Fact-checked by Grok 2 weeks ago

Volumetric flask

A volumetric flask is a specialized piece of laboratory glassware designed to contain and measure a precise volume of liquid at a specified temperature, typically 20°C, making it essential for accurate quantitative work in chemistry. It features a distinctive pear-shaped, bulbous body with a flat bottom for stability and a long, narrow neck etched with a single graduation mark that indicates the exact calibrated volume, such as 100 mL or 250 mL. Volumetric flasks are widely used for preparing standard solutions of known concentration, performing precise dilutions, and supporting analytical procedures like titrations, where exact volumes are critical to ensure reliable results. Constructed primarily from for its superior resistance and chemical inertness, these flasks maintain their calibration integrity under typical laboratory conditions. They are manufactured to international standards such as ISO 1042 or ASTM E288, with two main classes: Class A for high-precision applications in , offering tolerances as tight as ±0.05%, and Class B for general-purpose use with approximately double the tolerance range. is performed by the manufacturer using gravimetric methods, but users can verify or adjust it by weighing the mass of a liquid like at the mark and applying corrections for enhanced accuracy.

Overview and History

Definition and Purpose

A volumetric flask is a specialized piece of designed to contain a precise volume of liquid at a specified , typically 20°C, featuring a single graduation mark on the neck that indicates the exact volume when the liquid's aligns with it. This design ensures high accuracy in volume measurement, often achieving tolerances of 0.05% or better for high-quality flasks, making it indispensable for quantitative work where even minor variations can affect results. The primary purpose of a volumetric flask is to prepare standard solutions in by dissolving a known of solute and diluting to the precise , enabling accurate concentrations for subsequent analyses. It is also used for diluting samples with known accuracy and ensuring in procedures such as titrations or spectroscopic measurements, where precision to 0.1% or better is critical for reliable . By providing a fixed reference, it supports experiments requiring consistent conditions across replicates or laboratories. The basic principle underlying the volumetric flask's functionality involves calibration that accounts for the thermal expansion coefficients of both the glass and the contained liquid, ensuring the indicated volume is accurate at the standard temperature to minimize errors from factors like reading or . This flask was developed to overcome the limitations of graduated cylinders, which feature multiple marks and offer lower , typically around 1% accuracy, thus providing a more reliable tool for exact volume containment.

Historical Development

The volumetric flask emerged in the mid-19th century as a key tool in the burgeoning field of , particularly in , where precise measurement techniques were advancing rapidly. Karl Friedrich Mohr, a pioneering chemist, is credited with significant contributions to volumetric apparatus, including the development of the volumetric flask alongside his inventions of improved burettes, , and other devices for accurate volume determination. In his 1855 textbook Lehrbuch der chemisch-analytischen Titrimethode, Mohr outlined methods for that relied on standardized glassware, establishing foundational standards for volumetric measurements that influenced practices worldwide. Although the exact inventor of the flask's distinctive pear-shaped design remains unclear, early versions likely evolved from simple blown-glass containers adapted for precise solution preparation during this era of . By the late 19th and early 20th centuries, the volumetric flask gained widespread adoption as manufacturing techniques improved, with patented designs originating in emphasizing durability and accuracy. German glassware set the global benchmark for precision, prompting international comparisons; for instance, post-World War I tests by Britain's National Physical Laboratory confirmed that British-produced flasks could match or surpass German standards in volumetric accuracy. The introduction of in the early marked a pivotal , with Corning Glass Works launching in 1915—a thermally and chemically resistant material that enhanced the flask's reliability for use. This shift from soda-lime to reduced breakage and improved calibration stability, solidifying the flask's role in scientific workflows. World War II exacerbated material shortages for glass production, yet volumetric flasks proved essential in critical applications, such as the mass production of penicillin, underscoring their wartime significance. Postwar standardization efforts accelerated, with the (DIN, founded 1917) developing specifications like DIN 12664 for volumetric glassware in the mid-20th century. Internationally, the (ISO) established norms after 1947, including ISO 1042 (first edition circa 1969, revised 1983) for one-mark flasks, promoting uniform tolerances and calibration methods. By the 1920s, higher-precision Class A flasks—featuring tighter error limits than Class B—were integrated into pharmacopeial requirements, such as those of the (USP), to ensure reliability in pharmaceutical preparations.

Design and Construction

Materials and Shape

Volumetric flasks are primarily constructed from , such as type 3.3 borosilicate, which offers excellent thermal resistance and a low coefficient of linear of approximately $3.3 \times 10^{-6} \, /^\circ\mathrm{C}. This material ensures dimensional stability across temperature variations, making it ideal for precise volume measurements in settings. Alternatives include high-purity quartz glass for applications requiring enhanced high-temperature resistance and chemical inertness with aggressive substances, as well as (LDPE) or (PP) for disposable, chemically resistant versions that avoid breakage risks. The standard shape features a pear-like bulbous body with a flat base for stability on laboratory surfaces, transitioning to a narrow cylindrical that facilitates accurate filling to the calibration mark. This design minimizes liquid hold-up at the bottom and reduces evaporation or effects during measurement, while the overall height varies with capacity to accommodate secure stopper fitting. The pear-shaped form also supports easy mixing by swirling without spilling, as the wide allows motion while the narrow contains the contents. Key structural elements include a joint or plastic stopper, such as or PTFE, to provide a tight against and . The flasks typically have thick, uniform walls for enhanced durability, enabling autoclaving up to 121°C without deformation.

Graduation and Markings

Volumetric flasks feature a single horizontal etched ring on the elongated neck, positioned precisely at the point corresponding to the nominal volume when the bottom of the aligns with it. This mark is typically produced by or similar precision techniques into the surface, often filled with a permanent, chemically resistant or frosted for enhanced visibility against the . The absence of intermediate lines ensures unambiguous volume determination, minimizing errors in precise measurements. These flasks are calibrated according to the standard "to contain" (TC), indicating the volume held up to the mark inclusive of the meniscus. Calibration occurs at a standard reference temperature of 20°C to account for thermal effects on both glass and liquid. To adjust for temperature variations, the actual volume V_{\text{actual}} at temperature T (°C) can be calculated from the nominal volume V_{\text{nominal}} using the formula: V_{\text{actual}} = V_{\text{nominal}} \times [1 + \beta (T - 20)] where \beta is the cubical expansion coefficient of the liquid; for water, this value is approximately 0.00021 /°C at 20°C. Labeling on the flask includes the nominal capacity (e.g., 100 mL), accuracy class (A for higher precision or B for general use), manufacturer identification code, and the temperature (typically 20°C), all permanently inscribed for and with standards like ASTM E288 or ISO 1042. Many manufacturers incorporate color-coding in the etched markings, stoppers, or labels—such as , or red—for rapid size or type identification in busy environments. The process is meticulously controlled to a shallow depth, which prevents wicking of the liquid along the glass surface and ensures the forms accurately at the mark without distortion.

Classification and Types

Accuracy Classes

Volumetric flasks are standardized into accuracy classes to ensure reliable volume measurements for various applications, with Class A providing the highest precision and Class B offering a more economical alternative for less demanding uses. These classifications are defined by international and national standards that specify maximum permissible errors, or tolerances, for the volume contained at a reference of 20°C. The tolerances are expressed as the deviation in milliliters from the nominal capacity, ensuring reproducibility in . Class A volumetric flasks represent the premium accuracy grade, calibrated to the tightest tolerances outlined in ISO 1042, such as ±0.08 mL for a 100 mL flask. These flasks are essential for and research requiring high precision, often featuring individual serial numbers for and accompanying certificates that verify compliance through rigorous testing. In contrast, Class B volumetric flasks adhere to broader tolerances, approximately twice those of Class A— for instance, ±0.16 mL for a 100 mL flask—yet still meet basic requirements, making them suitable for educational settings, routine preparations, and general tasks where cost efficiency is prioritized. Similar classifications exist in other standards, such as DIN EN ISO 1042 in . Certification for both classes ensures adherence to established standards, including ASTM E288 for laboratory glass volumetric flasks and guidelines, which reference Class A tolerances for pharmaceutical applications and mandate weight-and-water volume tests at 20°C to confirm accuracy. The accuracy class system for volumetric flasks was introduced in the early as laboratory standardization advanced, enabling consistent quality across global scientific practices.

Capacity and Volume Variants

Volumetric flasks are available in a wide range of standard capacities to accommodate various needs, from micro-scale experiments requiring as little as 1 to industrial applications handling up to 10 . Common sizes in routine settings include 10 , 25 , 50 , 100 , 250 , 500 , and 1000 , which align with ISO 1042 specifications for one-mark volumetric flasks. Larger capacities, such as 2 to 10 , are typically employed for pilot-scale preparations where greater volumes of solutions are needed. Design adaptations in volumetric flasks vary by capacity to enhance usability and safety. For smaller flasks under 50 mL, features like hexagonal bases or trapezoidal shapes are incorporated to counterbalance the higher center of gravity and prevent tipping during handling. In contrast, larger flasks often include wider bases to improve stability on work surfaces, reducing the risk of spills when filled to capacity. Selection of a volumetric flask's capacity depends on the specific requirements of the being prepared, particularly the desired concentration and scale of . For instance, a 100 mL flask is commonly chosen for diluting titrants to achieve precise molarities in analytical procedures, while a 2 L flask suits the preparation of stock solutions for multiple uses. Since the adoption of the in 1960, capacities have been standardized exclusively in metric volumes, ensuring global consistency in measurements. The stated volumes of volumetric flasks are nominal values, representing the precise capacity at 20°C when the flask is filled to the graduation mark with the prescribed stopper in place to account for any vapor space effects. Accuracy tolerances for these capacities, such as ±0.02 for a 10 mL flask, are defined independently in classification standards.

Usage and Calibration

Preparation and Filling Procedures

To prepare a volumetric flask for use, it must first be thoroughly cleaned to remove any residues that could contaminate the solution. Cleaning involves scrubbing the interior with a phosphate-free laboratory detergent solution, such as a 2% Citronox solution, followed by rinsing with warm tap water and then at least four rinses with distilled deionized water to eliminate traces of detergent and ions. After rinsing, the flask should be dried by air-drying inverted on a rack to allow complete drainage and prevent dust accumulation, as oven drying can cause non-elastic expansion and compromise calibration. All procedures must be conducted at the flask's specified calibration temperature, typically 20°C, to ensure the volume measurement aligns with the graduation mark on the neck. For filling the volumetric flask to prepare a , begin by adding the measured solute—such as a solid or concentrate—directly to the bulbous body using a small to avoid spillage. For hygroscopic solids like , which readily absorb atmospheric moisture and complicate accurate weighing, transfer the solid directly from the balance into the flask to minimize exposure time. Next, add (e.g., ) gradually to approximately half the flask's , using a stirring rod or by swirling to dissolve the solute completely, then continue adding until the liquid level is about 1 cm below the mark. Thoroughly mix the contents by stoppering the flask and inverting it 10-20 times to achieve homogeneity, allowing any undissolved particles to settle. Allow 5-10 minutes for thermal equilibration to before final adjustment, as can generate that affects . Using a dropper or , add the final dropwise to position the bottom of the precisely at the line, avoiding overfilling which can cause expansion errors due to excess liquid and effects. If overfilling occurs, discard the contents and restart the procedure to maintain accuracy. After the final adjustment, stopper the flask and invert it 10-20 times again to ensure uniform distribution throughout the .

Calibration Techniques

Calibration of volumetric flasks primarily employs the gravimetric method to verify the accuracy of the nominal at the etched mark. This involves weighing the clean, dry flask to determine its tare , then filling it to the mark with freshly boiled and cooled at a standard temperature of 20 °C, ensuring no air bubbles are trapped and the is properly aligned at the bottom of the curve. The flask is then reweighed, and the delivered is calculated using the formula V = \frac{m_\text{water}}{\rho_\text{water}}, where m_\text{water} is the of the (difference between filled and empty weights) and \rho_\text{water} is the of at 20 °C, which is 0.9982 g/. This method ensures traceability to primary standards and is detailed in ISO 4787 for testing and calibration procedures. If the measured volume deviates from the nominal value, adjustment techniques may be required, though such modifications are typically performed by specialized manufacturers rather than in routine settings to maintain integrity. For minor inaccuracies, the mark can be adjusted by precise or filing to reposition it slightly, ensuring the volume aligns with gravimetric measurements; however, in laboratory environments, relative is preferred, involving against a certified pycnometer or using weights traceable to national standards for verification without altering the flask. corrections are applied during using the equation \Delta V = V \times \beta \times \Delta T, where \beta is the volumetric coefficient of the (9.9 \times 10^{-6} /^\circ\mathrm{C} for , approximately 3 times the linear coefficient \alpha = 3.3 \times 10^{-6} /^\circ\mathrm{C}), V is the nominal volume, and \Delta T is the deviation from 20 °C, accounting for volumetric expansion of the flask. In regulated laboratories following (GLP) guidelines, Class A volumetric flasks undergo periodic , typically annually, to confirm compliance with accuracy requirements and ensure measurements are traceable to national institutes such as the National Institute of Standards and Technology (NIST). verifies adherence to tolerance limits outlined in ISO 1042, which specify maximum permissible errors based on flask capacity, such as ±0.02 mL for a 10 mL flask. Common sources of error during include entrained air bubbles that reduce the effective volume or errors from improper reading, which can be minimized by using a black background for visibility and repeating measurements for reproducibility.

Variants and Applications

Modifications for Special Uses

Volumetric flasks have been adapted with specialized materials to withstand elevated temperatures in demanding applications, such as chemical reactions requiring heating. High-temperature variants are constructed from glass, which offers superior thermal stability and can endure temperatures up to 1100°C for prolonged use without deformation, making them suitable for precise volume measurements in heated environments. These flasks provide excellent chemical resistance and are often paired with PTFE stoppers to ensure inertness against aggressive reagents during high-heat processes. Thicker versions also serve as temperature-resistant options, capable of handling thermal stresses beyond standard lab conditions while maintaining calibration integrity. For applications involving light-sensitive substances, volumetric flasks are modified with amber or black glass to shield contents from photodegradation, particularly in organic and biological solutions where exposure to UV or visible light can degrade samples. Amber glass variants block ultraviolet and short-wavelength visible light, preventing reactions in photosensitive compounds and ensuring stability during storage and preparation. These modifications are essential for spectroscopy workflows, where UV-protective coatings further enhance light barrier properties without compromising transparency for volume readings. Black glass options provide even greater opacity for highly reactive biological media, minimizing light-induced alterations. Additional modifications address practical needs in specialized lab settings, including disposable plastic versions made from () or (PMP) for single-use applications involving biohazards, reducing contamination risks and eliminating cleaning requirements. These plastic flasks offer good chemical resistance and transparency, with PMP variants achieving Class A or B accuracy tolerances suitable for precise dilutions. Snap-cap designs facilitate quick and secure sealing, ideal for high-throughput workflows, while custom neck configurations, such as wide or beaded necks, enable compatibility with automated dispensers for efficient filling and emptying. Although PMP flasks can withstand autoclaving up to 121°C, exposure may temporarily affect volume accuracy, limiting their use in repeated sterilization scenarios.

Comparisons with Other Glassware

Volumetric flasks differ from graduated cylinders primarily in their precision and intended applications. While volumetric flasks are calibrated for a single, exact with Class A tolerances typically ranging from 0.05% to 0.2% of the nominal capacity, enabling highly accurate solution preparation, graduated cylinders offer variable measurements across a range but with lower accuracy of approximately 0.5% to 1%. Graduated cylinders are suited for approximate measurements or rough estimations in procedures where high precision is not required, such as initial dilutions or transfers, whereas volumetric flasks excel in delivering a fixed for standard solutions. In comparison to s and , volumetric flasks serve bulk preparation rather than precise dispensing. Burettes allow for the controlled delivery of variable volumes, often in 0.01 mL increments, making them ideal for titrations where incremental additions are necessary, with accuracies comparable to or exceeding 0.03 mL for a 25 mL Class A burette. Pipettes, particularly volumetric ones, are designed for transferring fixed small volumes with high precision, typically less than 0.2% tolerance, but are limited to smaller quantities than flasks. Unlike these dispensing tools, volumetric flasks do not facilitate direct pouring or measurement during reactions, focusing instead on containing a known total volume for dilutions or standards. The primary advantage of volumetric flasks lies in their superior suitability for exact dilutions and quantitative analyses, where maintaining a precise overall is critical, outperforming the multi-point but less accurate readings of cylinders or the limited of . However, they present disadvantages such as increased fragility compared to more robust cylinders, requiring careful handling to avoid breakage, and longer preparation times—often involving gradual filling to the mark and thorough mixing—versus the rapid transfer possible with . Safety considerations highlight the risks associated with volumetric flasks relative to other glassware. Due to their thin necks and precise , they are prone to breakage under , such as direct heating, unlike sturdier cylinders; laboratory protocols mandate the use of protective gloves and eye gear during handling to mitigate injury from shards. Material compatibility is also key: standard borosilicate provides resistance to most acids and moderate bases, but non-borosilicate variants may degrade with strong bases, emphasizing the need for borosilicate models in chemical work.

References

  1. [1]
    Volumetric Flask: Description
    A volumetric flask is used to measure very precisely one specific volume of liquid (100 mL, 250 mL, etc., depending on which flask you use).Missing: definition | Show results with:definition
  2. [2]
    Volumetric Flask: Types, Uses & Measurement Tips for Labs
    Ans - A volumetric flask has a calibrated mark that indicates a specific volume, making it ideal for accurate liquid volume measurements. A general-purpose lab ...
  3. [3]
    Appendix C Measurement of liquids - lab_append
    Volumetric flasks: used to obtain precise volume measurements. A high quality volumetric flask can have an accuracy of plus or minus 0.05%. They are normally ...Missing: definition | Show results with:definition
  4. [4]
    Volumetric Flasks | DWK Life Sciences
    What are the volumetric flask standards? ... Both standards define two classes of accuracy (Class A and B), with Class B having twice the tolerance of Class A.
  5. [5]
    [PDF] Selected Procedures for Volumetric Calibrations (2019 Ed)
    The calibration procedures for Small Volume Provers (SOP 26, Volumetric, and SOP-. SVP, Gravimetric) were revised and replaced SOP 26 for generic “Gravimetric.
  6. [6]
    [PDF] Calibration of Volumetric Glassware
    Volumetric flasks (Vol. Flask) are designed to contain the indicated volume of liquid. The burets and pipets (Vol. pipet) used in this laboratory are designed ...
  7. [7]
    [PDF] CHEM 334 Quantitative Analysis Laboratory
    Oct 29, 2018 · The volumetric flask is used to prepare Standard Solutions or in diluting a sample. Most of these flasks are calibrated To-Contain (TC) a given ...
  8. [8]
    Glassware - Volumetrics
    Volumetric glassware or volumetric flasks are containers that have been calibrated to a specific volume. These flasks, unlike Erlinmeyer flasks or beakers, are ...
  9. [9]
    [PDF] Lab 1- Analytical glassware and measurements
    Volumetric flasks for making stock solutions: widely used to prepare stock solutions, typically requires pipetting some volume of liquid (using a manual or.
  10. [10]
    Measuring Volume of Liquids - Harper College
    Some chemistry glassware, called volumetric glassware, is inscribed with markings to make measuring the volume of liquids easier.Missing: definition | Show results with:definition
  11. [11]
    Karl Friedrich Mohr, 1806-1879 Father of Volumetric Analysis" - jstor
    Liebig condenser was improved and popularized by that famous chemist, but was invented by his friend Mohr. How many realize that.Missing: Carl | Show results with:Carl
  12. [12]
    Volumetric Flask - Guide to Value, Marks, History - WorthPoint
    The characteristic teardrop shape became the standard closer to the turn of the 20th century.
  13. [13]
    A Comparison of British and German Volumetric Glassware - Nature
    THE manufacture of volumetric glassware was practically non-existent in this country prior to the war. During and since the war it has been developed on an ...
  14. [14]
    PYREX vs. Pyrex: What's the Difference? - Corning
    In fact, these scientific glassware products were integral in developing penicillin during World War II and the polio vaccine during the 1950s. Corning ...
  15. [15]
    [PDF] Volumetric Glassware - Reagecon Knowledge
    There are DIN Class A and Class B standards for measuring cylinders. ♢ The USP Class A standard has much tighter specifications than the DIN Class A tolerances.
  16. [16]
    What is Borosilicate Glass? | Composition & Types Explained
    3.3 borosilicate glass has the lowest coefficient of thermal expansion which is 3.3 x 10-6K-1. It is highly resistant to most chemicals, except for hydrofluoric ...
  17. [17]
    Physical Properties of Borosilicate Glass 3.3
    Physical Properties of Borosilicate Glass 3.3 ; Mean linear thermal expansion coefficient, a 20/300, = (3,3 ± 0,1) x 10-6 K-1 ; Mean thermal conductivity between ...
  18. [18]
  19. [19]
    Volumetric Flask Material Selection - Glass And Plastic - Blogs - News
    Apr 3, 2025 · Plastic volumetric flasks are typically made from polyethylene (PE), polypropylene (PP), or polytetrafluoroethylene (PTFE). As laboratory needs ...Missing: quartz | Show results with:quartz
  20. [20]
    Volumetric Flasks Accuracy and Precision in Labware - Cole-Parmer
    Oct 31, 2023 · Volumetric flasks undergo rigorous individual calibration, guaranteeing a minimal margin of error in their volume capacity. With a single ...
  21. [21]
    A Visual Guide to Chemistry Glassware - Compound Interest
    Mar 17, 2015 · ... narrow neck of the volumetric flask will have a thin graduation to show where a specific volume is reached. Round-bottomed flasks and ...
  22. [22]
    FLASKS, VOLUMETRIC, CLASS A, GLASS STOPPERS
    Ground Joints · Rodaviss Joints · Spherical Joints · Ground Flanges · O-Ring Flanges ... 5mL Volumetric Flask, Class A, #9 Outer Stopper Neck, Glass Stopper.
  23. [23]
  24. [24]
    EISCO Premium Volumetric Flask Set - 50ml, 100ml & 250ml
    Microwavable and autoclavable, with superior chemical durability. Low temperature gradient- can withstand high temperatures & thermal shocks. Eisco Labs ...
  25. [25]
    Volumetric flask - Sciencemadness Wiki
    May 5, 2018 · The neck of the volumetric flasks is elongated and narrow with an etched ring graduation marking. The marking indicates the volume of liquid ...
  26. [26]
    Volumetric Flasks - Fisher Scientific
    Volumetric flasks, also called graduated flasks or measuring flasks, are items of laboratory glassware or plasticware calibrated and labelled to contain a ...Missing: alternatives quartz
  27. [27]
  28. [28]
    1.1: Analytical Lab Equiptment - Chemistry LibreTexts
    Jun 18, 2025 · Volumetric Flask. A volumetric flask is calibrated to contain (T.C.) or to deliver (T.D.) a specific volume of solution at room temperature ...Equipment for Measuring and... · Transfer Pipet · Volumetric Pipet · Volumetric Flask
  29. [29]
    Understanding “TD” And “TC” in Laboratory Glassware - Blogs - News
    May 27, 2025 · Laboratory glassware often bears markings such as “TD” (To Deliver) or “TC” (To Contain), which represent different calibration standards.
  30. [30]
    Volumetric (Cubic) Thermal Expansion - The Engineering ToolBox
    The volumetric coefficient for water is negative below 4 oC and indicates that the a volume decreases when temperature moves from 0 oC ( 32 oF) to 4 oC. Example ...
  31. [31]
    Volumetric Flask Definition in Chemistry - ThoughtCo
    Aug 4, 2018 · It should be noted volumetric flasks are calibrated for a particular temperature (usually 20 °C), which is indicated on the label. ... A Class B ...
  32. [32]
    KIMBLE® KIMAX® Colorware Volumetric Flask, Class A, Pink, 100 mL
    In stockColor coding for easy identification, 5 different colors available; Single graduation ring is calibrated "To Contain"; Glass stopper included, along with a ...
  33. [33]
    E288 Standard Specification for Laboratory Glass Volumetric Flasks
    Jul 15, 2025 · 1.1 This specification covers requirements for glass volumetric flasks of precision and general-purpose grades suitable for laboratory purposes.
  34. [34]
    Class A Volumetric Flask 10L ST38 Stopper - SP Wilmad
    Calibrated to contain at 20° C. Flask sizes comply with requirements for Type 1, Class A “Unserialized flasks.” Supplied with a penny head stopper.
  35. [35]
    ISO 1042:1998(en), Laboratory glassware — One-mark volumetric ...
    ISO 1042 specifies requirements for one-mark volumetric flasks for general lab use, including narrow-necked and wider-neck options, and material specifications.Missing: post- 1950s
  36. [36]
  37. [37]
    2mL Micro Volumetric Flask, | 5630-2-CL | Corning Glass
    In stock $41.63 deliveryThey are designed for microchemical work. To improve the stability of this small flask, a hexagonal base, similar to those on all cylinders, has been added.
  38. [38]
    Volumetric Flasks | Measuring Flasks - BRANDTECH Scientific
    Trapezoidal volumetric flasks: Small capacity standard volumetric flasks can tip over more easily due to their higher center of gravity.Missing: shorter | Show results with:shorter
  39. [39]
    [PDF] Volumetric Flasks - BOROSIL
    Trapezoidal volumetric flasks have much larger base area which ensures higher stability. It has atleast twice base area compare to standard volumetric flask of.Missing: stoppered unstoppered
  40. [40]
  41. [41]
    Metric System Conversions | Biology I Laboratory Manual
    In 1960 the metric system became the basis for the International System of Units (SI units). The basic units of these measurements for the metric system are ...
  42. [42]
    [PDF] specification for working standards of capacity glass volumetric flasks
    2. The capacity of a flask is the volume of water it contains at 20 ºC when the lowest part of the meniscus is tangential to the top of the graduation line, the ...
  43. [43]
    None
    ### Summary of Cleaning Volumetric Flasks, Rinsing, and Drying Methods to Avoid Contamination
  44. [44]
    [PDF] Fundamental Laboratory Techniques for Quantitative Chemistry
    Next, we will transfer the weighing paper from the balance to a 500 milliliter volumetric flask, which is the volume of one-tenth molar sodium hydroxide that we ...
  45. [45]
    [PDF] Experiment 2 – Simulation – Standardization of an NaOH Solution ...
    For example, solid sodium hydroxide (NaOH) is hygroscopic, meaning it absorbs moisture from the atmosphere, and therefore it is difficult to weigh accurately.
  46. [46]
    [PDF] MITOCW | MIT Digital Lab Techniques Manual
    Volumetric flasks are used to dilute solutions. What would we need for this process? The flask, powder or concentrated solution instead, a funnel and stirring ...
  47. [47]
    [PDF] Chemistry Lab Technique 6: Using a Volumetric Flask
    A volumetric flask is a piece of glassware calibrated to contain a precise volume at a particular temperature. It is used in the laboratory to prepare ...
  48. [48]
    Water Density, Specific Weight and Thermal Expansion Coefficients
    Water density at temperature 20 oC is 998.21 kg/m3(table above). The density ... Figures and tables showing specific gravity of liquid water in the range of 32 to ...
  49. [49]
    [PDF] Selected Procedures for Volumetric Calibrations (2017 Edition)
    May 15, 2019 · This procedure is a precision mass calibration converting mass values to volumetric values using pure water as a standard reference material.
  50. [50]
    Properties of Borosilicate Glass - AZoM
    Borosilicate glass is chemically resistant, has a low thermal expansion coefficient and can be used at relatively high temperatures.
  51. [51]
    Calibration of Volumetric Glassware used in Pharmaceuticals
    Weigh a clean & dry volumetric flask. Calibrate the flask by filling it with recently boiled and cooled distilled water at room temperature up to the mark ...
  52. [52]
    High Temp Resistant Quartz Flask 50ml-1000ml, Laboratory ... - eBay
    In stock Free deliveryCrafted from premium quartz material, this flask ensures exceptional durability and high temperature resistance, making it perfect for various laboratory ...
  53. [53]
    QWORK 500ml Volumetric Flask with Glass Stopper, 2 Pack 3.3 ...
    Premium and Durable. The volumetric flask made of borosilicate glass, thick material, high temperature resistance, acid and alkali resistance.Missing: quartz | Show results with:quartz
  54. [54]
    KIMBLE® RAY-SORB® Volumetric Flask, Amber, Class A, Heavy ...
    UV protection due to external colouration; amber (RAY-SORB®) processed to protect light-sensitive contents from short-length light waves. Less than 1 ...Missing: photodegradation | Show results with:photodegradation
  55. [55]
  56. [56]
    AMBER FLASKS - POBEL
    Amber glass blocks ultraviolet and visible light, protecting sensitive liquids from photodegradation, ensuring their stability during storage and procedures.
  57. [57]
  58. [58]
    Corning® Volumetric Flasks, PMP, Class A
    Translucent flask is supplied with tapered polypropylene stopper with an individually calibrated graduation line. The product is manufactured to Class A ...Missing: biohazards snap- cap custom necks
  59. [59]
  60. [60]
    Nalgene Class B Polymethypentene (PMP) Volumetric Flasks with ...
    Warning: Autoclavable but accuracy will be affected. Completely disengage threads or remove cap before autoclaving ...
  61. [61]
    Volumetric Glassware - WebAssign
    All volumetric glassware is calibrated with markings used to determine a specific volume of liquid to varying degrees of accuracy. To read this volume exactly, ...
  62. [62]
    [PDF] Calibration of Burets and Pipets - CSUN
    According to the National Institute of Standards and Technology (NIST), the error of a 25-mL. Class A buret should not exceed 0.03 mL, i.e., the allowable ...