Fact-checked by Grok 2 weeks ago

Permanganometry

Permanganometry is a technique utilized in to determine the concentration of reducing agents in a sample by employing a standardized solution of (KMnO₄) as the titrant. The method exploits the strong oxidizing properties of the (MnO₄⁻), which is reduced to the nearly colorless manganese(II) (Mn²⁺) in an acidic medium, following the MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O. This process requires an acidic environment, typically provided by , to ensure the proceeds quantitatively and to prevent the formation of precipitates. The in permanganometry is self-indicating, as the solution remains colorless until excess produces a persistent or hue, eliminating the need for an external indicator. of the KMnO₄ solution is essential due to its instability over time and is commonly achieved by titrating against primary standards such as (Na₂C₂O₄) in hot acidic conditions, where the reaction is 2MnO₄⁻ + 5C₂O₄²⁻ + 16H⁺ → 2Mn²⁺ + 10CO₂ + 8H₂O. To prepare a stable solution, KMnO₄ is often boiled and filtered to remove impurities, yielding a concentration that remains reliable for 1–2 weeks. Permanganometry finds widespread application in for analytes including iron(II) ions (via MnO₄⁻ + 5Fe²⁺ + 8H⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O), oxalates, ascorbic acid, and in water samples. It is particularly valued in and pharmaceutical analysis. Despite its advantages, such as high precision and the absence of indicator interference, the method's sensitivity to , , and organic impurities can introduce errors if not managed carefully.

Introduction

Definition and Principles

Permanganometry is a quantitative analytical method involving the titration of reducing agents with potassium permanganate (KMnO₄) solutions through redox reactions. This technique serves as a subset of redox titrations within volumetric analysis, where the volume of titrant consumed provides a measure of the analyte's concentration based on stoichiometric electron transfer. The fundamental principles of permanganometry rely on oxidation-reduction processes in which the (MnO₄⁻) functions as a strong . In acidic medium, MnO₄⁻ is reduced to Mn²⁺, involving the gain of five electrons per permanganate ion, which establishes an n-factor of 5 for KMnO₄ under these conditions. The general governing this reduction is: \ce{MnO4^- + 8H^+ + 5e^- -> Mn^{2+} + 4H2O} This reaction proceeds with a standard of approximately 1.51 V, highlighting the potency of as an oxidant. The in permanganometric titrations is detected visually by the distinct color change from the intense of excess MnO₄⁻ to the pale or colorless solution dominated by Mn²⁺, eliminating the need for an external indicator. This self-indicating property enhances the method's simplicity and accuracy in quantitative determinations.

Historical Development

Permanganometry was introduced in 1846 by the French chemist Frédéric Margueritte as a volumetric analysis method employing potassium permanganate for the determination of iron content. This innovation built on earlier redox principles and marked the first systematic use of permanganate as a titrant in acidic media, initially applied to iron ores and alloys. Margueritte's approach utilized the distinctive pink color of permanganate as a self-indicator, enabling endpoint detection without external indicators. The technique gained prominence in the mid-19th century, particularly for iron assays, with significant refinements by analysts such as Karl Remigius Fresenius in 1862. Fresenius demonstrated inaccuracies in Margueritte's original method when using due to evolution and recommended to enhance stability and accuracy. Further contributions included Friedrich Mohr's 1855 applications to organic compounds like and Armand Bussy's 1847 titration of arsenious acid, solidifying permanganometry's role in . Standardization protocols were established in the late , notably through Volhard's 1879 improvements for determination. By the early , permanganometry had been incorporated into pharmacopeias and standard analytical compendia, reflecting its reliability for pharmaceutical and industrial assays. Post-1950s adaptations extended its use to environmental monitoring, such as the permanganate index for assessing water oxidizability under European directives. The method evolved from rudimentary qualitative color tests to precise quantitative titrations, driven by advances in preparing acid-stable solutions that minimized . These developments, including potentiometric endpoints introduced by Karl Crotogino in 1900, enhanced accuracy and broadened applicability across .

Chemical Basis

Redox Reactions of Permanganate

The ion (MnO₄⁻) serves as a versatile in titrations, with its reduction behavior varying by medium. In acidic conditions, it undergoes a five-electron reduction to manganese(II) ions, represented by the : \ce{MnO4^- + 8H+ + 5e^- -> Mn^{2+} + 4H2O} This process has a standard reduction potential of +1.51 V, making it a strong oxidant suitable for titrating robust reductants such as Fe²⁺. A representative balanced redox reaction in acidic medium involves iron(II) ions, where the oxidation half-reaction is \ce{Fe^{2+} -> Fe^{3+} + e^-}. Combining these yields the overall equation: \ce{5Fe^{2+} + MnO4^- + 8H+ -> 5Fe^{3+} + Mn^{2+} + 4H2O} This stoichiometry reflects the five-electron transfer per permanganate ion. Another common example is the oxidation of oxalate ions (C₂O₄²⁻) to carbon dioxide in acidic medium, where each oxalate loses two electrons (\ce{C2O4^{2-} -> 2CO2 + 2e^-}). The balanced equation is: \ce{5C2O4^{2-} + 2MnO4^- + 16H+ -> 10CO2 + 2Mn^{2+} + 8H2O} Here, two permanganate ions accept ten electrons total, consistent with the five-electron reduction per MnO₄⁻. In neutral or alkaline media, permanganate reduces to manganese(IV) oxide (MnO₂) via a three-electron process: \ce{MnO4^- + 2H2O + 3e^- -> MnO2 + 4OH^-} The standard reduction potential for this half-reaction is +0.60 V, rendering it a milder oxidant appropriate for less reactive reductants. The n-factor, or number of electrons transferred per mole of permanganate, is crucial for stoichiometric calculations in permanganometry. In acidic medium, n = 5 due to the full reduction to Mn²⁺, while in neutral or alkaline medium, n = 3 for the formation of MnO₂. This difference dictates the equivalence point ratios and solution volumes in titrations.

Medium and Conditions

Permanganometry titrations are conducted primarily in an acidic medium to ensure the permanganate ion undergoes complete reduction to the manganese(II) ion, preventing partial reduction products like manganese dioxide that could form under neutral or basic conditions. Dilute sulfuric acid, at concentrations of approximately 1 to 2 M, is the standard choice for acidification, as it provides the necessary hydrogen ions while remaining stable against oxidation by permanganate. Hydrochloric acid is unsuitable due to the oxidation of chloride ions to chlorine gas, which consumes permanganate and leads to inaccurate endpoints. Temperature plays a critical role in controlling reaction kinetics, especially for analytes with slow reaction rates, such as oxalates. At , these reactions proceed sluggishly, often requiring heating to 60–80 °C to accelerate the oxidation process sufficiently for practical times. This controlled heating avoids excessive temperatures that could induce permanganate decomposition or side reactions. The inherent color of makes it a self-indicator, with the solution remaining nearly colorless as is reduced to (II) ions, which are nearly colorless in acidic solution. The is indicated by the appearance and persistence of a pale pink hue from a slight excess of titrant, achieving maximum sharpness under conditions of excess acid, minimizing fading and ensuring precise detection. Potassium permanganate solutions exhibit instability, decomposing gradually in light or heat to form manganese dioxide and release oxygen, which reduces their oxidizing power over time. Storage in amber or opaque bottles, protected from direct light and maintained at cool temperatures, is essential to preserve solution integrity. Interfering substances, particularly organic compounds, can further complicate titrations by promoting the formation of colloidal manganese dioxide instead of soluble manganese(II), necessitating sample pretreatment to remove such reductants.

Preparation and Standardization

Preparation of Solutions

The preparation of (KMnO₄) solution for permanganometry begins with dissolving approximately 3.2 g of analytical-grade KMnO₄ in 1 L of to achieve an approximate 0.02 M concentration. The solution is then heated on a bath for about 1 hour or boiled for 15 minutes to oxidize and remove any organic impurities present in the or reagent, followed by cooling and filtration while hot through glass wool to eliminate precipitates. Due to the instability of KMnO₄ and potential impurities in commercial samples, direct weighing does not yield an exact molarity, necessitating subsequent . Supporting reagents essential for permanganometric titrations include 2 M sulfuric acid (H₂SO₄), which is prepared by cautiously adding approximately 111 mL of concentrated H₂SO₄ (≈18 M) to distilled water and diluting to 1 L while stirring and cooling to manage the exothermic reaction. Standard 0.1 N oxalic acid (H₂C₂O₄·2H₂O) solution, used as a primary standard for verification, is made by dissolving 6.3 g of the dihydrate in 1 L of distilled water. For titrations involving ferrous iron (Fe²⁺), the Zimmerman-Reinhardt solution is prepared to prevent air oxidation of Fe²⁺; this involves dissolving 70 g of manganese(II) sulfate tetrahydrate (MnSO₄·4H₂O) in 500 mL of water, then adding 125 mL of concentrated H₂SO₄ and 125 mL of 85% phosphoric acid (H₃PO₄), and diluting to 1 L. Purity is critical, particularly for KMnO₄, where analytical-grade crystals free from reducing contaminants should be used to minimize initial decomposition. All reagents must be handled with care, as KMnO₄ solutions can decompose upon exposure to light, heat, or , reducing their oxidizing power over time. Prepared KMnO₄ solutions should be stored in dark, amber-colored bottles in a cool place away from light and reducing agents to preserve , with a typical of 1-2 weeks before re-standardization is required.

Standardization Methods

Standardization of (KMnO₄) solutions in permanganometry requires the use of s to establish their exact concentration, as KMnO₄ is not itself a due to its instability in solution. The preferred s are (Na₂C₂O₄) or dihydrate (H₂C₂O₄·2H₂O), selected for their high purity, chemical stability under storage conditions, and availability as from organizations like the National Institute of Standards and Technology (NIST). These standards react quantitatively with permanganate in acidic medium via the process where oxalate is oxidized to , allowing precise determination of the titrant's . The standard procedure for standardization using involves preparing a 0.1 N solution by dissolving approximately 0.63 g of the dihydrate in and diluting to 100 mL. A 25 mL of this solution is transferred to a 250 mL , followed by the addition of 10 mL of concentrated (H₂SO₄) to provide the acidic medium. The mixture is heated to 80–90°C on a or water bath (avoiding boiling to prevent decomposition) and then titrated with the KMnO₄ solution from a . The endpoint is reached when a faint pink color, due to excess , persists for at least 30 seconds after swirling; no external indicator is needed owing to the intense color of MnO₄⁻. Multiple trials (typically three) are performed to ensure reproducibility, with the solution maintained hot throughout the to accelerate the reaction and minimize errors from slow kinetics at lower temperatures. Calculations for the molarity of the KMnO₄ solution are based on the stoichiometry of the reaction, where each mole of MnO₄⁻ accepts 5 electrons (n-factor = 5) in acidic medium to form Mn²⁺. The formula is: M_{\ce{KMnO4}} = \frac{N_{\ce{oxalic}} \times V_{\ce{oxalic}}}{5 \times V_{\ce{KMnO4}}} Here, N_{\ce{oxalic}} is the normality of the (equivalent to twice its molarity, as oxalic acid has an n-factor of 2), V_{\ce{oxalic}} is the volume of oxalic acid used in liters, and V_{\ce{KMnO4}} is the volume of KMnO₄ titrant in liters. This yields the exact molarity, enabling accurate subsequent analyses. An alternative standardization method employs (As₂O₃) as the primary standard. Approximately 0.15–0.20 g of dried As₂O₃ is weighed and dissolved in 20 mL of 1 M to form sodium , then diluted with 150 mL of and acidified with 10 mL of concentrated (HCl). Add 2–4 drops of 0.001 M (KIO₃) solution to catalyze the reaction, and titrate directly with the KMnO₄ solution until a faint pink color persists for at least 30 seconds. The concentration is calculated from the , where the n-factor for As₂O₃ is 4 (As from +3 to +5, 2 electrons per As atom). This method is less commonly used due to the of arsenic compounds but provides high accuracy. KMnO₄ solutions are prone to decomposition through reduction to (MnO₂) when exposed to , heat, airborne contaminants, or organic impurities, leading to a gradual decrease in oxidizing power. To ensure reliability, must be performed daily or immediately prior to use, particularly in settings where solutions are stored in containers. Proper storage in bottles away from can extend usability, but routine verification remains essential for quantitative work.

Analytical Procedures

Direct Permanganometry

Direct permanganometry involves the direct titration of a reducing analyte with a standardized potassium permanganate (KMnO₄) solution in an acidic medium, where the permanganate acts as the oxidizing titrant. The process begins with the setup of the analyte solution: a known volume of the sample containing the reductant, such as a ferrous iron (Fe²⁺) solution, is pipetted into an Erlenmeyer flask (typically 10.00 mL using a volumetric pipet), followed by the addition of excess sulfuric acid (H₂SO₄, approximately 10 mL of 1 M solution) to maintain an acidic environment and prevent hydrolysis of the permanganate. If necessary, the solution may be diluted with distilled water to ensure clear visibility during titration. The titration proceeds by filling a burette with the standardized KMnO₄ solution and recording the initial volume to 0.01 mL precision, using the upper meniscus due to the solution's intense color. The analyte flask is then titrated at room temperature (or slightly heated if required for the specific reductant), with continuous swirling to ensure complete mixing and rapid reaction. The endpoint is reached when a permanent pale pink color appears upon addition of the first drop of excess KMnO₄, typically corresponding to about 0.5–1 mL surplus titrant, as the purple permanganate color persists without fading. No external indicator is needed, as the permanganate itself serves this role; the final burette volume is recorded, and the titration is repeated for concordance within 0.20 mL. The concentration of the is calculated using the of the reaction, where the n-factor (number of electrons transferred) for KMnO₄ in acidic medium is 5 (MnO₄⁻ to Mn²⁺), while for reductants like Fe²⁺ it is 1 (Fe²⁺ to Fe³⁺). For example, the percentage of iron in an sample can be determined from the balanced MnO₄⁻ + 5Fe²⁺ + 8H⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O, yielding the formula: % Fe = [5 × M_{KMnO_4} × V_{KMnO_4} × 55.845 × 100] / (1000 × mass of sample), where M_{KMnO_4} is the molarity of the titrant and V_{KMnO_4} is the volume in mL. More generally, moles of = 5 × (M_{KMnO_4} × V_{KMnO_4} / 1000), followed by conversion to using the weight (55.845 g/mol for ). The KMnO₄ solution must be standardized beforehand using methods such as against . Key precautions include performing the titration promptly to minimize auto-oxidation of air-sensitive reductants like Fe²⁺, which can occur upon exposure to oxygen, and ensuring the solution remains acidic throughout to avoid precipitation of (MnO₂). This method is suitable for stable reducing agents such as Fe²⁺ that react quantitatively and instantaneously with under these conditions.

Indirect Permanganometry

Indirect permanganometry employs a back-titration approach in which a known excess of standardized potassium permanganate (KMnO₄) solution is added to the analyte in an acidic medium, allowing complete reaction with the reducing analyte. The unreacted permanganate is then quantified by titration with a standard reducing agent, such as oxalic acid (H₂C₂O₄) or ferrous ammonium sulfate (Mohr's salt, Fe(NH₄)₂(SO₄)₂·6H₂O), using the disappearance of the permanganate color (solution becomes colorless) as the endpoint. This method ensures accurate determination when direct titration is impractical due to slow reaction kinetics or interference. In a typical , the sample is dissolved and acidified with (H₂SO₄) to maintain an acidic environment (pH ≈ 1–2), followed by addition of a measured excess of 0.1 N KMnO₄ . The mixture is heated to 60–80°C if required to facilitate the reaction, then cooled, and the surplus is back-titrated with 0.1 N or ferrous while stirring vigorously. The is indicated by the disappearance of the permanganate color (the becomes colorless). For the determination of manganese(II) (Mn²⁺), a permanganate variant involves initial oxidation of Mn²⁺ to manganese dioxide (MnO₂) using ammonium persulfate ((NH₄)₂S₂O₈) in the presence of a silver nitrate (AgNO₃) catalyst under acidic conditions. The resulting MnO₂ precipitate is then treated with excess standard ferrous sulfate (FeSO₄), which reduces MnO₂ back to Mn²⁺ according to the reaction: \text{MnO}_2 + 4\text{H}^+ + 2\text{Fe}^{2+} \rightarrow \text{Mn}^{2+} + 2\text{Fe}^{3+} + 2\text{H}_2\text{O} The unreacted Fe²⁺ is subsequently titrated with standard KMnO₄ solution. This reverse back-titration, where the reductant is added in excess, allows indirect quantification of Mn²⁺ by difference, with each mole of Mn²⁺ equivalent to two moles of Fe²⁺ consumed. This approach is advantageous for unstable or slowly reacting reducing analytes, such as , where direct addition may lead to incomplete reaction or decomposition. For instance, in analysis, excess KMnO₄ oxidizes the analyte to , and the residual is back-titrated to avoid endpoint ambiguity in direct methods. Calculations involve determining the equivalents of unreacted KMnO₄ from the back-titration volume and normality of the reductant, using the 1:5 electron transfer ratio for KMnO₄ to Mn²⁺ in acidic medium (MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O). The permanganate consumed by the analyte is the total added minus the unreacted amount; analyte concentration is derived stoichiometrically, e.g., for a 1:2 H₂O₂:KMnO₄ ratio (5H₂O₂ + 2MnO₄⁻ + 6H⁺ → 5O₂ + 2Mn²⁺ + 8H₂O). Representative results show recoveries of 98–102% for ascorbic acid at 0.1–1.0 mM levels using this method. A variant is the reverse titration, where excess reductant (e.g., Fe²⁺ or ) is added to the oxidized form, followed by of surplus reductant with KMnO₄, as seen in the Mn²⁺ example; however, the primary emphasis in indirect permanganometry remains on excess for direct oxidant-analyte compatibility.

Applications

In Inorganic Analysis

Permanganometry plays a key role in the of iron in inorganic samples, particularly in ferrous ammonium sulfate and iron ores. For ferrous ammonium sulfate, the sample is dissolved in dilute to yield Fe²⁺ ions, which are then directly titrated with solution in an acidic medium, where the is indicated by the appearance of a persistent pink color due to excess . In the case of iron ores, the sample is first dissolved in concentrated to convert iron oxides to soluble Fe³⁺, followed by to Fe²⁺ using stannous chloride (SnCl₂); any excess reductant is back-titrated with to ensure accurate quantification of the original iron content. This approach allows for precise determination of iron concentrations ranging from 0.1% to over 60% in ore samples, with relative errors typically below 1%. Beyond iron, permanganometry is applied to other metals through indirect methods involving prior oxidation steps. For manganese(II), the indirect procedure oxidizes Mn²⁺ to using an oxidizing agent like in acidic conditions, producing a colored solution whose absorbance or against a reductant quantifies the original Mn²⁺ concentration. Chromium(III) determination requires oxidation to Cr(VI) using excess in , followed by destruction of surplus with and subsequent quantification of the Cr(VI) via or . For vanadium in alloys, V(IV) or V(V) species are adjusted to a specific , often V(IV), and titrated directly with in acidic medium, enabling accurate analysis in materials like vanadium-aluminum master alloys with contents up to 50%. The technique also quantifies certain inorganic anions by their oxidation to higher valence states. Nitrite (NO₂⁻) is determined by direct titration with permanganate in weakly acidic conditions, where it is oxidized to nitrate (NO₃⁻), providing a straightforward method for concentrations in the millimolar range. Sulfide (S²⁻) undergoes titration in alkaline medium to sulfate (SO₄²⁻), with thermometric detection of the endpoint for enhanced precision in natural water samples containing low sulfide levels. Arsenite (As(III)) is titrated directly to arsenate (As(V)) using permanganate in sulfuric acid, a method historically used for standardizing permanganate solutions and applicable to trace arsenic analysis. Sample preparation is crucial for reliable results in inorganic permanganometry, often involving acid to solubilize analytes while minimizing interferences. Ores and alloys are typically treated with hydrochloric or to achieve complete , ensuring all target species are in reactive ionic form before . Interferences, such as the yellow color of Fe³⁺ obscuring the endpoint in iron analyses, are masked by adding , which forms a colorless with Fe³⁺, thereby sharpening the visual detection and improving accuracy to within 0.5%. Other masking agents, like for aluminum or , may be employed depending on the matrix to prevent side reactions.

In Environmental and Organic Analysis

In environmental analysis, permanganometry plays a key role in evaluating water quality through the permanganate index, which quantifies the oxidizable organic and inorganic matter in samples such as surface water and wastewater. This method, standardized under ISO 8467 and incorporated into EU water quality directives, involves heating a water sample with potassium permanganate (KMnO₄) and sulfuric acid at 96–98°C for 10 minutes to oxidize reducible substances, followed by back-titration of excess permanganate with ammonium iron(II) sulfate or measurement of residual permanganate. The permanganate index provides an estimate of chemical oxygen demand (COD) equivalent, typically expressed in mg/L O₂, and is particularly useful for monitoring contamination in potable water sources where chloride levels are below 300 mg/L, though dilution is required for indices exceeding 10 mg/L. While not ideal for heavily polluted wastewater due to incomplete oxidation of resistant organics, adaptations using KMnO₄ as the oxidant have been applied to estimate COD in industrial effluents, including saline samples, offering a greener alternative to dichromate-based methods with comparable accuracy for moderate organic loads. In soil analysis, permanganometry assesses oxidizability via permanganate-oxidizable carbon (POXC), a labile fraction of soil organic matter that indicates soil health and microbial activity; the procedure oxidizes soil extracts with 0.02 M KMnO₄ at room temperature, measuring color change spectrophotometrically at 550 nm to quantify active carbon in mg/kg. For organic analysis, permanganometry enables direct or indirect quantification of specific compounds in complex matrices. Oxalates in biological samples, such as or tissues, are determined by acidifying the sample and titrating with standardized KMnO₄, where reduces to Mn²⁺ in a 5:2 , allowing detection of elevated levels associated with conditions like ; this classical reaction is reliable for concentrations down to 0.1 mmol/L after . Ascorbic acid () content in fruits and juices is similarly assessed via with KMnO₄ in acidic medium, where ascorbate reduces permanganate stoichiometrically (1:2), providing rapid results for quality control in samples like or strawberries, with recoveries typically 95–105%. in bleaches and disinfectants is quantified by direct permanganometry, involving in dilute where H₂O₂ reduces KMnO₄ (5:2 ratio), suitable for commercial formulations at 3–30% concentrations with high precision (±0.5%). In pharmaceutical analysis, permanganometry supports the oxidative of certain drugs in formulations. Modern variants enhance permanganometry's for trace-level environmental organics, particularly through spectroscopic adaptations. In spectrophotometric permanganometry, residual KMnO₄ after reaction with trace organics (e.g., or pesticides in ) is measured at 525 nm, achieving detection limits of 0.01–0.1 mg/L COD_Mn without , as seen in methods using N,N-diethyl-p-phenylenediamine () for natural waters. These approaches, often automated, improve throughput for monitoring low-concentration pollutants in effluents, correlating well with traditional COD while reducing use.

Advantages and Limitations

Advantages

One of the primary advantages of permanganometry is its self-indicating nature, where the intense color of the permanganate ion (MnO₄⁻) serves as a built-in indicator for detection. During the , the color fades as the oxidant reacts with the , and a single drop of excess solution imparts a distinct hue, allowing for precise visual determination without the need for additional indicators, which minimizes errors associated with indicator selection or interference. Potassium permanganate acts as a strong oxidant with a high standard of +1.51 V in acidic medium, enabling the of weak reducing agents that might not be accessible to milder oxidants. This versatility extends its utility to a broad range of analytes, including iron(II), oxalates, and nitrites, making it suitable for diverse determinations in inorganic and contexts. The method is highly cost-effective, as is an inexpensive, readily available reagent that requires minimal equipment for setup, such as basic glassware and no specialized instrumentation for routine analyses. Its solutions, once standardized, remain stable for 1–2 weeks under proper conditions, further reducing preparation costs and time compared to less stable titrants. Permanganometry offers rapid reaction kinetics in acidic environments, often completing titrations in minutes, combined with high accuracy and precision; for macro-scale analyses, relative errors can be maintained below 0.1–0.5% through careful technique. This reliability stems from the sharp color change and stoichiometric reactions, providing consistent results in both and field settings. The technique's wide applicability spans from advanced research in to educational demonstrations, where its vivid color changes facilitate clear visualization of principles for students, enhancing learning without complex setups.

Limitations and Error Sources

Permanganate solutions exhibit instability, decomposing in the presence of light, heat, or impurities to form and oxygen, which alters the concentration and necessitates frequent to maintain accuracy. This decomposition is catalyzed by factors such as manganese(II) ions or , potentially leading to significant errors if solutions are not prepared fresh or stored properly in amber bottles. Permanganometry is restricted primarily to acidic media for reliable results; in neutral or alkaline conditions, permanganate reduces to brown precipitate, which obscures the color change and complicates detection. Use of is avoided due to interference from chloride ions, which are oxidized to gas, consuming excess permanganate and inflating volumes. Oxidizable organic compounds interfere by reacting with permanganate to produce colloidal , masking the color transition. High concentrations of salts can diminish the intensity of the permanganate purple hue, affecting visual determination. Temperature plays a critical role, with overheating promoting permanganate decomposition and low temperatures slowing kinetics, potentially causing premature endpoints or incomplete s. Optimal temperatures depend on the ; for example, 60–90°C for oxalates to ensure completion, while iron(II) titrations can use . Deviations from analyte-specific recommendations can introduce errors exceeding 0.1% in permanganate consumption. To mitigate these issues, is employed to provide the necessary acidic environment without introducing reducible anions, while masks interfering colors from species like Fe³⁺ by forming colorless complexes, sharpening the endpoint. Blank corrections account for background reactions or impurities, and for trace analyses or complex matrices, instrumental methods such as potentiometric or spectrophotometric detection replace visual endpoints to reduce subjectivity.

References

  1. [1]
  2. [2]
    [PDF] Experiment 8 – Redox Titrations Potassium permanganate, KMnO4 ...
    Experiment 8 uses potassium permanganate, a strong oxidizing agent, in redox titrations. It standardizes permanganate and uses it to find iron(II) ...
  3. [3]
    Permanganate Titrations
    4. Titrate the iron solution in the flask. The pinkish color produced by the first drop of excess KMnO4 signals the end point for the titration.
  4. [4]
    Permanganometric Titration for the Quantification of Purified Bis(2,4 ...
    Mar 30, 2021 · Permanganometry is a type of redox titration in which the strongly colored and oxidizing permanganate anion (MnO4–) is used to quantify the ...
  5. [5]
    Redox Titration - Chemistry LibreTexts
    Aug 15, 2021 · In an acid–base titration or a complexation titration, the titration curve shows how the concentration of H3O+ (as pH) or Mn+ (as pM) changes ...
  6. [6]
    [PDF] vogel-permanganometry.pdf
    The permanganate solution may then be standardised against sodium oxalate at about 80 °C using the same procedure in the standardisation as in the analysis.<|control11|><|separator|>
  7. [7]
    [PDF] HISTORY OF ANALYTICAL CHEMISTRY
    ... Dumas established that hydrogen can be substituted by chlorine in organic compounds, whereas according to the electrochemical theory it would be impossible ...
  8. [8]
    Nitrocellulose redox permanganometry: A simple method for ...
    Potassium permanganate is commonly used for redox titrations ever since the discovery of permanganometry by Margueritte in 1846 [6]. It is a strong oxidant ...
  9. [9]
    [PDF] 2016 - USP-NF
    ... Potassium Hydroxide TS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54. 0.2 M ...
  10. [10]
    [PDF] The Permanganate Index and Permanganate Value
    The Permanganate Index Test which forms the first part of this booklet was developed to meet the requirements of a European Community Directive(').<|control11|><|separator|>
  11. [11]
    P1: Standard Reduction Potentials by Element - Chemistry LibreTexts
    Dec 17, 2021 · Reduction reactions in acidic solution are written using H+ in place of H3O+. You may rewrite a reaction by replacing H+ with H3O+ and ...
  12. [12]
    [Solved] Write the balanced chemical equation that corresponds to the
    The balanced chemical equation for the titration of Fe2+ with MnO4- in acidic medium is as follows: 5Fe2+ + MnO4- + 8H+ → 5Fe3+ + Mn2+ + 4H2O
  13. [13]
    In the reactant of KMnO 4 with an oxalate in acidic medium. MnO 4
    Detailed Solution. Reaction of KMnO₄ with Oxalate in Acidic Medium. Balanced Chemical Equation: 2MnO₄⁻ + 5C₂O₄²⁻ + 16H⁺ → 2Mn²⁺ + 10CO₂ + 8H₂O. Redox Changes ...
  14. [14]
    Potassium Permanganate (KMnO 4 ) is an inorganic ... - BYJU'S
    Reaction with acid: When permanganate reacts with concentrated hydrochloric acid it produces chlorine. In a neutral solution, permanganate is reduced by ...
  15. [15]
    [PDF] Standardization of permanganate solutions with sodium oxalate
    Kolthoff 14 has shown that the amount of peroxide formed when oxalate is partially titrated with permanganate increases with rise in temperature and with ...
  16. [16]
    What role does sulfuric acid play in the titration of oxalic acid and ...
    Oct 12, 2015 · Sulfuric acid is used because it is stable towards oxidation; whereas, for example, hydrochloric acid would be oxidized to chlorine by permanganate.
  17. [17]
    Analytical procedures and methods validation for oxalate content ...
    In the oxalate measurement method, permanganate will be reduced by oxalate, C2O4 2− in acidic conditions. Oxalate reacts very slowly at room temperature so the ...
  18. [18]
    Potassium Permanganate - Ricca Chemical Company
    Titrations with Permanganate must be carried out in strong acid solution. Sulfuric Acid is generally used for this purpose because Nitric Acid and Hydrochloric ...Missing: concentration | Show results with:concentration<|separator|>
  19. [19]
    [PDF] Control of Manganese Dioxide Particles Resulting From In Situ ...
    Aug 1, 2008 · Manganese dioxide (MnO2) particles are products of the reaction of permanganate with organic contaminants and naturally-reduced subsurface ...
  20. [20]
    Preparation and Standardization of 0.02 M Potassium Permanganate
    Sep 25, 2010 · Potassium Permanganate Solution Preparation. Dissolve 3.2 g of potassium permanganate in 1000 ml of water. Heat on a water-bath for 1 hour.
  21. [21]
    The Determination of Iron (II) by Redox Titration
    Iron(II) is determined by titrating with potassium permanganate, first standardizing the permanganate, then using it to titrate an unknown sample to find the % ...
  22. [22]
    How can you prepare a 2M H2SO4 from conc. H2SO4? - ECHEMI
    Take 900 ml of plain water, add your 100ml of concentrated H2SO4. Mix all this together and you now have 2 moles of H2SO4 in 1L of solution.
  23. [23]
    [PDF] 4. Preparation & standardization of Potassium permanganate
    Dissolve 3.2g of potassium permanganate in 1000ml of water, heat on a water bath for 1 hour, allow to stand for 2 days. Filter the solution through glass wool.
  24. [24]
    Potassium Permanganate Storage and Purity - Chemical Forums
    Aug 26, 2014 · Once mixed with water the shelf life is 3 days. Even if kept in the fridge. Definitely much longer. Several days can be enough for the ...
  25. [25]
    Oxidation-Reduction Equations
    The reaction between oxalic acid and potassium permanganate in acidic solution is a classical technique for standardizing solutions of the MnO4- ion. These ...
  26. [26]
    Quantitative Analysis Using Titrations - Highland Community College
    Thus each mole of MnO 4 − added consumes 2.5 mol of oxalic acid. B Because we know the concentration of permanganate (0.0247 M) and the volume of permanganate ...
  27. [27]
    Standardization of permanganate solution for use in potentiometric ...
    Nov 13, 2024 · Sodium oxalate is probably the most important standard substance used in permanganometry. Oxalate is easily oxidized to carbon dioxide ...
  28. [28]
    [PDF] Use of arsenious oxide in the standardization of solutions of ...
    Values obtained in the standardization of 0.1 N potassium permanganate solutions by National Bureau of Standards' standard sample of arsenious oxide.
  29. [29]
    [PDF] Analytical Utility of Potassium Permanganate for the Assay of ...
    The standard potential in acid solution, E, has been calculated to be 1.51 volts, hence the permanganate ion in acid solution is a strong oxidizing agent. ...
  30. [30]
    Permanganate Titration Methods - BrainKart
    Mar 21, 2018 · In the indirect method of permanganate oxidation certain compounds are first converted by means of chemical reactions to an equivalent amount of ...Missing: principle | Show results with:principle
  31. [31]
    Determination of the Mn Content of Steel - Chemistry LibreTexts
    Jun 29, 2020 · A colorimetric method based on the characteristic purple color of the permanganate ion, MnO 4 - , however, yields accurate results.
  32. [32]
    Efficient Estimation of ascorbic acid in vitamin C tablets enabled by ...
    This method entailed the reaction between ascorbic acid and an excess of potassium permanganate. Subsequent reaction of the residual potassium permanganate ...
  33. [33]
    [PDF] Determination of hydrogen peroxide concentration by titration with ...
    This method describes the determination of the concentration of hydrogen peroxide by titration with potassium permanganate. The reaction is carried out in a ...
  34. [34]
    ESTIMATION OF IRON BY POTASSIUM PERMANGANATE
    Feb 6, 2018 · To the solution , in the flask add about half a gram of Na2CO3 10H2O (crystal). This fills the flask with CO2. Quickly insert the iron wire, ...
  35. [35]
    [PDF] Determination of Manganese Concentration in Fertiliser
    This method uses a redox reaction to produce a coloured solution of permanganate from manganese ions. The manganese is oxidised to permanganate by reacting it.
  36. [36]
    [PDF] DETERMINATIONS OF CHROMIUM(III) and CHROMIUM(VI) - TSAR
    The method is based on the oxidation of sym-diphenylcarbazide with. Cr(VI). Chromium (III) in solution is oxidized by permanganate to Cr(VI). Excess ...
  37. [37]
    Determination of Vanadium in Vanadium-Aluminium alloys by ...
    Abstract: A method for the determination of Vanadium in Vanadium-Aluminium master alloys by KMnO4 -Ferrous titration method is presented .
  38. [38]
    The rapid determination of sodium nitrate, sodium nitrite, chromium ...
    (2) Sodium nitrite is titrated directly with potassium permanganate solution in a weak sulfuric acid solution without the effect of sodium chromate. (3) ...
  39. [39]
    Determination of sulfide in natural waters by thermometric titrimetry
    The thermometric titration of sulfide with permanganate in alkaline solution has been investigated as a potential analytical method for the determination of ...
  40. [40]
    ISO 8467:1993 - Determination of permanganate index
    In stockThe method involves heating a sample with permanganate and sulfuric acid, then using oxalate and titration to determine consumed permanganate. It applies to ...Missing: EU | Show results with:EU<|separator|>
  41. [41]
    potassium permanganate as oxidant in the cod test for saline water ...
    Aug 7, 2025 · The objective of this study is to investigate the feasibility of applying potassium permanganate (KMnO4) as the oxidant in the COD test for highly saline water ...
  42. [42]
    Procedure for the Determination of Permanganate Oxidizable Carbon
    Oct 24, 2023 · This procedure describes a technique for the determination of permanganate oxidizable carbon (POXC) in soil samples.Missing: oxidizability | Show results with:oxidizability
  43. [43]
    Rapid Determination of Ascorbic Acid in Vegetable by Potassium ...
    Dec 8, 2011 · Abstract: A new rapid determination method of ascorbic acid content in vegetable by potassium permanganate titrimetry was studied.
  44. [44]
    Hydrogen peroxide | Analytical Methods - Evonik Active Oxygens
    This method describes the determination of the concentration of hydrogen peroxide by titration with potassium permanganate. The reaction is carried out in a ...
  45. [45]
    spectrophotometric analysis of vitamin c in different matrices utilizing ...
    Feb 2, 2018 · The aim of this study was to evaluate a spectrophotometric method utilizing potassium permanganate to quantify vitamin C in different matrices.
  46. [46]
    Sulfadiazine oxidation by permanganate: Kinetics, mechanistic ...
    Oct 1, 2018 · In this study, the reactions of the sulfonamide antibiotics with permanganate in aqueous solution were investigated using SDZ as a model ...Missing: sulfanilamide | Show results with:sulfanilamide
  47. [47]
    Spectrophotometric determination of trace permanganate in water ...
    The DPD method was accurate and sensitive for measuring trace permanganate concentration in natural waters and wastewater. •. The DPD method was effective in ...
  48. [48]
    Rapid spectrophotometric determination of permanganate index ...
    In this study, a novel and rapid spectrophotometric method for accurately measuring permanganate index (CODMn) in water samples was developed using 2 ...Missing: compounds | Show results with:compounds
  49. [49]
    None
    ### Summary of Advantages of Permanganometry from the Document
  50. [50]
    [PDF] SCHOTT Instruments - Clarkson Laboratory & Supply Inc
    permanganometry...) (2). Halogenide titrations (chloride,. +. +. “salt“, bromide ... an accuracy of more than 0.1% can be achieved. The great versatility ...
  51. [51]
    Redox titration: principles & types - PraxiLabs
    Sep 23, 2025 · Permanganometry uses potassium permanganate. Now, we will discuss the types in detail. Permanganate Titrations.Introduction · What are the types of Redox... · Applications of Redox Titration
  52. [52]
    [PDF] Standardization of potassium permanganate solution by sodium ...
    permanganate was employed, this stock being prepared in the same manner as the main solution. About 40 grams of solution were used for each titration. Page ...Missing: permanganometry | Show results with:permanganometry
  53. [53]
    Why HCl should not be used for potassium permanganate titrations?
    Dec 14, 2022 · Permanganate titration cannot be performed with hydrochloric acid as it can be oxidized to produce chlorine gas. As a result, we do not obtain ...
  54. [54]
    Permanganometric titration of iron (II)
    Nov 13, 2024 · To avoid the problem we can add phosphoric acid to the solution. Phosphate complex has higher stability constant and is colorless. Second, ...