Prism cover test

The prism cover test (PCT), also referred to as the alternate prism cover test (APCT), is an objective clinical procedure in designed to quantify the degree and direction of , or ocular misalignment, by measuring the prism diopter strength needed to optically neutralize the deviation during alternate eye . This test serves as the gold standard for assessing strabismus magnitude, providing precise measurements in prism diopters that guide diagnosis and management of conditions affecting . The test is performed at both (typically 6 meters) and near (typically 33 centimeters) fixations to measure total deviation, including phoria and tropia. The prism value at neutralization indicates the misalignment angle, with positive values typically denoting esodeviations (inward) and negative values exodeviations (outward) for horizontal misalignments; vertical deviations use signs to specify hyper- (upward) or hypo- (downward) deviations. As a cornerstone of evaluation, the PCT enables clinicians to detect subtle misalignments that may impair or lead to , facilitating targeted interventions such as prism therapy, , or vision training. Despite its reliability, the test demands skilled examiners and can be time-intensive, prompting ongoing research into automated alternatives that correlate highly with PCT results.

Introduction

Definition and Purpose

The prism cover test (PCT) is an objective diagnostic procedure that quantifies ocular misalignment, or , by using s to measure the degree of deviation in prism diopters (PD). It serves as the gold standard for assessing both manifest deviations, known as tropia, and latent deviations, known as phoria, providing a precise evaluation of eye alignment under controlled conditions. This test integrates elements of the alternate with prism neutralization to determine the total deviation, which encompasses both tropia (visible misalignment) and phoria (hidden misalignment revealed upon of the eyes). The primary purpose of the PCT is to measure the magnitude and direction of horizontal, vertical, or combined eye deviations, enabling clinicians to diagnose and classify conditions such as (inward deviation), (outward deviation), and vertical . By distinguishing between near fixation (typically at 33 cm) and distance fixation (typically at 6 m), the test helps identify variations in alignment that may indicate specific underlying disorders, supporting targeted treatment planning. Unlike qualitative screening methods such as the basic , the PCT provides quantitative data essential for monitoring progression and evaluating interventions. Key concepts in the PCT include the recognition that total deviation represents the sum of tropia and phoria components, with the test dissociating the eyes to fully elicit latent elements. It is routinely performed by trained professionals, including ophthalmologists, orthoptists, and optometrists, in clinical settings to ensure accurate interpretation and reliability. This standardized approach underscores its role in establishing a for ocular motor function.

Clinical Importance

The prism cover test serves as the gold standard for objectively measuring ocular misalignment in , providing essential diagnostic value by quantifying the type ( or ) and severity of deviations in prism diopters. This precision is crucial for confirming whether the is constant or intermittent, as the test can be adapted with prolonged occlusion to reveal latent components that manifest under dissociated conditions. By differentiating these aspects, the test guides targeted interventions, including prism glasses for symptom relief, surgical planning to align the eyes, or to enhance binocular function. In clinical practice, the test's impact on treatment planning is particularly significant for managing and preventing long-term complications, such as in cases requiring to fuse images or preoperative measurements for surgery. For pediatric patients, early application of the prism cover test is vital to detect deviations that could lead to if untreated, enabling timely occlusion therapy or alignment procedures to promote normal visual development. Strabismus affects approximately 2% to 5% of the general population, underscoring the test's role in evidence-based management of common conditions like congenital , where its objectivity ensures accurate assessment and intervention to mitigate risks of sensory adaptations or loss. Compared to subjective methods like the Maddox rod, the prism cover test's reliability supports more dependable outcomes in disorder treatment.

Background

The basic cover-uncover test serves as a foundational qualitative assessment for detecting manifest , or tropia, by observing any refixation movement in the uncovered eye when one eye is covered, without the use of prisms. This test differentiates tropia from phoria by dissociating the eyes and revealing a shift in fixation if misalignment is present. The alternate cover test extends this by rapidly switching the occluder between eyes to measure the total ocular deviation, encompassing both tropia and latent phoria, though it provides only an observational estimate rather than precise quantification without prisms. This method fully dissociates , allowing estimation of the maximum misalignment angle through repeated refixations. Other alignment tests include the , which uses the position of a corneal light reflex to provide a gross qualitative estimation of eye deviation. For infants or uncooperative patients, the Krimsky test modifies this approach by placing loose prisms over the deviating or fixing eye to center the light reflex, offering a semi-quantitative measure of angle. The prism cover test builds upon these methods by incorporating prisms to neutralize observed refixations, enabling precise measurement of deviations in prism diopters for both manifest and total misalignment.

Optical Principles

Strabismus represents a misalignment of the visual axes of the two eyes, resulting from a failure of binocular fusion, which normally allows the brain to integrate images from both eyes into a single percept. Without fusion, this misalignment leads to diplopia, or double vision, as each eye fixates on a different point in space. In cases of tropia, a manifest deviation, the eyes are constantly misaligned even under binocular viewing conditions, whereas phoria denotes a latent deviation that is controlled by fusional mechanisms but becomes apparent when binocular vision is disrupted. Prisms play a central role in quantifying these deviations by altering the path of light rays entering the eye, effectively shifting the image position on the without changing the eye's position. An ophthalmic deviates light toward its base, with its power measured in prism diopters (), where 1 PD corresponds to a 1 cm deviation of light rays at a distance of 1 meter from the . This optical property allows prisms to neutralize the apparent movement of the eye during the test, providing a direct measure of the angular misalignment in PD, which is more practical for clinical use than angular degrees. The cover test relies on the principle of dissociation, where occluding one eye eliminates binocular fusion, allowing any latent deviation (phoria) to manifest as the non-covered eye moves to acquire fixation. Prisms are then introduced to counteract this refixation movement, quantifying the full extent of the deviation by determining the prism power required for neutralization. This process reveals both manifest (tropia) and latent components, as the alternate covering fully dissociates the eyes, measuring the total deviation. Fixation distance influences the measured deviation due to the coupled accommodation-convergence response, where focusing at near distances stimulates , potentially altering the phoria or tropia magnitude. For instance, in accommodative esotropia, the deviation is often larger at near than at distance, as accommodative demand increases . Measurements are thus performed at both 6 meters (distance) and 33 cm (near) to assess these variations and inform diagnosis.

Indications and Contraindications

Indications

The prism cover test is primarily indicated for the assessment of suspected or confirmed strabismus, including esotropia, exotropia, and hypertropia, where accurate measurement of ocular misalignment is essential for diagnosis and management. It serves as a gold standard method for quantifying the total deviation (including both manifest and latent components) in these conditions. Additionally, the test is recommended for evaluating phorias in patients presenting with symptoms such as headaches or asthenopia, helping to identify latent deviations that may contribute to visual discomfort. In pediatric populations, particularly children at risk for , the prism cover test is routinely used to detect and measure strabismic deviations that could impair development. For adults, indications include post-traumatic evaluation or cases of , where the test aids in determining the extent of misalignment following injury or neurological events. It is also valuable for pre- and post-surgical monitoring in correction procedures, allowing clinicians to track changes in alignment over time. The test is particularly useful for horizontal and vertical deviations up to approximately 40-50 prism diopters (PD) using standard prism bars; larger deviations may require stacking prisms, loose prisms, or alternative methods for precise quantification. It is particularly useful in scenarios requiring comparison of deviations at near and distance fixations, such as in accommodative esotropia, where differences in alignment can inform treatment decisions like spectacle correction. The dissociated variant (alternate prism cover test) measures the total deviation, while the simultaneous variant measures only the manifest tropia. Prerequisites for performing the prism cover test include patients who demonstrate central fixation on a target and the ability to cooperate with the examination, ensuring reliable results. These factors are critical in both children and adults to minimize measurement errors.

Contraindications

The prism cover test has absolute contraindications in conditions where it cannot accurately assess or measure ocular deviations. Cyclotropia, or torsional deviations, cannot be evaluated using this method, as prisms are designed to correct only horizontal and vertical misalignments, necessitating specialized tests like the double Maddox rod or . Eccentric fixation, often seen in dense cataracts or untreated , renders the test unreliable because the deviating eye maintains fixation via an off-foveal retinal point, eliminating observable refixation movements during occlusion. also constitutes an absolute contraindication, as involuntary oscillations disrupt steady fixation, obscuring the distinction between refixation saccades and nystagmic drifts. Relative contraindications apply in scenarios where the test may be feasible but yields suboptimal or imprecise results. Deviations exceeding approximately 40-50 pose challenges, as standard prism bars lack sufficient power, often requiring stacking prisms, loose prisms, or alternative quantification techniques for surgical planning. Uncooperative patients, including infants or those with neurological conditions impairing compliance, represent another relative , since the test demands consistent central fixation and patient engagement. The procedure carries minimal risks, primarily transient discomfort from repeated or prolonged , which may exacerbate in patients prone to anxiety or . Inaccuracy arises in low-vision cases or neurological disorders affecting and cooperation, potentially leading to erroneous deviation estimates. Alternatives include the Krimsky test for uncooperative individuals, which estimates deviation via corneal reflexes without requiring full . In , non-dissociative options like the simultaneous prism cover test are favored to minimize induction of latent components while assessing manifest misalignment.

Procedure

Equipment and Preparation

The prism cover test, also known as the prism and alternate cover test, utilizes specialized equipment to quantify ocular misalignment in both horizontal and vertical planes. The core instrument is a prism bar containing individual loose prisms graduated from 1 to 40 prism diopters (PD), enabling precise neutralization of deviations; horizontal prisms are fixed for base-in or base-out orientations, while vertical prisms are rotatable to assess base-up or base-down misalignment. An opaque occluder or paddle is essential for alternately covering the eyes to dissociate fixation and elicit refixation movements. Fixation targets consist of a distance chart, such as a Snellen or LogMAR acuity chart positioned at 6 meters, and a near accommodative target, typically a detailed card held at 33 cm to promote appropriate convergence. A penlight provides illumination for the fixation target, particularly useful when assessing patients with reduced visual acuity or in low-light conditions to ensure clear observation of corneal reflexes if needed. Prior to testing, the patient must be prepared to optimize accuracy and comfort. The procedure is explained in simple terms to the patient—or for children—to foster cooperation and minimize anxiety, emphasizing that the test involves covering each eye briefly while focusing on a target. The patient is seated comfortably in an examination chair with the head aligned straight and unsupported to maintain natural posture, ensuring the gaze is directed at the primary position. Best-corrected is confirmed by having the patient wear their current spectacles or contact lenses if applicable, as uncorrected refractive errors can confound deviation measurements. The examiner ensures an appropriate environment by adjusting room lighting to be bright yet glare-free, facilitating clear visualization of eye movements without shadows obscuring the fixation target. A qualitative is often performed first to estimate the approximate deviation magnitude, guiding initial selection. For safety, all equipment is cleaned with wipes between uses to prevent cross-contamination, and testing sessions with pediatric patients are monitored closely to avoid fatigue, with breaks provided if signs of discomfort or inattention arise.

Step-by-Step Method

The prism cover test begins with an initial assessment using the cover-uncover test at both distance (typically 6 meters) and near (typically 33 cm) fixation to detect the presence of a tropia, estimate its direction, and roughly gauge its magnitude by observing any refixation movement. To measure the total deviation, including both tropia and phoric components, alternate covering is then performed: the occluder is rapidly switched between the eyes, with each eye covered for several seconds (approximately 3-5 seconds) to fully dissociate and ensure the uncovered eye takes up fixation, revealing the complete misalignment. Prism neutralization follows by placing a prism bar over the deviating eye, with the apex oriented toward the direction of the deviation (base-out for , base-in for , base-up or base-down for vertical deviations); while continuing the alternate , the prism power is incrementally increased until no refixation movement is observed in the covered eye upon uncovering, at which point the minimal prism strength required for neutralization is recorded as the deviation magnitude in prism diopters. The full procedure is repeated at both distance and near to compare deviations across viewing conditions. Horizontal and vertical components are assessed separately, starting with horizontal deviation and then vertical if present, by adjusting the prism orientation accordingly during alternate covering.

Variations

The prism cover test can be modified in several ways to address specific clinical scenarios, such as isolating manifest deviations, assessing latent components, or accommodating non-cooperative patients like infants. These variations adapt the core procedure by altering the occlusion pattern, prism placement, or observation method while maintaining the goal of quantifying ocular misalignment in prism diopters (PD). The single prism cover test, also known as the simultaneous prism cover test (SPCT), measures only the manifest tropia without alternating the cover between eyes. In this variation, the prism is placed over the non-fixating eye while the fixing eye is covered, and the prism strength is adjusted until the non-fixating eye stabilizes on the target without movement; this isolates the tropic component by preserving some binocular fusion. It is particularly useful for distinguishing manifest deviations from latent ones in cases of small-angle or microtropia. The under cover test involves a prolonged period to elicit dissociated deviations. The is held in front of one eye under an occluder for 10 seconds while the patient fixates on a distant target, after which the occluder is shifted to the other eye to observe any refixation movement; strength is incrementally increased until the deviation is neutralized. This method is employed to quantify dissociated vertical deviation (DVD), often revealing larger hyperdeviations (e.g., median 7 PD) compared to standard alternate cover testing, as the extended unmasks latent components. For infants or uncooperative patients, modifications incorporate objective techniques that minimize reliance on patient compliance. The Krimsky method, a variant using loose prisms, involves shining a penlight into the eyes to observe corneal light reflexes; prisms are placed over the fixing eye (or deviating eye in some adaptations) to center the reflex in the of the misaligned eye, with the required prism power equaling the deviation magnitude. This light-reflection approach is ideal for young children, providing an estimate of angle without full occlusion. Other adaptations include photo-based methods, where photographs capture light reflexes for later prism estimation, or visuscope-assisted loose prisms to assess fixation stability. Additional variations target specific conditions like or phorias. The simultaneous prism cover test, akin to the SPCT, can be applied in to measure alignment under binocular viewing conditions by covering the fixing eye while adjusting prism over the other, helping to identify the null point without fully disrupting . For phoria estimation, base-out prisms (for esophorias) or base-in prisms (for exophorias) are incorporated during dissociated cover testing to neutralize recovery movements, allowing quantification of latent deviations. These variations are selected based on clinical needs: the single prism cover test for isolating tropia in stable fusion cases, the under cover test for latent or dissociated elements like DVD, infant modifications like for non-verbal patients, simultaneous approaches for nystagmus-related assessments, and base-in/out prisms for pure phoria evaluation.

Recording and Interpretation

Recording Conventions

The standardized notation for recording prism cover test results employs specific symbols to denote the direction and type of ocular deviation. , an inward deviation, is abbreviated as "E," while , an outward deviation, is denoted by "X." Vertical deviations use "U" for up () and "D" for down (hypotropia). Laterality is indicated by "R" for right and "L" for left, with "T" appended to signify a manifest tropia. For example, "RET 20" represents a right of 20 prism diopters (PD). Results are formatted to specify measurement conditions, distinguishing between distance (typically at 6 ) and near (at 33 cm) fixation. A common structure includes phrases such as "Distance: XT 15, Near: ," where "" indicates orthophoria (no deviation), and "XT" denotes alternating . Notations must clarify whether the measurement reflects the total deviation (via alternate , encompassing both tropia and phoria) or the manifest deviation (via , capturing only the tropia). Intermittent deviations may be marked with "(T)," as in "RX(T) 10" for right intermittent of 10 PD. Additional details in the record include the direction of the prism base used for neutralization, such as "base out" for or "base in" for , placed over the deviated eye. In cases of incomitance, where the deviation magnitude varies by position or fixation, this variability is explicitly noted, for instance, "RET 20 primary , RET 25 left ." Asymmetric deviations require separate recordings for each eye. All measurements are expressed exclusively in prism diopters (), the standard unit quantifying angular deviation.

Interpretation

The interpretation of prism cover test results involves analyzing the magnitude and direction of eye movement to diagnose the type and severity of ocular deviation, as well as assessing implications for binocular function. Orthophoria is indicated by no observable movement, corresponding to 0 prism diopters (PD) of deviation, signifying aligned visual axes under both dissociated and associated conditions. Small phorias, defined as less than 6 PD horizontally and less than 1 PD vertically, are generally considered within normal limits and do not typically impair binocular vision or require treatment. Abnormal results reveal deviations where the magnitude in PD reflects severity; for instance, deviations exceeding 15 often denote clinically significant that may cause or if untreated. The direction of the neutralizing prism or eye movement specifies the deviation type, such as right (RET) when the prism base-out neutralizes inward deviation of the right eye. Using standard notation symbols from recording conventions, like RET for right , aids in precisely classifying these findings. A key aspect of interpretation is evaluating differences between near (typically 33 cm) and distance (6 m) measurements; a disparity of ≥4 greater at near suggests , while differences >10 PD may indicate specific subtypes of intermittent or divergence insufficiency, often linked to accommodative /accommodation () ratio abnormalities. Incomitance, evidenced by variations in deviation magnitude across cardinal gazes exceeding 5-10 PD, indicates potential restrictive or paretic conditions affecting extraocular muscle function. Interpretation must account for procedural factors, such as the dissociative effect of the alternate , which eliminates and thus exaggerates the measured phoria compared to associated conditions. To refine the assessment, results are cross-referenced with subjective tests like the Maddox rod to evaluate capacity and distinguish latent from deviations. These findings directly inform clinical management; small deviations (e.g., 5-10 phorias) may be addressed with prism spectacles to restore comfort and binocularity, whereas larger tropias (e.g., >20 ) frequently necessitate surgical to realign the eyes and prevent long-term visual deficits.

Examples of Results

In a typical case of a child presenting with , the prism cover test might reveal a left esotropia (LET) of 25 prism diopters () at distance and 30 at near, indicating an accommodative component where the deviation increases with near fixation due to high accommodative convergence-to-accommodation ratio. This pattern suggests refractive accommodative esotropia, often managed initially with hyperopic correction, but persistent deviations may warrant surgical if exceeding 10-15 . For an adult with , results could show orthophoria (Ortho) at and a right (RXT) of 12 at near, pointing to a pattern suggestive of when considering intermittent control, though confirming with additional tests like the is essential for . Such findings link to intermittent subtypes, where near deviations influence decisions on observation versus prism therapy or for angles over 20 . In cases involving vertical deviations, the test post-alternate cover might demonstrate a right hypertropia (RHT) of 8 at distance, accompanied by a note on associated torsion, as excyclotorsion often coexists in superior oblique palsy-related . This result aids in diagnosing incomitant vertical , potentially guiding prism adaptation or surgical planning if the deviation persists beyond 10 and affects binocular function. Normal results from the prism cover test typically indicate at both distance and near, or a small phoria such as 2 , which falls within physiologic limits and requires no intervention. These baseline findings confirm aligned ocular posture, distinguishing asymptomatic from pathological tropia and supporting routine monitoring rather than aggressive treatment. These examples illustrate how prism cover test outcomes directly inform diagnosis and management, with larger deviations (e.g., >15 ) often indicating surgical candidacy to restore alignment and prevent .

Advantages and Limitations

Advantages

The prism cover test serves as the gold standard for objectively quantifying the total ocular deviation in , encompassing both manifest tropia and latent phoria, expressed in diopters (), which enables precise clinical assessment superior to subjective or qualitative methods. This objectivity arises from its reliance on observable refixation movements neutralized by , providing reliable measurements of misalignment without dependence on patient reports. Its versatility allows evaluation of both and vertical deviations at (typically 6 meters) and near (typically 33 cm) fixations, facilitating comprehensive diagnosis across various presentations. The test's complete dissociation via alternate covering uncovers latent components, such as phorias, that may be overlooked by non-dissociative qualitative tests like the Hirschberg method, thus revealing underlying binocular issues. With trained examiners, the prism cover test demonstrates high reproducibility, with inter-observer variability typically under 5-10 , making it essential for monitoring treatment efficacy, such as alignment changes following surgery. This consistency supports longitudinal tracking of progress in therapeutic interventions. As a involving only occlusion and prism placement, the test causes minimal discomfort and no exposure to radiation, rendering it suitable for patients of all ages who can cooperate with fixation tasks.

Disadvantages

The prism cover test is highly dependent on the examiner's skill and experience, as accurate neutralization of the deviation requires precise observation of eye movements, leading to potential inter-observer variability of up to 12.5 prism diopters in measurements. can also influence results, particularly in subtle deviations, making the test less reliable when performed by novice examiners. The procedure is time-consuming, often leading to fatigue for both the patient and examiner, and poses significant challenges for uncooperative individuals such as young children or those with cognitive impairments. It requires sustained patient cooperation and foveal fixation, which may not be achievable in such cases. Due to the dissociation induced by alternating cover, the test can exaggerate the total ocular deviation by including both manifest tropias and latent phorias, potentially overstating the in real-world binocular viewing conditions. This limitation is particularly relevant for assessing phorias, where the measured angle may not reflect the controlled state under fusion. The test is not suitable for measuring cyclotorsion or torsional deviations, as it primarily quantifies horizontal and vertical misalignments. For very large deviations exceeding 80 diopters, standard prism bars become impractical, often requiring dual prism setups that reduce precision and increase procedural complexity. Equipment such as prism bars can be cumbersome, as the examiner must simultaneously manage , prism placement, and eye observation, which compromises reliability in dynamic settings. Additionally, the test's accuracy diminishes with poor fixation or conditions like , where stable gaze cannot be maintained.

Clinical Considerations

When performing the prism cover test, patient factors play a crucial role in obtaining reliable results. To ensure fatigue-free sessions, examiners should monitor for signs of tiredness, such as reduced fixation stability, and limit testing duration, particularly in children or those with challenges. For pediatric patients, engaging fixation targets like or age-appropriate images help maintain and during the procedure. If results appear inconsistent, retesting after a short break or using alternative engagement methods is recommended to account for variability in patient response. Examiner tips enhance the accuracy of the prism cover test. The occluder should be held in place for 3-5 seconds during alternate to allow full and recovery of fixation, enabling clear observation of refixation movements. Both eyes must be closely observed for subtle or drifts, as these can indicate latent deviations not immediately apparent in tropia. Combining the test with broader examinations, such as ductions and , provides a more comprehensive assessment of ocular alignment. Key precautions minimize errors and patient discomfort. The test should be avoided in cases of acute ocular pain, as it may exacerbate symptoms or compromise fixation. Monitoring for suppression is essential, especially in strabismic patients, by noting absent refixation movements that suggest binocular inhibition. Standardizing testing distances—at 6 meters for distance and 33 cm for near—reduces accommodative influences and measurement variability. As of 2025, integrating digital tools such as simulations or AI-based video oculography supports automated recording and analysis of prism cover test results, improving precision in clinical settings. For dissociated vertical deviation (DVD), variations like a standardized 10-second prism under cover test yield more accurate measurements than standard alternate cover by allowing full manifestation of the deviation. Skill training for examiners emphasizes repeated practice in recognizing subtle movements and neutralizing prisms to build proficiency. Additionally, addressing cultural or language barriers through clear, translated explanations ensures patient understanding and cooperation.

References

  1. [1]
    Cover Tests - EyeWiki
    Sep 19, 2025 · The examiner performs the alternate cover test while changing the prism over the deviated eye until the misalignment is neutralized.Diagnostic Procedures · Cover-Uncover Test · Alternate Cover Test
  2. [2]
    Automated assessment of ocular deviations using a consumer ...
    Purpose : The clinical gold-standard for detecting strabismus and measuring ocular alignment are the cover/uncover test and the prism alternate cover test (PACT) ...
  3. [3]
    Automated strabismus evaluation: a critical review and meta-analysis
    The gold standard measurement of ocular misalignment is achieved by using single and alternate cover tests and prisms, with alignment usually reported in prism ...
  4. [4]
    To compare horizontal strabismus deviation as assessed from ...
    Jul 29, 2024 · Conclusion. At present, the alternate prism cover test is the gold standard to measure the quantum of deviation in patients with strabismus.
  5. [5]
    Prisms - StatPearls - NCBI Bookshelf - NIH
    A prism is a transparent, triangular refracting surface with an apex and a base.[1] The two nonparallel surfaces intersect at an angle called the apex, ...
  6. [6]
    Usefulness Assessment of Automated Strabismus Angle ...
    Currently, the gold standard for assessing eye deviation is the cover–uncover test and the prismatic cover–uncover test, in which prism bars are additionally ...
  7. [7]
    INTERMITTENT EXOTROPIA: A Major Review
    A prolonged alternate cover testing should be used in patients with intermittent exotropia to suspend tonic fusional convergence.
  8. [8]
    Perfecting Prism - Review of Optometry
    Aug 15, 2019 · Prism can be a powerful treatment for many conditions and for many patients, specifically for those who suffer from asthenopia or diplopia.
  9. [9]
    How to Prescribe a Prism for Combined Vertical and Horizontal ...
    Nov 1, 2008 · This simple method can help alleviate diplopia symptoms in patients with oblique strabismus. 1 Moore, S. and L.
  10. [10]
    Esotropia - StatPearls - NCBI Bookshelf
    Jun 11, 2023 · Congenital esotropia outcomes primarily depend on treatment compliance in the form of patching to prevent amblyopia till a surgical ...
  11. [11]
    Strabismus - StatPearls - NCBI Bookshelf
    The prevalence of strabismus is 2% to 5% in the general population.[13][14]. In the U.S., 5 to 15 million individuals are affected by strabismus. In a ...
  12. [12]
    Infantile Esotropia - EyeWiki
    Apr 16, 2025 · Detection of fixation preference for one eye can be performed by the use of vertical prism test (10-prism diopter test).Disease Entity · Diagnosis · Physical Examination · Management
  13. [13]
    The Dos and Don'ts of Binocular Vision Testing - Review of Optometry
    Jan 15, 2021 · Prism bars or loose prisms should be added until no movement is seen on cover testing or the patient reports an orthophoria position on the ...
  14. [14]
    Cover Tests - EyeWiki
    Sep 19, 2025 · The cover test can be used to screen for strabismus. The results depicted here indicate a right esotropia. When the left eye is covered, the right eye moves ...
  15. [15]
    Alignment Assessment (Hirschberg) - Moran CORE
    The Hirschberg test (also known as the corneal light reflex test) is a quick and simple way to check ocular alignment.
  16. [16]
    Sensory and Motor Testing - EyeWiki
    Oct 29, 2025 · The strabismus measurement is equal to the amount of prism necessary to center the corneal light reflex on the pupil of the deviating eye.
  17. [17]
    Ocular motility disorders and strabismus - Knowledge @ AMBOSS
    Apr 9, 2025 · Failure to detect or adequately treat strabismus may result in irreversible amblyopia! ... Diplopia (double vision): most pronounced when ...
  18. [18]
    Optical Issues in Measuring Strabismus - PMC - NIH
    This articles reviews basic as well as guiding principles of prism optics and optics of the eye to equip the reader with the necessary know-how to avoid ...
  19. [19]
    Accommodative Esotropia - EyeWiki
    Apr 16, 2025 · Accommodative convergence describes the normal convergence of the eyes in response to accommodation of the lens.
  20. [20]
    None
    Summary of each segment:
  21. [21]
    Ocular Deviation - Wiley Online Library
    Nov 30, 2013 · The prism cover test is used objectively and is the method of choice ... However, cyclotropia cannot be measured by this method.
  22. [22]
    Management of nystagmus in children: a review of the literature and ...
    In the presence of nystagmus, the cover test will be more difficult to perform as small movements to take up fixation can be impossible to distinguish. ...Missing: unreliable | Show results with:unreliable
  23. [23]
    Effective prism diopter for strabismus measurement:...
    In clinical ophthalmology, prisms, commonly made of glass, are labeled based on the prism diopter (PD) value measured in the anterior Prentice position.
  24. [24]
    Measurement of Strabismic Angle Using the Distance Krimsky Test
    Jul 18, 2013 · The distance Krimsky test is expected to be more useful than the Krimsky test in measuring the distance angle of deviation for patients with strabismus.
  25. [25]
    How to Perform a Basic Cover Test in Ocular Misalignment or ...
    Apr 24, 2015 · This test is performed by placing prism of varying strength that is oriented in the appropriate direction for the deviation over the non- ...
  26. [26]
    [PDF] Wright's Strabismus Review Crazy Easy
    The alternate cover test keeps binocular fusion suspended as one eye ... If simultaneous prism cover test measures esodeviation 5 PD and prism alternate cover ...
  27. [27]
    Inter-observer Reliability of the Prism and Alternate Cover Test in ...
    We report inter-observer test-retest reliability of the PACT and modified Krimsky test at near in children 60 months of age or younger with esotropia.
  28. [28]
    [PDF] IOWA BASIC SCIENCE NOTES Strabismus 2017 William E. Scott ...
    Single prism cover test. b. Simultaneous cover and prism test. c. Alternate cover and prism test. 3. Scleral comparison. 4. Subjective detection. *Larson SA ...
  29. [29]
    a descriptive study using the ORTe EYENAC eye-tracking system
    May 6, 2025 · Ocular deviation is often quantified using the alternate prism cover test (APCT) and single prism cover test (SPCT). The APCT can quantify ...
  30. [30]
    Strabismus Measurements Using the Alternating and Simultaneous ...
    Sep 1, 2001 · The simultaneous prism cover test generally is used to measure microtropia when a latent component is present.3 It is an important technique ...
  31. [31]
    Role of a Standardized Prism Under Cover Test in the Assessment ...
    Feb 2, 2018 · A standardized 10-second prism under cover test yields greater values than a prism and alternate cover test in the majority of patients with DVD.
  32. [32]
    Krimsky test - American Academy of Ophthalmology
    Krimsky test. Prism is placed in front of the deviating eye to correct the deviation of the corneal light reflex.
  33. [33]
    Assessment of Binocular Vision and Accommodation - Clinical Gate
    Aug 3, 2015 · The alternating cover test cannot be used alone to evaluate whether a patient has a heterotropia as the pattern of eye movements observed during ...
  34. [34]
    [PDF] Strabismus Terminology and Abbreviations
    4 Abbreviated “PD”. Examples: • Esophoria: E. • Alternating Exotropia: XT, or alt XT. • Left hypotropia: LHoT, or ...
  35. [35]
    [PDF] 17-2021 CAMI Pilot Vision brochure - Federal Aviation Administration
    One prism diopter of hyperphoria, six prism diopters of esophoria, and six prism diopters of exophoria represent FAA phoria (deviation of the eye) standards ...Missing: limits | Show results with:limits
  36. [36]
    The Many Facets of Prism In Ophthalmic Lenses - 20/20 Magazine
    Approximately 68 percent of adults have 0 prism diopters (orthophoria) to 6 prism diopters exophoria at near. Sometimes, a patient's phoria is within the ...
  37. [37]
    [PDF] strabismus.pdf - Renaissance School of Medicine
    Horizontal deviations greater than 10 prism diopters are usually clinically significant, whereas vertical strabismus may be problematic at much lower amplitudes ...
  38. [38]
    Strabismus | Exotropia - Esotropia | Cover test - Geeky Medics
    May 16, 2020 · The prism cover test is used to measure the angle of deviation of a small-angle tropia. The magnitude of the tropia is estimated from the cover ...
  39. [39]
    Convergence Insufficiency - EyeWiki
    Apr 29, 2025 · Normal convergence amplitudes are 38 prism diopters at near and 14 prism diopters at distance. In general, fusional convergence ...Missing: phoria | Show results with:phoria
  40. [40]
    Sensory and Motor Testing - EyeWiki
    Oct 29, 2025 · If the light reflex is decentered a prism is placed in front of the deviating eye or the fixating eye (modified Krimsky test) to correct the ...
  41. [41]
    Back to the Basics, Part 1: Prime Yourself to Prescribe Prism
    Feb 15, 2008 · Prism is a viable option for treating patients with symptomatic binocular vision disorders. However, prisms may not work well for all patients ...
  42. [42]
    Successful prism treatment for cyclic esotropia: A case report
    Correcting latent deviation using a prism lens is a simple approach without potential side effects. The present findings suggest that this approach is a viable ...Missing: congenital | Show results with:congenital
  43. [43]
    Refractive Accommodative Esotropia. EyeRounds.org
    Jan 26, 2011 · Generally, in refractive accommodative esotropia, the deviation is between 20 and 30 prism diopters, the deviation is similar in the distance ...January 26, 2011 · Visual Acuity Without... · Discussion
  44. [44]
    Clinical Characteristics of Patients with Intermittent Exotropia ... - NIH
    Basic-type exotropia was defined as a distance-near difference less than 10 prism diopters (PD). Divergence excess (DE)-type exotropia was defined as a distance ...Missing: ortho | Show results with:ortho
  45. [45]
    Hypertropia - EyeWiki
    Jul 30, 2025 · For example, on alternate cover testing, the right eye would drift upward when covered and be seen to come down when the left eye is covered.
  46. [46]
    Defining Real Change in Prism-Cover Test Measurements - NIH
    Based on 95% limits of agreement half-widths between two examiners, a change in strabismus measurements of less than 10 pd may be due to test-retest ...Missing: nystagmus eccentric
  47. [47]
    Principles of Strabismus Surgery for Common Horizontal and ...
    Feb 24, 2016 · This chapter aims to describe indications for strabismus surgery, planning for a successful surgery result, and do's and don'ts for effective surgical ...
  48. [48]
    The Prism Bar-Prentice and Frontal Positions - Nature
    The measurements obtained are used for both calculating the amount of correction needed in strabismus surgery, and monitoring any change in ocular alignment ...
  49. [49]
    Comparison of measurements between manual and automated...
    ... prism cover test. The main disadvantages, however, are the long duration of the test; the associated difficulty in performing the test in babies, toddlers ...
  50. [50]
    Virtual reality-based Harms tangent screen test for strabismus ...
    Jan 6, 2025 · A prism cover test allows objective measurement of the horizontal and vertical deviations but not of the torsional misalignment. One of the ...
  51. [51]
    Pediatric Exams Made Easy - Review of Optometry
    May 15, 2023 · Younger children should be engaged in a target of interest while using your thumb to perform the cover test. For the uncooperative child ...
  52. [52]
    Automated strabismus detection and classification using deep ...
    Jan 31, 2025 · This research presents a new deep-learning-based approach for automatically identifying and classifying strabismus from facial images.Missing: digital | Show results with:digital