The Fern test, also known as the ferning test or amniotic fluid crystallization test, is a simple, rapid bedside diagnostic procedure used in to detect the presence of in vaginal secretions, thereby confirming premature (PROM) during , typically from the second onward. This test relies on the unique property of , which contains high concentrations of and other salts, to form a characteristic microscopic "fern-like" or arborized crystalline pattern when a thin smear of the fluid is allowed to air-dry on a and examined under low-power . The ferning pattern arises due to the and of these salts, distinguishing from normal vaginal secretions, urine, or other contaminants that do not produce this structure. The concept of ferning was initially described in 1945 by in the context of cervical mucus changes during , but its application to detection was formalized in 1955 by László Kardos and Mária Tamási as a qualitative to aid in diagnosing membrane rupture. Over time, it has become a standard component of the clinical evaluation for suspected PROM, often combined with other tests like the nitrazine (pH) test or more modern immunoassays such as AmniSure for improved accuracy, though it remains valued for its low cost, speed (results in 5-10 minutes), and minimal equipment requirements in resource-limited settings. The test's historical significance lies in its role in reducing maternal and fetal risks associated with undetected PROM, such as chorioamnionitis or preterm labor, by enabling timely interventions like administration or delivery planning.

Overview

Definition and principle

The Fern test is a simple, non-invasive bedside diagnostic method that identifies the presence of specific bodily fluids through the observation of fern-like (arborized) crystal patterns formed upon drying under a microscope. This test leverages the unique biophysical properties of fluids such as amniotic fluid or estrogen-influenced cervical mucus to produce distinctive branching structures, distinguishing them from other secretions. The principle of the Fern test is rooted in the process triggered by of fluids containing high concentrations of electrolytes and proteins. In , which has an approximate concentration of 0.9%, and in cervical mucus under elevated levels, the of concentrates the solutes, leading to the ordered assembly of salt crystals into intricate, fern-like patterns resembling plant fronds. This -induced formation occurs as is lost, concentrating the solutes and promoting anisotropic around protein scaffolds like mucins in cervical mucus. In contrast, secretions lacking these specific electrolyte-protein compositions, such as non-estrogenized cervical mucus or typical , dry into amorphous, non-branching patterns without the characteristic arborization. Microscopically, the fern patterns are visualized at magnifications of 100-400x, where the branching structures span the dried sample, often covering the entire in positive cases. The biophysical mechanism emphasizes the role of in aligning sodium and crystals along axes, creating the diagnostic topology without requiring complex equipment.

Primary applications

The Fern test serves a key role in fertility assessment by detecting the estrogen-induced ferning pattern in cervical mucus, which signals the fertile window during the periovulatory phase of the . This application allows individuals to identify peak fertility mid-cycle, typically around days 12 to 14, when levels rise and promote the crystallization of in the mucus under microscopic examination. By confirming timing, the test supports methods, such as the , enabling couples to optimize conception efforts or practice contraception without hormonal interventions. In obstetric practice, the Fern test is widely applied to diagnose premature rupture of membranes (PROM) through the identification of ferning in vaginal secretions contaminated with . This confirmation is essential after 20 weeks of in cases of suspected , as it helps differentiate true rupture from other causes of fluid leakage, thereby guiding to mitigate risks like preterm labor and . The test's utility lies in its ability to provide rapid bedside evidence, complementing clinical evaluation in high-risk pregnancies.

History

Origins in fertility testing

The fern test emerged in the mid-20th century as a key component of cervical mucus analysis for detecting ovulation in gynecological fertility monitoring. It was first described in 1945 by Georgios N. Papanicolaou, who observed that dried samples of cervical mucus formed intricate, fern-like crystalline patterns under microscopic examination during the estrogen-dominant pre-ovulatory phase of the menstrual cycle. This phenomenon, termed "ferning," was linked to elevated estrogen levels influencing mucus composition, providing an early non-invasive method to assess hormonal fluctuations and fertility windows. Building on this foundation, the test was further integrated into during the and through advancements in techniques. Research in , initiated in 1953 by Drs. John and Evelyn Billings, focused on systematic observation of cervical mucus changes to identify fertile periods, culminating in the formalization of the in 1964. The method primarily relied on self-reported sensations and macroscopic visual characteristics of mucus at the , though microscopic ferning from Papanicolaou's earlier work provided a related confirmatory approach in broader practices. The primary purpose of the fern test in its early fertility applications was to enable reliable tracking of estrogen peaks, which alter mucus properties to facilitate sperm survival and transport, thereby supporting non-hormonal approaches to contraception and conception planning. By the 1970s, techniques like the Billings method were adopted in programs worldwide, with the sponsoring multicenter trials from 1977 to 1981 across several countries to evaluate the effectiveness of ovulation-based methods, demonstrating their viability for diverse populations seeking hormone-free fertility management. This period marked a significant milestone in promoting accessible, user-directed tools. Later applications extended the test to diagnostics, though its foundational role remained in ovulation assessment.

Adoption in obstetrics

The fern test, building on principles of cervical mucus analysis in fertility testing, was adapted for obstetric use in the mid-20th century to detect amniotic fluid leakage associated with premature rupture of membranes (PROM), following observations that amniotic fluid's high electrolyte content—particularly sodium chloride—produces a similar crystallization pattern upon air-drying. Initial clinical reports emerged in the late 1950s and early 1960s, with Kardos and Tamási first reporting its application to confirm membrane rupture in a 1955 study published in Orvosi Hetilap, followed by validation studies such as Smith and Callagan (1962) on amniotic fluid crystallization and Tricomi et al. (1966) reporting 97.8% accuracy for the arborization (ferning) test when sampling near the introitus to minimize contamination. By the late 1960s, Friedman et al. (1969) highlighted the test's enhanced reliability when combined with patient history and nitrazine testing, achieving 93.1% diagnostic accuracy. During the , research focused on improving the test's specificity in clinical scenarios involving vaginal fluid pooling, with studies emphasizing proper sample collection from the posterior fornix to distinguish ferning from artifacts caused by cervical mucus or contaminants. The test gained further prominence in the through investigations validating its role in preterm (PPROM), where timely diagnosis is critical to prevent complications like chorioamnionitis; for instance, evaluations during this era confirmed its utility as a rapid bedside method in high-risk preterm cases, complementing assessments. By the 1990s, the fern test had evolved from a qualitative adjunct in fertility evaluation to a standard component of emergency obstetric protocols for PROM diagnosis, with integration into guidelines from organizations like the American College of Obstetricians and Gynecologists (ACOG), which endorsed its use alongside clinical history and speculum examination as an accessible, low-cost tool in resource-limited settings. This shift underscored its transition to a cornerstone of in , particularly for confirming membrane integrity in labor and delivery units.

Procedure

Sample collection

The Fern test involves obtaining a sample of or to detect characteristic ferning patterns indicative of high levels during or membrane rupture in . The general for sample collection employs a sterile speculum inserted into the in the dorsal , without the use of lubricants or antiseptics. A sterile or then collects fluid from the posterior or pooled secretions, avoiding contact with the vaginal walls or to minimize contamination. In , mid-cycle cervical is collected directly from the external os during the presumed window. A inserts a speculum, cleanses the portio vaginalis with a if needed, and uses a suction (approximately 3 mm diameter) attached to a 10-mL to gently aspirate from the endocervical canal up to the internal os. Clinician-performed collection is preferred to ensure purity and accuracy. For obstetric applications in suspected premature , the sample is gathered from the posterior vaginal pool after speculum insertion, deliberately avoiding the os and . Collection follows any necessary only if it does not compromise sterility, with the swab or targeting pooled fluid to capture potential amniotic leakage. Key precautions include instructing patients to abstain from vaginal lubricants, douching, sexual intercourse, or antiseptic use for at least 24 hours prior to collection, as these can alter fluid composition and lead to contamination. Typically, 0.5-1 mL of fluid suffices for the test, rolled onto a glass slide for subsequent drying.

Examination and analysis

Following sample collection, a thin layer of the fluid is spread across the center of a clean glass microscope slide using a sterile swab or pipette to ensure even distribution without clumping. The slide is then allowed to air-dry at room temperature for 5 to 10 minutes, or until no moisture is visible, without applying heat, blowing, or a coverslip to avoid altering the crystalline formation. Examination requires a standard or phase-contrast , utilizing low-power (10×) objectives for initial focusing and scanning, followed by high-power (40×) objectives for detailed observation, achieving total magnifications of 100× to 400×; no or additional reagents are needed. During analysis, multiple fields across the dried are systematically scanned—often in an "S"-shaped pattern under low —to locate areas of interest, with findings documented via photography if a camera attachment is available for record-keeping or consultation. The examination typically requires 5 to 10 minutes in total. In low-resource settings, a basic bright-field is sufficient for reliable performance of the test.

Interpretation

Positive results

A positive result in the Fern test is identified by the observation of a characteristic arborization pattern, consisting of distinct branching, leaf-like crystalline structures resembling fronds, when the dried sample is examined under low-power . These patterns, which can vary from fine, delicate fronds to more coarse and prominent s, arise from the and protein components in the fluid interacting during evaporation. In fertility testing, a positive Fern pattern in cervical mucus signifies elevated estrogen levels associated with the periovulatory phase, indicating the fertile window when sperm survival and transport are optimal. This crystallization typically emerges during the periovulatory phase of the , coinciding with peak influence on composition just prior to . In obstetric applications, a positive result confirms the presence of , supporting a of premature rupture of membranes (PROM) or rupture at term, with reported positive predictive values as high as 92-100% in clinical evaluations. To minimize interpretive subjectivity, positivity is generally documented when the arborization is clearly evident in the examined microscopic field following air-drying of the sample.

Negative results

A negative result in the Fern test is identified by the absence of the characteristic branching, fern-like crystallization patterns when the dried sample is examined under a microscope at 100x to 400x magnification. Instead, the sample typically displays amorphous sheets, globules of mucus, or no discernible crystalline structure across multiple microscopic fields. In the context of fertility testing, a negative Fern test suggests the patient is in a non-ovulatory phase of the menstrual cycle, characterized by lower estrogen levels, such as during the follicular or luteal phases, where cervical mucus lacks the properties needed for ferning. If negative results persist throughout the cycle, this may indicate anovulation or ovulatory dysfunction. For obstetric applications, particularly in evaluating premature rupture of membranes (PROM), a negative result indicates that no amniotic fluid is detected in the vaginal sample, thereby helping to rule out PROM in the absence of other confirmatory signs. The negative predictive value (NPV) of the Fern test for PROM is generally high, for example 95.8% in some studies, though it can vary based on factors like sample quality and timing. If clinical symptoms suggestive of PROM, such as persistent leakage, continue despite a negative Fern test result, follow-up is essential and may involve repeating the test after 1 to 2 hours or integrating it with additional diagnostics like ultrasound assessment of amniotic fluid volume.

Clinical utility

Accuracy metrics

The Fern test demonstrates variable accuracy in diagnosing premature rupture of membranes (PROM), with reported sensitivity ranging from 74% to 100% and specificity from 77% to 100% across studies, though performance is often modest in non-laboring women with nonspecific vaginal fluid loss. In a key 1994 prospective study of 120 non-laboring women, the test achieved a sensitivity of 51.4% and specificity of 70.8%, correctly predicting membrane status in 63% of cases, highlighting its limitations in low-volume or trace leakage scenarios compared to pooled amniotic fluid where accuracy improves. A 2021 narrative review of diagnostic strategies for PROM summarized conventional Fern test metrics from comparative studies as 77.8% sensitivity, 79.3% specificity, 36.8% positive predictive value (PPV), and 95.8% negative predictive value (NPV), with overall accuracy around 79.1%; another prospective analysis in the same review reported 84.5% sensitivity and 78.2% specificity, yielding 81.4% accuracy. In low-risk settings without labor, positive predictive values for PROM detection typically range from 80% to 92%, while negative predictive values fall between 83% and 96%, making a negative result more reliable for ruling out rupture. The American College of Obstetricians and Gynecologists (ACOG) guidelines acknowledge the as a screening tool alongside testing but emphasize its modest diagnostic value, particularly in non-laboring patients, based on aggregated evidence from 1990s trials like de Haan et al. and subsequent meta-analyses through the . Data from the , including a 2023 review, confirm overall accuracy near 85% for detection when combined with clinical assessment, though immunoassay alternatives like PAMG-1 often outperform it. For ovulation detection in fertility applications, the salivary Fern test achieves approximately 85-90% accuracy when samples are timed correctly around the periovulatory , correlating with peaks that induce ferning patterns 1-2 days before to 1 day after as verified against ultrasonography. A 2018 prospective study of 100 women reported 86.5% overall accuracy, with of 88% and specificity of 85% for identifying the fertile window in regular cycles. However, accuracy drops in irregular cycles due to inconsistent surges, with detection rates as low as 36.8% on the exact day of and up to 58.7% uninterpretable results in some evaluations. Evidence from 2010s-2020s studies, including comparisons with and ultrasound, supports its utility as a non-invasive tool with 80% and 78% specificity in controlled settings, though it is less reliable standalone for irregular menstrual patterns.

Limitations and sources of error

The Fern test is susceptible to false positive results primarily due to of the sample with cervical mucus, which can exhibit ferning even during , as well as , , or . High salt concentrations in non-amniotic fluids, such as from or fingerprints containing , can also induce crystallization patterns mimicking true ferning. False negative results arise from dilute amniotic fluid, often following prolonged greater than 24 hours or when only minimal fluid volume has leaked, resulting in insufficient electrolytes for . Sampling errors, such as inadequate collection from the posterior where fluid pools, further contribute to missed detection. Additionally, blood, cellular debris, or contamination can inhibit , while insufficient drying time (less than 10 minutes) prevents the development of observable ferns. In fertility applications for ovulation detection, the test's reliability diminishes with hormonal imbalances, such as deficiencies, which alter composition and prevent consistent ferning. In obstetric contexts, vaginal infections like or , along with meconium-stained fluid, can obscure microscopic patterns and lead to interpretive errors. To mitigate these sources of error, clinicians should employ sterile technique during posterior fornix swabbing to minimize and examine multiple fields under the for representative patterns. The test is not recommended as a standalone diagnostic, particularly for high-stakes decisions like confirming premature , and should be paired with adjunct methods such as testing or immunoassays.

Alternatives

Tests for premature rupture of membranes

The diagnosis of premature rupture of membranes () relies on a combination of clinical evaluation and diagnostic tests, with several alternatives to traditional methods like the Fern test offering varying levels of accuracy and invasiveness. The American College of Obstetricians and Gynecologists (ACOG) recommends integrating these tests with history, , and observation of fluid pooling to confirm , emphasizing the avoidance of unnecessary invasive procedures. The test is a pH-based bedside that detects the alkaline nature of , typically turning the indicator paper blue if the pH exceeds 6.5. It provides rapid results but has moderate (ranging from 76% to 93%, decreasing over time after rupture) and specificity (around 81%), with common false positives due to contamination from blood, urine, semen, or . Immunoassays targeting placental alpha-microglobulin-1 (PAMG-1), such as the AmniSure or ROM Plus test, represent point-of-care options that detect this protein unique to with high reliability. These tests exhibit of approximately 96-97% and specificity of 98-99%, outperforming pH-based methods in equivocal cases and maintaining accuracy even with trace fluid volumes or contamination. ACOG and the Society for Maternal-Fetal Medicine (SMFM) guidelines from the 2020s favor PAMG-1 assays over older tests like or in ambiguous presentations due to their superior predictive values. Ultrasound evaluation of the (AFI) or single deepest pocket serves as a non-invasive adjunct, identifying (AFI <5 cm) suggestive of PROM, though it is indirect and less sensitive for early or partial ruptures. It is routinely recommended by ACOG to assess fetal and volume alongside other diagnostics, with supporting but not confirming the diagnosis. Instillation tests, such as intra-amniotic injection of dye (historically or ), involve to instill the agent and observation for vaginal leakage, providing definitive confirmation in unclear cases. However, these are invasive, carrying risks of , , iatrogenic preterm labor, and fetal harm (e.g., with ), and are generally discouraged in modern practice per ACOG and SMFM guidance. Tests detecting insulin-like growth factor binding protein-1 (IGFBP-1), such as the Actim PROM , identify this marker in cervicovaginal secretions, with sensitivity around 74% and specificity of 78%, though performance varies with and contamination. These are useful as rapid alternatives but are less accurate than PAMG-1 assays, and guidelines suggest their use in combination with clinical findings rather than standalone.

Methods for ovulation detection

Ovulation detection methods provide alternatives to microscopic examination of cervical mucus, such as the Fern test, enabling women and clinicians to identify the fertile window through hormonal, physiological, or technological approaches. These techniques are particularly useful in fertility tracking, , and evaluations, offering options that range from at-home monitoring to clinical diagnostics. Ovulation predictor kits (OPKs) are over-the-counter urine tests that detect the (LH) surge, which typically precedes by 24 to 36 hours and signals the start of the fertile window. These kits, designed for home use, involve dipping a test strip in urine or using a midstream format, with results appearing as color changes or lines indicating the LH threshold. Manufacturers report detection accuracies exceeding 90% for the LH surge, with some studies showing 95% or higher concordance with LH levels, though in timing or interpretation can affect reliability. OPKs are convenient for daily testing during the mid-follicular phase but do not confirm itself, only predicting it. Basal body temperature (BBT) tracking involves measuring oral or vaginal temperature each morning before any activity, revealing a biphasic pattern where temperature rises by approximately 0.5°F (0.3°C) post- due to progesterone influence. This method is inexpensive, requiring only a digital thermometer, and can be charted manually or via apps to confirm ovulation retrospectively after the shift occurs. However, it is less predictive for timing intercourse, as the rise happens after ovulation, and factors like illness or poor can cause variations, leading to detection failures in up to 20% of ovulatory cycles. Transvaginal ultrasound monitoring serves as the gold standard for follicular tracking in clinics, using high-frequency probes to visualize ovarian follicles' growth, typically reaching 18-25 mm before . Performed serially during the , it allows precise assessment of follicle number, size, and endometrial thickness, guiding timed or assisted . This clinical method provides direct of events, such as follicle rupture, with high accuracy but requires specialized equipment and trained sonographers. Symptom-based apps integrate user-input data on basal temperature, cervical mucus observations, and menstrual cycle lengths to algorithmically predict and fertile days. Apps like Natural Cycles, cleared by the FDA in 2018 as a method, combine these inputs for detection with reported typical-use effectiveness in identifying fertile windows, validated through clinical studies of thousands of cycles. Such digital tools offer accessibility via smartphones but rely on consistent user adherence for accuracy. Hormonal blood tests measure serum levels of progesterone or to confirm , typically drawn mid-luteal phase (around day 21 of a 28-day cycle). Progesterone concentrations exceeding 10 ng/mL indicate successful and function, while levels below suggest ; tests can assess follicular development earlier. These lab-based assays provide definitive biochemical confirmation but are invasive, costly, and not suited for frequent home monitoring.

References

  1. [1]
    Ferning Pattern for Amniotic Fluid - AccessMedicine
    To distinguish between amniotic fluid due to membrane rupture and normal vaginal secretions in patients beyond the 20th week of pregnancy who present with ...
  2. [2]
    Point of Care- Ferning, PPM - MLabs
    The fern test is based on the ability of amniotic fluid to form a microscopic crystalline pattern that resembles fern leaves when the fluid air dries on a glass ...
  3. [3]
    [PDF] SUNY Downstate Medical Center -University Hospital of Brooklyn ...
    The Fern Test detects the leakage of the amniotic fluid from the membranes surrounding the fetus during pregnancy. Premature rupture of the membranes may lead ...
  4. [4]
    The Ferning and Nitrazine Tests of Amniotic Fluid Between 12
    Detection of amniotic fluid by use of pH was first described in 1927. The fern test was described in 1955. Both of these tests are extensively used by ...
  5. [5]
    Rupture of Membranes Evaluation | ACOG
    The combination of arborization, nitrizine and history was originally investigated in the 1960s, and found to have a diagnostic accuracy of 93.1%. More recent ...
  6. [6]
    Value of the fern test to confirm or reject the diagnosis of ruptured ...
    Value of the fern test to confirm or reject the diagnosis of ruptured membranes is modest in nonlaboring women presenting with nonspecific vaginal fluid loss.
  7. [7]
    Amniotic Fluid Crystallization Test for Ruptured Membranes - PMC
    A simple and inexpensive test is described which permits positive identification of amniotic fluid by its fern-type crystallization.Missing: principle | Show results with:principle
  8. [8]
    [PDF] Provider-Performed Microscopy Procedures - CDC
    Jun 30, 2016 · Fern Test . ... Trainer discusses principle of test procedure so that trainee understands scope and purpose of the test.
  9. [9]
    Fern Test
    The Fern Test is one of several tests used to detect rupture of the membranes. Vaginal secretions are inspected under a microscope for crystallization or a ...
  10. [10]
    Mucin and salt combination simulate typical fern-like pattern of ...
    Mar 19, 2024 · MUC3 and NaCl salt combination produces more realistic fern-like patterns compared with MUC2 or BSA and salt combination.
  11. [11]
    L-type (Loaf) Cervical Secretion Crystallization Directionality ...
    Jun 14, 2023 · ... L-type (Loaf) Cervical Secretion Crystallization Directionality ... fern leaves”. This pattern appears to correlate with the concentration ...Missing: principle | Show results with:principle
  12. [12]
    [PDF] Assessment of Salivary Secretion for the Prediction of Ovulation by ...
    Jan 15, 2021 · Fern test is a detection of a characteristic 'fern like' pattern of cervical mucus when a specimen of cervical mucus dries on a glass slide and ...
  13. [13]
    Efficacy of methods for determining ovulation in a natural family ...
    Mucus sensations and characteristics yielded a 48.3% correlation when simultaneously evaluated with ovulation. Beta-glucuronidase levels yielded a 27.7% ...
  14. [14]
    [PDF] ACOG PRACTICE BULLETIN
    Feb 20, 2020 · This Practice Bulletin is updated to include information about diagnosis of PROM ... test of vaginal fluid, or arborization (ferning) of dried.
  15. [15]
    Preterm Premature Rupture of Membranes: Diagnosis and ... - AAFP
    Feb 15, 2006 · Once the fluid has dried on the slide, the physician can check for ferning (arborization) under a low-power microscope. The presence of ferning ...
  16. [16]
  17. [17]
    The Quest - leading to the discovery of the Billings Ovulation Method
    The medical research which led eventually to the recognition, development and refinement of the Billings Ovulation Method® began in Melbourne in 1953.
  18. [18]
    The Fern Reaction of Cervical Mucus: Part I. The Effect of the ... - NIH
    The fern reaction of endocervical mucus was tested in 100 non-pregnant and 200 pregnant women with a view to establishing the relationship of this fern pattern ...
  19. [19]
    (PDF) The Billings Method of Family Planning: An Assessment
    Aug 7, 2025 · This paper outlines the method's recent history and goes on to discuss its physiological basis, its use-effectiveness as measured in a number of ...
  20. [20]
    Utility of Fern Test to Determine Rupture of Membranes
    Sep 14, 2017 · The test is done by collection of fluid from the vagina which is then allowed to dry for 10 minutes on a slide.<|control11|><|separator|>
  21. [21]
  22. [22]
    Prelabor Rupture of Membranes - ACOG
    This Practice Bulletin is updated to include information about diagnosis of PROM, expectant management of PROM at term, and timing of delivery for patients ...Missing: Fern | Show results with:Fern
  23. [23]
    Fern test; Amniotic Fluid Crystallization test - MercyOne Laboratory ...
    Used for the qualitative determination of the presence of amniotic fluid in a vaginal pool specimen.
  24. [24]
    Volume 5, Chapter 51. The Postcoital Test
    Davajan's method of cervical mucus collection. B. The catheter is gently ... Postcoital test data sheet. It should be mentioned at this point that the ...
  25. [25]
    [PDF] Chapter 6 - Diagnosis of Infertility - Princeton University
    When placed on a glass slide and allowed to dry, cervical mucus dries into a distinctive fern-like pattern. ... an In Vitro Cervical Mucus Penetration Test, ” Fer ...
  26. [26]
    The role of the fern test in the treatment of rhinitis - SciELO México
    The fern test is effective for assessing mucus alterations in patients with rhinitis and it could be included as a new parameter in the study of rhinitis.Missing: original | Show results with:original
  27. [27]
    Accurate Point-of-Care Detection of Ruptured Fetal Membranes - NIH
    May 9, 2016 · The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing.
  28. [28]
    When are women most fertile? - Blog - IVI Fertility
    Jan 30, 2019 · Ovulation normally takes place 12-16 days before the start of your next period. Thus, if you have a regular 28-day cycle (and of course many ...
  29. [29]
    [PDF] Comparison of fern and evaporation tests for detection of ruptured ...
    The positive and negative predictive values of the fern test were 92% and 96% and for the evaporation test were 89% and 98%. The evaporation test is a simple, ...
  30. [30]
    Comparison of Conventional Methods (Nitrazine Test, Ferning Test ...
    For the Ferning test, it has 85.7% sensitivity, 100% specificity, 100% PPD, and 87.5% NPD. Conclusion: The results obtained from our study differed from those ...
  31. [31]
    Current and Emerging Strategies for Prediction and Diagnosis ... - NIH
    Jun 30, 2021 · ... Fern test's diagnostic accuracy (60, 62). fFN, a family of ... test given the limited evidence on the diagnostic accuracy of tests in PROM.Missing: 1960s | Show results with:1960s
  32. [32]
    [PDF] Evaluation of Salivary Ferning for Predicting Ovulation in ...
    Jul 31, 2023 · emergence of ferning in vaginal mucous.9. According to Barbato M, the development of ferns may be a result of a rise in estrogenic activity ...<|control11|><|separator|>
  33. [33]
    Detection of ovulation, a review of currently available methods - PMC
    The history of salivary ferning test can be traced back to 1969. Dr. Biel ... natural family planning charts. Fertil Steril. 1989;51(3):430–434. [DOI] ...
  34. [34]
    ROM Plus®: accurate point-of-care detection of ruptured fetal ... - NIH
    Ferning's sensitivity was 99%, specificity 72%, with positive and negative predictive values of 80% and 99%. Finally, nitrazine testing had a sensitivity of 93% ...
  35. [35]
    Preterm and Term Prelabor Rupture of Membranes (PPROM ... - NCBI
    Oct 31, 2024 · Of note, cervical mucus can also produce a crystallized pattern. However, cervical mucus forms fern-like patterns in thick linear bands ...
  36. [36]
    Evaluation and Management of Premature Rupture of Membranes
    Mar 24, 2023 · The fern test also has a high chance of producing false positives and false negatives. ... negative test result [20]. It has been proposed that if ...
  37. [37]
    Ferning in amniotic fluid: Is it a useful indicator of ruptured ...
    Jan 14, 2019 · The presence of arborized crystals (ferning) in amniotic fluid is both sensitive (74%-100%) and specific (77%-100%) for diagnosing rupture of membranes in ...<|control11|><|separator|>
  38. [38]
    Non-Invasive Fetal Membranes Rupture Tests - Aetna
    For the fern test, fluid from the posterior vaginal fornix is swabbed onto a glass slide and allowed to dry for at least 10 minutes. The slide is then reviewed ...
  39. [39]
    Study the accuracy of salivary ferning test as a predictor of ovulation
    Jun 27, 2018 · Its accuracy was 86.5%. Conclusions: Salivary ferning test is a reliable test to detect fertile period of menstrual cycle. Hence can be use for ...<|control11|><|separator|>
  40. [40]
    Efficacy of methods for determining ovulation in a natural family ...
    The salivary ferning test had a 36.8% ovulation-detection rate the day of ovulation, but 58.7% of results were uninterpretable. Body temperature measurements ...
  41. [41]
    Ovulation Detection in Saliva, Is It Possible - Karger Publishers
    Sep 4, 2013 · Using a comparable mini-microscope to ovu-control, Cleofe Medina found a sensitivity of 53% and a specificity of 73% for saliva ferning in ...Missing: accuracy | Show results with:accuracy
  42. [42]
    The fingerprint, a false-positive fern test - PubMed
    The fingerprint, a false-positive fern test. Obstet Gynecol. 1989 May;73(5 Pt ... Substances. Sodium Chloride.
  43. [43]
    Diagnosis of premature rupture of membranes by assessment ... - NIH
    Fern test has also 13-30% false negative and 5-30% false positive results (13, 14). “Several studies have been conducted to find a definite, easy, noninvasive ...Missing: 1960s 1970s
  44. [44]
    Placental alpha microglobulin-1 (AmniSure(®) test) for detection of ...
    Results: In this study, the sensitivity and the specificity of PAMG-1 to diagnose PROM were 97.33 and 98.67%, respectively, compared with 84% sensitivity and ...
  45. [45]
    Premature Rupture of Membranes: Making the Diagnosis
    Oct 10, 2024 · ACOG does include pH and ferning, but they are associated with significant false positive and false negative rates, depending on the clinical ...
  46. [46]
  47. [47]
    Contemporary Diagnosis and Management of Preterm Premature ...
    The fern test refers to microscopic crystallization of amniotic fluid on ... cervical mucus as well as false-negative results due to technical error ...
  48. [48]
    Significance of detecting insulin‐like growth factor binding protein‐1 ...
    Jun 28, 2004 · The PROM test is strongly positive for values of IGFBP-1 above 50 µg/L and can detect IGFBP-1 at a minimum of 25 µg/L. The sensitivity, ...
  49. [49]
    Physiology, Ovulation And Basal Body Temperature - NCBI - NIH
    Charting the daily basal body temperature will show a noticeable increase of approximately 0.5 to 1 degrees F shortly after ovulation.
  50. [50]
    Basal body temperature for natural family planning - Mayo Clinic
    typically less than a 1/2 degree F (0.3 C) — when you ovulate. Ovulation has likely occurred when ...
  51. [51]
    Ovulation (Urine Test) - FDA
    Feb 4, 2018 · These tests can detect LH and E3G reliably about 9 times out of 10, but you must do the test carefully. How do you do this test? You add a few ...
  52. [52]
    Similar accuracy and patient experience with different one ... - PubMed
    Sep 24, 2024 · Ovulation predictor kit surge detection accuracy compared with blood LH surge was similar across the five kits (Easy@Home, 95.88%; Wondfo, 94. ...
  53. [53]
    Ovulation home test: MedlinePlus Medical Encyclopedia
    Apr 1, 2023 · Ovulation prediction test kits most often come with five to seven sticks. You may need to test for several days to detect a surge in LH. The ...
  54. [54]
    Accuracy of Basal Body Temperature for Ovulation Detection
    The results indicate that in approximately 20% of ovulatory cycles the BBT failed to demonstrate ovulation. Previous article in issue; Next ...
  55. [55]
    Transvaginal ultrasonography and female infertility | GLOWM
    An ultrasound examination is the gold standard for detecting/diagnosing polycystic ovaries. Developing a standardized definition that describes the ...
  56. [56]
    Follicle Monitoring and Endometrial Correlation
    Folliculometry is the gold standard investigation to monitor follicular development and growth, check for signs of ovulation corpus luteum (CL) integrity, and ...
  57. [57]
    Clinical Value of Three-Dimensional Transvaginal Ultrasound ... - NIH
    May 11, 2022 · Transvaginal ultrasound can not only accurately evaluate the ER of infertile women but also directly observe follicular development and monitor ...Missing: tracking | Show results with:tracking
  58. [58]
    [PDF] DE NOVO CLASSIFICATION REQUEST FOR NATURAL CYCLES
    A reti·ospective analysis ofpatient data was conducted to validate the accuracy ofthe algorithm in the identification of ovulation. The ovulation day was con ...
  59. [59]
    FDA clears Natural Cycles, controversial app for contraception | STAT
    Aug 10, 2018 · The FDA cleared an app that helps women keep track of when they're ovulating by logging their temperature. Not everyone is convinced it's a ...Missing: validation | Show results with:validation
  60. [60]
    Compare Digital Birth Control Methods | Natural Cycles News
    Mar 1, 2021 · The app's FDA clearance is based on the study of 700 women and 5,397 cycles. Real life evidence³. Natural Cycles monitors how the app works ...Missing: validation | Show results with:validation
  61. [61]
    Progesterone Test: MedlinePlus Medical Test
    Aug 5, 2025 · A progesterone test measures the level of progesterone in a sample of your blood. Progesterone is a hormone that's made mainly by the ovaries.
  62. [62]
    Progesterone, Serum - Mayo Clinic Laboratories
    Typically, day 21 to 23 serum progesterone concentrations of more than 10 ng/mL indicate normal ovulation and concentrations below 10 ng/mL suggest anovulation ...
  63. [63]
    Serum progesterone - UCSF Health
    Apr 1, 2023 · Serum progesterone is a test to measure the amount of progesterone in the blood. Progesterone is a hormone produced mainly in the ovaries.