Fact-checked by Grok 2 weeks ago

Partition chromatography

Partition chromatography is a for separating mixtures of closely related chemical compounds based on their differential solubility, or partitioning, between two immiscible phases: a stationary phase immobilized on a solid support and a mobile phase that flows through it. Unlike adsorption chromatography, which relies on interactions with a , partition chromatography exploits the distribution of solutes governed by their partition coefficients, allowing for high-resolution separations of polar and nonpolar substances. The process operates on the principle of repeated extractions across many theoretical plates, where the height equivalent to a theoretical plate (H.E.T.P.) measures , typically achieving values around 0.002 cm in early setups. Developed in the early 1940s by British biochemists and Richard Laurence Millington Synge at the Wool Industries Research Association in , partition chromatography emerged from efforts to analyze in protein hydrolysates during wartime research on wool. Their seminal 1941 paper introduced the method using water-saturated as the stationary phase and with additives like n-butanol as the mobile phase, enabling the microdetermination of such as , , and with recoveries of 70–110%. For this innovation, which revolutionized analytical biochemistry, and Synge shared the 1952 . The technique built on Mikhail Tsvett's earlier adsorption chromatography () and countercurrent extraction principles, adapting them into a continuous column format for practical use. Initially applied in column form for , partition chromatography quickly evolved into by 1944, using to hold the stationary phase (water) and organic solvents as the mobile phase, which simplified qualitative separations of , sugars, and peptides. It laid the groundwork for modern variants like (TLC), high-performance liquid chromatography (HPLC), and gas-liquid chromatography (GC), proposed by Martin in 1941 and realized with Anthony T. James in 1952. Key applications include purifying biomolecules for structural elucidation—such as Frederick Sanger's insulin sequencing—and routine analyses in pharmaceuticals, , and , where it excels in separating isomers and heat-sensitive compounds. Today, while often integrated into automated systems, its core partitioning mechanism remains fundamental to liquid chromatography techniques worldwide.

Overview

Definition

Partition chromatography is a separation technique in which analytes are separated based on their differential partitioning between a stationary held on a solid support and a mobile that can be either a or a gas. This method relies on the distribution of solutes between the two immiscible phases, rather than adsorption onto a , allowing for separations driven by differences in . Invented by Archer J. P. Martin and Richard L. M. Synge in 1941, it marked a foundational advancement in chromatographic methods. The key components include the stationary phase, typically a liquid such as adsorbed onto a solid support like , which provides a thin film for partitioning without contributing to separation via adsorption. The mobile phase, exemplified by an organic solvent like containing a small amount of n-butanol, flows through the column and carries the analytes. In gas-liquid variants, the mobile phase is an , while the stationary phase remains a nonvolatile coated on an inert support, enabling separation of volatile compounds./Instrumentation_and_Analysis/Chromatography/V._Chromatography/D._Gas-Liquid_Chromatography) In the basic process, analytes introduced in the mobile phase dissolve and equilibrate between the two phases according to their relative solubilities, resulting in differential migration rates through the column. Components with higher affinity for the stationary phase spend more time retained, leading to retention times that are proportional to their partition coefficients and thus achieving separation as they elute at different times.

Core principles

Partition chromatography operates on the principle of partitioning, where solutes distribute between a stationary liquid phase and a mobile liquid phase based on their relative solubilities in each. The separation relies on the distribution ratio (D), defined as the ratio of the total amount of solute in the stationary phase to that in the mobile phase, such that components more soluble in the mobile phase elute faster than those preferring the stationary phase. This differential partitioning establishes an that drives the migration rates of analytes through the . The method requires two immiscible liquid phases to maintain distinct environments for ing, with the stationary phase typically coated onto an inert solid support, such as , to immobilize it and prevent mixing or flow during the passage of the mobile phase. This setup ensures that solutes repeatedly between the phases as the mobile phase flows, leading to selective retention based on differences. The retention factor (k), also known as the , quantifies the extent of solute interaction with the stationary phase and is defined as k = \frac{t_r - t_m}{t_m}, where t_r is the retention time of the solute and t_m is the time for an unretained to pass through the (equivalent to the ratio of time spent in the stationary phase to time in the mobile phase). Higher values of k indicate stronger retention, which affects peak positioning and overall separation efficiency. Resolution (R) between two solutes measures the effectiveness of separation and is influenced by k, with a basic form given by
R = \frac{\sqrt{N}}{4} (\alpha - 1) \frac{k}{1 + k},
where N is the number of theoretical plates (a measure of column efficiency), and α is the selectivity (ratio of retention factors of the two solutes). This equation highlights how optimal k values (neither too low nor too high) balance retention and elution speed to maximize R, though full derivations involving band broadening appear in discussions of separation dynamics.

History

Early development

Partition chromatography was invented in 1941 by biochemists Archer John Porter Martin and Richard Laurence Millington Synge at the Wool Industries Research Association in , , amid the early years of . Their work focused on developing analytical methods to determine the amino acid composition of wool proteins, a task critical to understanding materials and nutritional properties during wartime resource constraints. This innovation arose from combining principles of chromatography with countercurrent solvent extraction to achieve more efficient separations. Traditional adsorption chromatography, which relied on interactions between solutes and a solid stationary phase like , proved inadequate for separating polar compounds such as , as these often adsorbed too strongly, leading to incomplete or poor . and Synge addressed this by introducing a liquid-liquid , where separation depended on the distribution coefficients of solutes between two immiscible liquids rather than surface adsorption. This approach allowed for the handling of small sample quantities ( scale) and provided quantitative recovery, overcoming the limitations of prior techniques. Their seminal work included two papers in the Biochemical Journal (December 1941): one outlining the theoretical principles of (Part 1) and the other detailing the application to the micro-determination of higher monoamino-acids in proteins (Part 2). The initial experimental setup involved a vertical column packed with particles that held water as the stationary phase, saturated by the descending organic mobile phase. Martin and Synge's first on the method appeared in the Biochemical Journal in December 1941, detailing the separation of higher monoamino acids from hydrolysates using water-saturated -chloroform (approximately 0.5% in ) as the mobile phase. This column-based system marked the foundational shift to partition , enabling precise micro-analysis of complex mixtures. Their contributions were recognized with the 1952 .

Key milestones and recognition

In 1944, Archer J.P. Martin, along with R. Consden and A.H. , extended the partition chromatography method to paper-based systems, where served as a solid support impregnated with a stationary liquid phase, enabling the separation of and other biomolecules through liquid-liquid partitioning. This adaptation simplified the technique and broadened its accessibility for qualitative and quantitative analyses in biochemical research. During the 1950s, the development of gas-liquid partition chromatography (GLPC) by A.T. James and A.J.P. Martin marked a significant advancement, allowing the efficient separation and micro-estimation of volatile compounds such as fatty acids by using an as the and a coated on a solid support. This innovation, first detailed in 1952, overcame limitations of liquid-liquid systems for non-volatile or thermally unstable analytes and laid the groundwork for modern . The profound impact of partition chromatography was recognized in when Archer J.P. Martin and Richard L.M. Synge were awarded the "for their invention of partition chromatography," honoring their pioneering work that revolutionized separation science. In the and , partition chromatography influenced the emergence of (HPLC), particularly through precursors like column liquid-liquid partitioning and the introduction of reversed-phase adaptations, where non-polar stationary phases enhanced selectivity for a wide range of organic compounds. These developments improved resolution and speed, transitioning partition principles into high-pressure systems that became staples in analytical laboratories. Post-2000, partition chromatography has been consistently acknowledged in textbooks as a foundational underpinning modern chromatographic methods, with its principles of solute distribution between immiscible phases remaining central to and . For instance, standard references highlight its role in the evolution of HPLC and , emphasizing its enduring legacy in separation science.

Theoretical basis

Partition coefficient

The partition coefficient, denoted as K, is the fundamental quantitative measure in partition chromatography, defined as the of the equilibrium concentration of a solute in the stationary phase to its concentration in the mobile phase:
K = \frac{[\text{solute}]_{\text{stationary}}}{[\text{solute}]_{\text{mobile}}}
This parameter captures the solute's preferential distribution between the two immiscible liquid phases, underpinning the separation mechanism. In contexts emphasizing hydrophobicity, such as octanol-water systems, it is often expressed as \log P, providing a scale for that correlates with biological and environmental behaviors.
The is determined experimentally through methods like the shake-flask technique, where a solute is equilibrated between measured volumes of the two phases, followed by analytical quantification (e.g., via or ) of concentrations in each phase to compute K. Alternatively, in chromatographic setups, K is derived from retention data: the retention factor k (dimensionless measure of retention) relates to K via the phase volume ratio \beta = V_s / V_m, where V_s and V_m are the and phase volumes, respectively. Specifically, for solutes, k = K \beta, allowing K = k / \beta to be calculated from observed retention times t_R using k = (t_R - t_0)/t_0, with t_0 as the void time. This chromatographic approach is particularly useful for direct assessment under separation conditions. Several factors influence the value of K. Temperature affects partitioning through the van't Hoff equation, which describes the thermodynamic basis:
\ln K = -\frac{\Delta H^\circ}{RT} + \frac{\Delta S^\circ}{R}
where \Delta H^\circ and \Delta S^\circ are the standard enthalpy and entropy of transfer, R is the gas constant, and T is the absolute temperature; plotting \ln K versus $1/T yields a straight line for enthalpy-driven processes, with typical \Delta H^\circ values indicating exothermic solvation in polar phases. For ionizable compounds, pH modulates partitioning by altering the protonation state, reducing partitioning into nonpolar stationary phases when charged; the apparent distribution coefficient D (total solute concentration ratio, stationary to mobile) is thus pH-dependent, often lower at pH extremes for acids or bases. Solvent polarity also governs K, as greater differences in phase polarities enhance distribution contrasts for solutes with intermediate solubility.
The retention factor k relates to the distribution coefficient D via k = D \beta, where \beta = V_s / V_m is the stationary-to-mobile phase volume ratio and D accounts for total (neutral + ionized) solute distribution between phases. For solutes, D = K, so k = K \beta, linking the microscopic partitioning equilibrium to macroscopic retention behavior; k remains constant across conditions for solutes, reflecting pure solubility-driven equilibrium. In contrast, for charged solutes like a weak (e.g., , pK_a ≈ 4.2), at low pH (protonated, form) D \approx K (e.g., K ≈ 74 for octanol-water, log K ≈ 1.87), yielding higher k \approx K \beta (with typical β ≈ 0.2–0.5 in liquid chromatography, k ≈ 15–37), favoring stationary phase retention, while at high pH (deprotonated, anionic), D drops significantly (e.g., by 2–4 orders of magnitude, as the fraction f_neutral ≈ 10^{pK_a - pH}) due to poor partitioning of the , reducing k and often requiring pH adjustment for optimal separation. This pH dependence highlights how scales the inherent K to predict behavior in ionizable solutes. The partition coefficient's magnitude directly impacts retention: higher K values prolong solute residence in the stationary phase, increasing t_R and enabling isolation of hydrophobic compounds. Selectivity \alpha between two solutes, critical for resolution, is quantified as \alpha = K_2 / K_1 (assuming similar diffusion properties), where differences in K (e.g., \alpha > 1.5) drive effective separations in applications like amino acid analysis.

Separation dynamics

In partition chromatography, separation occurs through an equilibrium process where solutes repeatedly partition between the mobile and stationary liquid phases as the mobile phase flows through the column. During each partitioning event, a fraction of the solute distributes into the stationary phase based on its , leading to differential rates among analytes. The of a solute is given by v_{\text{net}} = \frac{u}{1 + k}, where u is the linear of the mobile phase and k is the retention factor, reflecting the average time spent in each phase. This repeated equilibration results in band formation, with more retained solutes eluting later due to slower advancement. Band broadening in partition chromatography arises from multiple dispersion mechanisms, including eddy diffusion (A term), longitudinal diffusion (B term), and mass transfer resistance (C term), as described by the van Deemter equation: H = A + \frac{B}{u} + C u, where H is the height equivalent to a theoretical plate. In liquid-liquid systems, the C term often dominates because of slow solute diffusion across the liquid-liquid interface and within the viscous stationary phase, leading to non-equilibrium conditions during flow and increased peak widths. Eddy diffusion stems from uneven flow paths around support particles, while longitudinal diffusion contributes more at low velocities but is minimized in liquids compared to gases. Resolution in partition chromatography quantifies the separability of two adjacent peaks and is derived from as R = \frac{\sqrt{N}}{4} (\alpha - 1) \frac{k}{1 + k}, where N is the number of theoretical plates, \alpha is the selectivity factor (ratio of retention factors), and k is the average retention factor. The number of theoretical plates is calculated as N = \frac{L}{H}, with L as column length, or equivalently from peak statistics as N = \left( \frac{t_R}{\sigma} \right)^2, where t_R is retention time and \sigma is the standard deviation of the Gaussian . This formulation shows that resolution improves with higher (N), greater selectivity (\alpha > 1), and optimal retention (k \approx 2-10); partition chromatography excels here for structurally similar compounds, as small differences in partition coefficients yield reliable \alpha values, unlike adsorption methods prone to abrupt retention changes. A key limitation of classical partition chromatography is the slow kinetics in viscous liquid stationary phases, which exacerbates the C term in the and reduces efficiency at higher flow rates. This arises from the finite time required for solute equilibration across the , particularly when using high-viscosity solvents. Modern variants mitigate this by employing thinner films or dynamic coatings to enhance interfacial area and reduce diffusion path lengths.

Techniques and variants

Liquid-liquid methods

Liquid-liquid partition chromatography employs two immiscible liquid phases, with one serving as the stationary phase retained on a solid support and the other as the mobile phase that flows through the system, allowing solutes to partition based on their relative solubilities. The foundational technique was developed by Archer J.P. Martin and Richard L.M. Synge in 1941, who utilized a column packed with impregnated with water as the stationary phase and a chloroform-butanol as the mobile phase to separate , achieving resolutions that demonstrated the feasibility of liquid-liquid partitioning for analytical separations. This setup addressed limitations of earlier adsorption methods by enabling reversible solute distribution without irreversible binding. A key variant, , was introduced in 1944 by Richard Consden, A.H. Gordon, and as a simple, planar form of liquid-liquid partition chromatography. In this method, acts as the solid support impregnated with a stationary liquid, typically water adsorbed onto the cellulose fibers, while a polar solvent serves as the ascending or descending mobile phase, carrying the sample components along the paper strip. Separation occurs as solutes partition between the aqueous stationary phase and the mobile phase, with the retention factor (Rf) quantifying the extent of migration, defined as: R_f = \frac{\text{distance traveled by solute}}{\text{distance traveled by solvent front}} This value, ranging from 0 to 1, provides a reproducible measure of solute behavior under specific conditions and facilitated early qualitative analyses of complex mixtures like protein hydrolysates. Paper chromatography's accessibility made it widely adopted for educational and preliminary separations before more advanced instrumentation. Column-based liquid-liquid chromatography evolved from the 1941 prototype, with modern implementations including droplet countercurrent chromatography (DCCC), a support-free technique introduced in 1970 by T. Tanimura, J.J. Pisano, Y. Ito, and R.L. Bowman. DCCC uses long, coiled polytetrafluoroethylene tubes filled with the stationary liquid phase, through which droplets of the mobile phase flow under gravity, enabling efficient partitioning without solid support interference. Developments in the late 1970s and 1980s expanded DCCC's utility, such as Kurt Hostettmann's 1980 application for preparative isolation of glycosides from plant extracts, highlighting its role in natural product purification with resolutions comparable to gas chromatography for milligram quantities. For preparative-scale separations, large-diameter columns (up to several centimeters) accommodate gram-scale loadings, as demonstrated in early extensions of and Synge's work and later countercurrent variants. Phase system selection is critical, with biphasic mixtures like hexane-ethyl acetate-methanol-water (commonly adjusted to form equal-volume layers) providing tunable for diverse analytes. These systems support high-throughput purification, such as isolating chiral compounds or metabolites at yields exceeding 90% for targeted fractions. Liquid-liquid methods offer advantages including high loading capacity for polar analytes, owing to the use of aqueous or highly polar phases that enhance and minimize denaturation risks compared to supports. However, a notable disadvantage is phase bleeding, where the liquid gradually dissolves into the mobile phase over repeated runs, reducing efficiency and necessitating frequent re-equilibration.

Gas-liquid methods

Gas-liquid partition chromatography, a pivotal variant of partition chromatography, was introduced in 1952 by A. T. James and A. J. P. Martin at the in . This method utilized an inert carrier gas, initially , to transport vaporized analytes through a column packed with a solid support coated with a non-volatile liquid stationary phase, such as paraffin oil on firebrick particles. The technique enabled rapid separation of volatile compounds, particularly fatty acids, by leveraging differences in their partitioning between the gaseous mobile phase and the liquid film. In this setup, analytes are injected in vapor form and carried by the gas stream, where they equilibrate between the mobile phase and the thin liquid layer adsorbed on the support. The retention volume V_R, defined as the volume of carrier gas required to elute the analyte to its peak maximum, is given by V_R = V_m (1 + k), where V_m is the void volume of the column (mobile phase volume) and k is the retention factor representing the distribution ratio between stationary and mobile phases. This equation underscores the direct influence of partitioning on separation efficiency, with higher k values indicating stronger retention in the liquid phase. Precise control of column via an is essential to maintain and optimize separation, as affects and partition coefficients. Early implementations operated isothermally at constant temperatures, suitable for analytes with similar boiling points, but this limited for mixtures spanning wide ranges. programming, involving gradual heating (typically 2–20 °C/min), was later adopted to sharpen peaks of higher-boiling components and enhance overall efficiency. Detection in early gas-liquid systems relied on thermal conductivity detectors (TCD), which measured differences in the thermal conductivity of the carrier gas altered by eluted analytes, providing universal response but limited for trace levels. Modern applications favor ionization detectors (FID) for compounds, offering high (down to picograms) through in a hydrogen-air , though they are destructive and carbon-specific. In the , hyphenation with (GC-MS) has revolutionized trace analysis, combining chromatographic separation with structural identification for complex mixtures at parts-per-billion levels.

Applications

Biochemical separations

Partition chromatography has played a pivotal role in the separation of and peptides since its inception, with and Synge demonstrating in their 1941 paper the effective separation of higher monoamino-acids from protein hydrolysates, including , using a column-based partition chromatography with water-saturated as the stationary phase and containing n-butanol as the mobile phase. This resolved components based on their differential partitioning between the two phases. The laid the groundwork for subsequent adaptations, including the use of the n-butanol-acetic acid-water (4:1:5) system in early column and paper-based partition chromatography, which enabled the clear resolution of up to 18 by the mid-1940s through their partitioning between the aqueous stationary phase and the organic mobile phase on silica or paper supports. In the purification of proteins and enzymes, aqueous two-phase systems (ATPS) represent a key application of partition principles, where biomolecules distribute between immiscible polymer-rich phases such as (PEG) and , facilitating large-scale separations under mild conditions that preserve . For instance, ATPS using PEG-dextran has been optimized for recovering enzymes like from calf intestine, achieving high yields through selective partitioning influenced by factors such as pH, salt concentration, and polymer molecular weight. This approach, originally developed in the late 1950s, continues to be refined for industrial-scale , offering scalability and superior to many other methods. Early applications extended to nucleotides and carbohydrates in the 1950s, with paper partition chromatography proving instrumental in separating sugar mixtures from natural sources using solvent systems like ethyl acetate-acetic acid-water or butanol-based mixtures, allowing identification and quantification of components such as glucose, fructose, and maltose through their Rf values. Similarly, paper chromatography resolved purine and pyrimidine nucleotides, as demonstrated by Chargaff's work analyzing DNA base compositions, where two-dimensional development separated adenine, guanine, cytosine, and thymine based on partitioning behavior. These techniques provided essential tools for elucidating carbohydrate structures and nucleic acid compositions during a formative era in biochemistry. In modern bioanalytical contexts, partition chromatography integrates with two-dimensional electrophoresis in hybrid workflows for , where initial liquid-liquid partitioning prefractionates complex protein mixtures prior to gel-based separation, enhancing of low-abundance species in mapping. Recent advancements in the 2020s have further leveraged partition-based hydrophilic interaction liquid chromatography (HILIC) for , effectively separating polar metabolites like , sugars, and acids in biological samples, with methods achieving comprehensive coverage of over 100 polar compounds via optimized gradients and phases that promote water-layer partitioning. These applications partition chromatography's enduring in biochemical research, with extensions to pharmaceutical metabolite profiling for .

Industrial and analytical uses

In the pharmaceutical industry, partition chromatography plays a crucial role in quality control processes, particularly through reversed-phase high-performance liquid chromatography (RP-HPLC) using C18 stationary phases to assess the purity of active pharmaceutical ingredients (APIs). This method separates drug compounds based on their hydrophobicity, enabling the detection of impurities at trace levels to ensure compliance with regulatory standards such as those set by the FDA and EMA. For instance, RP-HPLC with C18 columns is routinely employed to quantify APIs like cetrorelix acetate, providing high-resolution separations that support batch release and stability testing. Food and environmental analysis heavily relies on gas-liquid partition chromatography, especially gas chromatography (GC) coupled with (GC-MS), for separating and quantifying and fatty acids in edible oils. In assessments, GC methods effectively profile residues in oils, achieving detection limits below regulatory thresholds like those of the EU's maximum residue limits (MRLs), thus preventing contamination risks in consumer products. Similarly, for , GC separates short- and long-chain fatty acids in oils to evaluate impacts, such as lipid alterations from industrial effluents. These applications highlight GC's versatility in handling volatile analytes without derivatization for non-polar compounds. Forensic applications of partition chromatography include metabolite profiling in , where GC-MS serves as a primary tool for identifying and quantifying metabolites in biological samples like blood and urine. This technique separates volatile drug derivatives based on partition coefficients, enabling the reconstruction of exposure timelines for substances such as opioids and amphetamines, with sensitivity down to ng/mL levels critical for legal determinations. In casework, GC-MS confirms metabolite patterns, such as those from , supporting overdose investigations and impaired driving analyses. Recent advancements as of 2025 emphasize green partition methods incorporating ionic liquids (ILs) to enhance across these applications. ILs, such as imidazolium-based variants, act as eco-friendly mobile additives or modifiers in RP-HPLC and liquid-liquid extractions, reducing volatile use by up to 80% while maintaining separation for pharmaceuticals and environmental analytes. These developments, including biodegradable ILs for liquid-liquid processes, address environmental concerns by lowering toxicity and waste, aligning with green principles for industrial scalability.

Comparisons and distinctions

Versus adsorption chromatography

Partition chromatography and adsorption chromatography differ fundamentally in their separation mechanisms. In , separation occurs through the reversible dissolution of between a immobilized on a solid support and a , governed by differences in and the K = \frac{[A]_s}{[A]_m}, where [A]_s and [A]_m are the concentrations of analyte A in the stationary and mobile phases, respectively. In contrast, adsorption chromatography involves the physical binding of analytes to the active surface sites of a solid stationary phase, such as silica gel's groups (Si–OH) or alumina's polar surfaces, via interactions like hydrogen bonding, van der Waals forces, or dipole-dipole attractions, leading to surface adsorption rather than dissolution. The selectivity profiles of the two methods also diverge significantly. Partition chromatography excels at separating compounds with similar polarities by leveraging small differences in partition coefficients, enabling high-resolution separations for closely related molecules without strong peak tailing, as the liquid phases provide uniform solvation environments. Adsorption chromatography, however, is more effective for mixtures spanning broad polarity ranges, where selectivity arises from varying affinities of functional groups for the heterogeneous active sites on the (e.g., mono-, di-, or trisilanols on silica), though this often results in asymmetric peaks and reduced efficiency for polar analytes. The role of the solid support further underscores these distinctions. In partition chromatography, the solid support (e.g., or silica) serves solely as an inert carrier to hold the liquid stationary phase, with no direct participation in analyte interactions, ensuring the separation is purely liquid-liquid. In adsorption chromatography, the solid support itself—such as polar silica or alumina—is the active stationary phase, where analytes bind directly to its surface functional groups, making the support's chemical properties central to the separation process. Historically, the development of partition chromatography in the 1940s by Archer J.P. Martin and Richard L.M. Synge addressed key shortcomings of adsorption methods, particularly their poor resolution and peak tailing for polar compounds like , which bound irreversibly or unevenly to solid adsorbents; their liquid-liquid approach enabled precise separations of such biomolecules, earning them the 1952 . A representative example illustrates these differences: , a moderately polar , can be separated via partition chromatography using a water- biphasic system, where it preferentially partitions into the organic phase (with a K \approx 9 for chloroform-water), yielding efficient based on ./2:Lab_Textbook(Nichols)/04:_Extraction/4.05:_Extraction_Theory) In adsorption chromatography, binds to the polar surface of alumina via hydrogen bonding with its hydroxyl groups, allowing separation from less polar impurities but often requiring careful to avoid tailing.

Versus ion-exchange chromatography

Partition chromatography operates on the principle of differential partitioning of analytes between two immiscible liquid phases—a stationary liquid phase coated on a solid support and a mobile phase—driven by differences, making it particularly effective for or uncharged such as compounds. In contrast, ion-exchange chromatography relies on electrostatic interactions between charged analytes and oppositely charged functional groups fixed on a solid resin matrix, such as sulfonate groups in cation exchangers or ammonium groups in anion exchangers, which selectively bind ions or charged biomolecules like proteins based on their net charge. This fundamental distinction—solubility-based partitioning without reliance on charge versus charge-specific ionic binding—defines their separation mechanisms, as originally conceptualized in partition chromatography by Martin and Synge in their seminal work on separations. Regarding applicability, partition chromatography excels in separating non-ionic molecules, including hydrocarbons, steroids, and small organics, where charge does not play a role, whereas ion-exchange is preferentially used for ionic species such as metal salts, , and proteins adjusted to specific values to control their state. For instance, partition methods are commonly applied to neutral lipids, while ion-exchange targets charged peptides at pH below or above their isoelectric points. Capacity in partition chromatography is proportional to the volume of the stationary liquid phase, allowing scalability through phase ratio adjustments, in opposition to ion-exchange, where binding is constrained by the density of charged sites on the but enables repeated use via regeneration with salt eluents or pH shifts. Resolution in partition chromatography is achieved by tuning the retention factor (k) through modifications to the mobile or stationary phase solvents, exploiting differences in analyte polarity and solubility. Ion-exchange resolution, however, is modulated primarily via ionic strength gradients or pH changes that alter analyte-resin electrostatic affinities, providing high selectivity for closely related charged species. Post-2000 developments in mixed-mode chromatography have integrated these principles, with stationary phases combining reversed-phase partitioning (a variant of partition chromatography) and ion-exchange sites to enhance separation of complex mixtures containing both neutral and charged analytes, such as pharmaceuticals and their counterions, offering improved selectivity over single-mode approaches.

Modern advances

Reversed-phase adaptations

Reversed-phase partition chromatography emerged in the 1950s as a pivotal , inverting the of the classical - setup by employing a non-polar stationary phase and a polar mobile phase. Introduced by G.A. Howard and A.J.P. Martin in their 1950 study on separating C12-C18 fatty acids, the technique utilized a non-polar stationary phase, such as hydrocarbons or silicones impregnated on a solid support like kieselguhr, with an aqueous alcoholic mobile phase to achieve effective partitioning based on hydrophobicity. Over time, this evolved to include bonded non-polar phases, such as octanol-coated supports or alkyl chains (e.g., C18) chemically attached to silica particles, paired with polar mobile phases like water-acetonitrile mixtures, enhancing versatility for diverse analytes. The underlying mechanism centers on hydrophobic interactions, where analytes preferentially partition into the non-polar stationary phase from the polar mobile phase according to their , leading to retention that scales with molecular hydrophobicity. This partitioning behavior shows a strong linear with the (log P), enabling predictive modeling of retention times and facilitating quantitative structure-retention relationships in method development. In (HPLC), reversed-phase adaptations gained prominence in the 1970s through the widespread adoption of C18-bonded silica columns with 5-μm particles, which delivered superior efficiency and resolution for routine separations of organic compounds. These bonded phases provided key advantages over classical liquid-liquid systems, including enhanced chemical and mechanical stability without stationary phase bleeding or dissolution, and broad applicability to non-polar and moderately polar organics across pharmaceuticals, environmental samples, and natural products. Advancements into the 2020s have further refined reversed-phase techniques via ultra-high-performance liquid chromatography (UHPLC), incorporating sub-2-μm particles in C18 columns to achieve faster analysis times—often reducing run lengths by factors of 3–5—while preserving high plate counts exceeding 100,000 per meter for complex mixtures.

Integration with contemporary technologies

Partition chromatography has been integrated with mass spectrometry through hyphenated techniques such as gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS), enabling precise identification of analytes separated via partition mechanisms. In GC-MS, volatile compounds partition between a gaseous mobile phase and a stationary phase coated on a solid support, with providing structural elucidation for complex mixtures in environmental and pharmaceutical analyses. Similarly, LC-MS employs liquid-liquid partition columns, often in reversed-phase configurations, where (ESI) facilitates the detection of polar analytes by ionizing them in the liquid mobile phase without excessive fragmentation. These integrations, developed prominently since the 1980s, enhance sensitivity and specificity, allowing trace-level detection in and . Advancements in have incorporated principles into chip-based systems for , particularly since the early 2000s. These microscale devices miniaturize liquid-liquid chromatography, where analytes distribute between immiscible liquid phases within etched channels, enabling rapid separations of biomolecules like proteins and nucleic acids with minimal sample volumes. By leveraging and droplet encapsulation, such systems enable supporting and studies. This integration reduces reagent consumption and accelerates iterative testing compared to traditional macroscale setups. Automation in partition chromatography is exemplified by simulated moving bed (SMB) systems, which enable continuous production for preparative-scale separations, including chiral resolutions. In SMB, multiple columns simulate a countercurrent flow of liquid phases, optimizing partition equilibria to achieve high purity and yield in pharmaceutical manufacturing. Widely adopted for enantiomer separations since the 1990s, these automated setups process kilograms of material per day, minimizing downtime and solvent use through cyclic valve switching. Supercritical fluid chromatography (SFC) represents a green chemistry adaptation of partition principles, utilizing supercritical CO2 as the primary mobile phase to reduce organic solvent consumption by up to 90% compared to conventional liquid chromatography. In SFC, analytes partition between the stationary phase and the CO2-based fluid, often modified with co-solvents, enabling efficient separations of chiral and lipophilic compounds with lower environmental impact. This hybrid approach, refined in the 2000s, supports sustainable industrial processes by recycling CO2 and minimizing waste generation. Recent integrations leverage (AI) for optimizing selection in partition chromatography method development, with notable progress by 2025. AI algorithms, employing quantitative structure-retention (QSRR) models, predict optimal and combinations to enhance separation , reducing experimental iterations from weeks to hours. Machine learning-driven tools analyze vast datasets to select partition-compatible phases for complex samples, improving in high-throughput LC applications. These AI advancements, integrated into software platforms, address challenges in polar analyte partitioning and facilitate greener method design.

References

  1. [1]
    [PDF] Archer J. P. Martin - Nobel Lecture
    The subject of partition chromatography has now an extensive literature and. I feel on an occasion such as this it is better to describe the development of.
  2. [2]
    Partition Chromatography - an overview | ScienceDirect Topics
    Partition chromatography was introduced by Martin and Synge in 1941 for the separation of acetylated amino acids and was first applied to the separation of ...
  3. [3]
    Chromatography - StatPearls - NCBI Bookshelf
    Jan 11, 2024 · Chromatography is a commonly used technique in clinical laboratories for diagnosing inborn carbohydrate, protein, and lipid metabolism errors.Missing: history | Show results with:history
  4. [4]
  5. [5]
    Chromatographic-Based Platforms as New Avenues for Scientific ...
    Aug 18, 2022 · Chromatography was born approximately one century ago and has undergone outstanding technological improvements in innovation, research, ...
  6. [6]
    [PDF] 〈621〉CHROMATOGRAPHY - US Pharmacopeia (USP)
    Retention factor (k): The retention factor (also known as mass distribution ratio (D ) or capacity factor. (k′)) is defined as: K. = distribution constant ...
  7. [7]
  8. [8]
    Chromatography - NJIT
    From this equation the interaction of the three factors which influence resolution can be seen. A low value of k' for the compounds being separated will lower ...Missing: distribution | Show results with:distribution
  9. [9]
    A new form of chromatogram employing two liquid phases - NIH
    A new form of chromatogram employing two liquid phases: A theory of chromatography. 2. Application to the micro-determination of the higher monoamino-acids in ...
  10. [10]
    Journey Through the History of Paper Chromatography - Chrom Tech
    Nov 20, 2024 · The 1944 publication in the Biochemical Journal by Archer Martin and Richard Synge detailing their work on paper chromatography for ...
  11. [11]
    the separation and micro-estimation of volatile fatty acids ... - PubMed
    Gas-liquid partition chromatography; the separation and micro-estimation of volatile fatty acids from formic acid to dodecanoic acid. Biochem J. 1952 Mar;50 ...
  12. [12]
    Gas-liquid partition chromatography. A technique for the analysis of ...
    Gas-liquid partition chromatography. A technique for the analysis of volatile materials. A. T. James and A. J. P. Martin, Analyst, 1952, 77, 915 DOI: 10.1039/ ...Missing: 1950s | Show results with:1950s
  13. [13]
    The Nobel Prize in Chemistry 1952 - NobelPrize.org
    The Nobel Prize in Chemistry 1952 was awarded jointly to Archer John Porter Martin and Richard Laurence Millington Synge for their invention of partition ...
  14. [14]
    Reaching New Horizons in Reversed-Phase Chromatography ...
    For decades, reversed-phase (RP) chromatography has dominated HPLC applications. Almost as soon as bonded reversed phases became available in the early 1970s, ...
  15. [15]
    [PDF] Milestones in the development of liquid chromatography
    The development of HPLC depended on new columns, which in turn required new particles, new stationary phases (particle coatings), and improved procedures for.
  16. [16]
    Fundamentals of Analytical Chemistry - Douglas A. Skoog
    Jun 6, 2022 · FUNDAMENTALS OF ANALYTICAL CHEMISTRY, EIGHTH EDITION is known for its readability combined with a systematic, rigorous approach that ...
  17. [17]
    Experimental Determination of Octanol–Water Partition Coefficients ...
    Feb 25, 2020 · The miniaturized shake-flask approach allowed reliable quantification of pH-dependent partitioning behavior for neutral, acidic, and basic ...Introduction · Materials and Methods · Results and Discussion · Conclusions
  18. [18]
    Using Thermodynamics and Simulations to Understand Selectivity ...
    Feb 1, 2023 · Equation 3 is the classical van 't Hoff equation, which relates the partition coefficient to the standard enthalpy and entropy of a reaction. ...
  19. [19]
    pH-Dependent Partitioning of Ionizable Organic Chemicals between ...
    The pH-dependent partitioning of 190 organics and IOCs covering a range of octanol–water partition constants log K ow from −0.3 to 7.7 was evaluated with a 10- ...
  20. [20]
    Longitudinal diffusion and resistance to mass transfer as causes of ...
    Longitudinal diffusion and resistance to mass transfer as causes of nonideality in chromatography. Author links open overlay panel J.J. van Deemter 1 , ... View ...
  21. [21]
    Chapter 8 Liquid—liquid (partition) chromatography - ScienceDirect
    Liquid-liquid partition chromatography involves distributing a sample between two immiscible solvents, with one on a support and the other as a mobile phase.
  22. [22]
    Partition Chromatography - an overview | ScienceDirect Topics
    Partition chromatography involves separating a solute between two immiscible liquids, one stationary on a solid support, based on its distribution coefficient.Missing: foundational post-
  23. [23]
    History of gas chromatography - ScienceDirect
    Modern gas chromatography (GC) was invented by Martin and James in 1952 [1] ... The carrier gas, at first nitrogen, but now helium or hydrogen, passes ...
  24. [24]
    GC-MS Principle, Instrument and Analyses and GC-MS/MS
    Feb 16, 2024 · Gas chromatography mass spectrometry (GC-MS) consists of two very different analytical techniques: gas chromatography (GC) which is hyphenated ( ...
  25. [25]
    Separation of the higher monoamino-acids by counter-current liquid ...
    Separation of the higher monoamino-acids by counter-current liquid-liquid extraction: the amino-acid composition of wool. Biochem J. 1941 Jan;35(1-2):91-121.Missing: partition chromatography butanol- acetic
  26. [26]
    Paper chromatography of amino acids and other organic ...
    RF values of selected compounds in ethanol-acetic acid, butanol-ethanol-water, butanol-acetic acid-water, and ethanol are given. The production of ...
  27. [27]
    Detecting Proteins Separated by 2-D Gel Electrophoresis.
    A guide to choosing the right stain, dye, and fluorescent or radioactive label.
  28. [28]
    Aqueous two-phase system (ATPS): an overview and advances in ...
    Oct 28, 2016 · ATPS is a liquid-liquid fractionation technique and has gained an interest because of great potential for the extraction, separation, purification and ...
  29. [29]
    An improved purification procedure of alkaline phosphatase from ...
    Aqueous two-phase partitioning has been elaborated in order to improve the purification of alkaline phosphatase from calf intestine in larger scale.
  30. [30]
    Advancements in Aqueous Two-Phase Systems for Enzyme ...
    This review deals with the principles, applications, and advantages of aqueous two-phase systems (ATPS) as an alternative to conventional LLE.
  31. [31]
    Chromatographic separations as a prelude to two-dimensional ...
    Current methods of proteome analysis rely almost solely on two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) followed by the excision of individual ...
  32. [32]
    Two-dimensional gel electrophoresis in proteomics: A tutorial
    Sep 6, 2011 · The purpose of this tutorial paper is to guide the reader through the history of the field, then through the main steps of the process.
  33. [33]
    New analytical methods focusing on polar metabolite analysis in ...
    Here, we review developments in LC-MS, GC–MS and NMR methods in the last few years that have enhanced quantitative and comprehensive metabolome coverage.
  34. [34]
    Development and Validation of a Reversed-phase HPLC Method for ...
    A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with ...<|separator|>
  35. [35]
    Reverse Phase High-performance Liquid Chromatography
    For improved retention and selectivity, polar drug analysis usually uses C18 columns, pH-controlled buffers, and aqueous-rich mobile phases. In contrast, ...
  36. [36]
    Determination of 229 pesticides residue in edible oil samples using ...
    May 24, 2025 · The pesticides were analyzed by an Agilent gas chromatograph 7890B series that was coupled with an Agilent mass spectrometer model 5977 A and ...
  37. [37]
    Application of gas chromatography in food analysis - ScienceDirect
    Without chemical derivatization, GC is often used for the analysis of sterols, oils, low chain fatty acids, aroma components and off-flavors, and many ...
  38. [38]
  39. [39]
    The Use of Gas Chromatography to Analyze Compositional ... - NIH
    Mar 13, 2014 · Gas chromatography (GC) is a well-established technique used to identify and quantify the incorporation of fatty acids into lipid pools and cell ...<|separator|>
  40. [40]
    Simulated Moving Bed Chromatography - Orochem Technologies
    Simulated moving bed (SMB) technology is a chromatography technique that is traditionally used in oil and energy industry for recovery and purification of p- ...Missing: partition petroleum fractionation
  41. [41]
    Unleashing the Power of Simulated Moving Bed Chromatography
    The integration of Simulated Moving Bed Chromatography into the petrochemical industry marks a significant step forward in refining processes.Missing: hydrocarbon | Show results with:hydrocarbon
  42. [42]
    Simulated moving bed processing: escape from the high-cost box
    The resulting cost savings made many chromatographic separations economically feasible; major commodity applications are found in the petroleum industry 8, 9, ...Missing: hydrocarbon | Show results with:hydrocarbon
  43. [43]
    Mass Spectrometry Applications for Toxicology - PMC
    MS has become a powerful analytical technique with a wide range of application used in the Toxicological analysis of drugs, poisons, and metabolites of both.
  44. [44]
  45. [45]
    Chromatography and Forensics - News-Medical.Net
    Jan 11, 2021 · In forensic investigations, gas chromatography is used in toxicology screening to determine if a deceased person has ingested drugs or alcohol ...Use In Forensics · Coupling Chromatography With... · SourcesMissing: partition | Show results with:partition<|control11|><|separator|>
  46. [46]
    What is Gas Chromatography Used for in Forensic Science? - MONAD
    Jun 21, 2024 · Gas chromatography is used in forensic science for drug analysis, toxicology, arson, explosives, and identifying unknown substances.Drug Analysis · Toxicology · Arson Investigation
  47. [47]
    Green Approaches in High-Performance Liquid Chromatography for ...
    This review provides a comprehensive overview of the recent green innovations in high-performance liquid chromatography (HPLC) for sustainable food analysis ...
  48. [48]
    Green solvents and their role in modern sample preparation for ...
    Oct 27, 2025 · Research indicates that ionic liquids enhance the extraction efficiency of target analytes while minimizing the solvent volume required during ...
  49. [49]
    Synthesis and applications of ionic liquids for chromatographic ...
    Jan 4, 2025 · The review provides sound scientific data to examine the structural characteristics of ionic liquids that make them ideal for use in chromatography.Missing: partition | Show results with:partition
  50. [50]
    Exploring Ionic Liquid-Based Liquid–Liquid Extraction as a Benign ...
    Jan 29, 2025 · This advancement is crucial for guaranteeing the long-term sustainability and economic feasi- bility of IL-based LLE in industrial applications.
  51. [51]
  52. [52]
    Difference Between Adsorption and Partition Chromatography
    Apr 2, 2018 · Adsorption chromatography separates compounds by adsorption while partition chromatography separates compounds by partition.
  53. [53]
    A Comparative Analysis Of Adsorption Chromatography And ... - alwsci
    Sep 11, 2025 · Adsorption chromatography excels in cases of large polarity differences, while partition chromatography is indispensable for subtle ...
  54. [54]
    Column chromatography - Columbia University
    The most common adsorbents used are silica gel and alumina. Silica gel is used to separate a wide variety of compounds such as hydrocarbons, alcohols, ketones, ...
  55. [55]
    Separation techniques: Chromatography - PMC - NIH
    Chromatography is an important biophysical technique that enables the separation, identification, and purification of the components of a mixture
  56. [56]
    Types of Chromatography | Bio-Rad
    Chromatography uses phase equilibrium partitioning principles to separate proteins, nucleic acids, or small molecules in complex mixtures based on their ...
  57. [57]
    Ion Exchange Chromatography - An Overview - IntechOpen
    Apr 10, 2013 · Discovery and history of chromatography [1, 2]. M. Tswett (1872-1919), a Russian botanist, discovered chromatography in 1901 during his ...
  58. [58]
    Mixed-Mode HPLC Separations: What, Why, and How | LCGC ...
    Mar 1, 2014 · Mixed-mode chromatography is a method that uses more than one separation mode; mainly reversed-phase combined with ion-exchange interactions, ...Missing: partition | Show results with:partition
  59. [59]
    C 18 fatty acids by reversed-phase partition chromatography
    The separation of the C12-C18 fatty acids by reversed-phase partition chromatography Available. G. A. Howard;. G. A. Howard. 1Medical Research Council Unit ...Missing: introduction | Show results with:introduction
  60. [60]
    New Horizons in Reversed-Phase Chromatography
    Reversed-phase chromatography can separate nonpolar, polar, ionizable, and ionic compounds, sometimes at the same time. For mobile phases, reversed-phase ...
  61. [61]
    Reverse Phase Liquid Chromatography - ScienceDirect.com
    Reversed-phase chromatography (RP-HPLC) uses a variety of stationary phases, the most common ones being octadecyl (C18 or ODS) which have octadecyl groups ...
  62. [62]
    What is the Role of LogP in Sample Prep Methods? - Biotage
    LogP, or octanol-water partition coefficient, is a measure of how hydrophilic or hydrophobic a molecule is. It indicates how readily an analyte will partition.
  63. [63]
    HPLC Column Technology: The First 50 Years | Labcompare.com
    Sep 28, 2018 · The availability of bonded siloxane phases had a particularly favorable fallout—the development of reversed-phase liquid chromatography (RPLC).
  64. [64]
    Continuing Innovations in Reversed-Phase Chromatography ...
    Here, I will focus on innovations in three areas: selectivity, stability and efficiency of commercially produced reversed-phase columns.
  65. [65]
    UHPLC: Advancements and Challenges | Danaher Life Sciences
    The utilization of sub-2 µm particle size columns in UHPLC systems significantly enhances separation efficiency. This finer particle size allows for a more ...Missing: 2020s | Show results with:2020s
  66. [66]
    Advances in ultra‐high‐pressure and multi‐dimensional liquid ...
    When these sub‐2 µm particles were used in gradient mode, a kinetic time‐gain factor of 13 was established for the separation of a complex mixture of waste‐ ...
  67. [67]
    Introduction to hyphenated techniques and their applications ... - NIH
    [1] GC-MS, which is a hyphenated technique developed from the coupling of GC and MS, was the first of its kind to become useful for research and development ...
  68. [68]
    Integration of Hyphenated Techniques for Characterizing and ...
    Apr 21, 2025 · Liquid–liquid chromatography (LLC) is a separation technique that uses the partitioning of substances between two immiscible liquid phases, a ...
  69. [69]
    Not (Only) Reversed-Phase Liquid Chromatography–Mass ...
    Nov 1, 2020 · The retention is driven by the partition of analytes between a polar stationary phase and a relatively hydrophobic mobile phase (for example ...
  70. [70]
    Recent Advances in Microfluidics-Based Chromatography—A Mini ...
    Microfluidics-based chromatography miniaturizes liquid chromatography on a microchip for on-chip separation, with applications in genomics, proteomics, and ...
  71. [71]
    Molecular Separation by Using Active and Passive Microfluidic chip ...
    Oct 27, 2023 · This review is about the microfludic-based methods that have been used in the past two decades for the separation of different biomolecules ...
  72. [72]
    [PDF] Simulated moving bed chromatography for the separation of ...
    Nov 1, 2008 · Simulated moving bed (SMB) chromatography, a continuous multi-column chromatographic process, has become one of the preferred techniques for ...
  73. [73]
    Chiral separations by simulated moving bed method ... - PubMed
    The simulated moving bed (SMB) method is one of the best popular practices of continuous chromatographic separation. In this chapter, I would like to introduce ...Missing: partition | Show results with:partition
  74. [74]
  75. [75]
    Preparative supercritical fluid chromatography as green purification ...
    1/Prevent waste through reduced solvent consumption: SFC uses supercritical fluids (between 5 and 50 % co-solvent, most of the time), which have low viscosity ...
  76. [76]
    Application of artificial intelligence to quantitative structure–retention ...
    Nov 26, 2024 · This review provides a comprehensive analysis of QSRR workflows and applications, with a special focus on the role of artificial intelligence.
  77. [77]
    In Silico High-Performance Liquid Chromatography Method ...
    Mar 28, 2025 · We propose a data-driven methodology to predict molecule retention factors as a function of mobile phase composition without the need for any new experiments.<|control11|><|separator|>
  78. [78]
    AI Holds Transformative Potential in Chromatography
    May 30, 2025 · AI can accelerate method development, enhance precision, predict optimal conditions, automate peak deconvolution, and extract insights from ...Missing: stationary selection partition