Cold finger

A cold finger is a specialized piece of designed to create a localized surface for condensing vapors or trapping volatile substances during chemical processes such as , , or . It typically features a finger-shaped tube, often made of , through which a —such as circulating , , or a dry ice-acetone slurry—is passed to achieve low temperatures, sometimes as low as -78°C, enabling efficient of gases into liquids that drip back into the reaction vessel. This apparatus functions on the principle of and , where heated vapors contact the cooled surface, lose heat, and revert to liquid form, thereby minimizing the escape of volatile materials and maintaining a in procedures like acid or rotary . Common variations include straight, coiled, or spiral designs to enhance surface area for , with standard joints for compatibility with other lab equipment like reaction flasks or digester tubes. In and analytical applications, cold fingers are essential for preventing loss, improving yield in reactions, and facilitating the recovery of solvents or products in distillations.

Design and construction

Core components

The core of a cold finger apparatus is a finger-like tube or probe that serves as the primary cold surface for condensing vapors or cooling substances within a reaction vessel or vacuum chamber. This central component is typically constructed from borosilicate glass or stainless steel, with dimensions ranging from 5 to 20 cm in length and 1 to 5 cm in diameter, allowing it to be inserted directly into flasks, condensers, or chambers for targeted cooling. For coolant circulation, the apparatus features and outlet ports, usually serrated barbs accommodating 8-10 mm tubing, positioned at the top and middle or bottom of the finger to facilitate the flow of refrigerants through an internal jacket or chamber. In designs employing static coolants, such as pellets, the finger incorporates a sealed internal chamber or side port for loading the material without continuous flow, enabling prolonged low-temperature maintenance. Mounting mechanisms ensure secure attachment to , commonly utilizing standard taper joints (e.g., 14/20 or 24/40 sizes) for airtight connections to round-bottom flasks or setups, or seals for vacuum-compatible assemblies that prevent leaks under reduced pressure. To minimize ambient heat gain and enhance efficiency, cold fingers often integrate with elements, such as external wraps, foam sheaths, or enclosing flasks, which isolate the cooled surface while allowing modular assembly for various experimental configurations. This supports applications like setups, where the isolated cold probe efficiently traps volatile compounds.

Materials and fabrication

Borosilicate glass is the primary material for laboratory cold fingers, valued for its high transparency, chemical inertness, and resistance to , which allows observation of processes while maintaining compatibility with various solvents and . In contrast, industrial and vacuum-compatible cold fingers often employ , such as grades 304 or 316L, for enhanced mechanical durability and corrosion resistance in harsh environments. is also utilized in vacuum systems due to its superior thermal conductivity, facilitating efficient in cryogenic applications. Fabrication of glass cold fingers relies on scientific techniques, where skilled artisans shape borosilicate tubing into precise forms, including joints and drip tips, to ensure vacuum-tight and custom fit for setups. For metal variants, precision machining processes are employed to mill or into the required , enabling tight tolerances and integration with coolant channels. In contemporary prototyping, additive manufacturing methods like of metal alloys are emerging for rapid iteration of complex designs, though traditional machining remains dominant for production units. A key design consideration in cold finger construction involves mitigating thermal expansion mismatches between dissimilar materials, such as glass and metal interfaces, to prevent cracking or during repeated cooling and heating cycles. Materials are selected or joined using techniques like compliant adhesives or graded interlayers to accommodate differential expansion coefficients, ensuring long-term structural integrity under cryogenic conditions. Cost and availability influence material choices; cold fingers typically range from $50 to $200, offering affordability for routine lab use, while or models cost $200 to $1000 due to higher material expenses and fabrication complexity.

Coolant systems

Cold fingers rely on various coolant systems to achieve and sustain the low temperatures necessary for effective and trapping of vapors. Static coolants, which do not require active circulation, are commonly employed for their simplicity in laboratory settings. , or solid at -78°C, is frequently used in a with solvents such as isopropanol or to enhance thermal contact and maintain uniform cooling; this mixture is recommended for most trap applications due to its safety and efficacy in condensing common organic vapors without the hazards associated with deeper cryogens. , boiling at -196°C, serves as a static coolant for demanding low-temperature needs, such as trapping highly volatile substances, though its use is cautioned against in open systems owing to risks of oxygen leading to mixtures. For less extreme cooling around 0°C, ice-water or ice-salt baths provide a milder static option, suitable for applications where minimal temperature depression suffices. Circulating coolant systems offer greater control and longevity for prolonged operations, recirculating a through the cold finger via integrated channels or external loops. Chilled systems, typically maintaining 5-15°C, utilize compact recirculating chillers to deliver consistent cooling without frequent manual intervention, making them ideal for routine or setups. Antifreeze mixtures, such as and blends, enable circulating systems to reach down to -40°C, providing a safer alternative to cryogenic fluids for mid-range in insulated cold fingers. Coolant delivery methods vary by system type to ensure efficient heat exchange. In static setups, gravity-fed reservoirs or flasks allow for simple immersion of the cold finger, with added incrementally to the solvent bath to prevent foaming and maintain levels during extended runs exceeding 30 minutes. Circulating systems employ peristaltic or mechanical pumps to propel the coolant through tubing connected to the finger's , enabling closed-loop operation that minimizes losses. Immersion in external baths, such as a shared , is another common approach, where the cold finger is partially submerged for indirect cooling, often used in multi-station configurations. Efficiency in coolant systems is influenced by insulation quality and heat load, with typical volumes ranging from 500 mL to 2 L for standard laboratory cold fingers to accommodate operational durations without overflow. Refill intervals for static coolants like slurries or depend on ; well-insulated setups may require replenishment every few hours to days, while circulating systems extend intervals to days or weeks by recycling the and monitoring levels periodically to avoid unexpected overflow from gas ingress.

Principle of operation

Cooling mechanisms

Cold fingers primarily generate and sustain cold surfaces through phase change and convective mechanisms, enabling precise in and settings. Phase change cooling relies on the absorbed during or , providing efficient, localized cooling without mechanical circulation. This approach is particularly suited for cryogenic applications where rapid heat removal is essential. In sublimation-based phase change cooling, the cold finger is filled with immersed in a like acetone, where the solid transitions directly to gas, absorbing significant and maintaining surface temperatures around -78°C. This process ensures uniform cooling along the finger's length, with the enhancing and preventing direct buildup on the surface. Evaporation-based cooling uses , which boils upon contact with the cold finger, initially forming a vapor layer that insulates until breakthrough allows direct immersion, achieving temperatures as low as -196°C through ongoing . These methods deliver rapid cooling rates, often reaching equilibrium within 5-15 minutes depending on the system's and initial conditions. Convective cooling, in contrast, employs forced circulation of chilled fluids through internal channels within the cold finger, such as double-walled tubes, to continuously transfer from the surface to an external or . This supports higher temperature ranges, typically from near 0°C up to 20°C, and allows for adjustable rates to match varying loads, integrating seamlessly with the device's components for stable operation. These insulation strategies ensure that surface temperatures remain within the targeted range of -196°C to 20°C, with minimal deviation over operational periods.

Heat transfer principles

The heat transfer in a cold finger is dominated by conduction through the solid material of the device, enabling efficient removal of latent heat from condensing vapors. This process is governed by Fourier's law, which states that the heat flux q is proportional to the negative temperature gradient: q = -k \nabla T where k is the thermal conductivity of the finger material (e.g., ~1 W/m·K for borosilicate glass), and \nabla T represents the spatial variation in temperature. High conduction efficiency is achieved due to the thin walls of the glass, minimizing thermal resistance and promoting quick cooling of the interface despite the low k. Condensation on the cold finger surface involves vapor molecules impinging on the chilled area, where they rapidly lose due to the low temperature, transitioning to liquid or solid phases and releasing . The rate of this is proportional to the temperature difference \Delta T between the incoming vapor and the surface, as greater \Delta T enhances the driving force for mass and , accelerating deposit formation. This dynamic is particularly effective in controlled environments, where sustained low surface temperatures (often below 0°C) facilitate efficient phase change without excessive . Compared to ambient , cold fingers provide significantly faster rates owing to the large \Delta T gradients achievable (e.g., 100-200°C between hot vapors and the cooled surface), which amplify and speed far beyond natural in air. These gradients are maintained by circulation at the finger's base, enabling targeted cooling that ambient methods cannot match. A key limitation arises from frost or ice buildup on the condensing surface during prolonged operation, which insulates the area and reduces effective surface area for , thereby diminishing efficiency over time and requiring periodic defrosting to restore performance.

Applications

Laboratory uses in chemistry

In chemistry, cold fingers serve as essential components in sublimation apparatus, where they are positioned above solid samples to condense and collect purified vapors. This exploits the direct of a solid to gas and back, enabling the isolation of volatile compounds from non-volatile impurities. For instance, extracted from tea leaves can be purified by heating the crude sample in a sublimation flask under reduced pressure, with the cold finger cooled by or dry -acetone mixture to deposit pure crystals on its surface. Similarly, iodine is commonly purified via , where gentle heating causes the solid to vaporize, and the cold finger facilitates the formation of shiny, needle-like crystals, leaving behind residues like salts or oxides. Cold fingers also function as efficient reflux condensers in , recirculating solvent vapors back into the reaction mixture to minimize loss and maintain constant volume. This is particularly useful in prolonged reactions requiring high temperatures, such as esterifications or amidations. In azeotropic distillations like the Dean-Stark method for removal during reactions, a cold finger can be integrated atop the apparatus to enhance vapor , ensuring efficient without excessive solvent evaporation. Integration of cold fingers with rotary evaporators improves the of low-boiling solvents, such as or , by providing a colder surface than standard water-cooled coils. Typically charged with and acetone to reach temperatures below -70°C, the cold finger traps vapors more effectively under , enhancing efficiency compared to conventional setups. A typical for using a cold finger in involves assembling the apparatus with a containing 0.5-2 g of sample, greasing for an airtight seal, and attaching the cold finger via a ground-glass . The flask is then heated gently (e.g., 50-100°C) under (10-50 mbar), while the cold finger is loaded with —such as ice water for moderate cooling or slurry for lower temperatures—and monitored for 1-4 hours until completes, with periodic checks for crystal formation and pressure stability.

Industrial and vacuum applications

In industrial vacuum systems, cold fingers serve as essential cold traps to prevent oil backstreaming from diffusion pumps, where vapors from the pump oil can migrate into the main chamber and contaminate processes requiring . Cooled typically with to temperatures around -170°C, these devices condense hydrocarbons and other condensable vapors, enabling system pressures below 10^{-7} and protecting sensitive equipment in applications like particle accelerators and surface analysis. For instance, in diffusion setups, the cold finger is positioned at the inlet, capturing molecules before they reach the high- environment, thus maintaining operational integrity and extending life without the need for frequent changes. This is particularly critical in large-scale systems where backstreaming can degrade vacuum levels from 10^{-6} to higher, compromising process yields. In , cold fingers are integrated into setups to recover purified product from solution, such as in falling film crystallizers. For active pharmaceutical ingredients () like ibuprofen, they facilitate impurity removal by allowing crystals to form on the cold surface while impurities remain in the mother liquor, achieving high purities in continuous processes. In fabrication, cold fingers can influence temperature profiles in (CVD) chambers through effects like cooling from process gases, which impacts epitaxial silicon growth for solar cells or integrated circuits. For example, in rapid thermal CVD reactors, managing such thermal effects stabilizes growth rates up to 10 μm/min at 1170°C and , supporting high-throughput production of layers with efficiencies up to 13.1%. Industrial cold fingers are scaled for demanding environments, often using modular or glass designs to accommodate larger vapor volumes in continuous operations while maintaining efficient .

Specialized variants

Dewar-style cold fingers incorporate double-walled insulation, similar to a flask, to minimize heat ingress and sustain low temperatures over extended periods without frequent coolant refills. This design typically features an inner cold finger immersed in a cryogenic fluid such as or dry ice-acetone mixtures, surrounded by an evacuated outer jacket that reduces and losses. Such construction enables operation at temperatures as low as -196°C for several hours, making them suitable for applications requiring stable, unattended cooling in systems. All-metal cold fingers, often fabricated from welded , provide enhanced durability and compatibility with cryogenic fluids in harsh or corrosive settings where components might degrade or shatter. These variants eliminate organic materials to prevent or chemical reactions, ensuring integrity and resistance to aggressive vapors or solvents. For instance, models with integrated flasks can achieve cryogenic temperatures while withstanding exposure to corrosive gases, supporting long-term use in industrial processes. Microfluidic cold fingers represent miniaturized adaptations, typically on the millimeter scale, integrated into devices for precise temperature control in workflows. These systems embed a metallic cold finger, such as , directly within microfluidic channels to create localized temperature gradients, enabling studies like the investigation of ice-binding proteins by freezing specific regions without affecting the entire chip. Fabricated using techniques like or , they facilitate rapid cooling rates and down to micrometers, ideal for high-throughput biochemical assays. Hybrid cold finger systems combine traditional cryogenic or evaporative cooling with Peltier thermoelectric modules for electricity-driven, vibration-free temperature regulation, typically achieving ranges from 0°C to -50°C with fine control. In these setups, the Peltier element attaches to the cold finger base, transferring electronically while a secondary manages the hot side, as seen in space-grade thermal control for detectors. This integration allows programmable cooling profiles without mechanical compressors, enhancing portability and precision in sensitive optical or applications.

History and development

Origins and invention

The , a specialized designed to provide a localized cooled surface for vapor , emerged in the early as an adaptation of earlier straight-tube condensers like the Liebig model, which had been in use since the for basic tasks. This evolution addressed the growing need for precise control over volatile vapors in , particularly as techniques gained prominence for handling heat-sensitive compounds at reduced pressures. Chemists sought compact, efficient cooling to prevent loss of material during and low-boiling distillations, building on foundational work in from the . The specific design of the cold finger is credited to German chemist Paul Friedrichs, who introduced it in as part of innovative apparatus for enhanced and efficiency. In his seminal publication, Friedrichs described a finger-shaped inner tube, often spiraled for increased surface area, through which circulates to rapidly condense vapors rising from a reaction vessel below. This configuration allowed for superior compared to traditional water-jacketed tubes, minimizing flooding and enabling reliable operation under vacuum conditions typical of early 20th-century organic labs. The invention was motivated by the demands of emerging methods, which required better vapor containment to isolate pure sublimates without contamination. Following its introduction, the cold finger became a standard tool in laboratories for purifying volatile solids, as evidenced in mid-20th-century textbooks and procedural manuals that documented its use in experiments for compounds like derivatives. No specific U.S. for the basic cold finger design from the has been identified, suggesting it proliferated as unpatented standard glassware due to its simplicity and rapid adoption among chemists. This early integration marked the cold finger's role as an essential accessory for precise vapor management during the expansion of synthetic organic research.

Evolution and modern adaptations

Following , cold finger technology saw significant integration into laboratory workflows during the 1950s and 1960s, particularly through its incorporation into rotary evaporators developed by Büchi Labortechnik AG. The company's introduction of the Rotavapor in 1957 marked a pivotal advancement, as the device utilized cold finger condensers to efficiently capture vapors during , facilitating widespread adoption in labs for solvent recovery and purification processes. This synergy enhanced the precision and speed of techniques, transforming cold fingers from standalone tools into essential components of automated systems by the 1970s. A key milestone in formalizing cold finger designs occurred in 1960 with Kenneth B. Wiberg's textbook Laboratory Technique in , which detailed optimized configurations for and , emphasizing material choices and cooling efficiency to minimize contamination and maximize yield in synthetic procedures. From the 1980s onward, advancements shifted toward cryogenic coolants like for achieving sub-zero temperatures below -100°C, improving performance in vacuum applications and sensitive pharmaceutical syntheses. Concurrently, emerged in pharmaceutical labs, with computer-controlled circulation systems enabling precise temperature regulation and remote monitoring of coolant flow, reducing manual intervention and enhancing . In the , innovations have focused on and . A notable 2016 milestone is James W. Zubrick's The Organic Chem Lab Survival Manual (10th edition), which integrates protocols for cold fingers, including warnings on prevention and contamination avoidance during coolant changes.

Safety and maintenance

Potential hazards

One primary hazard associated with cold fingers is the risk of cryogenic burns from direct contact with the device's cooled surfaces, which can reach temperatures as low as -78°C when using as a . These burns occur rapidly due to the extreme cold causing tissue freezing and damage, similar to , and can affect any exposed or unprotected areas during handling or maintenance. Pressure buildup represents another significant risk, particularly when is employed as the cooling agent in confined spaces within the cold finger assembly. As sublimes directly to gas, it expands in volume by approximately 850 times, potentially generating excessive internal pressure that could shatter glass components if venting is inadequate. Chemical exposure hazards arise from the condensation of toxic vapors onto the cold finger, where solvents, acids, or other volatile substances from the process stream accumulate as liquids or solids. These condensates can pose risks of irritation, toxicity, or systemic effects if disturbed during operation or disassembly, especially with hazardous materials like chlorinated solvents or corrosive acids. In multi-use setups, risks emerge from residual chemicals adhering to the cold finger surfaces between experiments, leading to potential or adulteration of subsequent samples. Without thorough removal of prior condensates, trace impurities can transfer, compromising analytical purity or reaction outcomes in sensitive chemical procedures.

Operational best practices

Before operating a cold finger, inspect the glassware thoroughly for cracks, , nicks, or other defects, as damaged components can lead to under or . Always wear appropriate PPE, including cryogenic or insulated gloves and safety goggles, when handling the cold finger or adding . Ensure all joints are secure, properly lubricated if necessary, and free from strain to prevent leaks or breakage during assembly. For cold fingers using circulating systems, calibrate the flow rate per manufacturer guidelines to achieve uniform cooling and avoid inefficient operation or overheating. During use, initiate cooling gradually by adding or coolant slowly to the bath—such as or acetone—to prevent to the glassware or excessive foaming. Monitor the cold finger regularly for frost buildup or , which can block vapor flow or reduce efficiency; perform checks every 30 minutes in prolonged operations, particularly in vacuum setups, and clear any accumulation promptly. After use, clean glass cold fingers by rinsing with warm to remove residues, followed by a wash if needed, and dry thoroughly to prevent in subsequent runs. For stubborn residues, employ ultrasonic with appropriate solvents, ensuring all parts are disassembled first. Store cleaned cold fingers in a dry, dust-free environment to maintain integrity and avoid moisture-related damage. For disposal of spent cryogens like (solid CO2), allow in a well-ventilated area such as a or outdoors to prevent asphyxiation from CO2 buildup, following institutional lab regulations; never dispose of in sinks or drains, as extreme cold can damage .

References

  1. [1]
    Cold Finger Condensers | Fisher Scientific
    Cold finger condensers are a type of cold trap that generates a localized cold surface for the purposes of sublimation or for reflux and distillation ...
  2. [2]
    What Is A Cold Finger Condenser? - News - Achieve Chem
    Feb 23, 2024 · Cold finger condensers, comprising a tube immersed in a cooling medium, function based on the principle of condensation. As vapor passes ...
  3. [3]
    A review of reflux systems using cold finger for sample preparation ...
    Fundamental principles of cold finger. The “cold finger” is a glass tube in the shape of finger that is placed over the digester tube during procedures of acid ...
  4. [4]
    Distillation and Reflux Condensers - Lab-Training.com
    Coolant is made to flow through the internal cold finger and vapours rise along the spiral path. Such condensers are suitable for both distillations and reflux ...
  5. [5]
    CONDENSERS, MICRO COLD FINGER**- Chemglass Life Sciences
    Cold finger extends either 5mm or 13mm below the joint and is used on a flask with the listed joint size. Hose connection is 10mm at the largest serration. ** ...
  6. [6]
    Condenser, Cold Finger - Prism Research Glass
    In stockIt can typically handle temperature ranges between -80°C (-112°F) and 500°C (930°F) without cracking and typically has a melting point of around 1650° ...Missing: components | Show results with:components
  7. [7]
  8. [8]
    Chemglass Life Sciences Trap, Dry Ice, Cold Finger Only, Quantity
    4–8 day delivery 30-day returnsTrap, Dry Ice, Cold Finger Only. For use with the CG-1334 rotary evaporators. Image shown is the full rotary evaporator. Catalog No. 50-153-1085.Missing: static coolant
  9. [9]
  10. [10]
    Cold Finger - Abbess Instruments and Systems
    Abbess' Cold Finger are designed to augment HV and UHV vacuum chamber environments and act as the coldest element in the vacuum environment.Missing: equipment | Show results with:equipment
  11. [11]
    Cold Finger - Chemglass Life Sciences
    Filtration Equipment · Flasks · Flowmeters · Funnels · Gas Sampling Apparatus · Glassblowing Supplies · Gloves · Heat Guns · Heathrow Scientific Lab Supplies ...
  12. [12]
    Cs Labglass Borosilicate Glass Cold Finger Chiller Condenser - Odm
    Rating 4.0 (80) Product name:Cold Finger Condenser;Brand:CS Labglass;Material:Borosilicate Glass;Color:Transparent;Length(bottom to joint):100/150/200/220/250mm;Joint:14/20 ...
  13. [13]
    Heqi Cold Finger Condensers - Efficient & Durable Solutions
    Material Construction. Cold finger condensers are commonly constructed from high-purity glass (e.g., borosilicate) and stainless steel (typically 304 or 316L).
  14. [14]
    Cold trap cooling finger two-piece S29-Z / SL29-Z - KGW – Isotherm
    Jul 29, 2024 · LN2 or CO2 is used for cooling. The coolant should be at least 50°C colder than the condensation temperature of the substance.Missing: dry ice static
  15. [15]
    [PDF] UHV Flow Cryostats - CRYO Industries
    cold finger can be selected to fit exactly your chamber. Constructions is all welded stainless steel with low vapor pressure silver brazed copper joints.
  16. [16]
    Cold finger – Knowledge and References - Taylor & Francis
    A cold finger is a device made of copper that is positioned inside a vacuum-tight jacket, typically used for cooling purposes.<|control11|><|separator|>
  17. [17]
    Scientific Glassblowing-Technique for Cold Fingers-ring seal Part A
    Mar 13, 2013 · Part A Ring Seal and large in lathe bend (#25 o-ring joint). I was at the American Scientific Glassblowing Society's Symposium in Corning NY ...Missing: machining 3D printing
  18. [18]
    Cold trap cooling finger V2A S54K16-Z / S54K25-Z - KGW – Isotherm
    Jul 29, 2024 · The cooling finger is for gas purification, made of stainless steel, with high chemical and thermal resistance, and a simple, cost-effective ...
  19. [19]
    CAM Logic + KAMAX: Providing Solutions Using Metal 3D Printing ...
    They needed a quicker solution for producing transfer fingers for a cold forming machine. Traditionally, the fingers would be machined, and the lead times were ...
  20. [20]
    [PDF] Dynamic Mismatch Between Bonded Dissimilar Materials
    This dynamic mismatch varies with the bonded material shapes and sizes, surface characteristics, and heating or cool ing conditions and times and may be several.Missing: cold finger
  21. [21]
    How to Manage Stresses Caused By CTE Mismatches
    Sep 22, 2025 · One of the approaches to mitigate the differences in thermal expansion, is to select an adhesive with as low thermal expansion coefficient as possible.Missing: cold finger
  22. [22]
    Cold Finger Condenser 100mm In Length Below The 19/22 Inner ...
    Free delivery over $300Cold Finger Condenser Glass Condenser Laboratory Glassware Lab Glassware Laboy Glass. Special Price $21.11 Regular Price $32.67. Qty. Add to Cart. Details.Missing: cost | Show results with:cost
  23. [23]
    Cold Trap 2" Stainless Steel - BVV
    In stockThis 2" stainless steel cold trap, made of 304 steel, is for use with the Polyscience IP60, has a temperature rating of -200 to 200°C, and has 2 1/4" FNPT ...
  24. [24]
    Vacuum Systems & Traps | Environmental Health & Safety (EHS)
    For a cold source, it is recommended to use a mixture of dry ice and solvent (isopropanol or ethanol are recommended). Use of liquid nitrogen is strongly ...Missing: finger | Show results with:finger
  25. [25]
    [PDF] Laboratory Safety Manual 2018 - University of Louisville
    Only use liquid nitrogen in sealed or evacuated equipment and with extreme caution. A slurry of dry ice and isopropanol or ethanol is suitable for most ...Missing: coolant | Show results with:coolant
  26. [26]
    Water Circulators & Cold Traps - Yamato USA
    15-day returnsWater Circulators & Cold Traps · ​ · For Frugal Lab Managers · Easy to Customize · ​ · < Half the Cost of Competitors · Quick Draining · ​Closed-Loop Water Saving ...
  27. [27]
    [PDF] Development and Analysis of Cold Trap for Use in Fission Surface ...
    To reach a specified cold trap temperature, a coolant system must be incorporated into the cold trap design. The coolant design is based largely on the type of ...<|separator|>
  28. [28]
    [PDF] Cold Trap GKF 1000i - Manual - AJVS
    ☞ Check coolant level in the cold trap during operation at appropriate intervals. Coolant may overflow unexpectedly, e.g., in case of large amounts of gas.
  29. [29]
    [PDF] Use of Sublimation Apparatuses Revision Date: 11/01/19 Prepared By
    Nov 1, 2019 · ... cold finger. What is left on the cold finger is the pure product (or ... Cooled by dry ice and acetone (or another suitable cooling ...
  30. [30]
    [PDF] Too Cool to Resist - chess.cornell.edu
    Jun 25, 2010 · At this point, the liquid nitrogen directly contacts the cold finger, causing rapid cooling as evidenced by the increased boiling of the ...
  31. [31]
    [PDF] An experimentally validated heat and mass transfer model for wax ...
    The “cold finger” consists of a double-walled hollow 10-mm-outer-diameter cylindrical stainless steel tube with a circulating coolant flowing downward along the ...
  32. [32]
    [PDF] DRAF1T June 19, 2007 - NASA Technical Reports Server (NTRS)
    Jun 19, 2007 · Three different experimental configurations were made using the cold finger apparatus. Configuration one with no aerogel insulation is shown in ...
  33. [33]
    [PDF] Cooling the Dark Energy Camera CCD array using a closed-loop, two
    The copper nitrogen condenser is attached directly to the cryocooler cold finger ... The foam insulated valve box is replaced with a vacuum insulated box.
  34. [34]
    Fourier's Law of Heat Conduction - an overview | ScienceDirect Topics
    Fourier's law of heat conduction is defined as the relationship between heat flux and the temperature gradient in a material, expressed mathematically as q = -k ...
  35. [35]
    [PDF] A LN2 Based Cooling System for a Next Generation Liquid Xenon ...
    Sep 20, 2019 · This can be split into the thermal resistance of the cold finger material itself and a term describing the condensation heat transfer which ...
  36. [36]
    Effect of Temperature Difference on In-Tube Condensation Heat ...
    Aug 13, 2016 · The heat transfer coefficient is shown to increase with temperature difference, with this effect diminishing with larger temperature differences.
  37. [37]
    [PDF] Modeling of the Coldfinger Water Exhauster for Advanced TEG ...
    ... condensation and removal of the vapor at the top of the equipment, where a cold pipe (i.e. the “cold finger”) is located. It is typically reported that ...
  38. [38]
    Temperature controlled cold trap for a vapour deposition process ...
    Using nitrogen as the heat transfer gas has the added benefit of preventing frost buildup and possible plugging of the cold finger inlet tube. [0021] This ...
  39. [39]
    [PDF] Caffeine experimental
    As the sublimate collects, periodically remove the "cold finger" very carefully and scrape the pure caffeine onto glassine paper or into a preweighed vial.
  40. [40]
    Dean-Stark apparatus | Resource | RSC Education
    The apparatus allows the water to be separated from the condensed azeotrope preventing it from returning to the reaction mixture.
  41. [41]
    Rotary Evaporators - Lab Manager
    High-efficiency trapping of low-boiling solvents is achieved with a “cold finger” charged with dry ice and acetone. Vacuum is probably the broadest rotovap ...
  42. [42]
    Rotary Evaporators for Ethanol Extraction - Temperature & Uses
    Jan 7, 2019 · For ethanol extraction with dry ice, a rotary evaporator with a cold finger glass condenser is ideal. A coldfinger configuration is common ...<|control11|><|separator|>
  43. [43]
    Liquid Nitrogen Cold Finger - LACO Technologies
    LACO's Liquid Nitrogen Cold Finger traps contaminants and moisture, protecting equipment and improving vacuum performance.Missing: coolant circulating
  44. [44]
    Cold Traps - Vacaero
    Sep 1, 2017 · Cold traps are added to vacuum pumping systems either to remove unwanted contaminants (eg water, solvents, acidic or alkaline compounds) from the gas stream.
  45. [45]
  46. [46]
    Cross-Nucleation between ROY Polymorphs
    Crystallization by vapor condensation was carried out in a sublimation apparatus in which seeds of ROY crystals were affixed to the coldfinger maintained at ...
  47. [47]
    [PDF] High-temperature CVD silicon films for crystalline silicon thin ... - KOPS
    cold finger depends on the properties of the process gas: a large thermal ... proto-type CVD reactor for industrial scale production. 6.1.4 Efficiency ...
  48. [48]
    [PDF] Reactors Catalog - Ace Glass
    ... Dimensions in Millimeters. 3.0. 6.5. 10.5. 3.5. 7.1. 10.4. 3.0. 6.0. 10.0. 4.0. 8.9. 12.5. 5.0. 8.4. 11.5. 7.7. 12.5. 12.9. 7.3. 13.8. 16.2. Use with. Use with.
  49. [49]
    Vacuum Trap, Dewar Style - Scientific Solutions
    Our Vacuum Trap (cold trap) features a Dewar-style cold finger condenser and has a large opening at the top. It's perfect for use with dry ice, acetone or ...
  50. [50]
    Lab Grade Cold Traps For Vacuum Pumps | BVV
    $$10 delivery 30-day returnsBVV carries a wide selection of cold traps to protect your pumps from condensable vapors. Shop professional quality cold traps for vacuum pumps, ...
  51. [51]
    Cold Trap 4" Stainless Steel - BVV
    This Stainless Steel Cold is designed and intended for use with the Polyscience IP100 Cold Finger (Can also be used with dry Ice) to create a cold trap.Missing: corrosive environments
  52. [52]
    : Stainless Steel Cold Traps - Finemech
    Stainless steel cold traps are available for LN2 and dry ice (CO2), some with glass or stainless steel dewar flasks, and some with two sections.Missing: industrial | Show results with:industrial
  53. [53]
    Microfluidic Cold-Finger Device for the Investigation of Ice-Binding ...
    Sep 20, 2016 · A new, to our knowledge, apparatus designed to generate a controlled temperature gradient in a microfluidic chip, called a microfluidic cold finger (MCF).
  54. [54]
    Thermoelectric cooler (TEC) based thermal control system for space ...
    These cold fingers perform the function of an intermediate link which provides area for heat pipes to be attached and also transports the heat from the detector ...
  55. [55]
    SOME NEW FORMS OF LABORATORY APPARATUS.1
    SOME NEW FORMS OF LABORATORY APPARATUS.1. Click to copy article linkArticle ... Journal of the American Chemical Society. Cite this: J. Am. Chem. Soc. 1912, 34, ...
  56. [56]
    An apparatus for large-scale sublimation - ACS Publications
    Presents an apparatus that is faster than the standard cold-finger type apparatus for vacuum sublimation.
  57. [57]
    Company History | Buchi.com
    In 1957, BUCHI developed a world first: the rotary evaporator, which separates substances with different boiling points, and greatly simplifies work in ...Missing: cold finger 1970s
  58. [58]
  59. [59]
    Laboratory technique in organic chemistry : Wiberg, Kenneth B
    Nov 18, 2014 · Laboratory technique in organic chemistry. by: Wiberg, Kenneth B. Publication date: 1960. Topics: Chemistry, Organic. Publisher: New York, ...
  60. [60]
    [PDF] for Cryogenic - NASA Technical Reports Server (NTRS)
    The emphasis was to be on low temperature, closed cycle cooler technology; however, higher temperature coolers (77 K), with technology applicable to the low ...Missing: coolants | Show results with:coolants
  61. [61]
    Laboratory Automation - 2023 - Wiley Analytical Science
    Feb 21, 2023 · The first automated liquid handling systems emerged in the 1980s as a result of further electrotechnical developments. The development of ...
  62. [62]
    3D printed laboratory equipment to measure bulk materials in ...
    Oct 15, 2022 · The aim of this study was to investigate the possibility of using instruments made by material extrusion 3D printing method for measurement of selected ...Missing: finger | Show results with:finger
  63. [63]
  64. [64]
    The Organic Chem Lab Survival Manual: A Student's Guide to ...
    A hands-on guide to mastering organic chemistry lab techniques, safety protocols, and interpreting spectroscopic data, tailored for undergraduate students.Missing: cold | Show results with:cold
  65. [65]
    SOP: Cryogens and Dry Ice | PennEHRS - UPenn EHRS
    Jun 26, 2025 · Even brief skin contact with a cryogen, dry ice or non-insulated equipment parts can cause cold burn and frostbite. Prolonged contact can result ...
  66. [66]
    Cryogenic Materials | Environmental Health & Safety
    Cryogenic materials have hazards including fire, explosion, frostbite, asphyxiation, and pressure buildup. They can cause cold burns and frostbite, and ...<|separator|>
  67. [67]
    Dry ice process - CRYONOMIC
    On impact the pellets vaporize to carbon dioxide gas and increase in volume by a factor of 700. Due to this expansion the contaminant is lifted and separated ...
  68. [68]
    Plastic Secondary Container Shatters Due to Dry Ice Sublimation
    In this case, sublimation of dry ice led to gas buildup and overpressurization of the secondary container. In addition, the low temperature of dry ice likely ...Missing: cold finger
  69. [69]
    Physical Hazards | Division of Safety and Risk Services
    Liquid and solid cryogenics can cause severe cold contact burns by the liquid, and frostbite or cold exposure by the vapor. Dispensing areas need to be well ...
  70. [70]
  71. [71]
    [PDF] Laboratory Safety Guidance - OSHA
    The extent of detail on specific hazards provided in this document is dependent on the nature of each hazard and its importance in a laboratory setting.
  72. [72]
    Working with Chemicals - Prudent Practices in the Laboratory - NCBI
    Use laboratory chemical hoods and other ventilation devices to prevent exposure to airborne substances whenever possible. Do not underestimate hazards or risks.
  73. [73]
    [PDF] A Guide to Safe Handling of Laboratory Glassware
    Always use glassware free from breaks, cracks, chips, and nicks. • Before working with glassware, always inspect it for defects. ... Strains on joints can crack.
  74. [74]
    Glassware Safety
    Unfreezing Glass Joints – Glass joints may freeze/lockup if left together over time unlubricated, exposed to adhesive chemicals, or exposed to strong bases ...
  75. [75]
    [PDF] NESLAB ThermoFlexTM Recirculating Chillers (Basic Controller)
    ... flow to a suitable low-end calibration point (avoid a zero flow rate). Ensure the flow is stable. The controller will flash between LoFLo and the flow rate.Missing: coolant | Show results with:coolant
  76. [76]
    [PDF] 7 Working with Laboratory Equipment - Auburn University
    Keep it closed until cool. Remove all mercury from the cold oven with the use of appropriate cleaning equip- ment and procedures (see Chapter 6, section 6.C ...
  77. [77]
    [PDF] LABORATORY SAFETY MANUAL
    Check frequently for blockages in the cold trap. d. Use isopropanol/dry ice or ethanol/dry ice instead of acetone/dry ice to create a cold trap. Isopropanol ...
  78. [78]
  79. [79]
    How to Clean Laboratory Equipment - Mettler Toledo
    This article will discuss why cleanliness matters and describe best practices for cleaning laboratory instruments, common mistakes to avoid, and the broader ...
  80. [80]
    [PDF] WORK SAFELY WITH DRY ICE - UW Environmental Health & Safety
    To dispose of dry ice, place it in a well-ventilated area at room temperature; the remainder of the ice will sublimate away. • Never dispose of dry ice in a ...Missing: best | Show results with:best
  81. [81]
    Cryogenic Materials and Dry Ice | The University of Vermont
    Contact hazard: dry ice is a cryogenic material that causes severe frostbite upon contact with skin.