Fact-checked by Grok 2 weeks ago

Bridge circuit

A bridge circuit is an electrical arrangement consisting of two parallel branches connected by a bridging network, typically used to measure unknown electrical parameters such as , , or by achieving a condition that nullifies the output voltage. This configuration, analogous to a balance scale, compares the outputs of two voltage dividers sharing a common source, enabling precise measurements with minimal interference from supply variations or nonlinearities. The most foundational form, the , was first demonstrated by Hunter Christie in 1833 for DC resistance measurement and later popularized by in 1843, who adapted it for practical use in determining unknown through ratio comparisons of four arms. Balance occurs when the ratio of resistances in one branch equals that in the other (e.g., R_1 / R_2 = R_3 / R_x), yielding zero differential voltage across the detector, independent of the excitation voltage. This null-balance principle provides high accuracy, often up to ±0.05% with sensitive detectors, making it essential for calibration labs and instrumentation. Beyond resistance, bridge circuits extend to AC applications, including the for capacitance-inductance measurements (developed by in 1891) and the for , each tailored to specific impedance parameters. They are integral in transducers like gauges (pioneered by in 1856) for sensing physical quantities such as , , and force, where small resistance changes produce measurable imbalances amplified for output. Additionally, bridge topologies underpin oscillators, such as the invented by William R. Hewlett in 1939, and switching circuits for across DC to GHz frequencies. Modern implementations often incorporate instrumentation amplifiers with high common-mode rejection (e.g., 120 dB) to enhance sensitivity and noise immunity in industrial and precision applications.

Introduction

Definition and Basic Concept

A bridge circuit is a fundamental electrical configuration designed for precise measurement of unknown electrical parameters, such as resistance in () applications or impedance in () setups, by employing a detection . This method involves comparing two circuit branches until equilibrium is reached, where the detector indicates zero output, enabling high-accuracy determinations without direct against absolute standards. Bridge s function as versatile tools in instrumentation, applicable to sensing physical quantities like or through associated transducers. In its basic form, a bridge circuit comprises four arms—typically labeled as resistors R1, R2, R3, and the unknown Rx—connected in a -shaped . An excitation is applied across one diagonal of the diamond (between the junctions of R1-Rx and R2-R3), while a detector, such as a for or a sensitive for , is placed across the opposite diagonal (between the junctions of R1-R2 and Rx-R3). This arrangement creates two networks, with the output derived from the potential difference between the midpoints, allowing for the isolation and quantification of the unknown component when balance is achieved. The primary purpose of a bridge circuit is to measure unknown electrical components with exceptional by adjusting the circuit until the detector registers zero current or voltage, signifying balanced conditions across the arms. This null-balance approach minimizes errors from source variations and detector sensitivities, achieving accuracies on the order of 0.1% or better in well-designed setups. Over time, bridge circuits have evolved from traditional analog null methods relying on manual adjustments to modern variants that integrate analog-to-digital converters, microprocessors, and amplifiers for automated balancing and improved stability in complex measurement environments.

Historical Development

The Wheatstone bridge, a foundational bridge circuit, was originally invented by British scientist Samuel Hunter Christie in 1833 as a method for measuring unknown electrical resistances through a balanced network of resistors. Christie described the configuration in a paper presented to the Royal Society, though it received limited attention initially. In 1843, , a professor at , independently refined and popularized the design, demonstrating its practical utility in a lecture that led to widespread adoption; the circuit became eponymously known as the despite Christie's prior invention. During the 19th-century Industrial Revolution, bridge circuits like the Wheatstone found early applications in precision electrical measurements and telegraphy systems, enabling accurate assessment of wire resistances over long distances to improve signal transmission reliability. A key milestone came in 1861 when William Thomson (Lord Kelvin) developed the Kelvin double bridge, an extension designed specifically for measuring very low resistances by compensating for lead wire effects, which was essential for applications in electrical engineering and metrology. The transition to alternating current (AC) bridges began in the late 19th century, with James Clerk Maxwell introducing an inductance-capacitance bridge in 1873 to measure unknown inductances using AC signals, marking an important evolution for handling reactive components. In 1891, Max Wien devised the Wien bridge, adapted for precise frequency measurements in AC circuits, further expanding bridge techniques to audio and impedance analysis. Post-World War II advancements in the mid-20th century integrated bridge circuits with emerging electronics, particularly through amplifiers in the 1960s, which amplified small signals from unbalanced bridges for enhanced in sensors and transducers. By the 1970s, the development of and bridges, featuring LED readouts and computerized balancing, revolutionized accuracy and speed, replacing manual detection in laboratory and industrial settings. These innovations, driven by and technologies, solidified bridge circuits as core elements in modern .

Principles of Operation

Balanced and Unbalanced Conditions

In a bridge circuit, the balanced condition is achieved when the potential difference across the detector is zero, indicating that the of impedances in the opposing satisfies Z_1 / Z_2 = Z_3 / Z_4. This equality ensures that the voltage dividers formed by the produce identical potentials at the detector points, regardless of the excitation source . Under unbalanced conditions, any mismatch in the arm impedances results in a non-zero voltage or current through the detector, with the magnitude proportional to the deviation in the unknown component's value. This output signal reflects the imbalance and serves as the basis for measuring changes in the circuit parameters. The provides a classic illustration of these states in applications. Achieving and maintaining can be influenced by several factors, including variations that alter component resistances—such as a 0.385% per °C change in wiring—leading to errors. Component tolerances introduce initial mismatches, potentially causing up to ±10% full-scale zero errors. In AC bridges, the excitation affects by modifying the reactive components of impedances, necessitating adjustments for and alignment. The null method exploits the balanced by iteratively adjusting one arm until the detector reading reaches zero, providing a precise independent of the excitation voltage level and minimizing errors from source fluctuations.

Sensitivity and Detection Methods

in bridge circuits is defined as the of the change in detector output (such as voltage or ) to a small change in the unknown component value, often normalized to the voltage, with this reaching its maximum near the balanced where arm resistances are equal. This measure quantifies the circuit's ability to detect minute imbalances, typically expressed in mV/V, with values ranging from 1 mV/V to 10 mV/V in standard configurations. Traditional detection methods rely on null indicators to identify balance. For DC bridges, a galvanometer serves as the detector, measuring the small current flowing through the unbalanced bridge arms with high precision, enabling detection of zero current to confirm balance. In setups requiring voltage measurement, a voltmeter is employed across the detector points, though its input impedance must be high to avoid loading the circuit. Modern detection techniques enhance sensitivity through amplification and noise rejection. Operational amplifiers (op-amps), often configured as instrumentation amplifiers, provide high gain for amplifying the low-level unbalanced output voltage, achieving resolutions suitable for precision applications. In noisy environments, particularly with excitation, lock-in amplifiers employ phase-sensitive detection to isolate the bridge signal from noise, improving the by orders of magnitude. Several factors influence the overall of bridge circuits. The ratios of the arm resistances play a critical role, as equal arm values near balance maximize the output response to perturbations in the unknown component. Source impedance affects performance by introducing bias currents that can unbalance the or cause voltage drops, necessitating low-impedance sources for optimal results. resolution, determined by the minimum detectable imbalance, can reach 0.1% accuracy in precision setups through careful component selection and . Despite these capabilities, limitations arise from practical implementations. Detector loading effects, such as those from finite op-amp , can alter the bridge balance and reduce measured sensitivity by introducing errors up to several percent. Additionally, stray capacitances in wiring or components couple noise and cause frequency-dependent imbalances, particularly in high-resolution AC bridges, requiring shielding and guarding techniques to mitigate.

Types of Bridge Circuits

DC Bridge Circuits

DC bridge circuits employ direct current (DC) excitation to measure resistances by arranging four resistors in a diamond-shaped network, with balance achieved when the voltage across the bridge's detector arm is zero, indicating equal potential division in the opposing branches. This configuration, often powered by a stable DC voltage source, relies on the null method where adjustments to one or more arms nullify the detector current, allowing precise resistance determination without direct current measurement through the unknown resistor. These circuits are particularly suitable for purely resistive networks, as DC excitation avoids phase shifts that arise from reactive elements like inductors or capacitors, ensuring accurate steady-state measurements focused solely on ohmic values. Common configurations feature series-parallel arm setups, exemplified by the , which enables straightforward DC balance for comparing resistances in the range of 5 Ω to 10 MΩ with accuracies exceeding 0.01%. Advantages of DC bridge circuits include their simplicity in and , utilizing basic components without the need for frequency-specific equipment, resulting in low cost and high stability for steady-state applications such as instrumentation where temperature compensation and signal augmentation enhance reliability. However, limitations arise when measuring components with or , as these introduce transient errors that prevent true DC balance, and in low-value resistance measurements, contact and lead resistances can significantly distort results unless mitigated by four-terminal techniques like the Kelvin configuration. A representative example is the use of DC bridges for basic resistance comparison in sensor applications, such as monitoring static strains via resistive elements, where the absence of frequency dependence ensures consistent performance independent of excitation variations.

AC Bridge Circuits

AC bridge circuits employ alternating current excitation, typically from sinusoidal voltage sources, to measure complex impedances involving resistance (R), inductance (L), and capacitance (C). This approach extends the utility of bridge configurations beyond purely resistive elements by accounting for both real and imaginary components of impedance, enabling precise determination of reactive parameters in components like inductors and capacitors. The balance condition in AC bridges requires that both the magnitude and phase of the voltages across the detector be nulled simultaneously, expressed in phasor form as \frac{Z_1}{Z_2} = \frac{Z_3}{Z_4}, where Z_1, Z_2, Z_3, Z_4 represent the complex impedances of the four arms. This equality ensures zero current through the detector, analogous to the resistive in bridges but incorporating phase alignment for reactive elements. Key advantages of AC bridges include their versatility in handling non-resistive components, allowing measurement of L and C alongside R, and the ability to tune the excitation for enhanced selectivity in distinguishing between similar impedances. Frequency adjustment can isolate specific reactive behaviors, improving accuracy in applications like component . Additionally, the bridge balance is independent of the source voltage magnitude, facilitating high-precision measurements with stable sinusoidal drives. Despite these benefits, AC bridges face challenges such as the skin effect, which increases effective resistance in inductors at higher frequencies by concentrating current near conductor surfaces, and dielectric losses in capacitors that introduce errors due to energy dissipation in insulating materials. Parasitic capacitances and inductances from wiring and environment can also disrupt balance, necessitating shielded enclosures and careful grounding techniques like the Wagner ground to minimize these effects. Typical operating frequencies for AC bridges range from the audio spectrum, often around 1 kHz for general-purpose measurements where detector sensitivity is optimal with or simple null indicators, to several MHz for high-frequency component testing using click-based detection or advanced . This tunability supports applications from low-speed setups to rapid, precise evaluations of RF elements.

Specific Bridge Configurations

Wheatstone Bridge

The Wheatstone bridge is a fundamental configuration in DC bridge circuits, specifically designed for precise measurement of medium-range electrical resistances. It consists of four resistors arranged in a diamond-shaped network, forming two parallel voltage dividers. The resistors are typically labeled as R1 and R2 in one arm, connected in series, and R3 and Rx (the unknown resistance) in the other arm, also in series. A DC voltage source, such as a battery, is applied across the top and bottom nodes (the junction between R1 and R3, and the junction between R2 and Rx), providing excitation to the circuit. A sensitive null detector, traditionally a galvanometer but often a high-impedance voltmeter in modern setups, is connected across the left and right nodes (the junction between R1 and R2, and the junction between R3 and Rx) to measure any differential voltage. The bridge operates on the principle of balance, where the is balanced when the indicates zero current or voltage, meaning the voltage drops across the two dividers are equal. This occurs when the ratio of the satisfies the condition: \frac{R_1}{R_2} = \frac{R_3}{R_x} Solving for the unknown gives R_x = R_3 \cdot \frac{R_2}{R_1}. In , R1 and R2 are fixed known forming a ratio arm (often R1 = R2 for simplicity, making the ratio 1:1), while R3 is a variable , such as a decade box, adjusted during measurement. To measure Rx, the operator applies the voltage, monitors the , and incrementally adjusts R3 until deflection is achieved, at which point Rx is calculated directly from the known values without needing to measure currents or voltages during the balanced state. This method provides high precision because it relies on the of the detector rather than absolute measurements. The accuracy of the Wheatstone bridge can reach up to 0.01% when using precision decade boxes for R1, R2, and R3, with tolerances better than 0.01% and stable temperature coefficients. However, several error sources can limit performance, including lead , which adds unintended in series with Rx and introduces systematic errors, particularly for values below 1 Ω where lead drops can exceed 0.1% of the total. Other errors arise from thermal effects on resistors, loading if not high-impedance, and at connections, though these are minimized by using four-wire techniques or guarding in advanced setups. Although the bridge is named after Sir , who popularized it through a public demonstration and paper in 1843, the original circuit was invented by Hunter Christie in 1833 as a method for measuring unknown resistances by balancing currents in a network of wires. Wheatstone acknowledged Christie's priority in his work, but the name persisted due to Wheatstone's improvements, such as incorporating a rheostat for finer adjustments.

Kelvin Double Bridge

The Kelvin double bridge is an advanced configuration of the bridge circuit specifically engineered for accurate of very low resistances, typically in the range below 1 , where conventional methods like the suffer from significant errors due to lead and contact resistances. This setup employs a approach for both the unknown resistance and the standard, ensuring that the potential leads carry negligible current and thus isolating the from extraneous resistances. In terms of configuration, the Kelvin double bridge features two interconnected Wheatstone bridges: a primary bridge with ratio arms R_1 and R_2, and an auxiliary bridge with smaller ratio arms r_1 and r_2, linked by a low-impedance network (often denoted as r_l) that connects the midpoints. The unknown low R_x and a standard R_s (or R_3 in some notations) are each connected via separate pairs of current-carrying and voltage-sensing terminals, totaling eight terminals overall to prevent lead . A or null detector is placed across the bridge junction to indicate . The balance condition for the Kelvin double bridge is achieved when the galvanometer current is zero, leading to the equation: R_x = \frac{R_3}{R_1} R_2 + \text{corrections for lead resistances } r_1, r_2 where the corrections account for unequal ratios between the main and auxiliary arms, typically expressed as small terms involving r_l (the linking resistance) to adjust for any residual lead effects; in the ideal case where \frac{r_1}{r_2} = \frac{R_1}{R_2}, the lead resistances are fully eliminated, simplifying to R_x = \frac{R_3}{R_1} R_2. This condition ensures high precision, with accuracies often reaching ±0.05% for resistances down to 0.00001 ohms. The measurement procedure requires two sequential balance adjustments to null the detector. First, the auxiliary bridge is balanced by varying r_1 and r_2 to match the ratio of the main arms R_1 and R_2, minimizing the impact of lead resistances r_1 and r_2. Second, the main bridge is balanced by adjusting R_2 or R_3 until the galvanometer shows no deflection, at which point R_x is directly computed from the known arm values. A stable DC current source is used throughout to maintain consistent voltage drops. In applications, the Kelvin double bridge is widely employed in and laboratories for verifying shunt resistors used in ammeters and low-value resistors essential for electrical . Its ability to handle resistances as low as milliohms with minimal error makes it indispensable for high-impact tasks like calibrating current shunts in national measurement institutes.

Maxwell Bridge

The is an bridge circuit designed for the precise measurement of unknown and its associated series , particularly suitable for medium-Q inductors. It consists of three resistors and one arranged in a configuration that compensates for the inductive without requiring a . Specifically, the unknown L_x in series with R_x forms one arm of the bridge, while the adjacent arm contains R_2, the opposite arm has R_3, and the remaining arm features the C_4 in with R_4. This setup allows for by adjusting the and one , leveraging the opposition between the inductive and capacitive arms to achieve null detection. At balance, the bridge satisfies the condition where the product of opposite arm impedances are equal, resulting in magnitude-only equations independent of and \omega. The is given by L_x = R_2 R_3 C_4 and the series by R_x = \frac{R_2 R_3}{R_4}. The balance occurs automatically due to the capacitive arm counteracting the inductive phase shift, eliminating the need for frequency-specific adjustments. This configuration ensures that both and conditions are met simultaneously through simple variation of C_4 and R_4. Key advantages of the Maxwell bridge include its simplicity in adjustment using a readily available , which avoids the complexities and cost of variable inductors, and its independence from source frequency, making it robust against variations in the AC supply. It is particularly effective for inductors with quality factors Q between 1 and 10, where Q = \omega L_x / R_x, as the balance equations remain stable without residual inductance errors from mutual coupling. However, it is less suitable for very low-Q or high-Q coils due to sensitivity limitations in those ranges. The bridge typically operates in the audio frequency range of 1 to 10 kHz, ideal for measuring medium s from millihenries to henries with high accuracy, as higher frequencies can introduce parasitic effects while lower ones reduce . A variation known as the inductance comparison bridge adapts the configuration for comparing an unknown to a standard one, often used in calibrations involving mutual effects by incorporating a reference in place of the capacitive arm to directly ratio s while minimizing lead and ground errors.

Wien Bridge

The is an AC bridge circuit invented by Max Wien in 1891 and originally developed for precision measurement of , particularly in the context of dielectric testing to determine and conductance for calculating loss angles in materials like electric cables. This configuration extends the principle to handle frequency-dependent impedances, enabling accurate assessment of capacitive components under sinusoidal excitation. The circuit features a series RC arm (typically resistor R_1 in series with known capacitor C_1) and an adjacent parallel RC arm (resistor R_2 in parallel with unknown capacitor C_x), completed by two ratio arms consisting of resistors R_3 and R_4. At balance, the voltage across the detector is zero, allowing the unknown capacitance C_x or the operating frequency to be determined by adjusting the bridge elements while applying an AC source. The balance conditions derive from equating the impedances of opposing arms, yielding two independent equations: one for the resistive components and one for the reactive components. For capacitance measurement, the unknown C_x satisfies C_x = C_1 \cdot \frac{R_3}{R_4}, assuming specific in the RC arms. Alternatively, for frequency determination with known components, the balance occurs at f = \frac{1}{2\pi \sqrt{R_1 R_2 C_1 C_x}}. In its standard form, the Wien bridge serves as a null detector for precise component measurement by achieving balance through adjustments. A variant employs positive feedback by integrating the bridge network into an amplifier circuit with a gain of approximately 3, transforming it into an oscillator that sustains sinusoidal output at the balance frequency. The Wien bridge exhibits high sensitivity to changes in , making it suitable for detecting small variations in properties, and operates effectively in the range of approximately 100 Hz to 100 kHz.

Applications

Electrical Component

Bridge circuits are fundamental tools for precisely measuring electrical components such as resistances, capacitances, and inductances by achieving a condition, where the voltage across a detector is zero, indicating equality between arms. This minimizes errors from detector sensitivity and supply variations, enabling high accuracy in and settings. Measurements typically involve comparing the unknown component against known standards, with achieved through adjustable resistors, capacitors, or inductors. For resistance measurement, the Wheatstone bridge serves as the standard configuration for general-purpose applications, determining unknown resistances from a few ohms to megaohms by balancing DC ratios in its arms. It provides precise results when lead resistances are negligible, commonly used in educational labs and basic instrumentation for verifying resistor values. For low-value resistances, such as milliohms in cables or shunts, the Kelvin double bridge is employed to eliminate errors from contact and lead resistances through its four-terminal configuration and linked ratio arms. This setup ensures accuracy in conductivity samples and precision components, where standard Wheatstone methods would introduce significant offsets. Capacitance measurements utilize AC bridge circuits to account for reactive impedances. The De Sauty bridge, consisting of two resistors and two capacitors, compares unknown against a standard by balancing at a specific , ideal for non-lossy . For capacitors with losses, such as those in cables or insulators, the Schering bridge measures both and the loss angle () using a configuration of resistors and capacitors that remains -independent for enhanced precision. This bridge supports high-voltage applications, quantifying phase differences to assess material quality. Inductance evaluation relies on AC bridges tailored to coil quality factors. The Maxwell bridge measures self-inductance in low-Q inductors (Q factor 1-10) by balancing resistance and inductance arms against a standard capacitor, suitable for audio-frequency coils in transformers. For high-Q inductors (Q > 10), the Hay bridge provides accurate determination of self- and mutual inductance, incorporating frequency-dependent balance conditions to handle reactive dominance in RF components. To achieve high precision, bridge circuits are calibrated using traceable standard components from national laboratories, with error analysis focusing on component tolerances and environmental factors like . For instance, tolerances of 0.05% enable overall accuracies approaching that level in well-controlled setups, though lead resistances and leakage currents can introduce errors up to several percent in high-resistance cases without guards. techniques include the comparison , where the unknown is balanced against a , and the , which alternates between standard and unknown for differential balancing to reduce systematic errors and improve precision in challenging measurements. The approach is preferred for its ability to nullify bridge imbalances more accurately, especially in circuits operating from 40 Hz to 125 kHz.

Sensor and Instrumentation Uses

Bridge circuits, particularly the Wheatstone configuration, are integral to applications where they convert mechanical, thermal, or physical changes into measurable electrical signals through resistance variations. In these setups, the bridge's unbalance produces a voltage proportional to the sensed parameter, enabling precise detection in systems. Strain gauge bridges commonly employ a full with four active gauges to measure deformation, providing compensation for temperature fluctuations and bending effects by arranging gauges such that opposing arms experience similar environmental influences. This configuration enhances sensitivity compared to half-bridge setups, as all four elements contribute to the output signal, allowing detection of microstrain levels in structural . For instance, in load cells, the full-bridge arrangement stabilizes output against thermal variations, ensuring reliable force measurements. In transducers, bridge circuits detect unbalance to output signals from various physical phenomena. Pressure transducers often use piezoresistive elements in a Wheatstone bridge, where applied pressure alters resistor values to produce a voltage change; full-bridge designs in MEMS sensors automatically compensate for temperature, achieving high accuracy in cardiovascular or industrial applications. Temperature transducers incorporate resistance temperature detectors (RTDs) in a Wheatstone bridge, where the RTD's resistance shift with temperature unbalances the circuit for precise readout, typically using a voltage divider variant for linearization. Displacement sensors leverage bridge-based strain gauges or inductive elements, correlating position changes to resistance or impedance variations for non-contact measurements in automation systems. Instrumentation amplifiers are frequently integrated with bridge circuits to condition low-level differential signals from sensors, amplifying the output while rejecting common-mode noise before feeding into analog-to-digital converters in devices like digital multimeters. These amplifiers provide high input impedance and low offset, ensuring the bridge's ratiometric nature preserves measurement integrity across varying supply voltages. Modern applications include automotive anti-lock braking systems (), where magneto-resistive bridges in wheel speed sensors detect rotational variations to prevent skidding, doubling signal output and reducing drift for reliable performance. In medical instrumentation, bridge circuits measure bioimpedance for applications like electrocardiograms (ECGs) and monitoring, using four-electrode setups to assess impedance waveforms at sites such as the , aiding in non-invasive vital sign detection. The advantages of bridge circuits in sensors stem from their ratiometric measurement principle, which inherently cancels supply voltage fluctuations and common-mode noise, yielding high —such as microstrain detection—without needing precise sources. This approach supports noise-immune, high-accuracy systems in demanding environments.

Mathematical Analysis

General Bridge Balance Equation

In bridge circuits, the balance condition occurs when the potential difference across the detector is zero, resulting in no current flow through it. This universal principle applies to both DC and AC configurations, serving as the foundation for measuring unknown electrical parameters by achieving null detection. The derivation of this condition typically involves applying Kirchhoff's voltage law (KVL) and current law (KCL) to the circuit nodes and loops, assuming the detector has infinite impedance or zero current, which equates the voltages at the bridge's output junctions. For DC bridge circuits composed of resistive arms, the balance equation simplifies to the ratio of resistances in parallel branches being equal: \frac{R_1}{R_2} = \frac{R_3}{R_x}, where R_1 and R_2 form one , and R_3 and R_x (the unknown resistance) form the other. This relation arises from setting the voltages equal via KCL at the detector points, ensuring current conservation without flow across the bridge diagonal. The condition holds regardless of the source voltage, as the ratios are scale-invariant. In AC bridge circuits, where arms may include inductors, capacitors, or resistors, the balance condition generalizes to impedances using complex notation: \frac{Z_1}{Z_2} = \frac{Z_3}{Z_4} Here, each impedance is Z_i = R_i + j \left( \omega L_i - \frac{1}{\omega C_i} \right), with \omega as the , L_i the , C_i the , and j the . The derivation mirrors the DC case but employs analysis: Kirchhoff's laws are applied in the to node voltages, setting the phasor current through the detector to zero, which requires both and equality in the ratios. This ensures the real and imaginary components of the voltage difference nullify simultaneously. Like the DC case, the balance is independent of the AC source , depending solely on the impedance ratios at the operating .

Current and Voltage Derivations

In (DC) bridge circuits, such as the , the output voltage across the detector for an unbalanced condition is derived from voltage division in the two arms. Assuming a standard configuration with excitation voltage V_s, resistors R_1 and R_2 in one arm, and R_3 and unknown R_x in the other, the voltage at the junction of R_1 and R_2 is V_s \cdot \frac{R_2}{R_1 + R_2}, while at the junction of R_3 and R_x it is V_s \cdot \frac{R_x}{R_3 + R_x}. The differential output voltage is thus V_\text{out} = V_s \left[ \frac{R_2}{R_1 + R_2} - \frac{R_x}{R_3 + R_x} \right]. To analyze the effect of a detector with finite impedance, the Thévenin equivalent circuit is applied to the bridge output terminals. The Thévenin voltage V_\text{th} is the open-circuit output voltage V_\text{out} given above. The Thévenin resistance R_\text{th} is found by deactivating the source (shorting V_s) and computing the equivalent resistance across the detector terminals, yielding the series combination of the parallel impedances of the two voltage dividers: R_\text{th} = \frac{R_1 R_2}{R_1 + R_2} + \frac{R_3 R_x}{R_3 + R_x}. With a galvanometer of resistance R_g connected as the detector, the current through it is then I_g = \frac{V_\text{th}}{R_\text{th} + R_g}. This follows directly from the Thévenin equivalent, where the galvanometer loads the simplified circuit. For alternating current (AC) bridges, the analysis extends the DC case by replacing resistances with complex impedances Z_1, Z_2, Z_3, Z_x. The output voltage becomes a phasor given by \mathbf{V}_\text{out} = V_s \left[ \frac{Z_2}{Z_1 + Z_2} - \frac{Z_x}{Z_3 + Z_x} \right], where reactive elements contribute imaginary components (Z_L = j \omega L, Z_C = 1/(j \omega C)). The Thévenin equivalent follows analogously, with \mathbf{V}_\text{th} as the open-circuit phasor and Z_\text{th} computed similarly using deactivated sources. The sensitivity of the bridge, defined as the rate of change of output voltage with respect to the unknown resistance at balance (d V_\text{out} / d R_x \big|_{\text{balance}}), quantifies detection capability. For the quarter-bridge case (one variable arm, others equal to R), near balance with small \Delta R = R_x - R, \frac{d V_\text{out}}{d (\Delta R)} \approx \frac{V_s}{4 R}, derived by differentiating V_\text{out} \approx V_s \cdot \frac{\Delta R}{4 R} for \Delta R \ll R. This sensitivity is maximum when all arms are equal, as unequal ratios reduce the slope; for example, in a general configuration, it scales with V_s / (R_1 + R_2)^2 times arm ratios, peaking at equality.

References

  1. [1]
    What are Bridge Circuits: the basics - Electronics Notes
    The bridge was originally developed as a way of measuring various electrical parameters. Although they may seem rather archaic in some ways, this could not be ...
  2. [2]
    Bridge Circuits | DC Metering Circuits | Electronics Textbook
    Unlike the “potentiometer” circuit used to simply measure an unknown voltage, bridge circuits can be used to measure all kinds of electrical values, not the ...Missing: history | Show results with:history
  3. [3]
    AN-43: Bridge Circuits - Analog Devices
    Bridge circuits are among the most elemental and powerful electrical tools. They are found in measurement, switching, oscillator and transducer circuits.
  4. [4]
    [PDF] Department of Electronic Engineering ELE2EMI ... - Rose-Hulman
    Definition: Bridges are electrical circuits for performing null measurements on resistances in DC (direct current) and general impedances in AC (alternating ...
  5. [5]
    Basics of Bridge Circuits | Basic Direct Current (DC) Theory | Textbook
    A bridge circuit is basically a pair of voltage dividers where the circuit output is taken as the difference in potential between the two dividers.
  6. [6]
    [PDF] Bridge Circuits - "Modular Electronics Learning (ModEL) project"
    Sep 17, 2025 · As electrical meter technology improved, bridge circuits still remained a viable way to measure resistance with high accuracy. Other types ...
  7. [7]
    Wheatstone Bridge – 1843 - Magnet Academy - National MagLab
    A scientist and mathematician, Samuel Hunter Christie, developed the circuit to measure unknown electrical resistances and first described it in 1833.
  8. [8]
    Sir Charles Wheatstone: Father of the Wheatstone Bridge and British ...
    English physicist and inventor Charles Wheatstone is best known for his work on the Wheatstone bridge and mass adoption of the telegraph.<|control11|><|separator|>
  9. [9]
    (PDF) Maxwell Bridge: Past Present - Academia.edu
    Dec 18, 2020 · Maxwell Bridge, introduced by James Clerk Maxwell in 1873, measures inductance using AC techniques. The bridge is a modification of the ...
  10. [10]
    StudentZone—Analyzing and Building the Wien Bridge Oscillator ...
    The Wien bridge was developed by Max Wien in 1891 as an extension of the Wheatstone bridge. ... Figure 3. Wien bridge frequency ...Missing: invention | Show results with:invention
  11. [11]
    History - Wayne Kerr Electronics
    During this decade, Wayne Kerr was one of the first companies to introduce automatic bridges (LCR meters) with LED displays. In the past, bridges had required ...Missing: digital | Show results with:digital<|control11|><|separator|>
  12. [12]
    [PDF] SECTION 2 BRIDGE CIRCUITS - Analog Devices
    Regardless of its value, the stability of the excitation voltage or current directly affects the overall accuracy of the bridge output.
  13. [13]
    Bridges I Have Crossed
    current Wheatstone bridge, now written as Z1 Z4 = Z2 Z3 . There were always two balance conditions: one for the real part of the equation and one for the ...
  14. [14]
    [PDF] A Basic Guide to Bridge Measurements (Rev. A) - Texas Instruments
    A Wheatstone bridge is a circuit used to measure a change in resistance among a set of resistive elements. The circuit has two parallel resistive branches that ...
  15. [15]
    [PDF] Bridge Measurement Systems - Texas Instruments
    Bridge measurement systems are for data acquisition of bridge sensors, like load cells, and can be single-point, two-point, or four-point configurations.
  16. [16]
    [PDF] Principles of lock-in detection and the state of the art
    Nov 21, 2016 · (b) Digital lock-in amplifier: the signal is digitized and then multiplied with the reference signal and filtered. 100, because the noise ...
  17. [17]
    [PDF] IEEE Standard Test Code for Resistance Measurement
    Under most circumstances, a bridge circuit is the most accurate method of measuring resistance. The following subsections describe some of the bridge circuits ...
  18. [18]
    Lessons In Electric Circuits -- Volume II (AC) - Chapter 12 - Ibiblio
    AC bridge circuits work on the same basic principle as DC bridge circuits: that a balanced ratio of impedances (rather than resistances) will result in a ...
  19. [19]
    None
    ### Wheatstone Bridge in DC Operation for Strain Gauges or Resistance
  20. [20]
    AC Bridge Circuits | AC Metering Circuits | Electronics Textbook
    AC bridge circuits often have more than one adjustment, since both impedance magnitude and phase angle must be properly matched to balance. Some impedance ...
  21. [21]
    [PDF] A.C. Bridges
    Eq. (3) is the balance condition for a.c bridges. This indicates that when the ratio of impedances in two adjacent arms of bridge is equal to the ratio of ...
  22. [22]
    AC Bridges: Know Definition, Working, Types, Circuit & Applications
    It works on the principle that the balance ratio of the impedances will give the balance condition to the circuit which is determined by the null detector.
  23. [23]
    What is a Bridge Circuit? - Keysight Oscilloscope Glossary
    When a bridge circuit is balanced, the ratio of resistances (or impedances) in one leg equals the ratio in the other leg. This condition results in no current ...
  24. [24]
    An undergraduate physics experiment to measure the frequency ...
    Oct 1, 2023 · One of the most accurate ways to measure the impedance of an electrical component is to place it in a bridge that is then balanced.
  25. [25]
    [PDF] A Shielded Bridge for Inductive Impedance Measure - vtda.org
    The bridge is completely shielded so as to eliminate, to a high degree, errors due to parasitic capacitance currents. ... 6-Bridge circuit with stray admittances.
  26. [26]
    [PDF] EXPERIMENT 5: DC AND AC BRIDGE CIRCUITS 10/7/03 This ...
    Oct 7, 2003 · This experiment demonstrates the use of the Wheatstone Bridge for precise resistance measurements and the use of error propagation to determine ...
  27. [27]
    [PDF] Strain Gauge Measurement – A Tutorial
    lead resistance adds 2 Ω of resistance to that arm of the bridge. Besides adding an offset error, the lead resistance also desensitizes the output of the bridge ...<|control11|><|separator|>
  28. [28]
    To study the Kelvin Double Bridge for Low resistance measurement
    Under balance conditions there is no current through the galvanometer which means that the voltage drop between a and b, Eab is equal to voltage drops Eamd ...Missing: configuration | Show results with:configuration
  29. [29]
    [PDF] Four Wire Measurement - Experimentation Lab
    Used for precision dc resistance measurements, the Kelvin bridge configuration (Fig. 8) is the best known four-terminal technique. The Kelvin bridge has a main ...
  30. [30]
    [PDF] NIST Measurement Service for DC Standard Resistors
    This bridge, designed in 1918, was a combination Wheatstone bridge and Kelvin double bridge with ratios of 1-to-1 or 10-to-1 having an adjustment range of 5000 ...
  31. [31]
    [PDF] Calibration of inductance standards in the Maxwell-Wien bridge circuit
    (February 28, 1961). This paper discusses the errors from residuals in the Maxwell-vVien bridge a,nd the effect of these on the measurement of inductors in ...Missing: invention | Show results with:invention<|control11|><|separator|>
  32. [32]
    Maxwell Bridge - an overview | ScienceDirect Topics
    They provide an accurate method of measuring resistance, inductance, and capacitance values, and enable the detection of very small changes in these quantities ...
  33. [33]
    [PDF] The Use of the Wien Bridge for the Measurement of the ... - Zenodo
    : Having made many measurements of dielectric losses with the Wien. Bridge and the Schering Bridge, I was surprised to find that ilk. Rosen had used the Wen ...
  34. [34]
    [PDF] Lecture 4: Sensor interface circuits - Engineering People Site
    n Measurement of capacitance n Measurement of impedance. Page 2. Intelligent ... n Wien bridge g Inductance measurement n Hay bridge n Owen bridge. C1. R1.
  35. [35]
    Wien Bridge Oscillator Tutorial and Theory
    The Wien Bridge Oscillator is a two-stage RC coupled amplifier circuit that has good stability at its resonant frequency, low distortion and is very easy to ...Missing: arms | Show results with:arms
  36. [36]
    What is Wien's Bridge? - Explanation & Circuit Diagram
    The Wien's bridge use in AC circuits for determining the value of unknown frequency. The bridge measures the frequencies from 100Hz to 100kHz.
  37. [37]
    (PDF) 2 Bridge Measurement - Academia.edu
    This paper discusses the operational principles and advantages of bridge measurement circuits used for precision measurements of electrical components.<|separator|>
  38. [38]
    [PDF] Precision Resistors and Their Measurement
    It has an advantage over the ordinary. Wheatstone bridge in that the resistance in terms of which the unknown is measured may be that of an actual standard ...
  39. [39]
    [PDF] E12b: Determining Resistance & Resistivity with a Wheatstone Bridge
    Aug 18, 2014 · The Wheatstone Bridge is a circuit that is designed to make very precise measurements of the resistance of different materials.
  40. [40]
    [PDF] precision resistors and their measurement
    terms of a resistanceratio by means of the Kelvin double-bridge. The circuit of the Kelvin double bridge is shown in figure 16, where X and S denote the.
  41. [41]
    [PDF] An ultra low frequency bridge for dielectric measurements
    Dielectric measurements with this apparatus are carried out bv the direct method. rrhe substitution method is preferable to the direct method if precise.
  42. [42]
    Resistive Bridge Basics: Part One | Analog Devices
    Dec 22, 2004 · Bridge circuits are a time-honored way to make accurate measurement of resistance and other analog values. This article covers the basics of ...
  43. [43]
  44. [44]
    Strain Bridge - an overview | ScienceDirect Topics
    These strain gauges are typically used as elements in a Wheatstone bridge circuit, which is used to make the measurement.
  45. [45]
    Enhancing TreeMMoSys with a high-precision strain gauge to ...
    Moreover, the full Wheatstone bridge configuration has a higher sensitivity than other Wheatstone bridge configurations [34]. We applied a TSS sampling ...
  46. [46]
    Design and Shape Optimization of Strain Gauge Load Cell for Axial ...
    The type of bridge configuration with a strain gauge in a Wheatstone bridge depends on how many active component legs are present [39].
  47. [47]
    Soft, full Wheatstone bridge 3D pressure sensors for cardiovascular ...
    Jan 29, 2024 · A three-dimensional (3D) piezoresistive sensor that automatically compensates for temperature variations by use of a Wheatstone bridge architecture and an ...
  48. [48]
    Bridge Configurations for Pressure Sensors
    Jan 30, 2023 · This article describes bridge configurations of different pressure sensors, when each can and cannot be used, and the pros and cons of each.
  49. [49]
  50. [50]
    An Introduction to RTD Sensor Signal Conditioning Circuits
    Oct 30, 2022 · Learn about the basics of different signal conditioning circuits for RTD applications, including a voltage divider, Wheatstone bridge circuit, and delta-sigma ...
  51. [51]
    RTD Temperature Sensors: Types, Applications, Differences
    May 15, 2023 · A Wheatstone bridge circuit usually measures the RTD's resistance, which balances the unknown resistance with a known resistance. The Wheatstone ...
  52. [52]
  53. [53]
    [PDF] Bridge Sensor Solution (Rev. A) - Texas Instruments
    Instrumentation amplifiers (in amp or INA) are a common way of translating low-level sensor outputs to high- level signals that can drive an ...
  54. [54]
    Bridge-Type Sensor Measurements are Enhanced by Autozeroed ...
    This article discusses a versatile IC instrumentation amplifier with very low drift and many useful features, and its role in bridge instrumentation.
  55. [55]
    An Introduction to Wheatstone Bridge Circuits and Differential ...
    Sep 15, 2020 · The working principle of the bridge is the use of four resistors typically represented by a diamond shape. In Altium, we need to present this as ...
  56. [56]
    Diagnosis of Faulty ABS Systems - Brake & Front End
    Jun 1, 2005 · Inside the sensor is a small integrated circuit containing a magneto-resistive bridge (See Figure 4). The magneto-resistive bridge changes ...
  57. [57]
    Eye on Electronics | ABS Sensors | MOTOR Magazine
    There are a variety of advantages to using the Wheatstone bridge configuration. The bridge reduces temperature drift. It also doubles the signal output to ...
  58. [58]
    An Accurate Bioimpedance Measurement System for Blood ... - NIH
    To measure the impedance waveform at the wrist, four electrodes are placed above the radial artery in a vertical direction (Figure 2). This structure has shown ...
  59. [59]
    A Novel Measurement System to Simultaneously Obtain Three ...
    Mar 20, 2025 · Some examples of this type of devices are commonly used today to measure electrocardiograms (ECGs) or bioelectrical impedance analysis (BIAs) in ...
  60. [60]
  61. [61]
    Ratiometricity, digital signal correction enable high-res, low-...
    Dec 1, 2011 · A ratiometric topology allows for nearly noise-free applications that are essentially immune to supply voltage interference and have an effective signal ...<|control11|><|separator|>
  62. [62]
    [PDF] E12c: Kirchhoff's Rules and Bridge Circuits
    Oct 10, 2018 · The basic design of the bridge circuit is so effective that it has been included in numerous types of precision measurement components, such as ...
  63. [63]
    Derive the equation of the balanced state in a Wheatstone bridge ...
    Dec 19, 2022 · Next, we apply Kirchhoff's loop rule to closed loops ADBA and CBDC. The first loop gives. –I1R1 + 0 + I2R1 = 0 ..
  64. [64]
  65. [65]
    Wheatstone Bridge Circuit
    On this page we discuss an the Wheatstone bridge circuit which is an important circuit that is used in wind tunnel instrumentation.Missing: definition | Show results with:definition
  66. [66]
    [PDF] Homework #1 Solution 1. Standard Wheatstone Bridge
    Standard Wheatstone Bridge. The sign of the output voltage of a bridge ... For the Thevenin resistance, we have short out the voltage source and obtain.
  67. [67]
    None
    ### Summary of AC Bridge Circuit Analysis Using Complex Impedances