Fact-checked by Grok 2 weeks ago

80 Plus

The 80 PLUS® certification program is a voluntary performance specification and independent certification initiative for internal power supply units (PSUs) in computers and servers, designed to promote energy efficiency by requiring certified products to achieve at least 80% efficiency at 20%, 50%, and 100% of their rated load (with higher thresholds for advanced levels), alongside a power factor of 0.9 or greater at 50% load. Administered by CLEAResult, the program evaluates PSUs under standardized testing protocols across various voltage inputs (such as 115V for desktops and 230V/277V/380V/480V for data centers and industrial applications), helping manufacturers, utilities, and consumers reduce electricity waste and operational costs in computing environments. It is recognized internationally, including by ENERGY STAR® for compliance in desktop and server categories, and applies to a wide range of PSU form factors from consumer-grade to high-wattage data center units. Initiated in 2003 through collaboration among electric utilities, the computer industry, and efficiency advocates—beginning with the program's concept announcement at the ACEEE Market Transformation Symposium and sponsorship by the Northwest Energy Efficiency Alliance—the 80 PLUS program issued its first certification to a market-ready PSU from Seasonic that same year. Early adoption accelerated with major manufacturers like (certifying four PSUs in 2003) and (joining by 2007), while integrations with versions 4.0 (2007) and 5.0 (2010) mandated 80 PLUS levels for desktops, driving widespread industry uptake. Over time, the program has evolved to address global standards, introducing specialized specifications for European (230V) and environments (e.g., 380V DC in 2022, 480V in 2024), and enhancing transparency by including no-load and 5% load efficiency data in certificates since 2023. The program features seven progressive certification levels—Standard, Bronze, Silver, Gold, Platinum, Titanium, and Ruby—each with escalating efficiency requirements tested at multiple load points to ensure optimal performance across typical usage scenarios. involves lab testing, with fees ranging from $3,500 to $8,000 USD depending on the level and PSU category, and all results are publicly accessible via an searchable by manufacturer, wattage, or rating. The Ruby level, introduced in 2025 as the most stringent to date, targets PSUs with at least 96.5% at 50% load under 230V/277V AC-DC inputs, reflecting ongoing advancements in power delivery for . Efficiency values are for 115V/230V inputs unless specified; 10% load applies to (90%) and higher for low-load optimization.

Overview

Definition and Purpose

The 80 Plus program is a voluntary initiative for internal units (PSUs) used in computers, servers, and industrial equipment, verifying that these units achieve a minimum of 80% efficiency in converting (AC) to (DC) at specified load levels of 20%, 50%, and 100%, alongside a of 0.9 or greater at 50% load. This enables manufacturers to demonstrate the energy performance of their PSUs through independent testing, fostering the adoption of higher-efficiency designs in the power electronics market. The primary purpose of the 80 Plus program is to minimize waste in and applications by encouraging PSUs that operate more efficiently across typical usage scenarios, thereby reducing consumption for end-users and mitigating the environmental footprint associated with power generation and transmission. It addresses the escalating energy demands of the sector, where inefficient PSUs historically contributed significantly to overall system power losses, promoting broader goals without mandating compliance. In scope, the program targets PSUs for desktops, workstations, servers, and data centers, with testing protocols tailored to these applications under various voltage inputs. Unlike broader efficiency standards such as , which certify entire devices or systems for overall performance, 80 Plus concentrates exclusively on the PSU component's conversion , serving as a specialized integrated into wider regulatory frameworks. The has been administered by CLEAResult since 2018, following prior management by Ecos Consulting.

Benefits

Users of 80 Plus-certified power supplies benefit from lower electricity costs due to higher , which reduces the amount of power drawn from the wall outlet for the same output. Additionally, these PSUs generate less during operation, resulting in cooler system temperatures, reduced fan noise, and potentially longer lifespan for internal components due to decreased . Manufacturers gain competitive advantages from 80 Plus certification, as it differentiates their products in the market and demonstrates commitment to , boosting consumer confidence. The certification also facilitates compliance with international regulations, such as the Union's Lot 9 energy efficiency requirements for internal power supplies in enterprise servers and data centers, and the program for computers, enabling eligibility for listings and incentives. On the environmental front, 80 Plus-certified PSUs contribute to reduced by minimizing energy waste and associated from . Higher certification levels, such as or , support goals in sectors like centers by lowering overall heat output and power demands. Since its , the 80 Plus program has certified thousands of PSU models, leading to significant cumulative global energy savings and reductions in environmental impact.

History

Origins

The 80 Plus program was created in 2004 by Ecos Consulting, an energy efficiency firm, as a voluntary initiative to promote higher standards for units (PSUs) in computers and servers. The effort was driven by the recognition that PSUs in early s and data centers were highly inefficient, typically achieving only 65% to 70% efficiency during AC-to-DC conversion, which led to substantial energy waste equivalent to 30% to 50% more power draw than necessary. With personal computer adoption surging globally, the program sought to establish a baseline of 80% efficiency at key load levels (20%, 50%, and 100%) to curb unnecessary electricity consumption and associated environmental impacts, potentially saving 15% to 25% in overall system energy use. The program was officially launched in spring 2004, with its inaugural announcement made in March at the American Council for an Energy-Efficient Economy (ACEEE) Market Transformation Symposium. Initial efforts focused exclusively on desktop PSUs, requiring certified units to meet the 80% efficiency threshold while incorporating power factor correction to minimize harmonic distortion. Ecos Consulting developed the certification framework in collaboration with the (EPRI), which handled independent testing, to ensure credibility and market acceptance. Early adoption gained momentum through strategic partnerships with industry stakeholders and utilities, including the Natural Resources Defense Council (NRDC), , the Northwest Energy Efficiency Alliance (NEEA), and Pacific Gas & Electric Company. worked closely with EPRI to refine PSU specifications, while the U.S. Environmental Protection Agency (EPA) provided support to integrate efficiency standards into broader procurement and regulatory frameworks. The first market-ready 80 Plus certified PSU emerged in February 2005 from Seasonic, marking the beginning of commercial availability and demonstrating the feasibility of the program's goals.

Evolution

Following its initial launch in 2004, the 80 Plus underwent significant expansions to encourage progressively higher standards in units (PSUs). In 2007, the introduced the , Silver, and Gold levels to differentiate and incentivize PSUs achieving efficiencies above the baseline 80% threshold at typical loads, aligning with growing demands from utilities and manufacturers for reduced energy waste in and applications. These tiers were integrated into specifications, with Version 4.0 requiring basic 80 Plus for desktops effective July 1, 2007, and Version 5.0 mandating or better starting July 1, 2009. The level followed in 2009, setting a new benchmark of at least 90% at 20% and 100% loads and 92% at 50% load for 115V inputs, further promoting advanced designs in and . To address the unique needs of infrastructure, the certification was launched in 2012 specifically for PSUs, demanding 90% at 10% load, 94% at 20%, 96% at 50%, and 91% at 100% for 230V inputs, which helped drive adoption in high-density computing environments. This was extended to PSUs in alongside the introduction of a 230V , enhancing the program's global applicability and alignment with regional voltage standards. Ownership and administration evolved to support broader reach; originally developed by Consulting, the program transitioned under Plug Load Solutions (part of Ecova) by the early before CLEAResult assumed management in 2018, facilitating international expansion and third-party testing protocols that boosted recognition in and . Recent developments have focused on ultra-high-efficiency needs for emerging technologies, particularly in data centers. In 2022, the program added a 380V DC specification tailored for hyperscale facilities, followed in 2023 by requirements to report no-load and 5% load efficiencies on certificates, along with 277V and 230V EU Titanium options for redundant server setups. The Ruby level was introduced in January 2025 by CLEAResult, endorsed by The Green Grid, targeting AI and data center PSUs with stringent criteria of at least 96.5% efficiency at 50% load and 90% across the full load range for 230V, 277V, 480V AC-DC, and 380V DC inputs, emphasizing redundant configurations to minimize energy loss in high-power AI workloads. By 2025, the program has certified thousands of PSU models worldwide, with increased emphasis on redundant units for AI data centers and integration into global benchmarks such as the EU Code of Conduct for Data Centre Energy Efficiency, where 80 Plus ratings inform best practices for power supply optimization. The 20th anniversary in 2024 underscored the program's impact, with lifetime energy savings from certified PSUs contributing to reductions equivalent to hundreds of terawatt-hours globally through widespread adoption.

Certification Levels

Basic and Intermediate Levels

The basic and intermediate levels of the 80 Plus represent the entry points for power supply unit (PSU) efficiency, targeting consumer computers with moderate power demands. These levels—Standard, Bronze, Silver, and —set minimum efficiency thresholds at key load points to reduce waste and heat generation in everyday computing scenarios. Certified PSUs at these tiers are designed primarily for 115V internal applications, such as computers and workstations, where power outputs typically range from 300W to 600W. The level serves as the baseline , requiring a minimum of 80% at 20%, 50%, and 100% of the rated load, along with a of at least 0.90. This entry-level standard ensures that even budget-oriented PSUs meet a fundamental efficiency benchmark, making it suitable for basic systems used for browsing, office work, and light tasks. All higher certification levels build upon this foundation, but Standard remains the most accessible for cost-sensitive builds. Introduced in 2007, the Bronze level raises the bar for consumer PCs by mandating 82% at 20% and 100% loads, and 85% at 50% load, also requiring a of ≥0.90. This certification offers approximately 5-10% better real-world compared to under typical operating conditions, where loads often hover around 50%, leading to modest savings and reduced costs for everyday users. Bronze-rated PSUs are common in entry-level to mid-range consumer desktops, providing a balance of affordability and improved performance over non-certified units. The Silver level targets gaming and enthusiast builds, requiring 85% at 20% and 100% loads, and 88% at 50% load, with the same power factor minimum. This tier emphasizes a cost-effective step up in without the of higher levels, making it for systems with discrete graphics cards or multi-core processors that experience variable loads. Silver helps maintain cooler operation and longevity in moderately demanding setups, though it is less prevalent than Bronze or due to market preferences. Gold certification, also introduced around 2007-2008 as part of the program's expansion, demands 87% at 20% and 100% loads, and 90% at 50% load, maintaining the ≥0.90 . Widely adopted in high-end desktops, this level is often specified by original equipment manufacturers (OEMs) such as and for their premium systems, ensuring reliable performance under sustained loads from , content creation, or productivity workloads. Gold PSUs in the 300-600W range exemplify the tier's focus on energy that supports modern component demands while minimizing operational costs.
Certification Level20% Load Efficiency50% Load Efficiency100% Load Efficiency
Standard80%80%80%≥ 0.90
Bronze82%85%82%≥ 0.90
Silver85%88%85%≥ 0.90
87%90%87%≥ 0.90
These efficiency requirements apply specifically to non-redundant, 115V internal PSUs tested under standardized conditions, promoting broader adoption in residential and small environments.

Advanced Levels

The advanced levels of the 80 PLUS certification—, , and —represent the highest tiers of for units (PSUs), targeting demanding applications where minimal energy loss is critical. These certifications require efficiencies exceeding 90% across key load levels, with stricter thresholds than lower tiers, enabling reduced operational costs and output in high-density environments. Platinum certification sets a benchmark for premium consumer and entry-level server PSUs, demanding at least 90% efficiency at 20% load, 92% at 50% load, and 89% at 100% load for 115V internal non-redundant units, alongside a power factor of ≥0.95. For 230V EU internal non-redundant PSUs, requirements rise to 92% at 20% load, 94% at 50% load, and 90% at 100% load. In redundant configurations for 277V/480V systems, efficiencies are 90% at 20% load, 94% at 50% load, and 91% at 100% load. These specifications support premium desktops and entry-level servers by minimizing heat generation in compact, dense builds, thereby enhancing reliability and cooling efficiency. Introduced in 2012 with a focus on servers, certification elevates standards further, requiring 90% efficiency at 10% load, 92% at 20% load, 94% at 50% load, and 90% at 100% load for 115V internal non-redundant PSUs, with a of ≥0.95. For 230V EU and 277V/480V redundant units, efficiencies reach 90% at 10% load, 94% at 20% load, 96% at 50% load, and 91% at 100% load. This level is widely adopted in hyperscale data centers for its ability to handle intensive workloads while optimizing energy use and reducing demands. The Ruby certification, added in 2025, targets redundant PSUs in data centers operating at 230V, 277V, 480V AC-, and 380V , with requirements of 90% at 5% load, 91% at 10% load, 95% at 20% load, 96.5% at 50% load, and 92% at 100% load, alongside a of ≥0.96. This represents the program's most stringent standard in over a decade, surpassing by 0.5% at 50% load and incorporating a 5% load threshold to address low-utilization scenarios common in modern infrastructure. is designed for high-power redundant systems in and workloads, particularly in 380V architectures where efficiencies exceed 96% at typical operating points, supporting scalable, energy-intensive environments.
Certification LevelVoltage Type5% Load10% Load20% Load50% Load100% LoadPower Factor
Platinum (115V Non-Redundant)115V--90%92%89%≥0.95
Titanium (115V Non-Redundant)115V-90%92%94%90%≥0.95
Ruby (230V/277V/480V/380V DC Redundant)230V+90%91%95%96.5%92%≥0.96
These advanced levels are primarily applied in data centers and industrial settings, where Platinum suits entry servers, Titanium powers hyperscale operations, and Ruby enables efficient handling of AI/ML demands in redundant, high-voltage systems.

Technical Specifications

Efficiency Requirements

The efficiency of a power supply unit (PSU) under the 80 Plus program is calculated using the η = (P_out / P_in) × 100%, where η represents as a , P_out is the total real DC output power, and P_in is the real AC input power. This measurement accounts for all output rails and auxiliary circuits, ensuring a comprehensive of energy conversion. Efficiency is evaluated at specific load points relative to the PSU's rated output power: 20%, 50%, and 100% for standard certification levels, with an additional 10% load point required for higher tiers such as and Ruby. Note that the specific minimum efficiency percentages required at each load point vary depending on the voltage category (e.g., 115V, 230V) and whether the PSU is non-redundant or redundant, as detailed in the specifications. The level is determined by the PSU meeting or exceeding the minimum efficiency thresholds at each of the specified load points for the targeted rating. Testing occurs under controlled conditions, including an ambient room temperature of 23°C ± 5°C and specific nominal input voltages (such as 115 V/60 Hz) corresponding to the PSU category, unless otherwise specified for international or higher-voltage models. Measurements are conducted at these nominal input voltages without adjustments to active power factor correction during the efficiency tests, focusing on inherent performance. The program's methodology emphasizes real-world operating scenarios, particularly around 50% load, which represents typical usage, thereby differentiating certified PSUs from those claiming only peak without load-specific validation.

Additional Criteria

Beyond the core metrics, the 80 Plus certification program incorporates requirements for (PF), which measures the of power usage by comparing real power to apparent power. The is calculated using the formula \text{PF} = \frac{P_{\text{real}}}{V_{\text{rms}} \times I_{\text{rms}}}, where P_{\text{real}} is the real power in watts, V_{\text{rms}} is the root-mean-square voltage, and I_{\text{rms}} is the root-mean-square . High values indicate minimal reactive power and reduced harmonic distortion in the electrical system, achieved through power factor correction circuits that align input with voltage. Power factor thresholds vary by certification level and load points to ensure consistent performance across operating conditions. For the Standard level, a minimum PF of 0.90 is required at 50% load for 115V and at 20% and 50% loads for 230V. For Bronze, Silver, and Gold levels, ≥0.90 PF is required at 50% load across applicable voltages. Platinum certification demands ≥0.95 PF at 50% load. Titanium requires ≥0.95 PF at 20% and 50% loads. The highest Ruby level sets PF at ≥0.90 for low loads of 5% and 10%, escalating to ≥0.96 at 20%, 50%, and 100% loads, targeting high-efficiency applications.
Certification LevelPF Requirement at Loads
Standard≥0.90 at 50% (115V); ≥0.90 at 20%, 50% (230V)
, Silver, ≥0.90 at 50%
≥0.95 at 50%
≥0.95 at 20%, 50%
≥0.90 at 5%, 10%; ≥0.96 at 20%, 50%, 100%
The program also addresses diverse operational environments through specific voltage categories, tailoring testing to regional and application-specific needs. The 115V category covers internal non-redundant power supplies for desktops and use, common in North American markets. The 230V category applies to internal desktops and internal redundant setups for s. Higher-voltage options include 277V and 480V for internal redundant data center power supplies, while the 380V category supports internal redundant data center configurations. These categories allow for adjustments in evaluation at high-line voltages to better reflect performance in and environments, though the primary benchmarks remain consistent across categories. Additional specifications emphasize testing rigor for higher tiers without mandating other performance aspects. Advanced levels like and require evaluation at a minimum 10% load (along with 5% for Ruby), ensuring reliability under light-load conditions typical in modern computing. However, the program sets no standards for hold-up time—the duration a maintains output after input power loss—or output voltage , highlighting limitations in comprehensive power quality assessment.

Certification Process

Application Procedure

Manufacturers initiate the 80 Plus by creating an account on the CLEAResult online portal dedicated to the program. After registration, applicants select the relevant power supply unit (PSU) category—such as 115V internal desktop, 230V EU internal, or variants—and specify the target efficiency level, ranging from standard 80 Plus to or higher designations like . This step ensures the application aligns with the appropriate testing protocol for the product's intended market and voltage requirements. Following selection, applicants complete an online questionnaire detailing product specifications, including rated wattage, input voltage range, and basic topology details. Manufacturers must also submit at least two production, pre-production, or reference design samples for independent verification. A one-time license fee of $5,000 USD is required, plus initial testing fees ranging from $6,000 to $8,000 USD per model depending on the category (e.g., $6,500 USD for 115V and 230V internal PSUs). fees are $3,500 USD per model, with additional charges like $100 USD for return shipping and $500 USD for test report revisions. The overall review timeline spans approximately 4 weeks from submission of complete documentation and samples, culminating in a preliminary assessment before lab validation proceeds. Since 2007, the program has been accessible to global manufacturers, enabling international participation across diverse voltage standards and markets.

Testing and Validation

The testing and validation process for 80 Plus is conducted by CLEAResult, the program's , utilizing high-precision in controlled environments to ensure accurate efficiency measurements. Approved testing facilities, often labs partnered with CLEAResult, employ calibrated analyzers such as the Yokogawa WT5000E for 115V and 230V testing (with ±0.01% accuracy) and the Hioki PW6001-16 for higher voltages like 230V, 277V, and 380V (with ±0.02% accuracy), alongside shunts and transformers (e.g., Hioki CT6841A models ranging from 20A to 1000A) for precise measurement. These instruments maintain below 0.5%, verified through semi-annual tests that compare results against reference standards to confirm consistency within this threshold. The protocol begins with manufacturers submitting at least two production or pre-production units to CLEAResult following the . Testing simulates real-world operating conditions by applying DC loads at key percentages of the unit's rated output—typically 10%, 20%, 50%, and 100% for most levels, with additional points like 2% (or 10W minimum), 5%, and 0% (no-load) for higher certifications—using programmable load banks such as 63640-150-60 or 63610-80-20. At each load level, the unit operates in steady-state for 15 minutes to stabilize, during which input power (P_in, AC from a stable source via a or LISN with 50μH and 1μF ) and output power (P_out, DC) are measured continuously, voltage, , and power every 1 to 250 milliseconds. is calculated as (P_out / P_in) × 100%, with also assessed (requiring ≥0.9 or ≥0.95 depending on the level); if the first unit fails or borders a threshold, the second unit undergoes targeted retesting at those points for confirmation. Upon completion, CLEAResult's technical team reviews all and reports for compliance with the specified and criteria across voltage classes (e.g., 115V, 230V). Passing units receive official certification, granting licensees permission to use the corresponding 80 Plus logo (e.g., , ) in marketing materials at no additional cost beyond testing fees. Certified models are then listed in the 80 Plus database on the official website, including details like manufacturer, model, wattage, and typical , enabling consumers and stakeholders to verify compliance. To maintain program integrity, CLEAResult conducts periodic spot tests on market samples and a challenge process where discrepancies can trigger revalidation of production units. In 2025, the program introduced the level for PSUs, extending testing protocols to higher efficiencies up to 96.5% while upholding the same rigorous validation standards.

Criticisms

Misleading Practices

One common deceptive practice in the marketing of 80 Plus certified power supplies involves conflating peak power ratings with continuous power capabilities. Manufacturers may advertise a unit as, for example, a "1000W 80 Plus" power supply, but the actual sustained output under continuous load is often significantly lower, such as 700W, leading consumers to believe the unit can handle higher ongoing demands than it can reliably support. The 80 Plus program, however, certifies efficiency based on continuous load testing at 20%, 50%, and 100% of the rated continuous wattage, not short-term peaks, which can mislead buyers into selecting underpowered units for their systems. Another misleading tactic is the use of vague or unspecified certification levels in labeling and . Some products are marketed simply as "80 Plus " without indicating the tier (e.g., , , or ), which can imply a higher standard than the basic 80 Plus level, potentially violating general () guidelines on deceptive that require claims to be clear, truthful, and substantiated. This ambiguity exploits consumer familiarity with the 80 Plus brand while downplaying the actual performance tier, as higher levels like require efficiencies above 87% at typical loads compared to the basic level's 80%. Examples of such practices include the application of or unauthorized 80 Plus logos on uncertified units, particularly among supplies. In the 2010s, several models from various brands were found to display fabricated 80 Plus s, such as rebranded units assuming certification from their (OEM) without independent testing or premature labeling based on unverified internal results. More recently, in , the Thermaltake Toughpower GF A3 750W was criticized for featuring a 80 Plus alongside a silent platform change in manufacturing (from one OEM to another), without updating product labeling or to reflect the differences in quality and performance. These practices mislead consumers into overpaying for inefficient or unreliable units, as the 80 Plus is often perceived as a guarantee of quality and efficiency beyond just energy savings. Misuse of the logo has led to delistings from the 80 Plus database and public exposures by reviewers, prompting some manufacturers to remove false claims or pursue proper after scrutiny.

Program Limitations

The 80 Plus certification program focuses narrowly on AC-to-DC conversion measured at 20%, 50%, and 100% of rated capacity for all levels, with an additional 10% load point for Titanium and Ruby levels, disregarding essential PSU quality metrics such as voltage ripple, , and hold-up time. Voltage ripple refers to unwanted AC fluctuations on the DC output that can degrade component , while assesses how quickly the PSU stabilizes voltage during sudden load changes, and hold-up time measures the duration the PSU sustains output after AC power loss. This limited evaluation allows PSUs to earn high ratings despite poor performance in these areas, and independent reviews have shown that even certified units can fail reliability benchmarks under real-world stress like high temperatures or prolonged full loads. Established in , the program's testing protocols have not evolved sufficiently to address modern PSU architectures, such as LLC resonant converters that achieve peak between 30% and 80% load rather than at the fixed points assessed. It also overlooks advancements like (GaN) semiconductors, which enable higher switching frequencies and lower losses in compact designs, without specific tests for their integration or associated gains. By 2025, further critiques highlight gaps in evaluating modular cabling losses—where detachable cables introduce and —and with USB Power Delivery (USB-PD) standards for integrated peripheral charging, leaving consumers without assurance on overall system performance in multi-device environments. In 2024, major manufacturers like announced a shift away from 80 Plus certifications toward Cybenetics ETA ratings, which assess efficiency across the full load curve (including 5% and ), noise levels, and other quality factors, underscoring criticisms of 80 Plus's outdated and limited scope. The certification's high costs, ranging from $3,500 to $8,000 USD per model based on wattage and input voltage requirements, deter smaller manufacturers from participating, restricting the program to larger firms. As a voluntary initiative without regulatory enforcement, this results in limited adoption, with a significant portion of new PSUs entering the market uncertified and potentially less efficient. Compared to emerging standards like 3.0, which mandates Cybenetics efficiency testing across a wider load range (including 5VSB and vampire power consumption), the 80 Plus program appears inadequate for today's high-power components. Proposed updates include expanding tests to cover voltage ripple caps (e.g., under 100 mV on 12V rails), hold-up time (at least 16-20 ms), and validation for the 12VHPWR connector to handle GPU power excursions up to 600W, thereby bridging gaps with standards like Cybenetics ETA that provide more holistic assessments.

References

  1. [1]
    80 PLUS certification specifications and ratings | CLEAResult
    80 PLUS offer seven levels of certification for internal power supplies at increasing ratings of energy efficiency ranging from Standard to Ruby.
  2. [2]
    80 PLUS certification program milestones and FAQs - CLEAResult
    Learn more about 80 PLUS certification program timelines and milestones Testing FAQs and Testing protocols.Missing: history | Show results with:history
  3. [3]
    80 PLUS® | PSU Efficiency Certification Program - CLEAResult
    80 PLUS® is our certification program for internal power supply units (PSUs), offering up to seven levels of certification for increasing energy efficiency.Program Details · 80 PLUS · Certified PSUs · Bronze
  4. [4]
    [PDF] 80 PLUS®: Market Impacts and Lessons Learned - ACEEE
    In March 2004, Ecos Consulting (Ecos) announced an ambitious program called 80. PLUS during ACEEE's Market Transformation Symposium.Missing: CLEAResult | Show results with:CLEAResult
  5. [5]
    [PDF] Right Sizing and Designing Efficient Power Supplies - Energy Star
    Right-Sizing Pays for Most or All of the Extra. Cost of a Well-Designed 80 Plus Power Supply. Cost Comparison Today vs 80 Plus. 0. 0.5. 1. 1.5. 2. 2.5. 3. 3.5.
  6. [6]
    [PDF] 80 PLUS computer power supply | CalMTA
    Also, certification of power supplies was conducted by the EPRI (later by. CLEAResult). To have a PSU certified, manufacturers paid a $400 fee for each model ...
  7. [7]
    Is an energy efficient power supply (80 PLUS) worth it for my ...
    Mar 31, 2011 · ... year. Annual savings = $7.88 / year. This makes the $20 for the more efficient PSU something of a toss-up: the energy savings recover the cost ...
  8. [8]
  9. [9]
    Lot 9 regulations overview - Ynvolve
    Jul 19, 2024 · Internal power supplies: Lot9 mandates that internal power supplies must meet specific efficiency criteria, typically 80 Plus certification ...<|control11|><|separator|>
  10. [10]
    80 Plus Certification Service Provider - GTG Group
    The 80 Plus certification helps reduce greenhouse gas emissions by promoting energy efficiency;; An 80 Plus certified PSU means lower electricity bills, as it ...Missing: definition | Show results with:definition
  11. [11]
    None
    Nothing is retrieved...<|control11|><|separator|>
  12. [12]
    80 plus: a strategy for reducing the inherent environmental impacts ...
    Research by Ecos Consulting and EPRI Solutions between 2004 and 2006 indicates that today's desktop and server PSUs are typically 65% to 70% efficient in ...
  13. [13]
    Everything you need to know about our 80 Plus® certification program.
    Apr 12, 2022 · 80 PLUS is a performance specification and certification program for internal power supply units (PSUs). Every certified product and its testing report is ...Missing: history | Show results with:history
  14. [14]
    Power supply ratings explained: the 80 Plus certification system in ...
    Mar 28, 2025 · Many (but not all) power supplies are rated on the 80 Plus certification system, and there are six different labels ascribed to a PSU. These ...
  15. [15]
    Power Supply Units Made Easy: 80 Plus Ratings | Overclockers UK
    Jun 14, 2021 · In 2012, the Titanium rating was introduced, operating at an amazing ... 1000W+: 80 PLUS Titanium. Asus ROG THOR 1600W 80 Plus Titanium ...
  16. [16]
    [PDF] NEEA Market Progress Evaluation Report #3: 80 PLUS
    The 80 PLUS program certifies energy-efficient power supplies for desktop personal computers. (PCs) and servers. As a sponsor of 80 PLUS, the Northwest ...
  17. [17]
    TPG Growth and The Rise Fund Complete Acquisition of CLEAResult
    Aug 8, 2018 · TPG Growth and The Rise Fund are co-investors in acquiring the company from General Atlantic, a leading global growth equity firm.
  18. [18]
    Navitas exceeds new 80 PLUS 'Ruby' certification for highest level of ...
    Mar 18, 2025 · The 'Ruby' certification was announced in January by 80 PLUS's administrating body CLEAResult following its endorsement by the Green Grid ...
  19. [19]
    Power supplies exceed 80 PLUS Ruby certification - EDN Network
    Mar 19, 2025 · The new Ruby certification, announced in January 2025 by 80 PLUS's administrating body, CLEAResult, following its endorsement by the Green Grid ...
  20. [20]
    [PDF] 2024 Best Practice Guidelines for the EU Code of Conduct on Data ...
    This document is a companion to the EU Code of Conduct on Data Centre Energy Efficiency and provides the full list of identified Best Practices for data centre ...
  21. [21]
    Is it worth investing in a high-efficiency power supply? - ExtremeTech
    Dec 12, 2012 · The good news is that power supplies with better 80 Plus ratings really do deliver what they claim -- there is a net reduction in total power consumption.
  22. [22]
    80 Plus Certification Explained: Why Efficiency Matters in Power ...
    Sep 19, 2024 · The 80 Plus certification is a standardized measure of power efficiency, designed to help consumers identify PSUs that waste less energy and run more ...Missing: program | Show results with:program
  23. [23]
    Dell 80 PLUS® Certifications - CLEAResult
    Dell offers 80 PLUS certified PSUs with Platinum, Titanium, Gold, Silver, and Bronze ratings, including models like AC1350EPF-00, L2800E-S0, and D180 ...
  24. [24]
    80 PLUS: Why you need titanium power supplies in your data center
    Aug 23, 2024 · In order to meet the 80 Plus certification, power supplies must be at least 80% efficient at 20%, 50%, and 100% of the rated load and achieve a ...
  25. [25]
    CLEAResult Announces 80 PLUS® Ruby: A New Data Center ...
    Mar 12, 2025 · 80 PLUS Ruby is the highest energy efficiency standard for data center PSUs, requiring 90%+ efficiency, with 96.5% at 50% load and 90% at 5% ...Missing: administration 2018 Ecos
  26. [26]
    [PDF] 80 PLUS® Ruby – The New Efficiency Target for Data Centers
    Compared to Titanium, Ruby increases the efficiency requirement at all power levels, with it increasing for 20% loads from 94% to 95%, and for 50% loads from 96 ...
  27. [27]
    None
    ### Summary of Efficiency Requirements for 80 Plus Certification
  28. [28]
    [PDF] Power factor - TECHNICAL ARTICLE
    P = V x A = VA, Equation 1; Apparent Power. The measurements must be made with “True RMS” meters. Unfortunately, this does not represent the real power.
  29. [29]
  30. [30]
    80 PLUS
    ### Summary of 80 Plus Certification Application Process
  31. [31]
    [PDF] 80 PLUS REVISED POWER SUPPLY TESTING/CERTIFICATION ...
    You are submitting your production, pre-production or reference design power supply models for 80. PLUS testing and certification to CLEAResult Consulting ...Missing: transferred | Show results with:transferred
  32. [32]
    None
    ### Summary of Testing and Validation Process for 80 Plus Certification (August 13, 2025, Version 2.5)
  33. [33]
    [PDF] 80 PLUS REVISED POWER SUPPLY TESTING/CERTIFICATION ...
    You are submitting your production, pre-production or reference design power supply models for 80. PLUS testing and certification to CLEAResult Consulting ...Missing: transferred Plug Solutions
  34. [34]
    80 PLUS "Ruby" Certification Announced For Data Center - Wccftech
    May 27, 2025 · CLEAResult has announced a new certification, called 80 PLUS Ruby, which aims to push the efficiency beyond the Titanium rating.<|separator|>
  35. [35]
    Antec explains: continuous power vs. peak power PSUs - PSU - News
    Jul 16, 2009 · Antec reckons "many brands on the market use misleading power efficiency labels or model names to confuse consumers". That might be the case ...<|separator|>
  36. [36]
    Threading Your Way Through the Labeling Requirements Under the ...
    Jul 2, 2014 · Federal labeling requirements for textile and wool products, enforced by the FTC, require that most of these products have a label listing the fiber content.
  37. [37]
    Power Supplies With Fake 80 Plus Badges - Hardware Secrets
    The product box features an 80 Plus logo that is clearly a fake, as you can see in Figure 1. KMEX PG-580: The manufacturer lists this model as having 80 Plus ...
  38. [38]
    Thermaltake Toughpower GF A3 750W ATX v3.1 PSU Review
    Aug 17, 2024 · Thermaltake Toughpower GF A3 750W ATX v3.1 PSU Review – Silent Platform Change, Messy Protection Features & Fake 80 Plus Badge. August 17, 2024 ...Missing: examples | Show results with:examples<|separator|>
  39. [39]
    80 Plus - Issues and Solutions - Cultists Network
    Apr 30, 2022 · The most obvious testing limit is the number of loads. 80 plus measures at 3-4 different loads and bases its conclusion off that. There isn't ...Missing: program criticisms
  40. [40]
    Corsair ditches 80 Plus for PSUs: here are the Cybenetics ratings it'll ...
    Aug 8, 2024 · Corsair is ditching 80 Plus ratings for its power supplies. Instead, it'll opt exclusively for an efficiency standard from Cybenetics.
  41. [41]
    ATX 3.0 explained: Why Intel just gave power supplies a ... - PC World
    Apr 18, 2022 · Intel isn't picking favorites but it's clear Cybenetic's program is stricter as it tests along a much larger range of loads versus 80 Plus's ...