Hygrometer

A hygrometer is an instrument used to measure the amount of , or , in the air. The first known hygrometer in Western civilization was described around 1450 by the mathematician Nicholas Cusa, who devised a device to gauge by weighing changes in the moisture absorbed by materials like or . Hygrometers operate on diverse principles depending on their type, with mechanical variants such as the hair hygrometer relying on the expansion and contraction of organic fibers like human or animal hair in response to moisture levels, while psychrometers determine relative humidity through the temperature difference between dry and wet bulb thermometers via evaporative cooling. Electronic hygrometers, including capacitive models, detect humidity by measuring changes in the dielectric constant of a material exposed to air, and resistive types monitor variations in electrical resistance of hygroscopic substances. Gravimetric hygrometers serve as primary standards by physically separating and weighing water vapor from a gas sample to compute humidity precisely. These instruments are essential in fields like for , in national parks, and calibration services for industrial applications such as (HVAC) systems. Modern advancements, including chilled-mirror dew-point hygrometers and hybrid humidity generators, enable high-accuracy measurements across wide ranges, supporting research in and standards development.

Fundamentals

Definition and Principles

A hygrometer is a device that measures the amount of present in the air or other gases, typically quantifying humidity in terms of relative humidity (RH), absolute humidity, or temperature. These measurements are essential for assessing the moisture content in gaseous environments, where exists as an invisible gas mixed with dry air or other components. The fundamental principles of hygrometry rely on the physics of in gases, particularly the concept of as described by of partial pressures. arises from the of water into the gas phase, where the rate of evaporation depends on the difference between the saturation and the actual partial pressure of . Absolute is defined as the mass of per unit volume of the gas (often in grams per cubic meter), representing the total amount of present regardless of . In contrast, relative expresses the moisture level as a percentage of the maximum possible at a given , calculated as the ratio of the actual partial pressure of (e) to the saturation (e_s) at that : \text{RH} = \left( \frac{e}{e_s} \right) \times 100\%. The is the at which the current content would saturate the air, meaning e = e_s at that lower . This key equation for relative humidity derives from the applied to treated as an . The states PV = nRT, or in terms of density, the of e = \frac{\rho_v RT}{M_w}, where \rho_v is the humidity (mass density of ), R is the , T is the , and M_w is the of . For conditions, e_s = \frac{\rho_{vs} RT}{M_w}, where \rho_{vs} is the . The ratio simplifies to \text{RH} = \frac{\rho_v}{\rho_{vs}} \times 100\% = \frac{e}{e_s} \times 100\%, as the temperature-dependent factors RT / M_w cancel out. vapor pressure e_s itself emerges from the between and : at , the rate of molecules escaping the liquid surface equals the rate returning from the vapor phase, a balance influenced by via the Clausius-Clapeyron relation, though approximated here through the behavior for dilute vapors. proceeds when e < e_s, driving net moisture transfer into the gas until is achieved, while exceeding e_s leads to . The term "hygrometer" originates from the Greek "hygros," meaning wet or moist, combined with "metron," meaning measure, and was coined in the 1660s from the French "hygromètre." This nomenclature reflects the instrument's purpose in quantifying atmospheric moisture through these physical principles.

Measured Parameters

Hygrometers measure several key parameters that quantify atmospheric moisture, each providing distinct insights into humidity levels. The primary parameters include relative humidity (RH), expressed as a percentage (%), which represents the ratio of the current vapor pressure to the saturation vapor pressure at a given temperature. Dew point temperature (Td), measured in degrees Celsius (°C), is the temperature at which air becomes saturated with water vapor, leading to condensation. Absolute humidity indicates the mass of water vapor per unit volume of air, typically in grams per cubic meter (g/m³), though the SI unit is kilograms per cubic meter (kg/m³). Specific humidity, a dimensionless ratio (kg/kg), measures the mass of water vapor per unit mass of moist air. The mixing ratio, also dimensionless (often g/kg in practice), quantifies the mass of water vapor per unit mass of dry air and is closely related to specific humidity, differing only slightly since specific humidity accounts for the total air mass including vapor. Conversions between these parameters rely on established formulas that account for and dependencies. A common approximation for from (T in °C) and RH is Td \approx T - \frac{100 - RH}{5}, useful for quick estimates in . More precise calculations use the Magnus formula for saturation (e_s) over liquid water: e_s = 6.112 \times \exp\left( \frac{17.67 \times T}{T + 243.5} \right) where e_s is in hectopascals (hPa) and T is in °C; the actual e is then e = \frac{RH}{100} \times e_s(T), and Td solves e = e_s(Td). can be derived from using the for , while specific humidity q and mixing ratio r interrelate as q = \frac{r}{1 + r}, with both convertible from via saturation pressures. In SI units, is percentage-based (dimensionless), Td and related temperatures in (K) or °C, absolute humidity in kg/m³, and specific humidity or mixing ratio in kg/kg. Relative humidity is the most commonly reported parameter in practical applications due to its intuitive scale from 0% to 100%, facilitating everyday communication and comfort assessments. However, provides greater precision, especially at low humidity levels, as it directly reflects absolute moisture content independent of air temperature, avoiding the variability in RH that occurs with temperature fluctuations. For sub-zero conditions, the frost point replaces the , defined as the temperature at which water vapor deposits directly as ice at constant pressure, essential for accurate measurements in cold environments. Psychrometers derive these parameters from wet-bulb depression, linking temperature differences to .

Historical Development

Ancient Hygrometers

The earliest documented attempts at humidity detection in ancient China date to the Western Han dynasty around 120 BCE, as described in the text Huai-Nan-Zi, where a method involved suspending a feather and a piece of charcoal in the air to compare their relative weights as an indicator of atmospheric moisture—the charcoal absorbed humidity and became heavier in damp conditions, while the feather remained lighter. In ancient Greece, around the 4th century BCE, philosophers such as Aristotle and his successor Theophrastus explored concepts of atmospheric moisture in works like Aristotle's Meteorology and Theophrastus's On Weather Signs, relying on qualitative observations of natural phenomena, such as the behavior of hygroscopic materials like straw or papyrus that altered in length or flexibility with humidity changes, to inform weather predictions without formalized devices. These early approaches highlighted empirical recognition of humidity's effects on organic materials but lacked precision or standardization. By the late , inventors advanced rudimentary hygroscopes—non-quantitative detectors—building on gravimetric principles. Nicolaus Cusanus proposed a simple balance loaded with wool to detect moisture absorption by weight differences around 1450 CE. refined this concept in his designs from the 1480s and early 1500s, sketching instruments in the that used absorbent materials like sponges, , or animal membranes suspended to show expansion or contraction in response to air , often integrated with mechanical linkages for visual indication. These devices operated on the principle of material deformation or weight variation due to , providing a qualitative sense of dampness for practical applications such as storing goods or . Despite their ingenuity, ancient and early hygroscopes were inherently limited to qualitative assessments, offering no numerical scales, standards, or reproducible measurements, which restricted their utility to indications of "" or "humid" conditions. These pre-scientific methods laid foundational empirical insights that influenced later quantitative developments in the .

18th and 19th Century Inventions

The 18th and 19th centuries marked a pivotal era in hygrometry, driven by Enlightenment-era scientific inquiry and the demands of the for precise environmental data. Inventors shifted from rudimentary qualitative indicators to instruments capable of quantitative assessment, laying the groundwork for modern . Key developments focused on absorption-based and evaporative principles, enabling reliable measurements of and supporting the expansion of observational networks. Swiss polymath advanced hygrometer design in the mid-18th century through his work on atmospheric . In 1755, he created one of the first practical hygrometers, employing organic materials for moisture absorption to detect changes in air . By 1769, Lambert published an extensive detailing the construction and of absorption hygrometers, including variants using threads and for chemical uptake of , which allowed for more synchronized readings with thermometers. These innovations emphasized empirical against known rates, providing a foundation for subsequent quantitative devices. A major breakthrough came in 1783 with Swiss physicist and geologist Horace Bénédict de Saussure's invention of the hair hygrometer. This device utilized stretched human hair as a hygroscopic , where length changes due to were mechanically linked to a scale for direct readings. Saussure calibrated his instrument against experiments, achieving accuracy sufficient for meteorological use, and patented variations that became standard in early weather stations. The hair hygrometer's simplicity and portability facilitated widespread adoption, influencing observations in and enabling the first systematic climate data collection. The early 19th century introduced psychrometric methods, with German inventor Ernst Ferdinand August patenting the psychrometer in 1818. This instrument paired two mercury thermometers—one dry and one with a wet bulb covered in —to measure the cooling effect of , from which relative could be calculated using empirical tables. August's represented the first dedicated use of mercury thermometers in such evaporative setups, improving over earlier wet-bulb concepts. Refinements followed, notably by French physicist Henri Victor Regnault in the , who enhanced wet-bulb accuracy through better and techniques, reducing errors in derivations to under 5% in controlled tests. Regnault's 1845 descriptions of improved psychrometers, including ether-based variants for dew-point verification, standardized the method for global meteorological stations. Overall, these 18th- and 19th-century inventions transformed hygrometry from an artisanal pursuit to a scientific tool, powering the establishment of national weather services and contributing to foundational climate records.

Mechanical Hygrometers

Hair Tension Types

Hair tension hygrometers operate on the principle that human or animal hair, composed primarily of keratin, is hygroscopic and undergoes reversible elongation when exposed to water vapor. As relative humidity (RH) increases, the hair absorbs moisture, causing its length to expand by approximately 2 to 3 percent from dry to saturated conditions, with a typical maximum elongation of about 2.5 percent at high RH levels. This dimensional change is mechanically amplified through a bundle of multiple hair strands, often 10 to 20, connected in parallel under tension to a spring-loaded lever system that drives a pointer across a calibrated dial, providing a direct analog reading of RH. These instruments are typically calibrated for an RH range of 20 to 80 percent, where they achieve an accuracy of ±3 percent, though performance is most reliable between 30 and 90 percent . Calibration involves adjusting the pointer against known humidity standards, such as saturated solutions, but readings can drift due to variations (optimal in 0 to 50°C) and gradual degradation from contaminants or repeated moisture cycles, necessitating periodic recalibration every few months. Key advantages of hair tension hygrometers include their low cost (often under $50 for basic models) and passive operation without requiring external power, making them suitable for portable or remote field use. However, they exhibit , where the hair's response lags during rapid changes, leading to errors up to 5 percent between adsorption and desorption cycles, and have a limited operational lifespan of 1 to 2 years before significant degradation reduces sensitivity. Since the 1940s, modern variants have incorporated synthetic fibers, such as nylon or polyimide, in place of natural hair to enhance stability, reduce hysteresis, and extend service life while maintaining the same tension-based mechanism. This innovation, building on the original hair tension design invented by Horace-Bénédict de Saussure in 1783, improves temperature resilience (up to -35 to +65°C) and minimizes maintenance needs compared to untreated hair.

Coil and Organic Material Types

Coil and material types of hygrometers rely on the hygroscopic of certain substances or composites, which expand or contract in response to changes in atmospheric , causing a structure to twist and indicate relative humidity (). These instruments typically feature spiral or helical constructed from materials such as whalebone, goldbeater's skin—an membrane derived from animal intestines—or paper strips impregnated with hygroscopic salts like . The degree of twist in the coil is directly proportional to RH levels, with some designs exhibiting angular changes of up to 90 degrees over the humidity range. In operation, one end of the is fixed, while the other is connected to a linkage, such as a pointer or lever arm, that traverses a calibrated dial to display readings. A notable early example is the metal-paper coil hygrometer, developed in the mid-19th century, which combines a thin strip of or coated with hygroscopic substances bonded to a ribbon formed into a tight ; absorption causes differential expansion between the organic layer and the metal, inducing torsion in the coil and movement of the indicator. This twisting mechanism amplifies small dimensional changes for practical measurement, similar in principle to the expansion seen in hair tension hygrometers but leveraging rotational dynamics for greater sensitivity in compact designs. Performance characteristics of these hygrometers include limited accuracy, typically with errors of ±10% or more RH, with reliable sensitivity across the 5–100% RH range, though optimal operation occurs between 10% and 90% RH where material responses are most linear. However, the organic components are susceptible to fatigue from repeated cycling, effects, and over time, necessitating regular recalibration—often annually—and protection from extreme temperatures or contaminants. These coil-based instruments found widespread application in analog recording devices, such as barographs and thermohygrographs, enabling continuous tracing of variations on chart paper alongside and ; their reliability supported meteorological observations until the widespread adoption of sensors in the .

Psychrometric Hygrometers

Wet-and-Dry Bulb Method

The wet-and-dry bulb method, also known as the psychrometric technique, measures relative by comparing the temperatures indicated by two s: a dry-bulb that records the ambient air T, and a wet-bulb covered with a wetted that cools to the T_w due to evaporative cooling. The difference between these temperatures, termed the wet-bulb depression D = T - T_w, arises from the required for from the wick, which is supplied by the surrounding air; this depression is larger in drier air where is more rapid. This method relies on the principle that the rate of is proportional to the difference between the at the wet-bulb and the actual in the air, allowing indirect determination of without direct measurement of content. The key relationship is given by the psychrometric equation for actual vapor pressure e: e = e_s(T_w) - A \cdot P \cdot D where e_s(T_w) is the saturation vapor pressure at the wet-bulb temperature, P is atmospheric pressure, and A is the psychrometric constant, approximately $6.66 \times 10^{-4} \, \mathrm{K^{-1}} for well-ventilated conditions at standard pressure. This equation derives from an energy balance at the wet-bulb surface, equating the sensible heat transfer from air to the bulb (proportional to D) with the latent heat of evaporation (proportional to the vapor pressure deficit e_s(T_w) - e), assuming steady-state conditions and Lewis relation between heat and mass transfer coefficients. The psychrometric constant A incorporates factors such as the specific heat of air, latent heat of vaporization, and the ratio of molecular weights of dry air to water vapor, making the formula semi-empirical but widely validated for practical use. To determine relative humidity (RH), the vapor pressure e is first computed from the equation, then RH is calculated as \mathrm{RH} = \frac{e}{e_s(T)} \times 100\%, where e_s(T) is the saturation vapor pressure at the dry-bulb temperature; this can be done using psychrometric charts, tables, or computational formulas for efficiency. The method requires proper ventilation around the wet bulb (typically 1-5 m/s airflow) to ensure accurate evaporation and minimize radiation errors, achieving an accuracy of approximately \pm 2\% RH under these conditions. The wet-and-dry bulb method was first described by James Hutton in 1792, and the term "psychrometer" was coined in 1818 by German physicist Ernst Ferdinand August; this technique remains a reference standard for humidity measurement due to its thermodynamic basis and reliability in controlled settings.

Aspirated and Sling Variants

Aspirated and sling psychrometers represent enhancements to the basic wet-and-dry bulb psychrometer, incorporating forced to accelerate from the wet bulb and achieve more reliable measurements in varying environmental conditions. These designs address limitations of stationary setups, where insufficient natural airflow can lead to prolonged stabilization times and inaccuracies due to uneven , by ensuring consistent air movement over the thermometers. The sling psychrometer consists of a pivoted frame holding a dry-bulb and a wet-bulb covered with a moistened , rotated manually by the user to generate . Operation involves whirling the device at 120 to 180 for approximately 1 to 1.5 minutes until the wet-bulb temperature stabilizes, after which readings are taken to calculate relative humidity using psychrometric tables or charts. This method reduces measurement time compared to non-ventilated versions and minimizes errors from ambient air currents by promoting uniform evaporation. Aspirated psychrometers employ mechanical means to drive air past the thermometers, providing greater precision for professional applications such as . The Assmann psychrometer, developed by Aßmann in the late , uses a to maintain an airflow speed of 3 to 5 meters per second across the bulbs, enclosed in radiation shields to further reduce external influences. This design became a standard for stations, enabling accurate assessments in field conditions where manual operation is impractical. These variants offer improved accuracy, typically achieving relative humidity measurements within ±2% when properly maintained and operated by trained users, outperforming non-aspirated methods in low-airflow environments. Specific protocols emphasize wick maintenance and whirling in areas with minimal ventilation to ensure consistent results, as outlined in standards for environmental monitoring. Modern adaptations retain the thermodynamic principle of wet-bulb depression but incorporate thermometers and built-in fans for automated aspiration, simplifying operation while preserving portability for fieldwork. Devices like fan-assisted psychrometers maintain airflow rates similar to traditional models, displaying relative directly without manual calculations.

Modern Sensor-Based Hygrometers

Capacitive and Resistive Sensors

Capacitive hygrometers operate on the principle that a hygroscopic material, typically a or film, is sandwiched between two electrodes to form a . As relative (RH) increases, is absorbed by the dielectric, raising its and thus increasing the in proportion to the RH level. This relationship is often modeled by the equation \frac{\Delta C}{C_0} = k \times \mathrm{RH}, where \Delta C is the change in capacitance, C_0 is the baseline , k is the factor (typically around 0.2–0.5 /% depending on the ), and RH is expressed as a . These sensors achieve accuracies of ±2% over a wide range and exhibit fast response times of less than 10 seconds for a 63% step change under typical conditions. Resistive hygrometers, in contrast, measure through changes in electrical of a hygroscopic film, such as , deposited on an insulating between conductive electrodes. by the increases ionic , thereby decreasing exponentially with rising RH. These sensors are favored for low-cost applications due to their simple construction but are susceptible to contamination and drift, limiting long-term stability. The development of thin-film capacitive and resistive s accelerated in the with advances in , enabling compact designs; dielectrics like polyimides enhanced sensor durability and into systems. Early thin-film capacitive sensors, such as Vaisala's HUMICAP introduced in 1973, built on this foundation to provide reliable electronic alternatives to mechanical hygrometers. In comparison, capacitive sensors are preferred for their superior long-term stability and full-range operation from 0% to 100% , while resistive types offer greater simplicity and lower power consumption for disposable or short-term uses. Both types outperform mechanical methods in response speed but require periodic against reference standards like gravimetric techniques to maintain accuracy.

Thermal and Gravimetric Methods

Thermal hygrometers operate on the principle that the thermal conductivity of air varies with its content, as has a lower thermal conductivity than dry air (approximately 0.016 W/m·K for versus 0.026 W/m·K for dry air at 25°C). This results in the thermal conductivity λ of moist air decreasing proportionally with increasing absolute . The typical setup employs a dual- configuration: two identical hot-wire or thin-film thermistors or resistors serve as heating and sensing elements. One is exposed to the sample gas (moist air), while the other acts as a reference in dry air or a controlled dry . The difference in dissipation, manifested as a change in electrical due to cooling rates, is measured. The absolute is then calculated from the ratio of thermal conductivities, often using the relation \rho_v = \frac{\lambda_{dry} - \lambda_{sample}}{k}, where \rho_v is the density, \lambda_{dry} and \lambda_{sample} are the thermal conductivities of dry and sample air, respectively, and k is a constant derived from the \frac{d\lambda}{d\rho_v}. These devices achieve accuracies of ±1% relative (RH) in the range of 0-50% RH, making them suitable for precise absolute measurements. Thermal hygrometers find applications in monitoring humidity in clean gases, such as in semiconductor manufacturing processes or high-purity gas analysis, where contamination-free environments are essential. However, they exhibit limitations, including slow response times for transient humidity changes due to the diffusive nature of thermal equilibration, typically on the order of seconds to minutes. Gravimetric hygrometers represent the gold standard for humidity measurement, providing direct traceability to SI units by quantifying the mass of water vapor in a known volume of air. The procedure involves passing a measured volume of sample gas through an absorbing medium, such as phosphorus pentoxide (P₂O₅) or magnesium perchlorate, which chemically binds the water vapor. The increase in mass of the absorbent is precisely weighed using a microbalance, and the absolute humidity is computed as the ratio of absorbed water mass to the gas volume, adjusted for temperature and pressure. This method aligns with standardized protocols like ASTM E104 for controlled humidity environments, though it is primarily executed in laboratory settings with high-precision volumetric flow control. Uncertainties are exceptionally low, typically below 0.2% RH, enabling their use in calibrating other hygrometer types, including capacitive sensors. Gravimetric methods ensure for national institutes, supporting applications in standards validation and high-accuracy environmental testing. Their primary limitations include the destructive nature of the process, which prevents monitoring, and confinement to use due to the need for extended equilibration times—up to several hours at low humidities—and specialized equipment.

Optical and Chilled Mirror Types

Optical hygrometers measure concentration by detecting the absorption of light at specific wavelengths, such as approximately 1.37 μm, where exhibits strong absorption lines. This approach leverages the principle that the amount of light absorbed is proportional to the number of molecules along the optical path. Tunable diode laser (TDLS) is a widely adopted in optical hygrometers, enabling high-precision measurements with accuracies reaching parts per million () volume mixing ratios in the upper and lower . For instance, intercomparisons of TDLS-based instruments have demonstrated good agreement during airborne campaigns. The fundamental equation governing in these systems is the Beer-Lambert law, expressed as
I = I_0 \exp(-\sigma \times N \times L),
where I is the transmitted , I_0 is the initial intensity, \sigma is the absorption cross-section of at the selected , N is the density of molecules, and L is the . By tuning the diode laser to a absorption line and measuring the , the or mixing ratio of can be derived with minimal from other atmospheric gases.
Chilled mirror hygrometers provide a direct measurement of dew point temperature by cooling a polished mirror surface until water vapor condenses as dew or frost, at which point the condensation scatters light and is detected optically. A feedback servomechanism, typically using a photodetector and thermoelectric cooler, automatically adjusts the mirror temperature to maintain the exact onset of condensation, ensuring the measured temperature corresponds to the dew point. These instruments achieve high accuracy, with uncertainties as low as ±0.1°C in dew point temperature, and are traceable to national standards through calibration. Response times typically range from 1 to 5 minutes, depending on airflow and humidity levels, making them suitable for steady-state monitoring. Recent developments include Peltier-based non-cryogenic chilled mirror designs, such as the SKYDEW hygrometer introduced in 2025, which eliminates the need for liquid coolants and enables reliable measurements from the surface up to 25 km altitude in the . This innovation supports applications in and high-altitude research by providing robust performance without cryogenic maintenance. Both optical and chilled mirror types offer advantages over other sensors, including insensitivity to common contaminants like or oils that could affect or capacitive devices, and operational ranges spanning -75°C to +50°C or wider in advanced configurations. They are particularly valued in environments and meteorological stations for their precision in low-humidity conditions, often serving as standards calibrated against gravimetric methods for absolute accuracy.

Applications

Meteorology and Environmental Monitoring

In meteorology, hygrometers are integral to automated weather stations, where they provide essential relative humidity () data for prediction. The (WMO) recommends the use of aspirated psychrometers in surface observations to ensure accurate and minimize errors from natural airflow variations, aligning with standards outlined in to Instruments and Methods of Observation (WMO-No. 8). These instruments are often integrated into shielded enclosures at standard heights of 1.25 to 2 meters above ground, feeding data into global networks for real-time analysis. Capacitive sensors have also become prevalent in modern automated systems, offering robust performance for continuous RH monitoring with uncertainties typically below 5% in operational ranges. For climate research, hygrometers play a in upper-atmosphere profiling via , particularly chilled-mirror types that deliver precise dew-point measurements essential for understanding distribution. Devices like the Snow White chilled-mirror hygrometer have been validated in WMO intercomparisons, showing superior accuracy in the compared to thin-film sensors, with frost-point errors under 0.5°C. The NOAA Frost Point Hygrometer (FPH), deployed on balloon-borne platforms, contributes to long-term records at sites like , and , enabling detection of humidity trends linked to , such as increases in tropospheric that amplify the . These observations support models by quantifying moisture feedback mechanisms, with historical radiosonde data revealing a 1–5% per decade rise in mid-tropospheric specific humidity since the . In , hygrometers assess moisture levels influencing ecological and air quality dynamics, such as in controlled agricultural settings like greenhouses where data guides to prevent fungal diseases and optimize . NOAA's Global Monitoring Laboratory operates humidity networks using FPH instruments to track vertical profiles, aiding studies on how modulates pollutant lifetimes, for instance, in ozone formation during high-moisture events. This data integrates into broader ecological assessments, revealing correlations between elevated and reduced visibility in urban-rural interfaces. Hygrometer outputs, including and dew-point values, are routinely incorporated into psychrometric charts to forecast phenomena like formation and , where dew points near surface temperatures signal risks. In operational , these charts visualize air properties to predict onset when RH exceeds 90%, enhancing and road safety alerts through models like those from the .

Industrial and Consumer Uses

In industrial settings, hygrometers equipped with capacitive sensors are integral to HVAC systems, particularly in data centers where they maintain levels between 40% and 60% to prevent and equipment . These sensors provide real-time feedback to automated s, optimizing while ensuring operational uptime. In and , hygrometers monitor humidity to avert spoilage and ensure product stability, with digital models offering accuracy of ±1-2% RH to comply with regulatory standards like those from the FDA. For instance, in pharmaceutical environments, precise RH prevents moisture-induced of active ingredients during and . Consumer applications of hygrometers span everyday home use and specialized hobbies. Digital thermo-hygrometers featuring connectivity for remote monitoring via apps allow users to track indoor humidity and temperature for comfort and health. In niche areas like cigar humidors, analog hair hygrometers remain popular for their reliability in maintaining 65-75% to preserve quality without power requirements. Similarly, in reptile terrariums, analog hair-based hygrometers, such as those from Exo Terra, help sustain optimal humidity levels (often 50-80%) essential for amphibian and health. Market trends highlight the rise of IoT-integrated smart hygrometers, which enable remote monitoring and AI-driven analytics for predictive adjustments in both and devices as of 2025. The global hygrometer market, valued at approximately $1.2 billion in 2024, is projected to reach $2.5 billion by 2033, driven by demand for connected sensors in smart homes and automation. These devices also play a critical role by preventing in sensitive , where RH exceeding 60% can lead to short circuits, and in museums, where they safeguard artifacts from and material expansion by stabilizing RH at 40-55%.

Calibration and Standards

Psychrometric Calibration

Psychrometric calibration employs a psychrometer as a transfer to verify and adjust the accuracy of test hygrometers, relying on the thermodynamic principles of evaporative cooling to determine relative humidity () from dry-bulb and wet-bulb temperature measurements. This method is particularly suited for mid-range RH levels, where the psychrometer's readings, derived from wet-bulb depression, serve as the in a controlled environment. The procedure involves placing both the reference psychrometer and the test hygrometer in a - and humidity-controlled chamber to generate stable conditions. The psychrometer's is measured under forced to ensure adiabatic , and the resulting wet-bulb (the difference between dry-bulb and wet-bulb temperatures) is used to calculate RH via standardized tables or calculators, such as those provided by NOAA, which tabulate RH values for given temperature differences at various dry-bulb temperatures. The test hygrometer's output is then compared directly to these calculated RH values from the psychrometer. Calibration steps typically include exposing both instruments simultaneously at multiple RH set points, such as 20%, 50%, and 80%, to cover a representative range and assess . Airflow over the psychrometer must be maintained above 4 m/s to achieve accurate wet-bulb readings, as recommended by ISO standards for psychrometric measurements. Following exposure at each point, readings are recorded after stabilization (usually 10-15 minutes), and deviations are noted for adjustment or correction factors. An is conducted in accordance with ISO/IEC 17025, evaluating contributions from errors (typically 0.15-0.3°C for dry-bulb and 0.15-1.0°C for wet-bulb), variability, and psychrometer wick condition, yielding overall RH uncertainties of 1-2% in standard calibrations. This approach offers advantages in portability, as psychrometers can be used in field or settings without complex equipment, and its thermodynamic foundation ensures traceability to primary standards. It is specifically effective for the 5-95% RH range, where wet-bulb depression provides reliable RH inference without needing absolute humidity references. However, psychrometric calibration requires skilled operation to properly wick the thermometer, maintain , and interpret tables accurately, as small errors in can amplify uncertainty up to 11% at larger depressions. It is unsuitable for trace humidity levels below 5% , where evaporation effects diminish; in such cases, brief reference to salt-based methods may supplement for lower ranges.

Chemical and Reference Methods

Chemical methods for hygrometer calibration rely on the establishment of known relative humidity (RH) levels through chemical equilibria, providing stable reference environments for accurate verification. Saturated salt solutions are commonly used to generate these fixed RH points, where the vapor pressure equilibrium over a saturated aqueous solution of a specific salt maintains a constant RH at a given temperature. For instance, lithium chloride (LiCl) solutions yield approximately 11% RH, while sodium chloride (NaCl) solutions produce about 75% RH at 20°C. These setups are typically conducted in sealed desiccators or chambers as outlined in ASTM E104, ensuring the hygrometer sensor is exposed to the equilibrium atmosphere until readings stabilize, often achieving a precision of ±0.5% RH over 24 hours. Gravimetric reference methods offer primary standards for calibration by directly measuring the of in a gas stream, ensuring to the () through fundamental physical principles. In this approach, a known volume of dry gas is saturated with , and the exact of condensed is determined using high-precision balances, allowing calculation of the absolute content. The two-pressure enhances this by generating precise levels: a gas stream is first saturated at a low and elevated , then expanded to ambient conditions, where the resulting of corresponds to a known or . This technique underpins SI-traceable calibrations for hygrometers requiring high accuracy, such as those used in labs. International standards bodies like the National Institute of Standards and Technology (NIST) and the (PTB) provide protocols for these chemical and reference methods to ensure global consistency. NIST employs humidity generators based on permeation tubes, where is released at a controlled rate from a liquid-permeated into a carrier gas, producing traceable concentrations from 0.1 to 10,000 parts per million () for low-humidity calibrations. PTB guidelines, such as DKD-R 5-8, specify procedures for direct comparison of hygrometers against these primary references in controlled environments, emphasizing uncertainty evaluation and environmental conditioning. Traceability in humidity measurements is maintained through calibration chains that link working sensors to primary standards, forming an unbroken sequence of comparisons with documented uncertainties. Primary gravimetric or two-pressure systems serve as the top level, calibrating transfer standards like chilled-mirror hygrometers, which in turn validate secondary working instruments in field or industrial settings. This hierarchical structure, as defined by metrological principles, ensures that all humidity readings can be related back to units via national institutes.

Measurement Challenges

Sources of Error

Hygrometers are susceptible to environmental factors that introduce inaccuracies in relative humidity (RH) measurements. Temperature cross-sensitivity is a primary concern, particularly in capacitive and resistive sensors, where temperature variations alter the sensor's electrical properties and lead to RH errors. Contamination from dust, oils, or chemical residues can adhere to the sensing elements of capacitive sensors, causing drift or offset errors by altering the dielectric properties of the polymer film. These effects are exacerbated in industrial or outdoor environments with airborne particulates, potentially leading to measurement deviations of several percent RH without regular cleaning or protection. Material-related errors stem from the inherent properties of the sensing medium. In mechanical hygrometers, can occur due to delayed responses to changes. Resistive sensors, relying on hygroscopic salts or polymers that change with , experience long-term drift from material degradation or ion migration. Operational factors further compound inaccuracies during deployment. In psychrometers, inadequate reduces from the wet bulb, elevating its temperature and causing RH overestimation by up to +5% at low speeds below 1 m/s, as the assumed psychrometric coefficient becomes invalid. Field measurements are also affected by solar radiation, which can heat exposed sensors by 2-5°C, indirectly biasing RH readings through temperature-dependent sensitivity or uneven heating of psychrometer bulbs. Quantifying these errors involves constructing an budget that combines systematic and random components, typically calculated as the total uncertainty u = \sqrt{u_{\text{systematic}}^2 + u_{\text{random}}^2}, where systematic errors arise from biases like cross-sensitivity and random errors from noise or variability. According to (WMO) guidelines, overall RH measurement uncertainty in operational settings can reach 5% at 95% confidence, incorporating contributions from environmental, material, and operational sources in instruments like radiosondes or surface stations. can help mitigate these, but unaddressed errors persist in uncorrected deployments.

Recent Advances in Accuracy

Recent advances in hygrometer technology have focused on digital enhancements, particularly through miniaturized micro-electro-mechanical systems () sensors that achieve accuracies as low as ±0.5% relative humidity (RH) in controlled conditions, enabling compact integration into portable devices. These sensors leverage capacitive principles with improved dielectric materials to minimize and enhance long-term stability, addressing traditional limitations in for and applications. Furthermore, integration with (IoT) connectivity allows for real-time data transmission to cloud platforms, where as of 2025 algorithms apply predictive models to correct sensor drift, reducing cumulative errors by up to 50% over extended deployment periods. Innovative developments include the SKYDEW, a Peltier-based chilled-mirror hygrometer introduced in 2025, designed for portable measurements from the troposphere to the lower stratosphere without cryogenic cooling, offering dew-point accuracies better than 0.2°C in low-humidity environments. This non-cryogenic approach uses digital control of the Peltier element to maintain a thin dew or frost layer on the mirror, enabling reliable operation in high-altitude balloons and aircraft with reduced power consumption compared to traditional systems. Complementing this, radio-frequency (RF) sensors have emerged for non-contact humidity measurement, such as chipless RFID designs operating at 2.45 GHz, which detect environmental moisture through changes in resonant frequency without physical interaction, achieving sensitivities suitable for remote monitoring in agriculture and storage. Sensor integration has advanced through multi-sensor fusion techniques, combining hygrometers with and sensors in smartphones to provide comprehensive environmental profiles via onboard , as seen in devices like those using Bosch's BME280 module for synchronized RH, , and barometric data. This fusion employs algorithms to cross-validate readings, improving overall accuracy in dynamic conditions like assessment. Additionally, models for predictive calibration analyze historical data patterns to forecast and adjust for environmental influences, with techniques demonstrating errors as low as 3.188% RH in low-cost networks. These innovations have significantly impacted consumer devices, reducing measurement errors to below 1% in many integrated systems through enhanced materials and software corrections, driving market growth in smart home applications as of 2025. A key example is Bosch's 2025 GDH 1-17 thermo-hygrometer, which features app integration via for real-time logging and analysis of humidity alongside and absolute moisture, facilitating proactive environmental management in professional settings.

References

  1. [1]
    Weather Forecasting Through the Ages - NASA Science
    Feb 25, 2002 · The first known design in western civilization for a hygrometer, an instrument to measure the humidity of air, was described by Nicholas Cusa (c ...Missing: definition | Show results with:definition
  2. [2]
    [PDF] WEATHER INSTRUMENT HISTORY
    During the middle of the 15th century the German mathematician Cardinal Nicholas deCusa invented the hygrometer for measuring humidity by calculating the weight.Missing: definition | Show results with:definition
  3. [3]
    [PDF] An improved electric hygrometer - NIST Technical Series Publications
    The psychrometer and hair hygrometer are common means of determining the moisture content of air. There are, however, many circumstances to which.
  4. [4]
    How We Measure Meteorology - Air (U.S. National Park Service)
    Aug 7, 2025 · Relative humidity is measured using a hygrometer. The hygrometer (shown on the left) works by using the principles of capacitance. The ...Missing: definition | Show results with:definition
  5. [5]
    [PDF] Electric Hygrometers - GovInfo
    An electric hygrometer measures air moisture by measuring the electrical resistance of a hygroscopic material with humidity changes.
  6. [6]
    Gravimetric Hygrometer | NIST
    Aug 14, 2025 · A gravimetric hygrometer measures humidity by separating the water from the gas and subsequently determining the masses of the water and the gas ...Missing: definition | Show results with:definition
  7. [7]
    [PDF] Application information on typical hygrometers used in ... - GovInfo
    A general review of hygrometer literature has been provided and the most commonly used ones for HVAC are discussed. Typical hygrometer parsimeters are listed to ...
  8. [8]
    Hygrometers | NIST - National Institute of Standards and Technology
    The NIST Hybrid Humidity Generator (HHG) provides calibration services for a variety of humidity–measuring instruments.
  9. [9]
    [PDF] Calibration of Hygrometers with the Hybrid Humidity Generator
    The NIST Hybrid Humidity Generator (HHG) generates frost/dew points from –70 °C to +85 °C using two-pressure and divided-flow techniques.
  10. [10]
    Humidity and moisture measurement - NPL
    Hygrometers are used to measure the amount of water vapour, or humidity, and there are at least twenty measuring principles for hygrometers, whose ...
  11. [11]
    Relative Humidity - HyperPhysics
    The relative humidity is the percent of saturation humidity, generally calculated in relation to saturated vapor density. The most common units for vapor ...Missing: law | Show results with:law
  12. [12]
    Temperature - Dry Bulb/Web Bulb/Dew Point
    The Dew Point is the temperature at which water vapor starts to condense out of the air, the temperature at which air becomes completely saturated. Above this ...
  13. [13]
    [PDF] Thermodynamics of Moist Air
    The relation between vapor pressure and absolute humidity is given by the ideal gas law for pure water vapor, (11).
  14. [14]
    13.6 Humidity, Evaporation, and Boiling - College Physics 2e
    Jul 13, 2022 · If the partial pressure is less than the vapor pressure, then evaporation will take place, as humidity is less than 100%.
  15. [15]
    Hygrometer - Etymology, Origin & Meaning
    Originating from Greek hygro- "moisture" and French hygromètre (1660s), the word means an instrument for measuring atmospheric moisture.
  16. [16]
    Dew Point vs Humidity - National Weather Service
    The dew point is the temperature the air needs to be cooled to (at constant pressure) in order to achieve a relative humidity (RH) of 100%.
  17. [17]
    Air - Humidity Ratio - The Engineering ToolBox
    Humidity ratio is normally expressed in kilograms (or pounds) of water vapor per kilogram (or pound) of dry air. Humidity ratio expressed by mass: x = mw / ma ( ...
  18. [18]
    3.1 Ways to Specify Water Vapor | METEO 300 - Dutton Institute
    But specific humidity is less than the water vapor mixing ratio if the humidity is more than zero. Here is one example of global specific humidity. world map ...
  19. [19]
    [PDF] Dew Point Temperature: Teacher Guide - TAHMO
    Calculations: Calculate dew point temperature for one day using the following formula: Td = T – ((100 – RH)/5). Where; RH = Relative Humidity (in percent). Td ...
  20. [20]
    Improved Magnus Form Approximation of Saturation Vapor Pressure ...
    A goal of this work was to develop a uniform and accurate method to convert these data to various humidity variables without regard to the equations used in ...
  21. [21]
    Mesoscale Analysis - Info - National Weather Service
    Since dew point is a direct measure of the actual moisture content in the air, it is the preferred unit of moisture measurement in meteorology.
  22. [22]
    Frost Point - an overview | ScienceDirect Topics
    Frost point is defined as the temperature to which a given amount of humid air must be cooled, at constant atmospheric pressure, for water vapor to be ...
  23. [23]
    the development of scientific hydrological concepts in Greek ... - HESS
    May 10, 2021 · While the early attempts were unsuccessful, Aristotle was able to formulate a correct hypothesis, which he tested through what appears to be the ...
  24. [24]
    Studies on historical gravimetric hygrometers - ScienceDirect.com
    From Leonardo da Vinci (1452–1519), we have drawings of gravimetric hygrometers, equipped with either a sponge or cotton.Missing: primary | Show results with:primary
  25. [25]
    [PDF] Early Hydraulic Civilization in Egypt
    On several floodplains of the Old World, the development of irrigation farming and urbanism appear to have gone hand in hand to produce a number of ...
  26. [26]
    [PDF] Johann Heinrich Lambert - University of St Andrews
    Aug 16, 2021 · In 1755, for example, he invented the first usable hygrometer to measure the humidity of the air (LEONARDO DA VINCI's invention from 1480 had ...
  27. [27]
    [PDF] Johann Lambert's Scientific Tool Kit. - HAL-SHS
    Jan 26, 2012 · In 1769 Lambert devoted a long essay to the measurement of humidity and the construction, fine- tuning and 'synchronisation' of a measuring ...Missing: 1766 | Show results with:1766
  28. [28]
    De Saussure Hair Hygrometer, 1815-1841
    In 1783, Horace Benedict de Saussure, a Swiss physicist and geologist, made the first hair hygrometer, using a human hair to measure humidity.
  29. [29]
    Essais sur l'Hygromètrie | Horace Benedict de SAUSSURE
    10-day deliveryHe invented the hair hygrometer - the only type of absorption hygrometer ... In 1783 this work appeared simultaneously in octavo and quarto format, but by ...
  30. [30]
    In depth - Hygrometer - Museo Galileo
    The term psychrometer, coined in 1818 by the German inventor Ernst Ferdinand August (1795-1870), derives from the Greek and means "cold measurer." It is a ...
  31. [31]
    [PDF] methods of measuring humidity and testing hygrometers - GovInfo
    This circular reviews methods for measuring water-vapor content, including psychrometry, mechanical, dewpoint, electrical, gravimetric, thermal conductivity, ...Missing: history scholarly
  32. [32]
    Make a Hygrometer with Strands of Hair | Science Project
    ... percent as the humidity goes from 0 to 100 percent. While that is only a smidgen of length, the rate of this change is very dependable, so it is possible to ...
  33. [33]
    [PDF] 19690000832.pdf - NASA Technical Reports Server (NTRS)
    hair hygrometer is useful over a very narrow range of temperature :6: -30 to +150oF and reliability is doubtful below OOF. Therefore, the hair hygrometer is ...
  34. [34]
    [PDF] Anaesthesia
    hair hygrometer. This is based on the principle that the length of the hair increases with increasing humidity. It is fairly accurate between 30 and. 90%. Wet ...
  35. [35]
    [PDF] Handbooks-Vol-2-Chapter-3-Mechanical-Hygrometer.pdf
    Feb 7, 2019 · FIGURE 3.6 The drawings present in the museums describ- ing the work of a hair hygrometer. ... scopic polymer, such as nylon, polyimide plastic, ...
  36. [36]
  37. [37]
    Output of a capacitive or a resistive hygrometer for a sudden change ...
    hair sensor suffers from a large hysteresis ( Fig. 9) and its output can depart significantly from linearity. The readout can be based on a linear or a non ...<|control11|><|separator|>
  38. [38]
    [PDF] INSTRUMENTATION FOR MEASUREMENT OF MOISTURE
    ties of hair. Considering the technological advances made in modern times, it is surprising that the hair hygrometer introduced by de Saussure in 1783 is ...<|control11|><|separator|>
  39. [39]
  40. [40]
    US183062A - Improvement in hygrometers - Google Patents
    I have discovered that if a whalebone is coiled in a helical coil, that fact does not seriously interfere with its twisting action with the changes of moisture.
  41. [41]
    [PDF] Methods of Measuring Humidity and Testing Hygrometers - DTIC
    Methods include psychrometry, mechanical, dewpoint, electrical, gravimetric, thermal conductivity, index of refraction, pressure/volume, and dielectric ...
  42. [42]
    Types of Hygrometers
    Metal-Paper Coil Hygrometer. In this hygrometer, water vapor absorbed by a salted paper strip attached to a metal coil causes the coil to change shape.Missing: Lamont 1847
  43. [43]
    Hygrometer | PDF | Humidity | Atmospheric Sciences - Scribd
    Metal-paper coil type. The metal-paper coil hygrometer is useful for giving a dial indication of humidity changes. ... whalebone hygrometer (MHS Geneva) It ...<|separator|>
  44. [44]
    [PDF] Measurement and Instruments
    Its response time is also very slow; it takes approx- imately 2 min for a 67% step change. MECHANICAL HYGROMETERS. Many organic materials change in dimension ...
  45. [45]
    Measuring Air Humidity | Whipple Museum - University of Cambridge
    First developed in 1755 by William Cullen (1710-1790) and Joseph Black (1728-1799), wet and dry bulb hygrometers measured humidity based on the evaporation of ...
  46. [46]
    psychrometric formula
    Semi-empirical formula used in the preparation of psychrometric tables: e' = ew ñ Ap(T ñ Tw), where e' is the vapour pressure under the observation conditions; ...
  47. [47]
    psychrometric constant, meteorology, climatology, hydroclimatology ...
    Mar 11, 2014 · in which cp = specific heat of air at constant pressure, in cal gr-1 °C-1; p = atmospheric pressure, in mb; rMW = ratio of the molecular weight ...
  48. [48]
    Wet/Dry-Bulb Technology Explained | Humidity Academy 7
    According to this standard, the accuracy which can generally be expected in the case of a ventilated dry- and wet-bulb device is in the range of 2 to 5 %rh. The ...
  49. [49]
    [PDF] Using A Psychrometer To Measure Relative Humaidity
    The sling psychrometer is a hand-operated device, while the aspirating psychrometer is usually battery powered, although wind-up models exist. These ...Missing: RPM time
  50. [50]
    Sling Psychrometer - an overview | ScienceDirect Topics
    In order that consistent conditions can be obtained, the air speed over the thermometers should be not less than 1 m/s. This can be done with a mechanical ...
  51. [51]
  52. [52]
    (PDF) Aßmann's development of aspiration psychrometers
    Aug 6, 2025 · Aßmann's aspiration psychrometer for atmospheric humidity measurements was developed between 1886 and 1889. This development was documented ...
  53. [53]
    Measuring the temperature of the air (Chapter 5)
    May 21, 2024 · Figure 5.5 The Assmann psychrometer, first described in 1887, is a simple device which enabled high-accuracy aspirated measurements of air ...
  54. [54]
    Assmann Psychrometer, Mercury Type, 0 to 50°C - 佐藤計量器製作所
    Airflow speed, 3 to 5 m/s. Dimensions, 80 (W) x 450 (H) x 110 (D) mm. Weight, 740 g including batteries. Power, D battery x2 or attached AC adapter. Standard ...
  55. [55]
    [PDF] Using A Psychrometer To Measure Relative Humidity
    Sling psychrometers are the standard for accurately measuring ambient temperature and humidity. Every meteorologist should know how to use one correctly. 1.Missing: RPM | Show results with:RPM
  56. [56]
    Standard Test Method for Measuring Humidity with a Psychrometer ...
    Feb 16, 2023 · This standard provides guidelines for measuring humidity using wet- and dry-bulb temperatures, using a psychrometer, for atmospheric air.<|separator|>
  57. [57]
    225-565-A Fan Psychrometer Celsius (limited supply)
    The 225-564 Fan Psychrometer is used for determination of dew point and relative humidity. It consists of 9.5-inch dry and wet bulb thermometers.
  58. [58]
    What is a Psychrometer and How to Use One - Parameter
    Aug 17, 2023 · Sling psychrometers consist of two thermometers (dry-bulb and wet-bulb) mounted on a rotating frame or handle. When using a sling psychrometer, ...Missing: RPM | Show results with:RPM<|separator|>
  59. [59]
    Humidity Academy Theory 6: How Capacitive Sensors Measure ...
    The capacitive humidity sensor consists of a hygroscopic dielectric material placed between a pair of electrodes that forms a small capacitor.
  60. [60]
    [PDF] MEMS Humidity Sensors - SciSpace
    ΔC/C. ΔRH. (3) where ΔC is the capacitance change due to humidity, C is the nominal capaci- tance, and ΔRH is the relative humidity variation. For a quick ...
  61. [61]
    The Basics Behind a MEMS Capacitive Humidity Sensor
    Sep 30, 2022 · Typical specs are 63% response in 5 to 10 seconds with 1 meter per second airflow. Sensors with protective filter covers will be much slower, ...
  62. [62]
    Humidity Sensors Principle, Mechanism, and Fabrication ... - NIH
    Resistive sensors measure the change of the humidity and translate it into a change in electrical impedance of the hygroscopic medium. Typically, the change of ...
  63. [63]
    Humidity Sensors – Resistive or Capacitive? - Zurich Instruments
    Jun 15, 2020 · This process is more linear than proton jumping, meaning the capacitive humidity sensor should have a higher precision than the resistive ...
  64. [64]
    Article - CHOOSING A HUMIDITY SENSOR — Ohmic Instruments Inc.
    The response time ranges from 30 to 60 s for a 63% RH step change. State-of-the-art techniques for producing capacitive sensors take advantage of many of the ...
  65. [65]
    The importance of humidity sensors - Vaisala
    ... developed the world's first thin-film polymer-based capacitive humidity sensor in 1973. How the humidity sensors work. The modern capacitive humidity sensor ...
  66. [66]
  67. [67]
    [PDF] The second-generation NIST standard hygrometer
    Apr 1, 2010 · The second-generation NIST hygrometer uses a gravimetric method, separating water from gas, measuring mass ratio, and has automated continuous ...
  68. [68]
    [PDF] methods of calibration and testing of hygrometers - GovInfo
    An experimental set-up for making a moisture determination with the gravimetric method is shown in Figure 1. Air of constant water vapor content is produced by ...
  69. [69]
    [PDF] Chapter 3 – Humidity
    Evaporation rate (E) is directly pro- portional to the vapor saturation difference be- tween the wet surface (leaf) and surrounding atmosphere: E = VSD r¹ ...
  70. [70]
    Aura Validation Experiment - IMPACT - NASA
    It uses a tunable diode laser operating at 1.37 μm to measure atmospheric water vapor in the upper troposphere and lower stratosphere. JLH has a minimum spatial ...
  71. [71]
    [PDF] Optical and Remote Sensing for Measurement and Monitoring of ...
    tunable diode laser absorption spectroscopy. UV ultraviolet. VOCs volatile ... is given by the Beer-Lambert law, which is used to approximate the minimum ...
  72. [72]
    Dew Point Temperature - University of Wyoming
    Chilled mirror operating principles are exceptionally reliable and inherently repeatable. A chilled mirror hygrometer consists of a temperature-controlled ...
  73. [73]
    [PDF] Chilled Mirror Hygrometer Aboard Aircraft (CMH-AIR) Instrument ...
    The temperature of the mirror is, by definition, equal to the dew or frost point temperature. The temperature is measured with an analog-to-digital ...
  74. [74]
    [PDF] RADC/NBS international workshop moisture measurement and ...
    ... Accuracy and Reproducibility of the Mass Spectrometer/ Carousel Method ... total water and water vapor in the free volume. However, for a specific ar ...<|separator|>
  75. [75]
    Development of a Peltier-based chilled-mirror hygrometer, SKYDEW ...
    Jan 28, 2025 · We have developed a Peltier-based non-cryogenic chilled-mirror hygrometer named SKYDEW to measure water vapor from the surface to the stratosphere.
  76. [76]
    [PDF] THE NEW NIST LOW FROST-POINT HUMIDITY GENERATOR
    Thus, using a chilled mirror hygrometer, accurate measurements of saturator temperature and pressure as well as barometric pressure are required. See Eq. 2.
  77. [77]
    [PDF] PART I MEASUREMENT OF METEOROLOGICAL VARIABLES
    4.6 Electrical resistive and capacitive hygrometers ... achievable uncertainty of solid-state sensors may show significant temperature and humidity dependence.
  78. [78]
    Analysis of Relative Humidity Sensors at the WMO Radiosonde ...
    The good performance of the SW chilled-mirror hygrometer sensor in the tropo- sphere was demonstrated by Fujiwara et al. (2003) and. Wang et al. (2003a).Missing: upper | Show results with:upper
  79. [79]
    Advancements, measurement uncertainties, and recent ... - NIH
    The NOAA frost point hygrometer (FPH) is a balloon-borne instrument flown monthly at three sites to measure water vapor profiles up to 28 km.
  80. [80]
    An Analysis of Tropospheric Humidity Trends from Radiosondes in
    A new analysis of historical radiosonde humidity observations is described. An assessment of both known and unknown instrument and observing practice changes ...
  81. [81]
    [PDF] Instruments for Monitoring the Greenhouse Aerial Environment
    Until the condensation is evaporated, the hygrometer will often display inaccurate humidity. Page 3. 3 readings or there may be a permanent change in electrical.
  82. [82]
    GML Water Vapor - Global Monitoring Laboratory - NOAA
    The NOAA Frost Point Hygrometer (FPH) has evolved from an analog unit with strip chart recording of data to a digitally controlled instrument with full downlink ...Missing: environmental | Show results with:environmental
  83. [83]
    5.4 Dew point and relative humidity - Meteorology - Fiveable
    Dew point always lower than or equal to air temperature as relative humidity approaches 100%; Dew point directly measures atmospheric moisture content while ...
  84. [84]
    ASHRAE Data Center Temperature & Humidity Guidelines - TSG
    Feb 8, 2023 · The minimum Relative Humidity (RH) is 20%. The maximum RH is 80%. The maximum dew point is 22°C. The rate of change of temperature is less than ...
  85. [85]
    Understanding Humidity Monitoring in the Data Center - Packet Power
    Discover how humidity monitoring in data centers helps prevent damage, boost efficiency, and optimize operations for reliable performance!
  86. [86]
    Applications of Hygrometers in the Quality Control and Testing Labs ...
    Pharmaceuticals and Drug Manufacturing: Gao Tek's hygrometers are used to monitor and control humidity levels in pharmaceutical manufacturing environments.
  87. [87]
    Hygrometer And Its Importance in Pharmaceutical Manufacturing
    Hygrometers are important devices in the pharmaceutical world as it measures the relative humidity of the atmosphere, which can affect the products during ...
  88. [88]
    Bosch PRO Deal MT Electrical Testers
    720-day returnsBuy one or more Electrical Testers and choose from a selection of measuring tools.*. Valid for purchases until 31.12.2025. Rewards ...
  89. [89]
    Analog Hygrometer, Round Glass Analog Hygrometer for Cigar ...
    Analog Hygrometer, Round Glass Analog Hygrometer for Cigar Humidors, Accurate, Reliable, and Attractive Look ; Color. gold ; Product Dimensions. 2.25"W x 1.75"H.
  90. [90]
    Analog Hygrometer - Exo Terra
    The analog hygrometer monitors terrarium humidity, essential for reptile/amphibian health, and has an easy-to-read display and is easy to install.
  91. [91]
    Hygrometer Trends 2025: Smart & Digital Growth - Accio
    Oct 5, 2025 · Explore the latest hygrometer trends in 2025, including smart IoT integration, rising demand for digital models, and key market shifts.
  92. [92]
    Hygrometer Market Size, Share, Insights & Forecast 2033
    Rating 4.2 (100) Hygrometer Market size stood at USD 1.2 Billion in 2024 and is forecast to achieve USD 2.5 Billion by 2033, registering a 9.2% CAGR from 2026 to 2033.
  93. [93]
  94. [94]
    [PDF] General guidelines for the on-site calibration of humidity ... - GovInfo
    FORCED AIR PSYCHROMETERS ANDTHE PSYCHROMETRIC CHART. 14. 6.2. DEW POINT DEVICES ... instruments used as standards in the calibration process. Calibration ...
  95. [95]
    [PDF] Guideline DKD-R 5-8 Calibration of hygrometers for the direct ...
    The purpose of this guideline is to define minimum requirements for the reference standard, calibration equipment, calibration procedure and the estimation of ...
  96. [96]
    (PDF) Practical Study of Psychrometer Calibrations - ResearchGate
    Aug 7, 2025 · This paper presents the results of a comparison of psychrometer calibrations performed by the NMIs in Denmark, Slovenia, and Finland.
  97. [97]
    Uncertainty Analysis in Humidity Measurements by the ...
    Feb 14, 2017 · At a fixed dry bulb temperature, an increase in the wet bulb depression increased the error. A new equation for the psychrometer constant was ...
  98. [98]
    [PDF] Equilibrium ReIative Humidity - Saturated SaIt Solutions
    A very convenient method to calibrate humidity sensors is the use of saturated salt solutions. At any temperature, the concentration of a saturated solution is ...
  99. [99]
    [PDF] Maintaining Constant Relative Humidity by Means of Aqueous ...
    4.1 Standard value relative humidity environments are gen- erated using selected aqueous saturated salt solutions. 5. Significance and Use. 5.1 Standard value ...
  100. [100]
    [PDF] Calibration of Hygrometers with the Hybrid Humidity Generator
    Sep 1, 2021 · The HHG employs the two-pressure method by first using the 550 kPa pressure head of the gas source to raise the pressure in the saturator to ...
  101. [101]
    [PDF] Preparation of Primary Standards by Gravimetric Methods - NOAA
    Aug 1, 2019 · Purpose. This document provides the technical procedures for the preparation of primary standards (as compressed gas mixtures) by ...
  102. [102]
    Calibrating Water Permeation Tubes Using Saturator-Based Primary ...
    May 1, 2003 · Here we describe a new calibration service enabling the measurement of PTG permeation rates directly in terms of NIST primary standards of trace ...Missing: PTB protocols
  103. [103]
    Metrological Traceability: Frequently Asked Questions and NIST Policy
    Per the VIM definition, metrological traceability is established through “an unbroken chain of calibrations, each contributing to the measurement uncertainty.” ...
  104. [104]
    [PDF] Humidity Sensors: A Review of Materials and Mechanisms
    We have reviewed humidity sensors based on various materials for both relative and absolute humidity, including ceramic, semiconducting, and polymer ...Missing: 1960s | Show results with:1960s
  105. [105]
    Rotronic Humidity Sensors: Capacitive Polymer Technology
    Contamination by organic or inorganic substances, such as oils or chemical residues, can also alter the sensor properties and cause measurement drift.Missing: hygrometer error
  106. [106]
    A methodology for study of in-service drift of meteorological humidity ...
    May 25, 2017 · Some reports estimate drift at more than 5%rh per year for some sensor types [14]. This is important for the attribution of uncertainty to ...Missing: resistive yearly<|separator|>
  107. [107]
    Ventilation effects on humidity measurements in thermometer screens
    Jan 3, 2019 · Standard RH calculations generally assume a fixed screen psychrometer coefficient, but this is too small during poor ventilation. By ...
  108. [108]
    Common humidity measurement problems and how to avoid them
    Jan 11, 2024 · Use a solar radiation shield. Solar radiation can easily heat sensors by 2°C (4–5°F). To avoid the effects of solar radiation, use a sensor ...
  109. [109]
    [PDF] Comparing the Long-Term Stability and Measurement - MDPI
    Oct 15, 2025 · In this study, a self-made integrated three-in-one microsensor capable of simultaneously measuring airflow velocity, temperature, and humidity ...
  110. [110]
    Sensor Calibration at Scale: Automated Techniques for Millions of ...
    Sep 23, 2025 · Discover automated sensor calibration techniques for millions of IoT devices, from scalability to AI-driven solutions.
  111. [111]
    Real-Time Correction and Long-Term Drift Compensation in MOS ...
    Aug 29, 2025 · In this study, we propose a real-time data error correction and prediction framework for long-term drift compensation in sensor arrays. On one ...
  112. [112]
    [PDF] SKYDEW chilled-mirror hygrometer
    When the chilled mirror hygrometer maintain thin dew/frost layer constantly, the mirror temperature is equal to the dew/frost point temperature in ambient air.
  113. [113]
    A sensitive paper-based chipless RFID sensor for humidity ...
    May 27, 2025 · This paper presents a novel high-sensitivity paper-based humidity sensor consisting of an LC resonant structure. The sensor operates at 2.45 GHz.
  114. [114]
    Humidity Sensor BME280 - Bosch Sensortec
    The BME280 is a humidity sensor especially developed for mobile applications and wearables where size and low power consumption are key design parameters.
  115. [115]
    What's the Purpose of Installing Barometric Sensors in Smartphones? -
    Jun 5, 2025 · Smartphones integrate barometric sensors with GPS, accelerometers, gyroscopes, and other sensors to form multi-sensor data fusion systems. The ...Sensor Fusion In Smartphone... · Packaging Technology And... · Sensor Fusion In Indoor...
  116. [116]
    Machine Learning–Based Calibration and Performance Evaluation ...
    This study uses machine learning to calibrate low-cost air quality sensors, finding that GB and kNN models achieved the highest accuracy.
  117. [117]
    Humidity Sensor Market Size, Share and Industry, 2025 To 2030
    Jan 30, 2025 · Compact digital humidity sensors, based on MEMS technology, allow for accurate and efficient measurement in space-constrained applications. Low ...
  118. [118]
    GDH 1-17 Thermo Hygrometer - Bosch Professional
    720-day returnsIt provides real-time, minimum, and maximum readings of air temperature, relative humidity, dew point, wet bulb temperature, and absolute humidity to ensure ...Missing: app integration
  119. [119]
    Bosch expands its range of measurement technology for ...
    Sep 17, 2025 · With the four new devices – the GDH 1-17 Professional digital thermo-hygrometer and the GMP 1-13 Professional, GMP 2-15 Professional, and GMM 1 ...Missing: app integration