Fact-checked by Grok 2 weeks ago
References
-
[1]
A Review of Dissolved Gas Analysis in Power TransformersDissolved gas analysis (DGA) provides insights into thermal and electrical stresses in transformers, detects incipient faults, and helps prevent further damage.
-
[2]
[PDF] IEEE DISSOLVED GAS ANALYSIS GUIDELINES | Facility ResultsA one to four condition DGA guide is used to classify risks to transformers with no previous problems has been developed by the IEEE [11]. The guide uses ...
-
[3]
DGA Test Standards: IEC vs IEEE – What You Need to Know - MeggerOct 7, 2025 · Emphasis on Trending: The IEEE standard places greater emphasis on gas generation rates and trending analysis rather than absolute concentration ...
-
[4]
IEEE C57.104-2019Nov 1, 2019 · Detailed procedures for analyzing gas from gas spaces or gas-collecting devices as well as gas dissolved in oil are described.
-
[5]
[PDF] Guide for Interpreting Dissolved Gases in Liquid-filled TransformersJun 1, 2023 · This Guide is a tutorial and reference document whose purpose is to teach the reader how to do DGA interpretation, making use of several ...
-
[6]
None### Summary of Dissolved Gas Analysis (DGA) from GE Vernova Document
-
[7]
NoneSummary of each segment:
-
[8]
[PDF] A CENTURY OF DISSOLVED GAS ANALYSIS - PART IItransformers history facts relevant to gassing issues. 1836 - 1885 - transformer was invented in Europe and in the US. 1900 - Gas chromatography invented by ...
-
[9]
Conventional Dissolved Gases Analysis in Power Transformers - MDPIOct 24, 2023 · From the 1960s onwards, gas chromatography (GC) saw its first applications in identifying dissolved gases in transformers from electrical faults ...
-
[10]
Using Dissolved Gas Analysis to Detect Active Faults in Oil-Insulated ...However, this technique was not applied specifically to transformer mineral oil until the late 1960s/early 1970s and is now commonly called dissolved gas-in-oil ...
-
[11]
Dissolved gas analysis of transformers using fuzzy logic approachApr 14, 2009 · Rogers method for dissolved gas-in-oil analysis (DGA). The Rogers ratio method was introduced for the first time in 1973 and was improved in ...
-
[12]
Machine learning based multi-method interpretation to enhance ...Feb 29, 2024 · The Duval triangle method was introduced for the first time in 1974, employing a combination of three hydrocarbon gases: CH4, C2H4, and C2H2, ...
-
[13]
DGA | PDF | Carbon Dioxide | Gases - ScribdThe Duval Triangle method uses concentrations of methane, ethylene, and acetylene to plot results on a triangle diagram and identify fault types. It has been ...
-
[14]
IEEE/PES Transformers CommitteeMar 26, 2020 · IEEE C57.104 "Guide for the Interpretation of Gases Generated in Mineral Oil-Immersed Transformers," originally introduced in 1978, is ...
-
[15]
[PDF] Chemical Sensing Strategies for Real-time Monitoring of ... - OSTI.GOVOn-line dissolved gas analysis monitors were invented in the late 1990s. [9], which measured the concentrations of hydrogen and other combustible gas in ...
-
[16]
Integrating offline and online Dissolved Gas Analysis (DGA ...Nov 3, 2025 · The integration of offline and online Dissolved Gas Analysis (DGA) methodologies can be a framework for predictive transformer maintenance.
-
[17]
Experiences in Service with New Insulating Liquids - eCIGREExperiences in Service with New Insulating Liquids · This publication is free only for CIGRE members · Price for non member: 180 €.
-
[18]
Learn about Polychlorinated Biphenyls | US EPAThey have a range of toxicity and vary in consistency from thin, light-colored liquids to yellow or black waxy solids. Due to their non-flammability, chemical ...Missing: phased | Show results with:phased
-
[19]
Transformer Oil: Testing, Types & Properties - Electrical4UMay 3, 2024 · Transformer oil (also known as insulating oil) is a special type of oil which has excellent electrical insulating properties and is stable at high temperatures.
- [20]
-
[21]
Influence of cellulose paper on gassing tendency of transformer oil ...The intent of this work is to evaluate the influence of cellulose insulation paper on gassing tendency of transformer oil under electrical discharge ...
- [22]
-
[23]
Online dissolved gas analysis used for transformers – possibilities ...Feb 16, 2022 · The solubility of the investigated hydrocarbons (C2H2, C2H4, C2H6 and CH4) increases with rising temperature, whereas the solubility of ...Missing: law | Show results with:law
-
[24]
(PDF) Solubility study of different gases in mineral and ester-based transformer oils### Solubility of H₂ and CH₄ in Mineral Oil and Esters
-
[25]
D923 Standard Practices for Sampling Electrical Insulating LiquidsDec 27, 2023 · These practices cover sampling of new electrical insulating liquids including oils, askarels, silicones, synthetic liquids, and natural ester insulating ...
-
[26]
[PDF] sample container selection for insulating liquids - Doble EngineeringASTM D923, Standard Practice for Sampling. Electrical Insulating Liquids provides a list of sample containers and the advantages and disadvantages of each and ...<|separator|>
-
[27]
The Right Way to Sample a Transformer - Southwest Electric CoMar 1, 2024 · How Much Oil Should I Pull? ASTM D- 923 states that whenever you sample a transformer you should flush 2 liters of oil. This can be a lot of ...
-
[28]
[PDF] LIQUID SAMPLING INSTRUCTIONS - SDMyersFlush the valve as follows: 50 oz. for a ... These instructions are intended to provide some basic guidance on drawing your own transformer liquid samples.
-
[29]
[PDF] Method 9079: Screening Test Method for Polychlorinated Biphenyls ...6.0 SAMPLE COLLECTION, PRESERVATION, AND HANDLING. 6.1 See the introductory material to this chapter, Organic Analytes, Section 4.1. 6.2 Oil samples may be ...
-
[30]
[PDF] Headspace-GC Analysis of Dissolved Gases in Transformer Oil ...ASTM D-3612 offers three methods for the DGA analysis1: • Method A: Vacuum extraction. Dissolved gases from the transformer oil are extracted by vacuum using a ...Missing: dynamics | Show results with:dynamics
-
[31]
[PDF] Transformer Oil Gas Analyser According to ASTM D 3612c Small ...ASTM D 3612 describes three procedures for the extraction and determination of gases in transformer oil. This application note is based on part C, using head ...
-
[32]
[PDF] The world of DGA – and its uncertainties - VaisalaDGA and its utilization in transformer diagnostics is not exact science, but rather an evaluation method based on statistics and empirical data.
-
[33]
Dissolved gas analysis - Academic Dictionaries and EncyclopediasThe collection and analysis of gases in an oil-insulated transformer was discussed as early as 1928. Many years of empirical and theoretical study have gone ...
-
[34]
Transformer Oil Gas Analysis via Headspace Sampling (ASTM D3612)Headspace sampling involves transferring dissolved gases from oil to a headspace in a closed vessel, then using a GC to analyze the gases.
-
[35]
Standard Test Method for Analysis of Gases Dissolved in Electrical ...Dec 13, 2017 · ASTM D3612 is a test method for analyzing gases in electrical insulating oil using gas chromatography, covering extraction and measurement of ...
- [36]
-
[37]
[PDF] Automated GC sample prep of dissolved gas-in-oil - PAL SystemIn combination with a PAL RTC and a GC-MS system, Oleo allows the automated analysis of 30 samples of oil by headspace, to quantify permanent gases, methane, ...<|control11|><|separator|>
-
[38]
Dissolved Gas Analysis Limits | ELSCO TransformersMay 16, 2024 · DGA gives you valuable insight into a transformer's condition through concentration and trend analysis of dissolved gases in transformer oil.
-
[39]
[PDF] Dissolved Gas Analysis is an Art of Testing and ... - CPRI JournalIn DGA testing and Analysis first aim should be to get the correct amount of gas content in oil using the latest gas extraction methodology and sensitive gas.
-
[40]
Static headspace gas chromatographic determination of fault gases ...The method of choice for the determination of fault gases in transformer oils is the so-called dissolved gas analysis (DGA). Dissolved gas analysis is a common ...
-
[41]
Dissolved Gas Analysis Procedure Based on IEEE C57.104-2019May 31, 2025 · This article outlines the suggested Dissolved Gas Analysis interpretation procedure from the IEEE Std C57.104-2019, offering a structured ...
-
[42]
Traditional fault diagnosis methods for mineral oil‐immersed power ...Apr 22, 2024 · The authors present a detailed and comprehensive literature review of the traditional DGA-based methods for mineral oil-immersed power transformer faults ...
-
[43]
IEEE Guide for the Interpretation of Gases Generated in Mineral Oil ...Nov 1, 2019 · The purpose of this document is to provide a guide for evaluating dissolved gases analysis results from mineral oil-immersed transformers.
- [44]
-
[45]
Diagnostic Simplexes for Dissolved-Gas Analysis - MDPIA Duval triangle is a diagram used for fault type identification in dissolved-gas analysis of oil-filled high-voltage transformers and other electrical ...
-
[46]
The Duval Triangle for Load Tap Changers, Non-Mineral Oils and ...Aug 7, 2025 · The present paper reviews these DGA results in a more user-friendly graphical form. It also reviews the DGA results of laboratory models ...
-
[47]
A Reviewed Turn at of Methods for Determining the Type of Fault in ...May 12, 2024 · The Doernenburg Ratio Method. This method was proposed in 1974 and used for the recognition of incipient faults using the technique of key gas ...<|separator|>
-
[48]
[PDF] IEEE Guide for the Interpretation of Gases Generated in Mineral Oil ...Nov 1, 2019 · This guide describes procedures for interpreting Dissolved Gas Analysis (DGA) results in mineral oil-immersed transformers, including gas ...
- [49]
-
[50]
Fuzzy Logic Approach to Dissolved Gas Analysis for Power ... - MDPIThis paper proposed a fuzzy logic system for power transformer fault assessment based on the three DGA methods; key gas, IEC ratio, and Duval triangle method ...
-
[51]
Multiclass Fault Diagnosis in Power Transformers Using Dissolved ...Studies have indicated that approximately 70–80% of transformer faults are incipient, highlighting the importance of early detection to prevent fault escalation ...
-
[52]
Dissolved Gas Analysis (DGA) by EPRI Disposable Oil Sampling ...Fluid-filled equipment -- which includes transformers, cables, bushings, terminations, and circuit breakers -- is an integral part of the electrical system.
-
[53]
Gassing in Wind Turbine Transformers - TJ|H2b Analytical ServicesFeb 2, 2023 · Local transformers, those directly linked to the turbine of a wind farm, generate abnormally high amounts of dissolved gases.
-
[54]
Dissolved Gas Analysis - integratedSCADAIntegrating DGA data into the SCADA system allows historical trending, alarming and real-time monitoring. In this case the rate of change of values over ...
-
[55]
Cut Costs with Transformer Monitoring - Dynamic RatingsJul 8, 2025 · Condition-based monitoring provides a cost-effective solution, empowering utilities to adopt a proactive approach to monitoring their assets.Missing: savings deferred
-
[56]
Experiences with transformer diagnosis by DGA: case studiesNov 7, 2019 · In this study, after reviewing the significant points in the DGA procedure, five real cases are reported which explain the transformer diagnosis by DGA.
-
[57]
IEC 60599:2022May 25, 2022 · IEC 60599:2022 describes how the concentrations of dissolved gases or free gases can be interpreted to diagnose the condition of oil-filled electrical ...
-
[58]
[PDF] INTERNATIONAL STANDARD NORME INTERNATIONALE IEC 60599This document describes how the concentrations of dissolved gases or free gases can be interpreted to diagnose the condition of oil-filled electrical equipment ...
-
[59]
IEC 60567:2023Dec 8, 2023 · Three basic methods are described, one using extraction by vacuum (Toepler and partial degassing), another by displacement of the dissolved ...