Fact-checked by Grok 2 weeks ago

Utilization categories

Utilization categories are standardized classifications defined in the IEC 60947 series of standards for low-voltage and controlgear, encompassing devices such as contactors, breakers, and relays. These categories delineate the type of —ranging from resistive to inductive—and the associated operational duty cycles, including switching frequencies, making and breaking capacities, and power factors, to facilitate the precise selection of equipment that ensures safe and efficient performance in industrial and commercial electrical systems. The primary objective of utilization categories is to simplify the engineering process by providing predefined criteria based on real-world applications, thereby preventing overloads, enhancing equipment , and complying with norms without necessitating custom specifications between manufacturers and users. By accounting for factors like voltage, current, and load characteristics during switching operations, these categories promote reliability in diverse scenarios, from to management. They are integral to standards such as IEC 60947-4-1 for contactors and motor starters, and IEC 60947-5-1 for control circuit devices. Utilization categories are segregated into alternating current (AC) and direct current (DC) groups, with specific subcategories reflecting common load types and switching demands. The following table summarizes the principal AC and DC categories, their typical applications, and key characteristics: These classifications extend to specialized uses, such as AC-6a/b for transformers and capacitors, and DC-13 for electromagnets, underscoring their versatility across power distribution and sectors.

Fundamentals

Definition and Scope

Utilization categories classify low-voltage switching devices, such as contactors and breakers, based on the nature of the load they are intended to switch, the associated operating conditions, and the expected performance characteristics during making and breaking operations. These categories represent a combination of specified requirements that ensure the device fulfills its purpose under defined conditions, grouping practical applications into characteristic sets to guide selection and application. By standardizing these classifications within the IEC 60947 series, engineers can match devices to specific electrical loads and duties without extensive custom testing. The scope of utilization categories primarily encompasses low-voltage switchgear and controlgear rated up to 1000 V AC or 1500 V DC, addressing a range of load types including resistive, inductive, capacitive, and motor circuits. These loads influence critical aspects of device operation, such as arcing during interruption, the ability to handle inrush currents, and overall durability under repeated switching. For instance, inductive loads like motors generate higher transient voltages upon disconnection compared to resistive loads like heaters, necessitating categories that account for such differences to prevent excessive wear or failure. A key concept is the distinction between utilization categories, which focus on individual device performance under specific load and switching conditions, and coordination types, which pertain to system-level short-circuit protection and post-fault operability. Symbols such as or denote these categories, indicating suitability for particular applications without implying universal performance. This framework ensures device suitability, for example, by differentiating categories for high-inrush motor starting from those for steady-state lighting control, thereby enhancing reliability in diverse electrical systems.

Purpose and Importance

Utilization categories serve as a standardized within the IEC 60947 series to align the performance capabilities of low-voltage and controlgear devices, such as contactors and circuit breakers, with the specific characteristics of electrical loads and operational demands. By classifying devices based on load types (e.g., resistive, inductive, or motor-driven) and duty cycles, these categories ensure that equipment can safely handle critical operations like starting, stopping, or reversing loads without risking overheating, excessive mechanical wear, or premature failure. This matching process is essential for preventing operational disruptions and extending equipment lifespan, as devices rated for inappropriate categories may exceed their thermal or electrical limits during high-stress events. The importance of utilization categories lies in their contribution to overall and reliability, particularly by mitigating hazards associated with inrush currents that can reach 4-8 times the steady-state current for direct-on-line motor starting or up to 10 times for certain inductive loads. Proper categorization guides the selection of devices capable of managing these surges and associated voltages during switching, thereby reducing the likelihood of insulation breakdown or contact erosion that could lead to faults. In settings, this enhances by minimizing risks from electrical failures, while also supporting compliance with international regulations for low-voltage installations across commercial, , and residential applications. Furthermore, utilization categories promote and cost-effectiveness by enabling precise device ratings that avoid over-specification, which would otherwise increase initial costs and due to oversized components. For instance, in systems like conveyor belts driven by squirrel-cage , selecting the appropriate (such as AC-3) optimizes performance under frequent cycling, potentially achieving up to 1.3 million operational cycles while minimizing energy losses from inefficient starting methods. This not only reduces —critical in continuous processes—but also ensures equipment , as categories specify for 10^4 to 10^6 operations depending on the load and , fostering sustainable and economical electrical system design.

Standardization Framework

IEC 60947 Series Overview

The IEC 60947 series is an developed by the (IEC) for low-voltage and controlgear, encompassing parts 1 through 9 (with subparts) that establish requirements for devices operating at voltages not exceeding 1,000 V AC or 1,500 V DC. Part 1 outlines general rules and common safety requirements applicable to all devices in the series, including definitions, classifications, and performance criteria. Part 4-1 specifically addresses electromechanical contactors and motor-starters, detailing utilization categories to ensure devices are matched to specific load types, such as motors or resistive loads, thereby supporting safe and efficient operation in electrical systems. Utilization categories in the series are defined through rigorous test sequences that evaluate key performance aspects, including make-and-break capacities under rated conditions, short-circuit withstand strength, and sustained operational performance during frequent cycles. These tests simulate real-world conditions to verify that devices can interrupt currents without excessive wear or failure, incorporating parameters like operational voltage, current, and for applications or time constants for . The categories emphasize conceptual matching of device capabilities to load characteristics, prioritizing reliability over exhaustive listings of all possible scenarios. The structure of categories uses a with "AC-" or "DC-" prefixes followed by a number (e.g., AC-3 for squirrel-cage motor starting and disconnecting), often including subclasses like "A" or "B" to denote variations in short-time withstand or selectivity features. Additional requirements cover climatic withstand (e.g., temperature and humidity ranges per ), insulation coordination to prevent breakdowns, and mechanical endurance for millions of operations, ensuring durability across industrial environments. First published in , the series has evolved through multiple editions to integrate , such as semiconductor-based controllers in Part 4-2, enhancing for variable-speed drives. It is harmonized with European Norm () equivalents and Underwriters Laboratories (UL) standards, promoting and in global markets.

Historical Evolution and Updates

The utilization categories within the IEC 60947 series originated from earlier international standards for low-voltage and controlgear, such as IEC 60158 () for contactors and IEC 60292 (1969) for circuit-breakers, which addressed basic requirements for and switching during the post-World War II industrialization boom that demanded reliable, standardized electrical systems across growing industrial sectors. National standards, including those from the VDE in (e.g., VDE 0660 series for low-voltage ), also contributed foundational concepts for load-specific performance ratings, influencing the push for global harmonization to support and equipment . The modern framework began with the introduction of the IEC 60947 series in 1988, replacing fragmented predecessors, and the first edition of IEC 60947-4-1 in 1990, which defined initial utilization categories for AC and DC applications in electromechanical contactors and motor-starters, focusing on non-inductive, resistive, and inductive loads to ensure safe operation under specified conditions. This edition established core categories like AC-1 through AC-4 for alternating current and DC-1 through DC-3 for direct current, emphasizing performance verification through type tests for making and breaking capacities. Key revisions followed to adapt to emerging technologies. The second edition of IEC 60947-4-1 in 2000, along with Amendment 1 in 2002, expanded categories to cover , introducing AC-5 and AC-6 for switching capacitors and transformers, reflecting the rise of electronic loads in industrial automation. A 1999 amendment to related parts of the series addressed fusing protections in control circuits, enhancing reliability for devices integrating solid-state components. The third edition in 2009 and its Amendment 1 in 2012 further refined test procedures and category assignments based on experimental validation of load behaviors. Subsequent updates have responded to broader influences, including efforts with ISO standards for environmental testing and regional norms like NEMA in the United States, which facilitated cross-market adoption while addressing technological shifts such as variable frequency drives that alter inductive load dynamics during starting and stopping. The fourth edition in 2018 introduced technical revisions, including clarified scope exclusions and updated normative references, to better align with evolving grid requirements and controlgear integration. The fifth edition, published in 2023, continues this progression with further refinements to electromechanical and motor protective devices, including incorporation of new DC-PV utilization categories (e.g., DC-PV0 for disconnecting under load, DC-PV1 for switching under no-load, and DC-PV2 for infrequent switching) to support photovoltaic and applications. Ongoing developments under IEC Technical Committee 121 focus on integrating utilization categories with , including , local generation, and smart management, with recent updates to other parts of the series such as IEC 60947-2 (2024) for circuit-breakers and IEC 60947-5-1 (2025) for control circuit devices, as of November 2025.

Alternating Current (AC) Categories

Core AC Categories (AC-1 to AC-4)

The core AC utilization categories, designated AC-1 through AC-4 in the IEC 60947-4-1 standard, define the performance requirements for contactors handling common alternating current loads, particularly in motor control applications. These categories specify the making and breaking capacities under defined test conditions, ensuring devices can withstand electrical and mechanical stresses associated with specific operations like starting, stopping, and reversing. Test protocols typically involve up to 600 operations per hour, with endurance measured in operating cycles, such as approximately 1 million cycles for AC-3 applications. AC-1 applies to non-inductive or slightly inductive loads, such as resistive furnaces, heating elements, or incandescent lamps, where switching involves simple on/off control with minimal —typically no more than the rated operational current (I_e). These loads exhibit a high greater than 0.95 and operate under continuous duty, resulting in low switching surges and extended device lifespan, often in the range of thousands of operations. Contactors rated for AC-1 prioritize reliability for steady-state applications without significant arcing during interruption. AC-2 is designated for slip-ring induction motors, encompassing starting with rotor resistors, switching off during running, and operations like plugging or inching that involve moderate inrush currents up to 2.5 times I_e. This category accommodates reversing and high starting torque scenarios, with a maximum of 120 starts per hour under short-time duty conditions. Endurance is lower than AC-1 due to the inductive nature of the loads, but it suits applications requiring controlled acceleration in wound-rotor motors. AC-3 targets squirrel-cage induction motors for starting and switching off during running, handling high inrush currents of 4 to 8 times I_e while interrupting at or near zero current to minimize arcing. Typical test conditions include 12 to 15 starts per hour, with a maximum start time of 15 seconds and reduced voltage (about 17% of rated) during coasting to stop. This category is widely used for standard , offering endurance of around 500,000 to 1.3 million operating cycles, depending on the device —for instance, up to 1.3 million cycles for a 15.5 A . AC-4 extends to squirrel-cage motors involving frequent starting, plugging (rapid reversal), or inching, demanding higher making and breaking capacities at full voltage to manage inrush currents up to 6 times I_e and elevated switching frequencies of up to 600 operations per hour. These dynamic operations impose greater mechanical and electrical stress, resulting in reduced , such as 100,000 to 200,000 cycles for a 29 A device. AC-4-rated contactors are essential for applications requiring precise, high-cycle but often necessitate oversized units to achieve reliable performance.
CategoryTypical LoadsKey OperationsInrush Multiple (× I_e)Operations/Hour (Max)Endurance (Cycles, Approx.)
AC-1Resistive heating, lampsOn/off switching≤1ContinuousThousands+
AC-2Slip-ring motorsStarting, plugging, off during run≤2.5120Hundreds of thousands
AC-3Starting, off during run4–812–15 (up to 600)500,000–1.3 million
AC-4Frequent start/plug/inch≤6600100,000–200,000

Specialized AC Categories (AC-5 to AC-23)

Specialized AC utilization categories from AC-5 to AC-23 address switching demands of non-motor loads, such as , transformers, capacitors, and electromagnetic devices, which impose unique stresses like high inrush currents and restriking voltages beyond those in core motor categories (AC-1 to AC-4). These categories are defined in the IEC 60947 series, primarily IEC 60947-4-1 for contactors and IEC 60947-5-1 for controlgear, with AC-20 through AC-23 specified in IEC 60947-3 for switches and disconnectors. They ensure devices can handle specific load characteristics, including magnetizing inrush and recovery voltages, while limiting operational cycles due to arc and . The AC-5 categories focus on lighting loads. AC-5a applies to switching lamps, such as fluorescent lighting, where compensation capacitors cause high inrush currents during starting, and restriking voltages occur upon interruption due to the lamp's characteristics. AC-5b covers incandescent lamps, accounting for inrush currents up to 15 times the rated (I_e) from the cold 's low resistance, followed by restriking voltage peaks during breaking. These categories require devices rated for 6000 operating cycles at power factors of 0.9 for AC-5a and 1.0 for AC-5b, emphasizing quenching to prevent damage. AC-6 categories handle reactive components in power systems. AC-6a is for switching transformers, managing magnetizing inrush currents up to 30 times I_e and de-energization recovery voltages that can reach twice the supply voltage, stressing contacts with high making capacity requirements. AC-6b addresses capacitor banks for power factor correction, involving inrush currents of 10 to 30 times I_e at frequencies of 2 to 6 kHz, along with high restriking voltages during de-energization due to stored energy discharge. Operational limits are stricter, with approximately 10,000 cycles permitted for AC-6b owing to the severe electrical and mechanical stress on arc chutes and contacts. The operational current for AC-6b is derived as 0.45 times the AC-3 rating up to 100 A. AC-7 categories target and low-inrush applications. AC-7a suits slightly inductive or resistive loads, such as in mixers or blenders, with low inrush currents and moderate overloads at a power factor of 0.80. AC-7b extends to motor loads in appliances, involving higher but still limited inrush compared to motors, at a power factor of 0.35. These are rated for frequent operating cycles suitable for use and are increasingly applied to modern switched-mode power supplies with minimal inrush, providing a bridge between resistive and inductive switching needs. AC-15, defined for controlgear in IEC 60947-5-1, governs switching of electromagnetic loads exceeding 72 , such as solenoids, electromagnetic brakes, and clutches. It emphasizes handling high inductive kickback voltages—up to several times the supply voltage—during interruption, requiring robust and to mitigate contact erosion. Devices must perform 6,000 cycles at a of 0.80, with inrush currents significantly higher than steady-state values. The AC-20 to AC-23 categories cover mixed and combination loads in switch-disconnectors per IEC 60947-3, suitable for isolation and occasional control. AC-20 involves connecting and disconnecting under no-load conditions, with no inrush or breaking stress. AC-21 handles resistive loads, including moderate overloads. AC-22 addresses mixed resistive and inductive loads, such as those with resistors or capacitors in series. AC-23 is for motor loads or highly inductive circuits, permitting occasional individual motor switching with high inrush handling; the "A" suffix denotes frequent operations (e.g., >10 per hour), while "B" indicates infrequent use. These categories apply to circuit breakers in IEC 60947-2, where fewer operations (e.g., 10^4 cycles for high-stress AC-6b equivalents) reflect the arc and thermal demands in protective applications.

Direct Current (DC) Categories

Core DC Categories (DC-1, DC-3, DC-5, and DC-6)

The core DC utilization categories, as defined in IEC 60947-4-1, specify the performance requirements for low-voltage contactors and motor starters handling resistive and inductive loads in systems, focusing on making and breaking capacities under defined conditions such as current multiples (e.g., 1 to 4 times the rated operational current I_e) and time constants (L/R values). These categories address the challenges of DC switching, where arcs persist without the natural zero-crossing of , necessitating specialized designs for arc extinction. Unlike AC categories, which benefit from sinusoidal waveform recovery voltage, DC categories emphasize inductive load management through parameters like L/R ≤ 1 ms for low-inductance cases up to 15 ms for high-inductance motors. DC-1 covers non-inductive or slightly inductive loads, such as resistors and DC heating elements like resistance furnaces, where switching involves minimal arcing due to low inductance (L/R < 1 ms). This category requires contactors to handle making and breaking at 1.5 × I_e with a power factor of 1, suitable for steady-state resistive applications without significant inrush currents. It represents the simplest DC load type, analogous to AC-1 but without frequency-dependent effects, and is commonly used in heating systems or basic control circuits. DC-3 is designated for shunt-wound DC motors involving starting, reversing, inching, and dynamic braking, accommodating higher inrush currents during startup (up to 4 × I_e) and moderate inductance (L/R ≤ 2 ms). It requires robust arc quenching for operations like plugging (rapid reversal) and inching (short jogs), common in industrial machinery such as cranes or hoists needing precise speed control. Compared to simpler motor operations, DC-3 imposes stricter test sequences, including 50 cycles of mixed making and breaking under load, to ensure performance under frequent directional changes. Contactors rated for DC-3 can also handle basic starting and stopping of shunt motors. DC-5 is for series-wound DC motors requiring starting, reversing, inching, and dynamic braking, with the highest inductive interruption demands among motor categories (L/R ≤ 15 ms). Contactors must manage severe arcing from rapid reversals and braking, tested at 4 × I_e for making and breaking, making it essential for high-torque applications like electric vehicles or elevators. This category extends principles to series excitation, where field and armature currents interact strongly, necessitating advanced contact materials for endurance. Contactors rated for DC-5 can handle basic starting and switching off while running for series motors. DC-6 pertains to switching incandescent lamps and small DC transformers, accounting for filament inrush surges (up to 10-15 times steady-state current) despite primarily resistive characteristics. It involves low making/breaking multiples (1.5 × I_e) but tests with extended off-times (e.g., 8 s) and polarity reversals to simulate real-world lighting loads, suitable for battery-powered or rail systems. Unlike motor categories, DC-6 emphasizes surge tolerance over inductance, with applications in signaling or auxiliary illumination where frequent cycling occurs. These core categories are generally limited to configurations with up to four poles connected in series to facilitate arc extinction through voltage division, a necessity in DC due to the lack of natural current interruption. Endurance is verified under IEC 60947-4-1 for a minimum of 6,000 operating cycles in conventional tests, typically lower than AC equivalents (e.g., 10,000+ for AC-3) because sustained DC arcs accelerate contact wear despite similar mechanical life ratings. This reflects the fundamental challenge of DC arc persistence, influencing device selection for safety and longevity in resistive-to-highly inductive environments.

DC-Specific Considerations

Direct current (DC) switching presents unique challenges compared to alternating current (AC) due to the continuous nature of DC flow, which lacks natural zero-crossing points to aid arc extinction. In DC systems, arcs formed during interruption do not self-extinguish as they do in AC circuits at current zeros; instead, they persist until actively quenched, potentially leading to contact erosion, welding, or failure if not managed properly. To address this, devices often incorporate , which generate a magnetic field to rapidly displace the arc into de-ionizing chambers or plates, elongating and cooling it for effective interruption. Alternatively, series connection of multiple poles (typically 2-3) increases the arc gap length, distributing the voltage across poles to facilitate extinction, particularly for higher voltages. Polarity plays a critical role in DC utilization, as standard categories are defined assuming positive polarity relative to the load. This assumption influences arc behavior and breaking capacity, with inductive loads showing reduced performance if polarity is reversed due to varying electromagnetic forces on the arc. For bidirectional switching applications, where current direction may reverse (e.g., in energy storage systems), devices require specialized designs or dual ratings to ensure safe interruption in both polarities, often achieved through symmetric contact arrangements or bi-directional contactors that maintain performance regardless of flow direction. Voltage limits for DC categories are generally constrained to low-voltage ranges, with IEC 60947 standards covering circuits up to 1500 V DC for contactors and starters. Preferred nominal DC voltages include 24 V, 48 V, 110 V, and 220 V, commonly used in industrial and utility applications; exceeding 60 V typically necessitates series pole configurations to handle the increased arc voltage. Higher voltages beyond 1500 V demand specialized high-voltage DC devices, such as those with advanced arc chutes, to prevent sustained arcing. The categories and requirements are consistent in the latest IEC 60947-4-1:2023 edition, which applies to circuits up to 1500 V DC. DC categories are integral to various systems, including railway electrification (e.g., 110 V or 220 V traction supplies), renewable energy setups like solar inverters (where DC isolators manage string voltages up to 1000 V), and battery storage systems (often at 24 V or 48 V for vehicles and utilities). In rectified AC-to-DC conversions, such as frequency converter intermediate circuits, residual ripple must be considered, as it can mimic AC behavior and affect switching ratings, requiring devices rated for the effective DC value plus ripple amplitude. For control circuit devices, IEC 60947-5-1 specifies additional DC categories beyond core power switching, including DC-13 for controlling electromagnets (e.g., solenoids and relays) and DC-14 for electromagnetic loads with economy resistors to limit inrush currents. These low-power categories ensure reliable signaling and actuation in automation systems. The 2018 edition of IEC 60947-4-1 extended coverage to 1500 V DC, facilitating applications in emerging fields like electric vehicle infrastructure by accommodating higher-voltage contactors for charging systems.

Practical Applications

Device Selection and Matching

The selection of switching devices, such as contactors and circuit breakers, under IEC 60947 utilization categories begins with a thorough assessment of the load type, including whether it is resistive, inductive (e.g., motors or capacitors), or involves high inrush currents like transformers. Operating frequency must also be evaluated, typically 50/60 Hz for AC loads, with adjustments for non-standard frequencies that could impact thermal and switching performance. Environmental conditions, such as ambient temperature and altitude, further influence selection to prevent derating issues. The chosen category must align with the device's rated operational current (I_e), ensuring it exceeds peak demands like starting currents by a safety margin to maintain reliability. Matching devices to specific applications involves selecting categories that match the load's duty cycle and characteristics; for instance, an AC-3 rated contactor is suitable for squirrel-cage pump motors with up to 10 starts per hour, as it handles starting currents of 6-8 times the rated load while allowing disconnection during running. In uninterruptible power supply (UPS) systems, an AC-6a category device is appropriate for switching transformer primaries, accommodating inrush currents up to 18-30 times the rated current without excessive arcing or wear. These examples emphasize prioritizing categories from the AC series for inductive loads, as defined in IEC 60947-4-1, to optimize performance and longevity. For DC loads, select categories like DC-3 for shunt motors, considering higher arcing risks and specific breaking capacities per IEC 60947-4-1. Key factors in the selection process include coordination with protective devices like fuses or circuit breakers to achieve Type 1 or Type 2 short-circuit coordination, where the contactor withstands the let-through energy without damage. Derating is essential for challenging environments; for example, at altitudes above 2000 m, apply a factor of 0.95 at 3000 m to the thermal current rating, and reduce by 10% for temperatures exceeding 40°C. Software tools, such as temperature-rise calculators based on IEC 60890 or life-span simulators, aid in modeling these effects for precise matching. For safety, devices are often oversized by 20-50%—equivalent to selecting the next frame size—to accommodate heavy-duty starts or high inrush, enhancing short-circuit withstand capacity. IEC 60947 recommends verifying custom applications through type tests, including making and breaking capacity assessments under specified conditions, to confirm the device's suitability for the matched utilization category and load. This verification ensures the selected device meets operational performance requirements without relying solely on catalog ratings.
FactorConsiderationExample Derating/Adjustment
Load TypeInductive (motors) vs. CapacitiveAC-3 for motors: Starting current ≈6-8 × I_e; select I_e ≥ motor I_e
EnvironmentTemperature >40°CReduce I_th by 10% at 50°C
CoordinationWith fusesType 2: intact post-fault, up to 65 kA

Testing, Compliance, and Safety

Testing of low-voltage and controlgear under the IEC 60947 series involves both routine tests and type tests to verify performance in accordance with specified utilization categories. Routine tests, conducted by manufacturers on each device, ensure manufacturing consistency and include checks for properties, functional operation, and protection against residual currents. Type tests, performed on representative samples, assess overall suitability and encompass making and breaking capacities, short-time withstand current (Icw), and endurance under load conditions defined by utilization categories. For instance, short-time withstand tests evaluate the device's ability to carry a current for 1 second at levels such as 8 times the rated operational current (Ie) without exceeding temperature limits, confirming thermal resilience during faults. Mechanical endurance tests require devices to complete up to 10 million no-load operating cycles (per IEC 60947-4-1 for contactors), while electrical endurance tests involve category-specific sequences, such as for AC-3 operations simulating squirrel-cage motor starting with 7 starts per hour and a 30% . These sequences, detailed in IEC 60947-4-1, include operational cycles like open-close-open (O-CO) under rated conditions to measure durability, with at least 90% of samples meeting declared life spans. Compliance with IEC 60947 standards is demonstrated through third-party certifications and mandatory markings, ensuring devices meet safety and performance criteria for global markets. Certification bodies such as UL (Underwriters Laboratories) under UL 60947 series and VDE (Verband der Elektrotechnik) in verify adherence via factory audits and product evaluations, often aligning with the IECEE Scheme for international recognition. Marking requirements include the utilization category (e.g., "AC-3"), rated voltage (e.g., "400V"), and current (e.g., "50A"), along with the CE mark for conformity and manufacturer details, as stipulated in IEC 60947-1. Manufacturing audits by notified bodies, such as those under the for hazardous environments, monitor quality assurance processes to prevent deviations from standard specifications. Safety considerations in utilization categories focus on mitigating risks from mismatched applications, such as contact welding or arcing in overload scenarios, by ensuring devices are validated for specific load types and duty cycles. Proper adherence to IEC 60947 testing reduces fault propagation, with features like mirror contacts providing reliable auxiliary circuit isolation to avoid unintended operations. In machinery applications, these categories integrate into risk assessments per IEC 60204-1, which mandates evaluation of electrical equipment for hazards like electric shock and fire, incorporating utilization category matching to achieve required safety performance levels. Recent updates in the 2020s, including IEC 60947-1:2020, include improvements in DC testing and EMC requirements for low-voltage switchgear.
Test TypeKey RequirementsExample Metrics
Routine Tests, functional checksApplied to 100% of production units per IEC 60947-1
Type Tests: Short-Time WithstandThermal endurance at fault currents1 s at ≥8 × Ie; Icw ≥12 × In for breakers ≤2500 A per IEC 60947-2
Endurance TestsMechanical and electrical cycles10 million mechanical operations; category-specific sequences (e.g., AC-3: O-CO at 10 × Ie make/1 × Ie break) per IEC 60947-4-1

Comparative Analysis

Summary Table of Categories

The following table provides a consolidated overview of the major IEC utilization categories for low-voltage and controlgear, facilitating quick comparison across and types. Categories are drawn from relevant parts of the IEC 60947 series, with brief descriptors focused on load types and applications. Key characteristics include representative inrush factors (multiples of rated current Ie) and typical operating cycles (electrical life under rated conditions), where applicable for context on duty severity. Suffixes A/B denote frequent (A) or infrequent (B) operations; higher categories often require for inductive loads.
CategoryLoad TypeTypical ApplicationsKey CharacteristicsStandard Reference
AC-1Non-inductive or slightly inductiveResistive furnaces, heatersInrush ~1× Ie, >1 million cyclesIEC 60947-4-1
AC-2Moderately inductive (slip-ring motors)Starting and switching off slip-ring induction motorsInrush ~2.5× Ie, ~600,000 cyclesIEC 60947-4-1
AC-3Highly inductive (squirrel-cage motors)Starting and switching off running squirrel-cage motorsInrush 6–8× Ie, ~1 million cyclesIEC 60947-4-1
AC-4Highly inductive (squirrel-cage motors with frequent reversals)Starting, inching, and plugging of squirrel-cage motorsInrush 8–10× Ie, ~300,000 cyclesIEC 60947-4-1
AC-5aCapacitive/inductive (lamp controls)Switching electric discharge lamp loads (e.g., fluorescent)Inrush ~3× Ie, ~600,000 cyclesIEC 60947-4-1
AC-5bResistive/filamentSwitching incandescent lamp loadsInrush 10–15× Ie, ~400,000 cyclesIEC 60947-4-1
AC-6aInductive (transformers)Switching unloaded transformersInrush ~12× Ie, ~300,000 cyclesIEC 60947-4-1
AC-6bCapacitive banksSwitching capacitor banksInrush up to 100× Ie, ~100,000 cyclesIEC 60947-4-1
AC-7aSlightly inductive (household)Household appliances with slightly inductive loads (<100 W)Inrush ~1× Ie, >1 million cyclesIEC 60947-4-1
AC-7bMotor loads (household)Small motor loads in household appliancesInrush 6–8× Ie, ~1 million cyclesIEC 60947-4-1
AC-8aCompressor motors (manual reset)Hermetic refrigerant compressor motors with manual overload resetInrush ~6× Ie, ~500,000 cyclesIEC 60947-4-1
AC-8bCompressor motors (auto reset)Hermetic refrigerant compressor motors with automatic overload resetInrush ~6× Ie, ~500,000 cyclesIEC 60947-4-1
AC-12Resistive/solid-stateControl of resistive loads and solid-state devices in control circuitsInrush ~1× Ie, >1 million cyclesIEC 60947-5-1
AC-14Low-power electromagneticControl of small AC electromagnets or solenoids (<1 VA)Inrush ~4–6× Ie, ~500,000 cyclesIEC 60947-5-1
AC-15Electromagnetic (>2 VA)Control of AC electromagnetic loads (e.g., relays, contactors)Inrush ~10× Ie, ~500,000 cyclesIEC 60947-5-1
AC-20A/BNo-loadConnecting/disconnecting under no-load conditionsNo inrush, mechanical life >10,000 operations (A/B)IEC 60947-3
AC-21A/BResistive, moderate overloadSwitching resistive loads (e.g., heaters) with low overloadInrush ~1.5× Ie, ~5,000–10,000 cycles (A/B)IEC 60947-3
AC-22A/BMixed resistive/inductive, moderate overloadSwitching mixed loads (e.g., small motors) with low overloadInrush ~3–4× Ie, ~3,000–6,000 cycles (A/B)IEC 60947-3
AC-23A/BHighly inductive/motorSwitching motor or highly inductive loadsInrush 6–8× Ie, ~2,000–4,000 cycles (A/B)IEC 60947-3
DC-1Non-inductive or slightly inductiveResistive loads, e.g., resistance furnacesInrush ~1× Ie, >1 million cycles; low arcIEC 60947-4-1
DC-3Inductive (shunt motors)Starting, plugging, inching, dynamic braking of shunt motorsInrush ~2.5× Ie, time constant 2.5 ms, ~600,000 cycles; arc blowout recommendedIEC 60947-4-1
DC-5Highly inductive (series motors or electromagnets)Starting, plugging, inching, dynamic braking of series motors; high inductive loads like electromagnetsInrush ~2.5× Ie, time constant 15 ms, ~600,000 cycles; arc blowout requiredIEC 60947-4-1
DC-6Resistive/filamentSwitching incandescent lampsInrush ~1× Ie, ~600,000 cycles; minimal arcingIEC 60947-4-1
DC-12Resistive/solid-stateControl of resistive loads and solid-state devices in control circuitsInrush ~1× Ie, >1 million cycles; low arcIEC 60947-5-1
DC-13ElectromagneticControl of DC electromagnetic loads (e.g., solenoids, brakes)Inrush ~5–10× Ie, ~300,000–500,000 cycles; arc suppression neededIEC 60947-5-1
Footnotes:
  1. Categories AC-20A/B and DC-20A/B are not permitted for use in the due to differing national standards.
  2. Symbols A/B distinguish operation frequency: A for ≥10 operations/hour or short intervals, B for <10 operations/hour or longer intervals.
  3. Inrush factors and cycles are representative for typical rated operational currents (up to 690 V); actual values depend on specific device ratings and test conditions per standard. Higher inductive loads in DC categories often necessitate magnetic blowout to extinguish arcs.

Variations Across Standards and Regions

Utilization categories for low-voltage and controlgear, as defined in the IEC 60947 series, differ significantly from those in the NEMA standards prevalent . While IEC categories such as AC-1 through AC-4 emphasize specific load types, operational cycles, and performance endurance (e.g., mechanical and electrical life cycles for contactors), NEMA standards for contactors and starters use size designations like 00 through 5 for smaller devices, focusing instead on horsepower ratings and sizes for interchangeability and robustness in applications. NEMA lacks direct equivalents to IEC's AC/DC utilization categories, prioritizing overload capacity (up to 25% service factor) and types (e.g., NEMA 1 for indoor or NEMA 4X for corrosion resistance) over cycle-based performance metrics. In , the EN 60947 series directly mirrors the IEC 60947 standards, serving as harmonized European norms that adopt IEC requirements without substantial deviations for utilization categories in contactors and switches. However, in , UL 508 for industrial control equipment has been partially harmonized with IEC 60947 (e.g., UL 60947-4-1 for contactors), but incorporates additional safety factors such as enhanced short-circuit protection and restricts certain IEC categories like AC-20A/B, which involve no-load operations and are not permitted for use in the due to differing risk assessments. Regional adaptations further highlight variations; China's GB/T 14048 series closely aligns with IEC 60947, adopting similar utilization categories for contactors (e.g., GB/T 14048.4-1 equivalent to IEC 60947-4-1) to facilitate global manufacturing compatibility. In , the JIS C 8201 series corresponds to IEC 60947-1 for general rules but includes modifications for seismic resilience, requiring contactors and controlgear to withstand accelerations up to 1g or higher in high-risk zones, influencing mounting and designs beyond standard utilization performance. Key differences underscore regional priorities: IEC and aligned standards stress endurance through defined operational cycles (e.g., 1 million mechanical operations for AC-3 motor starting), whereas NEMA emphasizes enclosure integrity against environmental hazards. Emerging ISO standards for , such as those in ISO/TC 22/SC 37, introduce hybrid AC/DC categories tailored to EV , blending IEC-like utilization with vehicle-specific duty cycles for management and inverters. Post-2020 updates to IEC 60947-3 (edition 4.0, 2020-04, with AMD1:2025) added requirements for switches in photovoltaic () DC applications, such as critical load current tests and dedicated accessories for renewables, which remain unadopted in NEMA frameworks focused on traditional industrial loads.

References

  1. [1]
    [PDF] Load characteristics and utilization categories - Rockwell Automation
    Utilization categories simplify the selection of devices ... Utilization categories ...
  2. [2]
    Utilisation Categories - IEC Standards - Guides - Rowse
    Oct 17, 2019 · Utilization categories are defined in the standards for low-voltage switchgear low-voltage switchgear (IEC 60947-1, -2, -3, -4, -5, -6), they take into account ...
  3. [3]
    [PDF] IS/IEC 60947-1 (2007): Low-voltage switchgear and controlgear ...
    for different duties and utilization categories. NOTE 5. Attention is drawn to the fact that the operational voltage may differ from the working voltage. (see ...
  4. [4]
    What is the meaning of the utilisation categories AC1 and AC3 for ...
    Oct 20, 2010 · The standard utilisation categories defines the current making and breaking values for contactors. They depend on the following:Missing: importance | Show results with:importance
  5. [5]
    Electrical Standards for Contactors: Understanding AC1, AC2, AC3 ...
    Mar 9, 2025 · Utilization categories standardize the selection of contactors by correlating their design with the electrical characteristics of the load they ...
  6. [6]
    IEC 60947:2025 SER
    Jul 23, 2025 · IEC 60947:2025 SER is an international standard for low-voltage switchgear and controlgear, published on 2025-07-23, and includes a 15% ...
  7. [7]
    IEC 60947-1:2020
    Apr 22, 2020 · This document states the general rules and common safety requirements for low-voltage switchgear and controlgear.
  8. [8]
    IEC 60947-4-1:2023
    Nov 8, 2023 · IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and ...
  9. [9]
    [PDF] Development of LV circuit breakers to standard IEC 947-2
    The work of these international experts. (including three engineers from Schneider) resulted in the publication in 1989 of the first edition of standard IEC 947 ...<|control11|><|separator|>
  10. [10]
    UL 60947-1 | UL Standards & Engagement
    This standard states the general rules and common safety requirements for low-voltage switchgear and controlgear.
  11. [11]
    IEC 60947-4-1:1990
    This publication supersedes IEC 60158-1 (1970) and its Amendment 1 (1983), 60158-1C (1982), 60292-1 (1969) and its Amendment 2 (1983), 60292-2 (1970), 60292-3 ( ...
  12. [12]
    [PDF] The History of the VDE
    After the Second World War, the activities of the new 'VDE Testing and Certification Institute' 14 were started in 1948 in Wuppertal.Missing: switchgear | Show results with:switchgear
  13. [13]
    IEC 60947-4-1:2000
    This publication supersedes IEC 60158-1 (1970) and its Amendment 1 (1983), 60158-1C (1982), 60292-1 (1969) and its Amendment 2 (1983), 60292-2 (1970), 60292-3 ( ...
  14. [14]
    IEC 60947-4-1:2009/AMD1:2012
    Edition 5, 2023-11-08, IEC 60947-4-1:2023 ; Edition 4, 2021-04-20, IEC 60947-4-1:2018/COR2:2021 ; 2020-04-22, IEC 60947-4-1:2018/COR1:2020 ; 2020-03-13, IEC 60947- ...
  15. [15]
    Industrial Control Equipment Transition to IEC Standards
    Helping you transition to new standards for industrial control equipment that are being harmonized to increase global market access.
  16. [16]
    IEC 60947-4-1:2018 RLV - IEC Webstore
    Oct 25, 2018 · IEC 60947-4-1:2018 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching device (MPSD);
  17. [17]
    [PDF] 7767e TC 121_RSMB and SBP 2022-11 - IEC
    Nov 14, 2022 · The increased use of local, renewable generation of energy, energy storage and energy management ... - Future integration of new.
  18. [18]
  19. [19]
    IEC Load Utilization Categories - Specified Power Solutions
    IEC Utilization Categories ; AC 7b, Household motor loads, eg; Fan, Vaccume pump motor. Switchgear: Electromechanical contactors for household purpose, eg.
  20. [20]
    What is the meaning of the utilisation categories AC1 and AC3 for ...
    Oct 20, 2010 · The standard utilisation categories defines the current making and breaking values for contactors. They depend on the following:
  21. [21]
    [PDF] IS/IEC 60947-4-1 (2000): Low-Voltage Switchgear and Controlgear ...
    Types of utilization other than the utilization categories d.flned In t.ble 1. 5.7.2. Specific applications of instantaneous over-current relays or r.I. ...
  22. [22]
    [PDF] IS/IEC 60947-3 (1999): Lowpvoltage switchgear and controlgear ...
    " The use of these utilization categories is not permitted in the United States of America. Category AC-23 includes occasional switching of individual motors.<|separator|>
  23. [23]
    [PDF] IEC-60947-4-1-2023.pdf - iTeh Standards
    Table 9 – Operational current determination for utilization categories AC-6a and AC-6b ... Table M.7 – Number of operating cycles corresponding to the ...
  24. [24]
    [PDF] IS/IEC 60947-5-1 (2003): Low-Voltage Switchgear and Controlgear ...
    The utilization categories shall be AC-15 or DC-13. NOTE Additional utilization categories AC-14 and DC-14 are permitted. K.5. Product information. Clause 5 ...
  25. [25]
    [PDF] R.. Series Contactors - ABB
    A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated. ○ Utilization Categories for ...Missing: historical evolution
  26. [26]
    Overview of conventional utilization categories - ELESTA GmbH
    Overview of conventional utilization categories. Main circuits alternating current EN IEC 60947-4. Main circuits direct current EN IEC 60947-4.
  27. [27]
    [PDF] Brochure Contactors | Schaltbau - PPM Power
    Permanentmagnetic blowout and arc chamber for DC operation. Versatile series. Well-proven as line contactor, changeover unit and reverser. Suitable for use in ...
  28. [28]
    [PDF] Low Voltage Products Solutions for solar energy - ABB
    Under IEC 60947-3, Tmax PV offers switch-disconnectors to meet standard ... Molded case switch-disconnectors up to 1100V DC in compliance with IEC 60947-3.
  29. [29]
    [PDF] IEC Contactors and Starters | Eaton
    The XT line of IEC power control offers starting and protection solutions ideal for control panels. Innovations in the design and development allow users to.
  30. [30]
    What's the difference between NEMA and IEC motor starters?
    May 7, 2021 · NEMA and IEC motor starters differ in size, mounting, and rating. NEMA uses frame sizes, IEC uses utilization categories. NEMA is panel mounted ...
  31. [31]
    [PDF] NEMA Open Type Contactors and Starters - Literature Library
    NEMA size 00…5: factory assembled. NEMA size 0…5: factory assembled. Standards. • NEMA/EEMAC ICS2 (Industrial Controls and Systems). • UL 508. • CSA C22.2, No ...Missing: letters | Show results with:letters
  32. [32]
  33. [33]
    IEC vs. NEMA Motor Controls: Select the Best Option for Your ...
    NEMA uses frame sizes for interchangeability, while IEC uses utilization categories for space/cost savings. NEMA is more robust, IEC is smaller and cheaper.  ...
  34. [34]
    [PDF] Guide to Low Voltage Circuit-Breakers Standards - BEAMA
    To fully understand the scope of IEC 60947-2, one must refer back to the origins of circuit- breaker standards. The original standard in the UK was BS 3871 Part ...Missing: utilization | Show results with:utilization
  35. [35]
    [PDF] Transition to UL 60947-4-1A Frequently Asked Questions
    Feb 2, 2012 · Through our UL-Demko office we can provide a CB (Certified Body) certificate to several of the. IEC 60947 product standards. In addition, ...Missing: VDE | Show results with:VDE
  36. [36]
    [PDF] Utilization Categories
    * The application of these utilization categories isn't permitted in the USA. Category AC-23 includes occasional switching of individual motors. The ...
  37. [37]
    [PDF] Contactor manual - ABB
    DC-1, DC-3, DC-5, DC-PV3 applications according to IEC 60947-4-1. The circuit switching on DC is more difficult than on AC, as alternating current goes to zero ...Missing: bidirectional | Show results with:bidirectional<|separator|>
  38. [38]
  39. [39]
    43.120 - Electric road vehicles - ISO
    Exhaust emissions and fuel consumption measurements — Part 1: Non-externally chargeable vehicles. 90.60 · ISO/TC 22/SC 37 · ISO ...