The Fick principle is a foundational method in cardiovascular physiology for measuring cardiac output, which represents the volume of blood pumped by the heart per minute, by leveraging the relationship between systemic oxygen consumption and the difference in oxygen content between arterial and mixed venous blood. Developed in 1870 by German physiologist Adolf Eugen Fick, the principle posits that the total oxygen uptake by peripheral tissues equals the product of cardiac output and the arteriovenous oxygen concentration difference, expressed mathematically as \text{Cardiac Output} = \frac{\text{Oxygen Consumption}}{\text{Arterial O}_2 \text{ Content} - \text{Mixed Venous O}_2 \text{ Content}}. This non-invasive or minimally invasive technique, often involving pulmonary artery catheterization for venous sampling, remains a gold standard for assessing cardiac function in clinical settings such as intensive care and cardiology, despite limitations like the need for steady-state conditions and accurate oxygen measurement. Beyond cardiac output, the principle extends to quantifying blood flow in specific organs or detecting intracardiac shunts by applying the same uptake/release logic to other substances like carbon dioxide or indicators. Its enduring utility underscores Fick's contributions to integrating mathematics and physiology, influencing modern hemodynamic monitoring and research in circulatory dynamics.

Introduction and History

Definition and Overview

The Fick principle is a fundamental concept in derived from the , stating that the amount of a substance taken up or released by an per unit time equals the blood flow through the multiplied by the arteriovenous concentration difference of that substance across the . This relationship allows for the indirect of physiological parameters by tracking the uptake or elimination of a suitable indicator substance, assuming steady-state conditions and complete mixing of blood. In practice, the principle plays a key role in quantifying blood flow rates and clearance mechanisms in various organs, enabling assessments of overall circulatory efficiency and tissue perfusion without direct invasive measurements. For instance, it facilitates the calculation of systemic flows by relating substance consumption to concentration gradients, providing insights into metabolic demands and organ function. It is important to distinguish the Fick principle from , which describe the rate of across a concentration in a medium, proportional to the , surface area, and inversely to thickness, focusing on at the cellular level rather than bulk convective flow in . The principle instead emphasizes advective via flow, making it applicable to macroscopic organ-level processes. Primary applications include measuring through oxygen consumption differences and estimating (GFR) via clearance of filtered substances like , where renal plasma flow and filtration fractions are derived from urinary excretion rates relative to plasma concentrations.

Historical Background

The Fick principle was proposed by Adolf Eugen Fick, a German-born (1829–1901), in 1870 during his tenure as a professor of physiology at the . In a presentation to the Physical-Medical Society of titled "Über die Messung des Blutquantums in den Herzventrikeln," Fick outlined a theoretical method to quantify blood flow through an organ by tracking the uptake or release of a substance, specifically using oxygen as the indicator due to its role in metabolic processes. This approach stemmed from Fick's broader research interests in and energy expenditure, where he sought to link oxygen consumption directly to circulatory dynamics. Although groundbreaking, Fick's idea remained largely conceptual at the time, as he did not conduct empirical tests himself but emphasized the need for precise measurements of oxygen levels in arterial and . Early attempts to validate the principle experimentally faced significant hurdles, primarily the lack of reliable techniques for accurately determining oxygen concentrations in samples. The first practical demonstration occurred in 1886, when French physiologists Nestor Gréhant and Charles Eugène Quinquaud applied it in dogs, measuring oxygen consumption and arteriovenous differences to estimate , yielding values consistent with direct anatomical methods. Despite this progress, applications in larger animals and humans were limited by methodological constraints, such as imprecise oximetry and the challenges of maintaining steady-state conditions during measurements. It was not until the development of the Van Slyke manometric apparatus in the for gas analysis that more accurate validations became feasible, though widespread adoption still lagged. Practical implementation in clinical settings advanced dramatically in the 1940s, integrated into cardiac catheterization techniques pioneered by Werner Forssmann, André Cournand, and Dickinson W. Richards, who shared the 1956 Nobel Prize in Physiology or Medicine for their work. This era marked the principle's transition from theory to routine use in assessing cardiac output in patients with heart disease, enabled by catheterization's ability to sample mixed venous blood directly from the pulmonary artery. By the mid-20th century, the Fick principle's utility extended beyond cardiology, gaining recognition in renal physiology for estimating organ blood flow through indicator substances and in exercise physiology for analyzing whole-body oxygen utilization during physical activity. These developments solidified its foundational role in quantitative physiology, influencing subsequent innovations in metabolic and circulatory research.

Principles and Formulation

Underlying Principles

The Fick principle rests on the fundamental law of , which states that in a under steady-state conditions, the mass of a substance entering the system must equal the mass exiting it plus any net consumption or production within the system. This conservation ensures that no substance is created or destroyed arbitrarily, providing a balanced accounting of material flows. In physiological applications, organs or the entire body are conceptualized as "black boxes," where internal processes are not directly observed, but the principle allows quantification of substance balance through measurable inflows and outflows at the system's boundaries, such as arterial and . This approach simplifies complex biological systems by focusing on net exchanges rather than intricate metabolic pathways. A key requirement is the steady-state assumption, wherein biological rates—such as blood flow and substance concentrations—remain constant over the measurement interval, enabling the conservation balance to hold without transient fluctuations disrupting the . In living organisms, this typically applies during periods of relative metabolic , like , where dynamic changes in demand are minimal. The principle requires an appropriate indicator substance that is consumed or produced by the target organ, resulting in a detectable arteriovenous concentration difference to ensure accurate representation of the ; for instance, oxygen is consumed by tissues (often with partial extraction), and it must be precisely measurable in samples. Such indicators should be chosen to minimize issues like recirculation or external losses, maintaining the integrity of the conservation calculation. This framework was originally proposed by Adolf Fick in 1870 as a method to quantify physiological flows based on mass balance.

Variables and Equation

The Fick principle is mathematically formulated to determine the flow rate of blood through an organ or the body by relating the rate of uptake or release of a substance to the concentration difference across the vascular bed. The key variables are as follows: Q represents the flow rate, such as cardiac output, typically measured in liters per minute (L/min); \dot{X} denotes the uptake rate of the substance by the tissues, for example, oxygen consumption in milliliters per minute (ml/min); C_a is the arterial concentration of the substance, expressed in ml/L; and C_v is the venous concentration, also in ml/L. The standard equation is Q = \frac{\dot{X}}{C_a - C_v} This ensures dimensional consistency; for oxygen, \dot{X} is in ml O_2/min and (C_a - C_v) in ml O_2/L, yielding in L/min. The principle originates from Fick's 1870 work, where he proposed this relationship for measuring using oxygen as the marker substance. The equation generalizes to any substance that is neither produced nor consumed within the blood and for which or rates can be quantified, allowing application beyond oxygen to assess flows in various physiological contexts. For example, in , the clearance of —a freely filtered substance not reabsorbed or secreted—follows an analogous form, where equals the rate ( concentration times ) divided by plasma concentration, effectively assuming zero venous concentration. Notation variations appear in the , with sometimes denoted as F rather than , and as \dot{V} for specific substances like oxygen (\dot{V}O_2).

Derivation

The Fick principle derives from the fundamental applied to a substance (such as oxygen) across an or the entire , treated as a "" system in . Consider blood flow Q (volume per unit time) entering the system via an with substance concentration C_a (mass per unit volume), and exiting via a with concentration C_v. The mass inflow rate is thus Q \cdot C_a, representing the amount of substance delivered to the system per unit time. The mass outflow rate is Q \cdot C_v, the amount leaving the system. The net uptake rate of the substance by the system—equal to the difference between inflow and outflow—is therefore Q \cdot (C_a - C_v). This net uptake quantifies the or extraction of the substance within the system. In , where concentrations and flow are constant over time, this net uptake equals the independently measured rate \dot{X} (mass per unit time) of the substance by the tissues or organ. Thus, Q \cdot (C_a - C_v) = \dot{X}. Rearranging for flow yields the Fick equation: Q = \frac{\dot{X}}{C_a - C_v}. This formulation directly links measurable quantities to the flow rate. To illustrate, envision a simple black-box model:
Artery (inflow: Q at C_a) 
[Organ/Tissue (net uptake: \dot{X})] 
[Vein](/page/Vein) (outflow: Q at C_v)
This depicts unidirectional flow through the system, with the substance partially extracted en route. The principle accommodates extraction ratios E = (C_a - C_v)/C_a < 1, as the arteriovenous difference C_a - C_v inherently captures the fractional extraction without assuming complete removal; the formula remains valid for partial uptake. However, for substances with low extraction (small C_a - C_v), precise measurement of concentrations is essential, and adjustments may be required in practice to account for incomplete mixing or recirculation effects that could bias C_v.

Applications in Physiology

Cardiac Output Measurement

The Fick principle is applied to measure cardiac output by quantifying the rate at which oxygen is consumed by the body and relating it to the difference in oxygen content between arterial and mixed venous blood. The procedure involves determining whole-body oxygen consumption (ẎO₂) through spirometry or a closed respiratory system that records inspired and expired oxygen volumes, typically yielding values around 250 mL/min at rest for an average adult. Arterial oxygen content (CaO₂) is calculated from a peripheral arterial blood gas sample, incorporating hemoglobin concentration, oxygen saturation, and dissolved oxygen, often approximately 200 mL/L under normal conditions. Mixed venous oxygen content (CvO₂) is obtained via a pulmonary artery catheter sampling blood from the right ventricle or pulmonary artery, typically around 150 mL/L, reflecting oxygen extraction by tissues. This method gained prominence in the 1940s through the work of and at Bellevue Hospital, who integrated the with cardiac catheterization to directly assess pulmonary blood flow and cardiac function in patients with heart disease. Their pioneering studies, beginning in 1941, enabled precise measurements during invasive procedures, revolutionizing the diagnosis of congenital and acquired cardiac conditions. For their contributions to heart catheterization and circulatory pathophysiology, Cournand and Richards shared the in 1956 with . An illustrative calculation demonstrates the principle's application: with ẎO₂ at 250 mL/min, CaO₂ at 200 mL/L, and CvO₂ at 150 mL/L, cardiac output (CO) is computed as CO = ẎO₂ / (CaO₂ - CvO₂) = 250 / (200 - 150) = 5 L/min. This example highlights how the arteriovenous oxygen difference drives the output estimate, with units adjusted for consistency (e.g., converting mL/L to match mL/min). The Fick method offers key advantages, including the non-invasive measurement of oxygen uptake via spirometry, which avoids additional instrumentation beyond blood sampling. It serves as the gold standard for validating other techniques, such as thermodilution, providing superior accuracy in scenarios like low cardiac output states or tricuspid regurgitation where thermodilution may falter due to indicator dilution errors.

Renal Physiology

In renal physiology, the Fick principle is applied to measure the glomerular filtration rate (GFR) by assessing the clearance of inulin, a substance that is freely filtered at the glomerulus but neither reabsorbed nor secreted by the renal tubules. Inulin is infused to achieve a steady-state plasma concentration, and its urinary excretion rate (\dot{X}) equals the filtration rate due to complete extraction from the filtered plasma (with venous concentration C_v \approx 0). The GFR is then calculated as \text{GFR} = \frac{\dot{X}}{C_a}, where C_a is the arterial plasma inulin concentration; this yields a normal value of approximately 120–125 mL/min in healthy adults. To estimate renal plasma flow (RPF), the Fick principle employs para-aminohippuric acid (PAH), which is almost completely extracted by the kidneys through both glomerular filtration and tubular secretion, achieving near-total removal (extraction ratio ≈ 0.9) in a single pass. PAH is infused to steady state, and the principle equates the amount of PAH delivered to the kidneys with its urinary excretion plus the small amount remaining in renal venous blood. Thus, RPF is given by \text{RPF} = \frac{\dot{X}_{\text{PAH}}}{C_{a,\text{PAH}} - C_{v,\text{PAH}}}, where \dot{X}_{\text{PAH}} is the urinary excretion rate of PAH, C_{a,\text{PAH}} is the arterial plasma PAH concentration, and C_{v,\text{PAH}} is the venous concentration; typical RPF values range from 600–700 mL/min. The filtration fraction (FF), representing the proportion of plasma filtered at the glomerulus, is derived directly from these measurements as \text{FF} = \frac{\text{GFR}}{\text{RPF}}, normally about 0.20 (20%) in healthy individuals. These Fick-based assessments provide gold-standard evaluation of renal function, particularly in clinical contexts like , where reduced (e.g., <60 mL/min/1.73 m²) stages disease progression and guides interventions such as dosing adjustments or dialysis initiation. Although inulin and PAH methods are invasive and largely research-oriented today, they remain benchmarks for validating estimated GFR formulas in CKD management.

Other Physiological Applications

In exercise physiology, the Fick principle is applied to estimate muscle blood flow and oxygen utilization by quantifying the arteriovenous oxygen difference across a specific limb or muscle group during physical activity. For instance, during dynamic exercise, blood flow to the exercising muscle can be calculated as the ratio of muscle oxygen consumption to the arteriovenous oxygen content difference, providing insights into local perfusion and metabolic demands without invasive systemic measurements. This approach has been instrumental in studying oxygen transport kinetics in skeletal muscle, revealing how blood flow adjusts to match increased oxidative needs, such as during moderate-intensity cycling where muscle capillary blood flow rises proportionally to oxygen uptake. In pulmonary physiology, the Fick principle facilitates the assessment of shunt fractions and ventilation-perfusion (V/Q) matching by analyzing gas exchange efficiency across the lungs. It quantifies intrapulmonary shunting as the fraction of cardiac output that bypasses effective gas exchange, derived from the difference between end-pulmonary capillary and mixed venous oxygen contents relative to arterial-venous differences. This method helps evaluate V/Q mismatches in conditions like acute respiratory distress syndrome, where elevated shunt fractions (e.g., >20%) correlate with impaired oxygenation and guide therapeutic interventions such as . Beyond these, the Fick principle extends to organ-specific flows in and . In , hepatic blood flow is estimated via (ICG) clearance, where the indicator's uptake by the liver equals its arterial delivery minus venous output, assuming complete extraction; this yields effective hepatic flow values around 1,000 /min in healthy adults, aiding in the diagnosis of liver dysfunction. In , the Kety-Schmidt method measures cerebral blood by tracking the inert gas's arteriovenous concentration gradient until equilibrium, applying the Fick equation to compute global cerebral at approximately 50 /100 g/min under resting conditions. Modern extensions integrate the Fick principle with non-invasive imaging techniques like () for regional blood flow quantification. In PET perfusion studies, radiolabeled tracers such as 15O-water follow Fick-based kinetic models to map tissue-specific flows, enabling the assessment of heterogeneous in organs like the or myocardium with down to millimeters. This approach has advanced clinical applications, such as identifying ischemic regions in patients where regional cerebral blood flow drops below 20 mL/100 g/min, surpassing the limitations of traditional invasive methods.

Assumptions and Limitations

Key Assumptions

The Fick principle relies on several fundamental assumptions to ensure accurate estimation of blood flow or organ perfusion using a marker substance, such as oxygen. These assumptions establish the biological and physiological prerequisites for the principle's application in measurements like cardiac output. A primary assumption is that the system operates under steady-state conditions, where substance concentrations in arterial and venous blood, as well as blood flow rates and metabolic rates, remain constant over the measurement period. This requires no acute changes in metabolism, such as those occurring during exercise or hemodynamic instability, to prevent discrepancies between measured uptake and actual consumption. For instance, oxygen consumption must be stable, with pulmonary uptake equaling tissue utilization without transient fluctuations. Complete mixing of blood is another essential assumption, meaning that arterial and venous samples must represent fully homogenized concentrations across the respective compartments. In cardiac output determination, this entails sampling from a site like the or systemic artery to capture true mixed arterial content, and mixed from the to reflect average systemic venous return. Incomplete mixing, such as from sampling peripheral veins or inadequate homogenization in the right ventricle, can lead to erroneous arteriovenous differences. The chosen indicator substance must be suitable for the , exhibiting known and consistent or release by the target organ or tissue without endogenous production or extraneous . Oxygen, commonly used in physiological applications, satisfies this by being steadily consumed by tissues for and not produced by them, allowing reliable quantification of the arteriovenous concentration difference. Unsuitable indicators, such as those subject to variable storage or synthesis, would invalidate the calculation. Finally, the principle assumes no recirculation of the substance back into the arterial system prematurely or loss outside the measured , ensuring all uptake or release is attributable solely to the of interest. For oxygen in systemic applications, this implies no significant intracardiac or intrapulmonary shunts that bypass tissue extraction, and negligible consumption or addition by non-target structures like the lungs under normal conditions. Violation through shunts or extracorporeal losses would distort the concentration gradient.

Limitations and Considerations

The Fick principle's application in measuring cardiac output is susceptible to measurement errors, particularly in the Fick-derived oxygen consumption, which can underestimate direct measurements with a precision error of approximately 20-22% of mean values. Sampling issues, such as incomplete mixing of venous blood in the pulmonary artery, can further lead to systematic errors. Ventilation-perfusion mismatches in the lungs also compromise accuracy by violating the assumption of uniform gas exchange, potentially resulting in over- or underestimation of cardiac output. The method's invasive nature, requiring pulmonary artery catheterization for mixed venous blood sampling, limits its routine clinical use and introduces procedural risks, including infection, bleeding, and arrhythmia, particularly in critically ill patients. These ethical and practical considerations often restrict the direct Fick approach to specialized settings like cardiac catheterization laboratories, where it is infrequently employed due to the need for simultaneous arterial and venous sampling under controlled conditions. In non-steady-state conditions, such as the onset of exercise or hemodynamic in , the Fick principle becomes invalid because oxygen consumption and blood flow do not equilibrate, leading to unreliable estimates of . Modern advancements address these limitations through non-invasive alternatives and validations; for instance, inert gas rebreathing methods have been compared against and phase-contrast MRI, showing moderate agreement in stable patients with errors around 30% (Bland-Altman limits ±0.6 L/min/m²). Approximations based on rebreathing, rather than oxygen, enable less invasive assessments via , with ongoing validation studies demonstrating clinical utility in intensive care settings as of 2025. Emerging research into wearable technologies, such as photoplethysmography-based monitors, aims to provide real-time, non-invasive estimates, though these require further prospective trials for broad adoption.

References

  1. [1]
    Calculating FICK Cardiac Output and Input - StatPearls - NCBI - NIH
    May 29, 2024 · The Fick principle is crucial in determining cardiac output by relating tissue oxygen consumption and oxygen concentrations in arterial and venous blood.
  2. [2]
    Adolf Eugen Fick (1829-1901) - The Man Behind the Cardiac Output ...
    Oct 15, 2020 · In 1870, he devised Fick's principle, which allows the measurement of cardiac output and calculations of intracardiac shunts from the ...
  3. [3]
    The Fick principle – cardiac output measurement
    Jul 5, 2014 · The Fick principle (Adolf Eugen Fick, 1870), otherwise known as the 'Inverse Fick equation', allows the measurement of cardiac output.
  4. [4]
    Cardiac output - Fick method - Medscape Reference
    The Fick principle, as applied to cardiac output, relies on the recognition that the total uptake of oxygen by the peripheral tissues is equal to the product ...Missing: explanation | Show results with:explanation
  5. [5]
    Fick Principle - an overview | ScienceDirect Topics
    The Fick principle states that the total uptake or release of a substance by an organ is the product of the organ's blood flow and the arteriovenous ...
  6. [6]
    Adolf Fick—Forgotten genius of cardiology - ScienceDirect.com
    Nov 8, 1972 · His principle for determining the cardiac output is used many times each day in cardiologic centers. His studies of myocardial mechanics led ...
  7. [7]
    Fick principle – Knowledge and References - Taylor & Francis
    The Fick principle is a law of conservation of mass that states the amount of substance taken up by an organ per unit time is equal to the arterial ...
  8. [8]
    Physiology, Cardiac Output - StatPearls - NCBI Bookshelf - NIH
    Fick's principle illustrates this notion and can be used to calculate cardiac output based on oxygen exchange through a capillary bed.
  9. [9]
  10. [10]
    Adolf Eugen Fick (1829-1901) – The Man Behind the Cardiac Output ...
    Oct 15, 2020 · In 1855, he proposed Fick's laws on gas diffusion. In 1870, he devised Fick's principle, which allows the measurement of cardiac output and ...
  11. [11]
    Kidney Blood Flow - an overview | ScienceDirect Topics
    All the inulin filtered from the blood in the kidney glomeruli passes into the urine. Thus the Fick principle may be applied: if the concentration in the renal ...
  12. [12]
    Fick, A. (1870) Uber die messung des Blutquantums in ... - Scirp.org.
    Fick, A. (1870) Uber die messung des Blutquantums in den Hertzvent rikeln. Sitzber Physik Med Ges Wurzburg July 9th, 36.Missing: Blutquantum | Show results with:Blutquantum
  13. [13]
    Adolph Fick: Mathematician, Physicist, Physiologist
    ... Fick's principle is expressed by the following equation: Cardiac output = oxygen consumption / arteriovenous oxygen difference. As usual, Fick did not bother ...<|control11|><|separator|>
  14. [14]
    Fick's Principle of cardiac output measurement - Deranged Physiology
    Dec 18, 2023 · Fick's principle states that total uptake of a substance equals blood flow multiplied by the arterial-venous concentration difference of that ...
  15. [15]
    History of Right Heart Catheterization: 100 Years of Experimentation ...
    In Fick's original description, oxygen consumption was the indicator measured in the body, however this method was rarely used due to the difficulty of ...
  16. [16]
    The beginnings of cardiac catheterization and the resulting impact ...
    The early history of cardiac catheterization has many interesting features. First ... Fick principle to calculate total pulmonary blood flow. Cournand's initial ...
  17. [17]
    Fatty acids as substrates for heart and skeletal muscle.
    Fick enunciated, in. 1870, one of the statements we call the Fick principle. ... Hagenfeldt L, Wahren J: Human forearm muscle metabolism during exercise ...
  18. [18]
    Erythrocytes: surveyors as well as purveyors of oxygen? | American ...
    One way to quantify oxygen transport is to employ Fick's principle ... This “black box” approach works particularly well ... Looking into the “black box ...
  19. [19]
    The Fick Principle and the Steady State - ATS Journals
    Neither Fick nor Cournand and Richards took cognizance of the need for a steady state of the respiration and circulation for valid measurement of oxygen ...
  20. [20]
    Renal Clearance
    Renal clearance is defined as the volume of plasma that is cleared of a substance by the kidneys per unit time. The formula for clearance is: Note that the ...
  21. [21]
    Methods in pharmacology: measurement of cardiac output - PMC
    Fick's cardiac output measurement. Direct Fick for oxygen. In 1870, Adolf Fick described a method to estimate cardiac output based on a mass balance for oxygen.Missing: derivation | Show results with:derivation
  22. [22]
    Measurement of Cardiac Output - CV Physiology
    If CaO2 and CvO2 are 0.2 mL and 0.15 mL O2/ml blood, respectively, and VO2 is 250 mL O2/minute, then CO = 5000 mL/min, or 5 L/min. Ventricular stroke volume ...
  23. [23]
    The Nobel Prize in Physiology or Medicine 1956 - NobelPrize.org
    ... Cournand, Werner Forssmann and Dickinson W. Richards "for their discoveries concerning heart catheterization and pathological changes in the circulatory system".
  24. [24]
    Cardiac Output Estimation in the Intensive Care Unit | JACC: Advances
    The clinical gold standard for assessing CO is the “direct Fick” technique, wherein CO is computed from the Fick principle using resting measurements of a ...
  25. [25]
    Physiology, Glomerular Filtration Rate - StatPearls - NCBI Bookshelf
    We standardize clearances by comparing them to inulin/creatinine which is assigned clearance of 1. Substances that are reabsorbed will have a clearance of less ...
  26. [26]
    Kidney Plasma Flow - an overview | ScienceDirect Topics
    Glomerular filtration rate (GFR) is measured by the clearance of inulin, a fructose polysaccharide that is readily filtered but not resorbed or secreted by the ...
  27. [27]
    Chronic Kidney Disease - StatPearls - NCBI Bookshelf
    Jul 31, 2024 · CKD is a state of progressive loss of kidney function, ultimately resulting in the need for renal replacement therapy, such as dialysis or transplantation.
  28. [28]
    Kinetics of muscle oxygen use, oxygen content, and blood flow ...
    From the Fick principle, muscle capillary blood flow is the ratio of muscle O2 consumption to arteriovenous O2 difference (AVD) (Eq. 1 in Table 1). The τ of ...
  29. [29]
    Exercise and Hemorrhage - Regulation of Tissue Oxygenation - NCBI
    Oxygen transport during muscle contraction has been analyzed according to Fick's principle with the results interpreted in terms of a microvascular perspective ...<|separator|>
  30. [30]
    A novel 'shunt fraction' method to derive native cardiac output during ...
    Nov 1, 2023 · The Fick principle is an established method to quantify intracardiac shunts. The Fick principle has also found utility in the practice of ...Missing: matching | Show results with:matching
  31. [31]
    [PDF] estimation of hepatic blood flow with indocyanine green
    ICG clearance was studied during hepatic vein catheterization and was followed by an estimation of hepatic blood flow by the Fick principle, using a con-.
  32. [32]
    Quantitative Perfusion Imaging with Total-Body PET
    Nov 1, 2023 · Modeling of 15O-water PET data is based on the 1-tissue-compartment model (17), related to the Fick principle describing the exchange of inert ...
  33. [33]
    Tracer Kinetic Modeling in PET - ScienceDirect.com
    Molecular imaging using PET provides a unique tool for noninvasively investigating the biochemistry of living organs. The wide range of radiolabeled ...
  34. [34]
    Blood Flow Measurement: Cardiac Output and Vascular Resistance
    Jun 26, 2016 · The techniques described for cardiac output measurement by application of Fick's principle assume that a steady state exists (i.e., that the ...
  35. [35]
    Oxygen consumption calculated from the Fick equation has limited ...
    If true VO2 changes, the magnitude and direction of change will be reflected by calculated VO2 but with approximately 20% error in the absolute value. Heart ...Missing: principle | Show results with:principle
  36. [36]
    Thermodilution and Fick cardiac outputs differ: Impact on pulmonary ...
    The direct Fick typically involves directly measuring the patient's oxygen consumption in the catheterization laboratory rather than using an assumed oxygen ...
  37. [37]
    Validation of Noninvasive Measurement of Cardiac Output Using ...
    Mar 10, 2017 · CO measurement using the Fick method—which is considered the gold-standard method—is limited primarily by the need for invasive catheterization, ...
  38. [38]
    Validation of the capnodynamic method to calculate mixed venous ...
    Mar 7, 2025 · This study primarily investigated the agreement between mixed venous oxygen saturation calculated using the capnodynamic method and blood gas analysis.Capnodynamic Method · Mixed Venous Oxygen... · Sources Of Error In The...Missing: modern | Show results with:modern
  39. [39]
    Assessing Cardiac Flow Measurements Using a Noninvasive ...
    Aug 22, 2025 · The aim of the study was to compare invasive hemodynamic measurements using a noninvasive wearable photoplethysmography-based (PPG) monitor and ...Missing: modern | Show results with:modern