Fact-checked by Grok 2 weeks ago

Resettable fuse

A resettable fuse, also known as a polymeric positive (PPTC) device, is a passive designed to protect electrical circuits from faults by automatically increasing its resistance in response to excessive or , thereby limiting damage without requiring manual replacement. Constructed from a non-conductive crystalline polymer matrix infused with conductive particles, the device maintains low resistance under normal operating conditions, allowing to flow freely through interconnected particle chains. When an or overtemperature event occurs, causes the polymer to expand into an amorphous state, separating the particles and exponentially raising resistance—often by several orders of magnitude—to a "tripped" condition that restricts flow and dissipates . Once the fault is cleared and the device cools, it self-resets to its original low-resistance state, restoring circuit functionality. Key characteristics of resettable fuses include a hold current (the maximum steady-state without tripping, typically up to 15 A) and a trip current (the minimum current that initiates the high-resistance state, often around twice the hold current), with operating voltages ranging from low DC levels up to 60 V or more in specialized models. Unlike traditional fuses, which must be physically replaced after blowing, PPTC devices offer advantages such as reduced maintenance, enhanced reliability in hard-to-access locations, and suitability for high-volume automated assembly due to their compact, solid-state design. They are widely applied in consumer electronics like battery-powered devices (e.g., laptops and smartphones), automotive systems (e.g., and power distribution), telecommunications, and USB/data line protection, where frequent fault recovery is beneficial. Standards compliance, such as AEC-Q200 for automotive use and for environmental safety, ensures their integration into modern, regulated applications.

Introduction

Definition and Principle

A resettable fuse, also known as a polymeric positive (PPTC) device, is a passive designed for protection in circuits by automatically limiting excessive . The fundamental principle of operation relies on the device's temperature-dependent characteristics. At normal operating temperatures, the PPTC maintains a low , permitting unimpeded through the circuit. Under conditions, the resulting heat generation causes the internal structure to expand, which separates conductive pathways and triggers a sharp increase in —often by several orders of magnitude—effectively restricting to a minimal, level without fully interrupting the circuit. In contrast to traditional one-time fuses, which permanently melt and sever the circuit upon activation, requiring manual replacement, PPTC resettable fuses automatically revert to their low-resistance state after the fault is cleared and the device cools sufficiently. This self-resetting capability enhances reliability and reduces maintenance needs in protected systems.

History

The positive temperature coefficient (PTC) behavior in composites, which forms the basis of resettable fuses, was first discovered by Gerald L. Pearson at Bell Laboratories in 1939. Pearson's work involved embedding conductive particles in an insulating matrix to create a device with a sharp increase in resistance at elevated temperatures, as detailed in US patent 2,258,958. Although Pearson envisioned potential uses for circuit protection, the discovery did not lead to immediate commercial products. Subsequent research in the and built on this foundation through studies of conductive , including carbon-black-filled composites that exhibited PTC effects. These efforts, often involving experimental exploration of electrical in matrices, resulted in multiple rediscoveries of the and provided key insights into the mechanisms driving resistance changes. However, challenges in material stability and manufacturing limited practical implementation during this era. Commercialization accelerated in the 1970s with Corporation's development of PTC materials into viable protection devices. filed the initial s for using PTC polymers as resettable circuit protectors and launched the PolySwitch product line, marking the first widespread adoption of these devices in electrical systems. In the and , evolution focused on refining polymer compositions for enhanced performance in . Advances in crosslinking techniques and conductive filler optimization, as exemplified in 's PTC formulations, improved device reliability, trip speed, and compatibility with integrated circuits. Since 2000, modern advancements have emphasized through surface-mount designs and expanded voltage capabilities to support compact, high-power applications. For instance, the introduction of low-profile SMD formats enabled into portable , while recent innovations like 60 V-rated devices address overvoltage needs in advanced systems.

Construction and Materials

Materials Used

Resettable fuses, particularly polymeric positive (PPTC) devices, rely on a core material composed of a semi-crystalline matrix doped with conductive fillers to achieve their protection function. The matrix is typically (HDPE) or similar semi-crystalline thermoplastics, which provide the necessary thermal sensitivity for the PTC effect. These polymers are blended with conductive particles, most commonly , at concentrations ranging from 10% to 40% by to form a low-resistance conductive under normal operating conditions. While is the most common, other conductive fillers such as may also be used. The crystallinity of the enables significant when heated, separating the conductive fillers and dramatically increasing . Electrodes in PPTC resettable fuses are constructed from metal leads or terminations to facilitate electrical and ensure uniform through the polymer matrix. Common materials include tin-plated or tin-plated wires, often in gauges such as 20 to 24 AWG, which offer good and . These electrodes are bonded directly to the composite, forming a robust interface that maintains performance during thermal cycling. Encapsulation plays a critical role in protecting the internal components from environmental factors like moisture, chemicals, and mechanical stress. Insulating coatings, such as epoxy resin or , are applied over the polymer core and electrodes to provide dielectric isolation and enhance durability. Material variations are employed to meet specific application requirements, such as high-temperature tolerance or low-profile configurations. For high-temperature designs, modified semi-crystalline with elevated melting points replace standard to support operating temperatures up to 125°C or higher. Low-profile surface-mount devices often utilize thinner layers of the same polymer-carbon black composite, combined with flexible electrode foils, to achieve compact form factors suitable for space-constrained .

Manufacturing Process

The manufacturing process of resettable fuses, commonly referred to as polymeric positive temperature coefficient (PPTC) devices, commences with . This involves intimately mixing a non-conductive semi-crystalline , such as , with finely divided conductive particles, typically , in precise proportions under controlled temperature and shear conditions to form a homogeneous composite. The mixture achieves a low initial resistance through interconnected conductive pathways while enabling the PTC effect upon heating. Following , the material undergoes to shape it into intermediate forms like thin sheets, rods, or pellets, often using melt-processing techniques to maintain uniformity and avoid degrading the matrix. These extrudates are then precisely sliced or molded into device-specific geometries, such as radial discs, surface-mount straps, or axial components, ensuring consistent thickness for reliable thermal response. Electrodes, usually consisting of tinned or nickel-plated foils, are subsequently attached to opposing sides of the polymer element via under heat and pressure or conductive , providing robust electrical terminals and uniform current distribution. The assembled elements are then encapsulated in protective coatings, such as flame-retardant resins compliant with V-0 standards, followed by curing through controlled heating and compression to bond layers, eliminate voids, and enhance mechanical and thermal stability. This step also incorporates optional insulating wraps or housings for specific form factors. concludes the process, encompassing electrical testing for initial room-temperature resistance (using four-wire methods), hold and trip currents, PTC transition temperature (typically around 110–130°C), and endurance cycling to confirm compliance with industry standards like UL 1434. Devices failing these metrics are rejected to ensure batch reliability.

Operation

Normal State

In the normal state, a resettable fuse, typically a polymeric positive temperature coefficient (PPTC) device, operates in a low-resistance mode that functions essentially as a near-short in the path. This low resistance, often less than 1 and ranging from a few milliohms to a few ohms depending on the device, allows the rated hold current (I_h) to flow through without causing a significant or impacting performance. Under standard operating conditions, the device maintains , where the heat generated by the passing current is effectively dissipated into the surrounding environment, keeping the internal matrix below its transition temperature of typically 80–130 °C. The resettable fuse is designed to function within specified voltage and limits during this normal state, with a maximum continuous voltage (V_{max}) typically ranging from 6 V to 600 V and the hold (I_h) representing the maximum steady-state that can pass without tripping, often up to 15 A at 23°C ambient . These ensure reliable without nuisance interruptions in normal use. Power dissipation in the normal state follows the P = I^2 R, where P is the , I is the , and R is the device's low ; the minimal R value results in low P, which is readily dissipated to prevent any rise toward the transition temperature and thus maintains thermal stability.

Tripped State

When the current through a resettable fuse exceeds its trip current (I_T), which is typically 2 to 3 times the hold current (I_H), the device generates excess due to I²R losses in the matrix. This heat causes the polymer to expand, disrupting the conductive paths formed by embedded carbon particles and transitioning the material from a low-resistance crystalline to a high-resistance amorphous . In the tripped state, the resistance increases dramatically—often by three to four orders of magnitude—to values exceeding 10 kΩ, effectively limiting the fault current to a low leakage level while the voltage drop across the device approaches its maximum rated voltage (V_max). This high-resistance condition persists as long as the overcurrent fault remains, providing ongoing protection without permanent interruption of the circuit. Upon removal of the fault condition, the device self-resets automatically as the cools and contracts, restoring its original low-resistance state and allowing normal current flow to resume. The time to reset typically ranges from several seconds to a few minutes, depending on ambient conditions, device size, and the extent of heating during the trip event. The tripped mechanism prevents by rapidly increasing to isolate conductive hotspots within the , thereby dissipating heat safely and avoiding irreversible damage to the device or protected circuitry.

Electrical Characteristics

Key Parameters

Resettable fuses, also known as polymeric positive (PPTC) devices, are characterized by several key electrical and thermal parameters that determine their suitability for overcurrent protection in various circuits. These parameters guide selection based on the application's operating conditions, ensuring the device maintains low under normal loads while transitioning to high during faults. Typical values vary by manufacturer and series, but they generally fall within established ranges for common devices. The hold current (Ih) represents the maximum continuous current the device can carry without tripping, measured in still air at 20–23°C. This parameter is critical for matching the fuse to the circuit's normal operating current, with a recommended margin of at least 20% below the expected load to account for tolerances and derating. For example, hold currents typically range from 0.05 A to 14 A across surface-mount and radial-leaded series. The trip current (It) is the minimum current level at which the device is guaranteed to switch to its high-resistance state, also specified at 20–23°C in still air. It is often approximately twice the hold current, providing a defined for fault detection. Typical trip currents range from 0.15 A to 18.7 A, depending on the device size and formulation. Trip time (td), or time to trip, denotes the maximum duration from the application of the trip until the device reaches a high-resistance state, typically measured at 20–23°C. This parameter influences response speed during events, with faster times desirable for sensitive applications; values commonly span milliseconds to several seconds, such as 0.10 s to 7.0 s at currents 4–8 times the hold current. The maximum voltage (Vmax) specifies the highest continuous voltage the device can withstand in the tripped state without damage or . It ensures safe operation across the power supply rating, with typical values from 6 Vdc to 600 Vdc for low- to line-voltage applications. For instance, many surface-mount devices are rated at 6–60 Vdc. Resistance values are defined by the initial resistance (R_min), the low-resistance state before tripping at 20–23°C, and the tripped resistance (R_max), the elevated resistance after (often measured one hour post-trip at the same ). R_min ensures minimal under normal operation, typically 0.018 Ω to 3.60 Ω, while R_max limits fault , ranging from 0.080 Ω to 20.00 Ω or higher during the hot tripped state. The ratio of R_max to R_min often exceeds 10:1, providing effective . Temperature dependence is governed by the switching temperature (Tmelt), the point at which the polymeric matrix undergoes a phase change, activating the PTC effect and causing rapid resistance increase. This parameter, also known as the or activation temperature, typically falls between 100°C and 125°C for commercial devices, influencing both current-induced and ambient-heat tripping. Performance derates with ambient , requiring adjustments for operating environments outside 20–23°C.

Performance Curves

Performance curves for resettable fuses, also known as polymeric positive coefficient (PPTC) devices, graphically illustrate their behavioral response to varying electrical and thermal conditions, aiding engineers in selecting appropriate components for protection. These curves typically include versus , time-to-trip versus , and voltage-current (V-I) characteristics, each revealing the device's transition from a low- conducting state to a high- limiting state. Interpretation of these curves requires consideration of standard test conditions, such as 23°C ambient , unless otherwise specified, as varies with environmental factors. The resistance versus temperature curve demonstrates the core PTC effect, where resistance remains relatively stable and low below the device's trip (typically around 125°C, denoted as Tmelt), then exhibits a sharp increase—often by orders of magnitude—as the polymer matrix expands and disrupts conductive pathways. This transition highlights the device's self-regulating nature, with the steep rise indicating the onset of the high-resistance state that limits current flow without permanent damage. For instance, in standard PPTC materials, resistance can jump from milliohms to tens or hundreds of ohms within a narrow temperature band near Tmelt, enabling rapid fault response while allowing automatic reset upon cooling. Time-to-trip versus current curves plot the duration required for the device to reach its high-resistance state against applied fault , often using a for currents to capture the inverse relationship: higher fault currents result in faster tripping due to accelerated self-heating from I²R losses. These curves, derived from average performance under controlled conditions, show that trip times decrease nonlinearly with increasing current multiples above the hold (Ih), typically ranging from seconds at 2× Ih to milliseconds at 10× Ih or more. For example, in a device with Ih = 0.5 A, such as the 1206L050, the maximum time to trip at 8 A is 0.1 seconds, though typical values may be shorter depending on the exact fault profile. Voltage-current (V-I) characteristics, often plotted as across the device versus , reveal a low in the normal operating state due to the minimal (e.g., a few ohms), resulting in small at rated below Ih. In the tripped state, the curve becomes nearly vertical, reflecting the high (tens to thousands of ohms) that maintains low leakage even as applied voltage increases up to the maximum (Vmax), effectively clamping fault to a safe level. This behavior underscores the device's role as a rather than an open-circuit interrupter, with the steep tripped-state indicating robust isolation. Several factors influence these curves, necessitating for real-world applications. Ambient reduces the effective hold and currents, as shown in temperature rerating curves; for instance, many devices operate at 50% of their 20°C-rated current at 85°C due to reduced thermal headroom for self-heating. Voltage derating is also critical, with performance degrading above 60-80% of Vmax to avoid arcing or incomplete tripping, particularly in high-voltage designs. These adjustments ensure reliable operation across varying conditions, but users must validate curves in specific circuits as actual performance can deviate due to mounting, airflow, and dynamics.

Types and Variants

By Form Factor

Resettable fuses, also known as polymeric positive temperature coefficient (PPTC) devices, are categorized by form factor to suit various mounting and assembly requirements in electronic circuits. These physical packaging styles influence compatibility with printed circuit boards (PCBs), ease of installation, and thermal management, with smaller designs generally prioritizing space efficiency over higher current handling. Surface-mount devices (SMD) represent a compact designed for automated assembly, typically appearing as small chips without leads. Common sizes include 1206 (3.2 mm × 1.6 mm) and 1210 (3.2 mm × 2.5 mm) packages, supporting hold currents from 0.05 A to 2 A, with maximum voltages up to 60 V. These are ideal for high-density where enables precise placement, though their limited surface area restricts heat dissipation, capping ratings at lower currents compared to larger formats. Radial leaded resettable fuses feature through-hole components with wire leads extending radially from a disc-shaped body, facilitating manual or and easy replacement in prototypes or repairs. Available in diameters from 5 mm to 20 mm with lead spacings of 5.1 mm or 10.2 mm, they handle hold currents ranging from 0.1 A to 20 A and voltages up to 600 V. This design allows better airflow around the body for cooling, enabling higher current ratings than SMD variants, but requires more board space. Axial leaded or strap configurations cater to high-current needs, often resembling cylindrical or flat straps with leads on opposite ends for into power circuits. These support hold currents up to 13 A or more, such as 1.1 A to 13 A in strap series, with voltages typically 12 V to 30 V. The elongated shape enhances in power supplies, but the demands careful layout to avoid mechanical stress on joints. Strap or blade types provide custom, robust packaging for modular applications like battery packs and automotive systems, often with flat straps or blade terminals for direct or clipping. Blade variants mimic standard shapes (e.g., 2.8 mm or 5.4 mm wide) and offer hold currents up to 10 A at 32 V, while strap series range from 1.1 A to 7.3 A. These prioritize and quick integration but are constrained by size to moderate currents due to thermal buildup in enclosed modules. Overall, selection directly affects performance limits, as smaller packages like SMD exhibit reduced current ratings owing to inferior thermal dissipation, necessitating in ambient temperatures above 85°C across all types.

By Specifications

Resettable fuses, also known as polymeric positive temperature coefficient (PPTC) devices, are classified by their electrical ratings and environmental tolerances to suit diverse circuit needs. Low-voltage series are typically rated for maximum voltages below 60 VDC, making them suitable for such as USB ports and battery-powered gadgets where operating voltages range from 6 V to 60 V. These series, like the 0805L and 2920L from , provide reliable in low-power environments without exceeding safe voltage limits. In contrast, high-voltage series extend up to 600 V, targeting and industrial applications, including 72 V systems. For instance, Littelfuse's 600R radial series and telecom line-rated devices handle voltages from 60 VDC to 250 VDC with interrupting ratings up to 600 VDC, ensuring robust protection in higher-power setups. Bourns Multifuse products also offer variants up to 72 V in their MF-RX/72 series for similar demanding environments. Temperature-rated variants distinguish between automotive-grade and standard types based on operating ranges and certifications. Automotive-grade PPTC fuses, compliant with AEC-Q200 standards, operate from -40°C to 85°C, withstanding vibration and thermal cycling in vehicle applications like motor protection. Standard variants similarly cover -40°C to 85°C but lack automotive-specific qualifications, suiting general electronics with less extreme conditions. High-temperature variants, such as Bourns' MF-USHT series introduced in 2025, extend operation up to 125°C for more demanding environments. High-hold current types exceed 5 A, designed for power-intensive applications requiring sustained current handling before tripping. Examples include Littelfuse's 16R radial series with hold currents up to 14 A at 16 V and the RUEF500 from at 5 A hold with 30 V rating, providing low-resistance protection in high-load circuits. Specialized variants incorporate features like flame-retardant materials meeting V-0 standards or low-profile designs for space-constrained assemblies. Bourns Multifuse and PolySwitch devices use cured, flame-retardant epoxy coatings to enhance in enclosed systems. Low-profile options, often in surface-mount device (SMD) form factors detailed elsewhere, minimize height in compact boards, such as battery strap series with narrow profiles.

Applications

Consumer Electronics

In consumer electronics, resettable fuses, particularly polymeric positive temperature coefficient (PPTC) devices, provide essential protection in low-power portable and home devices, ensuring safety without requiring manual replacement. Their adoption has grown significantly since the , driven by the proliferation of compact, battery-powered gadgets such as smartphones and laptops, which demand reliable, space-efficient safeguards against faults like short circuits and overloads. A key application is in USB ports and chargers, where resettable fuses protect data lines and power delivery from short circuits, typically supporting hold currents around 500 mA to match USB standards. For instance, Bourns' Multifuse PPTC devices are designed for USB 2.0 and 3.0 interfaces, increasing resistance exponentially under fault conditions to limit current flow while allowing automatic reset after the issue is resolved and power is cycled. This self-resetting feature minimizes downtime in everyday charging scenarios. In packs for and smartphones, resettable fuses prevent damage from overcharge, over-discharge, or internal short circuits by interrupting current during faults and restoring normal operation once conditions normalize. Eaton's PTC fuses are commonly integrated into lithium-ion packs for mobile phones, tablets, and , offering hold currents up to 15 A and voltage ratings to 60 V DC, which suits the sealed nature of these devices where replacement is impractical. Similarly, devices like Raychem's PolySwitch straps have been used since the early in cell phone and packs to handle hold currents of 1.7–2.3 A, reducing from repeated fault . Power adapters benefit from resettable fuses that safeguard internal components, such as transformers, against overloads in linear supplies. PolySwitch PPTC devices, available in surface-mount and radial-leaded forms, provide this protection with hold currents ranging from 0.05 A to 14 A and voltage ratings up to 600 V, automatically resetting to maintain continuous operation without interrupting user access to the device. In , resettable fuses protect speakers from amplifier faults like DC offset or surges, limiting power to prevent damage. Bourns Multifuse PTC fuses are specified for this use, either shunting excess or increasing to cap flow during excursions, ensuring the system recovers without component swaps.

Automotive and Industrial

In automotive applications, resettable fuses provide essential protection for electronic control units (ECUs), where they safeguard sensitive circuitry against faults in harsh vehicle environments. These devices, qualified under the AEC-Q200 standard, ensure reliability in high-vibration and extreme temperature conditions typical of automotive systems. For motor controls, particularly in electric vehicles, resettable fuses protect drive circuits and batteries from overloads, allowing automatic reset after fault clearance to minimize downtime. They are also deployed in circuits to handle currents, with voltage ratings up to 32 V supporting compact, surface-mount designs. In industrial settings, resettable fuses are integrated into programmable logic controllers (PLCs) to protect against transient overcurrents from or switching events. For relays, they offer resettable safeguarding in control panels, preventing damage from inrush currents while enabling quick recovery without replacement. In welding equipment, these fuses manage high transient overcurrents in power supplies, ensuring operational continuity in demanding manufacturing processes. Telecommunications infrastructure relies on resettable fuses in base stations and routers to mitigate power line faults, such as those caused by or inductive surges. These devices protect multiple supply lines, including connections, by tripping during high-voltage events and resetting once conditions normalize, thus avoiding service interruptions in networking equipment. In , resettable fuses are used in inverters to provide overload protection, tripping during short circuits or excessive loads and automatically restoring function to support continuous power conversion. For solar charge controllers, they guard against from panel mismatches or environmental surges, enhancing system reliability in off-grid setups. Resettable fuses for automotive and industrial use are engineered for harsh environments, featuring vibration resistance certified under AEC-Q200 to withstand stresses in and machinery. They operate across wide ranges, typically from -40°C to 125°C, ensuring performance in extreme thermal conditions without degradation.

Advantages and Disadvantages

Benefits

Resettable fuses, also known as polymeric positive temperature coefficient (PPTC) devices, provide significant advantages over traditional one-time fuses and breakers through their inherent reusability. Unlike traditional fuses that permanently melt and require physical replacement after tripping, resettable fuses automatically return to their low-resistance state once the fault is cleared and the device cools, eliminating replacement costs and associated downtime. This reusability is particularly beneficial in applications where frequent faults occur, as it allows the device to protect the multiple times without intervention. The automatic reset feature further enhances system reliability by requiring no manual intervention, which improves overall uptime in scenarios such as remote where access for servicing is limited. In these environments, the self-resetting action ensures continuous operation post-fault without the need for on-site technicians, thereby minimizing disruptions. Additionally, this behavior limits current to a low-leakage level during a fault without fully opening the , enabling ongoing diagnostics and monitoring of the system without complete power interruption. Resettable fuses also offer a compact , often available in surface-mount packages as small as 0603 size, making them ideal for space-constrained designs where larger circuit breakers or even traditional fuses would be impractical. This smaller footprint facilitates integration into high-density printed circuit boards in and portable devices. Over the long term, despite a potentially higher initial cost compared to traditional fuses, resettable fuses yield significant savings by reducing maintenance, service calls, and warranty expenses in high-cycle applications, as the elimination of repeated replacements offsets upfront investments.

Limitations

Resettable fuses, particularly polymeric positive temperature coefficient (PPTC) devices, exhibit slower response times compared to traditional fast-blow fuses, with typical trip durations exceeding 1 ms and often reaching several seconds under fault conditions, such as 1 second at elevated currents like 5 A. This delay arises from their reliance on to increase resistance, making them unsuitable for applications requiring extremely fast interruption, such as under 1 ms for certain sensitive semiconductors to prevent damage. In contrast, fast-blow fuses achieve near-instantaneous opening in milliseconds or less at multiples of their rated current. Initial costs for PPTC resettable fuses are typically 2-5 times higher than those of equivalent wire or traditional fuses due to their specialized construction and manufacturing complexity. This premium reflects their resettable functionality but can be a barrier in cost-sensitive, high-volume applications where one-time fuses suffice. The larger of PPTC devices compared to minimalist wire fuses limits their use in ultra-high-density boards, as they require additional spacing to manage buildup and prevent unintended neighboring component interference. In the tripped state, these fuses generate significant from residual leakage flowing through their elevated (often 10-100 times the initial value), potentially reaching surface temperatures up to 125°C and necessitating or enhanced cooling in confined designs. Voltage limitations further restrict PPTC applicability; general-purpose models are not rated above 60 V, and while specialized variants reach 600 V, they require for AC circuits due to arcing risks during zero-crossing and inductive loads, rendering them less ideal for mains or high-DC systems exceeding 600 V without supplemental protection. Exceeding these ratings can cause permanent damage or failure to trip effectively. Repeated tripping leads to cycling fatigue in PPTC fuses, where resistance can increase progressively—potentially doubling after 200 cycles and further rising beyond 300—due to , limiting reliable operation to around 1000 cycles maximum before performance degrades. This accumulation reduces hold current tolerance and increases power dissipation over time, making them unsuitable for frequent fault environments without monitoring.

Standards and Specifications

Certifications

Resettable fuses, particularly polymeric positive temperature coefficient (PPTC) devices, undergo rigorous certification to ensure safety and reliability in overcurrent protection applications. The UL 1434 standard, established by Underwriters Laboratories, specifically governs thermistor-type devices including PPTC resettable fuses, focusing on construction, performance, and testing for overcurrent protection to prevent hazards like overheating or fire. In North American markets, approvals under the Component Acceptance Program certify PPTC devices for compliance with Canadian , often aligned with UL 1434 through the cUL , ensuring equivalent protection against faults in end-use equipment. For European markets, VDE approvals, issued by the VDE , verify adherence to safety norms such as EN 60730-1, confirming that resettable fuses meet requirements for insulation, thermal stability, and in consumer and industrial products. Automotive-grade resettable fuses must satisfy AEC-Q200 qualification from the Automotive Electronics Council, which includes stress tests for thermal cycling, mechanical vibration, and high-temperature storage to guarantee durability in harsh environments, with specific provisions in AEC-Q200-004 for polymeric PTC materials. RoHS compliance, mandated by the European Union's (2011/65/EU), requires resettable fuses to be free of lead, mercury, , and other restricted materials, promoting environmental safety while maintaining performance; manufacturers like and Bourns confirm this for their PPTC lines through material declarations and testing. Internationally, the IEC 60730-1 standard from the applies to automatic electrical controls in household appliances, certifying PPTC resettable fuses for operational reliability, endurance cycling, and fault protection under clauses addressing scenarios, as verified by approvals for devices used in appliances like washing machines and refrigerators.

Testing Methods

Testing methods for resettable fuses, or polymeric positive temperature coefficient (PPTC) devices, encompass standardized procedures to evaluate their operational reliability, resistance stability, and endurance under fault and environmental conditions. These assessments ensure the fuses can protect circuits by tripping during events and resetting safely, while maintaining performance over time without . Key tests focus on cycling durability, environmental exposure, fault replication, and parameter validation, often aligned with safety standards such as UL 1434 for thermistor-type devices. Trip and reset cycling involves repeated applications to assess stability and cycle life. Devices are typically subjected to 100 cycles at maximum rated voltage (Vmax) and maximum fault current (), with evaluation for no arcing, burning, or visible damage after each cycle. More rigorous protocols include 50 cycles at 120% of followed by 6000 cycles at 300% of the trip current (Itrip), all under Vmax, to verify sustained functionality without degradation. These tests measure post-cycle to ensure it remains within specified limits, typically ±5-10%, indicating the fuse's ability to repeatedly between low- and high- states. Humidity and thermal aging tests examine material degradation under prolonged exposure to elevated temperature and moisture. For humidity aging, the device is placed in an environment of 85°C and 85% relative humidity for 1000 hours, after which resistance variation should not exceed ±5%. Thermal aging follows a similar duration at 85°C without humidity, again targeting resistance stability within ±5% to confirm the polymer's integrity against heat-induced changes. These procedures, often per IEC 60738-1 and IEC 60068-2-78, help predict long-term reliability in harsh operating environments. Fault simulation replicates real-world overload and short-circuit scenarios through and time-to-trip evaluations. Overload tests apply between the trip current (Itrip) and Imax under Vmax for 1000 hours, ensuring no visible damage or failure. Short-circuit simulations involve applying 5 times the hold current () at Vmax and 23°C, measuring the time to reach a tripped state (high ) within the maximum specified duration, such as 1.36 seconds for certain models. These UL 1434-compliant tests verify protective response without arcing or during sustained faults. End-of-life criteria focus on irreversible degradation, particularly when the reset-state resistance exceeds 10 times the initial value, signaling reduced protective efficacy and potential circuit vulnerability. This threshold is assessed post-cycling or aging, where cumulative trips or environmental stress cause permanent polymer expansion, elevating baseline resistance beyond acceptable limits like Rmin to Rmax at 23°C. Failure occurs if the device no longer resets fully or sustains damage, as confirmed by visual inspection and resistance measurements. Datasheet verification confirms key parameters like hold current (Ih), trip current (It), and time to trip (td) across operating temperatures. Ih is validated by applying the rated hold current for 30 minutes at 23°C without tripping. It and td are measured by subjecting the device to 5 times Ih at Vmax and 23°C, ensuring trip within the specified td, such as under 4 hours for It definition. Temperature derating charts guide testing from -40°C to 85°C, adjusting currents proportionally to verify performance; for instance, Ih may derate to 70% at 85°C. These measurements ensure alignment with manufacturer specifications for safe deployment.

References

  1. [1]
    [PDF] PTC Fuses provide compact, resettable protection for electronic ...
    These thermistor-based components protect circuits and downstream components against too much current due to an overload or short circuit fault condition.
  2. [2]
    [PDF] Bourns® Multifuse® Automotive Brochure
    Resettable fuses are manufactured in the form of a conductive plastic, which is comprised of a non-conductive crystalline polymer with highly conductive carbon ...
  3. [3]
    [PDF] Jill 131999 OSTI
    Jun 14, 1999 · When a carbon black composite is used as a resettable fuse, it is electrically in series with the circuit it is protecting. Under normal ...
  4. [4]
    A Comprehensive Guide to Resettable Fuses | RS
    ### Summary of Resettable Fuses (PPTC) from RS Guide
  5. [5]
    None
    ### Summary of PPTC from https://www.mouser.com/pdfDocs/ApplicationsofPPTCinCircuitProtections_en.pdf
  6. [6]
    Unveiling PTC Thermistor Formula in Electronics - DXM
    Nov 12, 2024 · R(T) = R0(1 + α(T - T0) + β(T - T0)2 + ... ) Here, R(T) represents resistance at temperature T , while R0 is the resistance at reference ...What is a PTC Thermistor... · Understanding the PTC...
  7. [7]
    US2258958A - Conductive device - Google Patents
    A high resistance-temperature coemcient conductive device comprising conducting particles, embedded in an insulating material so that adjacent particles are in ...Missing: PTC | Show results with:PTC
  8. [8]
    [PDF] Raychem Circuit Protection Products - Catalog 2010
    This catalog is intended to present application, product, and technical data to assist the user in selecting circuit.
  9. [9]
    US4775778A - PTC compositions and devices comprising them
    Application filed by Raychem Corp. 1985-05-14. Priority to US06/734,414. 1988 ... Corporation PTC compositions containing low molecular weight polymer molecules ...
  10. [10]
  11. [11]
    Resettable Bladed Sold State & Battery Strap PPTC Fuses - Littelfuse
    Find PolySwitch resettable fuses from Littelfuse to use as PPTC overcurrent protection devices in automotive, telecom, and power supply applications.Missing: carbon black encapsulation
  12. [12]
    [PDF] Carbon Black - Polyethylene Composites for PTC Thermistor ... - DTIC
    This large volume expansion of the polymer pulls the conducting filler ... Compositions of interest ranged from 5 to 40 volume percent carbon black. The ...Missing: PPTC | Show results with:PPTC
  13. [13]
    A Comprehensive Guide to Resettable Fuses - element14 Community
    May 10, 2023 · Resettable fuses have a Positive Temperature Coefficient (PTC), which means that a rise in temperature is followed by an increase in resistance.
  14. [14]
    [PDF] PPTC Resettable Fuses - Ermec
    FRX005-60F~FRX040-60F Tin plated copper clad steel, 24 AWG. FRX050-60F~FRX090-60F Tin plated copper, 24 AWG. FRX110-60F~FRX375-60F Tin plated copper, 20 AWG.
  15. [15]
    Polymer Resettable Fuse PPTC - Reliable Circuit Protection - Alibaba
    4.3 332 Polymer resettable fuse pptc offers reliable circuit protection. High-temp SMD options from top suppliers. Perfect for resettable fuses and thermistors.Missing: electrodes | Show results with:electrodes
  16. [16]
    Multifuse® PPTC Resettable Fuses | Bourns® Circuit Protection
    The newest 125 °C polymer PTC devices are particularly developed to give robust and cost-effective protection and reduce short circuits.Missing: encapsulation coating epoxy
  17. [17]
    Surface Mount - PolySwitch® Resettable PPTC Devices - Littelfuse
    The surface mount devices employ polymer positive temperature coefficient technology to protect electronic components and integrated circuits from inrushes of ...
  18. [18]
  19. [19]
    [PDF] Multifuse® Polymer PTC Resettable Fuses - Bourns
    Multifuse® PPTC Resettable Fuses are made from conductive filled polymer. In normal operation, the conductive particles in the polymer form a continuous ...Missing: definition | Show results with:definition
  20. [20]
    [PDF] PPTC Resettable Fuse - Componentes Electrónicos ELCO
    Typical PPTC. Operating Curve. 125OC. Crystalline Polymer. Carbon Black Conductive Chain. Tripped. State. Temperature rise during fault condition. Original.<|control11|><|separator|>
  21. [21]
    Intriguing Facts About Resettable Fuses in Modern Electronics
    Sep 11, 2025 · At the core of a resettable fuse PTC is a non-conductive crystalline organic polymer. This polymer serves as the matrix that holds the ...
  22. [22]
    PPTC Fuses - Circuit Cellar
    Oct 24, 2023 · PPTC fuses can protect electronics from overcurrent conditions with the added advantage of automatically resetting themselves once the fault ...
  23. [23]
    PTC Resettable fuses - Eaton
    They feature a polymer based construction that provides exponentially increasing resistance during fault conditions to form a tripped state which helps protect ...<|control11|><|separator|>
  24. [24]
    PTC Resettable fuse application guidelines - Eaton
    This device has a 0.6 W maximum power dissipation and takes 1.2 seconds to trip at 8 A maximum. The initial resistance is 0.07 Ω that increases to 0.18 Ω in ...Missing: PPTC | Show results with:PPTC
  25. [25]
    [PDF] 1206L Series - Littelfuse
    Feb 26, 2024 · Rtyp = Typical resistance of device in initial (un-soldered) state. R1max = Maximum resistance of device at 20°C measured one hour after ...Missing: fuse | Show results with:fuse<|separator|>
  26. [26]
    None
    ### Key Parameters for MF-RG Series PTC Resettable Fuses
  27. [27]
    [PDF] Multifuse® PTC Resettable Fuses - Bourns
    The electrodes ensure even distribution of power through the device, and provide a surface for leads to be attached or for custom mounting.
  28. [28]
    [PDF] MF-R Series PTC Resettable Fuses - Bourns
    The Time to Trip curves represent typical performance of a device in a simulated application environment. Actual performance in specific customer applications ...
  29. [29]
  30. [30]
    [PDF] PTC THERMISTORS
    a critical temperature, that is referred to as its. “Curie”, switch or transition temperature. As this critical temperature is approached, the devices begin ...<|control11|><|separator|>
  31. [31]
    None
    ### Summary of Resettable PTC Fuse Form Factors
  32. [32]
  33. [33]
  34. [34]
  35. [35]
    Bladed Devices - Fuses & Overcurrent Protection - Littelfuse
    PPTC bladed devices are resettable fuses. They act like resistors, lowering the flow of current as they heat up in response to an overcurrent.Missing: form factor
  36. [36]
    PPTC Resettable Fuse for Telecom Overvoltage Protection - Littelfuse
    Fast-acting · Available with ratings from 60 V dc to 250 V dc · Interrupting ratings of 250 V dc or 600 V dc · Low resistance ratings (e.g., 4–20 Ω, 6–22 Ω) · Very ...
  37. [37]
    AGRF500 - PolySwitch® Resettable PPTC Devices - Littelfuse
    The AGRF Series is a PPTC resettable device designed specifically for the automotive industry. It is a 16V lead-free, radial leaded resettable device.Missing: fuse | Show results with:fuse
  38. [38]
    Radial Leaded - PolySwitch® Resettable PPTC Devices - Littelfuse
    Radial leaded PolySwitch resettable PPTC devices provide overcurrent protection to circuits, wiring harnesses, and printed circuit board components.Missing: axial | Show results with:axial
  39. [39]
  40. [40]
    [PDF] PolySwitch® Resettable PPTCs Line-Voltage-Rated Devices
    They help protect against damage caused by both overcurrent surges and overtemperature faults. They also offer low resistance and are compatibly sized with fuse.
  41. [41]
    USB Circuit Protection Devices - Bourns | DigiKey
    Jun 16, 2015 · Bourns' Multifuse resettable fuses and ChipGuard ESD suppressors are used to protect today's powerful new USB interfaces.
  42. [42]
    Resettable fuses protect battery packs - EE Times
    A resettable strap device, a type of resettable fuse that is used to provide circuit protection in battery packs, connects between the terminals of two ...
  43. [43]
    [PDF] Application Note - Bourns
    MULTIFUSE PPTC protects speakers by shunting current during overcurrent, or by increasing resistance to limit current flow. It can be used with or without a ...Missing: audio equipment
  44. [44]
    AEC-A200 Qualified Automotive Fuses - Littelfuse
    Our AEC-Q200 qualified automotive fuses are engineered to meet the rigorous demands of AEC automotive standards, delivering reliable performance.
  45. [45]
    Resettable Fuses Multifuse PPTC - AEC-Q200 Compliant - Bourns
    The newest 125 °C polymer PTC devices are particularly developed to give robust and cost-effective protection and reduce short circuits.Missing: qualified 32V
  46. [46]
    Comprehensive Guide to Selecting PPTC Resettable Fuses
    Nov 23, 2024 · A guide to choose the right PPTC resettable fuse, considering operating voltage, hold current, and time-to-trip for optimal overcurrent ...Missing: encapsulation coating epoxy ceramic<|control11|><|separator|>
  47. [47]
  48. [48]
    Application of resettable fuses in solar power generation system
    Aug 9, 2024 · Overload protection of the inverter can be achieved with a resettable fuse: When the inverter load is overloaded or short-circuited, it may ...
  49. [49]
    Ensuring Reliable Circuit Protection with IATF 16949 and AEC-Q200 ...
    Oct 15, 2024 · Fuzetec's PPTC resettable fuses meet IATF 16949 and AEC-Q200, ensuring reliable overcurrent protection in automotive, EV, and industrial ...
  50. [50]
    The Difference Between Traditional and Resettable Fuses | Bel
    PTC fuses reset themselves and can continue to protect circuits without the need for replacement, reducing down-time and extending the life of the application.Missing: 1980s 1990s<|control11|><|separator|>
  51. [51]
    Traditional Fuse vs. PPTC Resettable Fuse - Fuzetec Technology
    Nov 23, 2024 · How Do PPTC Resettable Fuses Work? When an overcurrent event occurs, the PPTC material heats up, increasing its resistance and effectively ...
  52. [52]
    Choosing the Right Overcurrent Protection Device for Safe ...
    Sep 10, 2025 · PPTC resettable fuses are ideal for these applications due to their low-voltage ratings, resettable operation, and low cost. A PPTC can be used ...Traditional Fuses · Pptc Resettable Fuses · Efuses (electronic Fuses)
  53. [53]
    None
    ### Limitations of PPTC Resettable Fuses
  54. [54]
    [PDF] FUSE FUNDAMENTALS - Littelfuse
    Comparative opening times for time-delay, fast-acting, and very fast-acting fuses. AMPERE. RATING. FUSE TYPE. OPENING TIME. 500% RATING. 800% RATING 1200% ...
  55. [55]
    Understand average time current curve of a fuse
    Jan 30, 2021 · If the 7A fuse is fed 100A, it will blow in 0.001 seconds. That quantity is found by looking at the scale on the left hand side. Notice that at ...
  56. [56]
    PTC Resettable Fuses Market Predictions and Opportunities 2025 ...
    Rating 4.8 (1,980) May 30, 2025 · Challenges and Restraints in PTC Resettable Fuses. High initial cost: Compared to traditional fuses, PTC resettable fuses can be more expensive, ...<|separator|>
  57. [57]
    [PDF] POLYFUSE® PTC SELECTION GUIDE - Electronics Source
    have “tripped” when it has transitioned from its low resistance state to a high resistance state due to overload current. Protection is accomplished by limiting ...
  58. [58]
    Polyfuse (resettable PTC) lifetime
    Jul 18, 2014 · There is a proposed design that could have a polyfuse tripping many times. Is there any lifetime to these things? Number of resets?
  59. [59]
    The Key Differences Between PTC Fuses and Single-Use Fuses
    Apr 1, 2025 · PTC resettable fuses operate based on a positive temperature coefficient principle. During normal operation, they maintain low resistance, ...Part 1: Understanding PTC... · Part 4: Choosing Between...
  60. [60]
    Resettable PTC Fuse Benefits, Operation and Applications
    Oct 12, 2020 · A PTC fuse is a special fuse that will reset after power is removed from the circuit. It is a temperature-dependent resistor or thermistor whose resistance ...
  61. [61]
    [PDF] Stress Test Qualification for Passive Components
    Mar 20, 2023 · 1.5.2 AEC Certification. There are no "certifications" for AEC-Q200 qualification and there is no certification board run by AEC to qualify ...
  62. [62]
    [PDF] AEC-Q200-004 REV A June 1, 2000 - Automotive Electronics Council
    Jun 1, 2000 · AEC-Q200-004 defines measurement methods for resettable fuses, based on polymeric materials, to compare them against standard performance ...
  63. [63]
    Bourns Expands High Temperature PTC Resettable Fuses
    Jan 15, 2025 · The TÜV certifications also cover certifications for IEC 62319-1 and IEC 60738-1, as well as IEC 60730-1:2013 clause 15, clause 17, and Annex J.
  64. [64]
    None
    ### Summary of Testing Methods and Procedures for PPTC Fuses (KRL Series)