Fact-checked by Grok 2 weeks ago

Refrigerant

A refrigerant is a specialized fluid used in vapor-compression refrigeration, air-conditioning, and heat pump systems, where it cycles between liquid and vapor phases to absorb heat at low temperatures and release it at higher temperatures, enabling efficient thermal energy transfer against natural gradients. Essential properties include a suitable boiling point under operational pressures, high latent heat of vaporization, and chemical stability, though ideal candidates also minimize toxicity, flammability, ozone depletion potential (ODP), and global warming potential (GWP). These substances underpin cooling technologies critical for food preservation, climate control in buildings, and industrial processes, with applications spanning domestic refrigerators to large-scale chillers. The evolution of refrigerants reflects a progression from early hazardous options like and —effective but prone to leaks causing toxicity risks—to synthetic chlorofluorocarbons (s) introduced in the 1930s for their inertness and safety. Empirical atmospheric measurements linked CFCs to stratospheric , with column reductions observed correlating to rising CFC concentrations, leading to the 1987 Montreal Protocol's phased global elimination of ozone-depleting substances. Hydrochlorofluorocarbons (HCFCs) served as interim replacements with lower ODP, but high-GWP hydrofluorocarbons (HFCs) dominated post-CFC era, now targeted for reduction under the due to their potent effects—exemplified by HFC-134a's GWP of 1430 over 100 years. Contemporary shifts prioritize low-GWP alternatives, including hydrofluoroolefins (HFOs) with GWPs under 1 owing to and shorter lifetimes, alongside natural refrigerants like (GWP 1) and hydrocarbons for specific uses despite flammability constraints. Observed declines in HCFC and levels alongside HFC increases underscore regulatory efficacy and ongoing challenges in mitigating from these cycles. This trajectory embodies causal trade-offs between thermodynamic performance, safety, and planetary boundary conditions, with peer-reviewed assessments confirming protocol-driven recovery trajectories.

Fundamentals

Definition and Role in Vapor-Compression Cycles

A refrigerant is a employed in systems to absorb from a low-temperature and reject it to a higher-temperature sink, enabling cooling or heat pumping through repeated changes between and vapor states. These fluids are characterized by suitable thermodynamic properties, such as low boiling points at operational pressures, high latent heats of , and stability under cyclic and . In the vapor-compression cycle—the most common mechanical refrigeration process—the refrigerant circulates through four primary components: , , , and expansion device. In the , the refrigerant enters as a low-pressure liquid-vapor and absorbs from the cooled medium, fully vaporizing and often slightly; this endothermic phase change drives the cooling effect. The resulting low-pressure vapor is then compressed by the to and , increasing its and preparing it for heat rejection. Upon entering the , the superheated high-pressure vapor transfers to the ambient or cooling medium, condensing into a subcooled liquid while releasing . The liquid refrigerant subsequently passes through the expansion valve or , where it undergoes isenthalpic expansion, reducing and to complete the back to the . The refrigerant's in this is quantified by metrics like the (), which depends on its pressure-temperature relationship and minimizes irreversible losses during transitions. This closed-loop allows net against a thermal gradient, with the refrigerant's selection critically influencing system capacity, energy use, and operational reliability.

Key Thermodynamic Properties

The thermodynamic performance of refrigerants in vapor-compression cycles hinges on properties such as the normal boiling point, critical temperature, , and saturation vapor pressure curve, which collectively determine operating pressures, , compression work, and (). These properties must align with evaporator temperatures (typically -40°C to 5°C) and condenser temperatures (30°C to 60°C) to optimize and while minimizing compressor size and input. The normal —the at which the refrigerant vaporizes at 1 atm (101.3 kPa)—should be low enough to facilitate evaporation at sub-atmospheric pressures in the . Values below 0°C are generally desirable; for example, R-134a boils at -26.1°C, enabling effective low-temperature operation in automotive and domestic systems without excessive . The critical must exceed the highest anticipated condensing by at least 20-40°C to maintain subcritical condensation and avoid elevated pressures or inefficient supercritical behavior. Refrigerants like R-134a, with a critical of 101.1°C, support condensing up to approximately 70°C before approaching critical limits, though practical margins prioritize lower values for safety and efficiency. Latent heat of at evaporator conditions governs the refrigerating effect ( difference across the ), with higher values yielding greater heat absorption per unit and thus higher volumetric . Typical desirable magnitudes from 150 to 250 kJ/kg, though on a basis, latent heats are roughly constant for fluids with comparable boiling points, influencing selection trade-offs. The saturation versus relationship affects the ratio across the , ideally providing moderate differentials (e.g., 2-4 for many systems) to limit work input while ensuring adequate for compact components. Low saturated vapor specific (often <0.1 m³/kg at evaporator exit) further reduces compressor displacement requirements, enhancing practicality.

Historical Development

Pre-20th Century and Early Synthetic Refrigerants

The foundational principles of mechanical refrigeration were established in the early 19th century through vapor-compression cycles utilizing as a refrigerant. In 1834, American inventor received a patent for a system that compressed and condensed ether vapor to achieve cooling, marking the first viable artificial refrigeration apparatus, though it saw limited commercial adoption due to material and efficiency constraints. Ether, a volatile organic compound synthesized from , served as an early working fluid but was flammable and posed handling risks. By the mid-19th century, ammonia (NH₃) emerged as a preferred natural refrigerant for industrial applications, prized for its high latent heat of vaporization and efficiency in compression cycles. In 1856, Australian engineer James Harrison constructed the first ammonia-based compressor for commercial beer production, enabling reliable large-scale cooling without reliance on ice harvesting. Carbon dioxide (CO₂), another natural refrigerant, was employed in systems from the 1860s, as demonstrated by Thaddeus Lowe's apparatus, offering non-flammability but requiring high pressures that challenged early equipment design. These substances dominated pre-1900 refrigeration for meat packing, brewing, and ice manufacturing, despite ammonia's toxicity and CO₂'s operational demands. Sulfur dioxide (SO₂) gained traction as an early synthetic refrigerant in the 1870s, introduced by Ferdinand Carré and others for its moderate pressure requirements and corrosive properties that necessitated robust materials like steel. Used in small-scale domestic units by the late 1800s, SO₂ provided effective cooling but released irritating fumes upon leaks, contributing to safety incidents. Methyl chloride (CH₃Cl), a halogenated synthetic compound, was adopted around the same period for its low boiling point and refrigerant properties, appearing in systems from the 1870s onward and becoming common in early 20th-century household refrigerators until 1929. Both SO₂ and methyl chloride represented transitional synthetics—less flammable than ether but highly toxic and prone to explosions or poisoning—driving demand for safer alternatives amid growing domestic use. Their prevalence highlighted trade-offs in early refrigerant selection, prioritizing thermodynamic performance over human safety.

Rise of CFCs and Ozone Depletion Discovery

In the late 1920s, refrigeration systems commonly employed toxic and flammable substances such as ammonia, sulfur dioxide, and methyl chloride, which caused numerous accidents, including a 1929 explosion at a Cleveland hospital that killed over 100 people. To address these safety hazards, General Motors' Frigidaire division collaborated with DuPont to develop non-toxic alternatives; chemist , along with colleagues Albert Henne and Robert McNary, synthesized dichlorodifluoromethane (CCF₂, designated ) in 1928 and patented it in 1930 as a stable, inert refrigerant. Marketed by DuPont as , this chlorofluorocarbon () exhibited low boiling point (-29.8°C), non-flammability, and negligible toxicity under normal conditions, facilitating its commercial introduction in Frigidaire refrigerators in 1930. The advantages of CFCs propelled their rapid adoption: by 1935, R-12 had captured a significant share of the domestic refrigeration market, replacing hazardous fluids and enabling safer, more compact appliances. Through the 1940s and 1950s, production scaled dramatically, with additional CFCs like trichlorofluoromethane (R-11) developed for foam blowing and solvents; global CFC consumption reached millions of tons annually by the 1960s, driven by applications in automotive air conditioning (starting with Packard's 1939 system), commercial refrigeration, and emerging consumer products. By the early 1970s, CFCs accounted for over 90% of refrigerants in vapor-compression systems worldwide, supported by their thermodynamic efficiency and long-term stability, which minimized leaks and maintenance. Scientific scrutiny of CFCs intensified in the 1970s amid rising atmospheric concentrations, measured at parts-per-trillion levels by NOAA monitoring. In June 1974, chemists Mario J. Molina and F. Sherwood Rowland published a seminal paper in Nature, proposing that ultraviolet photolysis of CFCs in the stratosphere releases chlorine atoms, which catalyze ozone (O₃) destruction through a chain reaction: Cl + O₃ → ClO + O₂, followed by ClO + O → Cl + O₂, enabling a single Cl atom to deplete approximately 100,000 O₃ molecules before neutralization. Their kinetic models, grounded in laboratory rate constants and atmospheric transport data, predicted a 2-7% global ozone reduction by 1990 if emissions persisted at 1970s rates of about 0.5 million metric tons annually, primarily from refrigeration and aerosol propellants. Initial industry responses, including from DuPont, questioned the models' assumptions on stratospheric lifetimes and chlorine yields, citing uncertainties in heterogeneous chemistry and natural variability, though subsequent observations validated the core mechanism. This hypothesis, later corroborated by Antarctic ozone hole data in 1985, underscored CFCs' unintended role as persistent, anthropogenically sourced ozone-depleting substances.

HFC Adoption and Initial Climate Concerns

Following the 1987 Montreal Protocol and its amendments, which mandated the phaseout of chlorofluorocarbons (CFCs) in developed countries by 1996 due to their role in stratospheric ozone depletion, hydrofluorocarbons (HFCs) were rapidly adopted as primary replacements in refrigeration and air conditioning systems. HFCs, lacking chlorine, exhibited zero ozone depletion potential (ODP), making them compliant with the protocol's requirements while maintaining thermodynamic compatibility with existing vapor-compression infrastructure. Commercial introduction of key HFCs occurred in the early 1990s; for instance, R-134a (1,1,1,2-tetrafluoroethane) was developed and marketed starting in 1991 as a direct substitute for R-12 in automotive air conditioning, with widespread adoption by 1994 in new vehicles. This transition extended to stationary applications, where blends like R-404A and R-407C replaced HCFC-22 in commercial refrigeration and heat pumps by the late 1990s. Although HFCs addressed ozone concerns, their high global warming potentials (GWPs)—ranging from hundreds to thousands of times that of carbon dioxide over a 100-year horizon—prompted early scientific scrutiny regarding their climate impacts. For example, HFC-134a has a 100-year GWP of approximately 1,430, reflecting its strong infrared absorption and atmospheric persistence of about 14 years. Initial assessments in the 1990s, including analyses by the , highlighted that unchecked HFC emissions could contribute substantially to radiative forcing, potentially offsetting some ozone recovery benefits through enhanced greenhouse warming. Atmospheric concentrations of major HFCs began rising detectably by the early 2000s, with projections indicating they could account for up to 0.4°C of additional warming by 2100 absent mitigation. These concerns, rooted in empirical measurements of HFC radiative efficiencies and emission inventories, underscored a trade-off: while HFCs averted ozone loss, their fluorinated structure conferred potent, long-lived greenhouse effects, influencing subsequent policy debates on balancing ozone protection with climate stabilization.

Recent Phaseouts and Low-GWP Transitions

The Kigali Amendment to the Montreal Protocol, adopted in 2016 and entering into force on January 1, 2019, established a global phasedown of hydrofluorocarbon (HFC) production and consumption, targeting an 80-85% reduction by 2045-2047 depending on country groupings, with developed nations beginning reductions in 2019 and Article 5 countries (developing nations) starting freezes in 2024 and phasedowns in 2028 or 2029. By September 2025, 168 states and the European Union had ratified it, though implementation varies, with atmospheric HFC concentrations continuing to rise albeit at slowing rates due to early actions in some regions. In the United States, the American Innovation and Manufacturing (AIM) Act of 2020 directs the Environmental Protection Agency (EPA) to phase down HFC production and consumption to 15% of the 2011-2013 baseline by 2036 through an 85% reduction in allocated allowances, with stepwise cuts beginning in 2022: 90% of baseline allowed through 2023, dropping to 60% in 2024-2028, 40% in 2029-2033, 20% in 2034-2035, and 15% thereafter. This includes sector-specific restrictions, such as prohibitions on high-GWP HFCs like R-404A and R-507A in new commercial refrigeration from January 1, 2025, and in new cold storage from 2026, prompting retrofits and equipment redesigns. The European Union updated its F-gas Regulation in 2024 (Regulation (EU) 2024/573, effective March 11, 2024), enforcing an HFC phasedown via quotas that achieve a 79% reduction from the 2009-2012 baseline by 2030 and a full phase-out by 2050, with immediate bans on virgin HFCs exceeding 2500 GWP in small refrigeration systems from 2025 and production caps at 60% of 2011-2013 levels starting the same year. These measures build on earlier quotas since 2015, targeting sectors like stationary refrigeration and air conditioning, where HFCs comprised over 90% of F-gas emissions in 2022. Transitions to low-GWP alternatives (typically <150 GWP) include hydrofluoroolefins (HFOs) such as R-1234yf (GWP 4) for mobile air conditioning, replacing R-134a (GWP 1430), and blends like R-448A (GWP 1387, but lower than R-404A's 3922) for commercial refrigeration retrofits. Natural refrigerants are gaining traction: carbon dioxide (R-744, GWP 1) in cascade systems for supermarkets, achieving efficiency comparable to HFCs with lower total equivalent warming impact when leaks are minimized; propane (R-290, GWP 3) in small hermetic systems under 150g charge for domestic appliances; and ammonia (R-717, GWP 0) in industrial settings despite toxicity constraints. However, these shifts face empirical challenges: mildly flammable A2L HFOs and highly flammable A3 naturals like R-290 require redesigned components, enhanced leak detection, and updated safety codes (e.g., UL 60335-2-40 standards), increasing upfront costs by 20-50% for systems and risking higher fire hazards if not managed, as evidenced by lab tests showing ignition energies lower than traditional refrigerants. Efficiency losses in some low-GWP options, such as 5-10% lower coefficient of performance for certain HFO blends versus HFCs, can elevate indirect emissions from energy use, underscoring that lifecycle assessments—factoring leaks (up to 15% annually in some systems) and operational efficiency—are critical beyond direct GWP metrics. Regulatory timelines have also strained supply chains, with HFC prices surging 200-300% in the US by 2024 due to allowance reductions.

Desirable Properties and Selection Criteria

Efficiency and Performance Metrics

The coefficient of performance (COP) serves as the primary metric for evaluating refrigerant efficiency in vapor-compression cycles, calculated as the ratio of net refrigerating effect (enthalpy difference across the evaporator) to compressor work input (enthalpy difference across the compressor). Higher COP values indicate better thermodynamic efficiency, typically ranging from 2 to 6 depending on operating conditions like evaporator and condenser temperatures. Volumetric cooling capacity, another key metric, quantifies the refrigerant's ability to provide cooling per unit volume of compressor displacement, influenced by vapor density and latent heat of vaporization; it determines required compressor size and indirectly affects system cost and efficiency. Refrigerant selection impacts these metrics through properties such as critical temperature, pressure-temperature behavior, and heat transfer characteristics, which affect cycle deviations from the ideal reversed Carnot cycle. For instance, refrigerants with boiling points closer to application temperatures minimize compression ratios and irreversibilities, enhancing COP. In practice, low-global-warming-potential (GWP) alternatives often exhibit trade-offs: while some match or exceed hydrofluorocarbon (HFC) COP, others require system redesigns that reduce capacity by 5-20%, necessitating larger components and potentially offsetting efficiency gains. Comparative studies highlight variations across refrigerant classes. In automotive vapor-compression systems, R1234yf (an HFO replacement for R134a) delivers a COP up to 2.7% lower and capacity up to 4% lower at standard test conditions (evaporator 0°C, condenser 40°C). For residential air conditioning, R32 achieves a COP 3.1% higher than R410A in ground-source heat pumps, with 35% lower mass flow rates due to higher volumetric capacity, though flammability requires safety adaptations. Natural refrigerants like R290 (propane) and R744 (CO2) often yield superior COP—R290 within 13% of top HFCs and sometimes higher, while R744 systems show 27.5% higher annual COP than R134a equivalents in certain low-temperature applications, albeit with higher discharge pressures demanding robust components.
RefrigerantBaseline ComparisonCOP Relative DifferenceCapacity NotesSource
R1234yf vs. R134aAutomotive bench tests-2.7%-4% volumetric
R32 vs. R410AGround-source heat pumps+3.1%Higher volumetric, lower mass flow
R744 vs. R134aAnnual system operation+27.5%Higher system weight offsets some gains
R290 vs. HFCsOptimized systemsComparable or higher (top tier)High efficiency, flammability limits
Actual performance deviates from theoretical values due to real-world factors like heat exchanger fouling, lubricant interactions, and non-ideal compression, often reducing COP by 10-20% below ideal predictions. Blends, such as HFO/HFC mixtures, can fine-tune metrics—for example, certain R134a replacements show only 1.5% COP reduction while maintaining capacity—but require empirical validation to account for zeotropic behavior and glide effects. Overall, while regulatory drives toward low-GWP options prioritize environmental metrics over pure efficiency, empirical data underscore that hydrocarbons and select HFOs can sustain or improve performance without disproportionate penalties.

Safety and Compatibility Factors

ASHRAE Standard 34 establishes safety classifications for refrigerants based on toxicity and flammability, assigning each a designation such as A1 (lower toxicity, nonflammable) or B2L (higher toxicity, low flammability). Toxicity classes distinguish lower chronic toxicity (A, occupational exposure limit ≥400 ppm) from higher (B, <400 ppm), derived from empirical data on acute and chronic effects including cardiac sensitization and asphyxiation risks. Flammability subclasses range from 1 (no flame propagation) to 3 (highly flammable), with 2L indicating mildly flammable refrigerants like HFOs exhibiting lower heat of combustion (<19 kJ/g) and slower burning velocities (<10 cm/s). Toxicity hazards primarily involve inhalation exposure leading to oxygen displacement or direct physiological effects; for instance, refrigerant concentration limits (RCLs) are calculated from acute toxicity exposure limits (ATELs) based on LC50 data from rodent studies, ensuring concentrations below observed lethal thresholds. Ammonia (R-717, B2) exemplifies higher toxicity with an OEL of 25 ppm due to irritant effects on respiratory tissues, while hydrofluorocarbons like R-134a (A1) show minimal acute toxicity at typical exposure levels but can sensitize the heart to catecholamines at concentrations exceeding 10,000 ppm. Empirical field data from leak incidents indicate rare but severe outcomes, such as asphyxiation in confined spaces, prompting standards like ANSI/ASHRAE 15 to mandate ventilation and leak detection. Flammability poses ignition risks in leaks, particularly for A2L/A3 classes; hydrocarbons like propane (R-290, A3) have autoignition temperatures around 470°C and can propagate flames rapidly in air mixtures of 2.1-9.5% volume, though quantitative risk assessments show low probability of sustained fires in properly designed systems due to limited charge sizes. Mildly flammable A2L refrigerants, such as R-32 or R-1234yf, require mitigation like charge limits (<150 g in small appliances per ISO 5149) and sensors, as burning velocities below 10 cm/s reduce fire spread compared to A3 counterparts. High-pressure refrigerants like CO2 (R-744, A1) present explosion risks from vessel rupture, with critical pressures exceeding 73 bar necessitating robust materials. Compatibility factors influence system longevity, as refrigerants interact with lubricants, elastomers, and metals; HFCs demand polyolester (POE) oils for miscibility, unlike CFC-compatible mineral oils, with incompatibility leading to oil return failures and compressor wear observed in retrofit tests. HFOs like R-1234yf exhibit swelling or degradation in certain elastomers (e.g., chloroprene rubber volume increase >20% after 168-hour exposure at 100°C), requiring fluorocarbon-compatible to prevent leaks. risks arise with trace contaminants; for example, HFC blends can form acids with , attacking alloys, as evidenced by empirical weight loss data in accelerated aging studies showing >0.1 mm/year pitting in aluminum. Material selection thus prioritizes empirical compatibility charts from AHRI testing, ensuring stability across operating temperatures from -40°C to 150°C.
RefrigerantSafety ClassKey Hazard Notes
R-134aA1Nonflammable; low , cardiac >30,000 .
R-32A2LMildly flammable (burning velocity 6.7 cm/s); OEL 1000 .
R-717 (NH3)B2Flammable; high (OEL 25 ), irritant.
R-290A3Highly flammable; low but ignition in 2-10% mixtures.
R-744 (CO2)A1Nonflammable; asphyxiant at >5% volume displacement.

Environmental Assessment: ODP vs. GWP

The (ODP) quantifies a substance's capacity to destroy stratospheric relative to an equivalent mass of CFC-11, which is assigned an ODP of 1.0; values are derived from laboratory measurements of or release , atmospheric modeling of to the stratosphere, and empirical observations of loss rates. For refrigerants, chlorofluorocarbons (CFCs) like CFC-12 exhibit ODPs near 1.0, hydrochlorofluorocarbons (HCFCs) such as HCFC-22 have ODPs around 0.05, while hydrofluorocarbons (HFCs) possess negligible ODPs (effectively 0) due to the absence of or atoms capable of catalytic destruction cycles. In contrast, Global Warming Potential (GWP) measures the integrated radiative forcing of a substance's emissions over a specified time horizon—typically 100 years for policy assessments—relative to carbon dioxide (CO2), which has a GWP of 1 by definition; calculations incorporate infrared absorption spectra, atmospheric lifetimes, and indirect effects like stratospheric cooling, often using values from IPCC assessments such as the Fourth (2007) or Sixth (2021) reports. Refrigerants generally show high GWPs due to strong greenhouse gas properties: CFCs range from 4,600 (CFC-11) to 10,900 (CFC-12), HCFCs like HCFC-22 at 1,810, and HFCs from 130 (HFC-152a) to 12,400 (HFC-23), though newer hydrofluoroolefins (HFOs) achieve GWPs below 1. ODP and GWP address distinct environmental mechanisms—ozone depletion as a localized stratospheric versus global warming as tropospheric heat trapping—leading to historical selection tradeoffs in refrigerants: the 1987 prioritized zero-ODP HFCs to repair the , empirically reducing atmospheric ODS levels by over 99% since peak in the , but inadvertently elevated refrigeration sector emissions with GWPs thousands of times CO2, contributing 2-3% of total anthropogenic by 2010. This shift amplified climate impacts, as HFC lifetimes (1-270 years) sustain forcing longer than their ozone-neutral benefit, prompting the 2016 to phase down high-GWP HFCs by 80-85% by 2047, favoring alternatives with both low ODP and GWP under 700 for many applications. Empirical data confirm declining HCFC trends post-phaseout alongside rising then stabilizing HFC concentrations, underscoring the need for integrated metrics beyond isolated potentials, including leak rates and to minimize total lifecycle emissions.
RefrigerantTypeODP100-Year GWP
CFC-111.04,660
CFC-121.010,200
HCFC-22HCFC0.0551,760
HFC-134aHFC01,430
HFO-1234yfHFO0<1
ODP and GWP values vary slightly across assessments due to updated lifetimes and spectra, but both metrics rely on validated models corroborated by satellite and ground-based observations of ozone recovery (e.g., 20% Antarctic hole reduction since 2000) and rising HFC forcings (0.5% of total CO2-equivalent emissions in 2020). Selection now emphasizes causal chains: zero-ODP alone insufficient without low-GWP to avoid transferring ozone benefits to climate costs, as evidenced by HFC-driven warming equivalent to 0.5 GtCO2/year pre-Kigali.

Classification and Nomenclature

R-Numbering System and ASHRAE Standards

The R-numbering system provides a standardized nomenclature for refrigerants, assigning a unique identifier prefixed by "R-" followed by a numeric code, with optional suffixes for isomers or specific formulations, as defined in ANSI/ASHRAE Standard 34. This system originated from early industrial conventions for halogenated hydrocarbons but was formalized and expanded by ASHRAE to encompass a broader range of compounds, including natural refrigerants, hydrocarbons, and blends, ensuring consistent global reference without reliance on lengthy chemical names. ASHRAE assigns new numbers sequentially upon submission and verification of a refrigerant's properties, prioritizing safety data and chemical stability, with updates published periodically to reflect emerging substances. For fluorinated hydrocarbons (such as CFCs, HCFCs, and HFCs), the numeric code derives systematically from molecular composition: the first digit represents the number of carbon atoms minus one, the second digit is the number of hydrogen atoms plus one, and the third digit indicates the number of fluorine atoms, with chlorine atoms inferred from valence requirements (total halogens = 2C + 2 - H - F). Lowercase letters (e.g., "a", "b") suffix the number to distinguish isomers with identical atom counts but different spatial arrangements, as in R-134a (1,1,1,2-tetrafluoroethane). Non-fluorinated or inorganic refrigerants receive arbitrary sequential assignments outside this formula, such as R-717 for ammonia (NH₃), R-744 for carbon dioxide (CO₂), and R-718 for water (H₂O), reflecting their distinct chemical families rather than atomic substitution patterns. Unsaturated compounds use a leading "1" (e.g., 1100 series for olefins), while cyclic structures incorporate prefixes like "c-" for cycloalkanes. Refrigerant blends are designated in the 400 series for zeotropic mixtures (non-azeotropic, with temperature glide during phase change) or 500 series for azeotropic mixtures (behaving as single substances), suffixed by capital letters (A, B, etc.) to denote specific component ratios by mass percentage, as in R-410A (a near-azeotropic blend of difluoromethane and pentafluoroethane). Standard 34 mandates detailed composition disclosure for blends to enable safety assessments and performance predictions, prohibiting undisclosed or proprietary formulations in official listings. ASHRAE Standard 34 also establishes safety classifications integral to the numbering system, grouping refrigerants by toxicity (A for lower toxicity, based on 400 ppm LC50 threshold; B for higher) and flammability (1 for nonflammable; 2L for mildly flammable with low burning velocity <10 cm/s; 2 for flammable; 3 for highly flammable). These classifications, denoted as alphanumeric codes (e.g., A1 for , indicating low toxicity and nonflammability), inform engineering applications under complementary standards like ASHRAE 15 (Safety Standard for Refrigeration Systems), which set charge limits and ventilation requirements based on the designated group. Updates to designations and classifications occur via ASHRAE committee reviews, incorporating empirical toxicity and flammability test data, with recent revisions (e.g., 2022 addenda) addressing low-GWP alternatives like HFOs. This framework ensures interoperability across industries while prioritizing verifiable hazard metrics over unsubstantiated assumptions.

Chemical Families and Structures

Refrigerants are classified into chemical families based on their molecular composition, which influences phase-change behavior, stability, and reactivity. Synthetic halogenated hydrocarbons dominate historical and modern applications due to tunable boiling points from varying fluorine and chlorine substitutions on carbon backbones, typically methane (one C), ethane (two C), or propane (three C) series. These families include , , , and , distinguished by the presence or absence of hydrogen and chlorine atoms. Chlorofluorocarbons (CFCs) consist exclusively of carbon, chlorine, and fluorine, with no hydrogen, resulting in high thermal and chemical stability. Common examples include R-11 (trichlorofluoromethane, CCl₃F) and R-12 (dichlorodifluoromethane, CCl₂F₂), where the central carbon is tetrahedrally bonded to chlorine and fluorine atoms in saturated structures. This lack of hydrogen prevents hydrogen abstraction in atmospheric reactions, contributing to longevity but also ozone-depleting persistence. Hydrochlorofluorocarbons (HCFCs) incorporate hydrogen alongside chlorine, fluorine, and carbon, partially replacing chlorines in CFC structures to moderate stability. R-22 (chlorodifluoromethane, CHClF₂) features a methane backbone with one hydrogen, one chlorine, and two fluorines. The hydrogen enables slower atmospheric degradation compared to CFCs, reducing but not eliminating ozone depletion potential. Hydrofluorocarbons (HFCs) exclude chlorine, using only hydrogen, fluorine, and carbon for ozone-neutral profiles, with structures like (1,1,1,2-tetrafluoroethane, CF₃CH₂F), an ethane chain where one carbon bears three fluorines and a hydrogen, the other two fluorines and two hydrogens. Saturation provides non-flammability in many cases, though global warming potential arises from strong C-F bonds resisting breakdown. Hydrofluoroolefins (HFOs) extend HFCs with carbon-carbon double bonds, enhancing atmospheric reactivity for lower persistence. R-1234yf (2,3,3,3-tetrafluoropropene, CF₃CF=CH₂) has a propene structure with the double bond between carbons 1 and 2, fluorines clustered on carbon 3. This unsaturation promotes rapid hydrolysis or reaction with hydroxyl radicals, yielding short lifetimes.
FamilyCompositionExampleFormulaKey Structural Feature
CFCsC, Cl, FR-12CCl₂F₂Saturated, fully halogenated methane
HCFCsC, H, Cl, FR-22CHClF₂Saturated methane with partial H substitution
HFCsC, H, FR-134aCF₃CH₂FSaturated ethane, chlorine-free
HFOsC, H, FR-1234yfCF₃CF=CH₂Unsaturated propene with double bond
Non-halogenated families include hydrocarbons (HCs), such as propane (R-290, C₃H₈), a straight-chain alkane with high flammability from C-H bonds, and inorganics like ammonia (NH₃), a polar molecule with nitrogen-hydrogen bonds enabling strong hydrogen bonding. These structures prioritize natural abundance over synthetic tunability but require safety adaptations for toxicity or ignitability.

Blends, Azeotropes, and Zeotropes

Refrigerant blends are mixtures of two or more distinct refrigerants formulated to achieve targeted performance characteristics, such as enhanced efficiency, reduced flammability, or lower global warming potential compared to single-component alternatives. These blends are essential in modern refrigeration systems, particularly as substitutes for phased-out substances under international agreements like the . Blends are categorized by their thermodynamic behavior during phase changes: azeotropic blends maintain uniform composition and temperature across liquid and vapor phases, while zeotropic blends exhibit composition shifts and temperature variations. Azeotropic blends evaporate and condense at a single, constant temperature without temperature glide, mimicking the behavior of pure refrigerants. This property arises from the mixture's equilibrium where the vapor and liquid phases have identical compositions, preventing fractionation during boiling or condensation. The American Society of Heating, Refrigerating and Air-Conditioning Engineers () assigns azeotropic blends numbers in the R-500 series, such as R-502 (a binary mixture of chlorodifluoromethane () and chloropentafluoroethane () in a 48.8%/51.2% mass ratio, historically used for low-temperature commercial refrigeration until its phaseout due to ozone depletion). Other examples include R-500 (a blend of dichlorodifluoromethane () and difluoromethane ()) and R-507 (pentafluoroethane () and 1,1,1-trifluoroethane () in near-equal proportions), which offer improved capacity in medium- and low-temperature applications. Azeotropes simplify system design and charging, as they can be handled similarly to single fluids without composition drift from leaks or improper addition. Zeotropic blends, designated by ASHRAE in the R-400 series, demonstrate a temperature glide—the difference between the bubble point (start of boiling) and dew point (end of boiling) at constant pressure—due to varying volatilities of components, resulting in progressive composition changes during phase transitions. This glide, typically 0.5–10°C for common blends, can enhance heat transfer efficiency in certain evaporator designs by maintaining a closer match to load temperature profiles but requires liquid charging to minimize fractionation and performance loss. For instance, R-407C (R-32/R-125/R-134a in 23%/25%/52% mass ratios) serves as a retrofit for R-22 in air conditioning, exhibiting a 6–7°C glide that necessitates system adjustments for optimal operation. Similarly, R-404A (R-125/R-143a/R-134a at 44%/52%/4%) was widely used in commercial refrigeration before HFC phase-downs, though its significant glide (around 1.5°C) and high GWP prompted transitions to lower-impact alternatives. Zeotropic behavior demands careful purity control per standards like AHRI 700, as contaminants or improper blending can exacerbate fractionation risks during leaks or servicing. The distinction influences safety classifications under ASHRAE Standard 34, where blends are evaluated for toxicity and flammability under both nominal and fractionated compositions to account for worst-case scenarios in zeotropes. While azeotropes offer handling simplicity, zeotropes enable finer tuning of properties like glide for energy savings, as demonstrated in studies showing up to 5–10% efficiency gains in heat pumps with optimized mixtures. Empirical data from NIST confirms that zeotropic fractionation alters pressure-temperature profiles predictably but underscores the need for composition-specific glide calculations in system modeling.

Types of Refrigerants

Natural Refrigerants

Natural refrigerants are working fluids derived from naturally occurring substances, such as , , and hydrocarbons, which participate in Earth's chemical and biological cycles without anthropogenic synthesis. These refrigerants exhibit zero ozone depletion potential (ODP) and global warming potentials (GWP) typically below 5 on a 100-year time horizon, far lower than synthetic hydrofluorocarbons (HFCs) with GWPs exceeding 1000 in many cases. Their adoption has accelerated since the early 2010s amid HFC phaseouts under the 's , driven by empirical evidence of synthetic refrigerants' contributions to radiative forcing. Ammonia (R-717, NH₃) has been utilized as a refrigerant since the 1870s in industrial vapor-compression systems, offering volumetric cooling capacities up to 50% higher than HFCs like R-134a under equivalent conditions, which translates to superior thermodynamic efficiency with coefficients of performance (COP) often exceeding 4 in large-scale applications. It is non-flammable and decomposes into nitrogen and water upon atmospheric release, yielding a GWP of 0, but its acute toxicity (IDLH concentration of 300 ppm) and corrosivity to copper necessitate stainless steel components and leak detection systems compliant with ASHRAE Standard 15 safety classifications (B2L). Low-charge ammonia systems, developed since the 1990s, minimize inventory to under 100 kg in facilities, reducing leak risks while maintaining energy savings of 10-20% over HFC alternatives in food processing and cold storage. Carbon dioxide (R-744, CO₂) operates in transcritical cycles above its critical point (31.1°C, 73.8 bar), enabling heat rejection via gas cooling rather than condensation, with applications expanding in supermarket refrigeration since the late 1990s. These systems achieve COPs competitive with HFC blends in warm climates when enhanced by parallel compression or ejectors, reducing energy use by up to 15% compared to R-404A baselines in empirical field tests. Non-toxic and non-flammable (ASHRAE A1 classification), CO₂ requires high-pressure components rated to 130 bar, but its GWP of 1 aligns with lifecycle emissions data showing 30-50% lower total equivalent warming impact than HFCs when accounting for direct and indirect effects. Deployment has grown, with over 10,000 transcritical CO₂ installations in Europe by 2020 for retail cascade systems. Hydrocarbons, including propane (R-290, C₃H₈) and isobutane (R-600a, (CH₃)₃CH), serve as drop-in alternatives in small-scale appliances, with R-600a predominant in household refrigerators since EPA approval in 2012 for charges up to 57 g per unit. These exhibit GWPs of 3 and excellent miscibility with mineral oils, yielding 5-10% higher efficiency than R-134a in domestic cycles due to closer boiling points to application temperatures. Highly flammable (ASHRAE A3 classification), their use mandates charge limits under IEC 60335-2-24 standards (e.g., 150 g for R-290 in split air conditioners) and spark-proof designs, yet global adoption exceeds 200 million units annually with incident rates below 1 per million from manufacturing leaks. Propane finds niche in commercial display cases, where its lower viscosity enhances heat transfer. Despite safety challenges, natural refrigerants' empirical performance data—evidenced by reduced total emissions in monitored installations—supports their viability over synthetics, though system design must prioritize containment to mitigate hazards like ammonia's LC50 of 2455 ppm in rats or hydrocarbons' autoignition energy of 0.25 mJ. Ongoing research focuses on hybrid systems combining these fluids for optimized safety and efficiency.

Hydrofluorocarbons and Hydrofluoroolefins

Hydrofluorocarbons (HFCs) are fluorinated hydrocarbons containing only hydrogen, fluorine, and carbon atoms, engineered as drop-in replacements for ozone-depleting substances in refrigeration and air conditioning applications. Developed in the late 1980s and commercialized in the early 1990s amid the phase-out of chlorofluorocarbons (CFCs) under the , HFCs possess zero ozone depletion potential (ODP) because they lack chlorine, addressing stratospheric ozone breakdown mechanisms observed empirically through satellite and ground-based measurements. However, their saturated molecular structures confer high global warming potentials (GWPs), with 100-year GWPs ranging from 124 for difluoromethane (HFC-32) to 14,800 for trifluoromethane (HFC-23), as calculated in the IPCC's Fourth Assessment Report based on radiative forcing models and atmospheric lifetime data. Common HFCs include R-134a (1,1,1,2-tetrafluoroethane, GWP 1,430), dominant in motor vehicle air conditioning (MVAC) systems since 1994, and R-410A (a zeotropic blend of HFC-32 and HFC-125, GWP 2,088), prevalent in stationary air conditioning units for its non-ozone-depleting efficiency and moderate pressure characteristics. Atmospheric monitoring reveals steadily rising HFC concentrations, driven by emissions from equipment leaks, servicing, and end-of-life disposal; for example, global HFC-134a mole fractions increased from near-zero in the 1990s to approximately 100 parts per trillion by the 2020s, reflecting empirical trends captured by networks like NOAA's Global Monitoring Laboratory. Collectively, HFCs accounted for 1.27% of the total radiative forcing from anthropogenic greenhouse gases in 2022, a minor but growing fraction compared to CO2's dominance, with emissions inferred from inverse modeling of observed abundances showing acceleration in regions like East Asia until recent regulatory interventions. Hydrofluoroolefins (HFOs) represent a newer class of unsaturated fluorocarbons, distinguished by at least one carbon-carbon double bond that enhances atmospheric reactivity and shortens lifetimes to days or weeks, yielding GWPs typically under 1—far below HFCs—while preserving zero ODP. Introduced in the mid-2000s by chemical manufacturers like Honeywell and Chemours as HFC successors, HFOs address high-GWP critiques through molecular design prioritizing rapid photodegradation over persistence, with examples including HFO-1234yf (2,3,3,3-tetrafluoropropene, GWP <1), adopted in European automotive air conditioning from 2011 onward for its thermodynamic compatibility with R-134a systems, and HFO-1234ze(E) (trans-1,3,3,3-tetrafluoropropene, GWP <1), used in chillers and heat pumps. These mildly flammable (ASHRAE A2L classification) refrigerants offer comparable cooling capacities but require adapted safety protocols due to lower flammability limits than hydrocarbons. Comparatively, HFOs exhibit reduced direct climate forcing versus HFCs, with lifecycle emissions analyses showing orders-of-magnitude lower 100-year integrated GWPs, though degradation pathways produce trifluoroacetic acid (TFA)—a naturally occurring but potentially accumulating pollutant in water bodies—prompting ongoing empirical studies on aquatic toxicity and persistence, as HFO-1234yf yields up to five times more TFA than equivalent HFC-134a masses under modeled atmospheric oxidation. Industry sources emphasize HFOs' net environmental benefits given short lifetimes and low emission rates in contained systems, but independent assessments highlight uncertainties in TFA bioaccumulation, underscoring the need for field data over projections.
RefrigerantDesignationChemical FormulaGWP (100-year)Primary Applications
R-134aHFCCH₂F-CF₃1,430MVAC, domestic refrigeration
R-410AHFC blend(HFC-32/HFC-125)2,088Residential/commercial AC
HFO-1234yfHFOCF₃-CF=CH₂<1Automotive AC
HFO-1234zeHFOCF₃-CH=CHF<1Chillers, foam blowing

Phased-Out and Banned Substances

Chlorofluorocarbons (CFCs) were the first major class of refrigerants targeted for phase-out and eventual ban due to their high ozone depletion potential (ODP), measured relative to CFC-11 at 1.0. The 1987 Montreal Protocol mandated a global phase-out of CFC production and consumption, with developed countries completing the elimination by January 1, 1996, and developing countries by 2010. Common CFCs included R-11 (trichlorofluoromethane), used in large chillers, and R-12 (dichlorodifluoromethane), prevalent in automotive and domestic refrigeration systems until the mid-1990s. These substances contributed significantly to stratospheric ozone loss, as evidenced by empirical measurements of Antarctic ozone holes correlating with CFC atmospheric concentrations peaking in the 1990s before declining post-phase-out. Hydrochlorofluorocarbons (HCFCs) served as interim replacements for CFCs, featuring lower ODP values (typically 0.01 to 0.1), but were themselves scheduled for phase-out under Montreal Protocol amendments due to residual ozone impacts and nontrivial global warming potential (GWP). In the United States, production and import of most HCFCs ended January 1, 2020, with servicing of existing equipment permitted using recovered or reclaimed material until 2030. R-22 (chlorodifluoromethane), with an ODP of 0.055 and GWP of approximately 1,810, dominated residential air conditioning until its production ban, accounting for over 80% of HCFC consumption in refrigeration sectors. Other notable HCFCs include R-123 (ODP 0.02), used in centrifugal chillers, and R-142b (ODP 0.065), both subject to the same timelines. The phase-out of CFCs and HCFCs has led to measurable atmospheric declines, with CFC-12 levels dropping over 50% since 1994 peaks, validating causal links between emissions bans and reduced stratospheric chlorine loading. HCFC consumption in developed nations fell ahead of schedules in some cases, such as Australia's near-complete phase-out by 2016. While hydrofluorocarbons (HFCs) replaced these without ozone depletion (ODP 0), they face phase-down rather than outright bans under the 2016 Kigali Amendment, targeting high-GWP variants like R-134a (GWP 1,430) through production caps starting 2019 in developed countries, not prohibition.
RefrigerantFamilyODPKey ApplicationsPhase-Out Milestone (Developed Countries)
R-11CFC1.0ChillersProduction banned 1996
R-12CFC1.0Auto/domestic ACProduction banned 1996
R-22HCFC0.055Residential ACProduction/import banned 2020; servicing to 2030
R-123HCFC0.02ChillersProduction/import banned 2020; servicing to 2030
R-142bHCFC0.065Blends/refrigerationProduction/import banned 2020
These timelines reflect binding international commitments, enforced domestically by agencies like the U.S. EPA, with non-compliance risking fines and trade restrictions on ODS-containing equipment. Empirical data from ground-based and satellite monitoring confirm efficacy, though illegal production in some regions has occasionally slowed declines.

Environmental Impacts

Ozone Depletion: Mechanisms and Empirical Evidence

Chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs), widely used as refrigerants until regulatory phaseouts, are chemically stable in the troposphere, allowing them to ascend to the stratosphere over years to decades. There, intense ultraviolet radiation with wavelengths shorter than 220 nm photodissociates these molecules, primarily cleaving carbon-chlorine bonds to release highly reactive chlorine atoms (Cl). These Cl atoms act as catalysts in ozone destruction cycles, with the dominant null cycle being: Cl + O₃ → ClO + O₂, followed by ClO + O → Cl + O₂, yielding a net reaction of 2O₃ → 3O₂ and regenerating the Cl atom for repeated catalysis. Each Cl atom can destroy up to 100,000 ozone molecules before forming inactive reservoirs like ClONO₂ or HCl, amplifying the impact of even trace chlorine levels. In polar regions, polar stratospheric clouds (PSCs) formed at temperatures below -78°C activate these reservoirs via heterogeneous reactions, converting them back to active Cl₂ or HOCl, which photolyze to Cl, greatly enhancing depletion during winter-spring darkness. The theoretical framework for CFC-induced ozone depletion was first detailed in 1974 by Mario Molina and F. Sherwood Rowland, who calculated that unchecked CFC emissions could reduce stratospheric ozone by 30-50% over decades due to chlorine loading reaching several parts per billion by volume (ppbv). Initial empirical support emerged in the late 1970s from aircraft measurements detecting elevated stratospheric chlorine monoxide (ClO), a key intermediate in the catalytic cycle, at levels correlating with CFC photodegradation products. Ground-based Dobson spectrophotometer observations at Halley Bay, Antarctica, revealed unprecedented springtime ozone declines starting in the early 1980s, culminating in the 1985 identification of the "ozone hole," where total column ozone fell below 220 Dobson units (DU)—a 40-60% reduction from pre-1970s norms of 300-350 DU. Satellite data from NASA's Total Ozone Mapping Spectrometer confirmed the hole's seasonal extent, covering up to 25 million km² by the 1990s, coinciding with peak stratospheric chlorine concentrations of approximately 3.7 ppbv around 1993-1995. Direct causal linkage was established through concurrent measurements: balloon-borne and aircraft campaigns in the 1980s-1990s quantified ClO enhancements up to 1 ppbv inside the vortex, with anticorrelation to ozone partial pressures, and isotopic analysis ruling out natural chlorine sources like sea salt. Model simulations incorporating observed chlorine trends reproduced the hole's morphology only when including heterogeneous PSC chemistry, while excluding it failed to match depletions exceeding 5-6 ppmv per day. Post-1987 Montreal Protocol phaseouts of CFCs reduced effective stratospheric chlorine by 0.8% annually from 2005 onward, correlating with a 20% decrease in chemical ozone loss rates over Antarctica and a 25 ppt/yr decline in lower stratospheric Cl_y (total inorganic chlorine). By 2020-2022, the Antarctic ozone hole's maximum area had shrunk by 10-15% compared to 2000 peaks, with upper stratospheric ozone increasing 1-3% per decade, consistent with declining ODS abundances rather than dynamical variability alone. HCFCs, transitional refrigerants with lower ozone depletion potentials (ODP 0.01-0.1 vs. CFCs' 0.6-1.0), continue minor contributions but are projected to peak and decline under the Protocol, supporting ongoing recovery to pre-1980 levels by mid-century.

Global Warming Contributions: Measured Emissions Data

Hydrofluorocarbons (HFCs), widely used as refrigerants, contribute to global warming through direct atmospheric emissions primarily from leaks in refrigeration and air conditioning systems. Measured emissions are estimated using top-down approaches, such as atmospheric observations from networks like NOAA and AGAGE, combined with inverse modeling to infer release rates. Global HFC emissions reached approximately 0.88 ± 0.07 gigatonnes of CO₂ equivalent (GtCO₂-eq) per year as of recent assessments, representing about 1.5-2% of total anthropogenic greenhouse gas emissions. Atmospheric concentrations of key HFCs, including HFC-134a, HFC-125, and HFC-32, have shown sustained increases, with annual growth rates for HFC-125 at 4.8 parts per trillion (ppt) per year and for HFC-32 at 7.9 ppt per year through the early 2020s. These trends reflect rising emissions, particularly in East Asia, where HFC contributions to the global total grew from 9% (2008-2014) to 13% (2016-2020), driven by sharp accelerations in China and Japan around 2016-2018. In contrast, global HFC-23 emissions, a byproduct of HCFC-22 production, declined to 14.0 ± 0.9 Gg per year by 2023 due to targeted destruction efforts. In the United States, fluorinated gas emissions, dominated by HFCs from refrigeration and foam blowing, increased 105% from 1990 to 2022, totaling around 150 million metric tons CO₂-eq annually by the latter year. Globally, total HFC emissions in CO₂-equivalent terms continued rising through 2019 per NOAA-derived observations, though phase-down commitments under the have begun moderating growth in some regions. These measurements underscore that while HFC emissions remain a minor fraction compared to CO₂, their high global warming potentials—ranging from hundreds to thousands of times that of CO₂—amplify their radiative forcing impact.

Lifecycle Analysis and Comparative Risks

Lifecycle assessments of refrigerants evaluate environmental burdens from raw material extraction through synthesis, distribution, system integration, operational use (including leakage rates typically ranging from 5-15% annually in commercial systems), maintenance, decommissioning, recovery, recycling, and disposal or destruction. The Total Equivalent Warming Impact (TEWI) framework integrates direct greenhouse gas emissions—weighted by global warming potential (GWP)—with indirect emissions from the energy inefficiency of refrigeration cycles, where operational leaks often dominate total impacts, contributing 70-90% of lifecycle emissions for high-GWP hydrofluorocarbons (HFCs). Production phases for fluorinated refrigerants, involving fluorspar mining and energy-intensive fluorination, add 2-10% to overall TEWI depending on facility efficiency and electricity sources, while natural refrigerants like ammonia or carbon dioxide incur lower synthesis emissions due to simpler derivation from industrial byproducts. Comparative TEWI analyses reveal context-dependent advantages: in supermarket refrigeration, transcritical CO2 systems yield 20-40% lower TEWI than HFC-507A blends over 20-year lifecycles, driven by CO2's GWP of 1 versus HFC-507A's 3980, despite CO2's reduced coefficient of performance in warm climates necessitating auxiliary energy. Hydrocarbon refrigerants (e.g., propane) exhibit even lower TEWI in small-scale or transport applications—up to 50% below HFC-R134a—owing to zero GWP and high thermodynamic efficiency, though end-of-life recovery challenges persist with global rates below 30% for many systems due to venting during disposal. Hydrofluoroolefins (HFOs), such as R1234yf with GWP <1, reduce direct emissions but show comparable or slightly higher TEWI in automotive applications when factoring 10-20% leakage and minor efficiency penalties versus HFC-134a. Beyond climate metrics, comparative risks encompass safety tradeoffs: HFCs and HFOs classify as low-toxicity, nonflammable (ASHRAE A1/A2L), minimizing acute hazards during leaks, whereas ammonia (B2) poses severe inhalation risks requiring specialized handling, and hydrocarbons (A3) elevate fire ignition probabilities in enclosed spaces despite lower explosion energies. Ozone depletion risks are negligible across modern options post-, as HFCs and HFOs have zero ODP, unlike phased-out hydrochlorofluorocarbons (HCFCs). Empirical data from NIST assessments underscore these complexities, noting that while low-GWP alternatives curb atmospheric warming, their deployment demands engineering mitigations—e.g., charge limits for flammables—that can increase upfront costs by 10-30% without proportionally reducing total lifecycle hazards. Disposal-phase risks amplify for unrecovered HFCs, where atmospheric release equivalents exceed production emissions by orders of magnitude, prompting lifecycle management strategies like destruction via plasma arc to achieve >99% abatement.

Regulations and Policy Debates

International Treaties: Montreal Protocol and Kigali Amendment

The on Substances that Deplete the , adopted on September 16, 1987, in , , and entering into force on January 1, 1989, establishes a framework for phasing out the production and consumption of ozone-depleting substances (ODS), including chlorofluorocarbons (CFCs) such as R-12 and R-11, which were predominant refrigerants in the late . The treaty initially called for a 50% reduction in CFC consumption by 1998 for developed countries, with subsequent amendments in (1990) and (1992) accelerating timelines to full phase-out of CFCs by January 1, 1996, for Article 2 parties (developed nations) and by 2010 for Article 5 parties (developing nations). Hydrochlorofluorocarbons (HCFCs), such as R-22, served as transitional refrigerants but faced phase-out schedules adjusted in 2007 to complete elimination by 2030 in developed countries and 2040 in developing ones, reflecting their lower but non-zero . As of 2024, the protocol has achieved universal ratification by all 198 UN member states, enabling near-global compliance through trade restrictions on non-parties and financial mechanisms like the Multilateral Fund, which has disbursed over $3.8 billion to support developing countries. Empirical measurements confirm the protocol's impact on ODS levels: atmospheric concentrations of key CFCs peaked in the early 1990s and have declined by over 99% from production highs, correlating with reduced stratospheric loading and early signs of recovery, including a 20% increase in since 2000. However, legacy emissions from banks of existing equipment continue to contribute to residual depletion, with full recovery projected for 2066 globally and later in polar regions. The Kigali Amendment, adopted on October 15, 2016, during the 28th Meeting of the Parties in Kigali, Rwanda, and entering into force on January 1, 2019, for ratifying states, addresses hydrofluorocarbons (HFCs)—non-ozone-depleting substitutes for ODS like R-134a and R-410A used in refrigeration and air conditioning—by mandating a global phasedown of their production and consumption due to their high global warming potentials (GWPs) ranging from hundreds to thousands of times that of CO2. Unlike the original protocol's focus on ozone depletion, Kigali targets climate forcing from HFCs, which had risen sharply post-Montreal as ODS replacements; the amendment establishes baselines using 2011-2013 averages (or 2020-2022 for some late joiners) and requires developed countries to freeze consumption in 2019 and reduce to 80% of baseline by 2036, 50% by 2045, and lower thereafter. Developing countries are divided into two groups: Group 1 (e.g., China, India) freezes in 2024 and achieves 80% reduction by 2047; Group 2 (e.g., several Middle Eastern and African nations) freezes in 2028 with similar long-term cuts. Projections estimate the amendment will avert up to 105 billion tonnes of CO2-equivalent emissions by 2050, potentially avoiding 0.3–0.5°C of warming by 2100, though early implementation data indicate uneven HFC-23 byproduct emissions reductions. As of September 2024, 168 states plus the European Union have ratified, covering over 90% of global HFC consumption.

Domestic Policies: US AIM Act and EPA Rules

The American Innovation and Manufacturing (AIM) Act of 2020, enacted on December 27, 2020, as Division S of the , establishes the principal U.S. framework for curtailing (HFC) production and consumption. The grants the (EPA) authority across three domains: phasedown of HFC production and consumption by 85% by 2036 from a 2011–2013 baseline, sector-specific restrictions to accelerate adoption of lower (GWP) substitutes, and mandatory emissions management via reclamation, destruction, and reporting. This domestic approach implements the HFC reduction commitments of the to the without requiring U.S. ratification of the international accord. The phasedown initiated on January 1, 2022, with EPA allocating production and consumption allowances annually to regulated entities, enforced through tracking and surrender requirements. Statutory schedules mandate progressive cuts—reaching a 70% reduction by 2029—via baseline adjustments and penalties for non-compliance, including fines up to $50,000 per violation per day. Importers and producers must petition for essential-use exemptions, limited to applications lacking viable alternatives. EPA's Technology Transitions Rule, finalized October 24, 2023, leverages the Act's restriction authority to ban HFCs exceeding GWP thresholds (typically >700–1500, varying by sector) in newly manufactured or imported equipment. Key prohibitions include: high-GWP HFCs in chillers effective January 1, 2024; commercial refrigerators and warehouses from January 1, 2025; systems and vending machines from January 1, 2026; and systems phased in through 2028, with extensions for permitted installations. These apply to sectors like , , foams, and aerosols, exempting existing equipment but requiring certification of compliance. Complementing these, the HFC Emissions Reduction and Reclamation Program, finalized October 19, 2023, imposes leak detection and repair thresholds (e.g., 20–50% annual leak rate for refrigeration systems >50 pounds charge) and mandates 90% reclamation efficiency for serviced or decommissioned equipment. Technicians must use certified recovery equipment, with records retained for five years and reported to EPA. As of October 2025, EPA has proposed revisions to certain transition timelines in response to industry petitions citing supply chain constraints, though the overarching phasedown and core restrictions persist.

Economic Costs, Compliance Burdens, and Effectiveness Critiques

The phase-down of hydrofluorocarbons (HFCs) under the and the U.S. American Innovation and Manufacturing () Act entails substantial economic costs for producers, manufacturers, and end-users. Replacement options like hydrofluoroolefins (HFOs) command prices of $40 to $60 per pound, compared to $4 to $6 per pound for HFCs, driving up refrigerant acquisition expenses. New HVAC equipment compliant with EPA rules for low (GWP) refrigerants incurs at least a 20% increase in materials costs relative to prior models using higher-GWP substances like . In developing countries, , including HCFC phase-outs, has required investments exceeding billions in cumulative funding through the Multilateral Fund, yet total economic burdens—including retrofits and lost —often surpass provided assistance, straining local industries reliant on affordable cooling. Compliance burdens weigh heavily on the HVAC and refrigeration sectors, mandating rapid transitions to alternatives such as or R-32 with GWPs under 750 for new systems starting in 2025. Regulations apply stringently to appliances holding 15 pounds or more of refrigerant, enforcing leak rates below 30% for commercial and industrial units, with mandatory repairs or retirements for non-compliance. The Act's 85% HFC reduction by 2036 necessitates supply chain overhauls, including certification for handling mildly flammable A2L-class refrigerants, specialized recovery equipment, and technician retraining to meet purity standards for reclaimed gases. Non-adherence risks fines of up to $37,500 per violation per day, alongside disruptions from phased production allowances that limit HFC availability and inflate black-market premiums. Effectiveness critiques center on the regulations' limited net environmental gains amid enforcement gaps and overstated benefits. Illegal HFC —seizing hundreds of metric tons annually in the EU from sources like and —undermines phase-down schedules by sustaining high-GWP usage and disadvantaging rule-following firms, while contributing unchecked emissions equivalent to millions of tons of CO2. Policy analyses contend the yields marginal climate impact, as HFCs account for under 4% of projected emissions, with phase-outs imposing disproportionate U.S. economic strain without verifiable proportional reductions, given reliance on contested models valuing potent HFCs at up to $2 million per ton. In developing nations, incomplete adherence and inadequate Multilateral Fund support exacerbate leakage risks, potentially offsetting and warming benefits through inefficient alternatives or deferred maintenance, as empirical data show persistent illegal trade eroding global integrity.

Safety, Handling, and Management

Toxicity, Flammability, and ASHRAE Classifications

ASHRAE Standard 34 establishes a classification system for refrigerants based on and flammability, using empirical data from tests such as lower flammability limits (LFL), , burning velocity, and occupational limits (OEL) derived from metrics like LC50 (lethal concentration for 50% of subjects). is divided into Class A (low toxicity, OEL ≥400 , indicating minimal acute health risks at typical levels) and Class B (higher , OEL <400 ppm, associated with risks like irritation, organ damage, or lethality from inhalation). Flammability classes include 1 (no flame propagation under standard tests), 2L (mildly flammable with burning velocity <10 cm/s and lower heat release), 2 (flammable with moderate propagation), and 3 (highly flammable, rapid flame spread). These combine into safety groups (e.g., A1 for low toxicity/non-flammable, A2L for low toxicity/mildly flammable), which dictate charge limits, ventilation requirements, and mitigation under standards like 15 to minimize risks such as asphyxiation from oxygen displacement or ignition. Most hydrofluorocarbons (HFCs) and hydrofluoroolefins (HFOs), such as R-134a and R-1234yf, fall into Class A1 or A2L, exhibiting low acute toxicity with LC50 values exceeding 100,000 ppm for 4-hour rat inhalation exposures, primarily posing risks of cardiac sensitization or simple asphyxiation in high concentrations rather than direct poisoning. In contrast, ammonia (R-717, B2) demonstrates high toxicity with an LC50 of approximately 2,000 ppm for 1-hour exposure in rodents, causing severe respiratory irritation, pulmonary edema, and fatalities in industrial leaks, as evidenced by historical incidents like the 1921 Atlanta explosion killing 18 due to toxic vapor release. Carbon dioxide (R-744, A1) is non-toxic at low levels but acts as an asphyxiant, with empirical data showing neurocognitive impairment at 3-5% concentrations and unconsciousness above 10%, though its density enables pooling in confined spaces, contributing to rare but documented suffocation events in refrigeration failures. Hydrochlorofluorocarbons (HCFCs) like R-22 share A1 status with HFCs but include decomposition products under fire conditions that elevate toxicity risks. Flammability risks vary significantly across classes, with Class 1 refrigerants like R-410A showing no ignition under ASTM E681 tests at 60°C, minimizing propagation even in leaks up to system charge limits. A2L refrigerants, such as R-32 and R-454B, ignite only under specific conditions (e.g., ignition energy >10 , burning velocity 1-6 cm/s), with quantitative assessments indicating probabilities below 10^{-5} per year in residential HVAC due to dilution and mitigations, though empirical tests reveal sustained burns in obstructed leaks exceeding 150 g charge. Highly flammable A3 hydrocarbons like R-290 () have LFLs of 2.1% and rapid flame speeds up to 40 cm/s, heightening risks in enclosed spaces, as modeled in quantitative assessments showing indices 10-100 times higher than A1 alternatives without charge restrictions. Historical from hydrocarbon systems report few incidents (e.g., <1% of domestic fridge s attributed to refrigerant ignition from 1990-2020 in Europe), attributable to small charges (<150 g) and leak detection, but lab simulations confirm potential for overpressure s in unventilated rooms. Overall, accident statistics indicate modern synthetic refrigerants have lower empirical toxicity and flammability incident rates than early 20th-century options like sulfur dioxide, with U.S. EPA logging fewer than 50 severe HVAC-related exposures annually from 2010-2020, primarily from handling errors rather than inherent properties.
RefrigerantTypeASHRAE ClassKey Toxicity/Flammability Notes
R-134aHFCA1LC50 >500,000 ; no flame propagation; cardiac risk at >10% concentration.
HFC BlendA1Similar to R-134a; non-flammable; asphyxiation primary hazard.
R-32HFCA2LMildly flammable (LFL 14.5%); low toxicity (OEL 1,000 ).
R-290A3Highly flammable (LFL 2.1%); low toxicity but explosion risk in leaks >50 g.
R-717B2Toxic irritant (LC50 ~2,000 ); moderately flammable; multiple industrial fatalities recorded.
R-744CO2A1Non-flammable; asphyxiant (impairment at 3%); high-pressure rupture risks.
These classifications guide system design, with A1 allowing larger charges without mandatory ignition-source controls, while A2L/A3 necessitate engineering mitigations; however, real-world efficacy relies on compliance, as underreported leaks in developing markets elevate exposure risks beyond modeled probabilities.

Leak Prevention, Recovery, and Reclamation Processes

Leak prevention in refrigerant systems involves regulatory thresholds and detection methods mandated by the U.S. Environmental Protection Agency (EPA) under Section 608 of the Clean Air Act, which require owners of stationary refrigeration and air-conditioning equipment to repair leaks if the annual leak rate exceeds 20% for industrial process refrigeration, 30% for commercial refrigeration, or 10% for comfort cooling appliances containing 50 pounds or more of refrigerant. Leak rates are calculated using either an annualizing method, which prorates leaks discovered mid-year, or a 12-month rolling average to account for cumulative losses. Empirical assessments indicate that refrigerant leaks occur in approximately 19% of failed heat pump units surveyed in field studies, often due to mechanical wear at joints, valves, and coils, contributing to system inefficiencies and emissions estimated at 1-3% of total charge annually in some commercial installations. Preventive measures emphasize proactive detection and maintenance, including quarterly visual and manual inspections for commercial rack systems, as recommended by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI), alongside the use of electronic tools such as ultrasonic detectors, gas-imaging cameras, and fluorescent additives for pinpointing micro-s at rates as low as 0.5 ounces per year. Upon detection, EPA rules stipulate repairs within 30 days for most systems or up to 120 days if a test confirms the fix, with follow-up leak testing required using methods like pressurized bubble tests or electronic sniffers to ensure integrity before recharging. These protocols reduce fugitive emissions, which studies attribute to 17% of HVAC maintenance costs primarily from undercharge faults degrading by up to 20%. Refrigerant recovery entails extracting used refrigerant from systems prior to servicing, disposal, or opening for major repairs, using EPA-certified that meets AHRI 740 performance criteria for , such as achieving 90-95% removal rates depending on type and (liquid or vapor). Procedures require technicians to evacuate appliances to specified vacuum levels—4 inches of mercury for high-pressure systems like those using HFCs, or 10 inches for very high-pressure systems—while documenting the quantity and type recovered to comply with recordkeeping mandates under 40 CFR Part 82. methods include active techniques with pumps and recovery cylinders, passive methods relying on system pressure differentials, or approaches, with exemptions for systems under 15 pounds if purged with to prevent atmospheric release. Post-recovery, evacuated systems must undergo leak checks and evacuation verification before reintroduction of refrigerant, minimizing emissions during the 80-90% of service events where full is feasible. Reclamation processes reprocess recovered refrigerant to meet AHRI Standard 700 purity specifications, which demand levels equivalent to new refrigerant: moisture below 10 ppm, chloride content under 5 ppm, and non-condensables less than 1.5% by volume, achieved through , , , and oil separation to limit residual oil to 0.01% by volume. Certified reclaimers, approved by the EPA, employ multi-stage systems including passivator addition for acid neutralization, for contaminant removal, and spectroscopic analysis for , enabling reuse in the same or compatible applications without the environmental impact of virgin production. Only refrigerant meeting these standards can be resold, with EPA oversight ensuring that reclaimed material is tracked separately from recycled (on-site cleaned) stocks, reducing landfill disposal and supporting goals amid HFC phase-downs. Challenges include handling mixed refrigerants, where separation efficiency drops below 95% without advanced , underscoring the need for source segregation during .

Disposal Methods and Recycling Challenges

Disposal of refrigerants mandates to prevent atmospheric release, as required under the U.S. Agency's (EPA) 608 of the Clean Air Act, which prohibits venting during maintenance, service, repair, or disposal of air-conditioning and refrigeration equipment. Certified technicians must evacuate refrigerants using approved recovery equipment prior to scrapping appliances or systems, with small appliances like household refrigerators requiring on-site dismantling to extract intact charges. Recovered refrigerants undergo reclamation—processing to meet ARI 700 purity standards (typically 99.5% or higher) through , , and for reuse in compatible systems—or destruction via technologies achieving over 99.99% destruction and removal efficiency (DRE), such as arc or . -based methods, operating at temperatures exceeding 1300°C with steam or plasma, thermally decompose fluorocarbons into non-ozone-depleting byproducts like , which is neutralized, while avoiding incomplete risks associated with lower-temperature . Recycling challenges stem from persistently low recovery rates, with U.S. end-of-life refrigerant estimated below 20-30% in many sectors due to inadequate infrastructure, time constraints for technicians, and economic disincentives compared to venting or landfilling. In contrast, regions with deposit-refund systems or , such as parts of the , achieve 60-95% recovery, highlighting how design influences but underscoring U.S. gaps in and incentives. Contamination from mixed refrigerants or oils complicates reclamation, often necessitating costly separation techniques or favoring destruction over , as impure stocks risk system damage or reduced efficiency. Reclamation volumes have risen—HFC reclamation increased approximately 30% from 2023 to 2024 per EPA reports—yet supply remains dwarfed by virgin production demands, exacerbated by the phase-down of new hydrofluorocarbons (HFCs) under the AIM Act, which strains markets without proportional recycling scaling. Global disparities amplify challenges, as developing countries often lack certified networks, leading to higher or venting despite guidelines, while high reclamation costs (up to 50-70% of virgin refrigerant prices) deter investment absent subsidies or carbon pricing that internalizes emissions externalities. Emerging separation , such as eco-friendly chemical methods for HFC blends, show promise for improving recyclability but face hurdles in commercial adoption. Overall, while regulatory frameworks enforce , persistent barriers in , purity, and limit efficacy, often rendering destruction the more reliable disposal pathway for non-reusable stocks.

Applications and Industry Effects

Residential and Commercial HVAC Systems

In residential (HVAC) systems, such as split-system air conditioners and heat pumps, refrigerants facilitate via the vapor-compression cycle, absorbing heat indoors at the evaporator coil and releasing it outdoors at the condenser. These systems, predominant in single-family homes and small buildings, historically relied on hydrochlorofluorocarbon (HCFC) R-22 until its phaseout under the , with hydrofluorocarbon (HFC) becoming standard in units manufactured after January 1, 2010, due to its zero (ODP) and higher efficiency compared to R-22. R-410A operates at higher pressures (up to 600 ), enabling compact designs but requiring robust components. Under the U.S. Environmental Protection Agency (EPA) regulations implementing the American Innovation and Manufacturing (AIM) Act, new residential HVAC systems manufactured or imported starting January 1, 2025, must use refrigerants with (GWP) below 700, effectively prohibiting (GWP 2088) in these applications. Alternatives include mildly flammable A2L-class refrigerants like R-32 (GWP 675) and (GWP 466), which offer 10-18% higher in cooling and heating modes compared to equivalents, potentially reducing consumption by up to 10%. By mid-2025, A2L refrigerants captured 51% in U.S. unitary residential and light commercial HVAC sales, driven by preemptive manufacturer shifts. Existing systems remain serviceable with reclaimed refrigerant supplies projected to suffice through the decade, though rising costs may incentivize early replacements. Commercial HVAC systems, including rooftop packaged units, variable refrigerant flow (VRF) systems, and chillers in office buildings and retail spaces, employ similar vapor-compression principles but at larger scales, often with multiple circuits or centrifugal compressors for capacities exceeding 100 tons. dominates smaller packaged units, while R-134a (GWP 1430) is common in water-cooled chillers due to its lower operating pressures and suitability for high-capacity applications; blends like (GWP 1774) serve as retrofits for older R-22 systems in some medium-sized equipment. These systems prioritize reliability and zoning flexibility, with refrigerants selected for thermodynamic properties enabling precise amid varying loads. The AIM Act's HFC phasedown similarly restricts high-GWP options in new commercial equipment from 2025, mandating low-GWP alternatives like or R-1234ze (GWP 6) for chillers, potentially requiring design modifications such as enhanced and to mitigate mild flammability risks. Efficiency gains from these transitions mirror residential trends, with R-32-based VRF systems demonstrating up to 12% better (SEER) than counterparts in field tests. However, commercial retrofits face higher upfront costs due to larger refrigerant charges and compatibility issues, with data indicating sustained availability of legacy HFCs for maintenance until at least 2030.
RefrigerantGWPPrimary Residential/Commercial UsePhaseout Status (New Equipment, 2025+)
2088Residential splits, small commercial packagesProhibited in most new HVAC (GWP >700)
R-32675Residential heat pumps, VRF systemsApproved A2L alternative
466Residential/commercial AC unitsApproved A2L alternative
R-134a1430Commercial chillersRestricted in new chillers; service use allowed

Industrial and Automotive Uses

In industrial refrigeration, (R-717) serves as the predominant refrigerant due to its superior thermodynamic properties, high of vaporization, and cost-effectiveness in large-scale operations. It is extensively employed in plants, packing facilities, warehouses, and beverage , where systems often handle refrigeration capacities from hundreds to over 10,000 tons. Ammonia's efficiency enables lower energy consumption compared to synthetic alternatives, though its ( A3 classification) necessitates specialized handling and safety protocols in enclosed environments. Carbon dioxide (R-744) finds application in industrial cascade and transcritical systems, particularly for low-temperature processes in chemical manufacturing and certain food freezing operations, leveraging its non-toxicity and environmental neutrality despite requiring higher operating pressures up to 120 . Hydrofluorocarbons such as R-134a are used in some mid-sized industrial chillers for processes demanding non-flammable fluids, but their higher potentials have prompted shifts toward lower-GWP options like hydrocarbons (e.g., R-290) in select propane-compatible equipment for cooling. Automotive air conditioning systems historically relied on R-12 () until its phaseout in new vehicles by 1995 due to ozone-depleting effects under the . HFC-134a (tetrafluoroethane) replaced it starting with 1992 model-year vehicles in the , becoming universal by 1995 for its zero and compatibility with existing system designs, with global adoption exceeding 95% of passenger vehicles by 2000. Annual refrigerant charge per typically ranges from 0.5 to 1 kg, contributing to fleet-wide emissions when leaked during service or accidents. Regulatory pressures on HFC-134a's of 1,430 have driven transitions to HFO-1234yf () in new vehicles, mandated in from 2017 model years and increasingly adopted in models from 2013 onward, with over 100 million vehicles equipped by 2023. This mildly flammable refrigerant ( A2L) offers a GWP of less than 1, reducing lifecycle impacts by up to 90% versus R-134a, though it introduces higher system costs—estimated at $100–200 per vehicle—and requires enhanced to mitigate flammability risks in crashes. Hybrid systems exploring CO2 or hydrocarbons remain limited to niche applications as of 2025.

Transition Costs and Efficiency Trade-offs

The phaseout of high-global-warming-potential (GWP) hydrofluorocarbons (HFCs) under frameworks like the imposes substantial transition costs on industries reliant on and , including redesign of systems to accommodate mildly flammable low-GWP alternatives such as hydrofluoroolefins (HFOs) and natural refrigerants like (CO2) and hydrocarbons. These costs encompass higher upfront prices for new equipment, with HVAC systems expected to increase by 10-40% due to modified components for safety compliance and scarce low-GWP refrigerants that can cost 10-15 times more than HFCs (e.g., HFO blends at $71 per pound versus HFC-134a at $7 per pound). Overall economic burdens from HFC restrictions in the U.S. are projected to reach $428 billion in compliance expenditures from 2018 to 2050, driven by accelerated replacements and disruptions, though government analyses emphasize potential long-term savings that independent critiques argue overlook persistent price premiums passed to consumers. Efficiency trade-offs arise because many low-GWP options exhibit reduced thermodynamic performance compared to HFCs, necessitating larger compressors, enhanced exchangers, or auxiliary systems that elevate and indirect CO2 emissions over the lifecycle. For instance, CO2 systems maintain acceptable in cooler climates but suffer penalties in warmer ambient conditions, potentially increasing use by up to 20-30% relative to HFC benchmarks, while HFOs like 1234yf impose volumetric losses requiring system overdesign. Hydrocarbons and offer strong in select applications but are constrained by flammability limits, mandating charge reductions that further compromise performance and raise indirect emissions, which can offset 3-7% of direct GWP reductions in total lifecycle assessments. These dynamics highlight causal tensions: while direct refrigerant emissions decline, unaccounted energy penalties may elevate net impacts, particularly in high-demand regions, compounded by policy-driven mandates that prioritize GWP metrics over holistic evaluations including safety retrofits and operational inefficiencies. Industry analyses underscore that without technological breakthroughs, such transitions could yield minimal benefits relative to economic strains, as evidenced by contested projections of only 0.1-0.5°C warming avoidance by against billions in foregone .

Future Outlook

Emerging Refrigerant Technologies

Hydrofluoroolefins (HFOs), such as R-1234yf and R-1234ze, represent a of synthetic refrigerants developed as lower (GWP) alternatives to traditional hydrofluorocarbons (HFCs), with GWPs typically below 1 compared to over 1,000 for many HFCs. These unsaturated compounds degrade more rapidly in the atmosphere due to their double bonds, reducing long-term , though recent studies highlight potential formation of persistent byproducts like (TFA) during atmospheric oxidation, which may contribute to aquatic acidification. HFO blends, including (a mix of R-32 and R-1234yf with GWP around 466) and R-454C, are being integrated into residential and commercial HVAC systems to comply with U.S. EPA restrictions under the AIM Act, effective January 1, 2025, prohibiting high-GWP HFCs in new equipment. These mildly flammable A2L-classified refrigerants require enhanced safety features like leak sensors, yet offer comparable thermodynamic efficiency to HFC predecessors in vapor-compression cycles. Natural refrigerants, including (CO2, R-744), (R-717), and hydrocarbons like (R-290), are gaining traction through system innovations that mitigate inherent safety challenges such as and flammability. CO2 systems, operating in transcritical cycles, have seen improvements via ejector and , achieving up to 20% better seasonal performance in compared to HFC baselines, particularly in warm climates. applications are expanding beyond settings with low-charge designs reducing inventory to under 10 kg per system, enabling use in retail while maintaining zero (ODP) and GWP. refrigerants, with GWPs near zero, are advancing in domestic heat pumps and small units, supported by precise charge controls and secondary loop designs to limit flammability risks. Emerging hybrid and next-generation approaches include HFO-hydrocarbon blends and advanced cycle modifications, such as those incorporating internal heat exchangers for HFOs to boost () by 5-10%. Research into hydrochlorofluoroolefins (HCFOs) explores further pathways to minimize environmental persistence, though remains limited by costs exceeding $20/kg for some HFOs. Overall, these technologies prioritize over first-principles gains, with natural options demonstrating superior long-term climate neutrality despite higher upfront engineering demands.

Adaptation Challenges and Innovation Needs

The transition to low global warming potential (GWP) refrigerants under the American Innovation and Manufacturing (AIM) Act of 2020 and the to the presents significant adaptation challenges for the refrigeration and industry. In the United States, the Environmental Protection Agency mandates an 85% reduction in (HFC) production and consumption by 2036 relative to baseline levels established in 2011-2013, accelerating the shift away from high-GWP options like (GWP 2,088). Globally, the targets an 80-85% HFC phasedown by 2047, but uneven implementation across developing nations complicates supply chains and increases costs for imported components. These timelines necessitate rapid retrofits or replacements in existing systems, with new equipment manufactured after January 1, 2025, prohibited from using in most HVAC applications, leading to projected price increases of 10-40% for residential and commercial units due to redesigned manufacturing processes, specialized components, and technician training requirements. Safety concerns amplify these hurdles, as many low-GWP alternatives classified as A2L (mildly flammable) under Standard 34—such as R-32 (GWP 675) and (GWP 466)—require enhanced sensors, pressure relief devices, and compartmentation in systems to mitigate ignition risks, particularly in enclosed spaces like data centers or . Empirical data from field trials indicate that A2L refrigerants can propagate flames under specific conditions, necessitating costly modifications that add 5-15% to expenses and demand retraining for over 100,000 U.S. technicians by 2025. Efficiency trade-offs further complicate adoption; some (HFO)-based blends exhibit 5-10% higher energy consumption in certain cycles compared to HFCs, driven by thermodynamic properties that reduce (COP), potentially offsetting environmental gains through increased electricity demand from fossil fuel-heavy grids. Supply shortages of legacy HFCs, exacerbated by hoarding and black-market activity, have driven prices up 200-300% in 2024-2025, straining service operations for legacy equipment. Innovation is urgently required to address these gaps, prioritizing refrigerants that achieve GWPs below 150 while maintaining or exceeding HFC-level efficiency and non-flammability. into next-generation blends, such as HFO-1234yf derivatives and CO2 (R-744, GWP 1) transcritical systems, focuses on optimizing glide matching in evaporators to minimize efficiency losses, with prototypes demonstrating up to 20% improvements via variable-speed compressors tailored for low-pressure refrigerants. Advances in , including non-porous polymers for tubing to reduce leaks (which account for 10-30% of refrigerant emissions), and AI-driven algorithms, aim to enhance system longevity and reclamation rates above 90%. Safety innovations, like microchannel heat exchangers resistant to A2L flammability and integrated flame-arresting designs, are critical for broader deployment in automotive and applications. Peer-reviewed modeling underscores the need for of full lifecycle emissions, including indirect effects from higher upfront , to guide scalable solutions without unintended increases in total equivalents. Industry consortia emphasize accelerated R&D funding—projected at $5-10 billion globally by 2030—to develop drop-in compatibles and systems combining natural refrigerants with synthetic stabilizers, ensuring economic viability amid regulatory pressures.

Potential Policy Reassessments Based on New Data

Recent analyses of atmospheric data reveal that hydrofluorocarbons (HFCs) accounted for only 1.3% of total in 2023, underscoring their minor role relative to and . This empirical quantification, derived from global monitoring networks, challenges the prioritization of aggressive HFC phase-downs under the , as projected HFC emissions are expected to peak and decline naturally due to market shifts toward lower-GWP alternatives without mandatory intervention. Critics, drawing on lifecycle assessments, contend that the direct warming from HFC leaks—estimated at less than 2% of global —yields marginal climate benefits from phase-outs, often outweighed by increased and indirect CO2 emissions from less efficient substitutes. In response to data on limited alternative refrigerant availability and performance trade-offs, U.S. Environmental Protection Agency (EPA) proposals in 2025 advocate temporary relaxation of (GWP) limits for certain applications, such as raising thresholds to 1,400 for retail food refrigeration systems starting in 2026, before reverting to stricter levels by 2032. These adjustments reflect reassessments based on industry-submitted evidence of constraints and safety risks with highly flammable low-GWP options like hydrocarbons, which could elevate fire hazards in commercial settings without commensurate environmental gains. Similarly, ongoing evaluations by organizations like the Air-Conditioning, Heating, and Refrigeration Institute highlight technical challenges in scaling new refrigerants under GWP-300 limits, prompting calls for extended timelines to avoid economic disruptions estimated in billions for retrofits and efficiency losses. Further scrutiny arises from atmospheric studies documenting uneven HFC growth, particularly from non-compliant sources in developing regions, which diminish the efficacy of global caps and suggest targeted leak prevention over blanket prohibitions. Lifecycle analyses of HFC versus systems indicate that leakage rates below 10% annually—common in well-maintained equipment—result in net emissions profiles comparable to or lower than alternatives when factoring in higher operational demands of CO2-based systems. Such findings support potential recalibrations toward incentive-based programs rather than bans, prioritizing verifiable reductions in actual emissions over GWP metrics that overstate short-lived HFC impacts. This approach aligns with causal assessments emphasizing that refrigerant contributions to warming, while potent per molecule, represent a fraction amenable to technological without overhauling established .

References

  1. [1]
    [PDF] REFRIGERANTS - ASHRAE
    Refrigerants are working fluids in refrigeration, air conditioning, and heat pumping systems. They absorb heat and reject it through phase changes.
  2. [2]
    Refrigerant Safety | US EPA
    Mar 12, 2025 · "Ideal" Refrigerants​​ In addition to having the desired thermodynamic properties, an ideal refrigerant would be nontoxic, nonflammable, ...
  3. [3]
    [PDF] PROPERTIES OF REFRIGERANTS References
    Oct 13, 2021 · This table gives physical properties, safe exposure limits, GWP and ODP for compounds that have been used as working fluids in traditional.
  4. [4]
    A Complete Guide to HVAC Refrigerants - Trane®
    Aug 14, 2024 · An HVAC refrigerant, or AC refrigerant, is a liquid or gaseous cooling compound that helps your air conditioner or heat pump cool your home in ...
  5. [5]
    (R)Evolution of Refrigerants - PMC - NIH
    Refrigerants in flammability class “1” show “no flame propagation.” Class “2” refrigerants were of “lower flammability” as defined by a lower flammability ...
  6. [6]
    Scientific Assessment of Ozone Depletion 2022: Executive Summary
    The Montreal Protocol's control of ODSs stimulated the development of replacement substances, firstly HCFCs and then HFCs, in a number of industrial sectors.
  7. [7]
    [PDF] Stratospheric Ozone Depletion and the Montreal Protocol
    Apr 1, 1994 · The. 1988 Ozone Trends Panel Report, a large scale re-analysis of ozone measurements, concluded that significant ozone depletion was occurring.
  8. [8]
    Technology Transitions GWP Reference Table | US EPA
    Global Warming Potentials for HFCs, HFC Blends, and Substitutes. Substance Name. 100-Year Global Warming Potential. Reference. 2-chloropropane. 1. WMO 2022.
  9. [9]
    [PDF] IPCC Global Warming Potential Values - GHG Protocol
    Aug 7, 2024 · Unsaturated hydrofluorocarbons (HFCs) are also known as hydrofluoroolefins (HFOs), and unsaturated hydrofluorochlorocarbons (HCFCs) are also ...
  10. [10]
    Why do HFOs have lower GWPs than HFCs? - Arkema Forane
    This is precisely the difference between HFCs and HFOs when it comes to GWP. HFCs are a stable saturated molecule with longer lifetimes.
  11. [11]
    [PDF] Possibilities, Limits, and Tradeoffs for Refrigerants in the Vapor ...
    In the first approach, we evaluate the effect of a refrigerant's fundamental thermodynamic parameters on its performance in the simple vapor compression cycle ...
  12. [12]
    2.972 How A Compression Refrigeration System Works - MIT
    The refrigerant draws heat from the evaporator which causes the regrigerant to vaporize. The evaporator draws heat from the region that is to be cooled. The ...
  13. [13]
    Design of Vapor-Compression Refrigeration Cycles
    Dec 16, 1997 · We want to design a vapor-compression refrigeration cycle to absorb heat from a cool environment and reject it to a warm environment.Missing: definition | Show results with:definition
  14. [14]
    [PDF] Chapter 9 - Civil, Environmental and Architectural Engineering
    The most frequently used refrigeration cycle is the vapor- compression refrigeration cycle in which the refrigerant is vaporized and condensed alternately and ...
  15. [15]
    Refrigerants and Working Fluids | NIST
    May 3, 2011 · The thermodynamic properties (density, vapor pressure, enthalpy, heat capacity, phase behavior, etc.) determine the operating conditions ( ...Missing: definition | Show results with:definition
  16. [16]
    Thermophysical Properties of Fluid Systems - the NIST WebBook
    Accurate thermophysical properties are available for several fluids. These data include the following: Density; Cp; Enthalpy; Internal energy; Viscosity; Joule- ...
  17. [17]
  18. [18]
    Norflurane - the NIST WebBook
    Thermodynamic properties of two alternative refrigerants: 1,1-dichloro-2,2, 2-trifluoroethane (R123) and 1,1,1,2- tetrafluoroethane (R134a)Critical temperature · References
  19. [19]
    Natural and synthetic refrigerants, global warming: A review
    Jacob Perkin implemented this idea in his first refrigeration machine built in 1834. Later on, various researchers used petrol (1860s), NH3 (1873), CO2 (1886) ...
  20. [20]
    Air Conditioning and Refrigeration Timeline | ashrae.org
    1803. Thomas Moore of Maryland received US patent for refrigerator. First patent issued in US on refrigeration. ; 1805. Oliver Evans proposed a closed cycle ...
  21. [21]
    Refrigerants 1805-2030: From NH3 to Low-GWP
    Feb 15, 2022 · The first generation of refrigerant fluids (1850s) included “natural” fluids: ammonia, CO2, sulphur dioxide. These are toxic and/or flammable substances.
  22. [22]
    [PDF] 1 Refrigerators from the late 1800s until 1929 used the toxic gases ...
    Refrigerators from the late 1800s until 1929 used the toxic gases, ammonia. (NH3), methyl chloride (CH3Cl), and sulfur dioxide (SO2), as refrigerants.Missing: date | Show results with:date
  23. [23]
    The History of Refrigerants-Blogs-NEWS-Chengdu Henbin ...
    In 1874, Raoult used sulfur dioxide as a refrigerant. Sulfur dioxide and carbon dioxide have been relatively important refrigerants in history, but sulfur ...<|separator|>
  24. [24]
    (R)Evolution of Refrigerants | Journal of Chemical & Engineering Data
    Jul 2, 2020 · The original Montreal Protocol called only for a 50% reduction in the production of five of the most-common CFCs (including R-11 and R-12) as ...
  25. [25]
    Chlorofluorocarbons (CFCs) - Global Monitoring Laboratory - NOAA
    During the late 1950s and early 1960s the CFCs made possible an inexpensive solution to the desire for air conditioning in many automobiles, homes, and office ...
  26. [26]
    The Refrigerant Story: From R-22 to R-410A | Goodman Manufacturing
    In 1928, Thomas Midgley, Albert Henne and Robert McNary created chlorofluorocarbon (CFC) refrigerants. The compounds produced were “the world's first non ...<|separator|>
  27. [27]
    Stratospheric sink for chlorofluoromethanes: chlorine atom ... - Nature
    Jun 28, 1974 · Molina, M., Rowland, F. Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone. Nature 249, 810–812 (1974).Missing: discovery | Show results with:discovery
  28. [28]
    Press release: The 1995 Nobel Prize in Chemistry - NobelPrize.org
    The next leap in our knowledge of ozone chemistry was in 1974, when Mario Molina and Sherwood Rowland published their widely noted Nature article on the threat ...
  29. [29]
    R134a - National Refrigerants Ltd
    R134a (1,1,1,2-Tetrafluorethane) was introduced in 1991 under a number of different trade names such as Klea 134a, Suva 134a, Freon 134a, Forane 134a, ...Missing: date | Show results with:date
  30. [30]
    Understanding Global Warming Potentials | US EPA
    Jan 16, 2025 · The GWP is a measure of how much energy the emission of 1 ton of a gas will absorb over a given period of time, relative to the emission of 1 ton of carbon ...
  31. [31]
    Projections of hydrofluorocarbon (HFC) emissions and the resulting ...
    May 10, 2022 · Without controls, HFCs could contribute 0.28-0.44°C warming by 2100. Current policies reduce this to 0.14-0.31°C, and the Kigali Amendment ...
  32. [32]
    Hydrofluorocarbons saved the ozone layer but are warming the earth
    Dec 13, 2021 · HFCs replaced CFCs to save the ozone layer, but have a high global warming potential, hundreds to thousands of times higher than CO2.
  33. [33]
    The Social Costs of Hydrofluorocarbons and the Large Climate ...
    For example, HFC-134a, the most abundant HFC in the atmosphere, has an estimated global warming potential 1,530 times that of carbon dioxide over a 100-year ...
  34. [34]
    Background on HFCs and the AIM Act | US EPA
    The AIM Act authorizes EPA to phase down HFCs, manage them, and facilitate transition to next-gen tech. HFCs are greenhouse gases used in air conditioning and ...
  35. [35]
    Hydrofluorocarbons and the Kigali Amendment to the Montreal ...
    The 1987 Montreal Protocol, which was created to protect the diminishing ozone layer, led to a large increase in the use of HFCs.
  36. [36]
    Frequent Questions on the Phasedown of Hydrofluorocarbons - EPA
    This page features responses to common questions on the phasedown of hydrofluorocarbons (HFCs) under the American Innovation and Manufacturing (AIM) Act.
  37. [37]
    EU-Rules - Fluorinated Greenhouse Gases – Climate Action
    Phasing out hydrofluorocarbons · Expanding the quota system · 🛠️ Stricter rules to prevent emissions · Facilitating better monitoring · Capping EU production ...
  38. [38]
    F-Gas Regulation - HFC phase-down - Timeline - Danfoss
    As of 2025, also small refrigeration systems will no longer be allowed to use virgin refrigerant with a GWP >2500. This will target old systems still relying on ...
  39. [39]
    Hydrofluorocarbon phase-down in Europe
    Dec 9, 2024 · This explains why the 2025 maximum quantity for HFCs under the EU phase out is higher than 2024. Additional efforts at EU and country levels aim ...
  40. [40]
    Transitioning to Low-GWP Alternatives in Commercial Refrigeration
    Nov 18, 2024 · This fact sheet provides current information on low global warming potential (GWP) alternative refrigerants to high-GWP hydrofluorocarbons (HFCs)
  41. [41]
    [PDF] Low-GWP Alternatives in Commercial Refrigeration: Propane, CO
    In order to assist in planning and implementing ODS transitions that minimise climate impacts, the CCAC has developed this booklet of case studies on low-GWP.
  42. [42]
    Benefits and Challenges in Using Low GWP A3 Refrigerants in ...
    May 21, 2024 · This project focused on the potential climate benefits and costs of transitioning to propane refrigerant in three types of small-room air ...
  43. [43]
    Benefits and challenges in deployment of low global warming ...
    This paper focuses on the potential climate benefits and costs of transitioning to R290 refrigerant in small room air conditioning (AC) units.
  44. [44]
    A Challenging Road Ahead to Eco-Friendly Refrigerants
    May 23, 2024 · A switch to ultra-low GWP refrigerants could help slow climate change, but the current possibilities all have drawbacks, making the transition challenging.
  45. [45]
    Low GWP Refrigerants – A Guide to Sustainable Cooling - AAON
    The transition to new low GWP refrigerants imposes costs that ultimately get absorbed into the price of new HVAC equipment. These expenses are attributed to ...
  46. [46]
    Vapor Compression Cycle: A State-of-the-Art Review on ... - MDPI
    Although the VCC is considered one of the most efficient thermodynamic cycles ever made due to its high coefficient of performance (COP), it still accounts for ...
  47. [47]
    Thermodynamic performance comparison of series and parallel two ...
    The results show that compared with R134a, the proposed R600 has better performance with higher specific refrigerating capacity and coefficient of performance.
  48. [48]
    COP and volumetric capacity of selected low-GWP fluids and current...
    This figure clearly shows the COP (efficiency) versus capacity trade-off that results from an ideal analysis based only on thermodynamic properties.
  49. [49]
    [PDF] performance limits of the vapor compression cycle
    This paper explores the thermodynamic performance limits of the vapor compression cycle. We have applied evolutionary algorithms to explore the performance of ...
  50. [50]
    [PDF] High temperature heat pump using HFO and HCFO refrigerants
    Theoretical simulations of a basic heat pump cycle with various low GWP HFO and HFCO refrigerants revealed a tradeoff between performance (COP) and volumetric ...Missing: metrics | Show results with:metrics
  51. [51]
    A brief performance comparison of R1234yf and R134a in a bench ...
    Aug 9, 2025 · Test results show that the coefficient of performance and capacity of R1234yf are up to 2.7% and 4.0% lower than those of HFC134a, respectively.
  52. [52]
    (PDF) Evaluation of alternative refrigerants for R410A in ground ...
    The results showed that the R32 increases the COP value by 3.1% and reduces the mass flow rate by nearly 35%. It has been calculated that R152a provides the ...<|separator|>
  53. [53]
    comparable performance evaluation of hc and hfc refrigerants in an ...
    The evaluation showed the coefficient of performance (COP) for the studied refrigerants to be within 13 %, with R32 and R290 having the highest system COPs.Missing: metrics | Show results with:metrics
  54. [54]
    Evaluation of the carbon footprint of HFC and natural refrigerant ...
    On annual basis, the R744 unit COP is 27.5 % higher than the R134a one. However, the increased weight of the R744 unit results in significantly higher emissions ...Missing: metrics | Show results with:metrics
  55. [55]
    Experimental and Simulation Study of the Latest HFC/HFO ... - MDPI
    Mar 9, 2023 · This research paper presents the performance results of different refrigerants and blends of refrigerants that can replace the R134a1. Introduction · 2.3. Exergy Analysis · 3. Results And Discussion
  56. [56]
    Thermodynamic Performance Analysis of Hydrofluoroolefins (HFO ...
    The results also showed that the COP of the mixture decreased to 1.5% compared to R134a [40]. Different HFC and HFO refrigerants were analyzed ...
  57. [57]
    ASHRAE Refrigerant Designations
    The tables contained on this page list approved refrigerant numbers from ANSI/ASHRAE 34-2022, Designation and Safety Classification of Refrigerants, ...
  58. [58]
    Low-GWP flammable refrigerants and fire risk: The importance of ...
    May 20, 2025 · This study reviews the current research on the fire risk of flammable refrigerants and the relevant regulatory approach.
  59. [59]
    Understanding A2L Refrigerants - Fieldpiece Instruments
    Toxicity designated as A or B is defined by the occupational exposure limit (OEL). Lower toxicity refrigerants (A) have an OEL of ≥ 400 ppm while higher ...<|separator|>
  60. [60]
    [PDF] AHRI Report #08007 MATERIAL COMPATIBILITY AND ...
    This report researches material compatibility and lubricants for low GWP refrigerants, specifically the chemical and material compatibility of low GWP  ...
  61. [61]
    [PDF] Materials Compatibility of HVACR System Materials with Low GWP ...
    Jul 17, 2014 · This paper evaluates material compatibility of HFO refrigerants with elastomers, gaskets, polymers, and motor materials, including R1234yf, R ...
  62. [62]
    [PDF] MATERIALS COMPATIBILITY AND LUBRICANTS RESEARCH ON ...
    To provide compatibility information for elastomers with potential substitutes for CFC refrigerants and with suitable lubricants. s To obtain data on changes in ...
  63. [63]
    Ozone-Depleting Substances | US EPA
    Mar 25, 2025 · Learn about ozone-depleting substances, including what they are and how they contribute to ozone layer depletion and climate change.Missing: evidence | Show results with:evidence
  64. [64]
    [PDF] Part II - US EPA
    Thus, the ODP of CFC– 11 is defined to be 1.0. Other CFCs and HCFCs have ODPs ranging from 0.01 to 1.0.
  65. [65]
    [PDF] Inventory of U.S. Greenhouse Gas Emissions and Sinks: 1990-2022
    Table A-238 shows how the GWP values of. 10 the other gases relative to CO2 ... CFC-11. 4,600. CFC-12. 10,200. CFC-113. 5,820. HCFC-22. 1,760. HCFC-123. 79. HCFC ...
  66. [66]
    2.10.2 Direct Global Warming Potentials - AR4 WGI Chapter 2 - IPCC
    Table 2.14 gives GWP values for time horizons of 20, 100 and 500 years. The species in Table 2.14 are those for which either significant concentrations or ...
  67. [67]
    [PDF] UNITED NATIONS Montreal Protocol on Substances that Deplete ...
    May 20, 2022 · GWP values for CFCs and HCFCs contained in mixtures would normally be applied for the baseline years used to determine HFC baselines. Table 3.
  68. [68]
    Fluorinated Gas Emissions | US EPA
    Mar 31, 2025 · Global Warming Potential (100-year): HFCs: up to 12,400 PFCs: up to ... refrigerants with lower global warming potentials than those presently ...Missing: definition | Show results with:definition<|separator|>
  69. [69]
    [PDF] SELECTING THE RIGHT REFRIGERANT FOR COMMERCIAL ...
    The figure shows energy efficiency for varying temperatures for a baseline system architecture using the high-GWP refrigerant R-404A compared to lower-GWP ...
  70. [70]
    [PDF] Update on New Refrigerants Designations and Safety Classifications
    Nov 1, 2022 · The purpose of this fact sheet is to provide an update on ASHRAE standards for refrigerants and to introduce the new refrigerants that have been ...
  71. [71]
    Refrigerant Naming Rules, How Are Refrigerants Numbered And ...
    Sep 19, 2023 · 1. The first number is the carbon atom minus one. · 2. Add one to the number of hydrogen atoms in the second digit from the left. · 3. Chlorine is ...
  72. [72]
    [PDF] Naming and numbering HFCs, HFOs, HCFOs and HCFCs and ...
    Jun 23, 2020 · The ASHRAE 34 and ISO 817 standards numbering system for refrigerant blends is also explained here. Names - the easy part. Pre-fix.<|separator|>
  73. [73]
    ASHRAE Updates Refrigerant Designations and Safety Classifications
    May 9, 2025 · ASHRAE Standard 34 designates refrigerants with an R- followed by a number and categorizes them by toxicity and flammability. For example, "A1" ...
  74. [74]
    UNEP and ASHRAE updated list of new refrigerant designations 2025
    May 21, 2025 · ASHRAE Standard 34 “Designation and Safety Classification of Refrigerants”, is a useful tool to refer to common refrigerants using simplified ...
  75. [75]
    Refrigerants - Physical Properties - The Engineering ToolBox
    High Pressure, R12, Dichlorodifluoromethane ; High Pressure · R22, Chlorodifluoromethane ; High Pressure · R134a, Tetrafluoroethane ; High Pressure · R410A ...<|separator|>
  76. [76]
    [PDF] REFRIGERATION CLASSIFICATION, PROPERTIES, AND ...
    Jan 1, 2020 · Two HFCs that are replacing CFC-12 and HCFC-22 are HFC-134a. (Tetrafluoromethane CF3CH2F) and HFC-410A (HFC-32 & HFC-125). Hydrofluorocarbons ...<|separator|>
  77. [77]
    Possibilities, Limits, and Tradeoffs for Refrigerants in the Vapor ...
    Oct 29, 2012 · Additional chemical families, including ethers and cyclic compounds, are represented among the fluids having critical temperatures above 400 K.
  78. [78]
    Refrigerant Gases - Basic Knowledge on Gases - Technology
    They were developed mainly as refrigerant gases to be used for refrigerators and air conditioners. There are various types of fluorocarbons such as CFCs, HCFCs, ...
  79. [79]
    Categorisation of refrigerant substances and mixtures
    HFO refrigerants are also substances classified as F-gases. HFO substances differ from HFCs in molecular structure: HFO substances have a so-called double ...
  80. [80]
    [PDF] Refrigerant Table: Explanation and Glossary of Terms - HRAI
    Jul 3, 2019 · Common HCFC refrigerants are R-22, R-123, R-124, and R-142b. A blend that contains both an HCFC and HFC is considered an HCFC refrigerant. HFC ...
  81. [81]
    [PDF] the role of refrigerant mixtures
    An azeotrope is a mixture of fluids which has the same composition in the vapor phase and liquid phase, when in equilibrium. A binary azeotropic mixture is ...Missing: blends | Show results with:blends
  82. [82]
    [PDF] Designation and Safety Classification of Refrigerants - ASHRAE
    Safety classifications based on toxicity and flammability data are included along with refrig- erant concentration limits for the refrigerants. This standard.
  83. [83]
    [PDF] Specifications for Refrigerants - Fluorocarbons
    All terms in this document will follow the standard industry definitions in the ASHRAE Terminology website. (https://www.ashrae.org/resources--publications/free ...
  84. [84]
    [PDF] Designation and Safety Classification of Refrigerants - ashrae
    The dew point of a zeotropic refrig- erant blend, at constant pressure, is higher than the bubble point. Addendum z to Standard 34-2010. © ASHRAE (www.ashrae.
  85. [85]
    [PDF] A Refrigerant Producer's Experience in Manufacturing Zeotropic ...
    There have been only very limited use of zeotropic refrigerants, e.g. R-400, which is a specialty binary mixture of CFC-12 and CFC-114, until recently.
  86. [86]
    AHRI 700 (SI): Specifications for Refrigerants
    AHRI 700 establishes purity specifications and testing methods for refrigerants, including fluorocarbon, hydrocarbon, and carbon dioxide, regardless of source.
  87. [87]
    [PDF] Designation and Safety Classification of Refrigerants - ashrae
    ThisThe safety group classification in accordance with Section 6.1 is to be used in conjunction with other relevant safety standards, such as ANSI/ASHRAE Stan-.
  88. [88]
    [PDF] Refrigerant Mixtures in a Heat Pump
    This study shows that the two zeotropic refrigerant mixtures,. R32/R134a and R32/R152a, may be considered as replacements for R22 if the appropriate mixture ...
  89. [89]
    [PDF] NIST Leak/Recharge Simulation Model for Refrigerant Blends
    Generally, these blends form zeotropes, which show temperature and composition changes during evaporation, condensation, or flashing process whether it be ...
  90. [90]
    [PDF] ASHRAE Position Document on Natural Refrigerants | EPA
    The advantages of natural refrigerants have led to a significant increase in their use in recent years in applications traditionally served by fluorocarbons.
  91. [91]
    [PDF] ASHRAE Position Document on Ammonia as a Refrigerant - EPA
    Ammonia has desirable characteristics as a refrigerant, which have been well known for over a century. It is corrosive and hazardous when released in large ...
  92. [92]
  93. [93]
    A Review of Safety Issues and Risk Assessment of Industrial ...
    Aug 30, 2022 · This paper reviews the safety issues and the current practices of risk assessment with regard to the industrial ammonia used in refrigeration systems.
  94. [94]
    The Evolution of Low-Charge Ammonia Systems - Bassett Mechanical
    Feb 4, 2025 · Low-charge ammonia systems offer a significant advantage by reducing the risk of ammonia leaks while maintaining optimal refrigeration performance.<|separator|>
  95. [95]
    Transcritical CO2 Refrigeration: Basics and Benefits | The Super Blog
    Jun 23, 2020 · Learn about some basics of transcritical CO2 refrigeration and some of the benefits of using carbon dioxide as a refrigerant.
  96. [96]
    Advanced development and application of transcritical CO2 ...
    Transcritical CO 2 technology has huge advantages in terms of energy consumption, equivalent carbon content and environmental benefits.
  97. [97]
    Transcritical and Subcritical CO2 Systems Explained - SCM Frigo
    Apr 26, 2024 · Today, Transcritical CO2 cycles are used in small to large-capacity applications, with recent growth in Industrial Refrigeration. For example, ...
  98. [98]
    EPA Approves Hydrocarbon Refrigerants for Home Appliances
    Feb 2, 2012 · ... refrigerants for use in household and small commercial refrigerators and freezers: isobutane, propane, and R-441a (a proprietary, blended ...
  99. [99]
    Hydrocarbon refrigerants - Institut International du Froid (IIF)
    Jun 22, 2022 · Flammable refrigerants such as propane can be safely used in window air conditioners, due to their compact size and low refrigerant charge ...Safety standards and charge... · Hydrocarbons in domestic...<|control11|><|separator|>
  100. [100]
    Hydrocarbons | Natural refrigerants for going green - Danfoss
    The most commonly used hydrocarbons (propane and isobutane) are compatible with standard oils and materials used with HFCs. One exception is propene (propylene ...
  101. [101]
    Future Trends of Natural Refrigerants: Selection, Preparation, and ...
    Aug 8, 2024 · This review examines the relevant literature to figure out just how good ... natural refrigerants like ammonia, carbon dioxide, and hydrocarbons.
  102. [102]
    Hydrofluorocarbon refrigerants – global warming potential values ...
    Dec 13, 2024 · The lists provide:global warming potential (GWP)refrigerant ... HFO-1234ze (91.1%) HFC-227ea (8.9%), 292, A1. Non-HFC refrigerants. The ...
  103. [103]
    Acceptable Refrigerants and their Impacts | US EPA
    The restriction of HFC-134a will occur under a broader prohibition of any substances with a Global Warming Potential (GWP) higher than 150 in the MVAC sector.
  104. [104]
    Annual Greenhouse Gas Index (AGGI) - Global Monitoring Laboratory
    The annual methane increase during 2023 was 9.9 ± 0.6 ppb and during 2022 it was 13.2 ± 0.8 ppb. The atmospheric burden of nitrous oxide continues to grow over ...
  105. [105]
    HFCs contribute 1.27% to climate warming influence of greenhouse ...
    Jul 27, 2023 · The HFC impact in 2022 is now 1.27% of the total (compared to 1.19% in 2021). Direct radiative forcing from the sum of observed CFC changes ceased increasing ...
  106. [106]
    AGAGE - Advanced Global Atmospheric Gases Experiment
    Our most important finding is that HFC emissions in eastern China and Japan have sharply increased from 2016 to 2018. The contribution of East Asian HFC ...Missing: empirical | Show results with:empirical<|separator|>
  107. [107]
    Hydrofluoroolefins (HFOs): A Green Solution for HVAC Systems
    An HFO is an efficient refrigerant with very low global warming potential (GWP) and no ozone-depleting potential (ODP).
  108. [108]
    HFO refrigerants explained - Department of Energy Technology | KTH
    Oct 31, 2015 · HFOs are refrigerants composed of hydrogen, fluorine, and carbon, with at least one double bond, and are more reactive than HFCs.<|separator|>
  109. [109]
    A review of recent research on hydrofluoroolefin (HFO) and ...
    Dec 1, 2024 · This paper provides a comprehensive survey of various aspects of recent research on HFO and HCFO refrigerants, including applications in ...
  110. [110]
    Environmental impact of HFO refrigerants & alternatives for the future
    Jun 11, 2021 · HFO-1234yf causes about five times more TFA than HFC-134a (Luecken et al., 2010), i.e. HFO-1234yf transforms 100% into TFA (Behringer et al., ...
  111. [111]
    [PDF] EFCTC - REFRIGERANTS INFOGRAPHIC_FINAL - Fluorocarbons
    All of the final breakdown products of fluorocarbon refrigerants, already occur in nature in very large quantities and so HFCs & HFOs have little impact.
  112. [112]
    Phaseout of Ozone-Depleting Substances (ODS) | US EPA
    Sep 8, 2025 · New production and import of most HCFCs were phased out as of 2020. The most common HCFC in use today is HCFC-22 or R-22, a refrigerant still ...
  113. [113]
    Recent International Developments under the Montreal Protocol - EPA
    Mar 20, 2025 · On October 15, 2016, with the United States' leadership, 197 countries adopted an amendment to phase down HFCs under the Montreal Protocol in Kigali, Rwanda.
  114. [114]
    Refrigerants - CAREL
    Below is a list of the main refrigerants used in refrigeration: CFC-12 (R12): one of the most widely used last century until being banned due to its high ODP.
  115. [115]
    The Montreal Protocol banned this family of ozone-depleting ...
    Apr 3, 2023 · The Montreal Protocol banned this family of ozone-depleting chemicals. ... HFC production, which is slated for phase-down by the Kigali Amendment ...
  116. [116]
  117. [117]
    Refrigerants Part 2 - EPA Certification - SkillCat
    Sep 16, 2025 · CFCs and HCFCs are the most harmful because they contain chlorine. These refrigerants are also relatively stable, meaning they don't get ...
  118. [118]
    Montreal Protocol on Substances that Deplete the Ozone Layer
    Sep 26, 2024 · For example, Australia essentially phased out consumption of HCFC by 2016, four years ahead of the schedule required under the Montreal ...
  119. [119]
    CFCs and their substitutes in stratospheric ozone depletion.
    CFCs can destroy stratospheric ozone.​​ Whereas CFCs are safe to use in most applications and are inert in the lower atmosphere, they decompose in the upper ...
  120. [120]
    Chlorofluorocarbons and Ozone Depletion
    Apr 18, 2017 · Molina discovered that chlorofluorocarbons (CFCs) could deplete Earth's atmospheric ozone layer, which blocks the sun's damaging ultraviolet ...Widespread use of CFCs · The importance of ozone · Antarctic ozone hole
  121. [121]
    The Ozone Hole - British Antarctic Survey - Publication
    Jun 30, 2022 · In the 1970s concern about the effect of man-made chemicals, especially chlorofluorocarbons (CFCs), on the Antarctic ozone layer were raised by ...
  122. [122]
    World of Change: Antarctic Ozone Hole - NASA Earth Observatory
    In the early 1980s, scientists began to realize that CFCs were creating a thin spot—a hole—in the ozone layer over Antarctica every spring.
  123. [123]
    Decline in Antarctic Ozone Depletion and Lower Stratospheric ...
    Jan 4, 2018 · We find that there is less chlorine now than 9 years ago and that Cl y has decreased on average about 25 parts per trillion/yr (0.8%/yr).
  124. [124]
    NASA Study: First Direct Proof of Ozone Hole Recovery Due to ...
    Jan 4, 2018 · The 20 percent decrease in ozone depletion during the winter months from 2005 to 2016 as determined from MLS ozone measurements was expected.
  125. [125]
    Study: The ozone hole is healing, thanks to global reduction of CFCs
    Mar 5, 2025 · A new MIT-led study confirms that the Antarctic ozone layer is healing, as a direct result of global efforts to reduce ozone-depleting substances.
  126. [126]
    Atmospheric observation and emission estimation of HFC-125 and ...
    Nov 15, 2024 · However, HFCs are potent greenhouse gases whose global emissions were estimated as 0.88 ± 0.07 gigatonne (Gt) CO2 equivalence (CO2-eq) yr−1 in ...<|separator|>
  127. [127]
    Revealing the significant acceleration of hydrofluorocarbon (HFC ...
    Jun 26, 2024 · Our most important finding is that HFC emissions in eastern China and Japan have sharply increased from 2016 to 2018.
  128. [128]
    Emissions of HFC-23 do not reflect commitments made under ... - NIH
    Dec 21, 2024 · Here, we present updated HFC-23 emissions estimated from atmospheric observations. Globally, emissions fell to 14.0 ± 0.9 Gg yr-1 in 2023 from ...
  129. [129]
    Projections of HFC emissions and the resulting global warming
    May 11, 2022 · The results show that total CO2 equivalent global HFC emissions derived from NOAA observations continue to increase through 2019, but are about ...Missing: measured | Show results with:measured
  130. [130]
    [PDF] Lifecycle Refrigerant Management: Maximizing the Atmospheric and ...
    Recycling or reclaiming used refrigerant to decrease demand for virgin refrigerant production and create end markets for recovered gases. • Destroying recovered ...
  131. [131]
    [PDF] TEWI Analysis: Its Utility, Its Sho&mings, and Its Results - OSTI
    Estimated TEWIs for CO2 and hydrocarbon systems are lower than those for. HFC-134a systems in regions with cool climates as shown more clearly in the full ...
  132. [132]
    Assessing the environmental performance of optimized commercial ...
    Apr 30, 2024 · This study conducted a comprehensive Life Cycle Assessment (LCA) of the refrigerators, from the production to their end-of-life.
  133. [133]
    Assessment of total equivalent warming impact (TEWI) of ...
    Based on our results, HFC blend 507A refrigerants have the highest TEWI along with the maximum economic loss. Transcritical CO2 refrigeration system with ...
  134. [134]
    Comparison of the environmental impact of HFC and natural ...
    Apr 27, 2023 · In this study, a simplified life cycle comparative approach is used to evaluate and compare the carbon footprint of a traditional HFC (R134a) ...Missing: TEWI HFO
  135. [135]
    Comparative life cycle assessment of refrigeration systems for food ...
    This study presents a comparative life cycle assessment between two refrigeration systems, the first operating with a traditional fluid and the second with a ...
  136. [136]
    NIST Quest for Climate-Friendly Refrigerants Finds Complicated ...
    Feb 17, 2017 · The Environmental Protection Agency has not set specific GWP limits, but rather has conducted comparative risk analyses for each refrigerant and ...<|control11|><|separator|>
  137. [137]
    The Importance of Lifecycle Refrigerant Management in Climate and ...
    Recovered refrigerants can also be destroyed, permanently preventing their release into the atmosphere. In instances where recycling or reclamation is feasible ...1.2. Literature... · 3.1. Ozone Protection... · 3.2. Climate Change...
  138. [138]
    About Montreal Protocol - UNEP
    The Kigali Amendment will enter into force on 1 January 2019 for those countries that have ratified the amendment. The pathway to implement the HFC phase down ...
  139. [139]
    The Montreal Protocol on Substances That Deplete the Ozone Layer
    In 2016, Parties to the Montreal Protocol adopted the Kigali Amendment to phase down production and consumption of hydrofluorocarbons (HFCs) worldwide. HFCs are ...
  140. [140]
    Phaseout of Class I Ozone-Depleting Substances | US EPA
    Section 604 of the Clean Air Act establishes the phaseout targets for Class I ODS. The ban on production and import of halons took effect on January 1, 1994.Missing: adoption force
  141. [141]
    [PDF] Scientific Assessment of Ozone Depletion 2022: Executive Summary
    A clear message of the 2022 Assessment is that the Montreal Protocol continues to be effective at reducing the atmospheric abundance of ODSs. Page 12. 7.
  142. [142]
    Stratospheric ozone – depletion, recovery and new challenges - ACP
    Mar 1, 2024 · The ozone layer is recovering from the effects of halogenated source gases due to the continued success of the Montreal Protocol despite recent ...
  143. [143]
    Timeline - Ozone Secretariat
    The Kigali Amendment to the Montreal Protocol enters into force on 1 January 2019. The Amendment will reduce the projected production and consumption of ...
  144. [144]
    Potential Impact of the Kigali Amendment on California HFC Emissions
    The intent of the phase-down is to reduce emissions of potent HFC greenhouse gases with a high global warming potential (GWP) and prevent up to 0.5 degrees ...
  145. [145]
    S.2754 - 116th Congress (2019-2020): American Innovation and ...
    A bill to create jobs and drive innovation and economic growth in the United States by supporting and promoting the manufacture of next-generation technologies.
  146. [146]
    Phasedown of Hydrofluorocarbons: Notice of 2024 Allowance ...
    Oct 19, 2023 · In other words, calendar year 2024 allowances may only be expended for production and import of bulk HFCs between January 1, 2024, and December ...
  147. [147]
    Restrictions on the Use of HFCs Under the AIM Act in Variable ...
    Dec 12, 2024 · Per Congress' phasedown schedule in the AIM Act, by 2029 overall domestic production and consumption of HFCs must be reduced by 70 percent from ...
  148. [148]
    Protecting Our Climate by Reducing Use of HFCs | US EPA
    EPA issues calendar year 2026 HFC allowances and finalizes administrative consequences (10/1/2025) · Frequent Questions on the Phasedown of HFCs (updated 10/1/ ...
  149. [149]
    Phasedown of Hydrofluorocarbons: Restrictions on the Use of ...
    Oct 24, 2023 · This rulemaking restricts the use of hydrofluorocarbons in specific sectors or subsectors in which they are used; establishes a process for ...
  150. [150]
    Regulatory Actions for Technology Transitions | US EPA
    EPA may restrict HFC use by rule, with rules in Dec 2024, Dec 2023, and Oct 2023. Restrictions apply to aerosols, foams, and refrigeration, air conditioning, ...
  151. [151]
    Regulatory Actions for Managing HFC Use and Reuse | US EPA
    Oct 19, 2023 · This final rule establishes an Emissions Reduction and Reclamation Program for the management of certain HFCs and their substitutes.
  152. [152]
    EPA's HFC Emissions Reduction and Reclamation Program Finalized
    Under this new program, EPA imposed new requirements for those operating covered equipment using HFCs for repairing leaking equipment, installing automated leak ...
  153. [153]
    Proposed Rule - Federal Register
    Oct 3, 2025 · The 2023 Technology Transitions Rule established restrictions on the use of HFCs in new remote condensing unit systems and new supermarket ...<|separator|>
  154. [154]
    [PDF] Chemical, Physical, and Environmental Properties of ASHRAE 34 ...
    Thermodynamic and Transport Properties – Thermodynamic (pressure, temperature, etc.) and transport (viscosity, etc.) properties are unique to each refrigerant ...
  155. [155]
    [PDF] understanding - a2l refrigerants - Honeywell Advanced Materials
    These range from non-toxic and non-flammable. (no flame propagation) to toxic and highly flammable. Added in recent years, the A2L class allows for the use of ...
  156. [156]
    [PDF] A2l Refrigerants and ASHRAE Standard 15 - Trane
    2 This standard classifies each refrigerant into a “safety group” according to its toxicity (Class A or B) and its flammability. (Class 1, 2L, 2, or 3).
  157. [157]
    Exposure Guidance Levels for Hydrofluorocarbon-134a - NCBI
    Clinical signs of toxicity included lethargy, labored and rapid respiration, foaming at the nose, tearing, salivation, and weight loss. Rissolo and Zapp (1967) ...
  158. [158]
  159. [159]
    Appraising the flammability hazards of hydrocarbon refrigerants ...
    Aug 6, 2025 · This paper details empirical data that can be used in a quantitative risk assessment model presented in the earlier part of this study.
  160. [160]
    Comprehensive risk assessment of flammable refrigerants in HVAC ...
    Failure to promptly detect and address refrigerant leaks can lead to accidents, such as poisoning and fires. Cases of such accidents have caused panic among ...
  161. [161]
    Research on the flammability hazards of an air conditioner using ...
    Jul 2, 2025 · It is found that the possibility of refrigerant existing within the flammable range is limited only to the region very close to the indoor unit.<|control11|><|separator|>
  162. [162]
    Stationary Refrigeration Leak Repair Requirements | US EPA
    Dec 13, 2024 · Provides information on EPA's regulatory requirements for repairing refrigerant leaks.
  163. [163]
    Equipment Owners - AHRI
    According to the latest rule, there are two acceptable methods for calculating leak rate: annualizing and rolling average.
  164. [164]
    [PDF] Evaluation of Air Conditioning Performance Degradation - Publications
    Aug 17, 2018 · Similarly, Lewis (1987) surveyed 492 heat pump dealers and found that refrigerant leaks were found in 19% of failed units, while failed.<|control11|><|separator|>
  165. [165]
    [PDF] REFRIGERANT LEAKAGE ASSESSMENT - Efficiency Maine
    Mar 14, 2022 · Assuming the midpoint of 50% of charge leaked, 2% of installations leaking. 50% of their charge is a 1% leak rate (0.02 x 0.5 = 0.01). A 1% to 3 ...
  166. [166]
    [PDF] Refrigeration Systems: Leak Detection and Reduction - AHRI
    Frequent commercial rack leak checks (e.g., quarterly). Regular, manual leak prevention checks. 2. Immediate notification of refrigerant leak alarms through.
  167. [167]
    40 CFR Part 82 Subpart F -- Recycling and Emissions Reduction
    Potential methods include, but are not limited to, ultrasonic tests, gas-imaging cameras, bubble tests as appropriate, or the use of a leak detection device ...
  168. [168]
    New EPA Refrigerant Regulations Under 40 CFR Part 84 Subpart C
    Jun 2, 2025 · The facility must identify and repair the leak within 30 or 120 days of detection; · The equipment must undergo a verification test within 30 or ...
  169. [169]
    The impact of refrigerant leakage on the dynamic operating ...
    Dec 1, 2024 · According to statistics, maintenance costs due to refrigerant leakage account for 17 % of total maintenance costs [6], ranking after control, ...
  170. [170]
    Refrigerant Recovery and Recycling Equipment Certification | US EPA
    Dec 13, 2024 · Provides information on requirements for using refrigerant recovery and recycling equipment that is certified by an EPA-approved testing ...
  171. [171]
    Stationary Refrigeration Service Practice Requirements | US EPA
    Dec 13, 2024 · Describes requirements for service practices, including requirements for evacuation (and exemptions), reclamation, and changing refrigerant ...Required Level of Evacuation... · Exceptions to the Evacuation...
  172. [172]
    Refrigerant Recovery Requirements - MEP Academy
    May 31, 2023 · The amount and type of refrigerant recovered should be documented for compliance with regulations including the EPA's mandatory section 608.
  173. [173]
    Recovering, Recycling, and Reclaiming of Refrigerants | US EPA
    Sep 15, 2025 · Section 608 of the Clean Air Act include reclamation, recovery, and restrictions and requirements of refrigeration and air-conditioning equipment.
  174. [174]
    [PDF] Refrigerant Recovery and Recycling - ASE
    EPA Regulations ... Specifics include performance requirements for the recovery process, compliance with related SAE J-standards.
  175. [175]
    [PDF] Analysis of Equipment and Practices in the Reclamation Industry
    Because AHRI. Standard 700 requires that less than 0.01% oil by volume be present in reclaimed refrigerant, oil has to be removed with a dedicated separation ...
  176. [176]
    [PDF] RECLAIMED REFRIGERANT CERTIFICATION PROGRAM - AHRI
    It is mandatory for program Participants to comply with the provisions of the latest edition of AHRI Standard 700, Specifications for Refrigerants (Standard). A ...
  177. [177]
    AHRI Standard 700 The Benchmark For Reclaimed Refrigerant
    The reclamation process can include processing the used refrigerant through filters, dryers, non-condensable gases removal equipment and separation/distillation ...
  178. [178]
    Stationary Refrigeration Refrigerant Reclamation Requirements - EPA
    Mar 31, 2025 · EPA requires used refrigerant to be reclaimed by a certified reclaimer, reprocessed to a specific purity level, and returned to a consolidator ...Missing: prevention methods
  179. [179]
    Stationary Refrigeration Safe Disposal Requirements | US EPA
    Provides an overview of requirements for the safe disposal of refrigeration and air-conditioning equipment.
  180. [180]
    [PDF] Construction and Demolition: How to Properly Dispose of ... - EPA
    Safe disposal requirements for small appliances to ensure removal of refrigerants from goods that enter the waste stream with the refrigerant charge intact;.
  181. [181]
    [PDF] Responsible Appliance Disposal (RAD) Program - EPA
    Refrigerant must either be reclaimed by an EPA-certified reclaimer (see 40 CFR § 82.164) for reuse, or destroyed using approved destruction methods (see 40 CFR ...
  182. [182]
    Refrigerant Destruction (SPARC) - PyroGenesis Inc
    Operating with steam plasma as a heat source, the waste is fed continuously to the two-zone plasma reactor. With a reactor temperature of over 1300°C, the ...
  183. [183]
    Destruction and Disposal Services - A-Gas
    A-Gas offers safe destruction of refrigerants using PyroPlas technology, which has a 99.9999% destruction rate, and also handles other waste streams.
  184. [184]
    Recover, Reclaim, Reuse—the Coolest Way to Manage Refrigerants
    Jan 25, 2024 · But one of the main problems is refrigerant recovery. Most of the refrigerants are being vented instead of recovered, mainly because of a lack ...
  185. [185]
    [PDF] Staff Report - California Air Resources Board
    Oct 26, 2023 · refrigerant is recovered annually in the United States while the recovery rates are much higher in the United Kingdom (60-95 percent ...
  186. [186]
    [PDF] The 90 Billion Ton Opportunity: Lifecycle Refrigerant Management
    In regions that have instituted deposits on refrigerant or extended producer responsibility schemes, refrigerant recovery rates are higher than in other ...
  187. [187]
    Research yields eco-friendly way to separate, recycle refrigerants ...
    Feb 11, 2025 · “To increase reusability and allow for the extraction and recycling of HFC refrigerants from end-of-life units, it's essential to separate them ...
  188. [188]
    Destruction is a Better Option Than Refrigeration Recycling - Fexa
    Learn why refrigerant destruction is often more effective and environmentally friendly than the refrigeration recycling method.
  189. [189]
    Summary of Refrigerant Reclamation Trends | US EPA
    Sep 15, 2025 · In 2024, the data reported to EPA show an increase of approximately 30 percent in the total volume of HFCs reclaimed compared to 2023.
  190. [190]
    [PDF] Analysis of the U.S. Hydrofluorocarbon Reclamation Market - EPA
    information on the refrigerant reclamation market in the United States and use of HFCs in the refrigeration, air conditioning, and heat pumps (RACHP) sector.
  191. [191]
    Recover, Recycle, and Reclaim—three keys to responsible ...
    Addressing global refrigerant challenges: Recover, Recycle, and Reclaim · Ensuring leak-tight equipment · Increasing use of low- and ultra-low-GWP refrigerants ...
  192. [192]
    [PDF] ODS Destruction in the United States and Abroad - EPA
    ... destroy the refrigerant, offset credits for the destruction of the ODS ... Plasma technologies utilize plasma, which produces intense heat, to destroy ODS.
  193. [193]
    5 Reasons: Why a New R-32 HVAC System May Outshine R-410A ...
    For example, the Daikin ATMOSPHERA with R-32 has up to 12% more cooling efficiency and up to 18% more heating efficiency than comparable R-410A LV Series ...Missing: residential | Show results with:residential
  194. [194]
    R-32 Refrigerant: The New HVAC Standard vs. R-410A
    Nov 1, 2024 · Improved Efficiency: Since R-32 refrigerant more efficiently conveys heat, it may reduce electricity consumption by about 10% compared to AC ...
  195. [195]
    A2L refrigerants reach 51% share in U.S. unitary HVAC market
    Jun 16, 2025 · Central ducted HVAC systems using A2L refrigerants accounted for 51% of sales in April, with preliminary May data indicating further growth to 60%.
  196. [196]
    New Refrigerants are (Almost) Here - What You Need to Know | NAHB
    May 20, 2024 · The supply of R-410A, R-134a, and other refrigerants to meet servicing needs will remain available for the foreseeable future even as overall ...
  197. [197]
    HFC Refrigerants Used in Commercial Air Conditioning
    Apr 16, 2021 · The most popular hydrofluorocarbon (HFC) refrigerants for new commercial air conditioning systems in the US today include R-410A, R-407C, and R-134a.
  198. [198]
  199. [199]
    What to Know About the 2025 HVAC Refrigerant Change - Rheem
    In 2025, R-410A will be replaced by A2L refrigerants like R-454B and R-32 in new HVAC equipment due to EPA limits. A2L refrigerants are mildly flammable.<|separator|>
  200. [200]
    A Guide to Industrial Refrigeration | SafetyCulture
    Jun 11, 2025 · Ammonia is the most commonly used refrigerant in industrial refrigeration and was previously used in home refrigerators. It's a naturally ...
  201. [201]
    Industrial Process Refrigeration: An In-Depth Look at Each Component
    The most common refrigerants in industrial refrigeration applications is Ammonia (R717) and R-134a, which is halogen free for safety, health, and environmental ...
  202. [202]
    Which Industrial Refrigerants Are Used in Food Process ...
    Jun 22, 2022 · Non-flammable refrigerants with low toxicity are widely used currently, such as those belonging to the family of hydrofluorocarbons (HFCs).
  203. [203]
    What Is a Refrigerant? The Complete Guide For Industrial Systems
    Jul 31, 2025 · Common types of refrigerants used in industrial systems · CO₂ (Carbon Dioxide, R-744) · Ammonia (NH₃, R-717) · Hydrocarbons (e.g. Propane/R-290).
  204. [204]
    Common Refrigerant Types Used in Chillers
    Commonly available variants of refrigerant hydrocarbons are R600A (isobutene) and R290 (propane). These types of refrigerants are highly flammable, so careful ...
  205. [205]
    3 Refrigerant Types Used in Car Air Conditioners
    R12 refrigerant (freon): Until 1995, the universal refrigerant for car air conditioners was freon, the gaseous element sometimes known as R12 refrigerant.Missing: history current
  206. [206]
    Types of A/C Refrigerant Explained - Shoveltown Auto Service
    R1234yf is the most recent development in automotive refrigerants, and uses a hydrofluoric-olefin formulation rather than CFCs or HFCs. While most manufacturers ...
  207. [207]
  208. [208]
    The Shift to Eco-Friendly Refrigerants and Its Impact on Costs
    Apr 7, 2025 · New systems that use low-GWP refrigerants can cost anywhere from 10% to 40% more than traditional systems, depending on the complexity and the scale of the ...
  209. [209]
    [PDF] Trends And Developments In Low GWP Potential Refrigerants
    Sep 19, 2011 · Significant Efficiency Penalty With. Pure HFO-1234yf. Public R-32/1234yf Blend AC System Data – Trade. Off Between GWP & Efficiency. Page 22. 15.
  210. [210]
    [PDF] Next Generation Refrigerants: Standards and Climate Policy ...
    All involve significant trade-offs among GWP, energy efficiency, safety, and cost. Environmental policy must consider the indirect effects of increased CO2.
  211. [211]
    The Kigali Amendment Offers Little Benefit to the Climate, Great Cost ...
    Apr 30, 2018 · The economic impact of phasing out HFCs has yet to be comprehensively estimated. The phase-out would in all likelihood disproportionately impact ...
  212. [212]
    Atmospheric Transformation of Refrigerants: Current Research ...
    Jul 1, 2024 · Replacements for hydrofluorocarbons (HFCs) and chlorofluorocarbons (CFCs) are the hydrofluoroolefins (HFOs), which contain reactive double bonds ...
  213. [213]
    EIA warns of environmental risks from HFO refrigerants in new report
    Jul 29, 2025 · According to the report, HFOs are often marketed as sustainable alternatives to hydrofluorocarbons (HFCs), yet their production and atmospheric ...
  214. [214]
    Technology Transitions HFC Restrictions by Sector | US EPA
    Beginning January 1, 2025, certain technologies may no longer use high global warming potential (GWP) hydrofluorocarbons (HFCs) or HFC blends.Missing: emerging | Show results with:emerging
  215. [215]
    [PDF] NATURAL REFRIGERANTS SUSTAINABLE FUTURE - IIAR
    Natural refrigerants were the first refrigerants to be utilized for food and beverage production and storage in the 19th century due to their availability ...
  216. [216]
    Natural Refrigerants Cooling & Heating News / Marketplace
    World's No1 source of news & insights about natural refrigerant based cooling and heating technologies since 2006.
  217. [217]
    Future proof heating and cooling with natural refrigerants - GEA
    May 23, 2023 · Ammonia, hydrocarbon and carbon dioxide refrigerants offer the most energy efficient and cost-saving alternatives to their synthetic counterparts.
  218. [218]
    EPA Issues Final HFC Rule: What HVAC Companies Should Know
    Oct 3, 2024 · The HFC rule mandates a phased reduction in the production and use of these harmful greenhouse gasses. For HVAC companies, this regulation represents both a ...Missing: consumer | Show results with:consumer
  219. [219]
    Rethinking time-lagged emissions and abatement potential of ...
    Aug 6, 2024 · The Kigali Amendment outlines a target reduction of 80%–85% in global HFC production and consumption by 2047, with respect to baseline levels, ...
  220. [220]
    [PDF] Benefits and Challenges in Using Low GWP A3 Refrigerants in ...
    For example, many lower-GWP refrigerant alternatives for air conditioning systems are mildly flammable (or Class A2L) refrigerants that require specific safety ...
  221. [221]
    Embracing Sustainable Cooling: Preparing for the 2025 GWP ...
    Adopting low-GWP refrigerants comes with challenges, including ensuring they meet safety and performance standards. Some alternatives can be mildly flammable, ...<|separator|>
  222. [222]
    Low-GWP Refrigerants for Refrigeration Systems
    Current low-GWP alternatives may increase energy consumption, introduce safety risks, and require significant equipment modifications.Missing: innovation needs efficiency
  223. [223]
    Hunting sustainable refrigerants fulfilling technical, environmental ...
    This work presents an integrated approach for the rational design of low-GWP refrigerant blends, focused on replacing R134a (GWP 1430), and R410A (GWP 2088).
  224. [224]
    Garrett's Centrifugal Compressor for Low-GWP Refrigerants
    Sep 26, 2025 · But succeeding requires cooling technologies engineered for reliability, safety, and efficiency from the start.
  225. [225]
    Innovative Technologies In Low-GWP Refrigeration Systems
    Nov 22, 2023 · As mandated by the AIM Act, the commercial refrigeration industry is transitioning away from high-GWP refrigerants, such as R-404A and ...<|separator|>
  226. [226]
    Study on the impacts of refrigerant leakage on the performance and ...
    A 20 % leakage could increase indirect carbon emissions by 6.3 %. Abstract. The escalating threat of global warming has highlighted the imperative to address ...
  227. [227]
    EPA Proposes New Refrigerant Rule | ACHR News
    Oct 2, 2025 · For retail food refrigeration, EPA is proposing to raise the GWP threshold to 1,400 (from 150 or 300), starting in 2026 for remote condensing ...
  228. [228]
    [PDF] The EPA Administrator, Lee Zeldin, signed the following proposed
    Sep 30, 2025 · Data regarding which refrigerants are being considered or adopted in new refrigeration equipment for remote condensing units, supermarket ...
  229. [229]
    AHRI to Launch Industry-Wide Initiative to Evaluate New Low-GWP ...
    Jul 29, 2025 · AHRI's initiative aims to evaluate new low-GWP refrigerants (under 300) for HVACR, identify replacements, and understand technical challenges, ...Missing: reassessment | Show results with:reassessment
  230. [230]
    Sustained Increases in Hydrofluorocarbon Emissions from China ...
    Feb 10, 2025 · The HFC-125 emissions for China have increased from almost zero in 2005 to 28.7 ± 3.4 Gg yr–1 in 2022 (Figure 4a), which is consistent with that ...
  231. [231]
    A Restricted Climate Super Pollutant Is Pumped Out at Far Higher ...
    May 21, 2025 · HFC-23 emissions from chemical plants in eastern China and elsewhere likely violate an international climate agreement despite readily available pollution ...
  232. [232]
    Control of HFC-23 Emissions | US EPA
    Hydrofluorocarbon (HFC)-23 is a potent greenhouse gas with a 100-year global warming potential (GWP) of 14,800. While there are limited instances where ...Missing: 2023-2025 | Show results with:2023-2025