed via the Internet, and the first to gain significant ...
  25. [25]
    Internet History of 1980s
    The upgrade of the NSFNET backbone to T1 completes and the Internet starts to become more international with the connection of Canada, Denmark, Finland, France, ...
  26. [26]
    The Internet: evolution and growth statistics - Stackscale
    May 17, 2023 · Internet users growth from 1995 to 2022 ; 1998, 147 million users ; 1999, 248 million users ; 2000, 361 million users ; 2001, 513 million users.The Internet: the network of... · Open Internet and Net Neutrality<|separator|>
  27. [27]
    The 1990 AT&T Network Outage - by Jeffrey Rubel
    Jul 19, 2024 · On January 15th, 1990, sixty thousand people lost their telephone service and seventy million phone calls went uncompleted.Missing: major | Show results with:major
  28. [28]
    PART ONE: Crashing the System </HEAD> - MIT
    On January 15, 1990, AT&T's long-distance telephone switching system crashed. This was a strange, dire, huge event. Sixty thousand people lost their ...
  29. [29]
    DDoS Attacks 25th Anniversary: A Wake-Up Call
    Sep 29, 2021 · On September 06 1996, New York's oldest commercial internet provider, Panix, experienced the first known SYN flood DDoS attack. A quarter of a ...
  30. [30]
    New York's Panix Service Is Crippled by Hacker Attack
    Sep 14, 1996 · A hacker intent on shutting Panix down successfully did just that, by bombarding the service provider's servers with a flood of phony connection requests.Missing: details | Show results with:details
  31. [31]
    Net Outage: The Oops Heard 'Round the World - WIRED
    Apr 25, 1997 · Apr 25, 1997 6:03 PM. Net Outage: The Oops Heard 'Round the World. Parts of the Net went south for a few hours on Friday. The reason? A router ...
  32. [32]
    Human Error Cripples the Internet - The New York Times Web Archive
    July 17, 1997. Human Error Cripples the Internet. By PETER WAYNER. C ompanies, computers and people started disappearing from the Internet at 2:30 a.m. ...
  33. [33]
    Tech Time Warp: Email Outage Chaos in July 1997 - Smarter MSP
    Jul 21, 2017 · The world got one of its first tastes of Internet dependency on July 17, 1997, when a small human error resulted in a major email outage. A ...Missing: InterNIC | Show results with:InterNIC<|separator|>
  34. [34]
    Visualized: The Growth of Global Internet Users (1990–2025)
    May 4, 2025 · By the beginning of the 21st century, internet usage had crossed 361 million people (6% of the population in 2000), and the momentum only ...
  35. [35]
    History of the internet: a timeline throughout the years - Uswitch
    Aug 5, 2025 · The history of broadband from the '70s until today. From dial-up to broadband, read up on developments in broadband over time.
  36. [36]
    How the Internet Turned Bad. The 1990s Vision Failed - Medium
    Apr 20, 2018 · The peer-to-peer structure of the Internet and the services provided over it did not scale gracefully. The idea of a “dumb network” of fully ...
  37. [37]
    Azure vs AWS Reliability: Most Reliable Cloud Platform [2025]
    Oct 15, 2024 · Uptime percentages of their core services exceed 99.99% on average monthly for AWS and Azure.
  38. [38]
    The 10 Biggest Cloud Outages Of 2020 - CRN
    Dec 1, 2020 · Microsoft Azure, March 3. A six-hour outage, starting at 9:30 a.m. ET, struck the U.S. East data center for Microsoft's Azure cloud, limiting ...<|separator|>
  39. [39]
    5 Cloud Outages That Shook the World in 2020 - Spiceworks
    Dec 29, 2020 · On December 14, 2020, Google Cloud experienced a widespread outage that interrupted services, including YouTube, Google Workspace, and Gmail.
  40. [40]
    Uptime: Frequency and severity of data center outages on the decline
    Apr 5, 2024 · The overall frequency and severity of data center outages are on the decline, according to a new report from the Uptime Institute.
  41. [41]
    37 Cloud Computing Statistics, Facts & Trends for 2025 - Cloudwards
    Apr 16, 2025 · 10% of all reported outages in 2022 were caused by a problem with a third-party provider such as SaaS or a public cloud. For comparison, 54% of ...
  42. [42]
    Examples of Azure Outages & 7 Tips to Survive the Next One
    Aug 29, 2025 · Notable Azure Outages. July 2024 DDoS Attack. On July 30, 2024, Microsoft Azure suffered a major service disruption caused by a distributed ...
  43. [43]
    Takeaways From The Uptime Institute's Annual Outage Analysis ...
    Jul 3, 2024 · According to the Uptime Institute's study, direct and indirect human error contributes to approximately 66% to 80% of all downtime incidents.
  44. [44]
    Most Common Causes of Data Center Outages - Newtech Group
    Human error is a significant contributor to data center outages, accounting for approximately 70% of all problems. This can range from simple mistakes like ...
  45. [45]
    Uptime Institute's 2022 Outage Analysis Finds Downtime Costs and ...
    Nearly 40% of organizations have suffered a major outage caused by human error over the past three years. Of these incidents, 85% stem from staff failing to ...
  46. [46]
    Human Errors Remain Main Cause of Data Center Power Outages
    May 8, 2025 · Human errors caused a major outage in 40 percent of organizations in the past three years. In 58 percent of those cases, a procedure was not ...
  47. [47]
    Top 10 Technology Failure Examples That Shook the World
    Sep 3, 2024 · In February 2017, Amazon Web Services (AWS) experienced a major outage in its S3 storage service. The outage was caused by human error during ...
  48. [48]
    10 Cases of Certificate Outages Involving Human Error
    Jan 8, 2024 · On February 3, 2019, Microsoft Teams experienced a three-hour outage due to an expired authentication certificate. The incident left its 20 ...
  49. [49]
    Major tech outages in recent years | Reuters
    Jul 19, 2024 · Meta-owned social media platforms Facebook, WhatsApp and Instagram went dark for six hours on October 4, 2021, with 10.6 million users reporting ...
  50. [50]
    Six causes of major software outages - and how to avoid them
    Aug 8, 2024 · Human error remains one of the leading causes of tech outages. This can include mistakes made during routine maintenance, misconfigurations, or ...
  51. [51]
  52. [52]
    Hardware Failures: Mitigating Risks in Modern Data Centers:
    Jan 10, 2025 · Hardware failures are among the leading causes of data center outages, accounting for 45% of downtime incidents globally.
  53. [53]
    The Causes of IT and Server Hardware Failure - BCDVideo
    May 17, 2022 · Hardware failure is the biggest culprit of small and mid-sized business (SMB) downtime and data loss.
  54. [54]
    How do data centers deal with constant disk failure? - Server Fault
    Feb 18, 2024 · SSD hard drives have a annualized failure rate of 0.98% , HDD have 1.6%. This means if you have a data center of 600 disk: There is a (1 ...
  55. [55]
    How Much Do Hardware Failures Really Impact Your Uptime?
    Dec 17, 2024 · Expected Component Failures per Year (Across 1,000 Servers) ; Network Card, 2,000, 0.5% ; Chassis Fan, 15,000, 2% ; CPU Fan, 1,000, 2% ; Power ...
  56. [56]
    Top 10 IT Issues That Cause Downtime in Law Firms and How to ...
    Jul 29, 2024 · Hardware failures, such as server crashes and hard drive failures, are common causes of IT downtime. These failures can occur due to wear and ...
  57. [57]
    Networking errors pose threat to data center reliability
    May 8, 2025 · Configuration/change management failure: 50% · Third-party network provider failure: 34% · Hardware failure: 31% · Firmware/software error: 26% ...
  58. [58]
    Datacenter GPU service life can be surprisingly short — only one to ...
    Oct 24, 2024 · If GPUs and their memory keep failing at Meta's rate, then the annualized failure rate of these processors will be around 9%, whereas the ...
  59. [59]
    Six common causes of major software outages - SecurityBrief Australia
    Oct 3, 2024 · Six common causes of major software outages · 1. Software bugs: · 2. Cyberattacks: · 3. Spikes in demand: · 4. Back-up failures: · 5. Network issues:
  60. [60]
    Avoiding Outages and Preventing Widespread System Failures
    Aug 13, 2024 · Beyond code, configuration and data changes can lead to failures. An inability to treat these with the same care and robust processes can lead ...
  61. [61]
  62. [62]
    11 of the most costly software errors in history · Raygun Blog
    Jan 26, 2023 · 1. The Mariner 1 Spacecraft, 1962 · 2. The Morris Worm, 1988 · 3. Pentium FDIV Bug, 1994 · 4. Bitcoin Hack, Mt. Gox, 2011 · 5. EDS Child Support ...
  63. [63]
    The Most Famous DDoS Attacks - Corero Network Security
    Nov 26, 2024 · DDoS (distributed denial-of-service) attacks are responsible for more than 50% of attacks according to Verizon's 2024 Data Breach Investigations ...
  64. [64]
    Cyber Attacks Top Cause of IT Downtime for UK Businesses
    Oct 1, 2024 · Cyber incidents have overtaken hardware failures as the leading cause of IT downtime and data loss in U.K. businesses, with larger companies ...
  65. [65]
    Targeted by 20.5 million DDoS attacks, up 358% year-over-year
    Apr 27, 2025 · In the first quarter of 2025, we blocked 20.5 million DDoS attacks. For comparison, during the calendar year 2024, we blocked 21.3 million DDoS attacks.
  66. [66]
    2024 DDoS Attack Trends | F5 Labs
    Jul 16, 2024 · Looking at total incidents, we found that DDoS attacks more than doubled over 2023, exploding from just over 1,000 in 2022 to more than 2,100 a ...
  67. [67]
    8 largest IT outages in history - TechTarget
    Sep 19, 2024 · Learn about the eight largest IT outages in history and how to prepare for them.The Eight Largest It Outages... · 2. Amazon Web Services... · 8. Crowdstrike (2024)
  68. [68]
    Cyber DDoS Attacks and Data Breaches: 7 Biggest Cases
    Apr 7, 2025 · In 2018, GitHub faced the largest recorded DDoS attack in history, with traffic peaking at 1.35 terabits per second. GitHub, a platform for ...<|separator|>
  69. [69]
    DDoS Examples: 10 DDoS Attacks that Took the World by Storm
    Jul 7, 2023 · 10 Notable DDoS Attack Examples · Internet Archive Attack (2024) · Anonymous Sudan (2023-2024) · Microsoft Azure DDoS Attack (2023) · The AWS DDoS ...
  70. [70]
    The Devastating Business Impacts of a Cyber Breach
    May 4, 2023 · For example, ransomware attacks had a much bigger financial impact on the health care sector, with over $7.8 billion lost due to downtime alone ...
  71. [71]
    Top 25 Real World Case-Studies on Cyber Security Incidents?
    Another one of the biggest security attacks and data breaches in history is the Yahoo attack that caused the hacking of about 500 million Yahoo accounts.Missing: downtime | Show results with:downtime
  72. [72]
    11 Biggest Cybersecurity Attacks in History - Cobalt.io
    Jun 20, 2024 · 11. Real Estate Wealth Network Leak · 10. MOVEit Transfer Data Breach · 9. Log4J Vulnerability · 8. Colonial Pipeline Ransomware Attack · 6. Yahoo ...
  73. [73]
    Ransomware Attacks Targeting Industrial Operators Surge 46% in ...
    Jun 4, 2025 · Ransomware attacks jumped by 46% from Q4 2024 to Q1 2025, according to Honeywell's (Nasdaq: HON) new 2025 Cybersecurity Threat Report.Missing: firms | Show results with:firms
  74. [74]
    Significant Cyber Incidents | Strategic Technologies Program - CSIS
    This timeline records significant cyber incidents since 2006, focusing on cyber attacks on government agencies, defense and high tech companies, or economic ...
  75. [75]
    Impact of DDoS Attacks on Businesses | StormWall
    IT infrastructure downtime caused by DDoS attacks costs large businesses around $400 billion annually, according to analysts from Splunk and Oxford Economics.
  76. [76]
    Famous DDoS attacks | Biggest DDoS attacks | Cloudflare
    October 2023: Google mitigates 398 million RPS attack · August 2023: Gaming and gambling companies · June 2022: Google Cloud customer · November 2021: Azure.
  77. [77]
    Uptime Announces Annual Outage Analysis Report 2025
    May 6, 2025 · For 2025, the proportion of human error-related outages caused by failure to follow procedures rose by ten percentage points compared with 2024.Missing: hardware | Show results with:hardware
  78. [78]
    Common Threat to Data Loss: Natural Disasters - VaultTek
    Nov 21, 2024 · The National Oceanic and Atmospheric Administration (NOAA) reports that 75% of data centers in high-risk areas have experienced a power outage ...
  79. [79]
  80. [80]
    Extreme weather events and critical infrastructure resilience
    This study evaluates the economic impact of disruptions to seven critical infrastructure systems in Florida following Hurricane Irma's landfall in 2017. These ...
  81. [81]
    AI meets natural hazard risk: A nationwide vulnerability assessment ...
    Through their BI-LISA spatial analysis, they found that 62.1% of 8+ hour outages co-occurred with extreme climate related events such as heavy precipitation and ...
  82. [82]
    How are Data Centers Affected by Extreme Weather?
    Aug 2, 2022 · Extreme heat stresses data center cooling systems by making compressors, pumps, and fans, work harder, which increases the likelihood of ...
  83. [83]
    Optimal IT Environment: Ensure Equipment Reliability - Dataspan
    May 20, 2025 · Moisture also combines with dust in the air, obstructing the IT system's vents and fans. Meanwhile, very dry, low-humidity levels increase the ...3. Reduced Dust And... · Understanding Manufacturer... · The Cost Of Noncompliance
  84. [84]
  85. [85]
    [PDF] IMPLICATIONS OF EXTREME WEATHER EVENTS ON U.S ...
    With the move to coastal locations, data centers become more vulnerable to extreme weather that commonly impacts the coasts including hurricanes, tornadoes, and ...
  86. [86]
    MTBF, MTTR, MTTF, MTTA: Understanding incident metrics - Atlassian
    You can calculate MTTR by adding up the total time spent on repairs during any given period and then dividing that time by the number of repairs. So, let's say ...
  87. [87]
    System Outage Severity Rating - Uptime Institute
    The number of outages reported by the media has climbed steadily year on year, from 27 in our first year of reporting (2016) to 163 in 2019. Uptime Institute's ...
  88. [88]
    Understanding incident severity levels | Atlassian
    Incident severity levels help identify and prioritize issues for faster resolution. Learn where they fit in the incident lifecycle with our guide.
  89. [89]
    How to Calculate System Availability: Definition and Measurement
    Sep 24, 2024 · In a request-based approach, downtime is measured by the percentage of failed requests over a defined period rather than when a system is down.
  90. [90]
    Downtime Severity Levels (DSL) A way to measure Impact of ...
    The DSL system categorizes Data Center downtimes in five categories. CATEGORIES OF CAUSES OF DOWNTIME: Planned / Preventive Maintenance; Failure / Corrective ...
  91. [91]
    Incident Severity Levels 1-5 Explained - Splunk
    Sep 26, 2022 · Incident severity levels indicate how an incident impacts your customers, so you can prioritize and respond appropriately.
  92. [92]
    How To Calculate Uptime And Downtime? - Uptimia
    Apr 10, 2024 · Uptime percentage is calculated using a simple formula: Uptime percentage = (Total time - Downtime) / Total time x 100.
  93. [93]
    How to Define, Measure, and Report IT Service Availability That ...
    Jan 2, 2025 · A simple service availability definition is the percentage of time your service is available. One of the simplest ways to calculate it is based on two numbers.Missing: scope | Show results with:scope<|separator|>
  94. [94]
    What Is Mean Time between Failure (MTBF)? - IBM
    MTBF is calculated by dividing the total time of operation by the number of failures that occur during that time. The result is an average value that can be ...
  95. [95]
    What is Mean Time to Repair (MTTR)? - IBM
    Mean time to repair (MTTR) is a metric used to measure the average time it takes to repair a system or piece of equipment after it has failed.
  96. [96]
    What is SLA? - Service Level Agreement Explained - AWS
    It outlines metrics such as uptime, delivery time, response time, and resolution time. An SLA also details the course of action when requirements are not met, ...
  97. [97]
    What is an SLA? Best practices for service-level agreements - CIO
    A service-level agreement (SLA) defines the level of service expected from a vendor, laying out metrics by which service is measured, as well as remedies ...
  98. [98]
    What is a Cloud SLA? - DigitalOcean
    Sep 11, 2024 · A Service Level Agreement (SLA) acts as a safety net, typically guaranteeing uptime, outlining specific performance metrics, and detailing ...
  99. [99]
    SLA & Uptime calculator: How much downtime corresponds to 99.9 ...
    SLA level of 99.9 % uptime/availability results in the following periods of allowed downtime/unavailability: Daily: 1m 26s; Weekly: 10m 4.8s; Monthly: 43m 50s ...
  100. [100]
    Types of Service Level Agreement (SLA) Metrics - IBM
    SLAs describe the level of performance to be expected, how performance will be measured and repercussions if levels are not met.
  101. [101]
    Amazon Compute Service Level Agreement - AWS
    May 25, 2022 · AWS will use commercially reasonable efforts to make Amazon EC2 available for each AWS region with a Monthly Uptime Percentage of at least 99.99%.
  102. [102]
    Compute Engine Service Level Agreement (SLA) - Google Cloud
    The Covered Service will provide a Monthly Uptime Percentage to Customer per Network Service Tiers, as follows (the "Service Level Objective" or "SLO").<|separator|>
  103. [103]
    ITIC 2024 Hourly Cost of Downtime Report Part 1
    Sep 3, 2024 · Cost of Hourly Downtime Exceeds $300,000 for 90% of Firms; 41% of Enterprises Say Hourly Downtime Costs $1 Million to Over $5 Million.
  104. [104]
    .conf24: Splunk Report Shows Downtime Costs Global 2000 ...
    Jun 11, 2024 · The survey calculated the total cost of downtime for Global 2000 1 companies to be $400B annually, or 9 percent of profits, when digital environments fail ...
  105. [105]
    The True Cost of IT Downtime for Businesses in 2024 - DivergeIT
    Nov 20, 2024 · On average, downtime can cost $427 per minute for smaller businesses, with some downtime events causing $1 million per year in lost revenue and ...
  106. [106]
    The True Cost of an Hour's Downtime: An Industry Analysis
    Jul 4, 2024 · Every unproductive hour now costs automotive manufacturers a staggering $2.3 million. This figure represents a twofold increase from 2019, ...
  107. [107]
    [PDF] The True Cost of Downtime 2024 - Digital Asset Management
    At the bottom end, the costs of a lost hour are now $36,000 in Fast Moving Consumer Goods. At the top end, they are $2.3 million in the Automotive sector – or ...
  108. [108]
    The Cost of Downtime: Outages, Brownouts & Your Bottom Line
    Sep 2, 2025 · 93% of enterprises report downtime costs exceeding $300,000 per hour; For 48% enterprises, hourly costs exceed $1 million per hour; And for 23 ...
  109. [109]
    IT outages cost businesses $76M annually | CIO Dive
    Sep 18, 2025 · Significant downtime runs businesses $2 million for every hour operations are down, according to a study released by New Relic.
  110. [110]
    ITIC 2024 Hourly Cost of Downtime Part 2
    Sep 10, 2024 · Hourly downtime costs of $25,000; $50,000 or $75,000 (exclusive of litigation or civil and even criminal penalties) may be serious enough to put ...
  111. [111]
    Predictive Maintenance Solutions | Deloitte US
    Poor maintenance strategies can reduce an asset's overall productive capacity by 5% to 20%1. Recent studies also show that unplanned downtime is costing ...<|separator|>
  112. [112]
    Tech Disruptions Cost Companies Millions of Dollars in Lost ... - Ivanti
    Sep 10, 2025 · Office workers already endure 3.6 tech interruptions and 2.7 security update disruptions per month. This equates to nearly $4 million in lost ...
  113. [113]
    The 2024 Study on Cyber Insecurity in Healthcare: The Cost and ...
    Oct 17, 2024 · Users' idle time and lost productivity because of downtime or system performance delays decreased from $1.1 million in 2023 to $995,484 in 2024.
  114. [114]
    “The State of Resilience 2025” Reveals the True Cost of Downtime
    Oct 29, 2024 · ... hardware failures, severe traffic spikes, network issues, and third-party software incidents like the unprecedented CrowdStrike outage. At ...Missing: causes 2023-2025<|separator|>
  115. [115]
    Effects of information technology failures on the market value of firms
    Aug 9, 2025 · H1: IT failures will result in negative abnormal returns for the firm. Type of IT Failure: Operating vs. Implementation. In this study, we diffe ...
  116. [116]
    The True Cost Of Payment System Downtime: Can Your Business ...
    Nov 7, 2024 · Not only do payment system outages often result in lost revenue, but they also go as far as tarnishing brand reputations and causing long-term ...
  117. [117]
    The Cost of Downtime: Beyond Lost Revenue | Power Partners Group
    Aug 1, 2024 · For sectors like finance and healthcare, downtime can lead to data corruption and security breaches, resulting in legal liabilities and ...
  118. [118]
    Patient Care Technology Disruptions Associated With the ... - NIH
    Jul 19, 2025 · These findings suggest that widespread technology failures affecting health care infrastructure may have commensurate negative impacts on patient care systems.
  119. [119]
    [PDF] The impact of unplanned system outages on critical infrastructure ...
    Additionally, the healthcare system and enterprises operating within. CNI sectors are facing a surge of cyberattacks, particularly ransomware attacks (Devi, ...
  120. [120]
    How Internet Outages Impact Transportation - Cisco Blogs
    Feb 7, 2023 · Downtime in certain areas of the transportation sector can be expensive, resulting in steep regulatory fees and labor costs. Unscheduled ...<|separator|>
  121. [121]
    How internet blackouts affect information flows in organizations
    Sector-specific cascade effects with regard to the transport and health sector. The generalizability of the Building Block Model was tested by establishing ...
  122. [122]
    The Great Northeast Blackout | November 9, 1965 - History.com
    Mar 4, 2010 · The blackout was caused by the tripping of a 230-kilovolt transmission line near Ontario, Canada, at 5:16 p.m., which caused several other ...
  123. [123]
    [PDF] Final Blackout Report Chapters 7-10
    November 9, 1965: Northeast Blackout​​ This disturbance resulted in the loss of over 20,000 MW of load and affected 30 million people.
  124. [124]
    Power Failure of 1965 | Research Starters - EBSCO
    Within ten minutes, an extensive 80,000-square-mile area lost electricity, stranding over 600,000 subway passengers and causing widespread disruption in urban ...
  125. [125]
    NYC in Chaos | American Experience | Official Site - PBS
    On the night of July 13, 1977, lightning strikes took out several critical power lines, causing a catastrophic power failure and plunging the New York City area ...
  126. [126]
    The blackout that nearly broke New York—and the logo that saved it
    Apr 22, 2025 · A 25-hour blackout, triggered by lightning striking key transmission lines, led to widespread looting, riots, and more than a thousand fires.
  127. [127]
    New York City blackout of 1977 | Research Starters - EBSCO
    Notably, the effects of the blackout extended beyond immediate destruction; it reportedly led to a spike in births approximately nine months later, as many ...
  128. [128]
    [PDF] I 1.15y26 - OSTI
    The occurrence of the July 1977 New York City blackout provided a rare, hopefully not-to-be-repeated, opportunity for collecting extensive and valuable data ...
  129. [129]
    Customers Shrug Off S3 Service Failure - WIRED
    Feb 15, 2008 · At about 7:30 EST this morning, S3, Amazon.com's online storage service, went down. The 2-hour service failure affected customers worldwide, ...
  130. [130]
    Amazon explains its S3 outage - ZDNET
    Feb 16, 2008 · Here's Amazon's explanation of the S3 outage, which wreaked havoc on startups and other enterprises relying on Amazon's cloud.
  131. [131]
    Web startups crumble under Amazon S3 outage - The Register
    Feb 15, 2008 · Amazon said later that one of its three data centers for S3 was unreachable, beginning at 4:31 AM PST. It was back to "near normal" performance ...<|separator|>
  132. [132]
    Sony Data Breach: What Happened and How to Prevent It - StrongDM
    Sep 26, 2024 · In April 2011, hackers infiltrated Sony's PSN, affecting 77 million accounts using phishing and SQL injection, exposing personal data.
  133. [133]
    PlayStation Network's 24 days of downtime | 10 Years Ago This Month
    Apr 14, 2021 · PlayStation Network's 24 days of downtime | 10 Years Ago This Month. Sony's 2011 hack was covered as one of the biggest security breaches of all ...
  134. [134]
    BlackBerry outage for three days caused by faulty router says former ...
    Oct 14, 2011 · Insiders blame RIM's system, its poorly handled expansion and the demands of video content for failure that hit 70 million users.
  135. [135]
    THE RIM DISASTER TIMELINE: Blackberry's Collapse, As Told by ...
    Jul 28, 2012 · On October 12, 2011, the BlackBerry network went down due to a switch outage that shutdown BBM and e-mail for a day in the U.S. It was the ...
  136. [136]
    BlackBerry outage, what went wrong and what lessons RIM should ...
    RIM said the service disruption was due to a failure of a core hardware switch related to its BlackBerry Internet Servers (BIS).
  137. [137]
    Summary of the Amazon S3 Service Disruption in the Northern ...
    Feb 28, 2017 · The Amazon Simple Storage Service (S3) team was debugging an issue causing the S3 billing system to progress more slowly than expected.
  138. [138]
    Facebook Had The Largest Detected Outage In History Yesterday
    Mar 14, 2019 · The Facebook outage the largest to date, it far exceeds that of the second largest global outage experienced by YouTube in October 2018 with 200% more problem ...
  139. [139]
    Facebook returns after its worst outage ever | The Verge
    Mar 14, 2019 · The November 20th, 2018 outage affecting Facebook and Instagram was caused by a “bug in our server,” the company said at the time. With Facebook ...
  140. [140]
    Summary of June 8 outage | Fastly
    Jun 8, 2021 · We experienced a global outage due to an undiscovered software bug that surfaced on June 8 when it was triggered by a valid customer configuration change.
  141. [141]
    Inside the Fastly Outage: Analysis and Lessons Learned
    Jun 10, 2021 · Learn more about how the June 8, 2021 Fastly outage unfolded and how four different websites experienced the outage very differently.
  142. [142]
    More details about the October 4 outage - Engineering at Meta
    Oct 5, 2021 · Now that our platforms are up and running after yesterday's outage, we are sharing more detail on what happened and what we've learned.
  143. [143]
    Maintenance error caused Facebook's 6-hour outage, company says
    Oct 6, 2021 · An error during routine maintenance on Facebook's network of data centers caused Monday's collapse of its global system for more than six ...
  144. [144]
    Widespread IT Outage Due to CrowdStrike Update - CISA
    Aug 6, 2024 · Initial Alert (11:30 a.m., EDT, July 19, 2024):​​ CrowdStrike has confirmed the outage: Impacts Windows 10 and later systems.
  145. [145]
    Channel File 291 Incident RCA is Available - CrowdStrike
    On July 19, 2024, as part of regular operations, CrowdStrike released a content configuration update (via channel files) for the Windows sensor that resulted ...
  146. [146]
    CrowdStrike outage explained: What caused it and what's next
    Oct 29, 2024 · As of July 29, 2024, CrowdStrike reported that approximately 99% of affected Windows sensors were back online.
  147. [147]
  148. [148]
    How To Reduce Downtime: 7 Tips To Ensure Business Continuity
    Feb 26, 2024 · 1. Perform a Risk Assessment · 2. Track your Data · 3. Create a Proactive Maintenance Plan · 4. Train your Staff Regularly · 5. Establish Clear ...What is Downtime? · How to Reduce Business... · Create a Proactive...
  149. [149]
    Maximizing Uptime: Proactive Measures In Data Center Monitoring ...
    Jul 18, 2024 · Proactive capacity planning involves monitoring current resource usage and forecasting future demands to ensure that the data center can handle ...
  150. [150]
    The complete guide to scheduled maintenance for maximum uptime
    Scheduled maintenance clearly defines what needs to be serviced, why it is necessary, how it will be done, who will perform it, and exactly when it will occur.
  151. [151]
    What Is High Availability? - Cisco
    Redundancy means the IT components in a high-availability cluster, like servers or databases, can perform the same tasks.
  152. [152]
    Architecture Strategies for Designing for Redundancy - Microsoft Learn
    Sep 9, 2025 · This guide describes the recommendations for adding redundancy throughout critical flows at different workload layers, which optimizes resiliency.
  153. [153]
    [PDF] Data Center Downtime at the Core and the Edge - Vertiv
    Other steps participants listed could have an impact on reducing long-duration total facility outages, including redundant infrastructure equipment, improved ...Missing: effectiveness | Show results with:effectiveness
  154. [154]
    High Availability: Strategies for Uninterrupted Service
    Mar 22, 2025 · Redundancy plays a pivotal role in maintaining high availability by enabling failover to auxiliary components, thereby reducing downtime caused ...
  155. [155]
    Uptime and downtime analysis for hierarchical redundant systems in ...
    Aug 6, 2025 · For these downtime distributions, we study whether it is more cost effective to reduce failure rates or to speed up the response to failures ...
  156. [156]
    Incident Response: Best Practices for Quick Resolution | Atlassian
    One key activity is to create an incident response plan outlining the steps to take when an incident occurs. Many companies use incident response plan templates ...
  157. [157]
    What Is an Incident Response Plan for IT? - Cisco
    An incident response plan is a set of instructions to help IT staff detect, respond to, and recover from network security incidents.
  158. [158]
    [PDF] Computer Security Incident Handling Guide
    Apr 3, 2025 · This publication assists organizations in establishing computer security incident response capabilities and handling incidents efficiently and ...Missing: downtime | Show results with:downtime<|control11|><|separator|>
  159. [159]
    Incident Response Lifecycle: Stages and Best Practices | Atlassian
    The NIST incident response lifecycle breaks incident response down into four main phases: Preparation; Detection and Analysis; Containment, Eradication, and ...Get To Know The Incident... · Atlassian's Incident... · The Nist Incident Response...
  160. [160]
    [PDF] SANS 504-B Incident Response Cycle: Cheat-Sheet - Preparation
    SANS 504-B Incident Response Cycle: Cheat-Sheet v1.0, 11.5.2016-kf/USCW. Preparation - Identification - Containment - Eradication - Recovery - Lessons ...
  161. [161]
    7 Incident Response Metrics and How to Use Them
    Jan 24, 2025 · A robust incident response plan provides quantitative data. Check out these seven incident response metrics and how to use them.
  162. [162]
    SANS Incident Response: 6-Step Process & Critical Best Practices
    The SANS incident response process includes the following steps: preparation, identification, containment, eradication, recovery, and lessons learned.What Is SANS Incident... · Why Is SANS Providing... · Steps of the SANS Incident...
  163. [163]
    Incident Response Plan: Reduce Downtime & Build Trust | Siit
    Jul 19, 2025 · A structured response plan reduces risk through clear severity levels, defined roles, automated triage, and systematic post-incident analysis.
  164. [164]
    A Maintenance Revolution: Reducing Downtime With AI Tools
    Sep 17, 2025 · These disruptions impacted production timelines and increased operational costs, affecting overall productivity and profitability. Approach ...Missing: statistics | Show results with:statistics
  165. [165]
    AI and ML help predict and resolve IT outages before they occur
    The resulting model uses data, AI and ML to analyse various service management metrics, identify patterns and produce a risk score determining the likelihood ...
  166. [166]
    How AIOPs Can Predict and Prevent Network Outages - Infraon
    Dec 4, 2023 · Proactive Outage Prediction: AIOPs utilize machine learning to analyze data, identifying potential outages early through predictive analytics.
  167. [167]
    Outage Prediction and Grid Vulnerability Identification Using ...
    This project will use big data and machine learning to develop data-driven prediction model for weather-induced customer power outages.
  168. [168]
    Using AI in Predictive Maintenance: What You Need to Know - Oracle
    Dec 23, 2024 · Limits disruptions​​ AI reduces machine outages by predicting failures faster and more accurately than older methods. This helps manufacturers ...
  169. [169]
    Fault-Tolerant Computing: Fundamental Concepts
    They are: error detection, masking, and correction; error detection and correction codes; self-checking logic; module replication for error detection and ...
  170. [170]
    Fault Tolerance for Corporate Data Center Environments
    Predictive fault tolerant computing platforms enable organizations to run mission-critical applications in data center environments without downtime or data ...
  171. [171]
    Fault Tolerance vs High Availability - Scale Computing
    Feb 7, 2024 · Fault tolerance refers to an IT infrastructure's ability to continue functioning even when part of the system fails or experiences unexpected disruptions.
  172. [172]
    Edge Computing and Predictive Maintenance: Preventing Downtime
    Apr 2, 2025 · Edge computing transforms predictive maintenance from a complex task into a practical solution, enabling manufacturers to anticipate equipment issues, reduce ...
  173. [173]
    Edge Computing Enables Real-Time Maintenance Decision Making
    Jul 12, 2025 · Discover how edge computing transforms manufacturing maintenance by enabling instant decision-making, reducing downtime, and optimizing ...Missing: avoidance | Show results with:avoidance
  174. [174]
    Are Edge Computing, and Fiber Networks Eliminating Downtime?
    Apr 2, 2025 · AI, edge computing, and fiber networks are leading the charge, ensuring that real-time applications perform seamlessly with minimal downtime.Missing: avoidance | Show results with:avoidance
  175. [175]
    How to Protect Your Edge Computing Deployments to Minimize IT ...
    Oct 5, 2021 · Remote edge computing management solutions offering total visibility into IT infrastructure are essential for minimizing IT outages to ...
  176. [176]
    [PDF] Cloud Computing Synopsis and Recommendations
    It is sometimes asserted that when compared to traditional on premises computing, cloud computing requires consumers to give up (to providers) two important ...
  177. [177]
    Yes, Cloud Is Still Safe Despite The AWS Outage - UPDATE - Forrester
    Mar 2, 2017 · 99.99% availability target means at least an hour a year of failure is expected. Don't count on any layer of your technology stack to be there ...
  178. [178]
    How Downtime With Information Systems Can Cost Business ...
    Downtime is typically measured in minutes, hours, or days and categorized as planned or unplanned. Planned downtime includes scheduled maintenance, updates, or ...
  179. [179]
    Regulation Systems Compliance & Integrity (SCI) - SEC.gov
    Nov 19, 2014 · Regulation SCI is an important first step at tackling the inherent vulnerabilities in a marketplace dominated by computers. All plugged-in ...
  180. [180]
    Regulation SCI—Systems Compliance and Integrity - eCFR
    (2) Provide functionality to the securities markets for which the availability of alternatives is significantly limited or nonexistent and without which there ...
  181. [181]
    Responses to Frequently Asked Questions Concerning Regulation ...
    Sep 2, 2015 · The Commission adopted Regulation SCI and Form SCI (“Form”) in November 2014 to strengthen the technology infrastructure of the US securities markets.
  182. [182]
    47 CFR Part 4 -- Disruptions to Communications - eCFR
    In this part, the Federal Communications Commission is setting forth requirements pertinent to the reporting of disruptions to communications.
  183. [183]
    Network Outage Reporting System (NORS)
    The Part 4 rules also require communications providers to report certain communications disruptions affecting specific aspects of 9-1-1 communications, special ...
  184. [184]
    Summary of the HIPAA Security Rule - HHS.gov
    Dec 30, 2024 · The Security Rule establishes a national set of security standards to protect certain health information that is maintained or transmitted in electronic form.
  185. [185]
    Cybersecurity under NIS-2: What is changing for critical infrastructures
    What is NIS 2 Directive? The NIS 2 Directive (EU) 2022/2555 sets out cybersecurity requirements for operators of critical and important facilities in the EU.Missing: effects | Show results with:effects
  186. [186]
  187. [187]
    Why Facebook and Instagram went down for hours on Monday - NPR
    Oct 5, 2021 · When Facebook suffered an outage of about six hours on Monday, businesses suffered along with it. The platform and its Instagram and ...
  188. [188]
    Facebook outage highlights global over-reliance on its services
    Facebook's outage highlighted the dependence much of the world has developed on its social media products, and put the spotlight on its global power.
  189. [189]
    2025 Data Center Outage Report: Are You Ready for the Changing ...
    Aug 19, 2025 · In the Uptime Institute 2024 Global Data Center Survey, only 53% of operators reported experiencing an outage in the past three years. That's ...
  190. [190]
    Y2K Explained: The Real Impact and Myths of the Year 2000 ...
    Aug 29, 2025 · The Y2K bug was a feared computer glitch that could have caused major disruptions as the year changed from 1999 to 2000. Extensive worldwide ...
  191. [191]
    20 Years Later, the Y2K Bug Seems Like a Joke—Because Those ...
    Dec 30, 2019 · The term Y2K had become shorthand for a problem stemming from the clash of the upcoming Year 2000 and the two-digit year format utilized by early coders.
  192. [192]
    Annual Outage Analysis 2025 - Uptime Institute
    This report analyzes recent data on the causes, frequency and consequences of IT and data center outages.
  193. [193]
    Publicly reported outages see increase in deliberate attacks
    Jun 11, 2025 · The number of major outages caused by cyberattacks (from data analyzed by Uptime Intelligence) has almost doubled in the past three years (see ...
  194. [194]
    Data Center Outage Frequency Decreasing | APMdigest
    May 8, 2025 · Power remains the leading cause of impactful outages. Outages from IT and networking issues increased in 2024, totaling 23% of impactful outages ...Missing: empirical | Show results with:empirical
  195. [195]
    IT Outage Impact Study | LogicMonitor
    Downtime is avoidable. 51% of outages are avoidable as are 53% of brownouts, according to global IT decision makers. Downtime is expensive. Companies with ...
  196. [196]
    New Relic Study Reveals IT Outages Cost Businesses Up to $1.9 M ...
    Oct 22, 2024 · Those with business observability experienced 40% less annual downtime, spent 24% less on hourly annual outage costs, and spent 25% less time ...
  197. [197]
    Network outages are on the rise: 84% of businesses report ...
    Sep 4, 2025 · Nearly nine in ten organizations have experienced an increase in network outages over the past two years, with more than a quarter reporting ...