Olfactometer

An olfactometer is a designed to deliver stimuli in a precise and controlled manner, enabling the of olfactory , detection, , and while minimizing variables such as airflow, concentration, duration, and contamination. It typically consists of components like carrier air systems, odorant delivery mechanisms (e.g., canisters or liquid bubblers), mass flow controllers for dilution, and computer interfaces for synchronization with physiological recordings or behavioral tasks. The development of olfactometers traces back to the late , with physiologist Hendrik Zwaardemaker credited as the inventor in 1888–1889, when he introduced the first device for clinical quantification of smell acuity through diluted odor presentation. Early olfactometry built on physiological studies from the 1840s by figures like , evolving into standardized tools by the early for assessing odor intensity and quality. Key advancements include the 1916 odor classification system by Hans Henning and post-World War II refinements for environmental and medical applications, culminating in modern digital systems like the Sniffin' Sticks (1996) for comprehensive olfactory testing. Olfactometers are categorized into types such as air-dilution models, which mix odorized air with clean diluents for variable concentrations, and simpler squeeze-bottle designs for basic threshold tests, alongside advanced solenoid-valve systems for integration. Their primary applications span research, including functional MRI studies of processing and behavioral assays in for tasks (e.g., detecting differences in carbon chain lengths with over 90% accuracy), as well as clinical diagnostics for disorders like , Alzheimer's, and post-traumatic . In , they support concentration measurements for pollution monitoring, adhering to standards like those from the .

Introduction

Definition and Purpose

An is a designed to detect and measure odor dilution, , , and concentration by delivering controlled stimuli to subjects or sensors. It enables precise presentation of odorants—volatile chemical compounds that stimulate the —while regulating variables such as airflow and dilution ratios to ensure reproducible results. This device plays a central role in olfactometry, the quantitative study of olfaction, which is the biological responsible for detecting airborne chemical molecules. The primary purpose of an olfactometer is to quantify olfactory thresholds—the minimum concentration at which an is detectable—and to investigate in s and other . It standardizes assessments in , , and environments, facilitating comparisons across studies and applications. By bridging sensory with applied sciences, such as and industrial control, olfactometers help evaluate how odors influence , , and ecological interactions. Olfactometers distinguish between human-based evaluations, which rely on trained panels of assessors to subjective responses to , and instrumental variants that automate delivery for non-human subjects, such as in behavioral studies. In panels, the device presents diluted samples to multiple noses acting as sensors, providing a metric of perceived strength in odor units per cubic meter. Instrumental olfactometers, conversely, support automated systems for precise in entomological research, where they measure attraction or repulsion to specific odorants without intervention.

Historical Development

The olfactometer was invented in by physiologist Hendrik Zwaardemaker, who designed a simple tube-based device that allowed odorants to be drawn into the nostril through controlled inhalation, enabling the measurement of odor detection thresholds. Zwaardemaker refined his olfactometer through subsequent designs between and 1895, incorporating graduated scales for precise dilution and quantification of odor intensity, which laid the groundwork for systematic olfactory psychophysics. In the early , olfactometry advanced through pioneering experiments that expanded on Zwaardemaker's work, including efforts to classify into systematic categories based on perceptual qualities and chemical properties. Researchers at the developed initial methods for determination and odor profiling, such as static dilution techniques, which facilitated broader olfactory experimentation in physiological and psychological studies. In the late , starting in the , olfactometry shifted from static methods—where odors were presented in enclosed vessels—to dynamic approaches that continuously diluted and delivered odorants via , improving reproducibility and control. This evolution included the introduction of panel-based assessments, where multiple human assessors evaluated odors collectively to reduce individual variability, and culminated in the with ASTM standards like E679, which formalized dynamic olfactometry protocols for and measurement. In the late 20th and early 21st centuries, the adoption of the EN 13725 (revised 2022) standardized dynamic olfactometry across , specifying procedures for odor concentration determination using human panels and defining units like odor units per cubic meter. Portable field olfactometers emerged in the , such as the Nasal Ranger device, enabling on-site odor assessments without laboratory constraints. By the , integration with advanced further, with MRI-compatible olfactometers allowing odor delivery during functional brain imaging to study olfactory processing. Overall, progression to electronic and automated systems by the enhanced precision, incorporating digital controls for dilution and real-time data logging.

Operating Principles

General Mechanisms

Olfactometers operate by delivering controlled concentrations of odorants to subjects through precisely regulated air streams, typically mixing odorized air with clean, odor-free air to achieve desired dilution levels. This process often employs , inert tubing, or dilution chambers to blend the components without , ensuring reproducible exposure conditions. The system generates a consistent that carries the diluted odorant to the subject's nasal passages, allowing for controlled presentation of stimuli with rapid onset and offset to minimize sensory . Key components of an olfactometer include the odor source, such as a sample canister or vapor ; an air system providing continuous, humidified clean air at rates around 8 L/min to maintain physiological sniffing conditions; dilution mechanisms like mass controllers or valves for accurate mixing; and delivery nozzles or nasal masks that direct the stimulus precisely. Materials such as Teflon or are used throughout to prevent adsorption of ants, ensuring reliability. These elements work together to produce stable, quantifiable presentations without introducing variables like fluctuations or changes that could affect perception. Sensory detection in olfactometry relies on human olfactory thresholds, defined as the lowest concentration at which an is detectable by 50% of a trained panel. This involves concepts such as , which quantify odor strength in dimensionless terms based on perceived , and dilution-to-threshold (DT) ratios, representing the factor by which an odor must be diluted to reach the detection . Panelists assess samples in a controlled manner, often using forced-choice methods to identify the odorous sample among blanks, with thresholds calculated as the of individual responses. The physical principles governing olfactometer function center on gas diffusion, vapor pressure of odorants, and airflow dynamics to achieve uniform exposure. Odorants volatilize into the air stream based on their vapor pressure, diffusing evenly when mixed with carrier gas to prevent localized concentrations. Airflow is managed to avoid saturation effects, where high concentrations overwhelm receptors, or adaptation, where prolonged exposure diminishes sensitivity; typical flows ensure laminar conditions for consistent delivery. A basic dilution equation is given by: \text{Dilution factor} = \frac{\text{total air flow}}{\text{odorant flow}} where flows are measured in liters per minute (L/min), yielding the ratio that determines concentration.

Measurement Standards and Thresholds

Olfactory represent fundamental metrics in olfactometry, distinguishing between detection and levels. The detection threshold is defined as the lowest concentration of an odorant at which it is noticed by 50% of assessors, serving as an for the minimum perceptible stimulus. In contrast, the recognition threshold occurs at the concentration where the odor's quality or identity can be reliably discerned by 50% of assessors. thresholds encompass both detection and recognition as the limits of olfactory , while thresholds measure the smallest incremental change in odor concentration that can be discriminated, often relevant for comparative assessments. Panel-based evaluation forms the core of standardized olfactometric testing, relying on trained assessors to minimize subjective . Protocols typically require 4 to 8 trained panelists per , selected for their consistent performance against reference odors like n-butanol to ensure reliability. A forced-choice method is employed, where assessors evaluate 3 or 4 samples simultaneously—typically one odorous and the rest blanks—and must identify the odorous sample, reducing guessing and expectation errors compared to yes/no formats. This ascending concentration series presentation starts at low dilutions and progresses until the detection threshold is reached, with responses statistically analyzed for 50% correct identification. Key international standards govern these measurements to ensure comparability. The EN 13725 (originally published in 2003 and revised in 2022) outlines dynamic olfactometry procedures, defining concentration in European odor units per cubic meter (/m³) as the dilution factor required to reach the detection of 1 /m³. In the United States, ASTM E679 specifies a forced-choice ascending concentration series for determining and taste , emphasizing statistical limits for panel responses. For gas odorants, ASTM D6273 provides methods to assess intensity, including detection and readily detectable levels using olfactory evaluation. These standards prioritize controlled conditions, such as clean air dilution and panel screening, to quantify potency. Beyond concentration, hedonic tone and intensity scales evaluate subjective odor qualities. Hedonic tone assesses pleasantness on scales ranging from -4 (extremely unpleasant) to +4 (extremely pleasant), capturing emotional responses independent of . is often rated on a 0-6 category scale, where 0 indicates no odor and 6 denotes overwhelming strength, allowing correlation with concentration for annoyance prediction. Odor concentration is calculated as $2^{n-1} ou/m³, where n is the dilution step at which 50% detection occurs in binary dilution series, reflecting the geometric progression of thresholds in dynamic olfactometry. Several error sources can influence measurement accuracy, necessitating rigorous controls. Inter-individual variability arises from physiological differences in olfactory , with thresholds varying by factors like age, health, and among panelists. Olfactory occurs when prolonged exposure desensitizes receptors, inflating thresholds and requiring short presentation intervals. Environmental factors, such as and , also affect thresholds—higher can elevate detection levels by altering mucosal conditions—thus standards mandate controlled ranges (e.g., 50% relative humidity and 23°C) to mitigate these influences.

Types of Olfactometers

Flow Olfactometers

Flow olfactometers are laboratory instruments designed to deliver odor stimuli through a continuous stream of air, enabling precise temporal control in olfactory experiments. These devices maintain a steady airflow that passes over an odor source before being transported via tubing to the subject, often incorporating solenoid valves or vacuum systems to switch rapidly between odorized and clean air streams. This setup ensures minimal mechanical or thermal artifacts during stimulus presentation. In operation, flow olfactometers provide a constant background of filtered, heated, and air, typically at 35–37°C and relative above 50%, to mimic physiological conditions and prevent nasal drying. pulses are introduced with rapid onset and offset times, often achieving times around 160 ms, allowing for square-wave stimulus profiles suitable for electrophysiological recordings. They are frequently employed in dual-choice configurations, such as Y-tube olfactometers for , where equal airflow rates—adjusted based on size, often in the range of 1–5 L/min total—direct stimuli into separate arms for behavioral choice assays. Key advantages of flow olfactometers include their ability to minimize olfactory adaptation through quick stimulus switching and stable concentration delivery, with only minor drops (e.g., 5.9%) over extended use, making them ideal for behavioral and studies. These devices excel in timing-critical applications, such as event-related potential measurements in humans or assays in insects. However, limitations include their primary suitability for controlled laboratory settings, where quantitative dilution for environmental odor standards receives less emphasis, and potential issues like backflow contamination if valves are not calibrated properly. Higher flow rates beyond 5 L/min can cause nasal irritation in subjects. Modern flow olfactometers draw inspiration from early designs like Hendrik Zwaardemaker's 1888 two-tube system, which used airflow to transport without direct contact, evolving into computer-controlled versions for applications such as precise odor pulse timing in olfactory studies. In research, Y-tube variants have been widely used to assess preferences, for example, in evaluating responses to volatiles.

Dynamic Dilution Olfactometers

Dynamic dilution olfactometers are laboratory instruments designed as multi-port systems that split streams of clean, odor-free air into controlled flows, dynamically mixing these with an odorous sample to generate precise stepwise dilutions, often in ratios such as :2 increments up to approximately 15,000:1. These devices employ low-adsorbency materials like , Teflon, and glass to prevent sample contamination or alteration, with neutral air flushing between presentations to maintain integrity. Automated mass flow controllers regulate the mixing ratios, enabling simultaneous delivery to multiple panelists through sniff ports, typically four to six, in compliance with standards like EN 13725. In operation, these olfactometers present diluted samples to a trained panel using forced-choice methods, such as three-alternative forced choice, where panelists identify the odorous port among blanks. The detection threshold (DT) is determined as the dilution ratio at which 50% of panel responses indicate detection, calculated via the of the last negative and first positive responses. Results are quantified in odor units per cubic meter (/m³), calibrated against n-butanol as a reference, providing a measure of concentration for regulatory purposes under EN 13725. The key process begins with sample collection in inert Tedlar or Nalophan bags using a depression pump, ensuring analysis within 30 hours to preserve integrity as per EN 13725 protocols. Automated dilution steps then create a series from high ratios (e.g., 15,000:1) down to 1:1, with assessments extending to on scales like 0-5, hedonic tone (pleasantness), and character description for comprehensive profiling. Each sample evaluation typically requires 20-30 minutes per panelist, involving ascending presentations to minimize adaptation. These olfactometers offer advantages in reproducibility, making them essential for in , as standardized procedures yield consistent results across labs. They effectively handle complex mixtures by mimicking human , supporting applications in quantification without needing . Limitations include the necessity for a controlled environment free of external odors, which restricts on-site use and increases setup costs. Panel sessions are time-intensive, often limited to three hours total with costs around $350 per sample, and results can vary due to inter-individual sensitivity differences despite training.

Field Olfactometers

Field olfactometers are portable, handheld devices engineered for direct on-site evaluation of ambient odors, enabling assessments without the need for sample collection and laboratory transport. These instruments typically feature adjustable dilution valves and internal mixing chambers that blend odorous ambient air with odor-free air purified through filters. A representative example is the Nasal Ranger, a lightweight tool approximately 14 inches long, designed to generate precise dilution ratios by drawing in ambient air via a sample and combining it with filtered clean air from replaceable cartridges. In operation, a single trained assessor positions the device upwind at the odor source, such as plumes or sites, and sequentially sniffs diluted samples to identify the lowest concentration where the becomes imperceptible. Dilution ratios such as 2:1, 4:1, 7:1, 15:1, 30:1, and 60:1, with higher ranges available in some models, with the assessor recording the dilution-to-threshold (D/T) value at detection, often using a concealed dial to minimize ; this process relies on the individual's olfactory rather than a panel of evaluators. These devices offer key advantages, including real-time quantification of strength to validate complaints and portable deployment for dynamic sources like or industrial emissions, where they express results in field odor units (ou_f) equivalent to D/T ratios. However, limitations include high subjectivity tied to the operator's personal factors such as or , reduced precision compared to controlled olfactometry, and susceptibility to environmental interferences like , direction, or airborne contaminants that can alter air mixing. Field olfactometers like the Nasal Ranger align with U.S. EPA-recommended approaches for investigations, supporting regulatory compliance in ambient air quality assessments, while service providers such as Olfatec utilize similar portable models for on-site unit evaluations.

Applications

Environmental and

Olfactometers play a crucial role in by quantifying emissions from sources such as landfills, plants, and agricultural operations, enabling the assessment of potential impacts on surrounding communities. Dynamic olfactometry, standardized under EN 13725, measures concentrations in units (ouE/m³) and facilitates the calculation of emission rates, often expressed as ouE/m²/s for area sources like composting pads or ouE/s for point sources like stacks. These measurements support compliance with regulations, including the Union's Emissions Directive (2010/75/), which requires best available techniques for preventing and controlling from installations. In settings, olfactometers are employed to monitor effluents from sectors like and chemical manufacturing, where volatile organic compounds contribute to nuisance. For instance, in plants, dynamic olfactometry identifies emission hotspots, aiding in the design and evaluation of abatement systems such as biofilters or . Site diagnostics using olfactometry integrate with to predict plume behavior and off-site concentrations, helping operators optimize control measures and ensure regulatory adherence. Sampling protocols involve collecting air from emission stacks for point sources or at site boundaries for diffuse emissions, followed by laboratory analysis via dynamic olfactometry. Combining field olfactometry for rapid on-site assessments with laboratory methods enhances nuisance evaluations, particularly for intermittent odors, by correlating perceived intensity with quantitative data. A notable case study from the Edmonton Waste Management Centre's co-composting facility demonstrates olfactometer-guided controls: field olfactometry identified high odor strengths from biosolids lagoons and composting areas, leading to targeted abatement like improved aeration and covering, which reduced detectable odors and community complaints over monitoring periods from 1997 to 2003. Historical developments post-1990s, including the adoption of EN 13725 in 2003, shifted practices toward standardized, reproducible measurements, replacing earlier subjective methods and enabling better integration into emission inventories. Challenges in these applications include the variability of odor plumes due to meteorological factors, which complicates accurate sampling and modeling, as well as establishing enforceable legal thresholds—such as ambient limits of 1–3 ouE/m³ commonly referenced in and guidelines to minimize .

Gas Safety and Odorant Verification

Olfactometers play a critical role in gas safety by verifying the effectiveness of odorants added to , ensuring that leaks can be detected before reaching hazardous concentrations. is inherently odorless, so utilities inject sulfur-based odorants such as tertiary butyl mercaptan (TBM) or (THT) to impart a distinctive rotten-egg smell. The primary purpose of this verification is to confirm that the odorized gas remains detectable at one-fifth of the lower explosive limit (LEL), equivalent to approximately 1% gas in air (20% LEL), thereby preventing undetected leaks in pipelines, distribution systems, or residential settings that could lead to explosions or asphyxiation. The standard method for odorant verification follows ASTM D6273, which employs dynamic or flow olfactometers to assess odor intensity through controlled dilution of gas samples with clean air. In this process, gas is sampled from points where odorant mixing is complete, such as near the end of distribution lines, and blended with air to simulate low-concentration scenarios, targeting detectability around 5 ppmv for common odorants like THT. Trained panels of operators—typically non-smokers screened for olfactory sensitivity—conduct forced-choice sniff tests, presenting diluted mixtures in odor-free ports to determine the threshold detection level (faint odor) and readily detectable level (easily identifiable odor). These tests use triangle or yes/no protocols to minimize bias, with results quantifying odor strength to ensure compliance; for instance, the gas must produce an odor intensity rating of at least "easily detectable" (level 2 on a 0-5 scale) at the 1/5 LEL threshold. Utilities perform routine checks, often monthly, using portable olfactometers like the Bacharach Odorometer or DTEX systems, to maintain uniform odorant distribution and prevent fade due to adsorption in pipelines. This practice evolved from early 20th-century safety concerns, particularly following the 1937 in , which killed nearly 300 people due to unodorized gas accumulation and prompted state-level mandates. Federal regulations solidified in 1970 when the U.S. issued the first pipeline safety rules under 49 CFR Part 192, requiring odorization for all combustible gases in populated areas to reduce accident risks. The advantages of olfactometer-based verification include quantitative assurance of odorant efficacy—far superior to subjective sniff tests—ensuring consistent addition rates (e.g., 0.2-4 lb/MMSCF) and early , which has significantly lowered explosion incidents since implementation. Dynamic dilution techniques, as outlined in specialized olfactometer types, enable precise control over presentation concentrations during these safety assessments.

Medical and Olfactory Research

Olfactometers play a crucial role in clinical diagnostics by providing objective assessments of olfactory function, particularly for detecting and in ear, nose, and throat () clinics. These devices deliver controlled concentrations of odorants to measure detection thresholds and discrimination abilities, enabling precise evaluation of olfactory impairment. In conditions like post-COVID-19 olfactory dysfunction, olfactometers support the of loss, which affects up to 80% of severe cases and serves as an early indicator of neurological involvement. For neurodegenerative disorders such as , olfactory testing with olfactometers complements standardized batteries like the Smell Identification Test (UPSIT) to identify as a prodromal marker, with impaired olfaction predicting faster cognitive decline in older adults. Olfactory training devices, often incorporating olfactometer-like precise odor delivery, have demonstrated efficacy in rehabilitating following infection, with double-blind studies showing significant recovery after three months of twice-daily training. In olfactory research, olfactometers facilitate psychophysical experiments focused on discrimination tasks, where participants identify or differentiate scents under varying concentrations, and sensitivity detection to quantify perceptual thresholds. These setups allow researchers to explore olfaction's neural basis, including rapid measured within 50-200 milliseconds of onset, which aligns with physiological responses in the . Animal studies leverage flow olfactometers in behavioral paradigms, such as the Y-maze apparatus for like mosquitoes, to investigate olfactory-guided and learning; for instance, exhibits conditioned responses to host odors in Y-maze olfactometers, revealing memory retention up to 24 hours post-. In , systems like the RWD Olfactometer enable cognitive assessments by associating stimuli with rewards, supporting studies on olfactory and in behavioral . Advanced olfactometer designs enhance applications, including MRI-compatible models that deliver odors via without magnetic interference, allowing synchronized fMRI imaging of odor-evoked brain activity. Multimodal variants with real-time computer control support up to eight odor channels for precise stimulus sequencing during . Since the early , open-source low-cost olfactometers have proliferated in laboratories, offering affordable options for multi-odor delivery and integration with behavioral assays. Key findings from such research highlight olfactometers' utility in aging studies, where they document a progressive decline in olfactory sensitivity after age 60, affecting over 50% of individuals aged 65-80 and correlating with broader sensory and cognitive impairments. Behavioral experiments using olfactometers also reveal effects, with temporary threshold shifts following prolonged exposure, underscoring the dynamic nature of olfactory . Portable self-administered olfactometers, such as multi-channel devices for home use, enable rapid threshold testing outside clinical settings, improving accessibility for ongoing monitoring of olfactory function.

References

  1. [1]
    Olfactometer - an overview | ScienceDirect Topics
    An olfactometer is defined as a device used to present odor stimuli in a standardized manner, allowing control over variables such as air flow, odor ...Introduction to Olfactometers in... · Applications in... · Clinical and Translational...
  2. [2]
    A brief history of olfaction and olfactometry
    Jan 18, 2008 · In 1927, Crocker and Henderson devised a system involving four basic odours: fragrant, acid, burnt and caprylic (i.e. smelling like a goat).Odour Classification · Olfactory Testing In The... · Olfaction And Olfactometry...
  3. [3]
    Olfactometer - an overview | ScienceDirect Topics
    An olfactometer is an instrument used for odor or flavor evaluation by estimating volatile substances in terms of quality and intensity.
  4. [4]
    OLFACTOMETER Definition & Meaning - Merriam-Webster
    The meaning of OLFACTOMETER is an instrument for measuring the sensitivity of the sense of smell especially in regard to intensity, concentration, ...
  5. [5]
    Physiology, Olfactory - StatPearls - NCBI Bookshelf
    Olfaction is the chemical sensation of gaseous odorants colloquially referred to as the ability to smell.Missing: olfactometer | Show results with:olfactometer
  6. [6]
    Olfactometer - WUR
    An olfactometer is a machine designed to deliver odours in a precisely-controlled manner, for instance in order to objectively assess olfactory function (' ...Missing: definition | Show results with:definition
  7. [7]
    Olfactometry | Silsoe Odours | 01525 860222
    Mar 7, 2023 · Olfactometry is the process of measuring the concentration and intensity of odour, often used for environmental monitoring.Missing: definition | Show results with:definition
  8. [8]
    [PDF] United States Environmental Protection Agency
    A brief review of the sensory properties of odor and some of the attributes of human olfactory response is presented to facilitate understanding of odor ...
  9. [9]
    Odour Detection Methods: Olfactometry and Chemical Sensors - PMC
    Although dynamic olfactometry represents the standardized objective method for the determination of odour concentration, it is affected by some limitations.
  10. [10]
    What is olfactometry and for what purposes is it used? - EnvironOdour
    Olfactometry employs a panel of human noses as sensors. A human nose can detect odour at concentrations well below the sensitivity levels of chemical ...
  11. [11]
    Scents and sensibility: Best practice in insect olfactometer bioassays
    Jul 27, 2023 · INTRODUCTION. The olfactometer is an invaluable tool used by chemical ecologists to study insect behaviour in response to chemical stimuli.
  12. [12]
    The invention of the olfactometer by Hendrik Zwaardemaker in 1888 ...
    The olfactometer was invented by the Dutch physiologist Hendrik Zwaardemaker (1857-1930), whose work we here describe in detail, in 1888. From that date ...
  13. [13]
    (PDF) A brief history of olfaction and olfactometry - ResearchGate
    Aug 6, 2025 · This paper explores the progression of knowledge over the years to the present day. Particular emphasis is placed on odour classification and olfactometry.Abstract · References (38) · Recommended Publications
  14. [14]
    [PDF] A Review of The Science and Technology of Odor Measurement
    Dec 30, 2005 · Laboratory olfactometry involves diluting the odorous air sample at varying concentrations then presenting the diluted odor to human assessors.
  15. [15]
  16. [16]
    An expandable, fully automated, mobile, MRI-compatible olfactometer
    Mar 1, 2016 · Presentation of an olfactometer design to overcome the challenges in fMRI experiments. · Challenges due to the magnetic environment, space and ...
  17. [17]
    Olfactometer - an overview | ScienceDirect Topics
    An olfactometer is defined as a device used to deliver odors reliably for sensory testing ... Signal detection theory provides a model of subject behavior that ...
  18. [18]
    [PDF] State of the art olfactometers. Different types - Uniscience Publishers
    May 20, 2021 · An olfactometer is a device designed to detect and measure odor dilution. It is also used to quantify and qualify human ol- faction, as well ...
  19. [19]
    None
    ### Summary of Mathematical Concepts for Olfactometers
  20. [20]
    Odor Detection Threshold - an overview | ScienceDirect Topics
    A recognition threshold is the lowest concentration where odor quality is reliably discerned. A differential threshold is the smallest amount by which a ...
  21. [21]
    EN13725 - Scentroid
    European Dynamic olfactometry is described in detail by the standard EN 13725. This standard was last released in 2003 and is currently under review for ...
  22. [22]
    E679 Standard Practice for Determination of Odor and Taste ... - ASTM
    Sep 12, 2019 · 5.1 Sensory thresholds are used to determine the potential of substances at low concentrations to impart odor, taste, skinfeel, etc. to some ...
  23. [23]
  24. [24]
    D6273 Standard Test Method for Natural Gas Odor Intensity - ASTM
    Mar 14, 2024 · This test method covers the procedures for determining the threshold detection level, readily detectable level, and odor intensity of natural gas.
  25. [25]
    The 9-point hedonic scale for odors. - ResearchGate
    The determination of the hedonic tone refers to a 9 point scale with values ranging from "−4-extremely unpleasant" to "+4-extremely pleasant".
  26. [26]
    Improvement of Odor Intensity Measurement Using Dynamic ...
    The guide- line uses a category scaling (0–6) in classifying the odor intensity without any reference. This is more variable and less consistent than master ...
  27. [27]
    Effects of Cognitive Factors on Perceived Odor Intensity in ...
    Nov 16, 2007 · This superficial inconsistency in perceived intensity, as seen in Experiment 1, may also be due to individual variability in odor adaptation/ ...Missing: sources | Show results with:sources
  28. [28]
    The Influence of Humidity on Assessing Irritation Threshold of ...
    Humidity affects olfactory function and thus influences odor thresholds; however, a similar effect has not been shown for sensory irritation thresholds. The ...
  29. [29]
    Methods for building an inexpensive computer-controlled ...
    Both designs offer unique advantages and problems. Continuous flow olfactometers enable very fast onset and offset timing, thereby creating a nice, square- ...
  30. [30]
    Advantages and Limitations of Measurement Methods for Assessing ...
    The aim of this work is to carry out a comparative analysis of the methods available on the market for measuring the content of odorous substances in the air.
  31. [31]
    Nasal Ranger - Field Olfactometer - St. Croix Sensory, Inc.
    Nasal Ranger is the state-of-the-art in field olfactometry for confidently measuring and quantifying odour strength in the ambient air.
  32. [32]
    None
    ### Summary of Nasal Ranger Field Olfactometer from Brandt et al. (2011)
  33. [33]
    odor units testing lab and dispersion modelling services - Olfatec
    We provide services of odor unit assessment in point sources and open fields. Olfatec provides onsite odor control services and consulting.Missing: ou_f | Show results with:ou_f<|control11|><|separator|>
  34. [34]
    Review State-of-art of the legislation on odour emissions with a ...
    May 1, 2024 · This review would like to point out the state-of-art of the European legislation for the odour pollution determination and management.
  35. [35]
    Summary and Overview of the Odour Regulations Worldwide - MDPI
    The guideline also fixed odour concentration limits in terms of 2 000 ouE∙m−3 for point sources and 300 ouE∙m−3 for diffuse sources. This regional regulation ...Missing: m³ | Show results with:m³
  36. [36]
    Understanding Odor Nuisance and Control in the Food Industry
    When utilizing an olfactometer to measure odor, a cohort of individuals is exposed to the odor sample through the air dilution unit of the olfactometer.
  37. [37]
    Odour impact assessment by means of dynamic olfactometry ...
    The results of the odour dispersion modelling confirmed the outcomes of the olfactometric survey and they were further validated through a “questioning” survey, ...
  38. [38]
    The Art And Science Of Odor Modeling | BioCycle
    Aug 1, 2013 · ... odor modeling study at a composting facility in Lisbon, Portugal (Riberio, 2010). Odor emission rates varied from 430 to 3,200 OU/m3 at the ...
  39. [39]
    [PDF] Odour Impact Assessment Guidance for EPA Licensed Sites (AG5)
    Representative sampling for olfactometry analysis of air may be suitable for point source emissions or at times ambient assessments on a site (i.e. within a ...
  40. [40]
    The Use of Field Olfactometry in the Odor Assessment of a Selected ...
    The odor concentrations for point number 10 range from 6.32 ou/m3 to 43.49 ou/m3. The highest concentration was recorded in July 2022 (43.49 ou/m3), and the ...2. Materials And Methods · 2.2. Odor Concentration... · 3. Results And Discussion
  41. [41]
    None
    ### Case Study Summary: Odor Assessment in a Co-Composting Facility Using Olfactometry
  42. [42]
    Odour impact assessment by considering short-term ambient ...
    Legend denotes the dispersion models according to each concentration threshold (1 ouE/m3 in green, 3 ouE/m3 in yellow and 5 ouE/m3 in red) of the selected odour ...Missing: m³ | Show results with:m³
  43. [43]
    An overview of odour regulation throughout North America - Olores.org
    Nov 3, 2014 · Ontario's guideline approach has been to limit odors to 1-O.U. at a receptor, which is essentially no perceptible odour. Permits in other ...Missing: m³ | Show results with:m³
  44. [44]
  45. [45]
    [PDF] Principles of Odorization - ASGMT
    This intent of this paper is to provide basic information regarding the process of odorizing natural gas, which includes characteristics of chemical odorants, ...
  46. [46]
    [PDF] Technology Brief Odor Detection Threshold Study - NYSEARCH
    These detection levels are important because industry safety standards require that natural gas contains a sufficient level of odorant so that it is readily.
  47. [47]
    [PDF] Natural Gas Odor Intensity1
    This standard is issued under the fixed designation D 6273; the number immediately following the designation indicates the year of.
  48. [48]
    [PDF] Odorometer Manual
    The ODOROMETER may also be used to perform natural gas odor intensity tests in accordance with ASTM D. 6273-98. (ASTM is the American Society for Testing and ...Missing: D6273 | Show results with:D6273
  49. [49]
    Evolution of Gas Safety Through Odorization: The Nose Knows
    Sep 30, 2024 · In 1970, the Department of Transportation (DOT) issued the first federal regulations on gas pipeline safety, including specific requirements ...
  50. [50]
    Olfactory Evaluation in Clinical Medical Practice - MDPI
    Nov 8, 2022 · Current discussion regarding anosmia caused by COVID-19 seems to suggest the loss of smell is caused by viral damage to the olfactory nerve ...
  51. [51]
    Olfactory Dysfunction is Associated with More Severe Clinical ...
    Mar 12, 2021 · Olfactory Dysfunction was present in 80% of patients with severe course. The risk of disease severity is significantly increased with olfactory dysfunction in ...
  52. [52]
    Optimizing olfactory testing for the diagnosis of Parkinson's disease
    Jan 15, 2018 · The 40-item University of Pennsylvania Smell Identification Test (UPSIT) is an effective instrument to detect olfactory dusfunction in Parkinson's disease (PD).
  53. [53]
    Impaired olfaction is associated with cognitive decline and ...
    Impaired olfaction predicts faster cognitive decline and might indicate neurodegeneration in the brain among dementia-free older adults.<|separator|>
  54. [54]
    Olfactory Training Impacts Olfactory Dysfunction Induced by COVID-19
    Dec 16, 2022 · This double-blind randomized pilot study compared the effectiveness of OT versus placebo in the treatment of post-COVID-19 olfactory dysfunction.
  55. [55]
    Clinical Implications of Psychophysical Olfactory Testing
    Mar 18, 2021 · Psychophysical olfactory testing has been widely used to evaluate the ability to smell due to its validated utility and feasibility in clinic.
  56. [56]
    Novel Psychophysical Method for Estimating the Time Course of ...
    The results suggest that olfactory rapid adaptation is measurable psychophysically within 50–200 ms after odor onset, values consistent with physiological ...
  57. [57]
    Olfactory learning and memory in the disease vector mosquito ...
    Jul 1, 2014 · Twenty-four hours after training, the mosquitoes were tested in a Y-maze olfactometer in which they were given the choice between two stimuli ( ...
  58. [58]
    An Integrated Olfactometer System - RWD Life Science
    RWD Olfactometer system is for mouse cognitive assessment, integrated odor delivery, behavioral experiments and software control.
  59. [59]
    A low-cost, MR-compatible olfactometer - PMC - PubMed Central
    This low-cost olfactometer is MR-compatible, delivers odors via nasal cannula, is designed for simple construction, and is suitable for fMRI experiments.
  60. [60]
    A multimodal MR-compatible olfactometer with real-time controlling ...
    Olfactometers are used to deliver odours to the subjects in an objective manner. We present a portable, computer-controlled eight channels olfactometer able to ...
  61. [61]
    Low-cost, open-source device for applying controlled olfactory ... - NIH
    Here, we have developed and tested a simple, low-cost, open-source, stand-alone device to apply selectable controlled sequences of olfactory stimuli in subjects ...Missing: 2020s | Show results with:2020s
  62. [62]
    The influences of age on olfaction: a review - Frontiers
    Decreased olfactory function is very common in the older population, being present in over half of those between the ages of 65 and 80 years.
  63. [63]
    Olfactory adaptation, threshold shift and recovery at low levels of ...
    Chamber inhalation studies have shown dose-dependent olfactory adaptation and temporary olfactory threshold perception shift for particular inhaled substances.Missing: olfactometer behavioral experiments