Fact-checked by Grok 2 weeks ago
References
-
[1]
Photoplethysmogram Analysis and Applications: An Integrative ... - NIHMar 1, 2022 · Photoplethysmography (PPG) is a non-invasive method for measuring blood volume changes in a microvascular bed of the skin based on optical ...
-
[2]
Photoplethysmography and its application in clinical physiological ...Photoplethysmography (PPG) is a simple and low-cost optical technique that can be used to detect blood volume changes in the microvascular bed of tissue.
-
[3]
A review on wearable photoplethysmography sensors and their ...Aug 6, 2018 · Photoplethysmography (PPG) is an uncomplicated and inexpensive optical measurement method that is often used for heart rate monitoring purposes.Missing: principles | Show results with:principles
-
[4]
Photoelectric Plethysmography of the Nasal Septum in ManFirst published November 1937. Request permissions. Photoelectric Plethysmography of the Nasal Septum in Man. Alrick B. HertzmanView all authors and ...
-
[5]
Photoelectric Plethysmography of the Fingers and Toes in ManPhotoelectric Plethysmography of the Fingers and Toes in Man · A. B. Hertzman · Published 1 December 1937 · Medicine · Proceedings of the Society for Experimental ...Missing: 1938 | Show results with:1938
-
[6]
DISTINCTION BETWEEN ARTERIAL, VENOUS AND FLOW ...1937 · 1938 · 1939 · 1940 · 1941 · 1942 ... DISTINCTION BETWEEN ARTERIAL, VENOUS AND FLOW COMPONENTS IN PHOTOELECTRIC PLETHYSMOGRAPHY IN MAN. Alrick B. Hertzman, ...
-
[7]
THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED ...The blood supply of various skin areas as estimated by the photoelectric plethysmograph. Published Online:31 Oct 1938.
-
[8]
Tribute to Dr. Takuo Aoyagi, inventor of pulse oximetry - PMCDr. Takuo Aoyagi invented pulse oximetry in 1974. Pulse oximeters are widely used worldwide, most recently making headlines during the COVID-19 pandemic.
-
[9]
pyPPG: a Python toolbox for comprehensive photoplethysmography ...Apr 8, 2024 · ... 1940s (Dillon and Hertzman 1941). It was not until the 1970s that photoplethysmography became widely used as the sensing technology in pulse ...Missing: 1950s | Show results with:1950s
-
[10]
Fitbit - WikipediaDeveloper, Google ; Initial release, 21 March 2014; 11 years ago (2014-03-21).
-
[11]
ISO 80601-2-61:2011 - Medical electrical equipmentISO 80601-2-61:2011 applies to the basic safety and essential performance of pulse oximeter equipment intended for use on humans, hereafter referred to as ME ...Missing: PPG | Show results with:PPG
-
[12]
Photoplethysmography—new applications for an old technologyPhotoplethysmography (PPG) is a noninvasive optical technique from which many physiologic parameters may be derived, as it produces a waveform which correlates ...
-
[13]
The advantages of wearable green reflected photoplethysmographyReflected green light PPG can be useful for pulse rate monitoring because it is less influenced by the tissue and vein region.
-
[14]
Respiration Signals from PhotoplethysmographyThe PPG signal is complex and composed of different parts, each having the potential to provide clinically useful information. The respiratory synchronous part ...Missing: less total
-
[15]
[PDF] Photoplethysmography Signal Processing and SynthesisThis attenuated light intensity is detected by an optical sensor and is recorded as a voltage signal known as the photoplethysmogram (PPG). A raw PPG waveform ...
-
[16]
The minimal sampling frequency of the photoplethysmogram for ...Present study aimed to determine the minimal sampling frequency of the PPG signal, which is sufficient for accurate heart rate variability (HRV) analysis.
-
[17]
14.85 µW Analog Front-End for Photoplethysmography Acquisition ...Jan 26, 2019 · The AFE circuit is very important because it determines the quality of the sensed PPG signal, which affects the accuracy of the monitoring ...
-
[18]
PPG EduKit: An Adjustable Photoplethysmography Evaluation ... - NIHFeb 11, 2022 · The analog front-end is composed of several signal conditioning stages, including a transimpedance amplifier, analog filtering and an inverting ...
-
[19]
AFE4900 data sheet, product information and support | TI.comThe AFE4900 device is an analog front-end (AFE) for synchronized electrocardiogram (ECG), photoplethysmogram (PPG) signal acquisition. The device can also be ...
-
[20]
Peak Detection and HRV Feature Evaluation on ECG and PPG ...The Pan-Tompkins [26] algorithm applies low and high pass filters in order to reduce background noise, such as powerline interference or muscle noise. The ...
- [21]
-
[22]
Non-contact physiological monitoring of preterm infants in the ...Dec 12, 2019 · A pulse oximeter is often attached to the patient's ear, finger or toe (see Fig. 1c) from which a Photoplethysmogram (PPG) signal is ...
-
[23]
Perfusion Changes at the Forehead Measured by ... - PubMed CentralMay 27, 2019 · Forehead PPG signals can be used to measure perfusion changes to reveal venous pooling induced by the positioning of the subject. Placing the ...Missing: temporal | Show results with:temporal
-
[24]
A review of the effect of skin pigmentation on pulse oximeter accuracySignal quality was poorer in a great proportion of patients with dark skin pigmentation than intermediate or light. Bias ± SD (Intermediate): +2.8 ± 5.2%.
-
[25]
Photoplethysmography for the Assessment of Arterial Stiffness - MDPIArterial stiffness can cause haemodynamic, mechanical, and volumetric changes. In aged vessels, the unhealthy vessels become stiff and thicken, becoming ...
-
[26]
Differential Sensitivity of Impedance Plethysmography and ... - bioRxivJun 1, 2025 · More specifically, exposure to cold stress causes a reduction in PPG peak amplitudes due to the narrowing of smaller blood vessels.
-
[27]
Sources of Inaccuracy in Photoplethysmography for Continuous ...Apr 16, 2021 · It was found that relative amplitude of the AC component to the entire signal (AC + DC) increased as LED/photodiode spacing increased from 4 to ...
-
[28]
Motion Artifact Reduction in Wearable Photoplethysmography ... - NIHMar 9, 2020 · In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm.Missing: wander | Show results with:wander
-
[29]
Effects of Contact Pressure in Reflectance Photoplethysmography in ...Dec 16, 2021 · This study explores a controlled in vitro study to investigate the effect of continually applied contact pressure on PPG signals.
-
[30]
Decreased accuracy of pulse oximetry measurements during low ...Jun 30, 2006 · Bias exceeding the ± 3% error limit was more common with a perfusion index less than 0.5 than with a perfusion index of 0.5 or greater (Nellcor: ...Missing: PPG | Show results with:PPG
-
[31]
[PDF] PI-PPG: Motion-Robust and Bias-Reduced Wearable ... - OpenReview... AC signal-to-noise ratio (SNR) were calculated where,. PI = AC/DC * 100. (1). AC SNR = 20×log10(AC/Noise) [dB]. (2). These metrics are critical indicators of ...
-
[32]
Validation of Heart Rate Extracted From Wrist-Based ... - NIHThe OHRM could provide an accurate HR (–5 bpm to 5 bpm and –10% to 10% compared to the ECG-derived HR) during both the surgical and recovery phase when the PPG ...
-
[33]
Photoplethysmogram Analysis and Applications: An Integrative ...This review aims to examine existing research on photoplethysmogram concerning its generation mechanisms, measurement principles, clinical applications, noise ...
-
[34]
Photoplethysmography based atrial fibrillation detection: a reviewJan 10, 2020 · This review is a summary of a body of work on AF detection using PPG. A thorough account of the signal processing, machine learning, and deep learning ...
-
[35]
Pulse Wave Velocity: Methodology, Clinical Applications, and ...Jul 17, 2024 · Hence, continuously measuring PWV makes it possible to estimate blood pressure changes noninvasively, cuff-less, and constantly (beat-to-beat) ...
-
[36]
PPG2ABP: Translating Photoplethysmogram (PPG) Signals to ...A method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals.
-
[37]
Photoplethysmography as a Potential Alternative to ...The results showed a high correlation between ECG-derived and PPG-derived HRV data (R2>0.95). Time-domain parameters, frequency-domain parameters and Poincaré ...
-
[38]
Photoplethysmographic determination of the respiratory rate in ... - NIHJan 21, 2019 · The PPG signal includes respiratory synchronous components, seen as frequency modulation of the heart rate (respiratory sinus arrhythmia), ...Missing: weaning | Show results with:weaning
-
[39]
Empirical mode decomposition for respiratory and heart rate ...The PPG signals were analysed using a 1-min sliding window with 50% overlap. The RR and HR estimation accuracy was assessed using the unnormalized root mean ...
-
[40]
[PDF] Empirical Mode Decomposition for Respiratory and Heart Rate ...We introduce a method based on empirical mode decomposition (EMD) to estimate both respiratory rate. (RR) and heart rate (HR) from the photoplethysmographic ...
-
[41]
Perfusion index: Physical principles, physiological meanings and ...Perfusion index (PI) is derived from PPG signal and represents the ratio of pulsatile on non-pulsatile light absorbance or reflectance of the PPG signal.Review · Abstract · Introduction
-
[42]
Impact of central hypovolemia on photoplethysmographic waveform ...Nov 4, 2011 · Our study sought to explore changes in photoplethysmographic (PPG) waveform param- eters, during lower body negative pressure (LBNP) which ...
-
[43]
Relations between ac-dc components and optical path length in ...Jul 1, 2011 · PPG ac is proportionate to stroke volume, so when PPG dc is increased due to increase in central venous pressure, this increases arterial ...
-
[44]
[PDF] Pleth Variability Index: A Dynamic Measurement to Help Assess ...This was the first study to directly demonstrate the ability of PVI to predict fluid responsiveness in mechanically ventilated patients during general.
-
[45]
Pleth Variability Index Predicts Hypotension During Anesthesia ...Conclusion: Pre-anesthesia PVI can predict a decrease in MAP during anesthesia induction with propofol. Its measurement may be useful to identify high-risk ...
-
[46]
None### Summary on PPG Waveform Amplitude for Monitoring Vasopressor Effects or Hemodynamic Changes in Anesthesia
-
[47]
Accuracy of the Composite Variability Index as a Measure of the ...Aug 6, 2025 · ... (BIS) was developed to assess the hypnotic state during anesthesia. ... autonomic nervous system responses, as measured by PPG. Clinical ...
-
[48]
None### Summary: Peripheral Perfusion Index (PPI) as an Early Predictor for Central Hypovolemia
-
[49]
An open-source remote heart rate imaging method with practical ...Analysis. Webcam-based rPPG relies on a series of image-processing steps to extract blood pulsation from the recorded videos and to determine the heart's ...Missing: magnification | Show results with:magnification
-
[50]
Non-contact, automated cardiac pulse measurements using video ...May 10, 2010 · This is the first demonstration of a low-cost accurate video-based method for contact-free heart rate measurements that is automated, motion- ...Missing: et 2011
- [51]
-
[52]
Effectiveness of Remote PPG Construction Methods - NIHSep 20, 2022 · The best performing rPPG methods in all categories were the POS, LGI, and OMI methods; each performed well in all activities.Missing: compensation | Show results with:compensation
-
[53]
[PDF] Robust Remote Heart Rate Estimation from Face Utilizing Spatial ...From the results we can see that most videos (80%) are predicted with an error less than 5 bpm, while the percentage of Niu et al. [13] is 76%. These.
-
[54]
[PDF] An Assessment of Algorithms to Estimate Respiratory Rate From the ...The use of the algorithms designed for contact PPG on remote. PPG signals can lead to respiratory rate estimations with a mean absolute error below 3 breaths ...
-
[55]
[PDF] DEN180042.pdf - accessdata.fda.govThis means the feature cannot detect all instances of AFib, and people with AFib may not get a notification. Apple Watch may be unable to collect data when ...
-
[56]
[PDF] Wearable Photoplethysmography Devices - Peter CharltonWearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram (PPG) signal, an optical measure of the arterial pulse wave which is ...
-
[57]
(PDF) Wearable Upper Arm SpO 2 Sensor for Wellness MonitoringWhen re-training the algorithm from our first iteration, the multiwavelength PPG sensor showed an SpO2 RMSE of 2.61% with a 7-second average analysis for 25 ...
-
[58]
An ML-Based Approach to Reconstruct Heart Rate from PPG in ...In the literature, several works present solutions for the removal of motion artifacts in the PPG signal. ... precision of 98% and a recall of 85%.
-
[59]
[PDF] The New Way to Extract Health Data Is Software-based - Binah.aiBinah.ai's award winning Health Data Platform offers healthcare providers an unparalleled advantage by transforming smartphones, tablets and laptops into health.
-
[60]
Remote patient monitoring: a comprehensive studyOct 26, 2017 · It has been discussed that a dedicated channel for medical data with 5th Generation (5G) mobile systems can further improve 24 × 7 monitoring ...<|separator|>
-
[61]
Wearable textile sensors for continuous glucose monitoringApr 1, 2025 · (c) PPG smart sock prototype as a proof-of-concept design for wearable health monitoring from the foot (Ferreira et al., 2023). (d) ...
-
[62]
Cuff-Less Blood Pressure Prediction from ECG and PPG Signals ...Mar 4, 2022 · This research proposes an algorithm to preprocess photoplethysmography (PPG) and electrocardiogram (ECG) signals and apply the processed signals to the context ...
-
[63]
Whoop says FDA is 'overstepping' with blood pressure feature warningJul 15, 2025 · Whoop has previously received FDA clearance for its ECG feature, which is used to record and analyze a heart's electrical activity to detect ...Missing: 2021 PPG Class II
-
[64]
Motion Artifact Removal Techniques for Wearable EEG and PPG ...To get a clean PPG signal, a contaminated PPG signal is preprocessed such as bandpass filtering and baseline drift removal. Furthermore, reference features of ...Missing: wander | Show results with:wander
-
[65]
An Analytical Model of Motion Artifacts in a Measured Arterial Pulse ...In this paper, an analytical model of MA in a measured pulse signal by an accelerometer and a PPG sensor is presented. MA causes baseline drift and TVSPs ...
-
[66]
A Real-Time PPG Peak Detection Method for Accurate ... - NIHCertainly, significant heart rate estimation error occurs when a peak detection algorithm that is designed for basal heart rate NSR is applied to AF with RVR.
-
[67]
An autocorrelation modeling method for oxygen saturation ...Meanwhile, the new method showed a good performance for the oxygen saturation measurement under the condition of lower perfusion (PI = 0.1%).Conclusions The new ...
-
[68]
Development of a magnetic-resonance-compatible ...The purpose of the present study was to develop a magnetic resonance (MR) compatible photoplethysmograph. (PPG) system that can measure the raw PPG signal ...<|control11|><|separator|>
-
[69]
Impact of the PPG Sampling Rate in the Pulse Rate Variability ...The PPG sampling rate has been reduced by decimation, obtaining signals at 500 Hz, 250 Hz, 125 Hz, 100 Hz, 50 Hz and 25 Hz. Five fiducial points were computed: ...
-
[70]
(PDF) Pulse Oximetry with Two Infrared Wavelengths without ...Oct 22, 2025 · Errors in SpO2 because of variability in path-lengths difference ... constant is significant—about 15% [15]. By using two nearby ...<|separator|>
-
[71]
NoneNothing is retrieved...<|separator|>
-
[72]
[PDF] Adaptive Cancellation of Motion Artifact in Wearable BiosensorsA Least Mean Square (LMS) adaptive noise canceler is then designed and validated using our synthetic noise generator. The analysis and results on proposed ...
-
[73]
(PDF) Motion Artifact Reduction from PPG Signals During Intense ...This paper proposes an efficient method based on a reference generation using singular value decomposition and then multistage application of filtered X-LMS ...
-
[74]
A Photoplethysmography and Motion Sensor Fusion Biometric ...Our evaluations confirm the effectiveness of proposed siamese network with sensor fusion with an average accuracy of 95% and 12% false rejection rate at the 1% ...Missing: multi- IMU
-
[75]
Motion artifact removal from photoplethysmographic signals by ...Apr 24, 2014 · This paper presents a new method which combines the cICA algorithm and adaptive filter to extract the underlying PPG signals from the MA contaminated PPG ...
-
[76]
[PDF] Personalized anomaly detection in PPG data using representation ...Mar 20, 2024 · Our results demonstrate significant improvements: for movement detection, in the generalized scenario, AUCs improved from barely. 0.5 to above ...
-
[77]
[PDF] Perfusion Assessment via Local Remote Photoplethysmography ...This paper presents an approach to assess the perfusion of visible human tissue from RGB video files. We propose metrics derived from remote ...
-
[78]
IEC 63203-402-3:2024Jan 9, 2024 · IEC 63203-402-3:2024 specifies terms, a measurement protocol, and a test to evaluate the accuracy of wearables that measure heart rate with ...Missing: draft | Show results with:draft
-
[79]
High-Detectivity Organic Photodetector with InP Quantum Dots ... - NIHAug 13, 2025 · In practical PPG measurements, the SNR improved from 15 to 19 dB, leading to a notable enhancement in the pulse waveform clarity. The ...
-
[80]
Applying multimodal AI to physiological waveforms improves genetic ...(2) We observed that M-REGLE improved genomics discovery over existing methods for 12-lead ECG dataset and ECG lead I + PPG dataset for three metrics: Number of ...