Dilatometer

A dilatometer is a precision designed to measure the dimensional changes in materials, most commonly the linear —defined as the change in per unit with —in over a range of conditions. These measurements are essential for understanding material behavior under , with applications spanning , , and geotechnical testing. The core principle involves detecting minute expansions or contractions, often using mechanical push-rods, optical , or capacitive sensors to achieve resolutions down to sub-micrometer or even picometer scales. Dilatometers date back to the , with notable precision innovations in the early , such as the 1912 interferential design by Irwin G. Priest at the U.S. Bureau of Standards, which employed monochromatic light and fringes to quantify variations with high accuracy, typically 0.01–0.02 microns. Modern variants, including push-rod systems standardized by ASTM E228 for rigid solids from -180°C to 900°C, enable reliable determination of the coefficient of linear (α = ΔL / (L₀ ΔT)). Other types, like capacitive or fiber-optic dilatometers, extend capabilities to cryogenic temperatures (e.g., 4–300 K) and fragile samples, facilitating studies of phase transitions and in such as superconductors or ceramics. Beyond , dilatometers find use in diverse fields: in for evaluating material stability under extreme temperatures, as in NASA's cryogenic tests; in via flat-plate models (ASTM D6635) for in-situ soil modulus assessment; and in electrochemical research to track volume shifts during battery reactions. These instruments prioritize contactless or low-contact methods to minimize errors from friction or sample deformation, ensuring for design, , and scientific discovery.

Definition and Principles

Definition

A dilatometer is a scientific instrument designed to measure volume or linear dimensional changes in materials resulting from physical or chemical processes, such as thermal expansion. The primary purpose of a dilatometer is to quantify dilation—either expansion or contraction—of a sample under controlled conditions, enabling the determination of key material properties, including thermal expansion coefficients. Basic examples illustrate its foundational principles; for instance, a functions as a simple dilatometer by exploiting the consistent volumetric expansion of mercury with rising to track dimensional shifts. Another approach involves water-based methods, in which samples are submerged in to detect volume variations through liquid displacement, particularly useful for studying solids under moderate ranges. In contrast to thermometers, which indirectly infer temperature by observing the expansion of a calibrated liquid column, dilatometers focus on directly recording the extent of dimensional change itself across diverse environmental conditions.

Measurement Principles

Dilatometers quantify dimensional changes in materials primarily by measuring the relative change in length, \Delta L / L, or volume, \Delta V / V, as a function of temperature change, \Delta T, or other variables such as pressure. This core principle relies on detecting minute expansions or contractions under controlled conditions. In contact-based systems, a precise force is applied to the sample while monitoring displacement with high sensitivity, often on the order of nanometers; non-contact methods use optical or capacitive sensors to achieve similar precision without applied force. Such measurements are essential for determining how materials respond to thermal or mechanical stresses, enabling the calculation of expansion coefficients that characterize these behaviors. The linear coefficient, \alpha, is defined as the fractional change in per unit change and is given by the equation \alpha = \frac{1}{L_0} \frac{\Delta L}{\Delta T}, where L_0 is the original of the sample, \Delta L is the observed change in , and \Delta T is the change. For volumetric expansion, the coefficient \beta (also denoted as the cubic expansion coefficient) describes the relative volume change and is expressed as \beta = \frac{1}{V} \left( \frac{\partial V}{\partial T} \right)_{p,N}, where V is the original volume, \partial V / \partial T is the partial derivative of volume with respect to temperature at constant pressure p and number of moles N. These equations assume small changes and isotropic behavior, providing a linear approximation valid for many engineering applications. Accuracy in dilatometer measurements is influenced by several key factors, including sample geometry, which is typically rod-shaped for linear expansion studies to ensure uniform stress distribution and reliable contact with the sensing mechanism. Temperature control is critical, with furnaces capable of reaching up to 2800°C for high-temperature investigations and cryostats extending to as low as 4 K (-269°C) for low-temperature analysis, requiring precise gradients to avoid artifacts from uneven heating. Error sources such as sample inhomogeneity, which can lead to non-uniform expansion, and mechanical hysteresis in the instrument's components, causing path-dependent discrepancies during heating and cooling cycles, must be minimized through careful preparation and system design. General calibration of dilatometers involves using standard reference materials, such as fused silica (e.g., NIST SRM 739), which exhibits well-characterized low to establish baseline data and correct for instrumental offsets. This approach ensures to accepted values, with measurements of the standard repeated to account for any systematic drifts in the system.

History

Early Inventions

The origins of the dilatometer trace back to the early , when Petrus van Musschenbroek invented the first known device of this type in 1731. Described in his work Tentamina Physica Experimentalia, this apparatus, which he termed a , measured through the displacement of liquid in a glass tube containing the sample material immersed in a heated bath. The design relied on observing the rise or fall of the liquid level to quantify dimensional changes, making it a foundational tool for assessing material behavior under heat. By the mid-19th century, advancements shifted toward more precise optical methods. In the 1860s and 1870s, French physicist Hippolyte Fizeau developed an interferential dilatometer to study the of , employing reflected beams of monochromatic to detect minute length variations via fringes. German physicist later collaborated with Fizeau, refining the instrument into what became known as the Fizeau-Abbe dilatometer, which used similar optical principles for non-contact measurements of solids, particularly glasses and . This design marked a significant improvement in accuracy, enabling resolutions down to fractions of a micrometer without physical contact. These early dilatometers found initial use in , where compensating for was critical. Van Musschenbroek's supported clockmaking by allowing adjustments for metal component expansions in timepieces and aided through evaluations of material stability at elevated temperatures. The Fizeau-Abbe instrument, meanwhile, proved essential for fabrication, such as lenses and microscopes, by precisely characterizing expansion in to ensure alignment under varying conditions. Early designs, however, faced notable limitations. Van Musschenbroek's relied on liquids like or mercury for displacement, which introduced risks of leakage, , or chemical reactions with samples. All rudimentary apparatuses were sensitive to uneven temperature gradients across the setup, potentially skewing results, and lacked , requiring manual and heating that limited and high-temperature applications.

Modern Developments

In the 1930s, significant advancements in dilatometer design focused on improving accuracy through differential measurement techniques. Pierre Chevenard patented a differential recording dilatometer in 1930 (US Patent 1,766,775, filed 1926), which allowed for the simultaneous heating of a sample and a reference material, such as Pyros alloy, in an electric furnace to mechanically record the expansion differences via amplifying levers and a tripod mechanism. This innovation enabled precise comparison of thermal expansions, reducing errors from environmental variations and laying the groundwork for more reliable quantitative analysis. A key early 20th-century innovation was the 1912 interferential dilatometer designed by Irwin G. Priest at the U.S. Bureau of Standards. This instrument employed monochromatic light and interference fringes to measure length variations with high accuracy, achieving resolutions of 0.01–0.02 microns, and advanced non-contact optical techniques for thermal expansion studies. Following World War II, dilatometer technology shifted toward automation and electronic integration during the 1950s and 1960s, facilitating continuous recording of dilation curves. Companies like NETZSCH began developing specialized dilatometers in the early 1960s to measure thermal expansion in ceramics and metals, transitioning from manual to semi-automated systems with electronic transducers for real-time data capture. This era saw the incorporation of strain gauges and similar sensors, originally advanced post-1938, into instrumentation for enhanced sensitivity and automated plotting, supporting industrial applications in materials testing. A notable in 1975 was the flat-plate dilatometer by Silvano Marchetti, designed for in-situ testing, which revolutionized geotechnical assessments by providing direct measurements of and history through a thin blade probe with a pressurized . This device used a thin blade probe with a pressurized to provide direct measurements of and history, emphasizing practical field deployment over constraints. In the and , modern dilatometers incorporated digital interfaces, such as USB connectivity for seamless data logging and software-driven analysis, exemplified by systems like the Linseis L75 vertical dilatometer. High-pressure variants, capable of operating up to , emerged for studying material behavior under extreme conditions, as in the Gnomix pvT dilatometer used for polymers and fluids. Additionally, dilatometers, such as the TA Instruments DIL 805 series, advanced rapid studies in by combining inductive heating with controlled cooling rates to map transitions like to . The term "dilatometer" entered English usage around 1880–1885, derived from "dilate" combined with "-o-" and "-meter," reflecting its role in measuring expansion. By the , through ISO and ASTM norms, such as ASTM D6635 (first issued ) for flat-plate testing and ASTM E228 for linear , ensured consistent methodologies across global applications.

Types

Contact Dilatometers

Contact dilatometers measure through direct physical contact with the sample, typically employing or capacitive sensors to detect linear as changes. These instruments are widely used in for precise characterization of solids under controlled heating or cooling conditions. The push-rod dilatometer, also known as a connecting rod dilatometer, operates by pressing a or probe against one end of the sample, while the other end is fixed. As the sample expands or contracts, the translates the , which is measured using transducers such as strain gauges or linear variable differential transformers (LVDTs). This setup achieves resolutions down to micrometers, making it suitable for routine analysis of metals, ceramics, and composites. In contrast, the dilatometer utilizes a parallel-plate configuration where one plate is attached to the sample and moves with its expansion, altering the between the plates. Changes in are detected electronically with high , often resolving displacements as small as 10 picometers. This design is particularly advantageous for low-temperature applications, including cryogenic environments down to millikelvin ranges, due to its minimal and low heat leak. Contact dilatometers offer advantages such as the ability to apply significant force to ensure intimate with dense or hard samples, providing direct feedback on expansion behavior. They are commonly integrated into or vertical furnace configurations for in-situ measurements up to 1600°C or higher, depending on the material. However, these instruments are susceptible to errors from between the probe and sample surface, which can introduce in the . They are less suitable for fragile, porous, or soft materials that might deform under probe , and precise is essential to minimize such artifacts. For applications demanding even higher precision without mechanical interference, non-contact methods may be preferred over contact dilatometers.

Non-Contact Dilatometers

Non-contact dilatometers measure through techniques, avoiding physical interaction with the sample to prevent deformation or , particularly in high-resolution scenarios involving delicate materials. These instruments primarily rely on optical and interferometric methods, enabling precise tracking of dimensional changes without mechanical components. Optical dilatometers utilize video cameras or high-resolution (CCD) sensors to monitor sample edges or affixed markers during heating. The system captures real-time images or video sequences, comparing the sample's position against a reference material with known expansion properties to calculate linear changes. This approach achieves resolutions on the order of 1 µm accuracy and supports temperature ranges from up to 1700°C, depending on configuration. It is particularly non-destructive and suitable for irregular or fragile shapes, such as soft foils or powders, as no force is applied to the specimen. Laser dilatometers, offering even higher , employ a setup where a beam splits into two paths: one reflecting off the sample and the other off a fixed reference. fringes formed by recombining the beams allow absolute measurement with picometer-level , typically around 0.3 nm. This technique excels at detecting sub-micron expansions in thin films or crystalline materials, where minute changes are critical. Key advantages of non-contact dilatometers include the absence of mechanical wear on probes, making them ideal for extreme high-temperature environments up to 2000°C or reactive atmospheres where contact could cause . They also facilitate real-time visual monitoring, enhancing analysis of dynamic processes like phase transitions. However, these systems face limitations such as sensitivity to surface reflectivity variations, which can affect optical signal quality in non-uniform samples, and susceptibility to environmental vibrations that disrupt interferometric stability. Additionally, the incorporation of advanced and lasers results in higher acquisition and maintenance costs compared to contact-based alternatives.

Specialized Dilatometers

Specialized dilatometers are engineered for particular environmental challenges or dynamic processes, extending beyond standard laboratory measurements to in-situ or extreme-condition applications. These variants incorporate tailored designs to capture data on material behavior under stresses, rapid cycles, or elevated pressures, providing insights into geotechnical properties, kinetics, and high- simulations. The flat-plate dilatometer, also known as the dilatometer test (DMT), employs a blade-shaped probe with a flexible membrane inserted into using conventional equipment to assess in-situ lateral and . Developed by Silvano Marchetti in the 1980s, the device is pushed at a rate of 2 cm/s to the desired depth, where the membrane is inflated in stages to measure pressures corresponding to response, enabling derivation of parameters such as the constrained modulus for foundation design. This method is standardized under ASTM D6635, which outlines procedures for performing the test in fine-grained soils. Quenching dilatometers facilitate the study of phase transformations in metals, particularly steels, by integrating controlled heating and rapid cooling cycles within inert or controlled atmospheres. These instruments heat samples to austenitizing temperatures (e.g., 800–1200°C) followed by at rates up to 100°C/s to observe contractions or expansions indicative of , , or formation, aiding in the optimization of processes. For instance, the Linseis L78 series uses a pushrod to track dimensional changes during such cycles, revealing temperatures and essential for development. High-pressure or volume dilatometers measure material expansion under elevated hydrostatic pressures using piston-cylinder configurations, simulating conditions like deep-earth interiors or industrial polymer extrusion. These setups, such as the MIT-designed instrument, operate up to 300 MPa and -30°C to 90°C, employing a stepper-motor-driven and LVDT to detect changes as small as 2 × 10⁻⁶ cm³, applied to systems like bilayers for analysis. Advanced variants extend to ~2 GPa for geophysical studies, using a Zwick testing with an 8 mm bore to probe phases under subduction-like conditions, providing thermodynamic data on metastable states. For polymer processing, devices reach 100 MPa to evaluate under high and cooling, informing injection molding simulations. These specialized dilatometers offer advantages in deployment or extreme-condition fidelity, yielding direct data on stress history in soils or transformation under non-equilibrium cooling, which standard instruments cannot replicate. However, their limitations include reduced versatility for routine laboratory analyses and the need for site-specific or process-oriented to ensure accuracy.

Applications

Materials Characterization

Dilatometers are essential for characterizing the thermal expansion behavior of materials, enabling precise prediction of dimensional stability during processes. In metals and alloys, such as aluminum alloys and steels, dilatometry measures the coefficient of thermal expansion () across temperature ranges, identifying changes that could lead to warping or stress in components like turbine blades or automotive parts. For ceramics, the technique quantifies shrinkage, where volume reductions of up to 20% occur during firing, allowing manufacturers to adjust process parameters for consistent and shape retention in tiles or insulators. benefit from dilatometric assessment of linear (typically 5–10 × 10⁻⁶/K from 0–300°C) and softening points, critical for tempering applications in architectural panels to prevent thermal cracking. In composites and polymers, dilatometry reveals anisotropic expansion in fiber-reinforced materials or glass transition-induced changes, informing mold design and in and packaging industries. Phase transitions in materials are detected through characteristic dilation peaks or slope changes in expansion curves, providing key temperatures for process optimization. The glass transition temperature (Tg) is identified by a sudden increase in CTE, as seen in polymers and glasses where mechanical properties like Young's modulus drop sharply; this is vital for alloy fabrication to avoid brittleness in high-temperature components. Crystallization events manifest as contraction peaks during heating, helping refine compounds by pinpointing onset temperatures around 500–800°C to enhance resistance. Martensitic transformations in steels and , such as , produce rapid length changes (up to 0.5%) at cooling rates of 50–100°C/s, enabling precise control in heat treatments for improved and life. Sintering and densification studies rely on dilatometers to track volume reduction in powder-based materials, guiding advancements in additive manufacturing. In powder metallurgy, dilatometry monitors shrinkage during heating, with relative densities reaching 97% after cycles up to 635 minutes, as observed in Ti-6Al-4V where open-to-closed porosity transitions occur at ~92% density. For 3D-printed alloys like 18K 5N gold via binder jetting, in-situ measurements reveal anisotropic shrinkage of 15–20% starting at 450–500°C due to volume diffusion, alongside phase shifts like AuCu I to AuCu II, optimizing debinding and firing for dense, jewelry-grade parts. Similarly, in 316L stainless steel prints, dilatometry confirms densification mechanisms akin to traditional powder metallurgy, with shrinkage rates informing layer adhesion and final porosity below 5%. In , dilatometers measure the solid fat index (SFI) in oils and by quantifying expansion changes during , a standard for . As fats cool, solid phase formation causes volume contraction, monitored at temperatures like 10°C, 21°C, and 33.5°C per A.O.C.S. methods; SFI values of 10–20 indicate optimal spreadability in margarines and shortenings. This volumetric approach, though labor-intensive compared to NMR, remains a benchmark for in and production. Modern dilatometry integrates with continuous cooling transformation (CCT) and time-temperature-transformation (TTT) diagrams to optimize heat treatments. dilatometers simulate cooling rates from 0.1 to 200°C/s, mapping transformations like to ferrite (674–757°C) or (Ms ~356°C) in dual-phase steels, enabling tailored microstructures for automotive crash resistance. These diagrams, derived from data, predict phase fractions and hardness, reducing trial-and-error in and processes for high-strength low-alloy steels.

Geotechnical and Industrial Uses

In geotechnical engineering, the flat-plate dilatometer test (DMT) serves as an in-situ method to evaluate soil stiffness, undrained shear strength, and stress history by inserting a stainless steel blade with an expandable membrane into the ground and recording pressure responses at incremental depths. This test, developed by Silvano Marchetti in the late 1970s, operates across a wide range of soil types, from soft clays with undrained shear strengths as low as 2-4 kPa to very stiff soils exceeding 1000 kPa, yielding constrained moduli from 0.4 to 400 MPa. The resulting data enable precise predictions of soil settlements and lateral earth pressures, which are critical for foundation design in civil infrastructure projects such as bridges and high-rise buildings. Additionally, the seismic dilatometer test (SDMT), an extension of DMT incorporating shear wave velocity measurements, supports earthquake risk assessment by evaluating liquefaction potential in sandy soils through empirical correlations with material indices like the dilatometer lateral stress index. In industrial metallurgy, dilatometers are essential for monitoring and phase transformations during processes like , , and , helping to mitigate cracking risks from differential expansion in alloys. For instance, dilatometry simulates rapid cooling after to optimize microstructures in steels and , ensuring dimensional stability and preventing defects such as reheat cracking in weld zones. In manufacturing, dilatometric analysis of alloy tracks expansion during and cycles, informing process parameters to avoid residual stresses that could lead to component failure under operational loads. For building materials, dilatometers characterize the thermal behavior of and refractories under simulated service conditions, including exposure and cyclic loading, by quantifying expansion or contraction over temperature ranges up to 1600°C. In , this involves measuring dimensional changes during , , and cycling to predict performance in structures subjected to elevated temperatures, such as in tunnels or floors. For refractories, dilatometry reveals behavior and phase transitions under -like heating, aiding the design of linings for furnaces and kilns to withstand cyclic stresses without spalling or cracking. In processing, dilatometers assess expansion under high-pressure and high-shear conditions typical of and injection molding, enabling control of warpage and residual stresses in molded parts. Specialized dilatometers measure as a function of up to 100 MPa, to 300°C, and cooling rates exceeding 100°C/min, providing data to model melt flow and solidification for materials like in . This helps optimize processing parameters to minimize dimensional distortions in automotive and components. Dilatometry also plays a key role in across industries, with routine testing verifying compliance to standards like ASTM E831, which specifies for linear of solid plastics and metals over controlled temperature ranges. This ensures material consistency in production lines, such as confirming expansion coefficients for metal alloys in automotive forgings or plastics in consumer goods, thereby reducing defect rates and supporting for end-use applications.

Emerging and Other Applications

Dilatometers have found innovative applications in monitoring chemical reactions, particularly in tracking molar volume changes during polymerization and curing processes for adhesives and coatings. In thermosetting resins like epoxy, dilatometry measures shrinkage or expansion as cross-linking occurs, providing real-time data on reaction kinetics and final material density. For instance, volumetric dilatometry has been employed to quantify dimensional changes throughout the cure cycle of reactive polymers, revealing how buoyancy-based measurements capture subtle volume shifts that influence mechanical properties. This approach is crucial for optimizing formulations in high-performance coatings, where uncontrolled expansion can lead to defects. Advanced manufacturing processes, such as additive manufacturing, increasingly incorporate dilatometers to monitor layer dilation and behavior in 3D-printed components. In metal and 3D printing, dilatometry evaluates of printed parts to predict warping or residual stresses during post-processing, enabling precise control over microstructure evolution. This is particularly relevant for nanocomposites used in , where dilatometric data informs the integration of fillers to minimize anisotropic and enhance reliability. In , dilatometers study volume changes associated with expansion in regions, aiding in the assessment of geohazards like thermal contraction cracking. dilatometer relaxation tests measure and deformation in ice-rich , providing insights into long-term stability under thawing conditions. Similarly, for hydrate formation in applications, flat dilatometer tests characterize deformation in hydrate-bearing sediments, simulating pressure and temperature effects to optimize gas systems without instability.

References

  1. [1]
    E228 Standard Test Method for Linear Thermal Expansion of Solid ...
    Jan 9, 2023 · This test method covers the determination of the linear thermal expansion of rigid solid materials using push-rod dilatometers.
  2. [2]
    A high resolution dilatometer using optical fiber interferometer
    May 23, 2024 · Dilatometers measure the sample length L(T) as a function of temperature T, the variation ΔL = L(T) − L(T0) from its value at a reference ...
  3. [3]
    [PDF] A new interferential dilatometer
    This is, indeed, the essential feature of the method to be described, but it has apparently not met with much practical application heretofore.
  4. [4]
    Interferometric dilatometer for thermal expansion coefficient ...
    Feb 10, 2006 · We present a simple and inexpensive interferometric dilatometer for the measurement of the thermal expansion of materials in the 4–300 K range.
  5. [5]
    Measuring the Thermal Expansion Coefficient of Aerospace Materials
    Jun 24, 2007 · This slide presentation details the cryogenic dilatometer, which is used by JPL to measure the thermal expansion coefficient of materials ...
  6. [6]
    D6635 Standard Test Method for Performing the Flat Plate Dilatometer
    Aug 16, 2017 · This test method describes an in-situ penetration plus expansion test. The test is initiated by forcing the steel, flat plate, dilatometer blade, with its ...
  7. [7]
    DILATOMETER Definition & Meaning - Merriam-Webster
    an instrument for measuring thermal dilatation or expansion especially in determining coefficients of expansion of liquids or solids. dilatometric.
  8. [8]
    Dilatometry - an overview | ScienceDirect Topics
    Dilatometry is defined as a method that measures the volume variation of materials as a function of temperature change, often using a mercury-based dilatometer ...
  9. [9]
    Dilatometer (DIL) - NETZSCH Analyzing & Testing
    Dilatometry (DIL) is a precise method for measuring dimensional changes of materials during temperature changes, providing key material properties.
  10. [10]
    Dilatometer (DIL) - Thermal expansion measurement from - Linseis
    Dilatometers enable the exact determination of the thermal linear expansion of solids, powders or samples under defined temperature conditions.
  11. [11]
    [PDF] Volume dilatometry - NIST Technical Series Publications
    (0.00017, if mercury is used in Pyrex glass), i is the temperature of the bath in degrees centigrade,. iT is the temperature of the liquid in the emergent.
  12. [12]
    Coefficient of Thermal Expansion and How to Measure it - Thermtest
    Oct 30, 2019 · Dilatometers can also be used to calculate the coefficient of thermal expansion. To determine the coefficient, the volume of the material is ...Missing: principles | Show results with:principles
  13. [13]
    Linear Thermal Expansion: Formula, Coefficients & Calculator
    dl = L0 α (t1 - t0) (1). where. dl = change in object length (m, inches). L0 = initial length of object (m, inches). α = linear expansion coefficient (m/moC, in ...
  14. [14]
    [PDF] Dilatometry - LabWrench
    The maximum sample diameter for the standard sample holders is. 12 mm. A special fused silica sample holder is available for diameters up to 19 mm. DIL 402 C - ...
  15. [15]
    [PDF] Linseis Dilatometer - Vertical and Horizontal Analyzer
    Wide temperature range. -263°C to 2800°C. The LINSEIS Dilatometers can be equipped with up to three furnaces at the same time. A broad variety of different ...
  16. [16]
    A calibration method for measuring thermal expansions with a push ...
    Nov 6, 2001 · To verify the validity of the calibration method, measurements of LTECs for samples of fused silica (SRM 739) and a sample of a single crystal ...
  17. [17]
    Dilatometer: An essential clockmaker's tool during the 18th century!
    It was the Dutch physicist Petrus Van Musschenbroek (1692-1761) who first invented and described an apparatus of this type. In 1731 he called it a pyrometer, ...
  18. [18]
    Copy of Musschenbroek's Pyrometer (Dilatometer), 1700-1731.
    Copy of Musschenbroek's 1731 pyrometer: made in 1877 by Elkington and Co. of London from an earlier model made by Gallonde of Paris using drawings of ...Missing: Petrus van invention
  19. [19]
    US1766775A - Differential recording dilatometer - Google Patents
    The dilatometer, theobject of the present invention, which comprises a device ensuring the mechanical registering of the expansions, is derived from the ...Missing: Paul | Show results with:Paul<|separator|>
  20. [20]
    60 Years of NETZSCH-Gerätebau GmbH
    Sep 1, 2022 · The DILATOMETER – Past and Present. The development of our dilatometers (abbreviated DIL) dates back to the porcelain industry and thus to ...
  21. [21]
    Strain and microstrain units and the history of the gauge sensor
    The most popular alloys used for strain gauges are copper-nickel alloys and nickel-chromium alloys. In the mid-1950s, scientists at Bell Laboratories discovered ...
  22. [22]
    [PDF] Technical Guidance on Use of the Linseis Vertical Dilatometer L75
    The dilatometer requires a USB cable connection to the computer where the dilatometer data is collected. It is best to have the computer/monitor on a ...Missing: digital | Show results with:digital
  23. [23]
    Gnomix pvT High Pressure Dilatometer Details - DatapointLabs
    Dilatometry measures the change in volume of a specimen subjected to different temperatures and pressures. Operating Range. Pressure: 10 to 200 MPa
  24. [24]
    [PDF] QUENCHING DILATOMETRY - TA Instruments
    The transitions between different phases of steel are especially clear when measured by the DIL 805A Quenching. Dilatometer, and the temperatures at which they ...
  25. [25]
    DILATOMETER definition and meaning | Collins English Dictionary
    dilatometry. noun. Word origin. [1880–85; dilate + -o- + -meter]. Trends of. dilatometer. View usage for: All Years, Last 10 years, Last 50 years, Last 100 ...Missing: etymology 1880-1885
  26. [26]
    Optical dilatometer: Temperature range from -180°C to 2800°C
    Optical measuring system: Optical dilatometer equipped with a high-resolution camera and fully automated focus ; Temperature range: -100°C up to 500°C; RT up to ...
  27. [27]
    A high-stability non-contact dilatometer for low-amplitude ...
    Jul 26, 2016 · In this work a dilatometer for temperature modulated isothermal and non-isothermal measurements in the temperature range from room temperature ...Missing: affecting | Show results with:affecting<|control11|><|separator|>
  28. [28]
    [PDF] DILATOMETRY - TA Instruments
    The DIL 806 optical dilatometer is an innovative[1] and versatile instrument for thermal expansion and contraction measurements. Sample length is measured.Missing: limitations reflectivity vibrations
  29. [29]
    [PDF] CONTACTLESS THERMODILATOMETRY OF GLASS CULLET
    Optical dilatometry is a very useful non- destructive method for measuring samples of irregular shapes which allows this method to be used to measure the ...
  30. [30]
    [PDF] L 75 – Laser Dilatometer Helium-Cryo- Dilatometer - Intek Group
    Picometer. Laser Dilatometer. A Laser Dilatometer ... The measurement principle is based on a Michelson interferometer which eliminates all mechanical errors.
  31. [31]
    [PDF] LINSEIS Laser Dilatometer Pico - series 0,3nm - Gammadata
    LINSEIS Laser Dilatometer Pico - series 0,3nm. Technical specifications Laser Dilatometer. Range: 20mm. Resolution: +/- 1nm, (+/-0.3nm typical). Accuracy: +/- ...
  32. [32]
    Laser Interferometric Dilatometer Applicable to Temperature Range ...
    Aug 7, 2025 · A laser interferometric dilatometer has been developed for measuring the thermal expansion of high-temperature solids in the temperature range 1300 to 2000 K.
  33. [33]
    Contact vs. Non-Contact Measurement Systems | KEYENCE America
    Unlike contact measurement systems, non-contact measurement systems excel at dimensional measurements and profiling of fragile, soft, or elastic material that ...Missing: dilatometer | Show results with:dilatometer
  34. [34]
    [PDF] The Flat Dilatometer Test (DMT) - ISSMGE
    The in situ Flat Dilatometer Test (DMT) was developed in Italy in the late '70s (Marchetti 1980). Initially introduced in North America and Europe, it is ...
  35. [35]
    DMT | The Original Marchetti Flat Dilatomer
    A Flat Dilatometer test consists in advancing a blade into the ground with any common field machine. At each test depth, a circular steel membrane located ...
  36. [36]
    Norms & Specifications | Studio Marchetti
    ASTM D 6635-01 (2001, 2007, 2015) “Standard Test Method for Performing the Flat Plate Dilatometer”. Book of Standards, 15 pp. Eurocode 7 (1997)
  37. [37]
    Phase transitions with dilatometer - Linseis
    The Linseis L78 quenching dilatometer is commonly used to measure the phase transformation (austenite, ferrite, martensite, perlite, bainite, …) temperatures ...
  38. [38]
    None
    ### Summary of High-Pressure Dilatometer
  39. [39]
    [PDF] High-performance dilatometry under extreme conditions
    This high-performance dilatometry studies phase diagrams and metastable phases up to ~2 GPa and down to ~79 K, including amorphous and crystalline ice phases.
  40. [40]
    A Novel Dilatometer for PVT Measurements of Polymers at High ...
    Aug 7, 2025 · We developed a dilatometer to investigate the specific volume of polymers as a function of pressure (to 100 MPa), temperature (to 2607deg;C), ...Missing: earth | Show results with:earth
  41. [41]
  42. [42]
  43. [43]
  44. [44]
    [PDF] DILATOMETRY - TA Instruments
    The DIL 805L is a fully automated self-contained quenching dilatometer used to observe dimensional changes under extreme conditions of controlled heating and ...
  45. [45]
    Transformations in the Ti-6Al-4V Alloy Studied Using Dilatometry ...
    This paper presents the results of research on the kinetics of transformations in the two-phase (α + β) Ti-6Al-4V alloy.
  46. [46]
    Experimental investigation and modeling of densification during ...
    Aug 1, 2024 · In this study, both sinter dilatometry measurements and furnace sintering experiments are conducted to ensure a robust analysis of the ...
  47. [47]
    Sintering behaviour of 3D-printed 18K 5N gold alloy by binder jetting
    May 25, 2023 · In this study, a 18K 5N gold alloy powder was employed in the printing process. Different heat treatments and densification processes were employed to achieve ...
  48. [48]
    Sintering densification mechanism of binder jet 3D printing 316L ...
    The sintering theory and densification mechanism of BJ3DP316LSS exhibited similarities to those observed in traditional powder metallurgy. However, there ...
  49. [49]
    Dilatometry - an overview | ScienceDirect Topics
    The traditional quality control tool for estimating spreadability has been the solid fat index (SFI) using dilatometry to measure volume changes as solid ...
  50. [50]
  51. [51]
    Experimental Determination of Continuous Cooling Transformation ...
    Therefore, the aim of this paper is to report the results of the experimental determination of CCT diagrams for DP steels subjected to intercritical ...
  52. [52]
    Advantages the DMT Can Bring to Your Next Project - GRI
    Nov 3, 2015 · The Flat Plate Dilatometer test (DMT) can be used to investigate soil properties and has many applications in geotechnical engineering.
  53. [53]
    [PDF] An Overview of Seismic Dilatometer Test (SDMT) - IOSR Journal
    The Seismic Dilatometer Test (SDMT) is a powerful in-situ testing method that provides valuable geotechnical and seismic data for a variety of applications. ...
  54. [54]
    [PDF] Sand liquefiability assessment by Flat Dilatometer Test (DMT)
    ABSTRACT. The aims of this paper are: (1) To summarize the available knowledge on the use of the flat dilatometer test (DMT) for evaluating.
  55. [55]
    Dilatometer in Steel Testing: Key Tool for Thermal & Structural Analys
    May 22, 2025 · The dilatometer measures thermal expansion and phase transformations in steel, ensuring quality, performance, and structural integrity ...
  56. [56]
    Quenching Dilatometers - TA Instruments
    Quenching dilatometers are used to study phase transformations and microstructural changes in steel and metal alloys.Missing: modern 2000s- 2020s interfaces USB pressure
  57. [57]
    Transformations in the Ti-6Al-4V Alloy Studied Using Dilatometry ...
    Dec 21, 2024 · In the metallurgical industry, dilatometry is employed to analyze thermal processes, characterize phases, and optimize heat and thermo-chemical ...<|control11|><|separator|>
  58. [58]
    [PDF] Dilatometry – DIL 502 Expedis® Series
    Dilatometry is a precise analytical technique that measures dimensional changes in materials as a function of temperature and/or time. It provides.
  59. [59]
    [PDF] Dilatometer Series DIL 402 Expedis Classic - NET
    Interchangeable, made of fused silica and alumina, in two versions. ·Single system (one pushrod). ·System with two pushrods usable in dual or differential mode.
  60. [60]
  61. [61]
    On-line testing equipment of P–V–T properties of polymers based on ...
    This equipment is based on an injection molding machine (IMM), and it can be used to get P–V–T data of polymers directly with a special testing mold under ...
  62. [62]