Thermomechanical analysis

Thermomechanical analysis (TMA) is a technique that measures the dimensional changes of , liquids, or materials as a function of and/or time under a controlled mechanical . It applies a static to a sample via a probe and precisely records displacements using sensors like linear variable differential transformers (LVDTs), enabling the determination of properties such as the coefficient of (CTE) and (Tg). Standardized by methods including ASTM E831, ASTM D696, and ISO 11359, TMA provides insights into material behavior under with high resolution, often down to nanometers. The core principle of TMA involves subjecting a specimen to controlled heating or cooling rates while applying a defined load, typically ranging from 0.001 N to 4 N, to monitor , , or deformation. Measurement modes include for evaluation, for softening points, for fibers and films, for bulk materials, and (e.g., 3-point ) for composites. Instruments operate over wide ranges, from -150°C to 1600°C in advanced models, under various atmospheres such as inert, oxidizing, or vacuum conditions, ensuring versatility for different material classes. Unlike (DMA), which uses oscillatory forces to assess , TMA employs static loads for straightforward . TMA finds extensive applications in research, development, and across industries, particularly for polymers, elastomers, thermosets, composites, adhesives, ceramics, , and metals. It evaluates critical parameters like shrinkage forces in films, temperatures in plastics such as PVC, and moduli during treatment, aiding in the characterization of multilayer materials and curing processes. In , TMA supports the study of transitions and mechanical stability, with specimen preparation involving simple geometries like rods or powders to ensure accurate, reproducible results. Advanced variants, such as modulated TMA, separate overlapping effects for enhanced precision in complex analyses.

Fundamentals

Definition and Principles

Thermomechanical analysis (TMA) is a technique that measures the dimensional changes in materials as a function of , time, and applied load, enabling the determination of key thermal properties such as the coefficient of thermal expansion (CTE), (Tg), and softening points. By tracking variations in , , or thickness, TMA provides insights into how materials respond to stimuli under controlled conditions, which is particularly valuable for characterizing phase transitions and stability. The fundamental principles of TMA are rooted in thermoelasticity for reversible expansions and for time- and load-dependent deformations in like polymers. In thermoelastic behavior, the linear dimensional change is described by the equation \Delta L = \alpha L \Delta T where \Delta L is the change in length, \alpha is the coefficient of linear , L is the original length, and \Delta T is the temperature change; this relation quantifies the intrinsic expansion tendency of a . Viscoelastic effects become prominent under applied loads, where TMA captures , relaxation, or softening, revealing how molecular mobility influences dimensional stability beyond simple elastic responses. TMA applies to a wide scope of materials, including solids, liquids, pastes, and composites, and distinguishes between linear (one-dimensional), volumetric (three-dimensional), and anisotropic expansions, the latter being crucial for directionally dependent materials like fiber-reinforced composites. Unlike zero-load techniques such as , which measure unconstrained , TMA is essential for load-dependent behaviors, as it simulates real-world stresses to assess how external forces alter thermal responses and reveal viscoelastic contributions.

Historical Development

The roots of thermomechanical analysis (TMA) trace back to 19th-century studies of , particularly through dilatometry, a precursor technique that measured dimensional changes in materials under temperature variations. Swiss physicist Charles Édouard Guillaume advanced this field significantly in the late 1800s and early 1900s by developing precise dilatometers to investigate alloys with low coefficients, culminating in his discovery of in 1896 and earning him the in 1920 for contributions to precision metrology. These early efforts laid the groundwork for understanding coefficient of (CTE) in solids, initially driven by needs in instrumentation and standards. TMA as a distinct emerged in the mid-20th century, evolving from manual dilatometry and tests to incorporate controlled loads for measuring deformation in materials like . Initial applications to date to 1948, when V. Kargin and colleagues used -based methods to study dimensional stability and free volume changes during thermal cycling. The formalization of TMA occurred in the with the advent of commercial instruments, prompted by growing demands in for accurate data in composites used in and industries. introduced early dedicated TMA instruments in the late , enabling automated measurement of expansion, , and under static loads up to 1000°C. followed suit in the early 1970s with similar systems, marking the shift from manual probes to programmable setups that improved reproducibility for and composite characterization. Post-1970s advancements accelerated with and integration, transitioning TMA from analog to for enhanced and . By the , computerized TMA systems became standard, allowing of deformation curves and with other techniques like , driven by needs for precise property evaluation in high-performance materials. In the , innovations focused on nanoscale resolution and extreme conditions, with probes achieving sub-micrometer sensitivity for local mapping in thin films and , as seen in techniques like introduced around 2009. High-temperature capabilities also expanded, with instruments supporting measurements up to 1600°C for ceramics and refractories in applications, reflecting ongoing evolution toward multifunctional, high-resolution systems.

Instrumentation and Setup

Key Components

A thermomechanical analysis (TMA) instrument consists of several core hardware components designed to measure dimensional changes in materials under controlled temperature and mechanical conditions. The sample holder, typically constructed from quartz or ceramic materials with low coefficients of linear thermal expansion (CLTE), such as approximately 0.55 × 10^{-6} K^{-1} for fused quartz, supports the specimen and minimizes measurement artifacts from the holder's own expansion. The linear variable differential transformer (LVDT) serves as the primary displacement sensor, offering sub-nanometer resolution (less than 0.5 nm) to detect minute changes in sample length or thickness. A surrounding furnace provides precise temperature control, achieving accuracy within ±1°C across wide ranges from -150°C to 1000°C, often monitored by a thermocouple positioned near the sample for reliable feedback. The force applicator, usually a motorized system, exerts programmable loads ranging from 0.001 N to 2 N with a resolution of 0.001 N, enabling both static and dynamic testing modes. Probe types are to adapting the for specific geometries and adapt to the material's behavior. Macro-expansion probes, with diameters of 6 mm, facilitate bulk under low loads (10–30 mN) for determining CLTE. probes, typically 1 mm in diameter, apply targeted force (e.g., 0.098 N) to assess softening or points. or probes, including three-prong setups for , evaluate responses like , while tension probes handle thin samples (20–200 μm thick) for studies. To maintain sample integrity, especially for oxidation-sensitive materials, an purge (e.g., at 20–50 mL/min) is employed, creating a with around the sample. Software integration enhances the instrument's functionality by enabling automated control and analysis. Data acquisition systems, such as Advantage™ or STARe™ software, capture real-time displacement data to plot strain \varepsilon versus temperature T, denoted as \varepsilon(T), while interfacing with temperature controllers to set ramp rates from 0.1 to 50°C/min. These platforms support customizable protocols for immediate visualization and post-processing of thermomechanical properties. Safety features are essential for reliable operation, particularly with reactive or high-temperature samples. Overload protection mechanisms limit applied forces to prevent damage, while compatibility with vacuum environments or reactive gas flows accommodates sensitive materials without compromising the system's integrity.

Calibration Procedures

of thermomechanical analysis (TMA) instruments is essential to ensure precise measurements of , , and force, minimizing systematic errors in determining coefficients of (CTE) and other thermomechanical properties. Procedures typically involve verifying each subsystem against and standards, with adjustments made to align instrument responses to known values. Temperature calibration establishes the accuracy of the furnace and sensor systems, often using phase transition standards to correct offsets. Certified materials such as , with a of 156.6°C, or , with a of 29.76°C, are heated in the , and the observed onset is compared to the certified value to determine any offset, which is then applied to the scale. verification involves cross-checking against a secondary standard, such as a resistance thermometer, to confirm uniformity across the range of interest, typically from -50°C to 1500°C depending on the . At least two calibration points are recommended to cover the operational range, ensuring for intermediate temperatures. Displacement calibration focuses on the (LVDT) or equivalent sensor, using reference materials with well-characterized values to scale the dimension change output. Standards like fused silica, with a known of approximately 0.5 × 10^{-6} ^{-1}, or alumina are run over a range 20°C below to 20°C above the intended interval, under a light force of 0.001 N to 0.05 N, to compute the instrument's cell constant as the ratio of the reference to the experimentally observed value. Zero-point adjustment is performed via an empty run, where the probe is equilibrated without a sample to set the baseline displacement at ambient conditions, correcting for mechanical slack or thermal drift in the setup. Force calibration verifies the load application system, particularly the , by applying known weights and adjusting for any deviations in the force sensor response. Brass or certified weights, such as 50 g equivalents (approximately 0.49 N), are placed on the or sample stage, and the displayed is tuned to match the gravitational load, ensuring accuracy across the typical of 0.001 N to 1 N used in TMA experiments. Compliance correction accounts for elastic deformation in the probe-sample interface by conducting initialization runs that measure the probe's inherent flexibility under zero load, subtracting this contribution from subsequent measurements to isolate true sample response. Guidelines for TMA calibration are outlined in standards such as ASTM E831, which specifies procedures for linear measurements including reference material runs for system verification, and ISO 11359, which details apparatus using multiple standards for and dimension accuracy. Recalibration is recommended at regular intervals, such as quarterly in high-use laboratories, or after instrument maintenance to maintain precision within 5% for CTE determinations.

Measurement Techniques

Penetration Mode

In penetration mode of thermomechanical analysis (TMA), a probe applies a constant mechanical force to the surface of a sample while the temperature is linearly ramped, allowing measurement of the probe's penetration depth to characterize material softening, glass transition, and related transitions. The probe, often with a diameter of approximately 1 mm and an extended or hemispherical tip, focuses the force on a small contact area to detect localized deformation, typically under loads ranging from 0.1 N to 10 N. This technique is particularly suited for determining the Vicat softening point, defined as the temperature at which the probe penetrates a depth of 1 mm into the sample under a specified load, such as 10 N for a 1 mm² contact area. Key parameters include temperature ramp rates of 1–10 °C/min, commonly 5 °C/min, to ensure controlled heating and accurate transition detection, with samples prepared as solid disks or cubes 5–10 mm thick to provide uniform contact and minimize . is recorded using high-resolution transducers, such as linear variable differential transformers (LVDTs), achieving resolutions down to 0.125 nm, which enables precise tracking of deformation as low as tens of micrometers during softening events. This mode offers advantages for analyzing amorphous polymers, where it provides high sensitivity to the temperature () through abrupt changes in penetration rate and to melt via the extent of deformation under sustained . It excels in evaluating thin films, coatings, or bulk solids without sample removal, yielding reproducible results at moderate heating rates. However, limitations include susceptibility to surface irregularities that can skew initial contact and non-uniform stress distribution across the probe-sample interface, potentially leading to inconsistent penetration in heterogeneous or filled materials. The penetration rate d can be approximated by the relation d = \frac{F / A}{\eta(T)}, where F is the applied force, A is the probe contact area, and \eta(T) is the temperature-dependent viscosity, providing insight into viscous flow during softening.

Expansion Mode

In expansion mode, thermomechanical analysis (TMA) measures the unconstrained dimensional changes of a material as a function of temperature, allowing the sample to expand or contract freely without significant mechanical loading. The typical sample is a bar or rod, 10–50 mm in length, placed between parallel supports or on a sample holder, with length variations tracked using a linear variable differential transformer (LVDT) that detects displacements as small as micrometers. This setup ensures minimal interference from external forces, capturing intrinsic thermal responses over a wide temperature range from cryogenic conditions (down to -150°C) to high temperatures up to 1600°C, depending on the instrument's furnace and probe materials. The primary metric derived from expansion mode data is the linear coefficient of thermal expansion (), denoted as α, which quantifies the relative length change per unit temperature increase and is calculated as α = (1/L) (dL/dT), where L is the reference length and dL/dT is the slope of the length-temperature curve. To obtain accurate values, especially in regions of non-linear , α is often determined via a least-squares linear fit applied to ΔL versus T data over defined temperature intervals, following standards such as ISO 11359-2 or ASTM E831. Contact forces between the probe and sample are kept very low, typically below 0.1 mN (or 0.001 N in advanced systems), to avoid compressive artifacts that could distort the expansion measurements. This mode is particularly useful for identifying phase transitions in materials, such as the β-relaxation in polymers, where subtle changes in expansion rate reveal secondary molecular motions below the temperature. For example, in amorphous polymers, the onset of β-relaxation may appear as a deviation in the CTE curve, providing insights into chain dynamics without requiring applied .

Flexure Mode

In the flexure mode of thermomechanical analysis (TMA), the sample is supported at both ends in a three-point configuration, typically with a span length of 17–26 mm, and a controlled force is applied at the center to induce bending while the deflection δ is measured as a function of δ(T). This setup allows for the of response under thermal stress, providing data on how the material deforms under load during heating or cooling cycles. The underlying principles rely on classical beam theory for a three-point bending configuration, where the maximum deflection at the center is given by \delta = \frac{F L^3}{48 E I} with F as the applied force, L the beam span length, E the elastic modulus, and I the second moment of area (moment of inertia) of the cross-section. By monitoring the temperature-dependent deflection under constant load, the modulus E(T) can be determined, revealing effects such as thermal softening, glass transitions, or phase changes that alter stiffness. For rectangular cross-sections common in TMA samples, I = \frac{b h^3}{12} (where b is width and h is thickness), enabling straightforward computation of E from measured \delta, F, L, b, and h. This mode is particularly suitable for characterizing thin films, laminates, or composite materials, where it can highlight mechanical in layered structures through responses along different orientations. Static loads in flexure mode typically range from 1 to 100 to avoid sample while ensuring measurable deflections, with optional low-amplitude dynamic oscillations for enhanced , though these differ from the full oscillatory protocols in dynamic TMA variants. Deflection is precisely tracked using high-resolution transducers, such as linear variable transformers (LVDTs) with sub-micrometer , allowing detection of subtle thermal-mechanical transitions. Applications often include of temperatures under load, as standardized in ASTM E2092 for three-point setups.

Torsion Mode

In torsion mode of thermomechanical analysis, the sample is securely gripped at both ends within specialized fixtures, and a controlled is applied to induce rotational deformation, measuring the resulting twist θ as a of T. Typical values range from 10 μN·m to 10 mN·m, depending on the instrument and sample size, with the twist detected via an optical encoder for high-resolution monitoring of . This setup enables the evaluation of shear-related responses in materials under thermal cycling, distinct from linear deformation modes. The primary analysis derives the G from the torsional response using the relation G = \frac{T L}{J \theta}, where T is the applied , L is the sample , J is the polar moment of inertia of the cross-section, and \theta is the measured twist angle in radians. This computation quantifies the material's resistance to and highlights variations due to fiber orientation in composites, where anisotropic behavior reflects directional . Torsion mode offers advantages in its sensitivity to molecular in polymers, allowing detection of subtle orientational effects on properties during transitions. It is also particularly useful for biomaterials, where assessing torsional compliance aids in characterizing mimics or fiber-reinforced constructs. Challenges include the requirement for precise sample to prevent slippage or uneven distribution, and applicability is generally restricted to cylindrical or rectangular geometries that permit uniform gripping and transmission.

Experimental Variants

Static Force TMA

Static force thermomechanical analysis (TMA) involves applying a constant mechanical load to a sample while subjecting it to a controlled program, typically a linear ramp, to measure dimensional changes and derive mechanical properties as a function of . The employs a fixed , commonly in the of 0.05 to 1 N, delivered via a precision force motor or weights, ensuring the sample remains within its linear viscoelastic response. During the experiment, the sample's deformation, such as extension or , is recorded using a high-resolution , like a (LVDT), with sensitivities down to 15 nm. This setup allows for the of J(T) = \frac{\epsilon}{\sigma}, where \epsilon is the strain (calculated from and sample dimensions) and \sigma is the constant stress ( divided by cross-sectional area). Sample preparation for static force TMA emphasizes uniform geometry and secure fixturing to minimize artifacts. Thin films or fibers, typically 10-26 mm in length and 0.1-1 mm thick, are clamped between parallel supports or gripped in tension mode, with care taken to avoid initial slack or excessive preload that could introduce nonlinearity. The measurement atmosphere is controlled, often using inert to prevent oxidation or air for ambient simulations, with purge flows of 50-100 mL/min to maintain thermal uniformity. Probes, such as flat-tipped for or knife-edged for , are positioned to apply the load perpendicularly, ensuring full contact without . The resulting data from static force TMA exhibit distinct features corresponding to material transitions, manifesting as step-like changes in or . In the sub-T_g region, remains low and relatively constant, reflecting the glassy state's rigidity. At the glass transition temperature T_g, a sharp increase in occurs due to enhanced chain mobility, often spanning 10-20°C. Further heating reveals additional steps at the melting temperature T_m for semicrystalline polymers, where rises dramatically as the softens or liquefies, enabling differentiation of these events from expansion alone. These signatures provide steady-state responses under constant load, contrasting with zero-force dilatometry. Analysis of static force TMA data begins with calculating the compliance J(T) from measured under the known , followed by deriving the apparent modulus E(T) = \frac{1}{J(T)}, which quantifies evolution. This modulus-temperature curve highlights transition onsets, such as the T_g from the inflection point in E(T). Error sources, including thermal lag from finite heating rates (e.g., 5°C/min), can shift transition temperatures by 2-5°C and are corrected using empirical methods like rate-dependent curves or multiple-scan comparisons to align with true values. Such corrections ensure accurate assignment of transitions without overcomplicating the steady-state focus.

Dynamic Force TMA

Dynamic force thermomechanical analysis (df-TMA), also known as dynamic TMA (DTMA), applies an oscillating load to a sample during a controlled temperature scan to probe its viscoelastic response. The procedure involves imposing a sinusoidal force of the form F = F_0 \sin(\omega t), where F_0 is the force amplitude and \omega is the angular frequency, typically at frequencies ranging from 0.01 to 2 Hz. The resulting strain is measured, along with the phase lag \delta between the applied force and the sample's dimensional response, enabling the calculation of the loss tangent as \tan \delta = E'' / E', where E' is the storage modulus and E'' is the loss modulus. This technique offers key advantages over static methods by resolving overlapping thermal transitions that may be obscured in conventional scans, as the dynamic loading separates reversible elastic deformation from irreversible viscous flow. It yields plots of storage modulus E' (representing elastic energy storage) and loss modulus E'' (representing energy dissipation) as functions of temperature, providing deeper insights into material and across transition regions. The setup for df-TMA integrates force oscillation capabilities into a standard TMA instrument, often resembling (DMA) systems for enhanced precision in viscoelastic measurements. Applicable sample geometries include those used in , , or three-point modes, such as films, fibers, or small bars, with force ranges typically from 0.001 to 2 N to ensure small-amplitude deformations that remain within the linear viscoelastic regime. In data interpretation, the peak in \tan \delta signals the glass transition temperature T_g, where molecular mobility increases and is maximized. Frequency dependence of the transition is analyzed to estimate relaxation times via \tau = 1 / \omega, with higher frequencies shifting T_g to elevated temperatures due to time-scale effects on chain dynamics. The E^* = \sigma_0 / \epsilon_0 (where \sigma_0 and \epsilon_0 are and amplitudes) decomposes into E' = E^* \cos \delta and E'' = E^* \sin \delta, facilitating quantitative assessment of temperature-dependent .

Modulated Temperature TMA

Modulated temperature thermomechanical analysis (MT-TMA) is a variant of thermomechanical analysis that superimposes a sinusoidal on an underlying linear heating or cooling program to separate reversible and non-reversible dimensional changes in a material sample. This technique enables the of effects from kinetic processes such as , curing, or shrinkage, providing enhanced insights into time- and temperature-dependent behaviors under controlled mechanical load. The procedure involves programming the temperature as T(t) = T_0 + q t + A \sin([\omega](/page/Omega) t), where T_0 is the initial , q is the underlying ramp rate (typically 1–2 °C/min), A is the amplitude (often ±1 to ±5 °C), and \omega = 2\pi / P with P as the modulation period (usually 100–300 s to account for instrument thermal lag). A sample, such as a film or composite, is subjected to a constant force while its dimensional change (e.g., L) is measured using a (LVDT) probe. The total signal \Delta L_{\text{total}} is then separated into reversing (\Delta L_{\text{rev}}, associated with ) and non-reversing (\Delta L_{\text{non-rev}}, linked to irreversible processes like cure or ) components via of the oscillatory data. The mathematical basis relies on to isolate the in-phase and out-of-phase responses. The reversing component follows the modulation, yielding the reversible coefficient of (CTE) as \alpha_{\text{rev}} = \frac{\Delta L_{\text{rev}}}{L_0 \Delta T_{\text{mod}}}, where L_0 is the and \Delta T_{\text{mod}} = 2A represents the peak-to-peak . The non-reversing signal is obtained by : \Delta L_{\text{non-rev}} = \Delta L_{\text{total}} - \Delta L_{\text{rev}}. Phase-sensitive detection corrects for lags due to , ensuring accurate separation even for overlapping transitions. This method offers significant benefits, including improved resolution of overlapping thermal events, such as distinguishing (T_g) from curing in thermosets, where conventional TMA might conflate expansion and shrinkage. For instance, in resins, MT-TMA resolves T_g at approximately 154 °C more precisely than standard methods, which show softening around 149 °C. Modulation periods of 100–300 s allow at least five cycles across a transition, enhancing signal-to-noise ratios without excessive experiment time. Limitations include the need for stable temperature modulation, which can be disrupted by samples with high or poor , leading to phase errors that require instrument-specific . Specialized software is essential for deconvolution and phase correction, and underlying ramp rates must remain low (≤2 °C/min) to avoid distorting the separation. Shorter periods below 100 s often yield inaccurate results due to thermal lag.

Zero-Stress TMA

Zero-stress thermomechanical analysis (TMA), also known as thermodilatometric analysis (TDA), measures the unconstrained dimensional changes of a material as a function of temperature under negligible mechanical load, providing the intrinsic linear coefficient of thermal expansion, α(T). The procedure involves placing the sample in a suitable holder, such as fused silica for high-temperature measurements, with a pushrod in light contact to transmit length variations to a (LVDT) sensor. A minimal , typically less than 0.01 N, is applied to ensure the probe follows the sample surface without imposing stress, enabling a pure dilatometric scan over heating or cooling rates from 0.001 K/min to 50 K/min. This setup isolates effects, avoiding artifacts from mechanical loading. A key variant is zero-force thermomechanometry, particularly applied to polymers, where the absence of load allows detection of subtle free-volume changes at the glass transition temperature (). In this mode, the material's expansion reflects molecular relaxations without external constraints, highlighting the transition from a rigid glassy state to a compliant rubbery state. For amorphous polymers, the expansion curve often exhibits a sigmoidal shape, with a low α_glassy (e.g., ~50 × 10^{-6} K^{-1} below ) shifting to a higher α_rubbery (e.g., ~150 × 10^{-6} K^{-1} above ), corresponding to increased chain mobility and free volume. The volume expansion coefficient, β, is derived by integration as β = 3α for isotropic materials, aiding in volumetric property assessments. This technique serves as a for comparing stress-induced behaviors in loaded TMA variants and extends to cryogenic applications for metals, where precise α(T) measurements down to 4 reveal low-temperature anomalies like negative in certain alloys. For instance, dilatometric scans on bulk metallic at cryogenic temperatures quantify minimal coefficients, essential for and superconducting components.

Applications and Analysis

Material Characterization in Polymers

Thermomechanical analysis (TMA) plays a crucial role in characterizing the structure of polymers by measuring dimensional changes under controlled temperature and load conditions, revealing transitions and phase behaviors that influence mechanical properties. In semi-crystalline polymers, TMA detects shrinkage during cooling as amorphous regions crystallize, forming ordered structures that reduce overall thermal expansion. This shrinkage is quantified through the coefficient of thermal expansion (CTE), which decreases with increasing crystallinity due to the lower expansion of crystalline domains compared to amorphous ones. The degree of crystallinity in semi-crystalline polymers can be estimated from TMA data by comparing the measured CTE to known values for fully amorphous and fully crystalline phases. This approach leverages the distinct thermal expansion behaviors: amorphous regions expand more freely, while crystalline regions constrain expansion, allowing TMA to assess crystallinity levels typically ranging from 10% to 80% in polymers like polyethylene. For instance, in polyethylene terephthalate (PET) films, TMA has been used to correlate annealing-induced changes in expansion curves with increased crystallinity, showing a stepwise penetration behavior linked to surface and bulk crystallization. In cross-linked polymers, TMA assesses dimensional stability after curing, where the formation of a three-dimensional restricts . The point, marking the onset of significant cross-linking, is detected as an arrest in expansion during heating, transitioning the material from a to a solid-like state. This is particularly useful for thermosets, where post-cure TMA curves show reduced and minimal shrinkage, indicating . Specific examples illustrate TMA's utility in polymer characterization. In poly(methyl methacrylate) (PMMA), an amorphous polymer, TMA reveals the glass transition temperature (Tg) at approximately 105°C through a sharp change in expansion rate under tensile load, reflecting the shift from glassy to rubbery behavior. For semi-crystalline (), TMA identifies the melting temperature (Tm) around 130°C, with changes in expansion behavior upon melting, alongside in oriented fibers where axial and transverse CTEs differ significantly due to chain alignment. These measurements highlight how TMA captures molecular-level structural effects on macroscopic dimensions. Beyond pure polymers, TMA evaluates composites, such as those in printed circuit boards (PCBs), where CTE mismatch between matrices and fillers like glass fibers causes warpage under thermal cycling; TMA quantifies these mismatches to predict reliability, with typical CTEs of 20-100 × 10^{-6}/K contrasting lower filler values. In the 2020s, advances in biodegradable polymers, such as () composites, have utilized TMA to optimize thermomechanical stability for sustainable applications, revealing enhanced crystallinity and reduced expansion in reinforced for and biomedical uses.

Interpretation of TMA Data

Interpreting data from thermomechanical analysis (TMA) involves examining the dimensional change (ε) as a function of (T) or time to identify transitions and quantify properties. Typical TMA curves exhibit characteristic features such as inflections at the temperature (Tg), where the slope of the dilatometric curve steepens due to an increase in the coefficient of , and contractions at the melting temperature (Tm) for semicrystalline polymers, reflecting a squeeze-out of or under load. The tangent method is commonly applied to determine transition temperatures by drawing tangents to the linear portions of the curve before and after the transition region; the intersection point defines the onset temperature, such as , and this approach is independent of applied force in mode. of TMA data often employs to compute the dε/dT, which directly yields the temperature-dependent coefficient of linear α(T) = (1/L₀) · (dε/dT), where L₀ is the initial sample length. Baseline subtraction is a key preprocessing step to eliminate artifacts from instrument drift or sample mounting, ensuring accurate identification of true material responses. Error sources in TMA data interpretation include thermal gradients across the sample, which can distort measured by introducing non-uniform heating; these are mitigated through careful sample sizing (e.g., ~5 mm height) and validation using reference materials like to quantify temperature differences. Reproducibility for coefficient of (CTE) measurements typically achieves precision on the order of 5%, influenced by factors such as heating rate and atmosphere control. Modern TMA software facilitates advanced interpretation through automated peak fitting, often using Gaussian or sigmoidal models to deconvolute overlapping transitions in the dimensional change curve, and supports reporting in accordance with ASTM E831, which specifies calculation of mean CTE as α = ΔL / (L₀ · ΔT) over defined temperature intervals with details on and .

Distinctions from DMA and DSC

Thermomechanical analysis (TMA) differs from (DMA) primarily in the type of mechanical loading applied and the properties measured. TMA employs a quasi-static load to assess dimensional changes, such as linear expansion or contraction, making it particularly suited for determining the coefficient of thermal expansion (CTE) in materials like polymers. In contrast, DMA uses oscillatory or to probe viscoelastic behavior, yielding data on storage modulus, loss modulus, and loss tangent (tan δ), which provide insights into molecular relaxations and dynamic mechanical spectra. This distinction allows TMA to offer simpler, more direct measurements of under controlled , while DMA excels in capturing frequency-dependent responses for comprehensive viscoelastic characterization. Compared to (), TMA provides mechanical and dimensional information rather than purely thermal data. quantifies heat flow differences to measure changes associated with transitions, such as or , without directly assessing physical dimensions. TMA, however, tracks softening, expansion, or penetration under load, revealing how mechanical stress influences material behavior during thermal events like the . These complementary approaches are often used together; for instance, identifies thermodynamic transitions, while TMA evaluates their impact on dimensional stability, enabling a fuller mapping of material responses in applications like polymer processing. All three techniques can detect the glass transition temperature (Tg) in polymers, but they do so with varying sensitivities and influences. TMA and DMA are particularly responsive to Tg through changes in expansion or modulus, respectively, and TMA's application of stress can induce shifts in Tg values compared to the stress-free conditions in DSC. Overlaps exist in their ability to identify transitions, yet TMA offers good resolution for Tg, though generally less precise than DSC for heat flow events. DMA provides the highest sensitivity to subtle relaxations, though Tg detection temperatures can vary by technique and conditions. Selection among TMA, DMA, and DSC depends on the targeted properties: TMA is preferred for engineering-focused assessments of dimensional changes and CTE under load, essential for predicting service performance in structural components. DMA is chosen for detailed viscoelastic analysis in dynamic environments, such as in composites. DSC suits fundamental thermodynamic studies, like curing or , where mechanical effects are secondary. Integrating these methods ensures robust material characterization, with TMA bridging mechanical and thermal domains effectively.

Complementary Methods and Terminology

Thermomechanometry (TMM) is a broader term proposed for thermoanalytical techniques measuring changes in mechanical properties under , with thermomechanical analysis (TMA) as a key subdiscipline focusing on dimensional changes under controlled conditions. In specific applications, zero-force TMM is equivalent to dilatometry, where no external load is applied to the sample, allowing direct assessment of unconstrained or contraction. in TMA quantifies a material's deformability under applied , representing the inverse of , whereas indicates or resistance to deformation, with both derived from -strain curves during temperature-programmed tests. Complementary thermal analysis methods enhance TMA by providing correlated data on material behavior. Thermogravimetric analysis (TGA) complements TMA by measuring mass loss alongside dimensional changes, enabling correlation of thermal stability, decomposition, and expansion events in polymers and composites. Dilatometry extends TMA for evaluating large-volume changes in solids, particularly in ceramics and metals, where it focuses on precise linear thermal expansion coefficients over extended temperature ranges. Rheometry supports TMA in analyzing viscoelastic liquids and melts, offering insights into flow properties and shear-dependent responses that TMA alone cannot capture in non-solid states. Integrations of TMA with other techniques form multi-method workflows for comprehensive material studies. For instance, combining TMA with Fourier-transform infrared (FTIR) tracks cure in thermosets by linking dimensional shrinkage to progress during . Emerging in-situ TMA approaches incorporate optical to observe microstructural evolution, such as phase transitions or cracking, in real-time under thermal loading. A standards glossary for TMA draws from authoritative bodies. The International Confederation for Thermal Analysis and Calorimetry (ICTAC), in collaboration with IUPAC, defines TMA as a measuring sample deformation under non-oscillating as a function of or time, encompassing terms like linear expansion coefficient and . Post-2015 updates to ISO 11359-1 (revised in 2023) include provisions for optional cooling devices, single sensor-DTA temperature calibration, and expanded calibration substances to improve accuracy in plastics analysis.

References

  1. [1]
    [PDF] Thermomechanical Analysis – TMA 512 Hyperion® Series
    Thermomechanical analysis (TMA) is a technique for determining the dimensional changes in solids, liquids or pasty materials as a function of.
  2. [2]
    [PDF] THERMOMECHANICAL ANALYSIS - TA Instruments
    Applications. TMA APPLICATIONS. Stress Relaxation Analysis. This figure shows a stress relaxation test in tension on the same polyolefin film used for the ...Missing: principles | Show results with:principles
  3. [3]
    [PDF] Dynamic Mechanical Analysis (DMA) A Beginner's Guide
    A Thermomechanical Analysis, or TMA, applies a constant static force to a material. and watches the material change as temperature or time varies. It reports ...Missing: definition | Show results with:definition<|control11|><|separator|>
  4. [4]
    Thermomechanical Analysis
    ### Summary of Thermomechanical Analysis (TMA)
  5. [5]
    E831 Standard Test Method for Linear Thermal Expansion of Solid ...
    May 7, 2024 · This test method determines the technical coefficient of linear thermal expansion of solid materials using thermomechanical analysis techniques.
  6. [6]
    Thermomechanical Analyzer (TMA) - NETZSCH Analyzing & Testing
    Thermomechanical analysis (TMA) is a technique for determining the dimensional changes in solids, liquids or pasty materials as a function of temperature and/ ...
  7. [7]
    Coefficient of Linear Thermal Expansion (CLTE) - ASTM E831
    CLTE (α) is calculated using the formula: α = ΔL / (Lo * ΔT) where ΔL is the change in length of the specimen, Lo is the original length of the specimen,
  8. [8]
    Thermomechanical Analysis | TMA - EAG Laboratories
    Thermomechanical Analysis (TMA) is used to characterize physical properties of materials when force is applied at specified temperatures and time periods.
  9. [9]
    Dilatometer (DIL) - Thermal expansion measurement from - Linseis
    Dilatometry is therefore ideal for investigations into thermal expansion, shrinkage and sintering behavior, while TMA concentrates on mechanical deformation ...
  10. [10]
    Thermomechanical Analysis (TMA) - NETZSCH Analyzing & Testing
    TMA measures these dimensional changes while allowing the sample to be subjected to an additional mechanical load (DIN 51005, ASTM E 831, ASTM D 696, and ASTM D ...
  11. [11]
    Charles Edouard Guillaume – Facts - NobelPrize.org
    However, different materials expand differently when temperatures change, which limits the ability to make very precise measurements. In 1896 Charles-Edouard ...
  12. [12]
    [PDF] Basics of Thermomechanical Analysis with TMA 4000 | S4Science
    The need for a commercial TMA grew from hardness or penetration tests and was used on polymers in 19481. Subsequently, it has developed into a powerful tool in ...Missing: DuPont Guillaume
  13. [13]
    Thermomechanical Analysis | Materials Characterization | Handbooks
    An early distinction between TMA and dilatometry was that TMA was the measurement of deformation of a material under a nonoscillatory load, while dilatometry ...<|control11|><|separator|>
  14. [14]
    Thermal Analysis - PerkinElmer
    For your Thermal Analysis needs, turn to PerkinElmer's comprehensive portfolio of instruments, consumables, software, and service.Missing: historical DuPont Guillaume<|control11|><|separator|>
  15. [15]
    Review and prospect of thermal analysis technology applied to ...
    Around 1960s, thermal analysis technology developed rapidly. After 1980s, a variety of new thermal analysis technologies, such as differential scanning ...
  16. [16]
    Nanoscale Thermal Analysis of Polymers - AZoNano
    Jun 22, 2009 · The Thermal Analysis (VITA) module enables nanoscale thermal analysis (nTA), a novel technique that allows the determination of the local transition ...Missing: 2000s | Show results with:2000s
  17. [17]
    [PDF] LA-UR-24-22990 - OSTI.GOV
    Apr 2, 2024 · ABSTRACT: A literature review of thermomechanical analysis (TMA) is presented. A basic introduction to TMA components, theory, and ...
  18. [18]
    Thermomechanical Analysis | TMA/SDTA Instruments - Mettler Toledo
    Thermomechanical analysis (TMA) is used to measure the dimensional changes of a material as a function of temperature. This includes expansion coefficients ...
  19. [19]
    Calibration of TMA According to ASTM Standard Method E-831
    For accurate measurement of the CTE), it is necessary to calibrate the expansion response of the thermomechanical analyzer (TMA) using reference materials.
  20. [20]
    E831 Standard Test Method for Linear Thermal Expansion of Solid ...
    Apr 9, 2019 · This test method determines the technical coefficient of linear thermal expansion of solid materials using thermomechanical analysis techniques.
  21. [21]
  22. [22]
    [PDF] The Correlation of TMA with ASTM Modulus Data - TA Instruments
    The VICAT softening temperature is defined by ASTM (3) as the temperature at which a circular probe of 1.0 mm2 cross-section, under load of 1000 gm, penetrates ...
  23. [23]
    Determination of Softening by Penetration Measurements by TMA
    The TMA curves show the relative penetration depth of the ball-point probe with reference to the initial sample thickness as a function of temperature.
  24. [24]
    Principle of Thermomechanical Analysis (TMA) - Hitachi hightech
    A technique in which a deformation of the sample under non-oscillating stress is monitored against time or temperatureMissing: thermoelasticity | Show results with:thermoelasticity
  25. [25]
    Thermomechanical Analysis (TMA) of Plastic Materials - AIMPLAS
    In this article, we explore how TMA can help measure key properties such as softening temperature, glass transition temperature, melting point and the ...Missing: Tg | Show results with:Tg
  26. [26]
    Thickness-direction coefficient of thermal expansion measurement ...
    The a values were determined from a least-squares fit and had standard ... coefficient of thermal expansion in the thickness direction for thin polymer films.
  27. [27]
    Thermomechanical study of low-density polyethylene, polyamide 6 ...
    The TMA can detect several relaxation transitions in polymers, which differ in interaction energy between segments of macromolecules, and as a result, in ...
  28. [28]
    [PDF] THERMAL ANALYSIS - TA Instruments
    Displacement Resolution. <0.5 nm. <0.5 nm. Dynamic Baseline Drift. <1 µm (-100 to 500°C). <1 µm (-100 to 500°C). Force Range. 0.001 to 2 N. 0.001 to 2 N. Force ...
  29. [29]
    US5710426A - Dynamic and thermal mechanical analyzer having ...
    TMA can be used to determine the properties of the same wide ... 9 is a schematic diagram of a dual cantilever flexure mode sample clamping fixture.
  30. [30]
    [PDF] Simple Bending Theory OR Theory of Flexure for Initially Straight ...
    Simple bending theory assumes a straight beam with constant cross-section, pure bending (zero shear), and plane cross-sections remain plane after bending.
  31. [31]
    Thermo-mechanical analysis of composite beams - ScienceDirect.com
    Feb 15, 2017 · The proposed method has been applied to solve a significant set of thermo-mechanical composite beam problems and, to show its efficiency, the 3D-resultsMissing: flexure | Show results with:flexure
  32. [32]
    [PDF] 94 Thermomechanical, dynamic mechanical & dielectric methods
    Thermomechanical Analysis and Thermodilatometry​​ Thermomechanical Analysis (TMA) can be defined as the measurement of a specimen's dimensions (length or volume) ...
  33. [33]
    Thermal Mechnical Analyser (Mettler Toledo TMA/SDTA1) | UMF
    The load can be compression, tension, flexure or torsion. Mettler Toledo TMA/SDTA1 measures the sample temperature very close to the sample in all operating ...
  34. [34]
  35. [35]
    (PDF) Shear Moduli of Structural Composites from Torsion Tests
    Sep 4, 2025 · The shear moduli are obtained from the experimental torsional stiffnesses (T/) and data reduction techniques based on torsion solutions by ...Missing: TMA | Show results with:TMA
  36. [36]
    None
    ### Summary of Torsion Mode in Thermomechanical Analysis (TMA)
  37. [37]
    9: Thermomechanical, Dynamic Mechanical and Dielectric Methods
    Feb 25, 2016 · Common mechanical deformation modes: compression, tension, shear, torsion, bending (single cantilever, dual cantilever, three point bending).
  38. [38]
  39. [39]
    [PDF] Discovery TMA 450 - TA Instruments
    This example demonstrates the use of the expansion probe to accurately measure CTE changes in an aluminum sample over a 200°C temperature range. TRIOS software ...
  40. [40]
    [PDF] handbook of thermal analysis and calorimetry - Pyrotechnics
    Apr 2, 2012 · ... ADVANTAGES OF SCTA. 430. 6. KINETIC ASPECTS. 434. 7. PROSPECTS FOR THE ... Dynamic force thermomechanical analysis (df-TMA): Techniques in ...<|control11|><|separator|>
  41. [41]
    [PDF] Modulated Thermomechanical Analysis – Measuring Expansion and ...
    In modulated thermal analysis, a sinusoidally varying temperature program is added to an underlying linearly changing or static temperature program.Missing: benefits limitations
  42. [42]
    [PDF] Modulated-Temperature Thermomechanical Measurements
    Thermomechanical analysis (TMA) involves measurement of the response of a material to a constant load or deformation as a function of temperature [5].
  43. [43]
    Temperature-modulated thermomechanical analysis as a potential ...
    Jun 21, 2016 · One of the most important advantages of this technique is that all previously described information can be received from only one heating cycle.Missing: procedure basis benefits limitations
  44. [44]
    [PDF] TMA 402 F1/F3 Hyperion® - NETZSCH Analyzing & Testing
    Thermomechanical analysis (TMA) is a technique for determining the ... The RCS measurement in expansion mode (Al2O3 sample carrier), SiC furnace.Missing: setup | Show results with:setup
  45. [45]
    [PDF] exploring the sensitivity of thermal analysis techniques to the glass ...
    TMA is generally used to measure the glass transition based on changes in coefficient of thermal expansion which result as the free volume of the material ...
  46. [46]
    Measurement of the thermal expansion of bulk metallic glass in ...
    Apr 15, 2025 · In this study, we developed a new thermal expansion measurement system that can measure thermal expansion more conveniently than conventional measurement ...Missing: zero- TMA
  47. [47]
    [PDF] Thermal expansion of technical solids at low temperatures
    in the temperature range, 0 to 300 °K. Introduction. This publication was intended to fill a need among designers of cryogenic equipment ...Missing: TMA | Show results with:TMA
  48. [48]
    When to Use Thermomechanical Analysis to Characterize Your ...
    Apr 21, 2022 · TMA is a vertical dilatometry technique used to measure thermal expansion behavior and related properties (glass transition, crystal-crystal phase transition, ...
  49. [49]
    Study of crystallinity and thermomechanical analysis of annealed ...
    Aug 6, 2025 · ... degree of crystallinity of a series of heat-set poly ... This method is based on the thermomechanical analysis of a solid polymer.
  50. [50]
    Degradation of aromatic polymers—II. The crosslinking during ...
    ... gel point by gel permeation chromatography and by a new method using thermomechanical analysis. It was suggested by i.r. study that crosslinking occurs by ...
  51. [51]
    Educational series: characterizing crosslinked polymer networks
    Dec 19, 2023 · Thermomechanical analysis (TMA) measures the deformation or changes ... Static Scaling above the Gel Point, Macromolecules, 1992, 25(26) ...
  52. [52]
    Tg determination with TMA: How thermoplastics react under ...
    The glass transition temperature (Tg) marks the transition of a thermoplastic from a brittle, glass-like state to a rubber-like behavior.Why Tg Measurement Under... · Pmma Films: Tg Deviation... · The Role Of Tma In Material...
  53. [53]
    Thermomechanical studies of surface mounted microelectronics by ...
    Apr 1, 2019 · The coefficient of thermal expansion (CTE) mismatch between package and PCB ... Thermomechanical stability of the PCB as a composite ...
  54. [54]
    Thermomechanical and Viscoelastic Behavior of Biodegradable and ...
    Aug 6, 2025 · ... thermomechanical analysis, thermal stability, [Formula: see text] ... biodegradable polymers are inadequate. Recent research has focused ...
  55. [55]
    [PDF] Interpreting TMA curves - Mettler Toledo
    The dilatometric curve (measured with negligible compressive stress) usually exhibits an upward tendency due to the thermal expansion of the sample. The TMA ...
  56. [56]
    None
    ### Summary of Historical Information on Thermal Analysis Techniques (TMA, Dilatometry)
  57. [57]
    Dynamic Mechanical Analysis | DMA/SDTA - Mettler Toledo
    In addition to dynamic measurements, the METTLER TOLEDO DMA 1 also offers TMA (thermomechanical analysis) mode, allowing for precise measurements using static ...
  58. [58]
    Introduction to Dynamic Mechanical Analysis and its Application to ...
    Dynamic Mechanical Analysis (DMA) is an extremely powerful technique to characterize the thermal and mechanical properties of solid samples.Missing: distinctions | Show results with:distinctions
  59. [59]
  60. [60]
    Principle of Thermal Analysis (DSC, STA, TMA & DMA)
    Definitions of Thermomechanical Analysis (TMA) · Definitions of Dynamic Mechanical Analysis (DMA). New Analysis Techniques. Controlled Rate Thermal Analysis ...Missing: distinctions | Show results with:distinctions
  61. [61]
    [PDF] Materials Characterization by Thermal Analysis (DSC & TGA ...
    Thermo-mechanical Analysis measures changes in the dimensions of a sample as a function of time, temperature and force in a controlled atmosphere. • TMA can ...<|separator|>
  62. [62]
    TGA, TMA, and DMA Analysis of Thermoplastics - AZoM
    Jun 27, 2018 · This article focuses on the application of thermogravimetric analysis (TGA), thermomechanical analysis (TMA), and dynamic mechanical analysis (DMA) techniques.
  63. [63]
    Glass Transition Measurement - Mettler Toledo
    The figure shows three different curves of polystyrene (PS) obtained from Differential Scanning Calorimetry (DSC), Thermomechanical Analysis (TMA) and Dynamic ...
  64. [64]
    Mechanical Analysis (DMA & TMA) - PerkinElmer
    Dynamic Mechanical Analysis (DMA) and Thermomechanical Analysis (TMA) are widely used to characterize materials' bulk properties such as modulus.Missing: first | Show results with:first
  65. [65]
    A review on thermomechanical properties of polymers and fibers ...
    Research study elaborated that TMA can effectively be used either alone or in conjunction with other commercially available TA techniques such as DSC, TGA, DMA ...
  66. [66]
    Thermal Mechanical Analysis - an overview | ScienceDirect Topics
    The torsion mode of the rheometer is used to capture the evolution of the elastic modulus with the cure. The shear moduli can be related to the degree-of-cure ...
  67. [67]
    A high-stability non-contact dilatometer for low-amplitude ...
    Jul 26, 2016 · For thermomechanical analysis (TMA), which in the case of zero force is equivalent to dilatometry, a modulated method was described by Price.
  68. [68]
    Thermomechanical analysis - Wikipedia
    Thermomechanical analysis (TMA) is a technique used in thermal analysis, a branch of materials science which studies the properties of materials as they change ...Related techniques and... · Mechanical test · Zero-stress... · Static-force TM
  69. [69]
    [PDF] Thermal Characterization of Polymers | Nexus Analytics
    Top-level polymer research and characterization can be achieved by coupling the thermoanalytical methods of. TGA, DSC, STA, TMA and DIL to a mass spectrometer ( ...
  70. [70]
    DSC and Rotational Rheometry: Two Complementary Techniques
    Sep 30, 2022 · Rheometry is a complementary technique that provides information about the viscosity and the viscoelastic properties of materials.
  71. [71]
    Kinetics study of curing by FT-IR and Dynamic Thermomechanical ...
    Aug 6, 2025 · This work has focused on the study of a commercially-available epoxy resin manufactured especially for glass conservation and treatment, ...Missing: Multi- workflows TMA
  72. [72]
    Transmission electron microscopy with in-situ ion irradiation
    This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities.
  73. [73]
    (PDF) ICTAC nomenclature of thermal analysis (IUPAC ...
    Included in the document are the definitions of 13 techniques, 54 terms within the glossary, as well as symbols and units. ResearchGate Logo. Discover the ...
  74. [74]
    [PDF] ISO 11359-1 - Thermomechanical analysis (TMA) - iTeh Standards
    Calibrate the temperature display (5.1) using two or more calibration materials covering the temperature range to be used for the test specimen. Calibration ...