Fact-checked by Grok 2 weeks ago

Quantitative computed tomography

Quantitative computed tomography (QCT) is a specialized imaging technique that utilizes computed tomography (CT) scanners to provide precise, volumetric measurements of bone mineral density (BMD) and structural bone properties, distinguishing it from qualitative CT imaging by enabling quantitative analysis of bone health. Introduced in the mid-1970s, QCT typically involves acquiring two-dimensional slices, most commonly in the lumbar spine, to assess trabecular BMD in milligrams per cubic centimeter, though it can also evaluate cortical bone separately and peripheral sites like the radius or tibia using dedicated peripheral QCT (pQCT) devices. This method yields size-independent volumetric BMD, unlike areal measurements from dual-energy X-ray absorptiometry (DXA), and incorporates geometric and structural parameters that contribute to evaluating bone strength and fracture risk. QCT offers several advantages over DXA for assessment, including the ability to isolate trabecular , which has higher metabolic turnover and thus greater to early changes in conditions like . It is not confounded by overlying soft tissues or cortical superposition, providing more accurate detection of low mass, with studies showing higher identification rates—up to 69.6% compared to 34.1% with DXA in certain populations. However, the World Health Organization's T-score criteria for (T-score ≤ -2.5) apply primarily to DXA, requiring adapted thresholds for QCT interpretations. from central QCT ( or ) ranges from 1 to 3 mSv, higher than DXA's 10–15 μSv but comparable to standard spinal radiographs, while pQCT doses are negligible. Clinically, QCT is widely applied in diagnosis, treatment monitoring, and risk prediction, particularly in populations with abnormal glucose or limited DXA access. Opportunistic screening leverages routine scans—such as abdominal or pelvic exams—for asynchronous BMD evaluation without additional or patient time, enhancing early detection in at-risk groups. Advances in multi-detector technology have expanded QCT to three-dimensional volumetric imaging of the proximal , trabecular microstructure analysis, and finite element modeling for biomechanical simulations, supporting research into development, effects, and therapeutic interventions.

Overview

Definition and principles

Quantitative computed tomography (QCT) is a non-invasive technique that employs imaging to quantify volumetric in absolute units of mg/cm³. This approach provides three-dimensional measurements of , distinguishing it from areal density assessments like those from , which yield projected values in g/cm² and are influenced by thickness and overlying . By isolating specific compartments, QCT enables precise evaluation of skeletal health without the confounding effects of body size or anatomy overlap. The foundational principles of QCT are rooted in the physics of X-ray attenuation, where the degree to which X-rays are absorbed or scattered by tissues is measured and expressed in Hounsfield units (HU); in this scale, water is assigned 0 HU, air -1000 HU, and denser materials like bone positive values proportional to their attenuation coefficients. To translate these relative HU measurements into absolute BMD, calibration phantoms—typically containing rods of known hydroxyapatite concentrations—are scanned with the patient, allowing for a linear conversion via established equations such as BMD = a × HU + b, where a and b are phantom-derived coefficients. This calibration process is essential for accurately quantifying the distinct densities of trabecular (low-density, porous) and cortical (high-density, compact) bone, as their differing attenuation properties permit selective analysis within the same scan. Biologically, QCT emphasizes the assessment of trabecular , which constitutes the metabolically active, inner spongy network of vertebrae and long s and undergoes rapid remodeling and early density loss in , enabling sensitive detection of preclinical skeletal fragility. The technique computes BMD by analyzing densities within a user-defined (ROI), as the average of the calibrated densities (derived from HU values reflecting mineral content) within the ROI, providing a true size-independent volumetric metric. This focus on trabecular compartments enhances the method's utility in monitoring changes over time. The term "quantitative computed tomography" originated in the mid-1970s, marking the shift from qualitative CT image interpretation to standardized, numerical analysis of tissue densities for clinical applications.

Measurement techniques

Quantitative computed tomography (QCT) employs standardized scan protocols to ensure precise mapping of bone mineral density (BMD). Single-energy scans are commonly conducted at tube voltages ranging from 80 to 140 kVp, providing sufficient contrast for trabecular bone differentiation while minimizing beam hardening artifacts. Dual-energy protocols, often using paired voltages such as 100 kVp and 140 kVp, enable material decomposition to isolate bone from marrow fat and soft tissues, enhancing quantification accuracy in heterogeneous regions. Slice thicknesses of 1-3 mm are standard to capture fine structural details without excessive partial volume effects, paired with voxel resolutions of 0.5-1 mm in-plane to support volumetric reconstructions. Region of interest (ROI) selection in QCT focuses on volumetric analysis to target specific compartments. Contouring algorithms automatically detect and outline trabecular regions within vertebral bodies or femoral necks by identifying edges based on gradients and anatomical landmarks, reducing variability and enabling three-dimensional BMD integration. These semi-automated or fully automated methods process multi-slice data to generate precise, reproducible ROIs that exclude cortical and extraneous tissues. Proprietary software tools, such as , streamline BMD computation through -based integrated with the . The system scans a containing rods of known densities (typically aqueous K₂HPO₄ equivalents) alongside the patient, generating a linear to convert Hounsfield units—measures of relative to —to absolute BMD values. The follows the formula \text{BMD} = a \times (\text{HU} - b) where a and b are empirically derived constants from the phantom's HU-density relationship, ensuring to standardized units like mg/cm³. Hounsfield units provide the foundational scale for this conversion, calibrated against the to yield quantitative density estimates. protocols are essential to maintain measurement reliability. Pre-scan, the is positioned adjacent to or beneath the patient to capture scanner-specific characteristics during the same session. Post-scan verification involves analyzing data to confirm , with deviations typically controlled to within 1-2% error through adjustments for drift or inconsistencies, thereby upholding longitudinal comparability across scans.

History

Early development

Quantitative computed tomography (QCT) emerged in the mid-1970s as an extension of (CT) technology, initially developed at the (UCSF) by Harry K. Genant and colleagues to enable precise measurement of bone mineral density (BMD). Building on the rapid adoption of CT scanners following their invention in the early 1970s, researchers adapted the technique for quantitative assessment of bone, focusing on trabecular bone's metabolic sensitivity to conditions like . The foundational work began with dual-energy CT approaches to separate bone mineral from soft tissue and fat influences, as detailed in Genant and Boyd's 1977 study, which demonstrated the feasibility of measuring cancellous, cortical, or integral bone mineral content. Christopher E. Cann contributed significantly to refining these methods at UCSF, leading to practical implementations for by the late 1970s. Initial applications of QCT utilized single-slice scans to quantify trabecular BMD in the lumbar spine, targeting early detection of bone loss in studies. These early efforts highlighted QCT's ability to isolate metabolically active trabecular , offering greater sensitivity to age- and disease-related changes compared to conventional , which primarily visualized structural alterations rather than density. For instance, foundational research at UCSF applied QCT to postmenopausal women, revealing rapid trabecular bone loss that was undetectable by radiographic means alone. Key publications in the solidified QCT's role as a reliable standard for BMD assessment, with validation studies confirming its accuracy against direct measures like ash weight in cadaveric vertebrae. Cann and Genant's 1980 work on precise vertebral mineral content measurement using with external calibration established reproducibility of 1.5% for serial scans. Additional studies, including those validating spinal QCT against chemical analysis of excised vertebrae, reported correlations such as r = 0.86 between QCT values and ash density, underscoring the technique's precision for both trabecular and cortical compartments. These efforts, often involving UCSF prototypes like the modified 7800 scanner, positioned QCT as a superior tool for longitudinal monitoring. Technological precursors to QCT involved transitioning from qualitative CT diagnostics—used for anatomical visualization since the 1970s—to through the integration of phantoms. Introduced around 1978, these phantoms, typically containing known concentrations of or dipotassium hydrogen phosphate solutions, enabled conversion of Hounsfield units to absolute BMD values (mg/cm³), correcting for scanner variations and beam hardening effects. Early phantoms, such as those developed by the UCSF group, facilitated accurate single-energy QCT measurements of spinal trabecular , marking a pivotal shift toward standardized, volumetric quantification.

Advancements in three-dimensional imaging

The introduction of helical (spiral) computed tomography scanners in the early 1990s marked a pivotal advancement in quantitative computed tomography (QCT), enabling continuous volumetric data acquisition during a single breath-hold and facilitating true three-dimensional (3D) reconstructions of bone structures. This shift from sequential single-slice imaging to helical scanning improved spatial resolution and minimized motion artifacts, allowing for more accurate delineation of complex bone geometries such as the proximal femur. In hip assessments, helical CT substantially reduced partial volume errors by enabling thinner slice collimation and multi-planar reformatting, which enhanced the precision of bone mineral density (BMD) measurements in trabecular and cortical compartments. Building on these foundations, the 2000s saw the of volumetric region-of-interest (ROI) analysis software tailored for QCT, which permitted comprehensive segmentation of volumes and integration with finite element (FE) modeling techniques. These innovations extended QCT beyond traditional BMD quantification to predict mechanical strength under load-bearing conditions, incorporating patient-specific , distribution, and properties derived from Hounsfield unit calibration. For instance, FE models generated from QCT data demonstrated superior correlation with vertebral (R² > 0.85) compared to BMD alone, offering a more holistic of in osteoporotic patients. More recent developments through 2025 have integrated (AI) for automated segmentation in 3D QCT workflows, with studies from 2024 reporting high similarity coefficients (e.g., >90%) for proximal and vertebral outlining using deep learning-based QCT, thereby reducing operator variability and analysis time. Concurrently, low-dose protocols implemented since 2015, leveraging algorithms and tube current modulation (e.g., 80-120 kVp at 120 ), have lowered effective doses to under 200 μSv while maintaining BMD within 2%. Recent advancements include harmonized low-dose protocols for multi-center QCT and studies as of 2024-2025. These advancements have collectively enhanced the reproducibility of 3D QCT, with 2005 studies showing short-term errors of approximately 1.5% for spinal trabecular BMD versus 3% for two-dimensional methods.

Clinical Applications

Central QCT for spine and hip

Central quantitative computed tomography (QCT) primarily assesses bone mineral density (BMD) in the , with the lumbar spine and proximal femur serving as key sites for diagnosing and predicting fracture risk. For the lumbar spine, the protocol typically involves single-slice or volumetric scans targeting the L1-L3 vertebrae to measure trabecular BMD, which is particularly sensitive to early bone loss due to its metabolic activity. A calibration phantom is used during or asynchronously with the scan to ensure accurate volumetric measurements in mg/cm³. Normal trabecular BMD in young adults exceeds 120 mg/cm³, while values between 80 and 120 mg/cm³ indicate , and those below 80 mg/cm³ signify , aligning with adapted (WHO) criteria via T-scores. Longitudinal studies from the onward have demonstrated that low trabecular BMD at these levels predicts vertebral fractures in postmenopausal women, with hazard ratios increasing significantly below 80 mg/cm³. The protocol employs volumetric QCT to analyze the proximal , focusing on the and regions, where integral BMD (including both trabecular and cortical compartments) is calculated to account for site-specific geometry and load-bearing properties. Dual-energy scanning is often applied to correct for fat content, which can artifactually affect apparent BMD in uncorrected single-energy measurements, ensuring more precise density estimates. This approach generates DXA-equivalent T-scores for the total and , facilitating direct comparison to WHO diagnostic thresholds (T-score ≤ -2.5 for ). Clinical relevance is underscored by evidence that total trabecular BMD measured by QCT predicts fractures in postmenopausal women and older men, with prospective cohorts showing improved over areal methods alone. Patient positioning for central QCT scans is , with the patient centered in the and arms elevated above the head or crossed over the chest to minimize beam-hardening artifacts from and metal objects. This setup, combined with views for precise alignment, ensures optimal image quality for both and acquisitions, typically completed in 10-20 seconds per site using low-dose helical protocols. Such standardization enhances reproducibility, with precision errors under 2% for repeated measurements in monitoring treatment responses.

Peripheral QCT for extremities

Peripheral quantitative computed tomography (pQCT) is specialized for imaging peripheral skeletal sites, particularly the such as the () and lower leg (), enabling detailed assessment of geometry and density without the need for central body scanning. This approach focuses on and non-weight-bearing s, providing insights into cortical and trabecular compartments that are critical for evaluating bone strength and adaptation in various conditions, including pediatric growth monitoring. Portable pQCT scanners, such as the Stratec XCT series (e.g., XCT 2000L and XCT 3000), are commonly used for these measurements, featuring compact designs suitable for clinical or settings. These devices acquire cross-sectional images with slice thicknesses of 1-2 mm, typically at standardized sites like the distal (4% of length from the ulnar styloid) or mid-tibia (50% of length), allowing precise volumetric analysis of peripheral structures. The XCT 3000, for instance, employs an at 60 kV and 0.3 mA with a focal spot size of 250 × 250 μm, ensuring high-resolution imaging of limb extremities. pQCT enables separate quantification of key parameters, including cortical thickness (CoTh), periosteal circumference, and muscle cross-sectional area (), which provide comprehensive data on and interactions. strength is estimated using the polar (I_p), calculated as: I_p = \int r^2 \, dA where r is the radial distance from the and dA is the differential area element, offering a geometric indicator of torsional . These metrics allow for the differentiation of cortical and trabecular , facilitating the study of muscle-bone unit dynamics in extremities. In clinical practice, pQCT is particularly valuable for detecting secondary osteoporosis in patients with (CKD), where it reveals deficits in cortical geometry and trabecular microstructure that contribute to fracture risk. Studies from the using high-resolution pQCT (HR-pQCT) variants have demonstrated its utility in assessing and disorder in CKD, showing enhanced detection of cortical thinning compared to traditional methods. This makes pQCT a targeted tool for health in CKD populations, especially at extremity sites prone to fragility. The scan procedure is well-suited for outpatient settings, with a typical duration of approximately 5 minutes per site, minimizing discomfort and while focusing on accessible, bones like the . This feasibility enhances its adoption for longitudinal assessments in .

Emerging uses beyond

Quantitative computed tomography (QCT) has expanded beyond skeletal applications to quantify distribution, particularly in abdominal imaging where visceral (VAT) volume is segmented using Hounsfield unit (HU) thresholds ranging from -190 to -30 HU to distinguish it from subcutaneous (SAT). This approach enables precise volumetric measurements at the L4-L5 vertebral level, revealing associations between elevated VAT (>100 cm²) and increased risk of , including and . Studies demonstrate that QCT-derived VAT quantification outperforms traditional metrics like waist circumference in predicting cardiometabolic complications, with VAT/SAT ratios serving as a robust indicator of obesity-related risks. In pulmonary medicine, QCT facilitates the quantitative assessment of by measuring low-attenuation (LAV) percentages below -950 HU, which correlates strongly with airflow obstruction severity in (COPD). This metric, expressed as the proportion of voxels with densities under this threshold, aids in phenotyping COPD subtypes, such as centrilobular predominant in smokers. Recent advancements incorporate ()-enhanced protocols from 2023 onward, which automate LAV segmentation and improve diagnostic accuracy for COPD progression monitoring by reducing inter-observer variability by up to 30% compared to methods. These tools also integrate three-dimensional QCT reconstructions to evaluate airway wall thickness and , enhancing personalized treatment strategies like responsiveness assessment. Beyond these, QCT quantifies liver fat fraction in non-alcoholic fatty liver disease (NAFLD) by analyzing mean hepatic attenuation values, where HU below 40 indicates with high (85-90%) for moderate-to-severe cases confirmed histologically. This non-invasive method leverages unenhanced scans to track fat accumulation, offering advantages over in obese patients by providing volumetric data that correlates with staging. Similarly, QCT-based aortic calcification scoring measures calcium volume in the thoracic or using thresholds above 130 HU, predicting cardiovascular events with hazard ratios up to 2.5 independent of traditional factors like age and . Automated scoring systems enhance reproducibility, supporting stratification in asymptomatic populations for preventive interventions. Emerging research trends from 2024-2025 highlight QCT integration with (PET) for , where hybrid PET/QCT protocols improve tumor density mapping by fusing metabolic and structural data to delineate heterogeneous tumor microenvironments. This multimodal approach enhances lesion segmentation accuracy in cancers like and , enabling better response assessment to with reported improvements in over standalone PET. Such advancements underscore QCT's role in precision , facilitating targeted therapies based on quantitative .

Technical Aspects

Image acquisition and analysis

Quantitative computed tomography (QCT) image acquisition involves optimized parameters tailored to the anatomical site, with central QCT for the employing higher energy settings such as 120 kVp and 100 to penetrate larger body regions effectively. In contrast, peripheral QCT (pQCT) utilizes lower settings, typically around 60 kVp and reduced (e.g., 2-15 ), to achieve sufficient image quality at while minimizing . Scan modes differ based on the need to reduce motion artifacts: helical acquisition is preferred for volumetric coverage in central QCT of the or , allowing continuous scanning with adjustments, whereas sequential mode is often used for single-slice pQCT at sites like the or to ensure precise positioning. The field of view (FOV) and resolution parameters further distinguish central and peripheral approaches. Central QCT requires a large FOV of approximately 50 cm to encompass the , avoiding the use of agents that could interfere with density measurements. pQCT, however, employs a smaller FOV of about 10 cm, enabling high in-plane down to 0.3 mm isotropic voxels for detailed assessment of cortical and trabecular compartments in . Post-acquisition analysis follows a structured pipeline to derive bone mineral density (BMD) and geometric parameters. Semiautomated algorithms identify bone contours by thresholding Hounsfield units and refining boundaries through user-guided adjustments, ensuring accurate segmentation of trabecular and cortical regions. Fat marrow correction algorithms are applied to account for within trabecular spaces, which can attenuate X-rays and bias BMD estimates; these typically involve dual-energy techniques or empirical models to adjust for marrow fat fraction. For three-dimensional visualization and finite element modeling, the marching cubes algorithm reconstructs surface meshes from volumetric data, generating polygonal representations of bone geometry with sub-millimeter precision. Common error sources in QCT imaging include beam hardening, caused by polychromatic spectra leading to cupping artifacts, and partial volume effects at bone-soft tissue interfaces. Beam hardening is mitigated through dedicated correction filters and linearization algorithms integrated into reconstruction software. Partial volume effects are reduced by employing sub-millimeter sizes and thin-slice acquisitions (e.g., 1-3 mm), which enhance edge definition and minimize averaging across heterogeneous tissues.

Radiation dose and safety

Quantitative computed tomography (QCT) involves exposure, with effective doses for central QCT scans of the or typically ranging from 1 to 3 mSv, depending on protocol and scanner settings. This is substantially higher than (DXA), which delivers approximately 0.01 mSv for comparable regions. Effective dose is derived from the dose-length product (DLP), calculated as the volume CT dose index (CTDI_vol) multiplied by scan length, then converted using region-specific factors to estimate whole-body equivalent risk. To mitigate , low-dose QCT protocols employ reduced tube current (e.g., 50-120 ) and lower tube voltage (80-120 kVp), achieving doses below 0.2 mSv while maintaining density (BMD) accuracy for assessment. These strategies can reduce exposure by up to 85-92% compared to standard protocols without compromising diagnostic precision, as validated in clinical studies. The International Society for Clinical (ISCD) recommends preferring DXA when available to minimize radiation but endorses optimized QCT protocols for cases requiring volumetric analysis. Safety protocols in QCT adhere to the ALARA (As Low As Reasonably Achievable) principle, emphasizing dose optimization through protocol selection and limiting scan coverage to essential regions. Although routine gonadal shielding is no longer recommended due to potential interference with and scatter effects, targeted shielding may be considered in select cases to protect radiosensitive organs. For pediatric and pregnant patients, QCT is contraindicated unless the clinical benefit outweighs risks, with alternative non-ionizing modalities prioritized and strict risk-benefit evaluations required under ALARA guidelines. Long-term studies, including 2025 projections and meta-analyses of diagnostic exposures, indicate no directly observed significant increase in cancer incidence from low-dose QCT levels (under 3 mSv), though theoretical lifetime attributable risks remain a consideration for repeated scans. These findings underscore the importance of judicious use, with cumulative exposures monitored to stay below established safety thresholds.

Advantages and Limitations

Key advantages

Quantitative computed tomography (QCT) offers superior reproducibility compared to other measurement techniques, with short-term errors often below 1.5% when using advanced methods such as automatic phantom-less . This high , demonstrated by coefficients of variation as low as 0.89% in clinical validations, enables reliable longitudinal of (BMD) changes, including responses to treatments like bisphosphonates, where small annual variations (typically 1-3%) can be accurately detected without significant operator variability. A key strength of QCT lies in its volumetric accuracy, providing true three-dimensional BMD measurements in mg/cm³ that isolate specific bone compartments, unlike the two-dimensional areal projections (g/cm²) from dual-energy X-ray absorptiometry (DXA). This approach avoids artifacts from bone size, degenerative changes, or overlying tissues, leading to more precise assessments of metabolic bone status. Studies show QCT enhances fracture prediction; for instance, it correctly identifies 81% of patients at risk for incident vertebral fractures compared to 44% with DXA, with an area under the curve (AUC) of 0.76 versus non-significant performance for DXA alone. QCT's dual-purpose capability allows opportunistic BMD evaluation from routine scans without incurring additional , integrating health screening into standard protocols such as abdominal in the . By analyzing vertebral in Hounsfield units from existing non-contrast or contrast-enhanced scans, thresholds like 169 HU achieve 90% for detection, facilitating early intervention in high-risk populations encountered in settings. The technique's specificity for trabecular bone, which turns over more rapidly than cortical bone, enables earlier detection of density changes—often before significant cortical involvement—providing a window for preventive measures up to several years ahead of DXA findings. This metabolic sensitivity is particularly valuable in postmenopausal women, where trabecular loss predominates initially, supporting more targeted risk stratification.

Limitations and contraindications

Quantitative computed tomography (QCT) faces significant accessibility barriers due to its higher cost compared to alternative modalities like (DXA), with reimbursement around $110 per scan as of 2022, though out-of-pocket costs can vary from $100 to $300 depending on location and . Additionally, QCT requires specialized scanners equipped with dedicated software for volumetric density (BMD) analysis, such as QCT PRO systems, which are not universally available and thus restrict its routine use in environments. These factors contribute to lower adoption rates compared to more accessible screening tools. Contraindications for QCT include absolute and relative categories that may exclude certain patients or necessitate alternatives. Absolute contraindications encompass or suspected , owing to the exposure, with DXA recommended as a safer option in such cases. Relative contraindications include recent administration of contrast agents like or iodine, which can interfere with image quality. Technical limitations of QCT arise from its sensitivity to patient-related factors that degrade image quality and precision. Patient motion during acquisition can introduce blurring and artifacts, potentially increasing BMD errors, with studies indicating precision errors up to 4.8% in peripheral QCT under suboptimal conditions. In obese patients, beam hardening artifacts from increased further challenge accurate BMD quantification, although QCT systems incorporate corrections that mitigate but do not fully eliminate these effects. Metal implants in the scan region can produce artifacts that compromise BMD accuracy, prompting consideration of peripheral QCT or DXA as alternatives. QCT also involves higher doses than DXA, typically 0.06–2.9 mSv, raising safety considerations in vulnerable populations. Evidence gaps persist regarding QCT's application across diverse populations, leading to underutilization and challenges in . Recent studies highlight ethnic variations in BMD, with differences of 13–40% across groups depending on site and sex, underscoring the need for population-specific reference databases to avoid misdiagnosis. For instance, lower BMD cutpoints (45–50 mg/cm³) have been proposed for East Asian individuals compared to norms, yet widespread adoption of these adjustments remains limited. This lack of comprehensive ethnic contributes to disparities in detection and management.

Comparison to Other Modalities

Versus dual-energy X-ray absorptiometry (DXA)

Quantitative computed tomography (QCT) and (DXA) differ fundamentally in methodology, with QCT providing three-dimensional volumetric measurements of bone mineral density (BMD) in units of g/cm³, allowing separate of trabecular and cortical compartments, while DXA yields two-dimensional areal BMD in g/cm² that integrates both bone types along the path. This volumetric approach in QCT enables more precise isolation of metabolically active trabecular , which is particularly sensitive to early osteoporotic changes, whereas DXA's projectional imaging can be confounded by overlapping structures such as vascular calcifications or degenerative changes. In obese patients, QCT avoids the overlap and errors that lead to BMD overestimation in DXA, where T-scores can be artificially elevated by 1-2 units due to increased adiposity affecting . Regarding accuracy and precision, QCT demonstrates superior performance for trabecular bone evaluation, with short-term coefficients of variation (CV) typically ranging from 1% to 1.5% for lumbar spine trabecular volumetric BMD, compared to DXA's 1% to 2% CV for total spine areal BMD, which is less specific to trabecular changes due to inclusion of cortical bone and susceptibility to artifacts. QCT's ability to exclude extraneous tissues enhances its sensitivity for detecting early bone loss, particularly in the spine, where trabecular bone turnover is highest, although DXA remains faster and more cost-effective for routine screening. Long-term precision for QCT trabecular measurements remains robust at around 1-2%, outperforming DXA in scenarios involving body habitus variations or spinal deformities. In clinical practice, DXA is recommended as the initial diagnostic tool for per the 2023 International Society for Clinical Densitometry (ISCD) official positions, aligning with National Foundation guidelines for screening in postmenopausal women and older men using T-scores at the , total , or . QCT is preferred for research applications, treatment monitoring of trabecular-specific responses (e.g., to antiresorptive therapies), and cases where DXA is inconclusive, such as in obese individuals or those with , due to its artifact resistance. approaches, combining DXA for areal assessment with QCT for volumetric confirmation, are employed in ambiguous cases to refine fracture risk stratification. Meta-analyses through highlight QCT's enhanced predictive value for , with trabecular volumetric BMD yielding area under the () values of approximately 0.85 in prospective cohorts, surpassing DXA's 0.78 for areal BMD in identifying high-risk patients, particularly by detecting more cases ( 4.91). These findings underscore QCT's niche in prognostic studies, where its sensitivity for trabecular deficits correlates with incidence ( per standard deviation decrease ≈1.4 for trabecular vBMD).

Versus other imaging techniques

Quantitative computed tomography (QCT) differs from quantitative ultrasound () in its approach to assessment, offering direct volumetric measurements of (BMD) in absolute units (g/cm³) that distinguish between cortical and trabecular compartments, whereas provides indirect estimates via speed-of-sound and broadband ultrasound attenuation metrics, typically at peripheral sites such as the . This direct quantification in QCT enhances accuracy for cortical evaluation and central skeletal sites like the and , enabling precise risk prediction through parameters like the Strength-Strain Index. In contrast, is advantageous for its lack of , portability, and suitability as a non-invasive screening tool for , though it shows lower and for trabecular changes compared to QCT. Relative to magnetic resonance imaging (MRI), QCT demonstrates strengths in calcification detection and volumetric BMD precision due to its use of X-rays, with 2023 studies reporting moderate negative correlations (r = -0.47) between MRI-based vertebral bone quality (VBQ) scores and QCT-derived BMD, indicating reliable alignment for screening. However, MRI surpasses QCT in visualizing marrow and inflammatory processes within , providing superior contrast without , which is particularly valuable for assessing conditions like osteoporotic fractures with associated . These complementary capabilities highlight QCT's role in quantitative density analysis versus MRI's qualitative insights into . When compared to standard radiography, QCT provides quantitative BMD data and morphometric analysis for enhanced fracture risk stratification, moving beyond 's qualitative depiction of bone alignment and density variations that often lead to interpretive subjectivity. Standard radiographs exhibit false-negative rates of 30-36% for vertebral fractures due to overlapping structures and degenerative artifacts, whereas QCT's three-dimensional imaging reduces such diagnostic errors by clarifying true osteoporotic deformities from mimics like . Emerging hybrid approaches fuse QCT with MRI to achieve comprehensive evaluation, integrating metrics from QCT with MRI's depiction of and changes, as outlined in 2025 protocols for opportunistic screening in degenerative patients, including AI-enhanced models for improved risk prediction. These fusions, often leveraging VBQ scores correlated to QCT BMD, enable radiation-minimized workflows for high-risk populations, improving overall diagnostic yield without solely relying on one modality.

Reporting and Standardization

Interpretation guidelines

Interpretation of bone mineral density (BMD) results from quantitative computed tomography (QCT) relies on standardized reference databases to calculate T-scores and Z-scores, enabling and . T-scores at the and total hip from QCT are equivalent to (DXA) T-scores, which use the and Nutrition Examination Survey III (NHANES III) database as reference, derived from white females aged 20-29 years; this facilitates diagnosis at these sites, defined as a T-score ≤ -2.5 in postmenopausal women or men aged ≥50 years. For lumbar spine QCT, manufacturer-specific reference databases are applied due to variations in volumetric measurements, with typically defined as trabecular BMD ≤80 mg/cm³, 80-120 mg/cm³, and normal >120 mg/cm³. Z-scores, which compare an individual's BMD to age-, sex-, and ethnicity-matched peers using device-specific or appropriate reference data, are used to identify unexpectedly low BMD (Z-score ≤ -2.0) that may suggest secondary causes of rather than age-related bone loss. Fracture risk assessment incorporates QCT-derived BMD into the Fracture Risk Assessment (FRAX) tool, which estimates 10-year probability of major osteoporotic or by combining BMD with clinical risk factors such as age, prior fracture, and use. QCT-derived areal BMD can be input into FRAX after conversion to DXA-equivalent T-scores, enhancing risk stratification; studies show this improves prediction accuracy. Artifact handling is critical to ensure reliable QCT results, with guidelines recommending exclusion of individual vertebrae affected by local structural changes, degenerative disease, or artifacts; use all remaining evaluable vertebrae to maintain diagnostic validity, as per the International Society for Clinical Densitometry (ISCD) 2023 position statement. If insufficient evaluable regions remain, alternative skeletal sites like the hip should be prioritized. For serial monitoring of BMD changes due to , progression, or aging, a minimum interval of 1 year is recommended between QCT scans to detect clinically meaningful alterations, with follow-up testing individualized based on baseline risk and therapy response. The least significant change (LSC) threshold, calculated as 2.77 times the precision error at the facility (typically 3-5% for lumbar spine trabecular BMD), determines whether observed differences exceed measurement variability and indicate true biological change at 95% confidence.

Quality control and reproducibility

Quality control in quantitative computed tomography (QCT) for bone mineral density (BMD) assessment is essential to ensure measurement accuracy, stability, and consistency across scans and facilities. A key component involves phantom-based protocols, where the European Spine Phantom (ESP)—a semi-anthropomorphic tool with inserts of varying bone mineral densities—is scanned daily or regularly to monitor system performance, assess linearity, and facilitate cross-calibration between scanners. This approach helps minimize inter-site variability by verifying calibration and detecting drifts in equipment, thereby supporting reliable multi-center studies and clinical comparisons. Reproducibility in QCT is influenced by several factors, including operator expertise and technological aids. Standardized operator training programs are critical to achieving high precision, with well-trained technicians typically attaining intra-observer coefficients of variation (CV) below 1% for BMD measurements, as demonstrated in automated and manual segmentation tasks. Recent advancements, such as 2024 deep learning-based automated segmentation frameworks using convolutional neural networks, have further enhanced reproducibility by reducing variability in volumetric BMD (vBMD) assessments; for instance, root mean square CV values as low as 1.3% have been reported for repeated reconstructions on the same scanner, minimizing operator-dependent errors. Standardization efforts are led by organizations like the International Osteoporosis Foundation (IOF) and the International Society for Clinical (ISCD), which provide harmonized protocols for QCT acquisition and analysis to promote . The ISCD's official positions outline specific guidelines for QCT, including scan regions (e.g., L1-L2 for QCT) and methods, with asynchronous calibration permitted if scanner stability is confirmed via phantoms. Recent studies (as of 2025) validate low-dose QCT protocols, which maintain diagnostic accuracy while reducing radiation exposure, showing precision comparable to standard QCT. For longitudinal tracking of BMD changes in patients, precision equations are employed to distinguish true biological shifts from measurement noise. The least significant change (LSC) is calculated as LSC = 2.77 × CV (at 95% confidence), where CV is the site's error; this threshold ensures that observed changes exceeding the LSC reflect clinically meaningful alterations rather than technical variability. ISCD guidelines recommend establishing site-specific CV through duplicate scans of at least 30 patients to apply this equation effectively in monitoring progression or treatment response.

References

  1. [1]
    Quantitative computed tomography - PubMed
    The technique is most commonly applied to 2D slices in the lumbar spine to measure trabecular bone mineral density (BMD; mg/cm(3)).
  2. [2]
    Quantitative computed tomography and opportunistic bone density ...
    A potential opportunity exists for concurrent BMD screening by QCT without the need for any additional imaging, radiation exposure, or patient time.Missing: applications | Show results with:applications<|control11|><|separator|>
  3. [3]
    The study of bone mineral density measured by quantitative ...
    Jul 7, 2022 · Quantitative computed tomography (QCT) also plays a significant role in the prediction, diagnosis, treatment and prevention of osteoporosis and ...
  4. [4]
    Quantitative Computed Tomography - an overview
    Quantitative computed tomography (QCT) is defined as a noninvasive, three-dimensional technique for measuring bone density, providing volumetric density ...
  5. [5]
    acr–spr–ssr practice parameter for the performance of quantitative ...
    QCT is used primarily in the diagnosis and management of osteoporosis and other disease states that may be characterized by abnormal BMD, as well as to monitor ...
  6. [6]
    CT and MR for bone mineral density and trabecular bone score ...
    Oct 3, 2023 · Most importantly, QCT allows true volumetric measurements of the lumbar spine independent of body size that discriminates trabecular and ...
  7. [7]
    Quantitative Computed Tomography (QCT) derived Bone Mineral ...
    Dec 9, 2016 · The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue ...
  8. [8]
    Quantitative Computed Tomography (QCT) - Radiology | UCSF
    Pioneered at UCSF, quantitative computed tomography (QCT) is a test to measure bone mineral density (BMD). It is performed using a computed tomography (CT) ...Missing: invention Genant 1976
  9. [9]
    How CT happened: the early development of medical computed ...
    The first prototype was installed at the University of California San Francisco (UCSF) in 1976. A modified version (CT/X) was installed later at UCSF.Missing: Quantitative Genant
  10. [10]
    Quantitative bone mineral analysis using dual energy ... - PubMed
    This preliminary evaluation indicates that CT scanning permits measurement of cancellous, cortical or integral bone.
  11. [11]
    About Us, QCT Information And Solutions, Mindways Software INC
    Incorporated in 1997, Mindways' can trace its origins to the groundbreaking work at UCSF in the late 1970s leading to the development of the Cann & Genant QCT ...
  12. [12]
    Spinal Mineral Loss in Oophorectomized Women - JAMA Network
    Computed tomography (CT) provides precise anatomic localization coupled with quantitative x-ray attenuation information that can be used to determine bone.
  13. [13]
    Precise measurement of vertebral mineral content using ... - PubMed
    A precise method of measuring vertebral mineral content by computed tomography has been developed. Calibration phantoms scanned with patients are used.Missing: quantitative 1976 paper
  14. [14]
    Computed tomography as a method of estimating bone mineral ...
    Overall correlations of mean quantitative CT (QCT) density with ash density (r = 0.82) and percent mineralization (r = 0.93) were strong.
  15. [15]
    Low-dose CT scanning for quantitative spinal mineral analysis.
    Sep 1, 1981 · Specimens were scanned at 80 kVp with exposures ranging from 23 to 380 mAs using the UCSF/GE research scanner, a modified GE CT/T 7800.
  16. [16]
    Quantitative Computed Tomography (QCT) - SpringerLink
    Cann CE, Genant HK, Kolb FO, Ettinger B (1985) Quantitative computed tomography for prediction of vertebral fracture risk. Metab Bone Dis Rel Res 6: 1–7. CAS ...
  17. [17]
    Milestones in CT: Past, Present, and Future - PMC
    This article describes key historical milestones in CT technology from the earliest days of CT to the present, with a look toward the future of this essential ...
  18. [18]
    Milestones in CT: Past, Present, and Future - RSNA Journals
    Oct 17, 2023 · In 1971, the first patient CT examination by Ambrose and Hounsfield paved the way for not only volumetric imaging of the brain but of the entire ...
  19. [19]
    Reduced partial volume artifacts using spiral computed tomography ...
    Partial volume artifacts could be reduced by narrowing the collimation and summing thin slices. However, in axial scans, the acquisition and reconstruction time ...Missing: hip error percentage
  20. [20]
    New Imaging Modalities in Bone | Current Rheumatology Reports
    Mar 3, 2011 · The digital era has witnessed an exponential growth in bone imaging as new modalities and analytic techniques improve the potential for ...Bone Mineral Density... · Bone Quality Assessment · Multidetector Ct And...<|control11|><|separator|>
  21. [21]
    Finite element analysis for prediction of bone strength - PMC - NIH
    Aug 7, 2013 · This study aims to review the predictability of human bone strength at the three major osteoporotic fracture sites quantified in recently completed in vitro ...Missing: ROI | Show results with:ROI
  22. [22]
    QCT-based finite element models predict human vertebral ... - PubMed
    The QCT-based hFE method provides a quantitative and significantly improved prediction of vertebral strength in vitro when compared to simulated DXA.Missing: volumetric ROI 2000s<|control11|><|separator|>
  23. [23]
    A comparative study of bone density in elderly people measured ...
    Our data suggest that AI-driven BMD quantification demonstrates non-inferior diagnostic accuracy to QCT while overcoming DXA's accessibility limitations.Missing: resolution | Show results with:resolution
  24. [24]
    An anatomic coordinate system of the femoral neck for highly ...
    ... reproducible BMD measurements using 3D QCT ... Subsequently precision errors are higher at the femur compared to the spine (approximately 3% versus 1.5%) [6].
  25. [25]
    Official Adult Positions - ISCD
    Total femur trabecular BMD measured by QCT predicts hip fractures as well as hip BMD measured by DXA in postmenopausal women and older men. pQCT of the forearm ...
  26. [26]
    None
    ### Summary of QCT Protocols and Details
  27. [27]
    Spinal bone mineral density measured with quantitative CT
    This study documents the relationship between different vertebral bone compartments with quantitative computed tomography (CT). Four distinct patient groups ...
  28. [28]
    Accuracy and the influence of marrow fat on quantitative ... - PubMed
    Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro. Osteoporos Int ...Missing: hip volumetric trochanter
  29. [29]
    Technical aspects of CT imaging of the spine
    Oct 21, 2010 · The patient position of choice for CT imaging of the spine is supine, i.e. the patient is lying on his/her back. This ensures minimal ...
  30. [30]
    Peripheral quantitative computed tomography (pQCT) to assess ...
    Peripheral quantitative computed tomography (pQCT) provides volumetric measures of BMD and geometry in both cortical and trabecular bone.
  31. [31]
    Peripheral quantitative computed tomography (pQCT) for the ... - NIH
    Sep 26, 2016 · Peripheral quantitative computed tomography provides an automatical scan analysis of trabecular and cortical bone compartments, calculating not only their bone ...
  32. [32]
    XCT 2000L - pQCT
    Home | Stratec pQCT muscle and bone density & geometry | XCT 2000L. XCT 2000L ... Dimensions total (l/w/h). 1280 x 550 x 620 mm. Weight total. 70 kg. Number ...
  33. [33]
    A reference database for the Stratec XCT-2000 peripheral ... - PubMed
    We have produced paediatric reference data for forearm sites using the Stratec XCT-2000 peripheral quantitative computed tomography scanner.Missing: specifications | Show results with:specifications
  34. [34]
    Peripheral Quantitative Computed Tomography in Human Long ...
    Dec 4, 2009 · The XCT 3000 produces a narrow beam by means of an X-ray tube (focal spot size 250 × 250 μm) operating at 60 kV (0.3 mA) and coupled with a ...
  35. [35]
    The pQCT "Bone Strength Indices" (BSIs, SSI). Relative mechanical ...
    Aug 5, 2025 · Bone size was measured using cortical area (CoA ( mm 2 )) and bone architecture using total area (ToA (mm 2 )) and polar moment of inertia (MoI ...
  36. [36]
    Associations Between Lean Mass, Muscle Strength and Power, and ...
    Apr 27, 2018 · ... PMI = polar moment of inertia; CSA = cross-sectional area; PC = periosteal circumference; CSMI = cross-sectional moment of inertia. a ...
  37. [37]
    High-resolution peripheral quantitative computed tomography
    In addition, HR-pQCT may be used for the monitoring of anti-osteoporotic therapy or for the assessment of mineral and bone disorder associated with CKD.
  38. [38]
    Full article: Comparison of bone microstructures via high-resolution ...
    HR-pQCT is useful for elucidation of the pathology of bone microstructures in patients with renal failure. Keywords: Chronic kidney disease · renal ...
  39. [39]
    Management of osteoporosis in chronic kidney disease
    Jul 16, 2025 · While further research is required before implementing it into routine clinical practise, HR-pQCT may be a more sensitive modality than DEXA in ...INTRODUCTION · BONE DISEASE IN CKD · MANAGEMENT OF BONE...
  40. [40]
    Peripheral quantitative computed tomography (pQCT) scan factsheet
    May 12, 2025 · A peripheral quantitative computed tomography (pQCT) scan is used to help diagnose osteoporosis. It measures the size, shape, and density of the arm and leg ...
  41. [41]
    High-resolution peripheral quantitative computed tomography
    Being a low-dose technique, HR-pQCT is suitable for monitoring effects of medications over time and/or individual trajectories of bone deterioration. Being a ...Missing: outpatient | Show results with:outpatient
  42. [42]
  43. [43]
    Visceral Adiposity and Hepatic Steatosis at Abdominal CT
    In women, a threshold of 185 cm2 for subcutaneous fat area was sensitive (85.9%) but not specific (49.7%) for metabolic syndrome. The visceral fat percentage ...
  44. [44]
    CT-based measurement of visceral adipose tissue volume as a ...
    Oct 20, 2023 · CT-based measurement of VAT volume may be a valuable tool for evaluating metabolic risk factors among individuals with prediabetes.
  45. [45]
    Emphysema detection by qualitative and quantitative analysis ... - PMC
    Oct 23, 2025 · Quantitative CT (QCT) low-attenuation area (LAA), defined by a density less than –950 HU or less than –910 HU, is a widely accepted measurement ...Missing: protocols | Show results with:protocols
  46. [46]
    Quantitative computed tomography and visual emphysema scores
    Computed tomography (CT) visual emphysema score is a better predictor of mortality than single quantitative CT emphysema measurements in COPD.
  47. [47]
    Role of AI and 3D quantitative computed tomography in obstructive ...
    Jun 10, 2025 · This study aimed to evaluate the usefulness of AI and three-dimensional (3D) quantitative CT in the assessment of lung volume, the wall thickness of airways, ...
  48. [48]
    COPD Imaging Phenotypes Assessment by Using Quantitative CT ...
    Apr 28, 2025 · The emphysema was determined by evaluating the low attenuation area (values lower than −950 hU). Total lung capacity (TLCCT) was also ...
  49. [49]
    Quantification of Liver Fat Content With Unenhanced MDCT
    More specifically, the linear conversion would indicate attenuation thresholds of 17.8 HU for severe and 42.1 HU for moderate steatosis. For patients without ...Missing: QCT | Show results with:QCT
  50. [50]
    CT-based Hounsfield unit values reflect the degree of steatohepatitis ...
    Mar 17, 2023 · In our study, the HU values on CT were useful in quantifying and stratifying liver fat contents in patients with low-grade hepatic steatosis, ...<|separator|>
  51. [51]
    Reference distributions of aortic calcification and association with ...
    Jun 9, 2023 · Recent research has demonstrated that aortic calcification scores can predict cardiovascular events and may outperform the Framingham Risk ...Missing: QCT | Show results with:QCT
  52. [52]
    Coronary Artery Calcium Scoring: Current Status and Future Directions
    Jun 3, 2022 · CAC scoring is currently recommended for use in asymptomatic individuals to predict the risk of developing cardiovascular diseases and the ...Missing: QCT | Show results with:QCT
  53. [53]
    Quantitative multi-energy CT in oncology: State of the art and future ...
    Multi-energy CT can generate multiple energy- and material-selective datasets with clinical value for tumor assessment.
  54. [54]
    Anatomy guided modality fusion for cancer segmentation in PET CT ...
    Apr 9, 2025 · This research addresses the gap by proposing an intermediate fusion approach that optimally balances the strengths of both modalities.Missing: QCT oncology
  55. [55]
    Current AI technologies in cancer diagnostics and treatment
    Jun 2, 2025 · Unlike CT and MRI, PET reveals tumor metabolism and helps define dose-escalation volumes, especially in head and neck cancers [58]. AI's ...
  56. [56]
    kVp, mA, and voxel size effect on 3D voxel-based superimposition
    KVp ranges between 60 and 90, mA between 2 and 15, and two options for voxel size, 300 and 500 μm. To limit radiation exposure, the scanner does not allow the ...Missing: pQCT Stratec
  57. [57]
    Quantitative computed tomography | Request PDF - ResearchGate
    Aug 6, 2025 · The technique is most commonly applied to 2D slices in the lumbar spine to measure trabecular bone mineral density (BMD; mg/cm(3)). Although not ...
  58. [58]
    Correction of QCT vBMD using MRI measurements of marrow ...
    The purpose of our study was to describe and validate a novel method to correct lumbar spine trabecular vBMD measurements for BMAT using chemical shift-encoded ...Missing: analysis pipeline semiautomated edge detection marching cubes
  59. [59]
    Deep-learning based 3D reconstruction of lower limb bones ... - NIH
    Apr 4, 2024 · The final 3D bone models were obtained by applying a Marching Cubes algorithm [13] to the 3D binary output arrays. Surgery planning. Finally ...Missing: ACT | Show results with:ACT
  60. [60]
    Update on the Clinical Application of Quantitative Computed ...
    Aug 14, 2014 · To perform QCT, a standard CT scanner with an external bone mineral calibration phantom underneath the patient is used and density values ...<|control11|><|separator|>
  61. [61]
    Radiation exposure in X-ray-based imaging techniques used in ...
    Jun 18, 2010 · Peripheral QCT is associated with a low radiation dose because radiosensitive organs are distant from the primarily exposed area. Studies show ...Missing: FOV | Show results with:FOV
  62. [62]
    Comparative evaluation of accuracy, precision, and radiation dose ...
    May 12, 2025 · Mindways QCT, a classic BMD assessment system, is widely used clinically for BMD measurement (12, 13, 15, 16) and is used as control to evaluate ...Missing: features | Show results with:features
  63. [63]
    Guidelines for ALARA – As Low As Reasonably Achievable - CDC
    Feb 26, 2024 · ALARA means avoiding exposure to radiation that does not have a direct benefit to you, even if the dose is small.
  64. [64]
    [PDF] Patient Gonadal and Fetal Shielding in Diagnostic Imaging - AAPM
    Should we still shield pediatric or pregnant patients? Fetal and gonadal shielding should not be used by default, regardless of the patient's age, sex, or.Missing: ALARA principle QCT
  65. [65]
    Quality and Safety in Medical Imaging During Pregnancy and ...
    Oct 1, 2024 · Certainly, a benefit-risk assessment is required when caring for the ill or injured pregnant patient and one must adhere to the ALARA principle ...
  66. [66]
    ACR Statement on JAMA CT Scan Radiation Study (Smith-Bindman ...
    Apr 14, 2025 · There are no published studies directly linking CT scans (even multiple CT scans) to cancer. Americans should not forgo necessary, life-saving ...<|control11|><|separator|>
  67. [67]
    Projected Lifetime Cancer Risks From Current Computed ...
    This study found that at current utilization and radiation dose levels, CT examinations in 2023 were projected to result in approximately 103 000 future ...
  68. [68]
    Automatic phantom-less QCT system with high precision of BMD ...
    Feb 5, 2022 · The aim of this study is to validate the accuracy and precision of one newly-developed automatic PL-QCT system to measure spinal bone mineral density (BMD) and ...
  69. [69]
    [PDF] QCT vs. DXA: What's the Score?
    At the hip, QCT is used to produce both areal BMD measurements in g/cm2 and. DXA-equivalent T-scores. However, at the spine, QCT produces a true volumetric ...
  70. [70]
    Improved prediction of incident vertebral fractures using ...
    Feb 21, 2019 · The predictability of incident vertebral fractures was good by BMDQCT (AUC = 0.76; 95% CI, 0.64–0.89) and non-significant by T-scores.Missing: percentage | Show results with:percentage
  71. [71]
    Opportunistic screening for osteoporosis by abdominal CT in a ...
    Apr 1, 2023 · Routine abdominal CT can be used to opportunistically screen for osteoporosis without additional cost or radiation exposure.<|separator|>
  72. [72]
    Pricier, Questionable Bone Density Scan Growing in Use
    Apr 14, 2022 · From 2015 to 2019, providers submitted 32,694 claims for QCT bone mineral density studies performed for fee-for-service beneficiaries. The ...
  73. [73]
    Understanding Quantitative Computed Tomography (QCT) for Bone ...
    Sep 3, 2024 · Contraindications for QCT Bone Density Scans · Have recently undergone a test involving barium, iodine, or other contrast materials · Are pregnant ...
  74. [74]
    Bone imaging modality precision and agreement between DXA ...
    Dec 3, 2024 · Peripheral QCT (pQCT) technologies are 3D imaging modalities that provide compartment-specific estimates of density, mass, geometry, ...
  75. [75]
    Evaluation of Image Quality of Overweight and Obese Patients in CT ...
    May 3, 2023 · ... obese patients, as they are commonly degraded by increased image noise and artefacts, i.e., beam hardening and photon starvation (7-9). This ...Missing: QCT | Show results with:QCT
  76. [76]
    Developing Cut-off Values for Low and Very Low Bone Mineral ...
    Aug 16, 2024 · Variations in mean BMD values between ethnicities exist, differing 13–40% depending on body site and sex [17, 25]. Budoff et al. [15] assessed ...
  77. [77]
    Quantitative CT lumbar spine BMD cutpoint value for classifying ...
    Jun 21, 2024 · For older Chinese men, the QCT lumbar spine BMD cutpoint for osteoporosis is 45-50 mg/ml, the same as for Chinese women.Missing: variations | Show results with:variations
  78. [78]
    The effect of fat on the measurement of bone mineral density ... - PMC
    Mar 12, 2011 · Their results suggested that DXA scanning in obese patients can have substantial errors, overestimating BMD by 1 or 2 T score units and causing ...
  79. [79]
    Long-Term Reproducibility of BMD-Measurements with Clinical QCT ...
    Oct 16, 2024 · We compared gold standard simultaneous calibration with asynchronous calibration methods, assessing mid-term (12 weeks) and long-term (1.5 years) ...Missing: formula | Show results with:formula
  80. [80]
  81. [81]
    [PDF] 2019-Official-Positions-Adult-1.pdf (iscd.org)
    Comply with radiation surveys and regulatory government inspections, radiation surveys and regulatory requirements ... Thresholds for low lean mass from consensus ...Missing: 2018 reduction
  82. [82]
    Proximal Femoral Structure and the Prediction of Hip Fracture in ...
    Proximal Femoral Structure and the Prediction of Hip Fracture in Men: A Large Prospective Study Using QCT ... [HR] per SD decrease: 3.2; 95% CI: 2.2-4.6 ... AUC ...
  83. [83]
    Quantitative imaging methods in osteoporosis - Oei
    This review provides an overview of various quantitative imaging techniques based on different radiological modalities utilized in clinical osteoporosis care ...Computed Tomography... · Mriother Section · Vertebral Fracturesother...
  84. [84]
    Other diagnostic tools | International Osteoporosis Foundation
    TBS predicts hip and major osteoporotic fractures independently of BMD and clinical risk factors (CRFs) in postmenopausal and male osteoporosis[3]Shevroja E et ...Missing: criteria | Show results with:criteria
  85. [85]
  86. [86]
    Pre-screening for osteoporosis with calcaneus quantitative ... - Nature
    Aug 3, 2021 · Comparison of quantitative ultrasound and dual-energy X-ray absorptiometry for prediction of 10-year absolute risk of fracture among older ...
  87. [87]
    MRI-based vertebral bone quality score compared to quantitative ...
    Mar 7, 2023 · The objective of this study was to evaluate the correlation between VBQ scores and bone mineral density (BMD) measured by quantitative computer tomography (QCT ...
  88. [88]
    Assessment of bone density using the 1.5 T or 3.0 T MRI-based ...
    Recently published studies have revealed a correlation between MRI-based vertebral bone quality (VBQ) score and bone mineral density (BMD) measured using ...Missing: calcification | Show results with:calcification
  89. [89]
    MRI-based vertebral bone quality score as a novel bone status ...
    May 31, 2024 · Of note, the current study does not suggest that MRI replace DXA or QCT for the assessment of low BMD or osteoporosis. Instead, we believe that ...
  90. [90]
    Accuracy of plain radiography in detecting fractures in older ...
    Nov 3, 2020 · False- negative XR of the thoracic spine was reported in 30.7% (33 of 107)28 and 36%. (12 of 33)20 of patients, false- negative XR of the lumbar ...
  91. [91]
    Misdiagnosis of vertebral fractures on local radiographic readings of ...
    Osteoporotic vertebral fractures (VFs) are often misdiagnosed because asymptomatic and occurring in the absence of specific trauma.
  92. [92]
    A novel calibration of vertebral bone quality score for the evaluation ...
    Sep 29, 2025 · The opportunistic MRI-based VBQ scores can be used as an additional screening tool for identifying high-risk patients requiring further DEXA/QCT ...
  93. [93]
    MRI-based vertebral bone quality score for the assessment of ...
    Mar 29, 2023 · To explore the value of vertebral bone quality (VBQ) scores in diagnosing osteoporosis in patients with lumbar degeneration.Degenerative Group Condition · Bone Density Assessment · Modic Changes
  94. [94]
    [PDF] 2023 ISCD Official Positions Adult
    Comply with radiation surveys and regulatory government inspections, radiation surveys and regulatory requirements ... Thresholds for low lean mass from consensus.Missing: 2018 reduction
  95. [95]
    Opportunistic Quantitative CT Bone Mineral Density Measurement at ...
    Apr 15, 2016 · 11, 12 This tool uses a femoral neck BMD or T-score along with patient characteristics and risk factors to estimate the 10-year fracture risk.Patients And Methods · Dxa And Ct Acquisition · Results<|separator|>
  96. [96]
    Measurement of Bone Mineral Density - RACGP
    Mar 1, 2024 · The WHO international reference standard for osteoporosis diagnosis is a T-score of –2.5 or less at the femoral neck (FN).
  97. [97]
    The European Spine Phantom--a tool for standardization and quality ...
    We conclude that the ESP is suitable for daily quality assurance, cross-calibration of instruments and universal standardization.Missing: inter- | Show results with:inter-<|control11|><|separator|>
  98. [98]
    Accuracy, Linearity and Precision of Spine QCT vBMD Phantom ...
    The median precision error for L1-3 vBMD was 0.61 mg/cm3. Statistically significant differences in spine vBMD measurements between different scanners reinforce ...
  99. [99]
    Automatic phantom-less QCT system with high precision of BMD ...
    The aim of this study is to validate the accuracy and precision of one newly-developed automatic PL-QCT system to measure spinal bone mineral density (BMD) and ...Missing: placement verification
  100. [100]
    Reproducibility of CT-based opportunistic vertebral volumetric bone ...
    Aug 1, 2024 · This study aimed to provide comprehensive information on the reproducibility of vBMD measurements performed by a fully automated convolutional neural network ...
  101. [101]
    Comparative evaluation of accuracy, precision, and radiation dose ...
    May 11, 2025 · Low-dose iCare QCT exhibited high accuracy and precision in measuring lumbar spine BMD, achieving an approximately 85% reduction in radiation dose.<|control11|><|separator|>
  102. [102]
    [PDF] Precision Assessment and Radiation Safety - ISCD
    Calculated precision error, %CV, has been published for the total hip (0.81.69%), PA spine (1.01.2%), femoral neck (1.112.2%) and trochanter (1.161.5%) (69).
  103. [103]
    [PDF] Calculation of the Least Significant Change Value of Bone ... - kjnmt
    When a 95% confidence interval is applied, the least significant change (LSC) value is calculated by multiplying the precision error value by 2.77. Exceeding ...