Fact-checked by Grok 2 weeks ago

Passive ventilation

Passive ventilation is the process of supplying to and exhausting stale air from indoor spaces using natural forces such as and thermal buoyancy, without relying on mechanical systems like fans or blowers. This method harnesses pressure differences generated by external and the —where warmer indoor air rises and escapes through upper vents, drawing in cooler outdoor air via lower inlets—to achieve adequate airflow rates, typically meeting standards like 0.35 () for residential applications. The core principles of passive ventilation revolve around two driving mechanisms: wind-driven flow, which exploits prevailing speeds (e.g., around 3 m/s) and directions to induce cross-room through operable windows or vents, and buoyancy-driven stack ventilation, which depends on indoor-outdoor gradients to create vertical air movement via dedicated stacks or chimneys. Systems are designed using analytical tools like loop equations (ΔP = ΔP_w + ΔP_s - ΣΔP_l, accounting for pressure, stack pressure, and losses) and (CFD) to optimize inlet/outlet sizing—such as 100-125 mm diameter stacks for bathrooms and kitchens—and ensure airtight building envelopes to prevent uncontrolled infiltration. Common types include single-sided ventilation for compact spaces, cross-ventilation across opposing walls, passive stack ventilation (PSV) with self-regulating terminals to maintain consistent flows (e.g., 0.033 m³/s), and enhanced variants like chimneys or towers that boost by 35-40% through heating or perforated designs. In architectural and practice, passive ventilation integrates with site , , and [thermal mass](/page/thermal mass) to minimize heat gain while promoting , particularly in mild climates where it can serve as the primary cooling strategy or supplement mechanical systems during outages. Benefits include substantial reductions in operational energy—up to 82% for cooling in residential buildings and 60% in commercial ones—along with improved through continuous fresh air supply and lower carbon emissions, without the maintenance demands of active HVAC. Originating from historical designs like 14th-century European castles, modern applications emphasize mixed-mode systems (e.g., in winter paired with passive summer operation) to comply with codes like and support sustainable goals in standards.

Fundamentals

Definition and Principles

Passive ventilation refers to the utilization of natural environmental forces, primarily and temperature differences, to supply to and exhaust stale air from indoor spaces in buildings without relying on powered mechanical devices. This approach leverages pressure differentials generated by these forces to drive airflow, promoting , , and in a sustainable manner. The fundamental principles governing passive ventilation center on and . Airflow occurs due to pressure differences: wind creates external pressure variations across building surfaces, drawing air inward through openings on the windward side and expelling it from the leeward side, as explained by , which posits that an increase in the speed of a fluid results in a corresponding decrease in its pressure. Complementing this, buoyancy-driven flow arises from temperature-induced density variations, where warmer indoor air rises because it is less dense than cooler surrounding air, in accordance with that a fluid exerts an upward buoyant force equal to the weight of the displaced fluid; this "stack effect" pulls cooler air in at lower levels and exhausts warmer air at higher elevations./Book%3A_University_Physics_I_-Mechanics_Sound_Oscillations_and_Waves(OpenStax)/14%3A_Fluid_Mechanics/14.06%3A_Archimedes_Principle_and_Buoyancy) In contrast to active ventilation systems, which employ fans, ducts, and electrical power to force air movement and often consume significant energy for heating, cooling, and distribution, passive ventilation operates without such inputs, thereby eliminating direct energy use and associated operational costs. This energy-free nature yields notable environmental advantages, including reduced reliance on fossil fuel-based electricity and lower carbon dioxide emissions, as mechanical systems can account for up to 50% of a building's energy consumption in conventional setups. Key components of passive ventilation systems include strategically positioned openings that enable the ingress and egress of air, such as operable windows for cross-flow, vents or louvers for controlled intake, atriums to amplify vertical paths, and chimneys to enhance exhaust through the . These elements must be sized and oriented to maximize natural forces while minimizing unwanted infiltration or heat loss.

Historical Development

Passive ventilation techniques trace their roots to ancient civilizations, where architectural innovations harnessed natural airflow for without mechanical aids. In around 1300 BCE, dwellings incorporated malqafs—tall, open shafts or reed vents that captured to induce cross-ventilation and evaporative cooling, often enhanced by wetting reeds hung in windows to lower indoor temperatures. Similarly, in ancient Persia, badgirs or windcatchers emerged as multi-story towers that funneled breezes into buildings while expelling hot air, relying on principles in stack vents to create upward airflow driven by temperature differences. The Romans, from the 3rd century BCE, adapted these concepts in systems, where underfloor and wall channels circulated warm air passively through combustion-heated flues, providing both heating and ventilation in public baths and villas. During the medieval and periods, passive ventilation evolved through regional adaptations that integrated wind-driven and stack effects into everyday structures. In the , windcatchers and malqafs persisted and refined in , such as in medieval Cairo's wind towers that directed airflow into homes and hospitals for cooling and air purification. In , from the onward, defensive towers and designs in and incorporated courtyards and high chimneys to exploit for expelling stale air. These features emphasized cultural exchanges along trade routes, blending and influences with innovations for habitable interiors in diverse climates. The 19th and 20th centuries saw passive ventilation integrated into industrial and residential scales amid rapid . During the , factories in and relied on operable windows, roof vents, and chimney stacks for natural airflow to mitigate heat and fumes from machinery, predating widespread mechanical systems. Post-World War II, the catalyzed a shift toward energy-efficient designs; the passive solar movement in the United States and promoted buildings with strategic openings for natural ventilation alongside , reducing reliance on fossil fuels and inspiring global standards for low-energy architecture. In recent decades up to 2025, passive ventilation has experienced a revival in , driven by environmental imperatives and certification frameworks. The (Passivhaus) standard, formalized in in the 1990s by the Passivhaus Institute in , emphasizes airtight envelopes with controlled natural ventilation to achieve ultra-low energy use, influencing thousands of projects across the continent. This aligns with certifications from the U.S. Green Building Council, which reward passive strategies in net-zero buildings, and the European Union's 2020 mandate for nearly-zero energy buildings, escalating to zero-emission standards by 2030 to combat , increasingly incorporating historical passive techniques like windcatchers in modern designs.

Mechanisms

Wind-Driven Ventilation

Wind-driven ventilation harnesses the of outdoor to induce through building openings by creating differentials across the envelope. As wind approaches a building, it imparts positive on the windward facade, compressing air and forcing it inward through vents or windows, while the leeward side experiences due to and wake formation, drawing air out. This mechanism promotes the exchange of indoor and outdoor air without mechanical assistance, enhancing occupant comfort and in passive systems. The magnitude of the driving is determined by the velocity of the wind, expressed as
P = 0.5 \rho v^2
where \rho is the air density (typically 1.2 /m³ at standard conditions) and v is the wind speed at reference height. This is modulated by external pressure coefficients (C_p), which account for building and location, yielding net differentials of approximately 10 for moderate winds of 4 m/s.
Key types of wind-driven ventilation include cross-ventilation, single-sided ventilation, and courtyard ventilation. In , openings on opposing facades enable direct paths, with inlet s on the windward side and outlets on the leeward, achieving higher flow rates suitable for deep-plan spaces. Single-sided ventilation relies on openings clustered on one facade, where and induced drive short-circuit flows between adjacent vents, though effectiveness diminishes with distance from the facade. Courtyard ventilation leverages an internal atrium or courtyard to funnel , generating localized gradients that distribute air to surrounding rooms via peripheral openings. Several factors influence the performance of wind-driven . directly scales the , with higher velocities increasing airflow but potentially causing discomfort from drafts. dictates facade exposure, requiring buildings to be oriented perpendicular to for optimal capture. Local , such as hills or urban canyons, can accelerate or deflect winds, altering distributions around the structure. These variables necessitate site-specific analysis to predict reliable ventilation rates. To enhance wind-driven flows, designers incorporate features that amplify or direct pressures. Wing walls, protruding extensions adjacent to windows, create localized high-velocity jets that penetrate deeper into rooms, extending effective ventilation to single-sided configurations. Louvers and adjustable grilles regulate inflow direction and volume, mitigating issues like rain penetration while maintaining airflow. Overhangs not only shade but also guide wind toward lower openings, boosting inlet pressures in low-rise buildings. Such elements can increase ventilation efficacy in varied wind conditions.

Buoyancy-Driven Ventilation

Buoyancy-driven ventilation, commonly referred to as stack ventilation, relies on the to generate airflow through temperature-induced density differences in air. When indoor air is heated—by sources such as , occupants, or equipment—it becomes less dense than cooler outdoor air, causing it to rise naturally toward higher elevations within the building. This upward movement creates a imbalance: reduced pressure at the top draws warm air out through upper openings like vents or chimneys, while the resulting lower pressure at the base pulls in cooler, denser air through lower-level inlets. The process establishes a continuous vertical circulation that promotes fresh air exchange and without relying on mechanical systems. Stack ventilation systems can be configured in various ways to optimize paths. Single-stack designs utilize a central vertical exhaust shaft, where warm air rises through the stack and cooler air enters via surrounding lower room openings, drawing fresh air into the spaces and simplifying construction. Double-stack configurations employ distinct inlet and outlet paths, with dedicated lower inlets feeding into a space and separate upper exhaust stacks, which minimize recirculation and enhance directed . Solar chimneys represent an advanced variant, where the stack incorporates glazing or dark surfaces to capture solar radiation, intensifying the internal rise and thereby boosting the buoyancy-driven . The fundamental driving force is the hydrostatic pressure difference arising from the density contrast, expressed as
\Delta P = \rho g h \frac{\Delta T}{T}
where \rho is the , g is the , h is the of the stack, \Delta T is the temperature difference between indoor and outdoor , and T is the absolute outdoor . This propels the vertical , with the magnitude scaling linearly with stack height and temperature differential.
Performance of buoyancy-driven ventilation is governed by several interrelated factors, including stack height, which amplifies the difference for greater flow potential; the , which provides the essential force; and opening sizes, which influence resistance and volume—typically requiring balanced areas to prevent bottlenecks. These systems prove less viable in low-rise buildings, where limited height constrains the achievable differential, often resulting in inadequate rates. In hybrid applications, can briefly augment stack flows to compensate for subdued under neutral conditions.

Design and Implementation

Architectural Features

Architectural features for passive ventilation emphasize the strategic integration of physical elements to harness natural airflow without mechanical assistance. Openings such as windows, vents, and grilles are positioned to establish clear airflow paths, with cross-ventilation achieved by placing operable windows on opposite building sides to facilitate direct wind movement through occupied spaces. Atriums function as vertical conduits, linking ground-level inlets to upper outlets to promote buoyancy-driven circulation, while strategies involve selective opening of lower-level vents at night for purging accumulated heat and closing them during the day to minimize solar ingress. Grilles in walls or ceilings further refine these paths by distributing air evenly across zones, ensuring consistent indoor comfort. Structural elements like courtyards, light wells, and monitors enhance capture and stack effects by creating enclosed or elevated volumes that amplify natural forces. Courtyards, when designed with optimal aspect ratios, boost in warm climates by channeling breezes inward and promoting evaporative cooling through shaded, open interiors. Light wells penetrate deep into buildings to draw in fresh air and exhaust stale air via gradients, while monitors—raised sections with vents—serve as exhaust points to accelerate upward . These features, including brief applications of in solar chimneys, integrate seamlessly to support both - and temperature-driven . Materials and controls play a vital role in modulating while addressing environmental challenges. Operable shutters and dampers enable manual or automated adjustment of opening sizes to respond to varying speeds or temperatures, optimizing rates without energy input. screens fitted to vents and windows maintain barrier protection against pests while preserving airflow continuity, and their fine mesh ensures minimal resistance to breeze entry. Shading integrations, such as adjustable louvers over windows, complement these by blocking direct to avert overheating, thereby sustaining effective alongside . Site considerations significantly influence the efficacy of these features, particularly through building orientation and contextual dynamics. Orienting structures so their shorter axis aligns perpendicular to maximizes facade exposure and internal penetration. In settings, dense surroundings reduce velocities and introduce , diminishing potential compared to rural sites where open landscapes permit stronger, more consistent breezes. Thus, site-specific adaptations, like elevated inlets in cities, are essential to mitigate these impacts and sustain passive performance.

Calculation Methods

The fundamental approach to calculating airflow rates in passive ventilation systems relies on the orifice equation derived from Bernoulli's principle, which models flow through openings as Q = C_d A √(2 ΔP / ρ), where Q is the volumetric flow rate (m³/s), C_d is the discharge coefficient (typically 0.6–0.65 for sharp-edged openings), A is the effective opening area (m²), ΔP is the pressure difference across the opening (Pa), and ρ is the air density (approximately 1.2 kg/m³ at standard conditions). This equation assumes incompressible flow and is applicable to both inflow and outflow, with the direction determined by the sign of ΔP; it forms the basis for predicting ventilation rates in simple configurations but requires specification of ΔP from driving forces like wind or buoyancy. For wind-driven ventilation, the pressure difference ΔP is calculated as ΔP = 0.5 ρ V² (C_{p,in} - C_{p,out}), where V is the wind speed at reference height (m/s), and C_p values are external pressure coefficients (ranging from -1.5 for leeward sides to +0.8 for windward, depending on building geometry, wind direction, and terrain). These C_p values are often obtained from empirical correlations or wind tunnel data, with adjustments for wind angle θ (e.g., maximum ΔP at θ = 0° for cross-ventilation). To account for annual variability, wind rose diagrams—polar plots of prevailing wind speeds and directions from meteorological data—are used to compute time-averaged airflow rates by integrating over directional probabilities, enabling designers to size openings for typical site conditions like those in subtropical climates where southeast winds dominate. In buoyancy-driven ventilation, the stack effect generates ΔP through density differences, given by ΔP = (ρ_out - ρ_in) g H, where ρ_out and ρ_in are outdoor and indoor air densities (kg/m³), g is gravitational acceleration (9.81 m/s²), and H is the vertical height between openings (m). Since ρ_in ≈ ρ_out (1 - ΔT / T_in), where ΔT is the indoor-outdoor temperature difference (K) and T_in is the average indoor temperature (K), this simplifies to ΔP ≈ ρ_out g H (ΔT / T_in), with flow rates increasing nonlinearly with height and temperature differential (e.g., ΔT = 5–10 K yields modest ΔP of 1–5 Pa over H = 3 m). The neutral pressure plane, where ΔP = 0, shifts based on opening areas, requiring iterative solution of the orifice equation for bidirectional flows. For systems combining and , such as single-sided or cross-ventilation under variable conditions, iterative methods solve for coefficients and net flows by balancing mass conservation across zones, often using algebraic models like AIM-2, which superposes and contributions with empirical adjustments for interaction (e.g., opposing reduces effective ΔP by up to 50% at low speeds). These methods employ power-law relations Q ∝ ΔP^n (n ≈ 0.5–0.65) and converge in 5–10 iterations for multi-zone , achieving errors below 15% for -dominated cases and 7% for -dominated ones when validated against measurements. Advanced predictions for complex geometries incorporate software tools, with EnergyPlus's Airflow Network module simulating multi-zone natural ventilation by integrating the orifice equation with network solvers for pressure-flow balances, supporting mixed-mode controls and updated to version 25.1.0 in 2025 for enhanced natural ventilation modeling including wind sheltering and interactions. For detailed flow patterns, (CFD) simulations couple with EnergyPlus via co-simulation frameworks to resolve and local velocities, as in subtropical designs where CFD optimizes opening placements for 20–30% airflow gains, adhering to standards like 90.1-2022 for passive systems. These tools prioritize annual over isolated calculations, with validation against on-site ensuring accuracy within 10–20%.

Performance Evaluation

Assessment Techniques

Assessment techniques for passive ventilation involve empirical and simulated methods to evaluate , air quality, and occupant comfort in buildings, ensuring systems perform as intended without mechanical aids. Field measurements provide direct validation of ventilation effectiveness in real-world conditions, while modeling approaches offer predictive insights. Key metrics quantify performance, and emerging tools enable ongoing assessment. Field measurements employ instruments such as anemometers to capture air velocities at openings and within spaces, helping to determine airflow rates driven by wind or buoyancy. Pressure sensors measure differential pressures across building envelopes to assess driving forces for natural airflow, often compared against tracer gas results for accuracy in urban settings. Tracer gas techniques, including decay and constant concentration methods, quantify ventilation rates and air distribution by releasing inert gases like SF6 or CO2 and monitoring their dilution, widely used for natural ventilation evaluation in occupied buildings. Modeling approaches include (CFD) simulations, which solve Navier-Stokes equations to predict airflow patterns, velocities, and distributions under various wind conditions and geometries. wind tunnel testing replicates site-specific wind profiles on reduced-scale building models to measure pressure coefficients and ventilation rates, validating designs before construction. Performance is evaluated using metrics like air change rates (), calculated as the volume of introduced per hour relative to the space volume, indicating overall ventilation efficacy. (IAQ) indicators, such as CO2 concentration levels, serve as proxies for ventilation adequacy, with elevated levels signaling insufficient airflow. Thermal comfort indices, including the Predicted Mean Vote (PMV), assess occupant satisfaction by integrating air speed, , and data from passive systems. Post-2020, sensors have gained prominence in smart buildings for of , integrating networks of low-cost devices to track airflow, CO2, and environmental parameters, enabling data-driven adjustments. These tools support continuous performance verification, distinct from initial theoretical calculations that inform preliminary designs.

Standards and Regulations

systems must comply with established international standards that specify minimum ventilation rates to ensure acceptable (IAQ). The American Society of Heating, Refrigerating and Air-Conditioning Engineers () Standard 62.1-2025, titled "Ventilation for Acceptable ," outlines prescriptive requirements for ventilation, including the Ventilation Rate Procedure (VRP) that allows passive methods to meet outdoor air needs in suitable climates by providing operable openings with a total openable area equivalent to at least 4% of the net occupiable , applicable to single-sided or cross-ventilation configurations. In , EN 15251:2007, developed by the (CEN), provides criteria for indoor environmental parameters, including ventilation rates for non-residential buildings that integrate passive strategies to achieve Category I, II, or III IAQ levels, emphasizing design values for and air quality without mechanical reliance where feasible. The 2024 International (IBC), Section 1202.5, permits ventilation as an alternative to mechanical systems, requiring operable openings with a minimum net clear area of 4% of the served, updated to enhance integration with provisions in response to evolving building performance needs. Building codes and green certification programs further incorporate passive ventilation requirements to promote . The Leadership in Energy and Environmental Design () v5 rating system, released in 2025 by the U.S. Green Building Council (USGBC), incorporates options for passive strategies in its Indoor Environmental Quality prerequisites, allowing credits for natural ventilation designs that meet 62.1-2025 while emphasizing resilience through adaptive envelope features and reduced mechanical dependency. Local variations, such as California's Title 24, Part 6 (2022 Energy Code), require ventilation in nonresidential buildings per 62.1 but credit passive systems with operable openings comprising at least 5% of for compliance in low-rise structures, integrating these with overall to minimize active systems. Compliance testing for passive ventilation involves standardized protocols to verify effective paths and opening functionality. Under 62.1-2025's natural compliance path, requires documentation of opening areas (minimum 4% of ), exposure analysis, and post-occupancy verification using tracer gas or measurements to confirm dilution rates meet intent, often coordinated with local building officials for permit approval. These protocols, echoed in EN 15251's Annex B, include field testing for operable area and obstruction-free paths, ensuring passive systems deliver rates compliant with the standard. The latest edition, 62.1-2025, introduces enhancements such as mandatory air adjustments and expanded options that can integrate with passive ventilation monitoring. Global trends in the reflect a shift toward climate-adaptive standards driven by international policies addressing rising temperatures and . Frameworks like the and UN emphasize passive ventilation in building codes to enhance thermal resilience, with updates to standards such as EN 15251 revisions incorporating future climate projections for ventilation efficacy in warmer scenarios. Similarly, the 2024 IBC and v5 integrate adaptive credits for passive systems that perform under projected heat indices up to 32°C, prioritizing low-energy strategies in response to policies like the Paris Agreement's net-zero targets.

Applications and Benefits

Building Types and Examples

Passive ventilation has been integral to residential architecture in various climates, particularly in traditional vernacular designs. In Indian havelis of , central courtyards surrounded by high building masses and verandas facilitate natural airflow, drawing in cooler air from shaded areas while expelling warm air through stack effects to maintain without mechanical systems. Modern residential examples include the Darmstadt Kranichstein Passive House prototype in , built in the 1990s as the world's first certified , which incorporates controlled ventilation with heat recovery alongside passive strategies like airtight envelopes and insulation to minimize energy use for air exchange. In commercial and office buildings, passive ventilation often leverages atriums and strategic openings to harness wind and buoyancy. The in , completed in 1997, features a central atrium functioning as a natural ventilation chimney, with sky gardens and operable facades enabling cross-ventilation for inward-facing offices regardless of wind direction. Educational and public buildings in temperate and urban settings demonstrate passive ventilation's adaptability to mixed-use environments. The project in , developed in 2002, includes a college and community facilities with natural ventilation cores that promote airflow through building orientation and openings, supporting passive cooling in a dense urban context. Recent net-zero office developments in Singapore address tropical urban heat islands through hybrid passive systems. The Oasia Hotel Downtown, a mixed-use tower completed in 2016 but emblematic of ongoing sustainable practices into the 2020s, integrates sky gardens and breezeway atria for natural cross-ventilation, reducing reliance on air conditioning while achieving Green Mark Platinum certification.

Advantages and Limitations

Passive ventilation provides substantial energy savings by leveraging natural airflow to minimize reliance on mechanical heating, ventilation, and air conditioning (HVAC) systems, with studies indicating reductions in energy consumption ranging from 10% to 45% across major global cities. It enhances indoor air quality (IAQ) by facilitating the influx of fresh outdoor air, which dilutes indoor pollutants such as carbon dioxide and volatile organic compounds, thereby reducing health risks associated with poor ventilation. Additionally, passive systems require low maintenance due to the absence of moving parts like fans or motors, and they operate noise-free, contributing to occupant comfort without the audible disturbances common in mechanical alternatives. From an environmental perspective, passive ventilation lowers embodied carbon emissions by avoiding energy-intensive mechanical components, which can account for a significant portion of a building's lifecycle when using durable, low-impact materials for vents and openings. This approach aligns with Sustainable Development Goals (SDGs), particularly SDG 7 (Affordable and Clean Energy) through reduced operational energy demands and SDG 13 (Climate Action) by curbing from building operations. Despite these benefits, passive ventilation exhibits limitations in reliability, as its effectiveness depends on external weather conditions; in calm winds or extreme temperatures, may be insufficient, leading to inadequate or thermal discomfort. It can also introduce drafts, allergens like , or outdoor pollutants through uncontrolled openings, potentially compromising IAQ in sensitive environments. Furthermore, the risk of overheating arises in hot climates without sufficient adaptations, and initial implementation typically incurs lower costs compared to systems due to the absence of , though specialized architectural features may add to expenses. To address these drawbacks, hybrid systems that integrate passive ventilation with minimal mechanical backups have emerged in the as adaptive mitigation strategies, allowing seamless transitions to powered assistance during unfavorable conditions while preserving .

References

  1. [1]
    None
    Below is a merged summary of AIVC Technical Note 54: Residential Passive Ventilation Systems, combining all information from the provided segments into a single, comprehensive response. To retain maximum detail, I’ve organized key information into a dense, tabular format where appropriate (e.g., for types of systems, design considerations, and technical facts), while maintaining a narrative structure for definitions, principles, and benefits. The response includes all specifics, such as measurements, standards, historical context, and URLs, ensuring no information is lost.
  2. [2]
    Passive cooling techniques for ventilation: an updated review
    Aug 2, 2022 · The main advantage of passive cooling is to minimize energy demands which are required to achieve thermal comfort in buildings, especially with ...Missing: definition | Show results with:definition
  3. [3]
    Passive and Low-Energy Cooling | Building America Solution Center
    Sep 30, 2022 · Passive and low-energy cooling uses less energy than standard AC, sometimes none, using cool air, evaporation, ground, and thermal radiation. ...
  4. [4]
    [PDF] Passive Design Toolkit
    “Passive design”2 is an approach to building design that uses the building architecture to minimize energy consumption and improve thermal comfort. The building ...<|control11|><|separator|>
  5. [5]
    Natural Ventilation - Department of Energy
    Natural ventilation relies on the wind and the stack effect, also known as the chimney effect, to cool a home without using HVAC equipment.
  6. [6]
    Passive Ventilation: Stack Effect & Bernoulli's Principle - SimScale
    What Is Passive Ventilation? Passive or natural ventilation supplies and removes air from indoor spaces without the assistance of mechanical systems. Passive ...Missing: definition | Show results with:definition
  7. [7]
  8. [8]
    Dwelling house in Ancient Egypt with wind catcher (1300 BC)
    Wind towers have been in existence in various forms for centuries as wind-catchers in Saudi Arabia, malqaf in Egypt or badgir in Persia (Iran) several shapes to ...Missing: roman hypocaust
  9. [9]
    The Ancient Roots of Air Conditioning: A Journey Through Time
    Aug 8, 2024 · Persia (Modern-day Iran): Windcatchers and Natural Cooling. The Persians developed an architectural marvel known as the “badgir” or windcatcher.
  10. [10]
    [PDF] Ancient Iran, the Origin Land of Wind Catcher in the World
    Aug 20, 2013 · Arabic form of the Persian word Badgir (wind catcher). Moreover, the first wind catchers of United Arab. Emirates have been built in Bastak ...
  11. [11]
    [PDF] Why We Ventilate Our Houses – An Historical Look - OSTI.GOV
    The Romans (3rd century BC) developed the hypocaust heating system by combining ventilation with combustion. These systems were originally used to heat public ...
  12. [12]
    The Rise and Evolution of Wind Tower Designs in Egypt and ... - MDPI
    Additionally, windcatchers were used widely during the Egyptian Medieval era and were known as a malqaf, literally meaning “catcher”.
  13. [13]
    Windmills in Medieval Europe - COVE
    Windmills were introduced to Europe in the 13th century, used for pumping water, sawing wood, and grinding grain, especially for those not near rivers.
  14. [14]
    (PDF) A Review to Innovative Ventilation Techniques Used in ...
    Aug 6, 2025 · In this context, this study investigated systematically, passive ventilation techniques used in medieval near eastern hospitals ”Bimaristans” ...
  15. [15]
    [PDF] preservation-brief-24-heating-cooling.pdf - National Park Service
    Eighteenth century and later vernacular architecture depended on the siting of the building, deciduous trees, cross ventilation, and the placement of windows ...
  16. [16]
    The History of Passive House: A Global Movement with North ...
    Jun 23, 2017 · The innovative concepts behind the passive house movement originated in the United States and Canada following the oil embargo of 1973.Missing: 20th century revolution
  17. [17]
    The History of Passive House / Passivhaus | EnvironBuzz™ Magazine
    Aug 25, 2023 · The concept of the Passive House was first formally created in 1996's Passivhaus Institute in Darmstadt, Germany by Dr. Wolfgang Feist.
  18. [18]
    [PDF] USGBC Impact Report
    Net Zero Performance Certification: A program under. LEED that targets net zero performance in carbon, energy, water, and waste. Low-Emission ...
  19. [19]
    Nearly-zero energy and zero-emission buildings
    Since 2020, all new buildings in the EU are required to be 'nearly-zero energy buildings'. This will be replaced by a further enhanced 'zero-emission buildings ...
  20. [20]
    The State of Passive House in 2025 - SABMag
    Apr 10, 2025 · As we find ourselves well into 2025, the landscape of sustainable building practices continues to undergo profound transformation.Missing: ventilation europe 1990s
  21. [21]
    [PDF] Application of Natural Ventilation for US Commercial Buildings ...
    Mar 20, 2018 · which were originally inspired by earlier German precedents and much earlier Roman hypocaust methods – provide the most conspicuous example ...
  22. [22]
    Single-sided natural ventilation driven by wind pressure and ...
    Single-sided natural ventilation driven by wind pressure and temperature difference ... energy-efficient and healthy ventilation strategies in buildings: A ...
  23. [23]
    [PDF] Optimization of Natural Ventilation Design in Hot and Humid ... - CORE
    - Cross ventilation: based on wind-driven forces caused by wind-induced pressure difference at ventilation openings, on opposite sides of an enclosed space.
  24. [24]
    [PDF] Energy-Efficient Florida Home Building - Fsec .ucf .edu
    Wingwalls (walls that protrude out from the house, next to the window) can be used to improve ventilation. A wingwall should be as long as the window is ...
  25. [25]
    [PDF] THE FLUID MECHANICS OF NATURAL VENTILATION
    The next two sections will discuss wind-driven and buoyancy-driven ventilation. Single-sided ventilation will be examined in Section 4, and some effects of wind ...
  26. [26]
    Natural Ventilation in Historic Buildings Can Save Energy
    Dec 5, 2024 · Cross ventilation, opening windows on opposite sides of the building to improve airflow and regulate indoor temperature; Stack ventilation, ...
  27. [27]
    [PDF] Passive Heating & Cooling Design for the 21st Century
    Natural Ventilation Design Intent: Air from corridors is intended to flow into the central atrium, up, and out through rooftop vents (SRG Architecture). Stack ...
  28. [28]
    Towards the new generation of courtyard buildings as a healthy ...
    A good combination of courtyard layout and aspect ratio can improve the use of natural ventilation by increasing free cooling during hot summer and reducing ...
  29. [29]
    [PDF] the first passive solar home awards - HUD User
    CONTROLS: Operable shutters, vents, windows, and doors. BACKUP: 50,000 BTUH ... CONTROLS: Operable dampers, fans, vents, and panels. BACKUP: 100,000 BTUH ...
  30. [30]
    [PDF] Optimization of a solar chimney design to enhance natural ...
    Solar chimneys (SC) are passive elements that make use of the solar energy to induce buoyancy-driven airflow and naturally ventilate the building. A SC differs ...
  31. [31]
    [PDF] Passive Solar Design Strategies: Guidelines for Home Building
    Operable windows and/or vent openings should be located for effective cross-ventilation, and to take advantage of the prevai1ing summer wind. Low inlets and ...
  32. [32]
    [PDF] Evaluation of Passive Vents in New Construction Multifamily Buildings
    Feb 5, 2016 · This strategy uses engineered passive vents in the exterior envelope to provide ventilation air from the outside. Exhaust in apartments is ...
  33. [33]
    Passive Solar Design - Sustainability - Williams College
    At their simpliest, passive solar cooling systems include overhangs or shades on south facing windows, shade trees, thermal mass and cross ventilation. ...
  34. [34]
    [PDF] Massing and Building Orientation IN THE PASSIVE DESIGN ...
    Notice how when the building is oriented so that the larger surface faces the wind, the building is receiving more wind ventilation. Orienting the building so ...
  35. [35]
    Urban environment influence on natural ventilation potential - ADS
    Natural ventilation is less effective in urban than in rural environment, especially in street canyons. Reduced wind velocity, urban heat island, noise and ...<|control11|><|separator|>
  36. [36]
    From street canyon microclimate to indoor environmental quality in ...
    The microclimate in urban street canyons is characterized by low wind speed, high surface temperature difference, high pollutant concentration, and high noise ...
  37. [37]
    [PDF] Procedures for Calculating Natural Ventilation Airflow Rates in ...
    The Vickery model starts with the standard orifice flow equation through the ith aperture. Note: In this procedure, aperture means the sum of all open areas ...
  38. [38]
    Natural Ventilation | Green Home Technology Center
    Natural ventilation uses wind and thermal buoyancy to move air in and out of a home without mechanical systems, bringing in fresh air.Missing: mechanism | Show results with:mechanism
  39. [39]
    [PDF] A general routine analysis of stack effect
    Stack effect also applies to the buoyancy driven flows between a room on fire and its surroundings. The methods of analysis of this paper can also be used ...
  40. [40]
    Field Validation of Algebraic Equations for Stack and Wind Driven ...
    The AIM-2 model had bias and scatter errors of less than 15% for wind-dominated ventilation, and less than 7% for buoyancy ("stack-effect") dominated cases.Missing: formula | Show results with:formula<|separator|>
  41. [41]
    [PDF] EnergyPlus 23.1.0 - Department of Energy
    The EnergyPlus software models natural ventilation. (ii) Mixed mode (natural and mechanical) ventilation. The EnergyPlus software models mixed ...
  42. [42]
    Combining EnergyPlus and CFD to predict and optimize the passive ...
    This work combining the building energy modeling (BEM) and computational fluid dynamics (CFD) to evaluate the impact of climatic conditions and building forms ...
  43. [43]
    Standards 62.1 & 62.2 - ashrae
    Standard 62.1 specifies minimum ventilation rates and other measures intended to provide indoor air quality (IAQ) that's acceptable to human occupants and that ...
  44. [44]
    REHVA Journal Revision of EN 15251: Indoor Environmental Criteria
    EN15251 is the first European standard that includes criteria for the four indoor environmental factors: Thermal comfort, air quality, lighting, and acoustic.
  45. [45]
    2024 International Building Code (IBC) - 1202.5 Natural ventilation.
    The 2024 IBC® applies to all buildings except detached one- and two-family dwellings and townhouses up to three stories. The 2024 IBC® contains many important ...Missing: credits | Show results with:credits
  46. [46]
    [PDF] Summary of changes to LEED v5 U.S. Green Building Council
    Removed the following strategies: interior cross contamination prevention, natural ventilation design calculations, mixed-mode design calculations, exterior ...
  47. [47]
    REQUIREMENTS FOR VENTILATION AND INDOOR AIR QUALITY
    Section 120.1 requires ventilation for most occupiable spaces, with air filtration, minimum outdoor air rates, and specific air classification rules. ...
  48. [48]
  49. [49]
    [PDF] Revision of EN 15251: Indoor Environmental Criteria - rehva
    Abstract: EN15251 specifies indoor environmental input parameters for design and assess- ment of energy performance of buildings addressing indoor air quality, ...
  50. [50]
    Climate adaptability of building passive strategies to changing future ...
    Jun 17, 2025 · This review focuses on how passive strategies can assist buildings in adapting to urban climate change while improving building energy ...
  51. [51]
    [PDF] The Role of Cooling Standards in Climate Adaptation to Extreme Heat
    Moreover, in the context of climate change adaptation, passive cooling standards are essential in ensuring that vulnerable populations have access to thermal ...Missing: 2020s | Show results with:2020s
  52. [52]
    [PDF] Climatic Responsiveness and Thermal Comfort of Havelis - ISVS
    Apr 2, 2022 · The natural and passive systems in buildings use non-mechanical methods to maintain a comfortable indoor temperature and are a key factor in ...
  53. [53]
    The world's first Passive House, Darmstadt-Kranichstein, Germany
    Feb 8, 2024 · Ventilation. Heat Recovery. A Passive House in the Central European Climate can only function with a controlled ventilation system with highly ...
  54. [54]
    Commerzbank Headquarters | Projects - Foster + Partners
    Environmentally, they bring light and fresh air into the central atrium, which acts as a natural ventilation chimney for the inward-facing offices. Depending on ...
  55. [55]
    [PDF] Oasia Hotel Downtown, Singapore: A Tall Prototype for the Tropics
    the tower comprises lushly landscaped sky terraces, inserted in naturally ventilated breezeway atria between room blocks. These provide guests and occupants.
  56. [56]
    A fresh (air) look at ventilation for COVID-19: Estimating the global ...
    This combination decreases energy costs by 10–45% in 60 major cities globally, while increasing fresh air intake. Nomenclature. A. Specific energy of outdoor ...
  57. [57]
    Improving Indoor Air Quality | US EPA
    Sep 9, 2025 · Natural ventilation can also improve indoor air quality by reducing pollutants that are indoors. Examples of natural ventilation are: opening ...
  58. [58]
    Passive Ventilation for Tension Fabric Buildings
    Dec 13, 2023 · No noise; Better indoor air quality; Virtually no operation or maintenance time or cost since there are no moving parts; Ability to maintain a ...
  59. [59]
    [PDF] Low Embodied Carbon Ventilation Systems for Healthy Learning ...
    The passive system T1 is mainly wind-driven, but the localised fresh air supply may be heterogeneous and cause discomfort during winter. Its emissions depend on ...<|separator|>
  60. [60]
    Passive House and the Sustainable Development Goals (SDGs)
    Jun 30, 2021 · The Passive House Standard contributes to SDG 1 in two main ways: Firstly, Passive House makes a notable contribution to social housing and reducing energy ...
  61. [61]
    Passive Ventilation Explained in 2025 - The Eco Experts
    Jan 5, 2024 · Passive ventilation is a way of combining building techniques and natural elements to increase airflow and regulate air temperature within a building.
  62. [62]
    Air Quality in the Built Environment - World Green Building Council
    Where outdoor air is polluted, natural or passive ventilation strategies are often unsuitable due to ingress of polluted air and the health risks this would ...
  63. [63]
    A Systematic Review on the Risk of Overheating in Passive Houses
    This review indicates that PHs are considered at risk of overheating in the hot periods of the year across many climatic regions, exacerbated by the impacts of ...
  64. [64]
    Advancing hybrid ventilation in hot climates: a review of current ...
    Jan 5, 2025 · Soebiyan (2021) reported that hybrid systems save 50% of energy in hot, arid climates, compared to 60%–70% in temperate regions and 28% in warm, ...Missing: 2020s | Show results with:2020s