Fact-checked by Grok 2 weeks ago

Rainscreen

A rainscreen is a type of exterior cladding in building construction designed to control rainwater penetration by incorporating an outer permeable screen that allows incidental entry while featuring an inner drainage plane—typically an air gap or —to channel moisture away from the structure's interior, thereby preventing to , framing, and interior finishes. This approach assumes that no outer layer can be perfectly watertight, especially under wind-driven , and instead relies on layered to reduce to negligible levels, often achieving up to 99.9% effectiveness in multi-layer assemblies. Rainscreen principles emerged in modern during the late as a response to failures in traditional barrier walls, with foundational research emphasizing the need for and to manage loads in diverse climates. Key components include the outer cladding (such as brick veneer, metal panels, or fiber cement boards), a ventilated or back-ventilated cavity (minimum 6 mm or 1/4 inch wide) for and pressure equalization, and an inner water-resistive barrier like or sheathing to serve as a secondary . Systems are classified into drained (relying on gravity and weep holes for water escape), back-ventilated (promoting airflow for drying), and pressure-equalized types, which compartmentalize cavities to minimize wind-induced differences and limit infiltration to less than 1% of incident . The adoption of rainscreens has become a in high-performance building envelopes, particularly in regions with heavy rainfall or high winds, as they enhance , reduce risk, and support energy-efficient designs through integration with continuous . Benefits include faster times for incidental , aesthetic versatility in facade materials, and lower long-term costs, though challenges like proper detailing at openings (e.g., windows) and higher initial costs—ranging from $20 to $150 per square foot depending on materials—require careful . Ongoing highlights the importance of prefabricated panels and subframing for , while gaps persist in long-term data across global climates.

Core Concepts

Definitions

A rainscreen is an exterior wall assembly consisting of an outer layer, an inner layer, and a between them designed to facilitate the passive removal of water and from the . This two-stage weather barrier approach positions the outer layer as the primary shield against , while the enables , , and limited equalization to manage any incidental moisture penetration. Key terms in rainscreen systems include cladding, the outer protective layer that forms the building's external finish and sheds most rainwater; drainage plane, the inner water-resistive barrier (WRB) that captures and directs any water entering the cavity toward intentional outlets; and ventilated cavity, the air gap between the cladding and drainage plane that promotes airflow, inhibits , and supports . Unlike single-skin walls, which rely on a monolithic layer for resistance and are prone to failure under wind-driven , rainscreens employ a multi-layered to enhance by separating the primary rain-shedding from secondary moisture control. In a basic schematic, this assembly layers the cladding outward, followed by the ventilated , and then the inward against the structural , forming a robust without direct contact between the outer and inner barriers.

Principles of Operation

A rainscreen system employs a two-stage protection mechanism to control water intrusion into building envelopes. The outer stage, provided by the cladding layer, acts as the primary barrier that deflects the majority of incident rainfall, screening bulk water through its surface and joints while minimizing direct exposure to the underlying assembly. Inevitably, a fraction of rainwater penetrates this layer due to factors such as wind pressure and cladding imperfections, but the design assumes this penetration is limited. The inner stage, comprising the drainage plane, serves as a secondary barrier that captures and manages this residual moisture through gravity-driven drainage to dedicated outlets and evaporation, preventing accumulation and potential damage to interior components. Ventilation within the air behind the cladding is to the system's functionality, enabling effective removal and . through vents at the top and bottom of the promotes convective by transporting away from wetted surfaces, including the back of the cladding and the drainage plane, which accelerates rates compared to unvented assemblies. This also mitigates differentials across the wall by allowing pressure buildup from internal to dissipate, thereby reducing the of inward and interstitial . Wind-induced pressure dynamics are addressed through the cavity's role in equalization or moderation, which substantially reduces water ingress at cladding joints. External wind creates pressure gradients across the facade, with elevated static pressure on windward surfaces driving rain into openings; the open cavity connects to the exterior via vents, enabling rapid pressure transmission that diminishes the differential acting on the cladding. This process leverages fluid dynamics, including Bernoulli's principle, where variations in air velocity over the building surface generate dynamic pressure differences that the cavity moderates to limit penetration forces. The air cavity further functions as a capillary break, countering surface tension-driven wicking of across narrow gaps. By maintaining a minimum width—typically 10 mm or greater—the cavity exceeds the capillary rise distance for (around 6 mm), preventing bridging between the infiltrated cladding and the drainage plane via adhesive forces. This physical separation ensures that any moisture transfer occurs primarily through larger droplets that drain freely rather than insidious flow.

Historical Development

Origins and Early Concepts

The principles underlying rainscreen systems have roots in ancient and , where builders employed simple strategies to shield structures from penetration. Overhanging , a common feature in , , and Asian buildings, directed rainwater away from walls, reducing direct exposure and allowing underlying surfaces to dry. In , particularly from the onward, log walls featured spaced timber cladding that created air gaps for , as seen in traditional stave churches like the (built circa 1130 but representative of ongoing practices). These designs promoted airflow to mitigate dampness without formal scientific validation. Pre-modern examples further illustrate early moisture management techniques. In , amado—sliding wooden rain screens—were used in traditional homes to protect interior panels from precipitation, forming a detachable outer layer that allowed when removed. Similarly, European half-timbered walls from the medieval period through the often incorporated panels with intentional air spaces behind or nogging, facilitating drying and preventing rot in timber frames. These approaches relied on empirical observation rather than engineered pressure equalization. In the , European architects advanced concepts in to enhance damp-proofing. Originating in and northwest in the late 19th century, these double-wythe walls with an air between leaves allowed moisture to drain and evaporate, addressing in urban settings. Architects such as those influenced by Regency-era designs promoted these for improved durability, laying groundwork for later ventilated systems. Early 20th-century experiments in built on these ideas, with ventilated facades emerging in and through research into timber cladding with drainage vents. Norwegian engineers refined open-jointed systems for barns and homes, emphasizing airflow to combat harsh climates. The term "rainscreen" was formally introduced in 1963 by Canadian building scientist G.K. Garden in his National Research Council publication, synthesizing these precedents into a principled framework for rain control. This conceptual foundation paved the way for broader adoption in modern building envelopes.

Evolution and Adoption

The mid-20th century marked key breakthroughs in rainscreen technology, with the Division of Building Research at the National Research Council of Canada publishing foundational work in 1963 on pressure-moderated walls in Canadian Building Digest No. 40. This research introduced the principle of pressure equalization to mitigate rain penetration by balancing air pressures across the cladding, laying the groundwork for modern ventilated systems. In the 1970s, European advancements formalized these concepts through research on ventilated facades. During the 1980s and 1990s, rainscreen systems saw widespread adoption in high-rise construction across and , driven by growing recognition of their role in preventing moisture-related failures in multi-story buildings. In , where principles were already established by the 1980s, integration became standard for energy-efficient facades; in , uptake accelerated in the 1990s amid stricter building codes. In the 21st century, particularly post-2010, rainscreen technology evolved with a focus on sustainability, earning credits in green building certifications such as LEED v4 for contributing to durable, high-performance envelopes that reduce lifecycle environmental impacts. Recent adaptations in the 2020s have emphasized climate resilience, with designs enhanced to withstand extreme weather events like intensified storms and flooding by improving drainage and pressure equalization features, including integration with net-zero energy standards in updated building codes such as the 2024 International Building Code.

System Components

Cladding Layer

The cladding layer serves as the outermost element in a rainscreen system, primarily functioning to shed rainwater, provide aesthetic appeal, and offer protection against (UV) radiation. By design, this layer must facilitate water runoff without significant absorption, acting as the initial barrier to bulk penetration while allowing incidental to drain away. Its aesthetic role enables diverse architectural expressions, from flat panels to textured finishes, enhancing building facades without compromising protective capabilities. Key design criteria for the cladding layer emphasize joint sizing and overlap configurations to optimize and minimize direct entry. Horizontal and vertical joints are typically sized at 6-10 mm to permit effective water shedding and airflow, preventing while maintaining structural integrity. Overlap arrangements, such as lapped seams or interlocking edges, further reduce water ingress by directing runoff away from vulnerable seams, often incorporating flashings or seals at interfaces. Attachment methods for the cladding layer rely on fixings to a supporting subframe, such as clips, rails, or Z-girts, which secure panels while preserving access to the underlying cavity. These fixings distribute loads evenly and accommodate movement, ensuring the layer remains stable without direct penetration of the inner wall assembly. Performance metrics for the cladding layer include resistance to wind loads as specified in ASCE 7 standards, which dictate design pressures for components and cladding based on building height, , and location to prevent detachment during extreme events. against is achieved through materials and configurations that withstand cycles of , , and UV , extending and reducing needs.

Drainage and Ventilation Plane

The drainage and ventilation plane in a rainscreen system serves as the inner barrier layer that captures any water infiltrating past the outer cladding, facilitates its removal through , and promotes drying via to protect the building structure. This plane is essential for managing incidental in wall assemblies, ensuring that water does not accumulate and cause to or structural elements. Compositionally, the drainage and ventilation plane typically consists of a weather-resistive barrier (WRB) installed over the sheathing, such as (e.g., or films), building paper (e.g., asphalt-saturated felt), or fluid-applied membranes that provide water repellency while allowing varying degrees of vapor permeability. Housewraps are often vapor permeable, exceeding 10 perms to support drying, whereas fluid-applied or sheet membranes may have lower permeability (0.1 to 10 perms) depending on the application. These materials are applied directly to wood, OSB, or sheathing to form a continuous layer that acts as the primary line of defense against bulk water entry. Drainage mechanisms within this plane rely on to direct downward and outward, often enhanced by vertical channels created by strips, dimpled mats, or profiles that form a minimum gap of 6 mm (1/4 inch) to prevent . For effective shedding, weep holes or open joints are incorporated at the base of the cavity, typically spaced every 600-900 mm, allowing accumulated to exit without ponding. Dimpled drainage mats, made of , provide textured surfaces that channel along predefined paths, ensuring even small volumes (as low as 1/16 inch gaps) can drain efficiently in systems like or siding applications. Ventilation paths are established through an behind the cladding, with depths commonly ranging from 10 to 25 (3/8 to 1 inch) to allow convective that removes vapor and promotes of both the cladding and the WRB. Open joints at the top and bottom of the cavity, often 10-20% of the wall's perimeter, enable air entry and exhaust, creating a chimney effect driven by and gradients. In reservoir claddings like brick veneer, a 20-25 cavity depth is recommended to support adequate without restricting . Integration of the and plane requires sealing around penetrations such as windows, doors, and utilities to maintain and prevent leakage paths, achieved through pan flashings, sill membranes, or compatible sealants that overlap the WRB by at least 150 mm. These details ensure the plane functions as a unified system, directing away from vulnerable junctions while complementing the outer cladding layer. Proper , including taped seams and lapped joints, is critical for the plane's performance across the entire assembly.

Pressure Equalization Features

In pressure-equalized rainscreen systems, the serves as a that facilitates rapid equalization between external wind and internal , thereby minimizing the across the cladding and reducing wind-driven . This mechanism operates by allowing air to flow through controlled openings in the cladding, balancing pressures such that the cavity pressure closely tracks external fluctuations, often achieving differentials below 50% of peak wind pressures in dynamic conditions and near-zero in static scenarios. Key design elements for effective pressure equalization include strategically placed openings at cladding joints, such as vent holes or gaps, which enable air exchange while limiting water entry; these openings typically comprise 1-2% of the wall area to ensure sufficient without compromising the rainscreen's integrity. Effective equalization requires the vent area to be at least 5-20 times the equivalent leakage area (ELA) of the air barrier, typically achieving 80-97% moderation in dynamic conditions. The air barrier must be highly airtight, with leakage typically limited to less than 0.2 L/(s·) at 75 , and the compartmentalized with rigid dividers to minimize fluctuations. For larger panels, the is often divided into compartmented chambers to contain equalization locally and prevent of across the entire facade, with recommended compartment sizes limited to approximately 1 or a maximum height of 6 m and width of 1.2 m at edges to optimize dynamic response. Testing for pressure equalization features focuses on verifying air leakage and overall system response. ASTM E283 measures the rate of air leakage through the assembly under specified differences (e.g., 1.57 or 75 ), ensuring the air barrier's effective leakage area (ELA) is controlled, typically targeting <0.12 cfm/ft² to support equalization without excessive inward flow. Field mock-up requirements, as outlined in standards like AAMA 508, involve constructing full-scale wall sections subjected to cyclic loading and spray to confirm equalization lag times below 0.08 seconds and maximum differentials under 50% of applied pressures, simulating real-world -driven exposure.

Design and Technical Considerations

Key Design Factors

Effective rainscreen design requires careful consideration of structural loads to ensure long-term integrity. The system must accommodate loads from of cladding panels, fasteners, and support brackets, as well as live loads such as pressures and potential snow accumulation, typically designed to meet or exceed requirements in the International Building Code (IBC). Thermal movements due to temperature fluctuations are also critical, particularly for metal claddings; for aluminum, the linear is \alpha = 23 \times 10^{-6} /^\circ \mathrm{C}, necessitating flexible joints and supports to prevent or cracking. These load factors influence the selection of subframing materials and attachment methods, ensuring the assembly transfers forces safely to the building structure without excessive deformation. Sizing guidelines for the rainscreen cavity and joints are essential for promoting drainage and ventilation. The cavity depth should be at least 10 mm (3/8 inch) for small panels to provide a capillary break and allow airflow, with deeper cavities—typically 25-50 mm—recommended for larger panels to facilitate gravity drainage and reduce moisture retention. Joint widths in the cladding layer are designed to control water entry while enabling venting; open horizontal joints of 8-12 mm, for instance, help achieve sufficient venting, often with perforated elements at inlets and outlets targeted at around 50% open area to support pressure equalization and air circulation behind the panels. These dimensions must balance aesthetic constraints with performance, adhering to standards like those from the Centre for Window and Cladding Technology (CWCT) for minimum ventilation paths. Integration with building systems emphasizes compatibility to maintain envelope performance. Rainscreen assemblies work alongside continuous exterior to minimize bridging, with the cavity positioned outward of the insulation layer to avoid restricting airflow or compromising the water-resistive barrier (WRB). The inner , including vapor barriers or retarders, must be sealed to control inward , ensuring the rainscreen's outer drainage complements rather than conflicts with these elements. Hygrothermal simulations, such as those performed with WUFI software, are used to model coupled and in these integrated assemblies, predicting behaviors under varying conditions to optimize insulation placement and barrier permeability. This approach verifies that the system supports overall without introducing unintended accumulation. Climate-specific adaptations adjust design parameters to local environmental demands, particularly in high-rainfall areas. Regions with annual exceeding 1000 mm benefit from rainscreens with increased cavity depths—often 38-50 mm or more—to enhance drainage capacity and drying rates, as recommended by guidelines like those from the Whole Building Design Guide. In such zones, wider joint openings or additional venting features further promote , adapting the system to intense wind-driven rain while maintaining structural stability. These modifications ensure robust performance without over-engineering for milder climates.

Moisture Management and Risks

In rainscreen systems, entrapped moisture can accumulate through mechanisms such as rise in narrow cavities and driven by vapor diffusion or air leakage. occurs when draws liquid upward or laterally through porous materials or tight gaps less than about 5 mm (3/16 inch), potentially bridging the air gap and wetting the inner water-resistive barrier if no adequate capillary break is provided. forms when warm, moist interior air contacts cooler surfaces within the wall assembly, particularly in climates with significant temperature differentials, exacerbating risks if drying is impeded. These sources are compounded by incidental water penetration from wind-driven , which the drainage plane must manage to prevent long-term accumulation. Risk assessment for moisture in rainscreens evaluates exposure levels and potential for damage, with higher risks in coastal or wind-prone areas where can result in penetration of approximately 1% of incident rainfall. Frameworks such as Standard 160 categorize assemblies based on potential versus capacity, identifying risk conditions where () exceeds 80% for more than four weeks annually as conducive to growth on susceptible materials like wood or . In such conditions, fungal growth can initiate at temperatures above 5°C, leading to biodeterioration, reduced structural integrity, and issues if unchecked. Mitigation strategies focus on enhancing , , and to minimize entrapment and promote drying. screens, typically made of fine like non-woven , are installed over vent openings to block pests while maintaining airflow rates of at least 5-10 () in the . Sloped sills at the base of the or interfaces, angled at 5-15 degrees, facilitate shedding and prevent that could lead to re-entrainment. Ongoing with hygrometers or sensors allows real-time assessment of conditions, enabling early detection of RH spikes above 80% and informed maintenance. Notable failure examples underscore the consequences of poor moisture management, such as the 1990s cladding issues in high-rises where undetected leaks from inadequate and contributed to ingress and in buildings investigated in early regulatory reviews. These incidents, often in exposed urban environments, highlighted how unmitigated and risks could degrade fixings and supports, prompting stricter building codes for .

Applications and Practices

Types and Materials

Rainscreen systems are primarily categorized into two main types based on their approach to managing infiltration and : drained and ventilated systems, and pressure-equalized systems. Drained and ventilated rainscreens, also known as drained/back-ventilated (D/BV) systems, feature an open behind the cladding that allows incidental to drain freely and promotes airflow for drying, typically through unsealed joints at the base and top of the wall. These are the most common type for modern applications due to their simplicity and effectiveness in moderate wind-driven conditions. Pressure-equalized rainscreens (PER), or compartmented systems, divide the into isolated chambers with sealed compartments and limited venting to equalize air between the exterior and the , minimizing driven by wind differences; this design is preferred for high-rise buildings in zones. Face-sealed systems, which rely on continuous seals around the cladding to block entry without a dedicated plane, are not considered true rainscreen applications as they lack ventilation and are prone to failure if seals degrade. Cladding materials for rainscreen systems are selected for their , , and compatibility with the principle, spanning metals, composites, and sustainable options. Metals such as aluminum and provide lightweight, corrosion-resistant exteriors; aluminum panels offer formability and a wide range of finishes, while develops a natural for low-maintenance longevity. Composites like fiber cement deliver a stone-like appearance with high impact resistance and are often through-colored for consistent weathering. Sustainable choices, including terracotta, emphasize ; these clay-based panels, made from natural materials, are recyclable and maintain thermal stability. Backing materials form the inner layers of the rainscreen assembly, supporting moisture control and structural integrity. Water-resistive barriers (WRBs) such as provide a breathable that sheds bulk water while allowing vapor to prevent interstitial condensation. Cavity fillers, including rigid boards with integrated channels, occupy the air gap to enhance thermal performance without impeding airflow; for instance, extruded or boards feature grooved surfaces to direct water downward. Material selection for rainscreen systems prioritizes performance criteria like fire resistance and long-term to ensure safety and cost-effectiveness over the building's lifespan. Fire ratings are critical, with assemblies often required to comply with NFPA 285 for evaluating flame spread and smoke development in noncombustible exterior walls; many cladding materials, such as , achieve Class A ratings per ASTM E84 for low flame spread (≤25) and smoke development (≤450), supporting whole-system NFPA 285 pass rates. favors materials with proven 50-year , balancing initial costs against minimal maintenance; for example, and terracotta panels demonstrate resistance to UV, freeze-thaw cycles, and biological growth, yielding lower total ownership costs compared to shorter-lived alternatives.

Installation, Standards, and Case Studies

Installation of rainscreen systems begins with preparing the substrate to ensure it is clean and suitable for receiving the weather-resistive barrier (WRB), following manufacturer guidelines. The WRB, such as building paper or peel-and-stick membrane, is then installed over the sheathing, with seams lapped a minimum of 2 inches horizontally and 12 inches vertically, and sealed using caulk or compatible to prevent air and infiltration. For optimal performance, the WRB installation must be inspected and tested for continuity before proceeding, as improper sealing can lead to moisture risks behind the cladding. Subframe erection follows, involving the attachment of pressure-treated strapping or strips to the studs at a maximum spacing of 16 inches on center using approved corrosion-resistant fasteners, maintaining a minimum 10 mm gap from the WRB. These strips provide the for the cladding and ensure the air cavity remains unobstructed for and . Cladding attachment sequencing typically starts at the base, using starter clips or J-trims secured to the subframe, followed by panels or boards fastened with stainless-steel screws at a 45-degree angle into grooves, progressing upward while aligning with chalk lines and allowing for . Bug screens are installed at openings to prevent insect entry, and end grains of cut panels are sealed with clear wax to mitigate moisture absorption. Rainscreen standards emphasize moisture management and performance verification. Internationally, ISO 15026 provides methods for numerical simulation of hygrothermal performance, specifying equations for non-steady heat and moisture transfer through building components to assess risks in wall assemblies. Regionally, the Roofing Contractors Association (NRCA) guidelines for low-slope roof systems recommend integrating rainscreen principles to ensure positive and compatibility with edges, avoiding ponding that could compromise the envelope. As of 2025, the European Union's revised Products Regulation (CPR), which entered into force on January 7, 2025, with most provisions applying from January 8, 2026, mandates Environmental Product Declarations (EPDs) for construction products like cladding, requiring digitized data on metrics under EN 15804 to facilitate compliance and reduce environmental impact. Case studies illustrate effective and problematic implementations of rainscreen systems. In contrast, the 2017 Grenfell Tower fire in highlighted critical failures in rainscreen application, where combustible aluminum composite material (ACM) panels and insulation enabled rapid fire spread due to inadequate compartmentalization and dishonest testing by manufacturers, resulting in 72 deaths and prompting global reforms in cladding . emphasized the need for robust cavity barriers and non-combustible materials to maintain compartmentation integrity. Maintenance of rainscreen systems involves periodic inspections to sustain performance, typically annually or biennially depending on environmental exposure. These checks focus on clearing blockages from or nests that could impede and , visually assessing cladding fasteners for , and verifying around penetrations to prevent moisture accumulation. Prompt repairs, such as re-sealing joints or replacing damaged panels, are essential to avoid long-term deterioration.

References

  1. [1]
    BSD-030: Rain Control Theory - buildingscience.com
    Aug 6, 2010 · A rainscreen system typically contains a drainage layer as the second layer of the assembly, (i.e. d2 ≈ 1.0).
  2. [2]
    [PDF] A Review of the State-of-the-Art of Rainscreen Cladding ...
    May 23, 2025 · Rainscreen cladding systems act as both a drainage layer and capillary break, providing essential separation between the outdoor climate ...
  3. [3]
    [PDF] RAiNA Technical Bulletin: Defining Rainscreen Wall Performance
    Aug 1, 2021 · A rainscreen is an exterior wall assembly with at least an outer cladding layer and a water-resistive barrier (WRB) inner layer, plus a cavity ...Missing: envelope | Show results with:envelope<|control11|><|separator|>
  4. [4]
    What is a rainscreen system - SFS USA
    A rainscreen is a system of products that removes water and vapor from a building's exterior, consisting of an outer layer, inner layer, and air space.Missing: definition | Show results with:definition
  5. [5]
    Rainscreen walls: An updated definition for today’s construction environment
    ### Summary of Rainscreen Walls Definition and Key Terms
  6. [6]
    Rainscreen Overview
    A rainscreen protects buildings from rain, snow, and ice, like a raincoat. It's a multi-layer system with an outer cladding layer as the primary barrier.
  7. [7]
    BSD-013: Rain Control in Buildings | buildingscience.com
    Aug 22, 2011 · Screened-drained walls assume some rainwater will penetrate the outer surface (hence the cladding “screens” rain) and remove this water by ...
  8. [8]
  9. [9]
    History of the Rainscreen Principle
    The rainscreen principle dates back to the Middle Ages, with early examples in Norwegian wood and stone architecture, including a church in Urnes, Norway, ...Missing: origins | Show results with:origins
  10. [10]
    Cavity Wall Construction History
    It evolved in the latter years of the nineteenth century and became common in dwellings in northern and western Britain in the early 1900s.
  11. [11]
    [PDF] Rain penetration and its control - NRC Publications Archive
    Rain Penetration and its Control. Originally published April 1963. G. K. Garden. Please note. This publication is a part of a discontinued series and is ...
  12. [12]
    History of Rainscreen Cladding
    Feb 10, 2023 · Norwegian engineers developed a technique consisting of using timber cladding, adopting closed joints, and having openings at both, top and bottom to allow for ...
  13. [13]
    [PDF] Pressure Equalization in Rainscreen Wall Systems
    Pressure equalization in rainscreen walls transfers outside air pressure to an air space behind cladding, minimizing pressure differences and rain penetration.Missing: Bernoulli | Show results with:Bernoulli
  14. [14]
    [PDF] Literature Review Report - Rainscreen Association in North America
    The curtainwall industry was an early adopter of the term rainscreen, and their explicit use of the rainscreen principle. American Architectural Manufacturers ...Missing: origins | Show results with:origins
  15. [15]
    System intelligence: The rise of rainscreen technology in building ...
    Aug 9, 2025 · By the 1980s, the principles of rainscreen cladding were well understood and widely used throughout Europe. As the science behind these systems ...
  16. [16]
    The Science Behind Why Rainscreen Facade Systems Work | AMS
    Rainscreen systems increase a building's resilience to extreme weather, offering protection against rain, wind, and temperature fluctuations and ensuring ...Missing: 2020s | Show results with:2020s
  17. [17]
    Facts and fictions of rain screen walls - NRC Publications Archive
    Pressure equalization across the exterior cladding of exterior walls is an important feature for the application of the rain screen principle which aims at ...Missing: 1965 moderated
  18. [18]
    ISO 13788:2012 - Hygrothermal performance of building ...
    In stock 2–5 day deliveryISO 13788:2012 gives simplified calculation methods for: The internal surface temperature of a building component or building element below which mould ...
  19. [19]
    BSD-105: Understanding Drainage Planes | buildingscience.com
    Oct 24, 2006 · Drainage planes are water repellent materials (building paper, house wrap, sheet membranes, etc) that are located behind the cladding and are designed and ...
  20. [20]
    [PDF] Building Science Digest 105 Understanding Drainage Planes
    Oct 24, 2006 · Flashings are integrated with drainage planes creating for all practical purposes a flashing for the entire assembly (Figure 2). A “screen” or “ ...
  21. [21]
    [PDF] Pressure Moderation and Rain Penetration Control - Keleher Architect
    Many researchers, designers, and builders consider Pressure-Equalised Rainscreens (PER) to be the state-of-the-art with respect to enclosure wall design†.
  22. [22]
    [PDF] Pressure Equalization in Rainscreen Wall Systems - AIVC
    Pressure equalization in rainscreen walls transfers outside air pressure to an air space behind cladding, minimizing pressure differences and controlling ...Missing: Bernoulli | Show results with:Bernoulli
  23. [23]
    Pressure Equalized versus Back Ventilated Rain Screen System
    Pressure Equalized Rainscreen System is a very design intensive product. They utilize compartmentalization to create a barrier against moisture.Missing: buffer | Show results with:buffer
  24. [24]
    [PDF] AAMA Pressure-Equalized Rain Screen(PER) Testing R&D
    Test Methods: The test specimen was evaluated in accordance with AAMA 508-07, Voluntary. Test Method and Specification for Pressure Equalized Rain Screen Wall ...
  25. [25]
    Retrofitting Exterior Wall Assemblies with Rainscreen Systems | IIBEC
    Mar 16, 2014 · dead and live loads is more than one and one third the nominal strength allowed in the. International Building Code for new buildings of ...
  26. [26]
    Linear Thermal Expansion Coefficients of Materials
    ### Summary of Linear Thermal Expansion Coefficients for Aluminum and Steel in Building Cladding
  27. [27]
    [PDF] Ventilated Facade Systems: Versatility, Creativity & Resiliency June ...
    Jun 28, 2023 · A rainscreen system creates a barrier between exterior elements and the building's structure, preventing water, snow, wind, and sunlight from ...
  28. [28]
    [PDF] WHITE PAPER - Understanding Rainscreen Wall Systems
    • Garden, G.K., “Rain Penetration and Its Control,” CBD40, National Research Council, Canada, 1963. Website: http://www.nrc.ca/. • Garden, G.K., “Joints ...
  29. [29]
    [PDF] construction details - EQUITONE
    The perforated angle should be less than 0.8mm in thickness where placed between EQUITONE and the support frame, and should have a minimum 50% open area. In ...<|separator|>
  30. [30]
  31. [31]
    Rainbarrier® Continuous Insulation System - Owens Corning
    Rainbarrier is continuous insulation for rainscreen and exterior walls, reducing thermal bridging, increasing R-value, and simplifying air/water barrier ...Rainbarrier® Continuous... · Why Rainbarrier® Mineral... · Project Spotlight
  32. [32]
    WUFI® Pro | WUFI (en)
    Dec 12, 2024 · WUFI® Pro determines the hygrothermal performance of building components under real climate conditions. This type of comprehensive dynamic ...
  33. [33]
    Modeling Enclosure Design in Above Grade Walls Technical Report
    Nov 18, 2015 · WUFI software is capable of modeling cladding ventilation, by introducing interior or exterior condition air into an airspace within the ...<|separator|>
  34. [34]
    Rainscreen 101: Essential Guide by Masonry Technology - MTIdry
    The Whole Building Design Guide recommends that rainscreens be incorporated in areas that receive 40” (1000 mm) of rain per year or more, but rainscreens ...
  35. [35]
    Should I Use Rainscreen Systems in My Climate? - Sto Corp.
    May 25, 2023 · To protect against increasingly severe weather events, the building community must provide adequate waterproofing components in all future new ...Missing: 2020s | Show results with:2020s
  36. [36]
    [PDF] RAINSCREEN TECHNOLOGY FOR RESIDENTIAL APPLICATIONS
    Rainscreen technology applies to residential walls, increasing durability and reducing moisture risks. It is recommended in areas with over 20" of annual ...
  37. [37]
    (PDF) Moisture in buildings
    ### Summary of Moisture in Buildings Sections
  38. [38]
    Moisture Management Strategies | WBDG
    The "Perfect Wall" is comprised of cladding (rainwater control layer), control layers (heat, air and moisture) and structure (dead and live load control system) ...
  39. [39]
    Damp Buildings - Damp Indoor Spaces and Health - NCBI Bookshelf
    Viitanen (1997) modeled the time factor in the development of fungi and found that at RH above 80% for several weeks or months, mold can grow in wood when the ...
  40. [40]
    Rainscreen Systems 101: What They Are, How They Work, and Key ...
    Jun 2, 2025 · Because local amendments vary, confirming cavity depth, ventilation, and flashing details is essential for compliance. Rainscreen System Details ...
  41. [41]
    [PDF] Monitoring of Double-Stud Wall Moisture Conditions in the Northeast
    Mar 1, 2015 · The deep cavity fill walls (double-stud and I-joist) showed higher risks of mold growth, especially on the north side. In addition, the drying ...
  42. [42]
    Special investigation: how the government missed the chance to ...
    Jun 13, 2021 · Combustible insulation would steadily become commonplace in high-rise cladding ... And the lines from these failures to what happened at Grenfell ...
  43. [43]
    Cladding: Panels failed fire tests 13 years before Grenfell - BBC
    Sep 16, 2021 · Leaked test results suggest the government and construction industry had early evidence of the dangers posed by cladding, 13 years before the ...
  44. [44]
    [PDF] WHITE PAPER - Understanding Rainscreen Wall Systems
    1. The rainscreen cavity depth should be in addition to the depth of exterior applied insulation material so the ventilation flow is not restricted. 5) D/BV ...
  45. [45]
    RR-0406: Face Sealed vs. Drainable EIFS | buildingscience.com
    Mar 15, 2004 · Drainable EIFS are significantly different from face-sealed or barrier systems in that by definition they have a provision for drainage.
  46. [46]
    Rainscreen Cladding Materials – Different Benefits - SFS USA
    Rainscreen cladding materials span a diverse range of textiles, from metal to porcelain, each bringing unique strengths.
  47. [47]
    Zinc Cladding Wall & Facade Systems - RHEINZINK
    RHEINZINK offers seam, panel, cassette, and profile zinc cladding systems, including classic angled seams, flat lock tiles, and corrugated/trapezoidal profiles.
  48. [48]
    Rainscreen Cladding Systems for Exterior Facades - ASI-SD.COM
    Many of our materials, such as aluminum and fiber cement, are recyclable and designed to improve energy efficiency by enhancing thermal performance, reducing ...Missing: zinc | Show results with:zinc
  49. [49]
    Terracotta Cladding - LOPO China
    Terracotta Rainscreen Cladding system is based on the principle of rain screen. ... The terracotta cladding can also be recycled and reused as a new exterior wall ...
  50. [50]
    WRB behind rigid foam and rain screen - is this risky?
    Jan 21, 2016 · We can have (from outside in) a rain screen, then rigid foam, then WRB. Rain will still get behind the foam. It will only be able to dry via diffusion. This ...
  51. [51]
    NFPA 285: ECO Systems are Non-combustible
    In general, the specifications are limited to a flame spread and smoke-developed value as defined for a Class A material in accordance with ASTM E84 (that is, a ...
  52. [52]
    High‑Performance Ventilated Fiber‑Cement Rainscreen Panels
    Durable material with 50+ years of longevity, resistance to extreme temperatures, and a ventilated facade system for enhanced durability. Low maintenance.Missing: lifecycle | Show results with:lifecycle
  53. [53]
    TerraClad Rainscreen Cladding - BuildingGreen
    Aug 2, 2007 · It is durable—TerraClad carries a 50-year-plus life expectancy, according to the manufacturer, and is engineered to survive freeze-thaw cycles.
  54. [54]
    Installing Rainscreen Assemblies - Metal Construction News
    Oct 31, 2016 · Ensure that the substrate is clean and properly prepared to receive the air/water barrier, in accordance with the manufacturer's guidelines. A ...Missing: subframe erection protocols
  55. [55]
    [PDF] A REFERENCE GUIDE OF TYPICAL RAINSCREEN WALL AND ...
    ALL VERTICAL LAPS TO BE 12" Min. AND STAGGERED. THE INSIDE OF THE FRAME IS TO BE SEALED TO THE. AIR/VAPOUR BARRIER (A.B & V.B.) ON ALL FOUR SIDES.
  56. [56]
    Complete Guide to Installing a Rainscreen - Alumtechbond Toronto
    Apr 15, 2021 · The first step is to prevent moisture intrusion with house wrap installation in which following the vapor barrier instruction is essential. The ...
  57. [57]
    Assessment of moisture transfer by numerical simulation SS-EN ...
    This standard specifies the equations to be used in a simulation method for calculating the non steady transfer of heat and moisture through building ...
  58. [58]
    Roofing Guidelines - National Roofing Contractors Association
    NRCA roofing manuals keep you up to date on roofing industry standards and building code requirements and provide you with installation and other guidance.Missing: rainscreen | Show results with:rainscreen
  59. [59]
    The Complete Guide to Construction Products Regulation and EU ...
    Aug 11, 2025 · To comply, EPDs must follow the EN 15804 standard and be digitized for inclusion in product registries. This streamlines reporting, simplifies ...Missing: rainscreen ISO 15026
  60. [60]
    Burj Khalifa - Dubai - Al Abbar Group
    The whole system was designed as a bespoke unitized system, tested to ... Rainscreen Cladding, Aluminium Composite Solid Panels & Mashrabiya · Standing ...
  61. [61]
    Prime Minister's statement on Grenfell Tower Inquiry final report
    Sep 4, 2024 · We only have to look at the fire in Dagenham last week. A building that was still in the process of having its cladding removed. So this must be ...
  62. [62]
    What is Rainscreen Cladding? Guide to Exterior Wall Protection
    Oct 28, 2024 · Inspections: Regular inspections of the cladding and the ventilated cavity can help ensure that there is no blockage, moisture buildup, or ...