Loading coil

A loading coil is an electrical connected in series with the conductors of a , such as a wire, at uniform intervals to artificially increase the line's per unit length and counteract the effects of distributed , thereby reducing signal and for efficient long-distance communication. This device operates on the principle of balancing the line's electrical parameters to approximate distortionless propagation, as described in the Heaviside condition—formulated by in 1887—which states that distortion-free transmission requires the ratio of series resistance to shunt conductance to equal the ratio of series to shunt (R/G = L/C). Heaviside proposed adding discrete inductors, or loading coils, along lines in 1893 to achieve this balance, addressing the typical imbalance in practical conductors where is too low relative to . The practical development of loading coils for occurred independently in the late 1890s, with George A. Campbell at conducting theoretical and experimental work starting around 1897, leading to successful field tests by September 1899 that demonstrated significantly improved signal quality over long distances. Michael I. Pupin, a professor, arrived at a similar solution and filed for a U.S. patent in December 1899, receiving patent number 652,230 on June 19, 1900, for the "Art of reducing of electrical waves and apparatus therefor," which detailed the use of coils spaced at intervals no greater than one-sixteenth of the shortest to minimize energy loss. Although Campbell's earlier efforts predated Pupin's filing, Pupin secured the patent rights, prompting to the technology for $435,000 to avoid litigation, after which the coils—often called Pupin coils—became standard in telephone networks. Loading coils revolutionized by enabling clear voice transmission over loops exceeding 18,000 feet, where unloaded lines would suffer excessive high-frequency due to ; typical designs, such as the 88 H88 coil spaced every 6,000 feet, equalize across the voice band (300–3,000 Hz) while limiting broadband data services like DSL on the same lines. Their implementation extended the range of early systems dramatically, supporting the growth of national networks, though they were later phased out in favor of optics and digital technologies.

Principles of Operation

Definition and Purpose

A loading coil is an inductor inserted at regular intervals along a transmission line to increase its overall inductance per unit length, thereby modifying the line's electrical characteristics. This lumped element compensates for the inherent imbalance between the line's distributed capacitance and inductance, which is typically too low in practical conductors. The primary purpose of a loading coil is to reduce signal attenuation and distortion, particularly phase distortion, in voice-frequency signals transmitted over long distances. By elevating the inductance, it makes the characteristic impedance of the line more resistive in nature and equalizes the velocity of propagation across different frequencies, promoting distortionless transmission. This approach stems from the theoretical Heaviside condition, which underscores the need for balanced inductance and capacitance to minimize waveform distortion. In basic construction, a loading coil consists of a coil of enameled wire wound around a ferromagnetic , such as iron or , to enhance its inductive properties while minimizing . It is placed in series with the line , typically one coil per conductor in a balanced pair, integrating seamlessly into the to add the required without significantly altering the line's . The term "loading coil" originated in 19th-century practices but applies broadly to circuits where boosting is essential. A key benefit of loading coils is their ability to enable reliable over extended distances in early systems, where intermediate was not yet feasible, thus extending the practical of communication lines.

Heaviside Condition

In his analysis, derived the to model signal propagation along transmission lines, incorporating distributed parameters for resistance R, L, conductance G, and C per unit length. These equations are given by \frac{\partial V}{\partial x} = -(R I + L \frac{\partial I}{\partial t}), \frac{\partial I}{\partial x} = -(G V + C \frac{\partial V}{\partial t}), where V(x,t) is the voltage and I(x,t) is the current at position x and time t. Heaviside showed that these describe wave-like propagation with attenuation, building on earlier work by applying Maxwell's electromagnetic theory to practical lines. Building on this framework in 1887, Heaviside identified the condition for distortionless , where signals maintain their without or frequency-dependent . For such a line, the propagation velocity is v = 1 / \sqrt{[LC](/page/LC)}, independent of frequency, and the parameters must satisfy R/L = G/C. This relation, equivalently expressed as L/C = R/G, ensures that resistive and conductive losses balance inductive and capacitive effects, resulting in uniform across frequencies and shift. To derive this, consider solutions to the telegrapher's equations assuming a traveling wave form V(x,t) = \Re \{ \hat{V} e^{j\omega t - \gamma x} \}, where \gamma = \alpha + j\beta is the complex propagation constant, with \alpha the attenuation constant and \beta the phase constant. Substituting yields \gamma = \sqrt{(R + j\omega L)(G + j\omega C)}. For distortionless propagation, \alpha must be frequency-independent and \beta = \omega / v linear in \omega. Setting R/L = G/C = k simplifies \gamma = k + j\omega \sqrt{LC}, so \alpha = k (constant) and v = 1 / \sqrt{LC}, eliminating phase distortion and ensuring exponential decay without waveform spreading. In practice, natural transmission lines exhibit low relative to (L/C small), leading to frequency-dependent and ; Heaviside's condition highlights the need to artificially increase L—typically via loading coils—to approximate . However, the assumes low-loss lines where R \ll \omega L and G \ll \omega C for the relevant frequencies, and real-world deviations arise from frequency-dependent parameters, such as increasing effective R at higher frequencies.

Campbell Equation

The Campbell equation provides a mathematical framework for analyzing the performance of lines with loading coils inserted at regular intervals, approximating the ideal Heaviside for distortionless propagation in lossy lines. Formulated by George A. Campbell in , it relates the of the loaded line to that of the unloaded line through the hyperbolic form derived from the infinite ladder network model. For periodic loading, the core equation is \cosh(\gamma' l / 2) \approx 1 + (Z Y l^2)/8, where \gamma' is the loaded propagation constant, l is the coil spacing, Z = R + j \omega L is the series impedance per unit length, and Y = G + j \omega C is the shunt admittance per unit length of the unloaded line. This approximation arises from the Taylor expansion of the hyperbolic cosine for small arguments (\sqrt{Z Y} l / 2 \ll 1), allowing the discrete loading to mimic the continuous distortionless behavior targeted by the Heaviside condition. The derivation begins with modeling the loaded line as an infinite symmetric ladder network, consisting of series arm impedances Z l / 2, a shunt loading coil of impedance j \omega \Delta L, and repeated sections. The voltage and current ratios across a section yield the characteristic equation \cosh(\gamma' l) = \cosh(\gamma l) + \frac{j \omega \Delta L}{2 Z_0} \sinh(\gamma l), where \gamma = \sqrt{Z Y} is the unloaded and Z_0 = \sqrt{Z / Y} is the . To minimize , the attenuation constant \alpha = \Re(\gamma') is reduced and the phase constant \beta = \Im(\gamma') is linearized over the frequency band by selecting \Delta L such that the effective per-unit-length parameters approach R / L \approx G / C. For voice frequencies, assuming negligible shunt conductance (G \approx 0) and resistance dominant at low frequencies (R \gg \omega L), the loading boosts the effective inductance to L_\text{eff} = L + \Delta L / l, flattening the group delay. In practice, for the voice band up to about 3 kHz, the spacing l is set empirically based on line parameters to ensure the lumped approximation holds, with standard designs like the H88 coil (88 mH) placed every 6,000 feet on open-wire lines with capacitance around 0.015 μF per mile, ensuring low distortion over long distances. Compared to the continuous Heaviside condition, periodic loading introduces a minor ripple in the frequency response due to the discrete structure, manifesting as small variations in \alpha and \beta near the band edges, but this approximation remains highly effective for feasible engineering implementation.

Telecommunications Applications

Telephone Lines

Loading coils are essential components in land-based telephone networks, particularly for twisted-pair cables, where they are inserted in series to compensate for signal in the voice of 300 to 3400 Hz. By adding lumped at regular intervals, these coils balance the line's electrical characteristics, counteracting the capacitive effects that cause disproportionate loss at higher voice frequencies. This implementation significantly extends the effective transmission range for voice signals, allowing clear communication over distances that would otherwise suffer from excessive . In typical installations, loading coils are placed every 3000 to 6000 feet along the twisted-pair cable, with the H88 configuration—featuring 88 millihenry (mH) inductors spaced at 6000 feet—being standard for 22-gauge wire commonly used in subscriber . This spacing approximates distributed , reducing from approximately 10 per mile at the upper end of the voice band in unloaded lines to about 1 per mile in loaded configurations, thereby maintaining consistent signal strength and intelligibility. The coils are connected in series within each wire pair, often housed in weather-resistant cases mounted on poles or in pedestals, and may include protective elements like varistors to safeguard against surges. The values and placement are selected based on the Campbell equation to optimize performance for specific wire gauges and loop lengths. However, loading coils pose significant challenges for digital subscriber line (DSL) services, as they function as low-pass filters that severely attenuate signals above 25 kHz, rendering them incompatible with xDSL technologies like and . Telephone networks thus distinguish between "loaded" loops, optimized for voice but unsuitable for , and "unloaded" loops free of coils to support higher data rates. Since the , with the widespread deployment of xDSL, telecommunications providers have systematically removed loading coils from millions of loops to enable access, a process that involves physical disconnection and often replacement with line conditioners in hybrid scenarios. In analog carrier telephony systems, such as early T1 lines multiplexing multiple voice channels, loading coils were tuned to equalize group delay and flatten the across the voice band, minimizing in multi-channel transmission. This ensured uniform propagation for all channels, supporting reliable analog over extended distances. As digital transmission standards like T1 became dominant in the late , loading coils were phased out from carrier systems, as digital signals require unloaded pairs to avoid the inductive filtering that disrupts encoding. Today, loading coils remain a legacy technology in remaining copper-based telephone networks, primarily for (POTS) in rural or underserved areas where fiber deployment lags. With the ongoing transition to fiber-to-the-premises (FTTP) and widespread xDSL upgrades, most urban and suburban loops have had coils decommissioned, rendering them obsolete in modern infrastructures and reducing maintenance needs for voice-only applications.

Submarine Cables

In the early , continuous loading was applied to submarine telegraph cables to counteract the high inherent in their insulation, which caused significant signal and over long distances. This approach involved wrapping conductors with ferromagnetic materials to introduce distributed , thereby satisfying the Heaviside condition and enabling higher transmission speeds. For voice communication, discrete loading coils were incorporated into sections, where vacuum-tube amplifiers were spaced along the cable to boost signals while the coils minimized in the band. The first Krarup loaded cable was laid in 1902 between and . A landmark implementation of continuous loading using —a high-permeability nickel-iron alloy core composed of approximately 78% nickel and 22% iron—occurred in 1924 with a cable between and the , developed by Bell Laboratories. This design spirally wound thin Permalloy tape around the copper conductors, achieving a tenfold reduction in compared to unloaded cables. The result was markedly improved over the 2,300-mile route, supporting reliable and early with minimal . During the 1930s and 1950s, and loading became standard in transatlantic submarine cables, particularly for II-era links requiring robust performance under wartime demands. These high-permeability cores, composed of nickel-iron (Ni-Fe) alloys such as 78% nickel and 22% iron for , were tape-wrapped around conductors at a typical density of approximately 1 mH/km to optimize . Such designs enabled multi-channel , including systems supporting up to 12 voice circuits, by reducing and allowing higher rates in Atlantic cables like those connecting to . , a copper-nickel-iron variant, further enhanced low-hysteresis properties for stable signal propagation in repeatered segments. To avoid the complexity and cost of full continuous loading, patch loading emerged as a targeted , employing discrete high-inductance at joints or housings. This method inserted lumped inductors—often exceeding 50 mH per —to locally compensate for capacitance-induced without altering the entire structure, proving effective for repairs and short-haul underwater extensions. By the late , loading coils became obsolete in submarine cables following the deployment of the fiber-optic system in , which revolutionized transoceanic communication with optical and vastly superior . Today, they persist only in residual legacy spurs or hybrid setups connecting remote platforms, where fiber integration is uneconomical. Environmental decommissioning efforts in the increasingly target these legacy loaded segments for removal and to mitigate clutter and recover materials like and alloys. A key challenge in loaded cables with was in the ferromagnetic cores, exacerbated by from the constant-current power feed (typically 1-2 A) used to energize vacuum-tube amplifiers. This bias saturated the cores, introducing nonlinear and increased . Mitigation involved balanced windings, where opposing coils canceled the DC flux while preserving AC , ensuring stable performance over thousands of kilometers.

Other Applications

Radio Antennas

Loading coils serve as inductive elements in radio antennas to electrically extend physically shortened radiators, enabling at desired frequencies where full-length designs are impractical. In base-loaded or center-loaded configurations, these coils add series that cancels the capacitive of short antennas, such as mobile typically less than one-quarter (λ/4) long, thereby tuning the overall impedance to approximately 50 ohms for efficient matching to standard radio equipment. For example, in vehicle-mounted antennas, base loading allows operation on lower bands like 80 meters using a compact originally sized for higher frequencies. Design principles for loading coils in antennas focus on selecting inductance values that achieve resonance while minimizing losses, often calculated to compensate for the shortened physical length relative to the wavelength. The required inductance L is given by L = \frac{1}{(2\pi f)^2 C_{eq}}, where f is the operating and C_{eq} is the equivalent of the antenna system; this balances the inductive against the antenna's capacitive component to achieve . Typical inductance values range from 10 to 50 μH for (3-30 MHz) and VHF (30-300 MHz) applications, depending on band and shortening factor—for instance, around 84 μH at 2 MHz for a 0.1λ vertical. Common types include helical coils, which offer broader due to their distributed resembling a slow-wave , and coils, prized for compactness and reduced stray fields in space-constrained setups. In , helical loading is frequently used in multi-band ham antennas, such as adapting a 10-meter for 80-meter operation by inserting a to restore , while designs suit or portable mounts where size limits apply. Performance trade-offs with loading coils include reduced , as coil losses—quantified by the —can exceed the antenna's , leading to limitations (e.g., Q values of 200-300 yield narrow tuning ranges of a few kHz on ). Compared to full-size dipoles, loaded short antennas exhibit distorted radiation patterns due to uneven current distribution across the coil, with base loading concentrating current at the and potentially elevating takeoff angles, though center loading (e.g., two-thirds up the element) mitigates this by improving current uniformity and efficiency. In modern applications, loading coils remain essential for portable and summits-on-the-air (SOTA) operations, enabling compact setups in environments like or remote activations. High-Q designs, such as those with silver-plated windings, enhance efficiency in low-power scenarios, while precise tuning is critical for digital modes like , where narrow bandwidths demand exact resonance to maintain over weak paths.

Power Transmission Lines

In power transmission systems, loading coils—commonly known as series reactors—function as large inductors connected in series with high-voltage lines to introduce additional series , aiding in reactive and overall stability for 50/60 Hz bulk . These devices are essential for long lines, where they limit short-circuit currents during faults, preventing equipment damage and enabling cost-effective network expansion without the need for extensive upgrades. For example, in a 66 system carrying a 17 MW load at 0.7 , a series reactor can reduce fault levels from 26 kA to 9.8 kA, significantly enhancing . Implementation typically features air-core, dry-type designs to avoid core saturation under high currents, with reactors placed at substations or directly in line with feeders. Inductance values range from several millihenries per phase, such as 8.2 mH in 500 kV configurations used for fault current limiting, providing reactance values around 2.5 Ω at 60 Hz to balance capacitive effects without excessive voltage drop—often limited to 1% for regulation purposes. In 500 kV lines, these reactors compensate for inherent line capacitance, supporting efficient power flow over distances exceeding 200 km. Their benefits extend to reducing the Ferranti effect, where receiving-end voltage rises under light loads, and stabilizing power swings in interconnected grids by damping oscillations and controlling load distribution. Unlike telecommunications loading coils, which operate at milliwatt levels for signal control, power transmission variants handle megawatts and prioritize high-current linearity through non-saturating air-core construction. Adoption began in the early alongside the growth of long-distance grids, evolving into standard practice for fault management. Today, they remain integral to stations and renewable integration, such as in collection lines, where they mitigate fault currents and facilitate stable interconnection with variable generation sources post-2020.

History

Theoretical Foundations

The theoretical foundations of loading coils trace back to the pioneering work of in the late , particularly his efforts to model electrical signal propagation in long transmission lines such as submarine telegraph cables. In his 1876 paper "On the Extra Current," published in the , Heaviside introduced the importance of self-induction (, L) in telegraph circuits, demonstrating how neglecting this parameter led to inaccuracies in predicting signal behavior. This work addressed gaps in earlier models by William Thomson (), whose 1855 telegraph treated signal propagation as a simple diffusive process, ignoring inductance and thus failing to account for wave-like effects in cables. Heaviside's inclusion of L enabled a more quantitative analysis of current surges, or "extra currents," caused by inductive effects during abrupt changes in voltage. Between and , Heaviside expanded this framework through a series of papers, developing a distributed-parameter model for transmission lines that incorporated (R), (L), conductance (G), and (C) per unit length. This approach predicted severe signal distortion in long cables, such as those used in , where high and low caused dispersive spreading of pulses, severely limiting transmission speeds. The context was the infamous failure of the 1858 Atlantic cable, which operated at impractically low speeds (about 1/15 ) due to unmodeled distortion, highlighting the need for frequency-dependent analysis that Heaviside's model provided. His 1884 article "The Extra Current" in The Electrician further refined the telegraph equations by integrating these parameters, laying the groundwork for understanding electromagnetic wave along lines. A central insight from Heaviside's research was that early telegraph theory's omission of produced erroneous predictions of signal and delay, particularly for higher frequencies. To counteract low natural in cables, he proposed in 1887 boosting L by incorporating iron-wire cores, though this method proved impractical for widespread use. In 1887, Heaviside published the distortionless condition in The Electrician, stating that ideal transmission occurs when the ratio of to conductance equals the ratio of to (R/G = L/C), ensuring signals propagate without shape . This condition, derived from his distributed model, directly influenced the formulation of the and provided the conceptual basis for later practical solutions like loading coils.

Invention and Development

The development of discrete loading coils for began with early efforts to enhance signal transmission over long distances. In 1897, John Stone Stone, an engineer at the American Telephone and Telegraph Company (), secured U.S. 575,275 for an "Electric Circuit" that incorporated spaced inductors along telegraph lines to increase and reduce , marking an initial practical approach to periodic loading using bi-metallic wire configurations. This work laid groundwork for subsequent inventions, though it focused primarily on continuous rather than discrete coil elements. Building on theoretical foundations from , George A. Campbell at derived the for periodic loading starting around 1897, with key work between 1899 and 1903, demonstrating that inductors placed at regular intervals could approximate the Heaviside condition to minimize signal distortion. Campbell conducted the first laboratory tests using artificial lines that simulated real cable sections, confirming reduced for voice frequencies through iterative coil placement and calculations. His internal memos documented these experiments, emphasizing optimal coil values to balance and without excessive signal cutoff. Independently, Michael I. Pupin at arrived at similar derivations for coil spacing in 1899–1900, focusing on discrete inductors to counteract in long lines. Pupin secured U.S. 652,230 in 1900 for the "Art of Reducing of Electrical Waves and Apparatus Therefor," describing "artificial" loading with spaced coils to extend transmission range. He presented key findings in a 1901 paper to the (AIEE), detailing resonance effects and practical implementation. Initial field trials followed, including AT&T's 1902 installation on the Boston-to-New York line, where coils improved clarity over 200 miles. Technical refinements during this period addressed coil construction, with debates centering on air-core designs for lower losses versus iron-core types for higher density. Engineers like Campbell and Pupin optimized spacing at approximately 3,000 feet for 22-millihenry coils, balancing reduction with minimal limitation for voice signals around 2–3 kHz. These advances enabled reliable over distances previously limited to about 20 miles without .

Patent Disputes and Adoption

The development of loading coils faced significant patent challenges in the early 1900s, primarily through an interference proceeding in the U.S. between Michael Idvorsky Pupin of and George Ashley Campbell of . Campbell had conducted secret tests on loading coils as early as 1899, but his formal was filed later, around 1903, for related work. Pupin filed his application on December 14, 1899. The proceeding, initiated in August 1900, examined priority of invention, with arguing that Campbell's practical experiments and theoretical work predated Pupin's. from Oliver Heaviside's 1887 distortionless transmission theory and John Stone's 1897 patent on loaded cables was cited during appeals, including those in 1912, to establish precedence, but the ultimately ruled in Pupin's favor in 1904, validating his primary patent (U.S. Patent No. 652,230) for the "Art of Reducing of Electrical Waves and Apparatus Therefor." To resolve the dispute and consolidate control over the technology, negotiated a settlement with Pupin starting in December 1900, acquiring exclusive rights to his for an initial payment of $50,000 plus annual fees and royalties, totaling approximately $435,000 over 20 years—equivalent to about $15 million in 2025 dollars. This agreement incorporated complementary designs, such as optimal coil spacing based on the Heaviside condition, avoiding further litigation and enabling to commercialize the invention without royalties to external parties. The resolution, finalized by 1901, marked a pivotal shift from conflict to proprietary dominance for . The acquisition facilitated rapid adoption by , dramatically extending telephone transmission ranges by compensating for signal and . Loading coils doubled the effective distance for intelligible speech, from roughly 1,000 miles to over 2,000 miles on open-wire lines. A landmark demonstration occurred in with the opening of a 2,100-mile loaded between and , using coils spaced every 8 miles, which showcased reliable coast-to-coast potential without intermediate . By 1915, AT&T had deployed loading coils on thousands of miles of toll lines, installing them at intervals of 4 to 8 miles depending on wire gauge, fundamentally transforming long-distance and supporting the growth of the network. Globally, licensed the technology through its manufacturing arm, , promoting widespread adoption in international networks. In , loading coils were integrated into the 1910 Anglo-French submarine telephone cable across the between and , where they were embedded directly into the cable design to enhance voice transmission over 25 miles of underwater line. This application demonstrated the versatility of Pupin-Campbell coils for cable systems, reducing the need for thicker conductors and enabling clearer precursors. The economic impact was profound; estimated savings of approximately $100 million in the early by minimizing usage and installations, equivalent to billions in modern terms, while accelerating network expansion. By the post-World War I era, control of loading coil technology remained consolidated under , with cross-licensing agreements ensuring U.S. dominance. Internationally, the International Telegraph Union (ITU, formerly CCIT) formalized standards in the , including specifications for loading coils in telephone cables adopted at the 1928 Paris plenary session, which standardized values (e.g., 88 mH for 26-gauge wire) and spacing to harmonize global interoperability and facilitate cross-border circuits. These standards solidified loading coils as a of analog infrastructure until the rise of digital systems in the late .

References

  1. [1]
    Art of reducing attenuation of electrical waves and apparatus therefor.
    PUPIN, OF YONKERS, NEIV YORK. ART OF REDUCING ATTENUATlON OF ELECTRICAL WAVES AND APPARATUS THEREFOR. SPECIFICATION forming part of Letters Patent No. 652,230, ...
  2. [2]
    On Heaviside's contributions to transmission line theory - Journals
    Oct 29, 2018 · This paper surveys some selected contributions of Oliver Heaviside FRS (1850–1925) to classical electromagnetic theory and electrical engineering science.<|control11|><|separator|>
  3. [3]
    George Campbell - Engineering and Technology History Wiki
    Aug 9, 2017 · Following the theoretical groundwork laid by Oliver Heaviside in 1887, Campbell began developing the loading coils that would keep the signal ...
  4. [4]
    NIHF Inductee Michael Pupin Invented Loading Coils
    Loading Coil for Long Distance Telephony. U.S. Patent No. 761,995. Inducted in 2011. Born Oct. 4, 1858 - Died March 12, 1935. Michael Pupin, born Mihailo Pupin ...
  5. [5]
    [PDF] load coils.qxd - Charles Industries
    Load coils reduce the effective capacitance of the extended copper loop, adding inductance to cancel high-frequency spectrum capacitance in order to balance the ...Missing: definition history
  6. [6]
    None
    No readable text found in the HTML.<|control11|><|separator|>
  7. [7]
    Oliver Heaviside | Research Starters - EBSCO
    In 1885, Heaviside applied Maxwell's equations to electrical transmission lines to obtain the modern form of the telegrapher's equations. He applied these ...
  8. [8]
    [PDF] XXX. On loaded lines in telephonic transmission
    Dec 9, 2010 · Heaviside stated in 1893 that there was "no direct evidence of the ... A cross-sP.ction of this loading coil, known as the T-14 coil ...
  9. [9]
    [PDF] The struggle for the range of telephone communication before the ...
    While waiting for the delivery of coils (June 1899), he derived a theoretical equation for the loaded line, which became known as the “Campbell's equation”:.
  10. [10]
    Telephone Transmission - Engineering and Technology History Wiki
    May 2, 2015 · Since inductors resist changes in current, these loading coils reduced attenuation by increasing induction. This increased the distance over ...
  11. [11]
    Cable loading (Floyd Davidson)
    That is 88 millihenry >>>torroidal load coils. They are ... LOAD SPACING LOAD COILS LETTER SPACING NUMBER ACTUAL DESIGNATOR FEET DESIGNATOR INDUCTANCE ...
  12. [12]
    Loading Open Wire Lines
    Placing loading coils into cable circuits increases inductance, thus reduces the speed of voice and carrier currents. In fact, for voice frequency circuits, ...Missing: definition | Show results with:definition
  13. [13]
    Fiber Optic Data Communications for the Premises Environment
    Thus, loading coils prevent DSL connections. Loaded Loop - A loop that contains series inductors, typically spaced every 6 ft. for the purpose of improving ...
  14. [14]
    [PDF] Florida Public Service Commission White Paper on Network Access ...
    Aug 14, 2000 · The loading coils amplify noise which interferes with the DSL signal and causes disconnection. Two types of DSL services are available today: ...
  15. [15]
    T-carrier and SONET - Peter Lars Dordal
    A group of 12 T1 frames is called a superframe; the framing bit is used to encode a special bit-pattern, eg 0101 1101 0001, that can be used to identify ...
  16. [16]
  17. [17]
    [PDF] 0wn?Atmiul1Lrn:© OOMllMlmJJNil TI@N - World Radio History
    The new cable is loaded continuously, correspo ding in this respect to the method of Krarup, but the properties of the new loading material,. "Permalloy," are ...
  18. [18]
    [PDF] Submarine cables and the oceans: connecting the world
    Alloy tapes and wires, such as the iron- nickel, permalloy, and the copper-iron-nickel, mu-metal, were used to increase cable performance (particularly the.Missing: Fe | Show results with:Fe
  19. [19]
    [PDF] Handbook – Optical fibres, cables and systems - ITU
    Moreover there are two passive nodes that are specific to submarine cables: the submarine repeater housing and the branching Unit. 6.2.1 The submarine repeater ...
  20. [20]
    Home - Subsea Environmental Services (SES)
    Since 2014, Subsea Environmental Services has been recovering Out-of-Service (OOS) submarine telecommunication cables from the seabed and recycling their ...Missing: 2020s segments
  21. [21]
    [PDF] Dennis Albert Analysis of Power Transformers under DC/GIC Bias
    The DC bias mitigation effect of a delta winding is analysed on a measurement example and new DC mitigation setup is proposed in Section 4.7. The effects of ...
  22. [22]
    [PDF] A practical approach to HF and VHF antennas, plus antenna ... - ARRL
    This Bug Catcher mobile antenna has a capacitive “top hat” installed above the loading coil to reduce the number of turns required on the loading coil. This ...
  23. [23]
    Tuning Electrically Short Antennas for Field Operation is Research ...
    Jun 14, 2019 · Rohde told ARRL that loading coil placement in a short vertical antenna is critical, and “the greater the elevation of the coil, the better the ...Missing: function | Show results with:function
  24. [24]
    80-Meter Base-Loaded Mobile Antenna - eHam.net
    Nov 2, 2019 · Having a bottom section under the loading coil (center-loading) complicates the analysis by introducing an additional negative phase shift at ...Missing: function | Show results with:function
  25. [25]
    Impedance Measurements on Loading Coils - eHam.net
    Mar 22, 2015 · Impedance measurements are used to determine the characteristics of a piece of transmission line. The same measurement techniques are applicable to air-core ...
  26. [26]
    How Does an Inductor or Loading Coil Work? - W8JI
    A physically small loading coil simply inserts a series inductive reactance that cancels capacitive antenna reactance. When a 150-ohm reactance inductor is ...
  27. [27]
    Current distribution in the Antenna Loading Coils. - eHam.net
    The current in a typical loading coil in the shortened antennas drops across the coil roughly corresponding to the segment of the radiator it replaces. ... and ...
  28. [28]
    [PDF] Determining Short HF Antenna Efficiency - QSL.net
    High-Q Coil Loss is Almost TWICE the Radiation Resistance. With a PERFECT ground, you still lose 2/3rds of your power do to the coil loss! Your antenna is 34% ...Missing: factor | Show results with:factor
  29. [29]
    [PDF] core series reactors - GE Vernova
    This technology allows compact coils for high inductance, reducing the installation footprint. High-power series reactors usually present high impedance and.
  30. [30]
    Analysis of influence of a novel inductive fault current limiter on the ...
    May 4, 2021 · The inductance of the 500 kV FCL in series with the circuit is 8.2 mH, whereas the equivalent inductance of the voltage source is 10.2 mH.
  31. [31]
    Series reactors - Hitachi Energy
    Hitachi Energy's series reactors are usually the magnetically shielded air core design, the electromagnetic coil is connected in series in the electric circuit.
  32. [32]
    Air Core Series Reactors | Trench Group
    Air core series reactors strategically connected in series with high voltage transmission lines effectively reduce fault current thereby enhancing the overall ...
  33. [33]
    [PDF] XIX. On the extra current - Zenodo
    May 13, 2009 · Oliver Heaviside. To cite this article: Oliver Heaviside (1876) XIX. On the extra current , Philosophical Magazine. Series 5, 2:9, 135-145 ...Missing: distortion | Show results with:distortion
  34. [34]
  35. [35]
    NIHF Inductee George Campbell Invented the Electronic Filter
    An important result of his theories on loading coils was Campbell's development of wave filtering in 1910.Missing: date | Show results with:date
  36. [36]
    [PDF] The Bell System Technical Journal April, 1926 Development and ...
    Dr. G. A.. Campbell in his paper5 of March, 1903, also gave a mathematical de- velopment of the loading theory along somewhat different lines.<|control11|><|separator|>
  37. [37]
    The Introduction of the Loading Coil: George A. Campbell and ... - jstor
    The coil-loaded telephone circuit may seem deceptively simp. since it consists of inductance coils connected in series with the. conductors of telephone wires ...Missing: telecommunications | Show results with:telecommunications
  38. [38]
    Oral-History:Lloyd Espenschied
    Jan 26, 2021 · Within a few short years, Espenschied went on to invent a new kind of loading coil. By 1915, he was involved in high-frequency wire transmission ...
  39. [39]
    Loading Coils, The Heaviside Condition, And Pupin Coils | Hackaday
    Jun 19, 2020 · The first transatlantic cable went into service in 1858 and was virtually the moon landing of its day. Frustrated with how slow the communications were.
  40. [40]
    Michael Pupin and Pupinization of Telephone Lines - ResearchGate
    Aug 8, 2025 · Attention is paid to the dispute between Pupin and Campbell in the primacy of the invention of load coils and its most significant consequences.
  41. [41]
    Bell Telephone System, 1875-1915 - jstor
    dissertation based on his loading-coil studies. It is worth noting in passing how Campbell's work on the loading coil provides a working example of the ...<|separator|>
  42. [42]
    1910 Anglo-French Telephone Cable
    Oct 2, 2008 · Easing a Loading Coil over the Sheaves. The cable was paid into the Faraday's tank on the 2nd and 3rd of May, 1910, and the ship left ...
  43. [43]
    [PDF] C.C.I.F. Pleanry Session: Documents (Paris, 1928)
    Essential Clauses for a Typical Specification of general application to Loading Coils for International Telephone Cables .. .. .. .. Housing ...