Fact-checked by Grok 2 weeks ago

Nanoparticle tracking analysis

Nanoparticle tracking analysis (NTA) is a biophysical that visualizes and characterizes nanoparticles in liquid suspensions by illuminating them with a laser beam and tracking their individual using high-resolution and . The method calculates the hydrodynamic diameter of particles from their diffusion coefficients via the Stokes-Einstein equation, providing number-weighted size distributions and concentration measurements typically for particles in the 10–1,000 nm range. First commercialized in by NanoSight (now part of Malvern Panalytical), NTA enables real-time monitoring and is particularly effective for polydisperse samples where it offers superior resolution compared to ensemble methods like (DLS). NTA operates by directing a finely focused beam through a sample chamber, where particles scatter that is captured at a 90-degree angle by a (CCD) or complementary metal-oxide-semiconductor () camera, generating a video sequence of particle trajectories. Specialized software analyzes the of each tracked particle to determine its size, with modes available for labeling and phenotyping specific subpopulations, such as extracellular vesicles (EVs) tagged with markers like or CD9. This single-particle resolution allows for accurate quantification at low concentrations (10^7–10^9 particles/mL) and minimal sample volumes (often <1 mL), making it non-destructive and suitable for dilute biological fluids like plasma or saliva. Key applications of NTA span pharmaceuticals, biotechnology, and materials science, including the characterization of drug delivery systems like liposomes and polymeric nanoparticles, monitoring protein aggregation in biotherapeutics, and analyzing EVs or viruses for diagnostic biomarkers in diseases such as cancer and Alzheimer's. It adheres to standards such as ISO 19430:2016 for particle tracking analysis and ASTM E2834-12 (reapproved 2018) for particle size analysis, ensuring reproducibility across instruments from manufacturers like Malvern Panalytical and HORIBA. While NTA excels in resolving multimodal distributions and detecting trace contaminants, limitations include sensitivity challenges for particles below 50 nm, the need for sample dilution to avoid multiple scattering, and potential overestimation in complex matrices due to non-target particles like protein aggregates. Ongoing advancements, such as improved data analysis algorithms like maximum-likelihood estimation with finite track length adjustment, continue to enhance its precision for polydisperse assemblies like macromolecular vesicles; recent developments as of 2025 include enhanced camera resolutions and multi-laser systems for improved detection of smaller particles.

Introduction

Overview and Definition

Nanoparticle tracking analysis (NTA) is a light-scattering-based technique that enables the direct visualization and individual tracking of nanoparticles in liquid suspension, typically in the size range of 10 to 1000 nm, by monitoring their Brownian motion to determine particle size, concentration, and distribution. This method utilizes a laser to illuminate particles, which are then captured via video microscopy for real-time analysis, providing particle-by-particle data that is particularly advantageous for polydisperse samples where ensemble averaging can obscure heterogeneity. The core purpose of NTA is to offer high-resolution characterization of nanoparticle populations using minimal sample volumes, typically requiring dilution for optimal concentration, and without mandatory labeling (though fluorescence modes are available), distinguishing it from ensemble techniques like dynamic light scattering (DLS), which measure average properties and may struggle with mixed-size distributions. Particle sizes are calculated as hydrodynamic radii using the Stokes-Einstein relation, which links the diffusion coefficient derived from tracked motion to the particle's effective size in suspension. NTA finds broad application in analyzing suspensions such as colloids, viruses, and biological nanoparticles like exosomes, with outputs including size histograms and concentration estimates that support fields like biomedicine. For instance, in biomedicine, it facilitates the quantification of extracellular vesicles for diagnostic and therapeutic research.

Historical Development

Nanoparticle tracking analysis (NTA) was invented by Bob Carr, a microbial biochemist with prior experience at the UK Centre for Applied Microbiology and Research, who recognized the need for a single-particle visualization technique to overcome the averaging limitations of ensemble methods like dynamic light scattering for characterizing polydisperse nanoparticle suspensions. In 2003, Carr co-founded with John Knowles to commercialize this laser-based light scattering microscopy approach, which tracks individual Brownian motions of nanoparticles in liquid to determine size and concentration. Early development led to foundational patents, including Carr's innovations in optical detection and particle trajectory analysis via light scattering, as detailed in NanoSight's core intellectual property filings such as GB2439551A for nanoparticle sizing systems. The first commercial NTA instrument, the microscope-based LM10, was launched in 2006, followed by the desktop LM20 and initial NTA software release in the same year, enabling real-time visualization and analysis of particles down to 10 nm. By 2008, the 100th system had been sold, with early adoption in exosome research demonstrated at the , marking NTA's entry into biological applications where precise enumeration of extracellular vesicles proved valuable. Throughout the 2010s, NTA gained widespread use in exosome studies, supported by over 500 peer-reviewed publications by 2012, and the launch of automated platforms like the NS500 in 2010, which enhanced throughput and standardization. A significant advancement occurred in 2013 with the NS300 system, which integrated fluorescence detection (fNTA) to enable phenotyping of labeled nanoparticles alongside size and concentration measurements, addressing needs in biomarker tracking for complex biological samples. Following Malvern Instruments' acquisition of NanoSight in 2013, further refinements continued, including software updates like version 3.4.4 in 2020 that improved handling of polydisperse samples through enhanced track analysis algorithms and machine learning for better resolution of overlapping particle distributions. In the 2020s, NTA evolved toward advanced variants like interferometric NTA (iNTA), introduced in 2022, which combines interferometry with tracking for label-free discrimination of particle types in polydisperse mixtures. In 2023, Malvern Panalytical launched the NanoSight Pro, featuring machine learning enhancements for faster and more precise analysis of polydisperse samples.

Principles of Operation

Brownian Motion and Particle Tracking

Brownian motion refers to the irregular, random displacement of nanoparticles suspended in a liquid medium, arising from incessant collisions with the surrounding solvent molecules. This thermal agitation causes particles to undergo erratic trajectories, with the extent of movement inversely related to particle size: smaller particles diffuse more rapidly than larger ones. In nanoparticle tracking analysis (NTA), Brownian motion serves as the physical basis for size determination, as the speed and path of each particle's displacement provide a direct measure of its diffusive behavior. The random motion is quantitatively characterized by the mean squared displacement (MSD), defined for two-dimensional trajectories as \langle \Delta r^2 \rangle = 4Dt, where \Delta r^2 is the squared displacement over a time lag t, and D is the diffusion coefficient; this relation stems from the for diffusive processes in dilute suspensions. Particle tracking in NTA employs specialized software algorithms to detect and follow the positions of individual nanoparticles across sequential frames of a video recording. Each particle's trajectory is constructed by linking its centroids frame-by-frame, typically requiring a minimum track length of several frames (e.g., 5–10) to filter noise and ensure reliable motion data. From these trajectories, the diffusion coefficient D is calculated for each particle by fitting the MSD versus time lag, often using linear regression on the initial linear portion of the curve to avoid biases from finite observation times or localization errors. NTA systems commonly track 100–1,000 particles simultaneously within the field of view over video durations of 30–60 seconds, aggregating data from multiple captures to achieve statistical robustness with thousands of total tracks per sample. The hydrodynamic radius r_h of each tracked particle is derived from its diffusion coefficient via the Stokes-Einstein relation: r_h = \frac{kT}{6\pi \eta D} Here, k is Boltzmann's constant ($1.38 \times 10^{-23} J/K), T is the absolute temperature in Kelvin, \eta is the dynamic viscosity of the suspending medium, and D is the particle-specific diffusion coefficient. This equation originates from equating the frictional drag force on a moving sphere in a viscous fluid, F = 6\pi \eta r_h v (Stokes' law), to the diffusive force in Fick's law, under the fluctuation-dissipation theorem, yielding the diffusion constant for translational Brownian motion. Key assumptions include particles behaving as rigid, non-interacting spheres with diameters much larger than solvent molecules, negligible inertial effects (overdamped regime), and accurate knowledge of temperature and viscosity; deviations, such as from non-spherical shapes or high concentrations, can introduce systematic errors in size estimates. Particles are visualized via light scattering to enable trajectory tracking.

Light Scattering Detection

In nanoparticle tracking analysis (NTA), elastic light scattering serves as the fundamental mechanism for rendering individual nanoparticles visible. A finely focused laser beam, typically operating at wavelengths between 405 nm and 640 nm, illuminates the sample suspension, causing nanoparticles to scatter light elastically without wavelength shift. For particles in the size range of 10-1000 nm, this scattering occurs primarily in the Rayleigh regime for smaller diameters (below approximately one-tenth of the wavelength) or the Mie regime for larger ones, where interference effects become prominent. The detection setup employs dark-field microscopy to isolate the scattered light from the incident beam, projecting bright particle images against a dark background for high contrast. In this configuration, the microscope objective collects the scattered light at an angle of approximately 90 degrees, while a charge-coupled device (CCD) or complementary metal-oxide-semiconductor (CMOS) camera records the trajectories. The intensity of the scattered light is directly proportional to the particle's size and its refractive index relative to the surrounding medium, enabling differentiation based on brightness; for instance, metallic nanoparticles like exhibit stronger scattering than polymeric ones of similar size due to higher refractive index contrasts. A core principle is the dependence of the scattering cross-section on particle dimensions, particularly in the Rayleigh regime where σ ∝ d^6 (with d as the diameter), making scattering intensity highly sensitive to size for sub-100 nm particles. This sixth-power relationship, however, imposes limitations for weakly scattering entities such as proteins or low-refractive-index biomolecules, which may evade detection despite being within the size range. Video acquisition occurs at frame rates of 30-60 frames per second, allowing real-time capture of particle motion over 30-60 seconds for subsequent tracking analysis. Particles smaller than approximately 30-50 nm are often not reliably detected due to insufficient scattering intensity, with the exact lower limit depending on the particle's material and refractive index relative to the medium (e.g., down to ~10 nm for ).

Instrumentation and Procedure

Key Components

The key components of nanoparticle tracking analysis (NTA) systems encompass hardware for precise illumination, imaging, and sample containment, integrated with software for particle motion analysis. These elements enable the visualization and quantification of nanoparticles through light scattering and motion tracking. Central to NTA hardware is the , which illuminates the sample chamber with a focused beam to generate scattered light from individual particles; common configurations include a 50 mW operating at 532 nm wavelength. The optical setup incorporates a with high numerical aperture (NA), typically 20x magnification, to maximize collection of the scattered light for high-resolution imaging. Detection relies on a high-sensitivity , such as an sCMOS or CCD/CMOS sensor, which records video sequences of particles undergoing at frame rates sufficient for real-time capture. The sample chamber, often designed as a flow cell or prism-coupled cell, holds the nanoparticle suspension in a thin layer (typically 250 µL volume) to align particles within the laser beam path and minimize multiple scattering. Proprietary software, exemplified by Malvern Panalytical's NTA suite, processes the video data using algorithms for real-time particle identification, trajectory linking, and least-squares fitting to model diffusion paths. Supporting accessories ensure measurement reliability, including temperature control modules that maintain sample conditions between 20–37°C to stabilize viscosity and motion dynamics, and dilution systems like syringe pumps for controlled sample delivery and flow rates up to 50 µL/min. Commercial NTA instruments, such as the from Malvern Panalytical (launched in 2023 with machine learning-powered analysis for enhanced precision), consolidate these components into a compact, automated platform capable of analyzing particles from 10 nm to 1 µm in diameter. By 2023, open-source alternatives like the and ImageJ-based plugins (e.g., ) had emerged for trajectory analysis and size estimation from similar video data.

Sample Preparation and Measurement

Sample preparation for nanoparticle tracking analysis (NTA) begins with diluting the nanoparticle suspension to an optimal concentration of 10^7 to 10^9 particles per mL to ensure sufficient particles are visible in the field of view without overcrowding, which could lead to tracking errors. This dilution is typically performed in a low-viscosity buffer such as phosphate-buffered saline (PBS) or 10 mM Tris-HCl (pH 7.5) to maintain particle stability and mimic physiological conditions where applicable, while avoiding high salt concentrations that may induce aggregation or alter electrophoretic mobility. To remove larger aggregates or contaminants exceeding 1 μm, which can interfere with accurate tracking of nanoparticles in the 10–1000 nm range, the sample is filtered using polycarbonate track-etched membranes (e.g., Nucleopore®) or subjected to low-speed centrifugation. Serial dilutions are recommended over single large steps (e.g., >200-fold) to prevent uneven particle distribution, and may be applied briefly if agglomeration is suspected, though care must be taken to avoid damaging delicate particles like exosomes. Once prepared, the sample—typically 300–500 μL—is loaded into the NTA instrument's sample chamber using a clean , often with a for controlled delivery in static or flow modes. The laser beam, which illuminates particles via light scattering for visualization, is focused to a depth of approximately 10 μm within the chamber to define the (roughly 100 μm × 80 μm × 10 μm). Measurement proceeds by recording 3–5 videos, each lasting 60 seconds, at multiple positions along the beam path to capture representative particle motion and improve statistical reliability; for low-concentration samples (<10^7 particles/mL), longer durations or additional videos may be needed. In flow mode, used particularly for assessment, a constant is set (e.g., such that particles remain in view for 5–10 seconds) via the , applying an across electrodes in the chamber to induce particle drift while tracking both Brownian and electrophoretic motion. Key instrumental parameters are adjusted prior to recording to optimize : is typically set to 30 frames per second for smooth tracking, exposure time to around 15 ms to balance brightness and , and power (e.g., 50–100 mW for a 405 nm or 532 nm source) increased gradually until particles are clearly visible without camera saturation. The entire measurement process, including setup and multiple recordings, usually takes 5–10 minutes per sample at (e.g., 22°C), with a 3-minute equilibration period after loading to stabilize and flow. Calibration is performed routinely using NIST-traceable 100 nm standards to verify size accuracy and concentration linearity before analyzing unknown samples.

Data Analysis and Interpretation

Size Distribution Calculation

In nanoparticle tracking analysis (NTA), the size distribution is derived from the of individual particles captured via light scattering and . Each particle's position is tracked over multiple frames, typically 30-100, to generate a . The (MSD) is then computed for each as the average of squared over various time lags, providing a measure of diffusive motion. For two-dimensional tracking, the MSD follows the relation: \langle \Delta r^2 \rangle = 4 D t where \langle \Delta r^2 \rangle is the , D is the diffusion coefficient, and t is the time lag. The diffusion coefficient D is extracted by performing a fit on the MSD versus time lag plot, with the slope yielding $4D. This assumes pure Brownian without drift or confinement, and fits are often limited to short time lags to minimize localization errors. The r_h for each particle is subsequently calculated using the Stokes-Einstein : D = \frac{k_B T}{6 \pi \eta r_h} where k_B is Boltzmann's constant, T is the absolute temperature, and \eta is the solvent viscosity. Individual particle sizes are thus obtained on a per-trajectory basis, enabling direct compilation into a number-weighted histogram by binning radii (e.g., in 10-50 nm intervals) to form the size distribution. Polydisperse samples, common in NTA applications, require advanced statistical methods beyond simple histogramming to resolve multimodal distributions accurately. Maximum likelihood estimation (MLE), often incorporating finite track length adjustments, optimizes parameter fits by accounting for trajectory incompleteness and bias in short tracks, improving resolution for overlapping peaks. Kernel density estimation (KDE) serves as an alternative, smoothing the empirical distribution of diffusion coefficients to estimate a continuous probability density without assuming bin widths, which is particularly useful for visualizing broad or skewed polydispersity. These approaches enhance precision for samples with size ranges spanning 10-1000 nm. Several error sources can affect size distribution accuracy. Trajectory linking errors arise from algorithmic challenges in connecting frames, such as when particles overlap or cross paths, leading to fragmented tracks and underestimated for affected particles. The projection of three-dimensional onto a two-dimensional focal plane introduces minor biases, as out-of-plane movement reduces apparent displacement, though this is negligible for sub-micrometer particles under typical shallow-depth . The lower is typically 20–50 nm, depending on the particle material and contrast, below which localization precision degrades due to and low signal-to-noise ratios, preventing reliable sizing of very small entities.

Concentration Determination

In nanoparticle tracking analysis (NTA), particle concentration is calculated by determining the average number of particles tracked across multiple video frames and dividing this count by the observation volume illuminated by the beam. The observation volume is defined by the beam's cross-sectional dimensions (typically width and height of the field of view) and the , which is governed by the optical configuration of the and focus, often on the order of 10-20 μm in depth. This yields an absolute concentration in units of particles per milliliter (particles/mL), as the technique directly enumerates individual particles without requiring standards. To ensure reliable measurements, samples are typically diluted to achieve optimal particle densities within the instrument's working range, with the final concentration adjusted by multiplying the measured value by the dilution factor. Multiple replicate measurements, such as several 60-second videos, are averaged to improve statistical robustness and reduce variability from particle or instrumental . In flow-assisted modes, such as those used for analysis, concentration values are normalized by the sample to account for the transit time of particles through the observation volume, ensuring that tracks are sufficiently long for accurate detection; recommended flow rates keep particles in the field of view for approximately 10 seconds to maintain precision. The accuracy of NTA concentration measurements is generally ±10-20% for samples in the range of 10^8 to 10^10 particles/mL, with lower limits around 10^7 particles/mL where insufficient particles may be tracked for statistical confidence, and upper limits near 10^10 particles/mL beyond which track overlapping reduces resolution. These limits depend on factors like particle polydispersity and contrast, but the method's single-particle resolution allows for direct counting even in complex suspensions. Unlike (DLS), which infers concentration indirectly from ensemble scattering intensity and often requires standards for absolute quantification, NTA provides true number-based concentrations as an inherent output of the tracking process.

Applications

In Biomedical Research

Nanoparticle tracking analysis (NTA) plays a pivotal role in characterizing extracellular vesicles (EVs), including exosomes, which typically range from 30 to 150 in size and are analyzed for their concentration and size distribution in biomedical contexts. NTA enables precise quantification of these bio-nanoparticles, facilitating their identification as potential biomarkers, particularly in cancer diagnostics where elevated exosome levels in correlate with tumor progression. For instance, studies have utilized NTA to measure exosome concentrations in patient , revealing diagnostic signatures for with improved sensitivity when combined with protein markers. This technique's ability to handle polydisperse biological samples provides advantages over for such applications. NTA is endorsed as a standard method for EV research in the Minimal Information for Studies of Extracellular Vesicles (MISEV) guidelines, first outlined in 2018 and updated in 2023 to emphasize robust protocols including size and concentration measurements. Recent investigations from 2024 and 2025 have applied NTA to plasma-derived EVs, demonstrating its utility in isolating and quantifying vesicles for proteomic analysis and in conditions like wounds and cardiovascular diseases. These advancements underscore NTA's integration into clinical workflows for non-invasive liquid biopsies. In , NTA has been instrumental for quantifying viral particles during the 2020s pandemic, with studies employing it to assess inactivated virion concentrations and diameters in complex matrices like supernatants. This approach extended to development, where NTA characterized nanoparticle-based delivery systems, such as nanoparticles in mRNA vaccines, ensuring uniform size distribution for optimal and stability. For applications, NTA evaluates liposomes, which serve as carriers for therapeutics, by tracking their to determine size and concentration without disrupting encapsulation. In protein therapeutics, NTA detects aggregates that could compromise efficacy or safety, with analyses showing it complements other methods for monitoring subvisible particles in formulations like monoclonal antibodies.

In Nanotechnology and Materials Science

In and , nanoparticle tracking analysis (NTA) plays a crucial role in characterizing synthetic nanoparticles, enabling precise assessment of size distributions, concentrations, and in suspensions. This single-particle excels at analyzing polydisperse samples, providing insights into aggregation and behaviors that are essential for and process optimization. Unlike ensemble methods such as , NTA's ability to track individual particles offers superior resolution for heterogeneous , facilitating and performance evaluation in industrial applications. NTA is widely applied for sizing and monitoring aggregation of colloidal and nanoparticles, particularly in formulations like paints and inks where pigment stability directly impacts product quality. For instance, nanoparticles in inks and paints have been characterized using NTA to determine size distributions and detect aggregation, ensuring uniform dispersion and preventing settling during manufacturing. In polymer colloids, such as or thermoresponsive poly(N-isopropylacrylamide) (PNIPAM), NTA measures hydrodynamic diameters and concentrations, revealing temperature-induced aggregation shifts that inform stability for coating applications. These analyses support by quantifying particle loading efficiency in formulations like polymersomes. Environmental monitoring benefits significantly from NTA's sensitivity to nanoplastics and metal oxides in and terrestrial matrices. For plastic micro- and nanoparticles in , NTA detects sizes from 46 to over 350 with concentrations ranging from 5.0 × 10⁶ to 2.0 × 10⁹ particles/mL, as validated in bottled samples showing 1.0 × 10⁶ to 2.2 × 10⁷ particles/mL with mean sizes of 110-170 . This aligns with the 's 2022 microplastics restriction proposals, leading to Regulation () 2023/2055, which bans intentional addition of synthetic polymer microparticles to curb environmental release and necessitates robust detection methods for compliance. In soils, NTA assesses metal oxide nanoparticles (e.g., TiO₂, ZnO) by distinguishing them from natural particulates based on differences, enabling quantification of transport and in complex environmental samples. NTA also evaluates real-time stability of quantum dots and catalyst nanoparticles in suspensions, critical for optoelectronic and chemical processing applications. For quantum dots like CdSe/ZnS nanocrystals and catalyst nanoparticles (e.g., metal oxides in suspensions), NTA monitors stability post-drying and re-suspension, detecting concentrations up to 10¹² particles/mL without interference. In 2024 studies on , NTA characterized polydisperse environmental samples for exposure assessments, highlighting its edge over techniques in resolving size heterogeneity for risk evaluation.

Comparisons with Alternative Techniques

Versus Dynamic Light Scattering

Dynamic light scattering (DLS) is an ensemble averaging technique that determines nanoparticle size by analyzing the function of intensity fluctuations in scattered light caused by of particles in suspension. It typically provides an intensity-weighted average hydrodynamic diameter and assumes samples are largely monodisperse for optimal accuracy, with a measurable size range of approximately 1–1000 . In contrast, nanoparticle tracking analysis (NTA) employs single-particle tracking to measure the trajectories of individual nanoparticles via light scattering, enabling direct resolution of size distributions from 10–1000 and providing number-based concentrations without relying on ensemble averages. While DLS is biased toward larger particles due to its sixth-power dependence on particle diameter in scattering intensity, NTA offers unbiased number distributions, making it superior for resolving polydispersity in heterogeneous samples. NTA's advantages include direct of particles, accurate of polydisperse mixtures, and of particle counts, though it is slower (typically 1–5 minutes per measurement) and requires dilute samples (10^7–10^9 particles/mL) for reliable tracking. DLS, conversely, excels in speed (under 1 minute), automation, and reproducibility for monodisperse or narrowly distributed samples but lacks and often overestimates sizes in mixtures due to dominance by larger aggregates. Validation studies have demonstrated NTA's greater accuracy for polydisperse mixtures; for instance, in analyzing bimodal bead mixtures (e.g., 60/100 nm and 100/400 nm at varying ratios up to 300:1), NTA resolved distinct peaks while DLS merged them into a single shifted average. Similarly, in 2022 evaluations of nanoparticle-extracellular vesicle complexes, NTA effectively deconvoluted binding states in polydisperse systems, outperforming DLS's ensemble Z-average. DLS assesses polydispersity via cumulants analysis, yielding a polydispersity index (PDI) from the second of the function, whereas NTA derives distributions directly from individual tracks without such assumptions.

Versus Electron Microscopy and Others

Nanoparticle tracking analysis (NTA) differs fundamentally from electron microscopy techniques such as transmission electron microscopy (TEM) and scanning electron microscopy (SEM), which provide high-resolution imaging of individual nanoparticles in a dried state under vacuum conditions. TEM and SEM achieve resolutions down to 1 nm, enabling detailed morphological analysis of particles from 1 to 100 nm, but require sample preparation that involves drying and often staining or coating, which can introduce artifacts like shrinkage or aggregation. In contrast, NTA analyzes nanoparticles in their native liquid suspension, offering non-destructive, real-time tracking without such preparation-induced distortions. Validation studies on extracellular vesicles (EVs) demonstrate that NTA correlates well with TEM for distributions, typically reporting modes of 70–160 , though it tends to overestimate diameters by 80–200% due to its reliance on measurements, while TEM may underestimate by up to 21% from drying shrinkage. However, NTA excels in throughput and concentration quantification, processing thousands of particles per minute to yield counts of 10^8–10^10 particles/mL for EVs, whereas TEM's manual counting limits it to hundreds of particles per sample and provides no direct concentration data without additional sedimentation assays. This makes NTA particularly advantageous for high-volume liquid-phase , avoiding the destructive nature of . Beyond electron microscopy, NTA contrasts with , which is suited for fluorescence-labeled particles larger than 100–200 and requires specific markers for identification, limiting its use to subpopulations rather than total counts in . (AFM), meanwhile, offers sub-nanometer resolution for surface topography but is restricted to adsorbed, dried samples on substrates, making it slow and unsuitable for bulk analysis, with measurements taking hours per sample compared to NTA's minutes. Overall, while NTA sacrifices the ultrahigh of TEM/ or AFM for lower (typically 10–20% variability in size), it complements these methods by enabling , liquid-phase evaluation of size distributions and concentrations, which electron microscopy and surface-bound techniques cannot provide without extensive adaptation. For instance, in research, NTA's ability to handle dilute, native samples without drying artifacts positions it as a high-throughput orthogonal tool to methods.

Advanced Variants and Recent Advances

Interferometric NTA (iNTA)

Interferometric nanoparticle tracking analysis (iNTA) is an advanced variant of nanoparticle tracking analysis that integrates (iSCAT) microscopy to enable the detection and characterization of weakly nanoparticles, such as proteins and extracellular vesicles (EVs). By leveraging between the light scattered by individual particles and a reference beam, iNTA achieves high signal-to-noise ratios for particles that are challenging for conventional NTA, allowing simultaneous determination of and from their Brownian trajectories and signals. This method builds on standard NTA by incorporating iSCAT to enhance sensitivity for sub-30 nm objects. Key advancements in iNTA include the independent measurement of and material-specific , which facilitates the differentiation of particle compositions in polydisperse mixtures without prior calibration. It extends detection limits to approximately 10 nm for high-contrast particles like gold nanoparticles, surpassing conventional NTA's typical threshold of 30 nm for gold or 60 nm for , and provides precision comparable to for size distributions. These improvements enable the analysis of complex biological samples, such as distinguishing EVs from lipoproteins based on their distinct refractive indices (e.g., EVs around 1.4 versus lipoproteins near 1.45). In 2024, iNTA was further applied to quantify concentrations in plasma-derived samples, achieving absolute counts in the range of 10⁸–10¹¹ particles/mL with less than 5% misclassification in EV-lipoprotein separations. Implementation of iNTA involves modifying a standard NTA setup with a wide-field iSCAT configuration, where a is added to generate between the particle-scattered light and a reference reflection from the coverslip. A illuminates the sample, and the resulting patterns are captured by a high-speed camera (e.g., at 5,000 frames per second), enabling trajectory tracking via analysis. Software then fits the amplitude and phase of the scattering signals to extract diffusion constants and scattering cross-sections, yielding via the Stokes-Einstein relation D = \frac{k_B T}{3\pi \eta d} and from the scattering . For scatterers, the \alpha, which determines the scattering , is given by \alpha = 3V \left( \frac{n_p^2 - n_m^2}{n_p^2 + 2n_m^2} \right), where V is the particle volume, n_p the particle refractive index, and n_m the medium refractive index, with the scattering cross-section \sigma_{sca} \propto |\alpha|^2. iNTA was first introduced in 2022 by Kashkanova et al.

Emerging Techniques

Fluorescence nanoparticle tracking analysis (fNTA) has emerged as a key extension of conventional NTA, enabling the identification of specific subpopulations within heterogeneous nanoparticle samples through fluorescent labeling. By incorporating dyes such as Di-8-ANEPPS to target lipid membranes, fNTA facilitates the visualization and quantification of extracellular vesicles (EVs), including those expressing markers like CD63, which co-localize with endosomal compartments. Machine learning enhancements are increasingly integrated into NTA workflows to improve data quality and analysis in challenging samples. Unsupervised deep learning algorithms applied to nanoparticle scattering data enable effective trajectory denoising, reducing noise floors and enhancing the detection of rare or low-signal particles in polydisperse mixtures. In 2025 studies, AI-driven methods have been developed for anomaly detection, segmenting overlapping trajectories and identifying aberrant motion patterns, which aids in distinguishing subpopulations in noisy datasets from environmental or biological sources. Hybrid systems combining NTA with complementary techniques are advancing multimodal characterization of nanoparticles. Building on foundational advances like interferometric NTA, 2022 research has applied statistical mixture analysis to NTA data for quantifying nanoparticle-vesicle interactions, particularly in low-concentration regimes where traditional methods struggle with . This approach deconvolves binding distributions across vesicle types, providing quantitative insights into extents and addressing detection limits below 10^8 particles/mL.

References

  1. [1]
    Critical Evaluation of Nanoparticle Tracking Analysis (NTA) by ... - NIH
    NTA is very accurate for sizing both monodisperse and polydisperse samples and has a substantially better peak resolution. The presence of few large particles ...
  2. [2]
    Nanoparticle Tracking Analysis (NTA) - Malvern Panalytical
    Nanoparticle Tracking Analysis (NTA) utilizes the properties of both light scattering and Brownian motion in order to obtain the nanoparticle size distribution ...
  3. [3]
    [PDF] Introduction to Nanoparticle Tracking Analysis (NTA)
    Nanoparticle Tracking Analysis (NTA) visualizes and measures nanoparticles (10-1000 nm) by analyzing Brownian motion using a video sequence.
  4. [4]
    Validation of Size Estimation of Nanoparticle Tracking Analysis on ...
    Feb 25, 2019 · In this study, we evaluated two NTA data analysis methods based on maximum-likelihood estimation, namely finite track length adjustment (FTLA) and an iterative ...
  5. [5]
    Nanoparticle Tracking Analysis: An Effective Tool to Characterize ...
    Oct 1, 2024 · Nanoparticle tracking analysis (NTA) offers distinct benefits for EV characterization. In this review, we will discuss the NTA technique with a focus on ...
  6. [6]
    A Review of the use of Nanoparticle Tracking Analysis (NTA)
    Mar 11, 2014 · This white paper describes the central role of high resolution particle size and concentration measurements in nanoparticle research.Missing: original | Show results with:original
  7. [7]
    Nanoparticle Tracking Analysis for the Quantification and Size ...
    The particle tracking instrument characterizes nanoparticles in liquid samples by analyzing their Brownian motion and characterizes larger micron-sized ...
  8. [8]
    Company Profile: NanoSight: delivering practical... : Nanomedicine
    What is nanoparticle tracking analysis? Open multimedia modal. (A) Video of light scattering from individual particles. (B) Tracks of individual particles ...<|control11|><|separator|>
  9. [9]
    World-Leading Nanoparticle Characterization - AZoNano
    Nov 6, 2012 · NanoSight's “Nanoparticle Tracking Analysis” (NTA) detects and visualizes populations of nanoparticles in liquids down to 10 nm, dependent on ...
  10. [10]
    Nanoparticle tracking analysis monitors microvesicle and exosome ...
    Hence, NTA can be used to detect increases in the levels of secretion of exosomes and microvesicles upon stimulation of a variety of cells of the immune system.
  11. [11]
    NanoSight Limited Announces the Launch of the NS300 Providing a ...
    Mar 5, 2013 · Salisbury, UK, 5th March 2013: NanoSight reports on the new NS300 system based on their Nanoparticle Tracking Analysis technology.
  12. [12]
    NanoSight acquired by Malvern Instruments - Optics.org
    Sep 30, 2013 · Date Announced: 30 Sep 2013. UK firm buys into optics-based nanoparticle tracking technology. Amesbury, UK, 30th September, 2013: NanoSight ...
  13. [13]
    NanoSight NTA software update v3.44 - Malvern Panalytical
    NanoSight NTA software update v3.44. Version number: 3.44. Release date: 05 October 2020. Operating system: Windows 7 Windows 10. Language: English.Missing: polydispersity | Show results with:polydispersity
  14. [14]
    Precision size and refractive index analysis of weakly scattering ...
    May 9, 2022 · Here we introduce iNTA as a new method that combines interferometric detection of scattering with nanoparticle tracking analysis to reach unprecedented ...
  15. [15]
  16. [16]
  17. [17]
    NanoSight Pro - Nanoparticle Analyzer - Malvern Panalytical
    Inventor of NTA technology ...<|control11|><|separator|>
  18. [18]
    NanoSight NS300 | Characterize Nanoparticles - Malvern Panalytical
    The NS300 allows rapid, automated analysis of the size distribution and concentration of all types of nanoparticles from 0.01 - 1 µm* in diameter, depending on ...
  19. [19]
    Nanoparticle Tracking Analysis English - BRAVE Analytics
    By using the Stokes-Einstein-equation the hydrodynamic diameter of single particles can be calculated and the particle size, particle size distribution and ...
  20. [20]
    Fast, Flexible Particle-Tracking Toolkit — trackpy 0.7 - Soft Matter
    Trackpy is a Python package for particle tracking in 2D, 3D, and higher dimensions. For a brief introduction to the ideas behind the package, ...
  21. [21]
    NanoTrackJ
    NanoTrackJ analyzes videos of diffusing particles, mainly nanoparticles, to estimate particle size and diffusion coefficient distribution.
  22. [22]
  23. [23]
    [PDF] Nanoparticle Tracking Analysis_Mar2015 - University of Florida
    The ability of this technique to simultaneously analyze a population of nanoparticles on an individual basis means it is ideally suited for the real-time ...
  24. [24]
    Basic Principles of Nanoparticle Tracking Analysis - Q&A
    Aug 24, 2017 · Is dilution needed in sample preparation? Dilution will most likely be required unless you have a sample that is very sparse to begin with.
  25. [25]
    Zeta Potential Analysis using Z-NTA (Zeta Potential Nanoparticle ...
    Sep 25, 2012 · This technical note describes Zeta Potential Nanoparticle Tracking Analysis (Z-NTA), which adds the measurement of electrostatic potential to simultaneous ...Missing: mode | Show results with:mode
  26. [26]
    NanoSight Pro size distribution analysis – FTLA or Raw?
    Oct 15, 2024 · This technical note explores two methods for plotting distribution data with NanoSight Pro, aimed at enhancing confidence in the analysis of polydisperse ...
  27. [27]
    [PDF] Maximum Likelihood Estimation for the Improved Nanoparticle ...
    4Dt. ,-с <x< с. (2.8) where, D is the diffusion coefficient. The detailed ... Particle Tracking Analysis or Nanoparticle Tracking Analysis (NTA) is one of the.
  28. [28]
    Analysis and correction of errors in nanoscale particle tracking using ...
    We have demonstrated the pixel-locking error that is inherent to tracking of nanoscale objects such as nanoparticles, quantum dots and fluorescent single ...Missing: projection | Show results with:projection
  29. [29]
    None
    - **Definition of NTA**: Nanoparticle Tracking Analysis (NTA) visualizes and sizes nanoparticles in liquid suspension by tracking their Brownian motion.
  30. [30]
    NTA accuracy and repeatability with flow mode measurements
    Precision and repeatability of concentration measurements are significantly improved when a slow flow is imparted on the sample.
  31. [31]
  32. [32]
    Real-time nanoparticle detection and analysis on a particle ... - SPIE
    Jul 22, 2009 · NanoSight Ltd. Bob Carr has a PhD in microbial biochemistry and is founder of NanoSight.Missing: invention | Show results with:invention
  33. [33]
  34. [34]
    Effects of ionic strength, electrolyte type, and natural organic matter
    Aug 6, 2025 · Our findings demonstrated the colloidal stability of QDs and cations-NOM-QD nanoparticle complexes under a broad spectrum of conditions ...<|separator|>
  35. [35]
  36. [36]
  37. [37]
  38. [38]
    A direct comparison of experimental methods to measure ...
    The results indicate that in general, scanning electron microscopy is suitable for large nanoparticles (above 50 nm in diameter), while AFM and TEM can also ...
  39. [39]
    Extracellular vesicle measurements with nanoparticle tracking analysis
    Accordingly, the major difference of ExoView to TEM and Nanoparticle tracking analysis (NTA) is that ExoView analyses particles selectively, based on the ...
  40. [40]
    Direct comparison of optical and electron microscopy methods for ...
    Apr 1, 2020 · Comparison of cryo-TEM and NTA in extracellular vesicle expression and diameter distributions. Results from both conventional and cryo-SEM ...
  41. [41]
    Extracellular vesicle sizing and enumeration by nanoparticle ...
    Nanoparticle tracking analysis (NTA) is a light-scattering technique that is useful for the rapid sizing and enumeration of extracellular vesicles (EVs).
  42. [42]
    Measuring Nanoparticle Concentration in Polydisperse Mixtures
    Jul 9, 2024 · Recently, we introduced interferometric nanoparticle tracking analysis (iNTA) for high-precision measurement of nanoparticle size and refractive ...
  43. [43]
    Extracellular vesicles from the microalga Tetraselmis chuii ... - Nature
    Aug 3, 2024 · Fluorescence nanoparticle tracking analysis (F-NTA). The Fluorescence nanoparticle tracking analysis (F-NTA) was carried out as describe in ...
  44. [44]
    Single Extracellular VEsicle Nanoscopy-Universal Protocol (SEVEN ...
    Jan 13, 2025 · ... fluorescence nanoparticle tracking analysis (NTA) measurements which ... multicolor imaging setting. Figure 3. Figure 3. Validation of ...
  45. [45]
    High throughput analysis of rare nanoparticles with deep-enhanced ...
    20 Feb 2025 · This denoising approach allows us to push down the noise floor and increase the separation between particle peaks and noise, ultimately enabling ...
  46. [46]
    An ultra-compact particle size analyser using a CMOS image sensor ...
    Feb 12, 2020 · In this paper, we introduce the concept of a new particle size analyser in a collimated beam configuration using a consumer electronic camera and machine ...
  47. [47]
    Nanoparticle tracking analysis and statistical mixture distribution ...
    The mean squared displacement in the x–y plane is used to calculate translational diffusion coefficients (DT) for individual particles, yielding a number ...