Fact-checked by Grok 2 weeks ago

Pinhole occluder

A pinhole occluder is a simple, handheld diagnostic device consisting of an opaque disk or shield with multiple small apertures, typically 1.2 mm in diameter on a dark background, used by ophthalmologists, optometrists, and orthoptists to evaluate visual acuity. By permitting only central light rays to enter the eye through these pinholes, it temporarily reduces the effects of refractive errors and minor optical aberrations, allowing focused light to reach the retina without interference from scattered or peripheral rays. The principle behind the pinhole occluder relies on the stenopeic effect, where the small openings limit the bundle of entering the eye to near-parallel rays, effectively increasing and bypassing issues like , hyperopia, or during testing. Optimal sizes range from 0.94 mm to 1.75 mm to balance clarity and illumination, as smaller holes can cause while larger ones diminish the corrective benefit. This makes it an essential, cost-effective tool for quick assessments without the need for immediate . In clinical practice, the pinhole occluder helps distinguish refractive causes of reduced vision from pathological ones: improvement in acuity suggests correctable errors, while no change points to conditions like or requiring further investigation. It is also integral to specialized tests, such as the method, which uses the device with a near reading card under bright light to predict visual outcomes after . Widely available and portable, the pinhole occluder remains a fundamental component of routine eye examinations, offering reliable insights into visual function with minimal complexity.

Overview

Definition

A pinhole occluder is an opaque disk or paddle-shaped device featuring one or more precisely sized small holes, typically 1 to 2 in , drilled through its center. These holes, often multiple in number and arranged in a cluster, allow controlled light passage during testing while blocking peripheral rays. It serves as a fundamental diagnostic tool employed by ophthalmologists, optometrists, and orthoptists to evaluate and identify potential refractive issues during routine eye examinations. By holding the occluder in front of the patient's eye, clinicians can quickly assess whether reduced vision stems from correctable optical errors. Unlike pinhole glasses intended for extended wear to temporarily enhance clarity in daily activities, or pinhole intraocular lenses surgically implanted to correct vision permanently, the pinhole occluder is strictly a handheld, non-invasive for professional diagnostic purposes. Standard models are compact and portable, typically measuring 10 to 25 cm in length with a handle for easy manipulation, and constructed from durable, light-blocking materials such as , metal, or to ensure opacity and longevity in clinical use.

Principle of operation

The principle of operation of a pinhole occluder is based on the stenopeic effect, where a small restricts incoming light to paraxial (central) rays, thereby increasing the and reducing optical aberrations such as and . By limiting peripheral light rays that contribute to defocus and distortion, the pinhole minimizes diffraction blur and enhances image sharpness on the . This effect simulates natural constriction in bright light, allowing clearer vision without corrective lenses for certain optical issues. In cases of refractive errors like , hyperopia, or , the pinhole occluder improves by reducing the size of the blur circle formed on the due to defocus. Peripheral rays, which exacerbate blur in uncorrected eyes, are blocked, leaving only the more focused central bundle of . The diameter of the blur circle can be approximated by the : b \approx \left( \frac{p}{f} \right) \times \delta where b is the blur diameter, p is the effective pupil diameter, f is the focal length of the eye, and \delta is the defocus amount. The pinhole effectively reduces p, proportionally shrinking b and sharpening the retinal image. The optimal aperture size for a pinhole occluder is typically around 1.2 mm, which balances refractive error correction with minimal diffraction; smaller diameters (e.g., below 1 mm) increase diffraction blur, while larger ones diminish the stenopeic benefit. However, the pinhole provides no visual improvement if reduced acuity stems from non-refractive causes, such as media opacities (e.g., cataracts) or damage, as these issues affect light transmission or photoreceptor function independently of bundling.

Design and variations

Physical construction

The pinhole occluder is typically constructed from durable, opaque materials to ensure effective light blocking and ease of cleaning in clinical settings. Common materials include high-impact plastic for its strength and resistance to deformation, or flexible vinyl for lightweight handling and comfort. These are often finished in non-reflective black to minimize interference during visual testing. Standard dimensions facilitate precise manipulation and eye coverage without excessive bulk. The occluding disk or cup generally measures around 60 mm in diameter, while the handle ranges from 17 to 24 cm in length to allow comfortable one-handed use by examiners. The central pinhole is precisely machined to a diameter of 1 to 1.5 mm, often using mechanical drilling for uniformity and accuracy in light restriction. Ergonomic design prioritizes patient comfort and examiner efficiency. The disk is commonly cupped to conform gently over the eye without applying pressure, reducing discomfort during prolonged assessments. Some models incorporate a flat or slightly frosted surface on the occluding side to permit observer visibility of the patient's eye position. As a low-risk diagnostic tool, the pinhole occluder is classified as a Class I by the FDA, subject to general controls but exempt from premarket notification. Manufacturing adheres to hygiene standards, with reusable models designed for sterilization via autoclaving or chemical wipes, and disposable variants available for single-use infection control. These devices are engineered for , with materials selected to prevent pinhole enlargement or loss of opacity over hundreds of clinical uses.

Types of occluders

Pinhole occluders are available in several variants designed to accommodate different clinical needs and patient demographics, with the single pinhole model serving as the foundational type. This basic design features a single central , typically 1.2 mm in , which allows for precise assessment of by restricting peripheral light rays. It remains the most commonly used form in routine eye examinations due to its simplicity and effectiveness in isolating central vision. Multiple pinhole occluders incorporate an of small holes, often ranging from 5 to 20 in a pattern, such as the 17-hole configuration found in standard handheld models. These variants enhance light transmission compared to single-hole designs, mitigating excessive dimming of while still minimizing refractive aberrations. They are particularly suited for scenarios where a single pinhole might reduce visibility too severely, such as in patients with larger pupils. Double-ended pinhole occluders provide versatility by combining a pinhole on one end with a solid opaque occluder on the other, typically measuring about 9.5 inches in length for easy handling. This design facilitates rapid switching between pinhole testing and complete eye occlusion, aiding in evaluations that require both functions sequentially. Pediatric and specialty occluders are adapted for younger patients or specific observational needs, often featuring smaller sizes, colorful handles, or animal-shaped exteriors to reduce anxiety during exams. Translucent or frosted versions, constructed from lightly diffused , allow clinicians to monitor eye movements under the occluder without fully blocking light, enhancing safety and accuracy in child assessments. These models are typically made from durable, non-toxic materials like . Advanced pinhole occluders integrate additional tools for multifaceted examinations, such as built-in rulers or compatibility with autorefractors for simultaneous measurements. Vinyl cupped designs, with a 60 mm concave rim, offer improved fit over eyeglasses or facial contours, preventing light leakage and ensuring stable positioning during testing.

Clinical applications

Visual acuity assessment

The pinhole occluder is utilized in visual acuity assessment through a standardized procedure where the patient holds the device over one eye to occlude the other, then views a chart such as the Snellen or symbols at 20 feet (6 meters). is first measured without the pinhole to establish the uncorrected baseline, followed by testing through the pinhole by aligning it centrally over the ; the patient may adjust slightly to find the clearest view, and the smallest readable line is recorded to quantify any change. This testing is repeated for both eyes, with patients instructed to keep both eyes open but cover the non-tested eye completely, avoid squinting or tilting the head, and report the clearest possible line without guessing. In clinical eye examinations, the pinhole occluder is integrated after initial uncorrected measurement, particularly if acuity is reduced (e.g., 20/40 or worse), to evaluate the contribution of before proceeding to or other tests. It serves as a quick intermediary step in refraction workflows, helping confirm the potential for best-corrected by simulating reduced optical aberrations, thus guiding whether further correction like is likely to yield improvement. For screening applications in school or community settings, the pinhole occluder enables rapid detection of uncorrectable vision loss by distinguishing refractive errors from other causes; if acuity improves through the pinhole, referral for is prioritized, while lack of improvement flags potential non-refractive issues requiring specialist evaluation. It is often combined with autorefraction devices for efficiency in large-scale screenings, enhancing throughput while minimizing false positives for correctable conditions. Expected outcomes from pinhole testing include an improvement of typically two or more lines on the acuity chart for cases of pure . This reflects the device's ability to approximate best-corrected potential with high correlation to final results (intraclass correlation coefficient of 0.97). In contrast, no improvement or a worsening of acuity suggests underlying pathologies unrelated to , such as media opacities or retinal issues, prompting further diagnostic investigation.

Differential diagnosis

The pinhole occluder serves as a key tool in by helping to differentiate refractive errors from non-refractive causes of reduced . When vision improves through the pinhole, it typically indicates uncorrected refractive issues such as , hyperopia, or , as the device reduces spherical and chromatic aberrations while increasing the . Conversely, lack of improvement suggests pathological conditions, including media opacities like cataracts, retinal disorders such as , or neural pathologies like , where structural damage prevents acuity gains despite optical correction. In specific conditions, the pinhole test yields variable results that aid diagnosis. For , partial improvement may occur if a refractive component is present, but full restoration is often limited by neural suppression, guiding clinicians toward occlusion therapy or further evaluation. In , the benefit is typically limited due to irregular and higher-order aberrations that the pinhole cannot fully mitigate, often prompting advanced imaging like . Post-cataract surgery, the test assesses residual refractive errors or potential acuity, helping to determine if vision deficits stem from uncorrected rather than surgical complications. Despite its utility, the pinhole occluder has diagnostic limitations, as it cannot quantify the type or magnitude of refractive errors, such as distinguishing spherical from cylindrical components, necessitating follow-up with objective methods like or . In pediatric examinations, it helps rule out congenital cataracts by showing no improvement in cases of dense opacities, directing toward surgical intervention. Among adults, it differentiates —a refractive loss of accommodation that often improves with pinhole—from early , where damage may yield minimal gains, signaling the need for tonometry and testing. Studies support its reliability, with for detecting refractive errors ranging from 76% to 90% and specificity exceeding 88% in community screenings, depending on improvement thresholds like ≥2 logMAR lines.

Advantages and limitations

Benefits in diagnosis

The pinhole occluder offers significant simplicity and cost-effectiveness in diagnostic settings, typically costing under $10 per unit and requiring no or complex maintenance, which makes it highly suitable for resource-limited environments such as rural clinics or field screenings in developing regions. Its , handheld design enhances portability, allowing easy transport and immediate use without specialized infrastructure, thereby facilitating vision assessments in areas with limited access to advanced optometric equipment. A key benefit lies in its ability to enable rapid during visual acuity evaluations, distinguishing between uncorrected refractive errors—often correctable with spectacles—and underlying pathological conditions that require specialist referral, such as to an ophthalmologist. This quick categorization reduces unnecessary referrals and streamlines patient management in busy or screening programs. As a non-invasive tool, the pinhole occluder poses no risk of side effects during brief diagnostic use, promoting high compliance and comfort in routine eye examinations across diverse clinical contexts. It enhances diagnostic accuracy by minimizing false positives in vision screenings through confirmation of the refractive component of reduced acuity, with studies indicating improved specificity, particularly in pediatric assessments where it helps segregate refractive errors from or other issues. The occluder's versatility extends its utility across all age groups, from modified versions for infants to standard use in adults and the elderly, and it readily integrates with digital vision charts in tele-optometry platforms to support remote diagnostics.

Drawbacks and contraindications

The pinhole occluder reduces the amount of light reaching the , which can diminish in low-illumination conditions or in patients with pre-existing low vision, as the restricted limits retinal levels. While designs with multiple holes can partially mitigate this effect by allowing more light entry, they do not fully eliminate the reduction in overall illumination. The pinhole occluder provides limited improvement in for certain conditions where the issue is not primarily correctable by reducing optical aberrations, such as irregular corneas in or central scotomas due to ; it is less effective for compared to spherical refractive errors. It can even worsen vision if the occluder is misaligned or decentered relative to the visual axis, leading to increased blur or ghosting, particularly in eyes with large pupils. Prolonged or improper use of the pinhole occluder during testing can induce , headaches, and a narrowed due to the restricted and reduced contrast sensitivity. Unlike pinhole glasses marketed for extended wear, the occluder is intended solely for short-term diagnostic purposes and is not suitable for therapeutic or habitual use. It is also less reliable in uncooperative patients, such as young children, who may struggle to maintain proper alignment, leading to inaccurate results without specialized pediatric adaptations. A single small in the occluder can introduce blur, degrading image quality and , especially if the is below 0.94 mm. Studies indicate accuracy limitations, with reduced in complex cases like pediatric screening or irregular , potentially resulting in missed diagnoses that necessitate further confirmatory tests.

History and development

Early origins

The pinhole effect was first observed in ancient times through natural phenomena, such as sunlight passing through small gaps in leaves to project inverted images during solar eclipses, as noted by the Greek philosopher in the 4th century BCE. described these projections in his writings on , recognizing how small apertures could form clear images without lenses, laying early groundwork for understanding light behavior through tiny holes. In the , the Arab scholar , also known as Alhazen, advanced this knowledge by systematically studying the of small apertures in his seminal work . He constructed the first known using a pinhole to demonstrate how light rays from an object pass through a small opening to create an inverted image on a surface, formalizing the principles of and that would influence later vision studies. During the early , and Jesuit Christoph Scheiner conducted pioneering experiments with pinholes to investigate eye and , detailed in his 1619 treatise Oculus, hoc est: Fundamentum opticae. Scheiner used a double-pinhole device, now known as the Scheiner disc, to observe how light focuses on the and to measure the eye's refractive state by dissecting animal eyes and projecting images through apertures, providing for the eye's . The saw the pinhole principle integrated into emerging vision tests and optical devices, evolving from photographic applications to rudimentary diagnostic tools. Scottish physicist described pinhole photography in his 1856 book The Stereoscope, proposing a lensless camera that used a small to capture sharp images, which highlighted the pinhole's ability to correct for optical aberrations and inspired its adaptation in eye examinations. By the late 1800s, opticians informally employed simple perforated cards or metal plates with tiny holes during trials to assess and improve by limiting peripheral light rays, predating standardized occluders. There was no single inventor of the pinhole occluder as a medical tool; rather, it emerged organically from these optical traditions, with early —featuring multiple perforations for vision —patented in the early , building on pre-20th-century informal uses by practitioners. This gradual transition marked the pinhole's shift from a scientific to a practical in vision correction, though formal standardization in occurred later.

Modern usage in ophthalmology

In the early 20th century, the pinhole occluder became a standardized tool in and for assessing during routine examinations, as documented in manuals and professional guidelines that emphasized its role in differentiating refractive errors from other visual impairments. This standardization marked a shift toward , making the device an essential, low-cost instrument in primary eye care settings. Mid-20th-century advancements addressed limitations like reduced light transmission in single-hole designs, leading to the adoption of multiple-hole pinhole occluders to enhance brightness while maintaining the stenopeic effect. Post-World War II, these tools were integrated into expanded pediatric and vision screening programs, enabling efficient detection of acuity deficits in children across initiatives. From the late into the 21st, research solidified its diagnostic value; for instance, a 1985 study demonstrated that pinhole screening reduced false-positive rates in assessments by over 50%, supporting its efficacy in community and clinical settings. It remains a core component of vision protocols for global eye health screening, particularly in resource-limited areas. In eye care training curricula worldwide, such as the International Core Curriculum for Ophthalmic Assistants, instruction on pinhole occluder use is mandatory for measuring potential acuity and ruling out refractive issues. As of 2025, while digital integrations like automated phoropters have modernized workflows, the pinhole occluder's core design persists due to its proven reliability.

References

  1. [1]
    A Peek at the Pinhole - Review of Optometry
    Mar 15, 2020 · A pinhole occluder is a tool with small apertures that improves visual acuity by blocking unfocused light, and is used to categorize reduced ...
  2. [2]
    Pinhole visual acuity - American Academy of Ophthalmology
    The pinhole is an eye shield with several small holes that allow light rays to reach the retina without the interference of optical problems of the eye.
  3. [3]
    Quantitative Analysis of Functional Changes Caused by Pinhole ...
    The single pinhole occluder is a simple device used by ophthalmologists and optometrists for diagnosis of refractive errors. Due to its easy handling and short ...
  4. [4]
    Pinhole Glasses: What They Are and Who They're Good For - WebMD
    Pinhole glasses, as the name implies, are glasses with tiny holes poked through their lenses. Whereas contact lenses and standard glasses redirect and focus ...
  5. [5]
    Pinhole Intraocular Lenses - EyeWiki
    Jun 11, 2025 · The pinhole affect is based on the stenopeic principle, which allows small central rays to enter the eye and eliminates diverging rays, ...
  6. [6]
    Matrix optics of artificial intraocular pinhole apertures in astigmatic ...
    May 31, 2023 · A pinhole aperture restricts a pencil of light to only the paraxial rays, making paraxial or first-order optics ideal for the study of pinholes.
  7. [7]
    [PDF] The effect of pinholes of different sizes on visual acuity under ...
    Many people experience an improvement in their visual acuity (VA) with pupil constriction in bright light conditions due to the pinhole effect. This implies.Missing: stenopeic | Show results with:stenopeic
  8. [8]
    Blur Unblurred—A Mini Tutorial - PMC - PubMed Central - NIH
    Apr 18, 2018 · Blur-Disk Diameter and Pupil Diameter​​ b = - p df f . b rad = pD . This is almost the desired equation except that the pupil diameter refers to ...
  9. [9]
    Applications of the pinhole effect in clinical vision science
    Jan 1, 2024 · Pinhole spectacles improve near visual acuity, but reduce reading speed, increase interblink interval, and decrease tear break-up time. For ...<|control11|><|separator|>
  10. [10]
    The potential of the pinhole as a visual aid in the developing world
    Aug 4, 2016 · For the adjusted scotopic measurements, the 1.5-mm-diameter pinhole also performed the best followed by the 1.2-mm-diameter and the 2.0-mm- ...
  11. [11]
    Single Pinhole Occluder - Premier Ophthalmic Services
    In stock $30.80 delivery- Length: This occluder is 25cm long. Product Benefits: - Optimal Eye Coverage: Our single pinhole occluders are specifically designed to cover one eye during ...Missing: specifications | Show results with:specifications
  12. [12]
    Single Pinhole Occluder - 1mm Black Vinyl Eye Testing Tool - Bernell
    4-day deliveryBlack cupped Single Pinhole Occluder with 1mm center opening--ideal for visual acuity and refractive testing. Made of durable vinyl, 60mm diameter, ...
  13. [13]
    Black Multi-Pinhole Occluder - OptiSource
    Free delivery over $149Lightweight with multi-pinholes · Features a pressureless 60 mm cup size · 2.25" total diameter · 9.5" long · Vinyl material.
  14. [14]
    Single Pinhole Occluder | Amcon Labs
    The Single Pinhole Occluder features a 1mm pinhole, 60mm vinyl cup, and 6 3/4" L handle for precise vision testing. Clean with antibacterial soap.Missing: details | Show results with:details<|control11|><|separator|>
  15. [15]
    [PDF] General Refraction Techniques
    The most useful pinhole diameter for clinical purposes is 1.2 millimeters. This size pinhole will be effective for refractive errors of +/- 5.00D. A pinhole ...Missing: occluder | Show results with:occluder
  16. [16]
  17. [17]
    Bringing Eye Care Devices to the US: Navigating FDA Regulations
    Apr 4, 2025 · Class I (Low Risk): Devices such as eye occluders & some surgical instruments. Many are exempt from 510(k) clearance but still require ...
  18. [18]
    Lorgnette Pinhole Occluder - Optics Incorporated
    In stock $18.50 deliveryThe convenient lorgnette-style handle makes it easy to switch between eyes, while the durable, easy-to-clean plastic construction ensures long-lasting use in ...Missing: materials | Show results with:materials
  19. [19]
  20. [20]
  21. [21]
    Parrot Fun Occluder Glasses - Pediatric Vision Testing with ... - Bernell
    4-day deliveryThese screening/testing occluder glasses are very colorful and are extremely durable! The new and improved occluder glasses now have adjustable temples for a ...
  22. [22]
    Occlud-A Measure Occluder - Amcon Labs
    The Occlud-A Measure Occluder performs eight essential vision measurements, including inter-pupillary distance and near point testing, in one affordable tool.Missing: advanced integrated
  23. [23]
    The 8-Point Eye Exam - American Academy of Ophthalmology
    May 24, 2016 · A pinhole occluder will also reduce the impact of uncorrected refractive error. If the patient is unable to see the biggest optotype on the ...
  24. [24]
    How to detect myopia in the eye clinic - PMC - PubMed Central - NIH
    May 13, 2019 · A pinhole occluder (an opaque disc with one or more small holes) is used to determine whether reduced vision is caused by refractive error. If ...
  25. [25]
    [PDF] Steps to checking vision using Snellen eye chart How to record ...
    Using a pinhole occluder​​ occluder back and forth until they find a hold that makes it look clearer for them. Then have the patient read the next clearest line ...
  26. [26]
    [PDF] Distance Visual Acuity - Moran CORE
    Testing Process: If pinhole vision testing is indicated, gently push the pinhole portion of the occluder in front of the patient's eye.
  27. [27]
    [PDF] The Eye Examination 1 - Renaissance School of Medicine
    If visual acuity is 20/40 or less in one or both eyes, repeat the test with the subject viewing the test chart through a pinhole occluder and record these ...
  28. [28]
    Visual Acuity - StatPearls - NCBI Bookshelf
    May 29, 2023 · This can then be used to test both eyes. Repeat with corrective lenses or pinhole occluder if necessary. Once completed, the visual acuity ...
  29. [29]
    Visual Acuity Testing Using Autorefraction or Pinhole Occluder as ...
    To compare visual acuity (VA) scores obtained after autorefraction or using a pinhole occluder to scores obtained after refraction according to a standard ...Missing: definition | Show results with:definition
  30. [30]
    [PDF] Using a Snellen Visual Acuity Chart Original Article Contributed by
    ... pinhole occluder can be used to help determine a possible etiology of decreased visual acuity. The occluder works by allowing light rays to enter the eye.
  31. [31]
    Accuracy of pinhole visual acuity at an urban Indian hospital - NIH
    Oct 19, 2018 · Pinhole acuity worse than 20/60 was 85.7% sensitive (95% CI: 59.1–100%) and 100% specific (98.0–100%) for detecting visual impairment not ...
  32. [32]
    [PDF] Screening for Impaired Visual Acuity in Older Adults - uspstf
    acuity is due to correctable refractive error (i.e., vision corrects or improves upon pinhole ... Community screening for visual impairment in older people.
  33. [33]
    Distance visual acuity
    Jan 9, 2017 · Improvement in vision with the pinhole usually indicates a refractive error or media opacity. Playing in picture-in-picture. (opens a new ...
  34. [34]
    Amblyopia - AAFP
    Feb 1, 2007 · Pinhole testing is useful in the primary care setting because it can help optimize vision. The child looks through a pinhole, using one eye at a ...
  35. [35]
    Keratoconus - EyeWiki
    Sep 29, 2025 · Measurement of pinhole visual acuity ... improve vision in some cases by changing corneal curvature and reducing irregular astigmatism ...Diagnosis · Physical Examination · Management · General Treatment
  36. [36]
  37. [37]
    [PDF] Role of Pin Hole in Rapid Recognition of Refractive Error as Cause ...
    Refractive error is one of the most common avoidable causes of diminished vision. This test signifies the importance of using pinhole as a quick assess tool to ...
  38. [38]
    Automated vision screening of children using a mobile graphic device
    May 5, 2021 · Without a pinhole, amblyopes are not segregated from those with only refractive error. In screening children having unknown refractive errors ...
  39. [39]
    3nethra specto - Forus Health
    Suitable for All Age Groups. Accommodates an interpupillary distance (IPD) ... Tele-Optometry Enabled. Seamlessly supports remote subjective refraction ...
  40. [40]
    Applications of the pinhole effect in clinical vision science - PubMed
    Jan 1, 2024 · Pinhole spectacles improve near visual acuity, but reduce reading speed, increase interblink interval, and decrease tear break-up time. For ...Missing: principle | Show results with:principle
  41. [41]
    Everything You Always Wanted To Know About...Pinhole Optics
    May 1, 2023 · It is used for presbyopia correction in the non-dominant eye in both phakic and pseudophakic patients. It is a 3.8 mm diameter, 6 microns thick ...Missing: definition | Show results with:definition
  42. [42]
    Pinhole does not increase screening accuracy of detecting ...
    Dec 2, 2021 · Pinhole does not increase the screening accuracy of detecting decreased BCVA in grade one primary schoolchildren. Visual acuity test using Lea Symbols is more ...
  43. [43]
    Results of the Pinhole Test Correlate with Hybrid Contact Lens ...
    Jun 24, 2022 · Pinhole occluders can improve VA by reducing retinal blur presented by narrowing the beam of light entering the eye [31, 32], cutting off ...
  44. [44]
    Pinhole history – AlternativePhotography.com
    Feb 7, 2010 · The philosopher Mo Ti recorded the formation of an inverted image with a pinhole. Aristotle wrote about pinhole images in the 4th century B.C. ...
  45. [45]
    The History of Camera Obscura and How It Was Used to Create Art
    Jul 21, 2024 · During the 4th century, Greek philosopher Aristotle noticed that sunlight passing through gaps between leaves projects an image of solar ...<|control11|><|separator|>
  46. [46]
    900 BC - AD 1399 - The History of The Discovery of Cinematography
    Aristotle observes crescent-shaped images created during an eclipse, through small holes in the leaves of trees, furniture and the crossing of the fingers.
  47. [47]
    Alhazen Builds the First Camera Obscura - History of Information
    Alhazen ·, built the first ; camera obscura · or pinhole camera—significant in the history of optics, photography, and the history of art.
  48. [48]
    Ibn Al-Haytham: Father of Modern Optics - PMC - PubMed Central
    He is known for the earliest use of the camera obscura and pinhole camera. As stated above, he contradicted Ptolemy's and Euclid's theory of vision that objects ...
  49. [49]
  50. [50]
    2.1 Optical principles for in-vivo assessment of LCA - Bio-protocol
    The Scheiner disc, named after Christoph Scheiner (1619), is a double pinhole aperture with the two pinholes separated away less than the pupil diameter.
  51. [51]
    [PDF] Seen through a Pinhole
    Scheiner used double pinholes to demonstrate for the first time the refractive state of the eye. Modern keratometers and autorefractor are built on this ...Missing: experiments | Show results with:experiments
  52. [52]
    The Pinhole Camera: A Simple Revelation - Reed Art & Imaging
    Apr 26, 2013 · ... David Brewster took the first known pinhole photograph. He is also believed to have coined the term “pin-hole” in his 1856 book, The Stereoscope ...
  53. [53]
    Sir David Brewster at Historic Camera
    Feb 24, 2012 · ... 1856. In it, he considered the possibilities of a camera with only a pinhole and without lenses. In his 1861 article, 'Upon Some ...
  54. [54]
    Vision Through Time: Ancient Solutions to Age-Old Sight Problems
    Apr 7, 2025 · Egyptian artisans crafted delicate copper plates with tiny pinhole perforations, an early version of pinhole glasses that helped sharpen blurry ...Missing: pre- 20th
  55. [55]
  56. [56]
    Device Product Classification Database - FDA
    This database includes: a list of all medical devices with their associated classifications, product codes, FDA Premarket Review organizations, ...
  57. [57]
    Effectiveness of a pinhole method for visual acuity screening - PubMed
    Use of the pinholes reduced the failure rate to 6.9%. Fifty-seven percent of those failing and 55% of controls had the clinic examination. Determination of best ...Missing: 1980s studies occluder
  58. [58]
    Visual acuity test, pinhole - MEDEVIS
    The patient changes the lenses and other settings while reading an eye chart to subjectively evaluate which settings give best vision.) The medical device term( ...
  59. [59]
    [PDF] International Core Curriculum on Refractive Error - Jcahpo
    Jan 3, 2011 · training programs for eye care professionals. Concurrently, the ... • Test and record visual acuity using the pinhole occluder.
  60. [60]
    [PDF] Article • Refraction in the Tele-Optometric Examination Compared to ...
    Visual acuity testing using autorefraction or pinhole occluder compared with a manual protocol refraction in individuals with diabetes. Ophthalmol 2011;118 ...
  61. [61]
    AI expanding in refractive surgery - EyeWorld
    EyeWorld spoke with several surgeons to learn more about how AI is impacting refractive surgery, as well as some other areas of the anterior segment.Missing: pinhole occluder assisted