Amsler grid

The Amsler grid is a simple, square-shaped diagnostic tool measuring 10 cm × 10 cm, consisting of evenly spaced horizontal and vertical lines forming small squares, with a central fixation dot, designed to detect distortions () or blind spots () in the central 20° of the (10° on each side of fixation). It was developed in 1947 by Marc Amsler (1891–1968), a ophthalmologist and student of Jules Gonin, building on earlier grid patterns by pioneers like Edmund Landolt to map macular function more precisely. Primarily used for monitoring macular and optic nerve disorders, the Amsler grid helps identify early signs of conditions such as wet age-related (wAMD), (CSCR), , cystoid , and even non-arteritic or pituitary tumors affecting the visual pathway. In patients with age-related (), it serves as a daily self-test to spot subtle vision changes, such as wavy or missing lines, that may signal progression from dry to wet , enabling prompt ophthalmologic intervention to preserve central vision. It is also employed in clinical settings as a screening tool before procedures like or for assessment, where it demonstrates moderate sensitivity (around 80%) and high specificity (over 95%) in detecting central field defects.

Fundamentals

Definition and Purpose

The Amsler grid is a simple diagnostic tool consisting of a square grid of evenly spaced horizontal and vertical lines, typically measuring 10 cm by 10 cm, with a central fixation point, designed for self-testing or clinical evaluation of the central 20 degrees of the . It features grid lines spaced at 5 mm intervals, forming 400 small squares, along with a central for fixation and an optional surrounding frame to delineate the test area. This configuration allows for the detection of subtle abnormalities in central vision when viewed at a standard distance of approximately 30 to 33 cm. The primary purpose of the Amsler grid is to identify early signs of macular dysfunction, including (perceived distortion of straight lines), scotomas (blind spots appearing as missing line segments), and or (illusions of objects appearing smaller or larger than actual size). It is particularly useful for monitoring conditions that affect the , such as age-related (AMD), by enabling patients to observe changes in their central over time. As a non-invasive, low-cost tool, the Amsler grid facilitates patient-administered monitoring at home, promoting early detection of visual changes without requiring specialized equipment or professional supervision for routine use. Developed in 1947 by Swiss ophthalmologist , it remains a cornerstone of outpatient visual assessment due to its accessibility and ease of implementation.

Historical Development

The Amsler grid was developed in the mid-1940s by Marc Amsler, a ophthalmologist (1891–1968) and professor at the , as a practical tool for assessing macular function. Amsler created it to overcome the shortcomings of traditional perimetry methods, which were cumbersome for detecting subtle central visual field defects like and scotomas associated with macular disorders. The grid's design drew inspiration from earlier subjective visual testing concepts, including a grid devised by French ophthalmologist Edmond Landolt in the late 19th century for evaluating visual acuity and field distortions. Amsler first detailed the tool in his 1947 publication "L'examen qualitatif de la fonction maculaire" in the journal Ophthalmologica, where he outlined its use for qualitative evaluation of the macula through patient-reported distortions on a simple lined chart. Following its European introduction, the Amsler grid saw rapid adoption in clinical settings during the late 1940s and 1950s, spreading to English-speaking countries through translations and ophthalmic publications that emphasized its utility for in macular disease patients. By the , it had achieved standardization as a core component of macular assessment protocols, with multiple variants emerging to accommodate different testing distances and conditions, and recommendations for routine home use in at-risk populations. The tool evolved from its initial paper-based form into a staple of ophthalmic practice, integrated into formal clinical guidelines by the 1980s, including those from the American Academy of Ophthalmology for age-related macular degeneration management. In the 1990s, refinements addressed limitations in color perception, leading to colored grid variants (such as blue-yellow designs) that improved detection sensitivity for patients with concurrent color vision deficiencies or specific macular pathologies.

Design and Variations

Core Design Elements

The Amsler grid consists of a square chart measuring 10 cm on each side, subdivided into a 20 by 20 array of smaller squares formed by horizontal and vertical lines spaced 5 mm apart. This configuration ensures that, when viewed at the standard distance, the entire grid subtends approximately 20 degrees of the central . At the core of the grid is a small black dot, typically 2-3 mm in diameter, serving as the fixation point for testing to focus attention on the macular region. Optimal viewing conditions are essential for accurate assessment, with the grid held at 30-33 cm from the eyes—equivalent to a typical reading distance—under normal room illumination without direct glare to avoid distortions from reflections. Patients should wear their corrective lenses for refractive errors during testing to ensure clear perception. These parameters standardize the test, allowing reliable detection of central visual anomalies. The design operates on principles of subjective perimetry, where the observer reports perceptions of the grid lines to identify deviations in the central visual field. The straight lines specifically probe for metamorphopsia or scotomas by assessing the integrity of straight-line perception, capitalizing on the macula's high visual acuity without relying on quantitative field measurements. Traditionally, the grid is printed on matte cardstock or heavy paper to minimize glare and reflections, with a standardized size promoting portability and consistent use in clinical or home settings.

Specific Chart Types

The Amsler grid encompasses several standardized chart variations, each tailored to highlight distinct aspects of central integrity while maintaining a consistent 10 cm × 10 cm size and 5 mm grid spacing for 1° at 33 cm viewing distance. These charts differ primarily in line color, background , and orientation to address specific patient needs in macular assessment. Chart 1 employs white lines on a black background, serving as the foundational type for broad central field evaluation due to its high contrast, which enhances visibility for patients with reduced acuity or low . This configuration minimizes environmental interference and facilitates detection of gross distortions or scotomas in routine screening. Chart 2 is similar to Chart 1 but includes additional diagonal white lines to aid fixation in patients with central scotomas. It helps maintain steady when the primary fixation point is obscured. Chart 3 features horizontal and vertical red lines on a black background, designed to isolate color alongside axial distortions by targeting long-wavelength function, making it valuable for detecting incipient changes in conditions like age-related (). The red hue aids in revealing desaturation or selective field losses not apparent in achromatic tests. Chart 4 consists of a black background with a central large white dot and scattered small white dots, without grid lines, to differentiate between scotomas and by assessing dot . This setup uncovers areas of visual loss without the influence of line distortions. Chart 5 incorporates only horizontal white lines spaced 5 mm apart on a black background, with a central white dot, concentrating on vertical field defects by emphasizing perpendicular distortions and facilitating meridian-specific analysis. This focused orientation helps delineate superior or inferior scotomas or waviness in targeted regions. Chart 6 is similar to Chart 5 but uses black lines on a white background, with lines closer together near the fixation point to detect fine . It provides higher contrast for certain patients and finer resolution centrally. Chart 7 is a modification of Chart 1 with the central 5 cm × 5 cm area divided into smaller squares subtending 0.5° of , allowing for more detailed of the paracentral . It complements standard grids by addressing subtle central anomalies. Selection of a specific chart depends on clinical context and patient profile; for instance, Chart 1 suits initial broad screening, while Charts 3 and 4 are preferred for cases involving potential impairments or differentiation of defects, such as in monitoring. Overall, these variations allow clinicians to customize testing to symptom patterns, enhancing diagnostic sensitivity without altering core procedural elements.

Administration and Interpretation

Testing Procedure

The Amsler grid test is administered monocularly to assess central integrity, beginning with proper preparation to ensure accurate results. Patients should first correct any refractive errors by wearing their usual reading glasses or contact lenses, if applicable. The grid is held at a of 30 to 33 centimeters (approximately 12 to 13 inches) from the eyes, positioned perpendicular to the to simulate normal reading conditions. Adequate but not overly bright lighting is used to illuminate the grid evenly, avoiding or direct light that could interfere with perception; for routine screening, the standard white grid with black lines and a central (Chart 1) is typically selected. Testing proceeds with one eye at a time to isolate potential abnormalities. The patient covers the non-testing eye completely, such as with an occluder or hand, and fixates steadily on the central dot of the without shifting or head position. While maintaining fixation, the patient examines the entire , reporting whether the lines appear straight and uniform or exhibit distortions such as waviness (), fading, blurring, or missing segments (scotomas). If distortions are noted, the patient may be instructed to mark them directly on a copy of the using a pen to indicate affected areas for later reference. This process is then repeated for the fellow eye. In a clinical setting, the ophthalmologist or supervises the test, observing for proper with instructions and providing neutral verbal prompts, such as reminding to focus solely on the center dot, without suggesting expected findings. The procedure typically takes 1 to 2 minutes per eye. For at-risk patients, such as those with age-related , self-monitoring with the Amsler grid is recommended weekly, though daily use may be advised in certain cases to detect subtle changes early.

Result Analysis

A normal response on the Amsler grid consists of all lines appearing straight, complete, and uniform, with no gaps, bends, or distortions when the patient fixates on the central dot. This indicates intact central integrity, particularly in the . Abnormal patterns reveal disruptions in the central . manifests as wavy or curved lines, suggesting retinal wrinkling or distortion, often due to macular involvement. Relative appears as faded or partially obscured lines, indicating partial vision loss where areas are dimly perceived. Absolute presents as completely missing lines or blank areas, denoting blind spots with no light perception in those regions. Documentation typically involves patients sketching or marking the perceived abnormalities directly on a copy of the grid, or capturing photos for serial comparison to track progression. Comparisons may include binocular versus testing to isolate unilateral issues. Relative defects are graded by the intensity of line perception, with faded areas suggesting lesser impairment than absolute ones, which show total absence. Any detected abnormality on the Amsler grid warrants immediate referral to an for confirmatory evaluation, often including (OCT) to assess retinal structure.

Clinical Applications

Primary Uses in

The Amsler grid plays a central role in the initial of macular disorders by revealing subjective visual distortions in the central . It is especially effective for detecting , where patients perceive straight lines as wavy or irregular, signaling early retinal changes that may not yet be evident on objective imaging. This tool aids in identifying symptomatic maculopathies during routine evaluations, allowing for prompt confirmation with advanced diagnostics like (OCT). In age-related macular degeneration (AMD), the Amsler grid detects early dry through metamorphopsia arising from accumulation and monitors progression to wet by highlighting new distortions or scotomas due to choroidal neovascular membranes. For diabetic , it identifies central visual distortions from retinal swelling, often presenting as where grid squares appear smaller as photoreceptor layers separate. In macular holes, the grid reveals scotomas corresponding to the central defect, while epiretinal membranes cause wavy lines from tangential traction on the ; central serous similarly shows or relative central scotomas from subretinal fluid. As a diagnostic adjunct, the Amsler grid complements fundus examinations by providing for patient-reported symptoms in maculopathies, with meta-analyses reporting approximately 67% for neovascular when benchmarked against clinical standards. It also supports by enabling self-monitoring of visual changes after treatments, such as injections for , to facilitate early detection of recurrence and timely follow-up care.

Monitoring and Screening

The Amsler grid plays a key role in tracking disease progression for patients with age-related (), enabling early detection of central changes that may signal worsening before symptoms become severe. For individuals diagnosed with , regular home use of the grid—often daily—is recommended to monitor for distortions or blind spots in the central , allowing timely intervention to prevent loss. Patients are instructed to test each eye separately while wearing reading glasses, focusing on the center dot, and to note any abnormalities for comparison over time. This self-monitoring approach is particularly valuable for those with intermediate or high-risk dry , where progression to wet can occur rapidly. In post-treatment follow-up for macular conditions, the Amsler grid facilitates routine checks after interventions such as laser therapy or injections for wet AMD. Patients are encouraged to continue grid testing between clinical visits to identify any recurrence of or scotomas, prompting immediate specialist consultation if changes appear. This ongoing surveillance helps assess treatment efficacy and detect complications early, with marked grids providing a simple record for ophthalmologists to evaluate stability or progression during follow-up appointments. Screening programs incorporating the Amsler grid target at-risk populations, such as adults over 50 or those with a family history of , in community and settings. Organizations like Prevent Blindness distribute free Amsler grids as part of awareness campaigns to promote self-screening, often integrated into annual comprehensive eye exams for early identification of macular issues. The grid's simplicity makes it suitable for broad use in these programs, where it serves as an initial tool to flag potential before referral for advanced imaging. Telemedicine has enhanced the grid's utility through digital adaptations, allowing patients to submit test results via mobile apps for remote review by specialists. This integration supports ongoing monitoring for patients in rural or mobility-limited areas, with apps enabling annotated grids to be shared securely during virtual consultations. Guidelines from authoritative bodies emphasize the Amsler grid's role in high-risk monitoring, with the National Eye Institute noting that eye care professionals may use the Amsler grid during dilated eye exams to assess central vision changes in patients, and frequency tailored to individual risk—such as more frequent home testing for advanced cases. The American Academy of Ophthalmology endorses daily self-testing for those with diagnosed to maximize early detection benefits.

Limitations and Modern Developments

Traditional Limitations

The traditional Amsler grid, as a subjective tool, relies heavily on patient-reported perceptions of visual distortions or scotomas, which introduces significant variability in results due to individual interpretation and execution. Studies have shown moderate to low test-retest reliability, with Pearson coefficients as low as 0.30 over intervals like 12 weeks, highlighting inconsistent across repeated administrations. This subjectivity is compounded by the test's qualitative nature, providing no objective quantification of distortion magnitude, such as degrees of , limiting its utility for precise monitoring. The grid's design restricts evaluation to the central 20 degrees of the when viewed at the standard 30 cm distance, rendering it insensitive to peripheral defects beyond this range. Validation studies, particularly from the 1990s and early 2000s, demonstrate low sensitivity for early or intermediate age-related (AMD), detecting abnormalities in only about 8% of early cases and 20% of intermediate cases compared to more comprehensive assessments. Meta-analyses confirm overall sensitivity around 67-78% for neovascular AMD, often missing subtle early changes and leading to delayed intervention. Patient compliance poses another challenge, especially among the elderly, with one reporting only 55% adherence to regular home monitoring over 12 months due to factors like forgetfulness or perceived burden. Results can also be influenced by external variables, including suboptimal lighting conditions that alter line visibility and , as well as fatigue or cognitive impairments that affect attention during testing. Early critiques from the 1950s through 1970s emphasized the grid's over-reliance without confirmatory methods like perimetry, noting its potential to overlook defects not captured in central testing alone.

Digital and Advanced Adaptations

Digital versions of the Amsler grid have emerged as applications since the , enabling patients to perform self-monitoring tests at home with enhanced interactivity. The Eyecare-Amsler Grid app, developed by Eyemaginations and available on since 2015, allows users to trace distortions on a touch-screen grid using their finger, facilitating daily detection of subtle vision changes associated with . Similarly, the PocDoc app, introduced in a 2024 validation study, incorporates a digital grid where users draw perceived distortions and scotomas, with built-in algorithms providing automated pattern analysis to quantify abnormalities more objectively than paper-based methods. These apps address traditional subjectivity by storing results over time for trend tracking and alerting users to changes requiring clinical review. Advancements in digital adaptations include integrations with for precise distortion quantification, particularly through models developed since 2020. The iterative Amsler Grid (IAG) procedure, validated in a 2022 study, uses computational mapping to generate quantifiable deformation maps from user inputs on a digital interface, improving measurement reliability for in age-related (). While direct AI applications to Amsler grids remain emerging, broader frameworks in home monitoring devices, such as those analyzing hyperacuity shifts, achieve sensitivities up to 92% for neovascular AMD detection when combined with data. Advanced clinical tools hybridize Amsler-like testing with microperimetry for superior accuracy. The microperimeter, a confocal scanning device, combines fundus with automated perimetric testing to assess macular , offering a dynamic range of up to 36 and retinal tracking that surpasses the qualitative limitations of traditional grids. A 2022 study comparing tablet-based digital monitoring to reported higher retinal measurements (29.1 vs. 27.1 ) with the digital tool, highlighting its role in precise progression tracking for intermediate . Virtual reality (VR) adaptations provide immersive environments for Amsler grid testing, enhancing patient engagement and test validity. In a 2022 non-inferiority trial using VIVE Pro and headsets, a VR Amsler analogue allowed free-drawing of distorted areas on a virtual grid, achieving 100% sensitivity and 95-98% specificity compared to standard Amsler tests, with significantly faster completion times. This approach simulates real-world viewing conditions, potentially improving detection of central field defects in macular diseases. Post-2020 research demonstrates improved diagnostic performance with Amsler adaptations, particularly in sensitivity for early changes. The PocDoc validation study reported enhanced quantification of distortions, enabling better mapping than conventional grids. During the , teleophthalmology platforms integrated these apps for remote monitoring; for instance, Singapore's 2020 lockdown trials using devices like Alleye (a hyperacuity akin to advanced Amsler) maintained follow-up with 86% satisfaction and reduced in-person visits. Overall, versions show sensitivities up to 100% in controlled settings, contrasting traditional grids' lower rates. Future directions include wearable integrations for continuous Amsler-based monitoring, such as head-mounted devices like the NGRID system, which performs exams in under 10 minutes via portable diagnostics. Predictive analytics may further evolve by leveraging on longitudinal digital Amsler data alongside imaging, as explored in 2022 models for AMD progression forecasting, potentially enabling earlier interventions for at-risk patients.

References

  1. [1]
    Amsler Grid - StatPearls - NCBI Bookshelf
    Aug 25, 2023 · The grid gets its name from Marc Amsler (1891-1968), a Swiss ophthalmologist, who described the chart in 1947.[1] He was a student of Jules ...
  2. [2]
    Amsler Grid Eye Test: What It Is, Types & Uses - Cleveland Clinic
    Nov 3, 2023 · The Amsler grid eye test helps you see vision distortions (metamorphopsia) that can happen if you have certain conditions affecting your macula.
  3. [3]
    All Squared Away - Review of Optometry
    Mar 15, 2022 · Named after Marc Amsler, a Swiss ophthalmologist active in the 1940s, the Amsler grid is a 10cm-by-10cm box that contains a series of smaller ...<|control11|><|separator|>
  4. [4]
    Have AMD? Save Your Sight with an Amsler Grid
    May 3, 2023 · The Amsler grid is a simple square containing a grid pattern and a dot in the middle. When used correctly—once a day, every day—the Amsler grid ...
  5. [5]
    Home vision monitoring in patients with maculopathy
    Mar 27, 2023 · The grid is a 10 × 10 cm chart with 400 single squares, each representing an angle of 1°. Patients are required to fixate on a central dot and ...
  6. [6]
    Amsler Grid Testing - EyeRounds
    Jan 9, 2017 · Amsler grid testing examines the central 20 degrees of the visual field. The patient is instructed to look at the black dot in the center of the grid.
  7. [7]
    Tests for Potential Vision - StatPearls - NCBI - NIH
    Mar 26, 2023 · [13] It is a grid of horizontal and vertical lines that monitors a person's central 20 degrees of the visual field. It can be an alternative to ...
  8. [8]
    21 CFR Part 886 Subpart B -- Diagnostic Devices - eCFR
    § 886.1330 Amsler grid.​​ (a) Identification. An Amsler grid is a device that is a series of charts with grids of different sizes that are held at 30 centimeters ...
  9. [9]
    Using the Amsler Grid Test for Age-Related Macular Degeneration ...
    Feb 22, 2024 · The test is an inexpensive, self-administered, practical method for detecting signs of macular disease and monitoring its progression.Missing: definition dysfunction
  10. [10]
    Macular Degeneration | AOA - American Optometric Association
    A doctor of optometry can also provide a simple take-home screening test called an AmsLer Grid. Central vision that is lost to macular degeneration cannot be ...
  11. [11]
    Macular function surveillance revisited - PubMed
    Background: The Amsler grid is a widely used means of evaluating the central 20 degrees diameter visual field. It is a common practice to have patients who ...
  12. [12]
    Contributions to Progress in Ophthalmology from Switzerland
    The Amsler grid which many patients suffering from AMD worldwide are using for self-testing their own central visual field was designed by Marc Amsler (1891– ...
  13. [13]
    Amsler Grid: Eye Tests and Charts - WebMD
    Aug 17, 2024 · He was a Swiss ophthalmologist, or eye doctor, who described the tool in 1947. A basic Amsler grid is a 10x10-centimeter square filled with ...Missing: invention | Show results with:invention
  14. [14]
    The Amsler chart: absence of evidence is not ... - PubMed Central
    The Amsler charts, first described in 1947 by the Swiss ophthalmologist Marc Amsler, are thought to have been inspired by a grid designed by Landolt. A similar ...
  15. [15]
    A brief history of macular grids: from Thomas Reid to Edvard Munch ...
    Lines or grids to document metamorphopsia have appeared in ophthalmology textbooks for more than 100 years, but testing for macular degeneration did not become ...Missing: Salzmann | Show results with:Salzmann
  16. [16]
    Diagnostic Accuracy of the Amsler Grid Test for Detecting ...
    Feb 16, 2023 · Health professionals often recommend the Amsler grid, which was first described and popularized by the Swiss ophthalmologist Marc Amsler in the ...
  17. [17]
    Diagnostic accuracy of the Amsler grid and the preferential ... - Nature
    May 2, 2014 · The Amsler grid test has been around and in use for over 60 years. From the time of Amsler's publication in 1947 until the late 1990s, its ...
  18. [18]
    Amsler Grid - an overview | ScienceDirect Topics
    The Amsler grid, a ubiquitous feature of ophthalmic offices and in the homes of macular degeneration patients, dates back to 1947 and is named after the Swiss ...Missing: invention | Show results with:invention
  19. [19]
    Evaluation of a Digital Amsler Grid (PocDoc) for Macular Disease ...
    Mar 20, 2024 · This study introduces PocDoc, a digital version of the conventional Amsler grid, aimed at enhancing the screening and monitoring of macular diseases.Missing: dysfunction | Show results with:dysfunction
  20. [20]
    How to Use the Amsler Grid to Test Your Vision - Healthline
    Jan 27, 2023 · The Amsler grid looks best on pure white matte paper. You can get your own copy to print off here. Your eye care professional may also be able ...
  21. [21]
    Visual Field Tests: A Narrative Review of Different Perimetric Methods
    Apr 23, 2024 · Another qualitative VF method is the Amsler Grid. It is a basic test for the central VF, performed by placing a printed grid at a reading ...
  22. [22]
  23. [23]
    The Amsler Grid: White on Black or Black on White? - IOVS
    Abstract: : Purpose: To compare the original Amsler grid with white lines on black background developed by Mark Amsler in 1947, exemplified by the Yannuzzi ...
  24. [24]
    Amsler Grid Eye Test - BrightFocus Foundation
    Feb 8, 2024 · The Amsler grid is an at-home eye test that can help detect early signs of retinal disease such as age-related macular degeneration (AMD). If ...
  25. [25]
    Timing the Retinal Referral: Tips for Success - Review of Optometry
    Jun 15, 2023 · Close follow-up including monitoring of VA, amsler grid and OCT can aid in assessing the staging of the condition. Proper protocol and ...
  26. [26]
    Dry macular degeneration - Diagnosis and treatment - Mayo Clinic
    Ask your eye doctor about the recommended schedule for follow-up exams. In between checkups, you can do a self-assessment of your vision using an Amsler grid.Care at Mayo Clinic · Symptoms and causes · Bionic eye offers hope of...Missing: post- | Show results with:post-
  27. [27]
    Free Resources for AMD, Low Vision - Prevent Blindness
    Jan 22, 2014 · AMD Awareness Makes a Difference– Through its annual campaign, Prevent Blindness offers a free magnetic Amsler grid. An Amsler grid is a grid of ...
  28. [28]
    Amsler Grid Test: Screening for AMD - Optometrists.org
    Hold the Amsler grid at a distance that enables all grid lines to be in-focus, approximately 14 to 16 inches from your face. Test each eye separately, covering ...Early Detection Of Eye... · Guide To Macular... · How Does The Amsler Grid...
  29. [29]
    [PDF] Age-Related Macular Degeneration What You Should Know
    Your eye care professional also may ask you to look at an Amsler grid. Changes in your central vision may cause the lines in the grid to disappear or appear.
  30. [30]
    Multi-line Adaptive Perimetry (MAP): A New Procedure for ...
    We evaluated test–retest reliability of MAP, MAIA, and Amsler grid visual field patterns using two complementary techniques. We evaluated Pearson product–moment ...
  31. [31]
    Amsler Chart - an overview | ScienceDirect Topics
    Amsler charts are used to measure the central 10° visual field and provide quick, portable assessments for home monitoring, though they rely on subjective ...Missing: 1990s blindness
  32. [32]
    The Amsler chart is of doubtful value in retinal screening for early ...
    May 7, 2004 · Specific instructions were given on how to use the chart at the time of its dispensation: 'Hold the chart before yourself at 30 centimetres, ...
  33. [33]
    results of a multicenter clinical trial to evaluate the preferential...
    Of 20 eyes with intermediate AMD, 14 (70%) were positive on the PHP, and 4 (20%), on the Amsler grid. Of 51 eyes with early AMD, 21 (41%) were positive on the ...
  34. [34]
    Diagnostic accuracy of the Amsler grid and the preferential ... - NIH
    May 2, 2014 · Results from small preliminary studies show promising test performance characteristics both for the Amsler grid and PHP to rule out wet AMD in the screening ...Results · Test Performance · Study Selection
  35. [35]
    The Short-Term Compliance and Concordance to in Clinic Testing ...
    Compliance with regular home monitoring of vision with the Amsler grid is also poor and has been reported by 1 study to be 55% over a 12-month period. There are ...
  36. [36]
    Monitoring Your Vision: How the Amsler Grid Vision Test Gives ...
    Apr 25, 2024 · Ensure you have adequate lighting; dim lighting can affect the test's accuracy. Wear any glasses you typically wear to read. Sit or stand ...Missing: fatigue cognitive<|control11|><|separator|>