Fact-checked by Grok 2 weeks ago

Antistatic agent

An is a or additive incorporated into materials, particularly polymers and textiles, to reduce or eliminate the accumulation of on their surfaces by enhancing electrical and dissipating charges. These agents are essential in preventing hazards such as dust attraction, sparks, or material adhesion in industrial and consumer applications. Antistatic agents are broadly classified into internal types, which are mixed into the during , and external types, applied topically to . Common categories include hygroscopic agents that attract moisture to form a conductive layer, such as or inorganic salts like ; ionic agents, including cationic (e.g., alkyl quaternary ammonium salts) and anionic types (e.g., sulfate esters); and conductive fillers like or carbon nanotubes for permanent conductivity. Nonionic and silicones, such as dimethicone, are also used, particularly in formulations requiring compatibility with sensitive materials. The mechanisms of antistatic agents primarily involve increasing surface or volume through hydrophilic groups that absorb atmospheric , thereby lowering electrical , or by providing mobile ions for charge . In polymers, they migrate to the surface to form a thin conductive , reducing surface resistivity to levels like 10⁵–10¹² ohms/square for (ESD) protection, with effectiveness often depending on (e.g., less reliable below 45% relative humidity for certain phosphates). Some agents, like conductive polymers or fillers, achieve this by altering the bulk material properties rather than surface migration. Antistatic agents find widespread applications in industries such as for ESD-safe packaging and components, automotive and for static-free interiors, and healthcare for non-dusting devices. In consumer products, they are used in textiles to prevent clinging, in like shampoos to reduce hair , and in to avoid contamination from static-attracted particles, often requiring compliance with regulations for indirect contact. Additionally, they mitigate risks in , , and production by preventing electrostatic discharges that could ignite flammable substances.

Fundamentals

Definition

Antistatic agents are chemical compounds or formulations designed to treat materials or their surfaces in order to reduce or eliminate the buildup of . These substances are commonly incorporated into polymers, textiles, and other insulators to mitigate the accumulation of electrostatic charges that can arise from friction, contact, or separation of materials. The primary purpose of antistatic agents is to prevent practical problems associated with , such as the attraction of dust and , unwanted between materials, uncomfortable electric shocks to users, and potential or damage to sensitive electronic equipment. By addressing these issues, antistatic agents enhance safety, improve handling and processing efficiency, and extend the usability of treated products in various industrial and consumer settings. In terms of basic properties, antistatic agents are typically hygroscopic, conductive, or lubricating materials that function by lowering the surface resistivity of the treated material, thereby facilitating the dissipation of static charges. This resistivity reduction allows charges to flow away more readily, often through the absorption of ambient or direct . Antistatic agents were first developed in the mid-20th century, particularly during the , to address static-related challenges in emerging applications like plastics and textiles . Their widespread adoption accelerated in the post-1950s era as production scales grew and the need for reliable static control became evident in sectors such as and .

Mechanism of action

Static electricity arises primarily through triboelectric charging, a process in which electrons are transferred between two materials during contact or friction, resulting in an accumulation of charge on their surfaces. This charge buildup occurs because insulating materials, such as polymers, do not readily conduct electrons away, leading to potential differences that can cause electrostatic discharge. Antistatic agents counteract this by employing several primary mechanisms to dissipate charges and prevent accumulation. Hygroscopic action involves the agent absorbing atmospheric moisture to form a thin conductive layer on the material surface, which facilitates charge leakage. Ionic conduction relies on the migration of ions from the agent to the surface, where they neutralize accumulated charges by providing a pathway for flow. Additionally, lubricity reduces inter-material during contact, thereby minimizing the initial generation of triboelectric charges. These mechanisms collectively lower the surface resistivity of the material, transitioning it from an insulating state (>10^{12} \Omega / \square) to the antistatic (10^{5} to 10^{12} \Omega / \square), allowing static charges to dissipate safely without sparking. The efficacy of antistatic agents is influenced by environmental and material factors, including levels, which enhance hygroscopic and ionic effects by increasing available ; , which affects agent and ; and material , which determines how well the agent integrates and performs within the host .

Types

Internal antistatic agents

Internal antistatic agents are chemical compounds incorporated directly into the bulk of polymeric materials during manufacturing processes such as , , or injection molding, enabling permanent integration within the matrix to provide sustained static charge . These agents function by either migrating to the surface to form a hygroscopic layer that absorbs atmospheric for or by creating a fixed conductive network throughout the material, thereby reducing surface resistivity over time. Common examples of internal antistatic agents include ethoxylated amines, (GMS), and quaternary ammonium compounds, which are widely used in thermoplastics like and . Other variants encompass non-ionic such as ethoxylated amines and anionic salts, selected based on the polymer's and processing conditions. The primary advantages of internal antistatic agents lie in their ability to deliver long-lasting protection against static buildup, ensuring within the material without the need for post-processing applications, which enhances durability in end products. They also minimize migration-related inconsistencies over the 's lifecycle, particularly for non-migrating types, and can maintain efficacy across a range of levels when properly formulated. However, these agents can present disadvantages, such as potential impacts on the mechanical properties of the , including reduced clarity or tensile strength, especially at higher loading levels of 1-5% by weight. Additionally, migratory types may require elevated processing temperatures and can lose effectiveness in low-humidity environments below 45% relative humidity, while non-migratory fillers like often demand higher concentrations that increase material costs. Specific formulations distinguish between migrating and non-migrating internal antistatic agents to suit different applications; migrating types, such as GMS or low-molecular-weight ethoxylated amines, gradually bloom to to attract for charge dissipation, ideal for flexible films but prone to depletion over time. In contrast, non-migrating formulations employ inert conductive fillers like or metallic fibers, which form a stable percolating network for humidity-independent performance in durable goods, though they may alter the material's or require loadings up to 20% for optimal resistivity below 10^9 ohms per square.

External antistatic agents

External antistatic agents are surface-active ionic or nonionic compounds applied topically to the surface of materials after manufacturing to form a thin conductive layer that dissipates static charges. These agents are typically delivered in aqueous or alcoholic solutions and adhere to the substrate to increase surface conductivity, thereby reducing electrostatic buildup without penetrating the bulk material. Common application methods include spraying, dipping (immersion), wiping, or coating, often at concentrations of 1–2% to achieve uniform coverage. For instance, electrostatic spraying can ensure even distribution on complex shapes, while immersion techniques are suitable for batch processing of items like plastic components. Typical examples of external antistatic agents include cationic types such as quaternary ammonium salts (e.g., dimethyl dihydrogenated tallow ammonium ) and phosphonium salts, anionic types like phosphate esters and sulfonates, as well as nonionic options such as polyglycol ethers. These are often formulated as clear or lightly colored liquids that dry to a hygroscopic , attracting ambient to facilitate charge leakage. A key advantage of external antistatic agents is their quick and straightforward application, providing immediate static protection without altering the or properties of the underlying material, making them ideal for retrofitting existing products. They are cost-effective for short-term needs, such as preventing during handling or storage, and can significantly lower surface resistivity—for example, to around 10^9 Ω with proper dilution and application. However, these agents offer only temporary effects, typically lasting weeks to months before wearing off due to , , or washing, necessitating periodic reapplication. Uneven coverage can occur if application techniques are not , potentially leading to inconsistent antistatic performance across the surface. Despite their limitations, external agents remain valuable for applications requiring flexible, non-permanent static .

Applications

In polymers and plastics

Antistatic agents play a crucial role in and processing by dissipating static charges generated during , injection molding, and handling, thereby preventing defects such as material clinging, dust attraction, and potential sparking that could lead to fires or equipment damage. In end-products, these agents ensure long-term charge dissipation to maintain functionality and safety, particularly in environments where static buildup could compromise performance. These agents are commonly applied to specific polymers including (PE), (PP), (PVC), and (PS), where static issues are prevalent due to their low surface conductivity. For instance, in PP films and sheets, internal antistatic agents like glycerol monostearate (GMS) are incorporated at loadings of 0.5-2% to achieve surface resistivity in the range of 10^5 to 10^12 ohms, enabling effective charge dissipation. External antistatic agents, such as ethoxylated amines or quaternary ammonium compounds, are preferred for temporary protection during assembly of PVC or components, as they form a conductive surface layer without altering the bulk polymer properties. Internal agents provide permanent integration into the polymer matrix, while external ones offer short-term effects during manufacturing. Key challenges in their use include balancing antistatic efficacy with optical transparency and mechanical integrity in clear polymers like , as well as ensuring compatibility with recycling processes in and . Additionally, low-molecular-weight agents like GMS can migrate to the surface over time, with performance varying in humid environments where moisture absorption enhances conductivity but may lead to blooming or reduced durability. In industry applications, antistatic agents are essential for packaging films made from and , where they reduce accumulation and improve printability, and for automotive parts such as interior components from PVC, minimizing static-related and .

In textiles and fibers

Antistatic agents play a crucial role in textile production and use by mitigating buildup in synthetic fibers such as , , and , which are inherently prone to charge accumulation due to their low moisture absorption properties. These agents reduce static cling during key processes like spinning, , and garment assembly, preventing issues such as fiber , yarn breakage, and attraction that can disrupt manufacturing efficiency. In wearable items, they minimize , ensuring safer handling in environments sensitive to . Application methods for antistatic agents in textiles include internal incorporation and external finishing. Internal agents are doped into the melt during extrusion, allowing even distribution throughout the for long-lasting effects, particularly suited for synthetic yarns like and . External agents, often applied as topical finishes, are introduced via or processes, where fabrics are immersed in solutions containing quaternary ammonium salts or other and then dried to form a conductive surface layer. These methods can be combined for optimal performance in blended fibers. The benefits of antistatic agents extend to improved fabric quality and . By neutralizing charges, they prevent pilling and clumping caused by static-induced particle attraction, enhancing durability during wear and laundering. They also improve uptake by increasing surface hydrophilicity, leading to more uniform coloration in synthetic textiles. For , these agents enhance comfort by reducing static shocks and clinginess, promoting better and contact without . Historically, antistatic agents saw early adoption in the for carpet fibers, coinciding with the rise of synthetic materials like , to address static-related soiling and wear issues in household applications. Modern advancements include carbon-infused yarns, where carbon nanotubes or are integrated into fiber matrices to achieve enhanced conductivity while maintaining flexibility for apparel and . These developments build on traditional agents by offering permanent antistatic properties without relying on humidity. Performance in antistatic textiles is typically evaluated by surface resistivity, with effective apparel achieving values around 10^{10} / \mathrm{sq} to ensure controlled charge without excessive . This allows fabrics to meet standards for electrostatic protective , balancing static with wearability across varying environmental conditions.

In fuels

Antistatic agents serve a critical role in fuels, including , , and , by enhancing to prevent the accumulation of static charges during pumping, transportation, and storage, which could otherwise produce sparks capable of igniting volatile vapors and causing explosions. These additives are particularly essential in high-flow scenarios, such as refueling or loading tankers, where between fuel and pipes generates electrostatic charges. In , static dissipator additives are commonly used and required by some specifications, such as DEF STAN 91-91 for Jet A-1 fuels to meet requirements under standards like ASTM D1655, while optional for Jet A. They are also employed in and to enhance during handling. In , static dissipator additives are mandated by standards like ASTM D1655 for Jet A and Jet A-1 fuels to ensure safe handling, with similar requirements applying to and to mitigate fire hazards. The primary types of antistatic agents used in fuels are ionic compounds, such as long-chain alkyl sulfonic acids like dinonylnaphthalene sulfonic acid (DNNSA), which are oil-soluble and effective at low concentrations typically ranging from 0.5 to 3 ppm, with a maximum cumulative concentration of 5 ppm depending on the specification and fuel composition. Commercial examples include Stadis 450, a proprietary formulation approved for aviation turbine fuels under ASTM D1655 and other international specifications. For diesel and gasoline, similar ionic additives like Stadis 425 are employed to achieve comparable conductivity improvements without affecting fuel performance. In untreated fuels, electrical is inherently low, often below 1 pS/m (picoSiemens per meter), allowing charges to build up rapidly; antistatic agents increase this to at least 50 pS/m—typically 50 to 450 pS/m—to enable quick dissipation of charges through the and grounded equipment, thus preventing spark generation. This mechanism does not eliminate charge formation but ensures charges relax within milliseconds, aligning with safety protocols measured by ASTM D2624. The use of antistatic additives in fuels became mandated in the mid-20th century following a series of explosions linked to static ignition, with widespread adoption in jet fuels dating back to the to address hazards in and handling. Regulatory evolution, including ASTM D1655 specifications introduced in the and refined over decades, has since required these additives in international Jet A-1 fuels and recommended them for and to enhance overall in storage and transfer operations.

In electronics and packaging

Antistatic agents play a critical role in manufacturing by protecting sensitive circuits from (ESD) during assembly, handling, and transportation, thereby preventing damage that could lead to device failure. These agents are integral to ESD control programs that adhere to industry standards such as ANSI/ESD S20.20, which provides guidelines for developing comprehensive ESD protection measures, including the use of dissipative materials and grounding protocols to limit charge buildup and discharge events. In high-precision environments, antistatic treatments ensure that static charges dissipate slowly and safely, avoiding the rapid discharges that can exceed 10 kV and damage components like integrated circuits. Specific applications of antistatic agents in and include protective enclosures such as bags, trays, and mats designed for semiconductors and other ESD-sensitive items. Antistatic bags, often featuring metallized layers or conductive polymers, create a effect to shield contents from external electrostatic fields during storage and shipping. Similarly, trays and mats used in assembly lines incorporate antistatic formulations to provide a controlled path for charge dissipation, while conductive coatings applied to printed circuit boards (PCBs) enhance surface protection against ESD during and testing processes. These materials are essential in maintaining the integrity of delicate components, such as microchips, where even minor ESD events can cause latent defects. Antistatic agents are integrated into through both internal and external methods to achieve reliable protection. Internally, conductive fillers like or metallic particles are compounded into plastics during or molding, forming percolating networks that enable charge dissipation without compromising mechanical properties. , for instance, is widely used due to its ability to lower resistivity at low loading levels, typically 10-20% by weight, making it suitable for trays and housings. Externally, topical sprays containing quaternary compounds or other are applied to workstations, tools, and surfaces to temporarily reduce surface resistivity and prevent static accumulation. Performance requirements for antistatic materials in emphasize tuned surface resistivity in the range of $10^6 to $10^9 ohms per square, which provides dissipative protection by allowing controlled charge flow without rendering the material fully conductive and risking short circuits. This range ensures compliance with ESD standards, where materials below $10^5 ohms/sq are classified as conductive and those above $10^{12} ohms/sq as insulative, potentially hazardous for ESD-sensitive applications. In cleanroom environments for integrated circuit (IC) manufacturing, antistatic agents have demonstrated significant impact through case studies showing reduced yield losses from ESD events. For example, implementing ESD control measures, including antistatic flooring and packaging, has been linked to preventing up to one-third of PCB failures in semiconductor production, where ESD can cause immediate or latent damage leading to batch rejections and financial losses estimated in millions annually. Such applications in facilities like those producing advanced nodes (e.g., 5 nm processes) highlight how dissipative materials minimize defect rates, improving overall manufacturing efficiency.

Safety and environmental considerations

Health and safety

Antistatic agents, particularly those based on quaternary ammonium compounds (QACs), can pose health risks primarily through dermal, respiratory, and ocular exposure. QACs are known to cause and , with repeated or high-concentration exposures leading to severe burns or persistent . In spray formulations, of mists or vapors may result in , , or, in chronic cases, links to development. For applications, certain antistatic finishes incorporating QACs or ethoxylates (NPEs) have been associated with , manifesting as red, irritated in sensitive individuals. Occupational safety guidelines emphasize minimizing exposure through , ventilation, and (PPE). Workers handling antistatic agents should wear chemical-resistant gloves, such as or , to prevent dermal , along with and respiratory masks in areas with generation. For amine-based antistatic agents, such as ethoxylated alkylamines, adherence to NIOSH recommended exposure limits (RELs) for related amines is recommended; for example, the REL for , a common component, is 3 ppm (15 mg/m³) as an 8-hour time-weighted average with skin notation. Proper training on safe handling, including avoiding direct contact and ensuring adequate airflow, is essential to reduce risks during application or processing. Most antistatic agents exhibit low profiles, making them suitable for widespread industrial use, though specific compounds vary. (GMS), a common non-ionic antistatic agent, has an oral LD50 greater than 5 g/kg in rats, indicating low , and is (GRAS) by the FDA for food contact applications. QACs generally show low systemic at typical exposure levels but can cause localized . Certain other antistatic agents, such as nonylphenol ethoxylates (NPEs), may exhibit mild potential in biological systems, raising concerns for prolonged exposure. Overall, these agents are considered low-risk when used as directed, with primarily linked to concentrated forms. In case of exposure, immediate measures include flushing affected skin or eyes with copious amounts of water for at least 15 minutes to dilute and remove the , followed by seeking medical attention if irritation persists. For inhalation, move the individual to fresh air and administer oxygen if is difficult; ingestion requires rinsing the and avoiding induced . Spill response involves containing the material with absorbent pads to prevent slips on wet surfaces and ignition sources if the is flammable, followed by ventilation and cleanup using non-sparking tools. Always consult the product's (SDS) for tailored emergency procedures.

Environmental impact

Antistatic agents, particularly non-biodegradable types such as fluorinated compounds, pose environmental risks due to their persistence and potential for in ecosystems. Fluorinated antistatic agents, often used in textiles and coatings, exhibit high persistence in the , with factors that allow them to concentrate in organisms and biomagnify through food chains, leading to widespread in bodies and sediments. Additionally, external antistatic agents applied to textiles can leach into waterways during washing and industrial processing, contributing to pollution as these migrate from fabrics into systems. Many internal antistatic agents, such as esters, demonstrate favorable biodegradability profiles under standardized testing. For instance, mixed esters of (C8-18 and C18-unsaturated) with achieve greater than 60% degradation within 28 days in the OECD 301B CO2 evolution test, qualifying them as readily biodegradable and reducing long-term environmental accumulation. Regulatory frameworks address these concerns by imposing restrictions on certain antistatic agents to minimize ecological harm. In the , the REACH limits the use of specific quaternary ammonium compounds—common in antistatic formulations—due to their persistence and potential toxicity, particularly in consumer products like textiles. Similarly, the U.S. Environmental Protection Agency requires registration and environmental impact assessments for antistatic additives in fuels under 40 CFR Part 79, ensuring compliance with standards for aquatic toxicity and to prevent releases during handling and combustion. As of November 2025, additional developments include the EU's updated PFAS restriction proposal (published August 2025) targeting non-essential uses of (PFAS) in applications like textiles, and U.S. state-level actions such as Minnesota's ban on intentionally added PFAS in consumer products effective January 1, 2025. To mitigate these impacts, industry trends favor shifting to bio-based antistatic agents derived from renewable sources, such as vegetable-derived , which offer reduced persistence and enhanced biodegradability compared to synthetic alternatives. These plant-based esters, sourced from oils like soy or palm, lower the overall by breaking down more readily in natural environments while maintaining antistatic efficacy in polymers and textiles.

References

  1. [1]
    Antistatic Agent - an overview | ScienceDirect Topics
    Antistatic agents refer to additives used in polymers to prevent the buildup of static electricity, often by enhancing the surface conductivity. They can ...Missing: credible | Show results with:credible
  2. [2]
    Antistatic agents - ChemicalBook
    Antistatic agents refer to the chemical reagents capable of increasing the dielectric surface conductivity and volume conductivity to prevent static ...
  3. [3]
    Anti-static agents: How to select the right grade for plastics?
    Jun 30, 2025 · Anti-static agents are used to either manage static charges during various stages of processing or to provide long-term static protection ...Missing: credible | Show results with:credible
  4. [4]
    Antistatic Agent - an overview | ScienceDirect Topics
    Most antistatic agents, therefore, function by ensuring the presence of a surface water layer; they are hygroscopic compounds and are frequently electrolytes.
  5. [5]
    A Brief Evaluation of Antioxidants, Antistatics, and Plasticizers ... - NIH
    Antistatic agents (or antistats) are added to polymers to concede some electrical conductivity to avoid or minimize the accumulation of electric charges in the ...2. Antioxidants (aos) · 3. Antistatic Agents · 4. PlasticizersMissing: historical | Show results with:historical
  6. [6]
    Antistatic agent - MFA Cameo
    Jun 16, 2023 · Antistatic agents, developed in the 1950s, are typically hygroscopic and thus attract moisture that dissipates the charge.Missing: mid- century
  7. [7]
    Controlling Static Electricity: A 50-Year History - ESD Association
    May 1, 2021 · Our review of the history of modern static control begins in the late 1960s. The first materials used for static control then were carbon-filled conductive ...
  8. [8]
    Triboelectric Charging of Particles, an Ongoing Matter
    Oct 17, 2022 · This mini-review is to provide an overview of different tribocharging concepts that have been applied to study and realize the formation of ordered stable ...
  9. [9]
    [PDF] Antistatic Additives - Deuteron GmbH
    Since 1980 Deuteron is well-known for the production of antistatic additives for coatings and plastics. Our antistatic additives based on quaternary ammonium ...
  10. [10]
    Antistatic Agent - an overview | ScienceDirect Topics
    Antistatic agents are chemicals used to treat the material surfaces to eliminate or minimize the build-up of static electricity generated by the triboelectric ...
  11. [11]
    Antistatic Agents - Lankem
    Apr 9, 2021 · Antistatic agent work by increasing the electrical conductivity of the surface, this is achieved by either being conductive or by adsorbing ...Missing: mechanisms credible<|control11|><|separator|>
  12. [12]
    Antistatic Additives & Their Use | AMPACET CORPORATION
    Antistats are external (topical) or internal (migratory or non-migratory). Internal types include anionic, cationic, nonionic, and inert conductive fillers. ...Missing: definition examples advantages disadvantages<|control11|><|separator|>
  13. [13]
    Antistatic Additives for Plastics: Complete Guide to Selection and ...
    Feb 27, 2025 · Internal antistatic additives are blended into plastic resins during manufacturing, offering a long-lasting antistatic effect. These additives ...Missing: definition examples disadvantages
  14. [14]
    Antistatic Additives for Polymers: Types Benefits & How to Choose
    Aug 10, 2025 · Static electricity in polymers isn't just a nuisance – it disrupts production, attracts contaminants, and even sparks safety hazards.
  15. [15]
  16. [16]
  17. [17]
  18. [18]
    [PDF] additives for plastics processing - Kao Chemicals
    The effects of external antistatic agents. Molded plastics. Antistatic agents. Dilution. (times). Application method. Surface resistivity. (Ω). *. Results of.
  19. [19]
    What is the difference between internal and external antistatic agents?
    Aug 12, 2025 · Immediate Results: One of the main advantages of external antistatic agents is their ability to provide instant antistatic protection.
  20. [20]
    Antistats - an overview | ScienceDirect Topics
    External antistats are easily lost from the polymer through handling (e.g., rinsing) and tend to be used more frequently in applications where a short-term ...
  21. [21]
    Antistatic additives for plastic: What are they and their benefit
    External antistatic additives work effectively for just around 6 weeks. After that, the protective layer they created will be gradually abraded by the influence ...
  22. [22]
    (PDF) Antistatic polymeric materials - ResearchGate
    Aug 6, 2025 · This review article presents the benefits and drawbacks of antistatic additives for polymer materials used in industry and in the construction industry.
  23. [23]
    Determining migration of GMS antistat in polypropylene
    Internal GMS antistats migrate to the surface due to limited compatibility. During cooling, the polar head of GMS is drawn to the surface.
  24. [24]
    [PDF] Antistatic textiles: current status and future outlook
    Jun 8, 2024 · Antistatic textiles control ESD, which is caused by static charge accumulation. They are essential in sensitive environments to prevent ...
  25. [25]
    Enhancing Anti-Static Performance of Fibers by Construction ... - NIH
    Jul 9, 2021 · The hybrid antistatic agent SCNTs/OAA composed of sulfonated carbon nanotubes (SCNTs) and organic antistatic agent (OAA) was treated on the fiber surface.
  26. [26]
  27. [27]
    Non-ionic Antistatic Agents Professional Manufacturer | Kefeng
    Antistatic agents are used in fabric treatment to reduce static electricity buildup, ensuring enhanced comfort and safety for wearers. How do antistatic agents ...
  28. [28]
    Anti-Static Agent Manufacturer, Supplier - Major Product
    Anti-static agents enhance hydrophilicity, increase fiber smoothness, and use ionic substances to neutralize electrical resistance and increase conductivity.
  29. [29]
    Anti-static Textile:Conductivity Granting Smart Properties - Tuball
    Aug 9, 2023 · Anti-static textiles possess properties that repel or reduce the accumulation of dust, ensuring cleaner surfaces and minimizing contamination ...
  30. [30]
    Fabrication of Conductive Fabrics Based on SWCNTs, MWCNTs ...
    Dec 8, 2022 · This paper comprehensively describes conductive fabrics based on single-walled carbon nanotubes, multi-walled carbon nanotubes, and graphene.
  31. [31]
  32. [32]
    Diesel Fuel Additives - DieselNet
    Sometimes referred to as antistatic additives are added to diesel fuel ... acids, alkyl orthophosphoric acids, alkyl phosphoric acids and aryl sulfonic acids.
  33. [33]
    [PDF] Aviation Fuels - Chevron
    ASTM D 1655 The Standard Specification for Aviation Turbine Fuels includes specifications for two kerosine-type jet fuels: Jet A and Jet A-1. Jet A is used ...
  34. [34]
    [PDF] AvGuard™ SDA - Aviation Fuel Additive - Afton Chemical
    AvGuard SDA is approved for use in jet fuel specified against: • ASTM D1655. • ASTM D7566. • US MIL-DTL-83133. • DefStan 91-091. • CAN/CGSB-3.23-2019. • CAN/ ...
  35. [35]
    [PDF] Determination of static dissipater additives in aviation turbine fuel ...
    Typically used static dissi- pater additives in aviation turbine fuel are long alkyl chained sulfonic acids, here dinonylnaphthalene sulfonic acid (DINNSA) and ...
  36. [36]
    Anti-static fuel additive and preparation method thereof
    They have good antistatic effect in gasoline, diesel oil. Existing anti static additive is by polysulfones, two kinds of polymers of polyamine and solvent ...
  37. [37]
    Additives to Treat Problems during the Movement and Storage of Fuels
    For these reasons, static dissipaters have been added to jet fuel since the 1950s to augment extensive procedures. Page 8. 7 Additives to Treat Problems during ...
  38. [38]
    An Overview of ANSI/ESD S20.20 | EOS/ESD Association, Inc.
    Feb 6, 2025 · It outlines comprehensive guidelines for identifying and implementing ESD control measures such as flooring, seating, packaging, and personnel grounding.
  39. [39]
  40. [40]
    Bags and Labels - Desco
    $$1 deliveryDesco Statshield® Bags. Statshield® bags create a faraday cage to protect ESD sensitive contents from electrostatic fields and electrostatic discharges (ESD).
  41. [41]
    ElectroStatic Dissipative (ESD) Coatings Explained - Resources
    ESD-coated surfaces prevent sparks, shorts, and sudden discharges that damage electronics or lead to explosions. "ESD coatings are partially conductive, which ...
  42. [42]
    The Role of Inorganic Fillers in Electrostatic Discharge Composites
    We reported a deep analysis of the role of conductive fillers in the formation of filler networks to allow electric charge movements.
  43. [43]
    Conductex Carbon Black Products For Esd Applications
    Oct 30, 2024 · Our Conductex carbon blacks prevent electrical damage and provide the required level of conductivity for your resin system.Missing: metallic fillers
  44. [44]
    Static Control Products – ACL Staticide, Inc.
    ACL Staticide provides static control, dissipative floor paint, ESD polishes and wearables, PCB cleaning chemicals and packaging and static instruments.ACL Worldwide Distributors · Staticide ® ESD Clear Coatings · ESD Wearables
  45. [45]
    Difference Between Conductive, Dissipative, Insulative and Antistatic
    Dissipative materials have a surface resistivity equal to or greater than 1 x 10^5 Ω/sq but less than 1 x 10^12 Ω/sq or a volume resistivity equal to or ...
  46. [46]
    Static Control Flooring – Conductive or Dissipative? - ESD Association
    May 1, 2020 · A dissipative flooring material is one that has a resistance to ground >1.0 x 10 6 ohms and < 1.0 x10 9 ohms.
  47. [47]
    Avoiding yield loss: removing ESD from your cleanroom
    Sep 6, 2023 · Experts estimate that up to one third of printed circuit board (PCB) failures are from electrostatic discharge (ESD).Missing: agents case study
  48. [48]
    Contamination and ESD Control in High Technology Manufacturing
    ... ESD control strategies and techniques, and it is filled with case studies that illustrate key principles and the benefits of contamination and ESD control.<|control11|><|separator|>
  49. [49]
    Quaternary Ammonium Compound Toxicity - StatPearls - NCBI - NIH
    Jul 15, 2023 · [7] QACs are known irritants and corrosive agents at high concentrations; repeated exposures can result in severe burns, persistent dermatitis, ...Continuing Education Activity · Introduction · Evaluation · Treatment / ManagementMissing: antistatic | Show results with:antistatic
  50. [50]
    Do Your Child's Clothing, Bedding and Mattress Have Toxic ...
    May 22, 2025 · It can cause dermatitis and other severe skin reactions. Nonylphenol ethoxylates (NPEs) are used as cleaning agents during textile processing.
  51. [51]
    Quaternary Ammonium Compounds and Contact Dermatitis - NIH
    Jun 30, 2023 · Quaternary ammonium compounds may cause irritancy and contact dermatitis, and should be used cautiously in patients with compromised skin barriers.
  52. [52]
    First Aid for Chemical Exposures - CCOHS
    Remove all contaminated clothing from the victim, making sure you do not contaminate yourself in the process. Monitor for hypothermia when cooling large burns.
  53. [53]
  54. [54]
    First Aid Procedures for Chemical Hazards | NIOSH - CDC
    If this chemical contacts the skin, immediately flush the contaminated skin with soap and water. If this chemical penetrates the clothing, immediately remove ...
  55. [55]
    [PDF] Nonylphenol and its Ethoxylates - CCME
    NP and NPEs with 1–3 ethoxylate groups show mild bioaccumulation in aquatic organisms, with the majority of calculated bioaccumulation factors. (BAFs) and ...
  56. [56]
    First Aid in Case of Pesticide Exposure | US EPA
    Dec 31, 2024 · Call 911 if the person is unconscious, having trouble breathing or having convulsions. Check the label for directions on first aid for that ...
  57. [57]
    Quaternary Ammonium Compounds ADBAC and DDAC Fact Sheet
    Feb 14, 2023 · If any exposures occur, be sure to follow the First Aid instructions on the product label carefully. For additional treatment advice, contact ...
  58. [58]
    Toxicology of perfluorinated compounds
    Dec 6, 2011 · These compounds can bioaccumulate and also undergo biomagnification ... fluorinated compounds from traditional foods among Inuit in Nunavut, ...
  59. [59]
    Fluorinated Chemicals and the Impacts of Anthropogenic Use
    Aug 10, 2025 · The bioaccumulation potential, capacity for long-range transport, toxicity and persistence of organofluorines challenge human society to ...
  60. [60]
    2.6 PFAS Releases to the Environment
    This section summarizes sources of PFAS releases to the environment that have the potential for significant environmental impact.
  61. [61]
    Textile effluent treatment methods and eco-friendly resolution of ...
    This review focuses on textile effluent treatment techniques and the physical-chemical treatment parameters taken into consideration during primary, secondary, ...Missing: waterways | Show results with:waterways
  62. [62]
    [PDF] Biodegradability Fatty acids, C8-18 and C18-unsatd., mixed esters ...
    The substance is readily biodegradable according to OECD criteria, based on read-across studies of structurally related substances.
  63. [63]
    OECD 301B: CO2 Evolution Ready Biodegradability Test - Aropha
    The OECD 301B test measures CO2 evolution to determine ready biodegradability in an aqueous environment, measuring CO2 formation over 28 days.
  64. [64]
    Quaternary Ammonium Compounds: A Chemical Class of Emerging ...
    Quaternary ammonium compounds (QACs), a large class of chemicals that includes high production volume substances, have been used for decades as ...
  65. [65]
    Registration guidelines for fuels and fuel additives | US EPA
    The following guidelines apply to Fuel and Fuel Additive Registrations (FFARs) under Title 40 CFR Part 79 as authorized by the Clean Air Act.Missing: antistatic agents
  66. [66]
    Permanent Antistatic Agent Market Size, Growth and Analysis Report
    May 1, 2025 · ... antistatic agents that are derived from renewable resources and have a lower environmental impact. Bio-based antistatic agents, such as ...Market Restraint · Market Opportunity · Regional Analysis
  67. [67]
    Bio-Based Antistatic Agent Market: Key Insights, Drivers, Trends ...
    Aug 15, 2025 · The Bio-Based Antistatic Agent Market is gaining substantial momentum worldwide as industries shift towards sustainable and environmentally ...