Fact-checked by Grok 2 weeks ago

Maximum operating depth

Maximum operating depth (MOD) is the deepest depth at which a can safely use a specific mixture, determined by the point where the of oxygen (pO₂) reaches a predetermined maximum limit to prevent . In , this limit is typically 1.4 atmospheres absolute () for the bottom phase of a dive and 1.6 ATA during decompression stops, based on standards from organizations like the (NOAA) and the Divers Alert Network (). Exceeding the MOD risks () , which can cause convulsions, loss of consciousness, and . The MOD is calculated using the formula: depth (in feet of seawater) = [ (maximum pO₂ / fraction of oxygen in the mix) - 1 ] × 33, accounting for atmospheric pressure at the surface and the compressibility of seawater. For example, with air (21% oxygen) at a 1.4 ATA limit, the MOD is approximately 187 feet (57 meters); for enriched air nitrox with 32% oxygen, it drops to about 111 feet (34 meters). These calculations are essential for technical and recreational diving, where divers must label cylinders with the gas mix and MOD, and use dive computers or tables to monitor adherence. Training agencies like PADI and NOAA emphasize MOD planning to integrate with no-decompression limits and gas management strategies. Beyond , the term applies to other underwater operations, such as , where it denotes the depth not to exceed during routine missions, determined by strength and naval specifications, which vary by and are often classified. In remotely operated vehicles (ROVs) and submersibles, it specifies equipment-rated depths, like 4,000 meters for deep-sea profilers, to ensure structural integrity under . Across contexts, balances operational needs with safety margins against hydrostatic effects.

Fundamentals

Definition

Maximum operating depth (MOD) is the maximum depth at which a can safely operate using a particular mixture without exceeding the recommended of oxygen (PPO₂). This depth represents the limit beyond which the oxygen component in the gas mix would pose an unacceptable risk due to increasing . MOD is primarily applied in , systems, and operations. These contexts rely on MOD to guide gas selection and dive planning, ensuring the breathing mixture remains suitable for the planned depth profile. The value of MOD is expressed in meters of (msw) or feet of seawater (fsw), which account for the absolute equivalent of hydrostatic head in seawater.

Importance in Diving

The maximum operating depth (MOD) plays a central role in dive planning by establishing safe depth limits for specific breathing gas mixtures, which directly influences the selection of gas types, dive profiles, required decompression stops, and equipment configurations such as regulators and cylinders. Divers must calculate or reference the MOD before a dive to ensure the chosen gas—whether air, nitrox, or trimix—remains within acceptable physiological parameters throughout the planned depth range, thereby optimizing bottom time and minimizing risks associated with deeper excursions. Exceeding the MOD poses severe safety implications, primarily the risk of (CNS) oxygen toxicity, which can lead to convulsions underwater and subsequent drowning. Major diving certification agencies, including PADI, NAUI, and TDI, incorporate MOD guidelines into their training standards and protocols to enforce these limits, requiring divers to verify gas analysis and depth adherence as core safety practices. The concept of was formalized in the 1970s alongside the adoption of for and , driven by efforts from organizations like NOAA to extend safe operational depths while managing oxygen exposure. It further evolved in the with the rise of standards, which integrated MOD into advanced protocols for mixed-gas dives beyond recreational limits. In practical applications, MOD is embedded in dive tables and modern dive computers, which provide real-time depth monitoring and audible or visual alerts to prevent inadvertent exceedance, allowing divers to maintain awareness during descent and ascent. This integration enhances overall dive safety by automating enforcement of depth boundaries tailored to the gas mixture in use.

Physiological Basis

Oxygen Partial Pressure

In , the partial pressure of oxygen (PPO₂) refers to the pressure exerted by oxygen molecules within a of gases, governed by , which states that the total pressure of a gas equals the sum of the partial pressures of its individual components. This is calculated as the product of the total and the fraction of oxygen (FO₂) in the gas , such that PPO₂ = total pressure × FO₂; for example, in air with an FO₂ of 0.21 at , the PPO₂ is approximately 0.21 atmospheres. The concept is fundamental to understanding gas behavior under pressure, as each gas in the acts independently regardless of the others. Hydrostatic pressure in water increases linearly with depth due to the weight of the overlying water column, adding approximately 1 atmosphere (atm) for every 10 meters of seawater (msw) or 33 feet of seawater (fsw) descended. At the surface, the ambient pressure is 1 atm from atmospheric pressure alone, but as depth increases, the total pressure rises accordingly—for instance, at 10 msw, the total pressure becomes 2 atm (1 atm atmospheric + 1 atm hydrostatic). This escalation compresses the breathing gas, elevating the partial pressures of all constituent gases, including oxygen, and thereby influencing their physiological effects on the diver. Partial pressures in diving are conventionally measured in atmospheres absolute (ata), a unit that accounts for both atmospheric and hydrostatic components of total pressure. At the surface, 1 ata equals standard atmospheric pressure (approximately 101.3 kPa or 14.7 psi), and it increases directly with depth; for example, at 20 msw, the total pressure is 3 ata. This absolute scale ensures consistent quantification of gas pressures across varying depths and environments. The PPO₂ is critical for oxygen delivery to tissues, as it determines the gradient driving oxygen from the alveoli into the bloodstream and subsequently to body tissues via , where higher partial pressures increase dissolved oxygen levels in fluids. In hyperbaric conditions, elevated PPO₂ enhances oxygen availability but risks if unchecked, underscoring its role in establishing maximum operating depth as the limit for maintaining safe oxygen exposure.

Toxicity Risks and Limits

Oxygen toxicity in diving manifests primarily in two forms: pulmonary oxygen toxicity and (CNS) oxygen toxicity, both arising from elevated partial pressures of oxygen (PPO₂). Pulmonary oxygen toxicity typically occurs at PPO₂ levels exceeding 1.4 atmospheres absolute () during prolonged exposures, leading to lung irritation characterized by symptoms such as substernal discomfort, coughing, and a burning sensation upon inhalation, which can reduce pulmonary function. In contrast, CNS oxygen toxicity is more acute and dangerous, often triggered at PPO₂ above 1.6 , resulting in neurological symptoms including , muscle twitching, , , and potentially convulsions or seizures that pose an immediate risk underwater. To mitigate these risks, diving organizations have established PPO₂ limits based on exposure duration and activity level. For , a maximum PPO₂ of 1.4 is widely recommended during the working phase of the dive to prevent both pulmonary and CNS effects. In , limits range from 1.3 to 1.6 , adjusted for factors like exposure time; for instance, the (NOAA) guidelines (pre-2025) permit up to 45 minutes at 1.6 , 120 minutes at 1.5 , and 150 minutes at 1.4 for single exposures, with a 24-hour cumulative cap. In September 2025, NOAA revised its CNS guidelines, extending the limit at 1.3 to 240 minutes for the working phase of a dive and an additional 240 minutes during , based on updated . The British Sub-Aqua Club (BSAC) aligns closely, advocating a 1.4 limit for active portions and up to 1.6 for , emphasizing reductions in cold water or high exertion. Several factors influence the onset of oxygen toxicity, including exposure duration, physical workload, elevated (CO₂) levels from exertion or equipment issues, and individual physiological variability, which can accelerate symptom development at lower PPO₂ thresholds. To manage cumulative risks across multiple dives, NOAA Oxygen Exposure Tables track CNS clock percentages, where time at a given PPO₂ contributes proportionally to a daily total not exceeding 100% (e.g., 150 minutes at 1.4 equals 100%), allowing divers to plan safely without exceeding toxicity thresholds. Historical incidents, particularly hyperbaric chamber accidents in the early —such as Bornstein's experiments exposing volunteers to 2.8 PPO₂, which were tolerated without adverse effects—highlighted the dangers of high oxygen levels, prompting initial safety protocols in . These guidelines evolved significantly in the through research, including NOAA's 1985 introduction of enriched air training programs, which refined exposure limits based on empirical data to balance benefits against risks in recreational and contexts.

Calculation Methods

Core Formula

The core formula for calculating the maximum operating depth () of a mixture in is derived from the relationship between the fraction of oxygen (FO₂) in the gas and the safe partial pressure of oxygen (PPO₂). It determines the depth at which the PPO₂ reaches a predetermined safe limit to prevent . The formula in metric units (meters of , msw) is: \text{MOD (msw)} = \left( \frac{\text{Safe PPO}_2}{\text{FO}_2} - 1 \right) \times 10 Here, Safe PPO₂ is the maximum acceptable absolute partial pressure of oxygen, typically 1.4 atmospheres absolute (ata) for working depths in recreational and many technical dives to minimize central nervous system (CNS) oxygen toxicity risk, while FO₂ is the decimal fraction of oxygen in the breathing gas (e.g., 0.21 for air). The subtraction of 1 accounts for the 1 ata of atmospheric pressure at the surface, and the factor of 10 assumes a linear pressure increase of 1 ata per 10 meters of seawater depth, based on standard seawater density. In (feet of , fsw), the equivalent formula uses 33 fsw per : \text{[MOD](/page/MOD) (fsw)} = \left( \frac{\text{Safe PPO}_2}{\text{FO}_2} - 1 \right) \times 33 This adjustment reflects the approximate 33-foot depth per in . For example, using air (FO₂ = 0.21) and a safe PPO₂ of 1.4 yields an of approximately 57 msw (or 187 fsw), representing the theoretical limit before exceeding the oxygen threshold.

Derivation and Assumptions

The derivation of the maximum operating depth (MOD) begins with of partial pressures, which states that the partial pressure of oxygen (PPO₂) in a mixture is the product of the fraction of oxygen (FO₂) and the total absolute pressure at depth. The absolute pressure in atmospheres absolute (ata) is given by 1 ata (surface pressure) plus the hydrostatic pressure, approximated as depth in meters divided by 10 for . Thus, PPO₂ = [1 + (depth / 10)] × FO₂, where the inequality PPO₂ ≤ safe PPO₂ (typically 1.4 ata for or 1.6 ata for technical exposures) sets the limit to prevent . Solving for depth yields: \text{Depth (m)} = 10 \times \left( \frac{\text{safe PPO₂}}{\text{FO₂}} - 1 \right) This formula converts the ata-based pressure to meters using the standard 10 m per ata hydrostatic gradient. Key assumptions underlying this derivation include a constant FO₂ throughout the dive, neglecting any effects from gas consumption or analyzer drift. Calculations assume seawater with a specific gravity of 1.025–1.026 relative to freshwater, which yields the 10 m/ata conversion; freshwater dives require adjustment to approximately 9.9 m/ata. The model also ignores variations in water temperature and salinity, which can alter density and thus hydrostatic pressure by up to 2–3% in extreme cases. Limitations of the MOD formula include its static nature, which does not account for dynamic factors such as rapid ascent or descent rates that could transiently exceed safe PPO₂, or switches between multi-gas mixtures during a dive. It provides accuracy within 1–2% for most planned recreational or technical dives under steady-state conditions but requires real-time monitoring with dive computers for precision. For altitude diving above 300 m (1,000 ft), the MOD must be reduced by the ratio of local atmospheric pressure to sea-level pressure (e.g., approximately 0.8 at 2,400 m), as lower surface pressure decreases the available margin before reaching toxic PPO₂ levels. This formula and its assumptions evolved from 1960s U.S. Navy research, including Sealab experiments and early mixed-gas tables that established oxygen partial pressure limits based on manned hyperbaric exposures.

Practical Applications

Standard Gas Mixtures

Air, the standard for recreational , consists of 21% oxygen (O₂) and has a maximum operating depth (MOD) of 56–58 meters of (msw) or 184–190 feet of (fsw) when limited to a of oxygen (PPO₂) of 1.4 atmospheres absolute (ata). This gas is widely used due to its availability and simplicity but is often restricted in practice by , with effects typically beginning at depths around 30 msw, leading to recommended recreational limits of 40 msw or shallower. Enriched air nitrox (EAN) blends, which increase the oxygen fraction to reduce nitrogen content, provide shallower MODs while extending no-decompression limits and minimizing decompression obligations compared to air. Common recreational blends include EAN32 (32% O₂), with an MOD of 34 msw (111 fsw) at 1.4 ata PPO₂, and EAN36 (36% O₂), with an MOD of 29 msw (95 fsw) at the same limit. These standard mixtures are certified for recreational diving applications, typically confined to depths under 40 msw, with dive planning tables from organizations like PADI detailing MOD values relative to the fraction of oxygen (FO₂) to ensure safe PPO₂ management. A higher contingency PPO₂ of 1.6 ata may be applied for brief deeper exposures, allowing slightly greater depths within the same gas mix.
Gas MixtureFO₂ (%)MOD at 1.4 ata (msw / fsw)MOD at 1.6 ata (msw / fsw)
Air2157 / 18767 / 220
EAN303037 / 12143 / 143
EAN323234 / 11140 / 132
EAN363629 / 9535 / 114
EAN404025 / 8330 / 100
Note: Air MOD values are based on physiological limits beyond typical recreational constraints; nitrox values follow PADI guidelines.

Custom and Technical Blends

In technical diving, trimix—a blend of oxygen, nitrogen, and helium—enables operations at depths beyond those feasible with air or nitrox by mitigating both oxygen toxicity and inert gas narcosis through helium substitution. The MOD for a trimix is governed by the most restrictive limit, typically the oxygen partial pressure (PPO2) ceiling or helium-related constraints such as central nervous system (CNS) oxygen toxicity equivalents. For instance, a Tx17/50 trimix (17% oxygen, 50% helium, balance nitrogen) yields an MOD of approximately 76 meters of seawater (msw) at a PPO2 of 1.46 atmospheres absolute (ata), as demonstrated in early planning examples for 250 feet seawater (fsw) dives. Heliox, composed solely of oxygen and , facilitates very deep dives exceeding 100 msw, leveraging 's negligible potency to extend operational limits while necessitating stringent PPO2 monitoring to prevent risks. This mixture has supported dives to 600 msw in experimental contexts, though practical applications prioritize PPO2 limits around 1.4 to balance depth and safety. Precise MOD determination for custom trimix and blends relies on planning software tailored to mixed-gas profiles, such as V-Planner and MultiDeco, which integrate gas fractions, depths, and physiological models to compute safe operating envelopes. Standards from organizations like Global Underwater Explorers (GUE) and International Association of and Divers (IANTD) advocate PPO2 limits of 1.2-1.4 for bottom gases during deep exposures, ensuring conservative margins for prolonged bottom times. Notable applications of optimized trimix blends appear in 1990s expeditions pioneering deep , such as those exploring underwater caves and wrecks, where custom mixes like normoxic and hypoxic trimix extended to 100 msw or greater, enabling systematic penetration and documentation previously limited by air's constraints. The practical applications of trimix have continued to evolve, with the deepest recorded open-circuit dive reaching 332.35 meters using trimix in the in 2014.

Extensions and Variations

Multi-Gas Considerations

In multi-gas diving profiles, such as those employed in technical decompression dives, the maximum operating depth (MOD) is calculated individually for each gas mixture used across dive segments to manage oxygen partial pressure (pO₂) exposure. The bottom gas, typically a helium-enriched trimix for deep phases, determines the initial MOD based on a conservative pO₂ limit of 1.4 atmospheres absolute (ata) during active diving, allowing descent to the planned working depth without exceeding toxicity thresholds. As the diver ascends, switches occur to shallower MOD gases, such as oxygen-enriched nitrox blends for decompression, which operate at higher pO₂ limits up to 1.6 ata during rest phases to accelerate off-gassing while minimizing central nervous system (CNS) oxygen toxicity risks. Travel gases serve as intermediate blends to facilitate safe transitions between and decompression mixtures, particularly when dealing with hypoxic bottom gases containing less than 16% oxygen that would be unsafe near . These travel mixes, often a balanced or trimix, are selected to ensure their aligns with the switch depth, preventing pO₂ excursions during ; for instance, a 21/35 trimix (21% oxygen, 35% ) might bridge depths from 60 meters to 30 meters without violating segment-specific limits. Proper planning ensures no portion of the ascent exceeds the of the active gas, maintaining overall profile safety. Technical diving protocols emphasize pre-dive MOD verification for every through analysis and labeling, often using standardized systems like TDI's MODS (Mix, Open, Depth, Switch) to confirm contents, functionality, and depth compliance before each switch. Dive planners, such as software tools or computer algorithms, track cumulative inert gas loading and pO₂ exposure across segments, alerting divers to switch points and ensuring alignment with the model. Team communication, including buddy verification and , is integral to these protocols to mitigate errors under task loading. Challenges in multi-gas operations include bailout scenarios, where rebreather or open-circuit failures necessitate immediate switching to an , potentially at depths violating its and risking acute . For example, deploying a high-oxygen bailout mix like 50% at 60 meters could yield a pO₂ exceeding 3 , leading to convulsions; protocols require bailout gases to be planned with progressive s matching potential failure depths. In , real-world adjustments for and oxygen flow rates are critical to maintain setpoints during transitions, as variable work rates or currents can alter gas consumption and pO₂ stability, necessitating manual flushes or additions to avoid or . Equivalent Narcotic Depth (END) is a calculated metric used in to estimate the equivalent depth at which a would experience the same level of as when breathing air, adjusted for the lower potency of in mixtures like trimix. This allows to manage narcosis risks by substituting for part of the , effectively reducing the of gases at depth. The for END is END = [FN2 × (depth in msw + 10) / 0.79] - 10, where depth is the actual diving depth in meters of seawater (msw), FN2 is the fraction of in the , 10 accounts for surface in msw, and 0.79 represents air's fraction ( potency reference); this assumes as the primary gas (some sources include oxygen or use approximations). By keeping END below recreational limits like 30-40 msw, can maintain cognitive function during deep exposures, such as in trimix dives beyond 50 msw. For helium-dominated mixtures like , maximum operating depth () extends beyond oxygen constraints due to helium's inert nature, but it is primarily limited by (), a characterized by tremors, myoclonic jerks, and cognitive impairments that onset during rapid descents beyond 150 msw. arises from helium's effects on nerve conduction at extreme pressures, typically manifesting above 150-200 msw, and can persist or worsen beyond 330 msw even with slow compression rates. In , reaches approximately 300 msw, where operations balance risks through controlled descent profiles and occasional nitrogen addition to mitigate symptoms, enabling extended bottom times for commercial tasks like pipeline inspection. Beyond physiological gas limits, absolute depth constraints arise from equipment capabilities, such as standard recreational cylinders (e.g., AL80 at 3,000 psi), which practically limit single-tank dives to around 100 msw due to rapid gas consumption and performance under high . These hardware limits integrate with MOD calculations to define overall dive profiles, ensuring sufficient reserve gas and equipment integrity; for instance, exceeding 100 msw often requires staged and multiple tanks to avoid reserve depletion. In practice, END frequently imposes shallower practical limits than oxygen-based MOD in trimix dives, as narcosis management prioritizes mental clarity over oxygen toxicity in the 60-100 msw range; for example, a trimix with 15% oxygen and 20% nitrogen might yield an END of approximately 20 msw at 80 msw actual depth, guiding mix selection. This interplay evolved historically in the post-1980s era, when trimix adoption in technical diving—pioneered by figures like Sheck Exley—shifted depth norms from air's 50 msw ceiling to 100+ msw through refined gas modeling and END standardization, reducing accident rates in exploratory wrecks and caves.

References

  1. [1]
    Breathing Gases - Divers Alert Network
    May 1, 2017 · Maximum Operating Depth. The maximum operating depth (MOD) of a gas mix is determined by calculating the depth at which the partial pressure of ...
  2. [2]
    None
    Below is a merged summary of the NOAA Diving Standards & Safety Manual (May 2023) based on the provided segments. To retain all information in a dense and organized format, I will use a combination of narrative text and tables in CSV format where appropriate. The response consolidates all details across the segments, avoiding redundancy while ensuring completeness.
  3. [3]
    Max depth - Confédération Mondiale Des Activités Subaquatiques
    Aug 15, 2025 · Narcosis is “progressive from a depth of 35 to 60 m when diving with air, with no threshold effect, and systematic beyond 60 m” (PpN2 > 5.6 ATA) ...
  4. [4]
    Enriched Air Nitrox: Why This Should Be Your Next Specialty
    Jul 25, 2018 · Maximum Operating Depth (MOD): The maximum depth at which to use any given mix to avoid oxygen toxicity, and why Nitrox divers should choose ...Missing: definition | Show results with:definition
  5. [5]
    Maximum operating depth - The Free Dictionary
    maximum operating depth. The keel depth that a submarine is not to exceed during operations. This depth is determined by the submarine's national naval ...
  6. [6]
    Deep NINJA | It can observe the deep ocean up to 4,000 m depth ...
    Specifications of Deep NINJA ; Maximum operating depth:4,000dbar(~4,000m) ; Size:210 cm long and 50 kg in air ; Sensor:SBE41CP for deep float (Sea-Bird Electronics ...<|control11|><|separator|>
  7. [7]
    maximum operating depth (US DoD Definition) - Military Factory
    Official definition of the United States Department of the term maximum operating depth .
  8. [8]
    [PDF] Dive Safety 2010
    MOD - Maximum Operating Depth, usually determined as the depth at which the pO2 for a given gas mixture reaches a predetermined maximum. MSW - Meters of ...
  9. [9]
    [PDF] Dive Operations Handbook, U.S. Fish and Wildlife Service
    Maximum Operating Depth (MOD) – The diving depth at which the Partial Oxygen Content (PO2) for a given mixture reaches a pre-determined level, not to exceed ...
  10. [10]
    Closed-Circuit Rebreathers: A Different Way to Dive
    Nov 1, 2009 · ... maximum operating depth (MOD) of the gas they are breathing. CCR divers also need to be especially careful of rapid descents or ascents as ...
  11. [11]
    3 Tips for Diving Nitrox Safely - - SDI | TDI
    Nitrox has depth limitations because it increases the risk of oxygen toxicity, among other issues. It is a common misconception that Nitrox benefits deep divers ...
  12. [12]
    Nitrox - Divers Alert Network
    Nov 1, 2011 · The gas mix was developed based on two criteria: a maximum operating depth of 130 feet and a maximum oxygen partial pressure of 1.6 atmospheres ...Missing: authoritative source
  13. [13]
    Nitrox in Sport Diving: How It All Began | X-Ray Mag
    A diver breathing a gas mixture containing 32% oxygen would be breathing a pO2 of 1.6 at 132ft (40m), and 130ft was the maximum depth limit for the NOAA diving ...
  14. [14]
    Nitrox Diving Safety - Divers Alert Network
    May 1, 2018 · This finding seemed counterintuitive at first, since the safe maximum operating depth of nitrox ... dive computer's recorded profile. The ...<|control11|><|separator|>
  15. [15]
    Diving and oxygen - PMC - NIH
    At higher partial pressures oxygen causes acute toxicity leading to convulsions. To understand the diver's narrow knife edge between fatal hypoxia and fatal ...
  16. [16]
    Scuba Diving Physiology - StatPearls - NCBI Bookshelf
    Jan 22, 2025 · The partial pressure of a particular gas constituent in a gas mixture represents the portion of the total pressure exerted by the specific ...
  17. [17]
    How does pressure change with ocean depth?
    Jun 16, 2024 · The deeper you go under the sea, the greater the pressure of the water pushing down on you. For every 33 feet (10.06 meters) you go down, the pressure ...
  18. [18]
    Water Pressures at Ocean Depths - NOAA/PMEL
    The pressure increases about one atmosphere for every 10 meters of water depth. At a depth of 5,000 meters the pressure will be approximately 500 atmospheres ...
  19. [19]
  20. [20]
    Oxygen Toxicity - StatPearls - NCBI Bookshelf - NIH
    Pulmonary effects can present as early as within 24 hours of breathing pure oxygen. Symptoms include pleuritic chest pain, substernal heaviness, coughing, and ...
  21. [21]
    Emergency Oxygen and Oxygen Toxicity - Divers Alert Network
    Aug 10, 2022 · Symptoms may include substernal (behind the sternum) irritation, coughing, a burning sensation with inspiration and reduced pulmonary function.
  22. [22]
    Oxygen Toxicity - Divers Alert Network
    Signs and Symptoms · Flashing lights in front of your eyes · Tunnel vision · Loud ringing or roaring in the ears (tinnitus) · Confusion · Lethargy · Nausea and ...
  23. [23]
    Oxygen Toxicity and Special Operations Forces Diving - Frontiers
    Exposure to a PO2 above 1.4 ATA can cause CNS toxicity, leading to a wide range of neurologic complaints including convulsions. Pulmonary oxygen toxicity ...Abstract · Central Nervous System Toxicity · Pulmonary Oxygen Toxicity · Summary
  24. [24]
    Understanding Oxygen Toxicity - Divers Alert Network
    Feb 1, 2013 · Symptoms of CNS oxygen toxicity, which include seizures, may occur after short exposures to partial pressures of oxygen greater than 1.3 ATA in ...Who Is Exposed To The Risk... · Oxidative And Nitrosative... · Effects Of Oxygen On The...<|separator|>
  25. [25]
    [PDF] NOAA CNS Percentage Exposure Table | ScubaBoard
    An exposure to a PO2 1.4 ATM is the maximum "recommended" limit for the working portion of any dive. Exposure levels above a PO2 of 1.4 ATM are shown for ...
  26. [26]
    Oxygen Exposure Management - InDEPTH Magazine
    Nov 2, 2021 · Today, community practices limit oxygen exposures to a PO2 of 1.2-1.4 bar for the working phase of the dive and 1.4-1.6 bar for decompression ...
  27. [27]
    Revised guideline for central nervous system oxygen toxicity ...
    Sep 30, 2025 · The (1991) limit for a single exposure to an inspire PO₂ of 1.3 atm is 180 min with a 24-hour maximum of 210 min. Recent studies provide ...
  28. [28]
    What is Oxygen Toxicity in Diving? Symptoms, Causes and Prevention
    Feb 2, 2023 · Carbon dioxide levels in the blood can affect your risk of CNS O2 toxicity. Exertion, dead space in breathing equipment and increased gas ...Pulmonary Oxygen Toxicity · Central Nervous System... · How to Prevent Oxygen...
  29. [29]
    Shearwater and the CNS Oxygen Clock
    Mar 23, 2015 · The table we use is from the NOAA Diving Manual (Fourth Edition):. This table can be read as “at a PPO2 of 1.0 ata, the maximum single exposure ...
  30. [30]
    Daily Limits for CNS Oxygen Toxicity - Doppler's Tech Diving Blog
    Feb 10, 2009 · The suggested working limit for this type of exposure is 80 percent of the maximum shown in the NOAA table. (e.g. 1.4 for 120 mins, 1.5 for 96 ...Missing: authoritative | Show results with:authoritative
  31. [31]
    [PDF] Oxygen Toxicity and Special Operations Forces Diving
    Jul 25, 2017 · In 1910 Bornstein was probably the first to expose two human volunteers in a dry dive setting to hyperbaric oxygen at a PO2 of 2.8 ATA (equal to ...
  32. [32]
    [PDF] The state of oxygen-enriched air (nitrox)
    The use of oxygen-enriched air (nitrox) has been a mainstream recreational diving mode since it was first introduced to sport divers in 1985 by former NOAA.
  33. [33]
    [PDF] The state of oxygen-enriched air (nitrox) - The Ocean Foundation
    The use of oxygen-enriched air (nitrox) has been a mainstream recreational diving mode since it was first introduced to sport divers in 1985 by former NOAA.
  34. [34]
    Maximum Operating Depth (MOD) and Scuba Diving - TripSavvy
    Sep 13, 2018 · A maximum operating depth (MOD) is a depth limit based on the percentage of oxygen in a diver's breathing gas.
  35. [35]
    None
    Below is a merged summary of the U.S. Navy Diving Manual (Rev 7) based on the provided segments. To retain all information in a dense and organized manner, I will use tables where appropriate to consolidate data on Maximum Operating Depth (MOD), Oxygen Partial Pressure Limits (PPO2), and Formulas for Calculating Depth. Narrative text will be used for additional details and URLs. The information is synthesized to avoid redundancy while preserving all unique details from the segments.
  36. [36]
    Max Depth (ENG) - CMAS
    Aug 15, 2025 · Max Operating Depth. Depending on diver training and experience, the maximum depth for diving depends on: a physiological limit linked to the ...
  37. [37]
    [PDF] Chapter 2 - Physics of Diving
    Thus, the specific gravity of seawater is. 64.0/62.4 = 1.026. 2.3 WATER ... calculating decompression tables. 2.8.5 General Gas Law. Pressure, volume ...
  38. [38]
    [PDF] Health Survey of U.S. Navy Divers from 1960 to 1990 - DTIC
    Furthermore, during this decade large-scale experimental manned diving studies were conducted to assess the effects of breathing elevated partial pressures of ...
  39. [39]
    Nitrogen Narcosis: What Divers Need To Know - PADI Blog
    Nov 18, 2022 · The easiest way to avoid getting narced is to limit your diving depth to 30m/98ft or shallower – especially if you're feeling tired or anxious.
  40. [40]
    [PDF] Maximum Operating Depth When Diving With Nitrox Based Upon ...
    Maximum Depth at. Contingency pO2 (1.6 ATA). 29. 126 ft (38 m). 149 ft (45 m). 30. 121 ft (37 m). 143 ft (43 m). 31. 116 ft (35 m). 137 ft (42 m).
  41. [41]
    [PDF] AquaCORPS | Edition 4 | 30th Anniversary Digial Re-Release
    B ottom Mix: TX 17/50. B ottom PO2: 1.46 ATM. DEPTH ... working depth of 250 fsw, using a trimix 17/50 ... MOD = (max PO2 -1) x 33. FO2. Example, the MOD of ...
  42. [42]
    Probing the limits of human deep diving - PubMed
    Substitution of oxygen-helium for compressed air has permitted divers to reach 600 m. However, at depths greater than 160 m, signs and symptoms of the high ...
  43. [43]
    V-Planner dive decompression planning software
    V-Planner calculates all types of Nitrox, Trimix, TriOx, HeliOx, OC, SCR, CCR, RB80, KISS and multilevel dives. V-Planner makes plans for Lost deco gas, Turn ...Missing: MOD | Show results with:MOD
  44. [44]
    [PDF] General Training Standards, Policies, and Procedures
    GUE's Technical Diver 2 course is designed to enhance deep diving proficiency while using helium breathing gases and oxygen-enriched decompression gases.
  45. [45]
    The Early Days of Technical Trimix Diving - InDEPTH Magazine
    The use of trimix—a breathing mix of oxygen, helium and nitrogen—has become the standard for dives beyond 30-50 m/100-165 ft, depending on whom you dive with.
  46. [46]
    Gas Switch Roulette - - SDI | TDI
    Depth- Are you at the correct switch depth? Dropping below the MOD increases your risk of a convulsion and alters your on/off-gassing in relation to your plan.
  47. [47]
    Thee Safety Protocols For Technical Diving - TDI SDI Asia
    Mar 25, 2020 · A protocol for validating gas switches to manage this risk is crucial. MODS provides this. While some divers attempt to rely on color coding, ...
  48. [48]
    CCR “Bailout”: Some Guidelines, a Few Thoughts and Planning for ...
    Jun 14, 2021 · For a CCR bailout, ensure enough gas for a safe ascent, with at least 80 cubic feet, and consider 60 cubic feet for sport dives, and more than ...
  49. [49]
    Decompression, Stage, and Bailout Cylinders - Divers Alert Network
    Jan 2, 2023 · Unlike stage cylinders, divers carry bailout cylinders throughout the dive to immediately access breathing gas if a rebreather failure occurs.
  50. [50]
    Equivalent Narcotic Depth (END) - SSI EMS
    CCR Diving/CCR Extended Range. Cover · Overview · What to Expect During ... Equivalent Narcotic Depth Calculation. END = [FN2 × (Depth + 10) / 0.79] - 10.
  51. [51]
    Equivalent Narcotic Depth (END) Calculator for Trimix and Heliox
    The Equivalent Narcotic Depth (END) for a given Trimix or Heliox mix and planned diving depth, is the depth of a dive when breathing air (i.e. FO2 = .21, O2% = ...
  52. [52]
    High-Pressure Neurological Syndrome - StatPearls - NCBI Bookshelf
    High-pressure neurological syndrome (HPNS) is a condition that occurs during deep-sea dives exceeding 150 meters and is characterized by neurological, ...Continuing Education Activity · Introduction · Pathophysiology · Evaluation
  53. [53]
    What is saturation diving? - DEEP - Engineering Wonder
    Oct 10, 2025 · How deep do saturation divers go? Commercial saturation diving operations typically take place between 100 and 300 meters. This is the range ...What Is Meant By Saturation... · What Is Decompression... · What Are Some Common Myths...
  54. [54]
    What is the maximum depth that can be reached with a normal ...
    Aug 9, 2024 · That is, SCUBA tanks are full at 3000 psi. When the water depth / pressure exceeds 3000 psi, the tank will no longer provide sufficient pressure ...What is the deepest a scuba tank can go? - QuoraWhat is the maximum depth for scuba diving without oxygen masks ...More results from www.quora.com
  55. [55]
    [PDF] is it time to abolish the 130 fsw depth limit? - New Jersey Scuba Diving
    Many recreational divers exceed the 130-foot limit, with 40% of computer users and 54% of workshop attendees exceeding it. Some even exceed 200 feet.