Fact-checked by Grok 2 weeks ago

Plenum chamber

A plenum chamber is a pressurized containing a gas or , typically air, at positive relative to its surroundings, designed to equalize and facilitate even distribution of the for various purposes. In and , it serves as a compartment that connects to ducts or inlets, forming part of air distribution or flow control systems to ensure uniform and prevent irregularities such as stalls or . This fundamental role makes plenum chambers essential in applications requiring precise management, where they act as intermediaries between sources of pressurized and downstream components. In HVAC systems, plenum chambers function as air-handling compartments to which one or more ducts are connected, enabling the collection, conditioning, and distribution of environmental air throughout buildings while maintaining consistent levels. They are often positioned above suspended ceilings or under floors, serving as return air spaces or supply plenums to optimize efficiency and comply with standards like those from NFPA. In , particularly in intake manifolds of internal combustion engines, the plenum chamber collects and balances incoming air from the throttle body before directing it to cylinders, improving and engine performance. Within contexts, such as wind tunnels and test facilities, plenum chambers isolate porous walls or inlets from , allowing controlled suction or supply of air to generate uniform high-velocity flows for testing components. For instance, in NASA's , inlet plenum chambers supply conditioned to test inlets, incorporating features like screens and to straighten flow and reduce velocity variations from up to 100 m/s to 10-15 m/s. These chambers may also support advanced functions, such as in bypass flows for augmentation in gas turbines, potentially doubling output in certain designs. Overall, the design of plenum chambers—often featuring baffles, dividers, or variable compartments—adapts to specific operational needs, ensuring reliability across diverse high-stakes environments.

Overview

Definition

A plenum chamber is a pressurized or compartment containing a , typically air or gas, maintained at positive relative to the surrounding . This design ensures that the internal exceeds ambient levels, creating a stable for management. The primary function of a plenum chamber is to equalize and distribute evenly across multiple outlets or surfaces, thereby promoting uniform and minimizing or uneven delivery of the . By building up static within the chamber, it facilitates consistent discharge rates, which is essential for applications requiring precise control. Key characteristics of a plenum chamber include its sealed or semi-sealed structure, featuring one or more inlets for input and multiple outlets, such as ducts, for . It operates on the principle of accumulation, often integrating components like baffles or screens to further homogenize before exit. Unlike a standard , which focuses on to withstand internal pressures, a plenum chamber prioritizes dynamic equalization to support even dispersion across connected systems.

Etymology and History

The term "plenum" derives from the Latin plēnum, the neuter form of plēnus meaning "full" or "complete," originally referring to a filled with as opposed to a . It entered English technical usage in the 1670s, initially denoting a condition of fullness or abundance in philosophical and scientific contexts, such as discussions of and by natural philosophers like . The specific phrase "plenum chamber" first appeared in engineering literature in 1908, attributed to Alfred G. King in his work on heating and ventilation systems, where it described a pressurized for distributing heated air evenly. Plenum chambers emerged in the early amid advancements in and the rise of internal combustion engines, serving as rudimentary equalizers to ensure uniform air or distribution. Influenced by 19th-century pneumatic theories, such as those explored in early experiments, no major for plenum chambers predate 1900, but their principles drew from foundational work on pressurized air systems. For example, a by F.W. Schroeder described a plenum chamber for air cushion boats. Over time, plenum chambers evolved from simple enclosures in early engines—often basic boxes for balancing—to sophisticated components in modern technologies.

Design and Principles

Basic Components and Design

A chamber typically consists of several core components designed to facilitate controlled entry, , and exit while maintaining internal . Inlet ports serve as entry points for fluids, often sourced from compressors or ducts, and may include settling tanks or regulators to ensure stable inflow. Internal baffles or diffusers, such as turning vanes or structures, direct and uniformize the flow, reducing and distortions. Outlet manifolds, including convergent nozzles or slots, enable even to downstream systems, while relief valves provide safety by venting excess to prevent over-pressurization. Design considerations emphasize material selection tailored to operational demands, such as lightweight alloys like aluminum or for applications to minimize weight, or corrosion-resistant for industrial environments exposed to harsh fluids. Volume sizing is determined by required flow rates, with compact designs featuring cross-sectional areas around 144 square inches for targeted air delivery, ensuring the chamber provides sufficient for stabilization without excessive loss. Sealing mechanisms, including welded joints or , are critical to maintain positive and prevent leaks that could compromise efficiency. Variations in plenum design include rigid constructions using or for structural integrity in fixed installations, and flexible options like fabric or collapsible materials for adaptable setups in space-constrained or temporary applications. with sensors, such as monitors, allows real-time oversight to sustain optimal conditions. ranges from small volumes of approximately 25 cubic inches in high-pressure systems to larger enclosures supporting HVAC distributions over hundreds of cubic meters, accommodating diverse flow needs. These designs often incorporate optimized geometries, like trapezoidal diffusers, to minimize drops and enhance overall . Pressurized plenum chambers may be subject to pressure vessel codes such as ASME Boiler and Code Section VIII when they meet the criteria for pressure vessels, governing fabrication, inspection, and safety features like relief valves to ensure compliance in high-stakes uses. This structural approach supports the chamber's role in pressure equalization for uniform downstream flow.

Operational Principles

A plenum chamber operates by confining incoming within a larger volume, allowing from the to convert into uniform that distributes evenly to multiple outlets, thereby minimizing variations across the discharge points. This pressure equalization process ensures that irregular supply flows are smoothed out, providing consistent delivery to downstream components such as diffusers or nozzles. The underlying rely on , which states that along a streamline, the total energy remains constant: P + \frac{1}{2} \rho v^2 + \rho g h = \constant, where P is , \rho is fluid density, v is , g is , and h is elevation. In a plenum chamber, as the fluid enters and expands into the larger space, v decreases significantly, causing P to rise and equalize throughout the chamber while changes (\rho g h) are typically negligible in horizontal setups. This deceleration also promotes , where turbulent inlet flow slows and spreads uniformly, often aided by internal features that break up eddies and promote laminar-like distribution at outlets. Efficiency in plenum operation depends on geometric factors like the (chamber length to width), which influences recirculation zones; a higher (e.g., greater than 5:1) helps minimize eddies by allowing sufficient diffusion length, reducing uneven gradients. drops within the chamber can be estimated using the Darcy-Weisbach equation: \Delta P = f \frac{L}{D} \frac{\rho v^2}{2}, where f is the (dependent on and surface roughness), L is the effective length, D is the , \rho is , and v is ; this accounts for frictional losses along walls, particularly in chambers where flow paths approximate duct-like behavior. Despite these principles, limitations arise, such as potential hotspots from uneven flow if internal baffles are poorly positioned, leading to localized high-velocity streams that bypass equalization and cause or inconsistencies at outlets. In high-flow scenarios, energy losses due to become prominent, as viscous in turbulent mixing dissipates into , reducing overall in compact designs. Modern designs often employ (CFD) simulations to optimize flow patterns and mitigate these issues.

Applications

In Automotive Engineering

In internal combustion engines, the plenum chamber functions as the central reservoir within the intake manifold, collecting air from the throttle body and distributing it evenly to the individual runners leading to each . This equalization of ensures a consistent air-fuel mixture across all , which enhances efficiency by maintaining optimal and reducing variations in filling. By promoting smoother operation and better fuel , the plenum contributes to increased power output and overall engine performance. In forced-induction systems such as those using turbochargers or superchargers, the plenum chamber stores , acting as a to smooth out pulsations from the and deliver consistent pressure to the . This effect prevents pressure fluctuations that could disrupt during intake valve cycles, ensuring steady manifold pressure for improved response and power delivery. Typical levels in automotive applications range up to 2-3 , allowing for significant enhancements in and horsepower without excessive . Historically, chambers were incorporated into setups on classic motorcycles from the 1950s to 1960s, such as models from including the , to balance intake pressures and optimize air distribution for racing applications. These designs helped mitigate uneven airflow from multiple , enhancing throttle response and high-RPM performance in single-cylinder engines tuned for events like the Isle of Man TT. Modern advancements include variable-length intake plenums, as seen in engines equipped with the DISA (Differential Air Intake) system, which adjusts runner length via a flap to optimize across different RPM ranges. At low speeds, longer runners improve low-end by leveraging inertial effects, while shorter runners at high speeds boost top-end power; this configuration can yield overall power gains of 5-10% through broader curves and enhanced .

In Aerospace and Marine Engineering

In hovercraft, the plenum chamber serves as a central reservoir that distributes pressurized air to the underside of the craft, where it is contained by a flexible skirt to form an air cushion supporting the vehicle above the surface and enabling low-friction travel over land, water, or ice. This design equalizes pressure across the cushion area, minimizing variations in lift and allowing operation on uneven or wavy surfaces, such as in amphibious vehicles where it prevents instability from surface undulations. Typical operating pressures in the plenum chamber range from 1 to 3 kPa above atmospheric, applied over large cushion areas to achieve the required lift with efficient airflow. For instance, the SR.N4 hovercraft, developed in the 1960s by the British Hovercraft Corporation, utilized this system with a cushion pressure of approximately 2.6 kPa to support its 193-tonne mass while cruising at over 60 knots (111 km/h). In applications, plenum chambers are integral to systems for distributing compressor , which is extracted from intermediate compressor stages to supply various aircraft functions while minimizing flow losses through even pressure equalization in the annular chamber. They also facilitate by routing conditioned into the cabin environment via dedicated plenums, maintaining a comfortable differential during high-altitude flight. In vertical takeoff and landing () aircraft like the , plenum chambers enable augmentation through plenum chamber burning (PCB), where fuel is injected into the engine's bypass airflow within the chamber to significantly increase for enhanced short takeoff performance and vectoring via swiveling nozzles. This PCB approach was tested on modified engines in the 1980s but not adopted in production due to stability challenges during operation. The air cushion generated by plenum chambers in these systems significantly reduces compared to traditional wheeled or hull-based alternatives by eliminating direct surface contact. This efficiency supports operational speeds of 60 knots or more in marine and amphibious environments, as demonstrated by the SR.N4's service in cross-Channel operations.

In Building and HVAC Systems

In building (HVAC) systems, plenum chambers function as central distribution boxes, commonly installed above suspended ceilings or beneath raised floors, to collect and evenly disperse conditioned air from the main supply trunk into branch ducts. This configuration promotes uniform airflow throughout occupied spaces, helping maintain consistent room temperatures and preventing hot or cold spots. By acting as an intermediary between the and terminal devices like diffusers or grilles, plenums facilitate balanced and reduction, enhancing overall system performance. Design considerations for plenum spaces in buildings emphasize functionality and safety, with return air plenums dedicated to recirculating exhausted air back to the HVAC unit for reconditioning. These spaces must incorporate fire-rated materials to comply with standards such as NFPA 90A, which mandates that materials within plenums be noncombustible or exhibit a flame spread index of no more than 25 and a of no more than 50 to minimize propagation risks. Plenum chambers rely on controlled buildup to ensure smooth air transition, aligning with broader operational principles of HVAC . Construction often involves or insulated panels sealed to prevent leaks, with sizing based on capacity to handle substantial portions—typically equivalent to 10-50% of total for optimal . The integration of plenum chambers yields key benefits, including through airflow dampening and minimization, as well as elimination of drafts via even delivery that avoids high-velocity jets. These features contribute to occupant comfort while supporting ; balanced distribution can yield 15-20% gains in system performance by lowering fan energy demands and optimizing . In modern applications, such as data centers, underfloor plenum chambers supply cooled air directly to server racks, maintaining positive —typically around 0.02 inches of —to exclude and contaminants, thereby enhancing reliability and cooling precision.

In Nuclear and Industrial Processes

In designs, chambers play a crucial role in managing distribution around fuel rods to ensure uniform and prevent hotspots. In pressurized water reactors (PWRs), the lower collects incoming from the inlet nozzles and directs it evenly through via distributors, maintaining hydraulic stability under high-pressure conditions. This design minimizes maldistribution, which could otherwise lead to thermal-mechanical stresses on fuel assemblies. In sodium-cooled fast breeder reactors (s), upper chambers above fuel subassemblies equalize sodium flow and temperature, supporting stable thermal-hydraulic performance in the and hot pool. These plenums enhance safety by facilitating neutron leakage during partial sodium drainage, providing a negative reactivity (e.g., -0.5 β_eff) to mitigate loss-of-flow accidents and reduce meltdown risks. Operating at near-atmospheric , SFR plenums integrate with argon cover-gas systems to prevent sodium oxidation and include safety vessels for leakage , ensuring immersion. Plenum chambers in industrial processes, such as chemical plants and furnaces, distribute gases uniformly in fluidized bed reactors to optimize reaction efficiency and control environments. In direct reduction of iron (DRI) processes, inlet plenums ensure even gas flow across the bed, reducing pressure drops and enhancing process uniformity. To prevent explosions in handling combustible materials, these chambers maintain inert atmospheres by introducing nitrogen or other non-reactive gases, displacing oxygen below explosive limits. Safety features of plenum chambers in these high-hazard settings include high-pressure tolerance, with designs in PWRs accommodating up to approximately 155 bar to match reactor vessel operating conditions. Radiation shielding is integrated through the enclosing , which surrounds the plenum and provides multi-layered protection against and gamma radiation. In SFRs, plenums contribute to passive safety by promoting natural for removal. Challenges in these applications include from radioactive or aggressive fluids, such as sodium in SFRs, which demands robust materials like oxide-dispersion-strengthened (ODS) steels to withstand high temperatures up to 550°C and chemical reactivity. Designs must also comply with (IAEA) standards for reactor coolant systems, emphasizing integrity, leak-tightness, and defense-in-depth to protect against operational transients and accidents.

Other Specialized Uses

Plenum chambers find application in outdoor enclosures for and housings, where they facilitate to equalize internal air against external conditions, thereby preventing and ensuring equipment longevity in IP-rated cabinets. These systems, incorporating baffles and air transfer mechanisms, have been integrated into protective enclosures since the early to maintain stable internal environments for displays exposed to varying atmospheric pressures and temperatures. In medical and laboratory equipment, plenum chambers are employed in cleanrooms to distribute laminar evenly across workspaces, minimizing particle contamination through ceiling-mounted or ULPA filtration units that direct filtered air into the plenum for uniform downward flow. This setup achieves high levels of air by guiding contaminating particles into exhaust plenums, supporting applications in pharmaceutical and . In medical ventilators, plenum chambers serve as inserts in interfaces to ensure even distribution of oxygen and respiratory gases, reducing turbulence and improving delivery efficiency during . Emerging technologies leverage plenum chambers for precise environmental control in additive manufacturing, particularly in powder bed fusion processes where they enclose the laser's within an inert gas atmosphere, such as , to extract fumes and maintain oxygen levels below 100 ppm for oxidation-free metal printing. In wind tunnels, upstream plenum chambers condition airflow by slowing and equalizing pressure from high-speed inlets, producing uniform test section velocities with intensities as low as 0.5%, essential for aerodynamic testing of models like components. This design mitigates backflows and pressure gradients, enabling reliable simulation of free-stream conditions. Miscellaneous uses include acoustic plenums in soundproofing systems, which function as pressure chambers lined with porous absorptive materials to attenuate low-frequency noise by converting sound wave into through viscous and losses. These reactive and dissipative elements, often integrated into HVAC ducts or enclosures, can achieve insertion losses of up to 20 dB in the 50-200 Hz range, enhancing in buildings without significantly impeding . Perforated panels within the further optimize performance by altering vortex structures and reducing peak levels.

References

  1. [1]
    Plenum Chamber - an overview | ScienceDirect Topics
    A plenum chamber is defined as a component in a propulsion system where fuel is burned in the bypass flow to enhance thrust, potentially doubling the thrust ...
  2. [2]
    [PDF] MODEL INVESTIGATION OF INLET PLENUM FLOW ...
    One-twentieth-scale models of the inlet plenum chamber of the two test chambers were used in the investigation to minimize time and cost.
  3. [3]
    [PDF] state building code interpretation no. i-10-04 - CT.gov
    May 25, 2020 · This is because the NFPA definition of plenum is a compartment or chamber to which one or more ducts are connected that forms part of the air ...
  4. [4]
    [PDF] FROM: KSI/Scientific & Technical Information Attn
    Jul 13, 1973 · plenum chamber includes means for reducing the pres- sure in said chamber on the up stream side of said di- vider wall. ' 7. The apparatus ...
  5. [5]
  6. [6]
    plenum, n. & adj. meanings, etymology and more
    OED's earliest evidence for plenum is from 1674, in the writing of Robert Boyle, natural philosopher. plenum is a borrowing from Latin. Etymons: Latin plēnum, ...
  7. [7]
    Plenum - Etymology, Origin & Meaning
    Originating in the 1670s from Latin plenum, meaning "full space," the word denotes fullness or abundance, including physical space and complete assemblies.Missing: chamber | Show results with:chamber
  8. [8]
    plenum chamber, n. meanings, etymology and more
    The earliest known use of the noun plenum chamber is in the 1900s. OED's earliest evidence for plenum chamber is from 1908, in the writing of A. G. King. Nearby ...
  9. [9]
    [PDF] Aircraft Engines - Federal Aviation Administration
    parts of the plenum chamber are the auxiliary air-intake doors ... Another very important requirement in the construction of combustion chambers is providing the ...
  10. [10]
    Supercharger Development in the U.S. During the Inter-War Period
    1. British supercharger drive, circa 1920. Engine oil provided lubrication on this example. German designs often used a separate reservoir and dedicated oil ...Missing: plenum chamber
  11. [11]
    Plenum chamber | mechanics - Britannica
    Oct 24, 2025 · principle, in which air is pumped directly into a cavity beneath the vessel, because of the difficulty in containing the cushion.Missing: mechanical engineering
  12. [12]
    2 Nuclear Thermal Propulsion - The National Academies Press
    A nuclear thermal propulsion (NTP) system uses a nuclear reactor to heat propellant, replacing the combustion chamber in a chemical system.<|control11|><|separator|>
  13. [13]
    [PDF] Design of a Compact Plenum Chamber for Supply of Air to an ... - DTIC
    This report describes the design of a compact plenum chamber the function of which Is to receive air from a rectangular duct and deliver It to an annular space ...
  14. [14]
    ISO 4 Cleanroom Plenum Design: Efficiency & Compliance | ACH
    In this article, we will explore the key factors and considerations in designing an ISO 4 cleanroom plenum for an efficient and effective cleanroom environment.Proper Airflow And... · Effective Filtration And... · Pressure Control And...
  15. [15]
  16. [16]
    Haskel Plenum Chambers - Fluid Process Control
    The Haskel 17843 Plenum Chamber has a volume of 25 cu.in. and is rated for a working pressure of 1400 psig. It has 1/4": FNPT connections.
  17. [17]
    Uniformity of Supply Air in the Plenum for Under-Floor Air ... - MDPI
    ... dynamic pressure to static pressure. The pressure distribution and flow ... Velocity and Static Pressure Field of Plenum Chamber. For different cases ...<|control11|><|separator|>
  18. [18]
    Flow characteristics and structural parametric optimisation design of ...
    Sep 1, 2021 · Plenum chambers are in essence large rectangular enclosures with an inlet and one or more outlets, usually installed between a fan and main ...
  19. [19]
    Ground Effect Vehicles – Introduction to Aerospace Flight Vehicles
    Plenum Discharge Theory. The radial fluid discharge from a plenum chamber forms one mathematical foundation for analyzing the hovercraft. The figure below ...
  20. [20]
  21. [21]
    Visualization experiment and flow homogenization optimization of ...
    Apr 1, 2023 · Plenum chambers are commonly used to provide flow homogenization in ventilation and air conditioning systems. To reduce energy consumption ...Missing: equalization | Show results with:equalization
  22. [22]
    Air Flow, Air Systems, Pressure, and Fan Performance - CaptiveAire
    Duct air moves according to three fundamental laws of physics: conservation of mass, conservation of energy, and conservation of momentum.
  23. [23]
    Effect of Plenum Chamber Obstructions on Data Center Performance
    Aug 9, 2025 · It was found that obstructions in the plenum chamber can cause an increase in the occurrence of hot spots. ... Experimental methods to ...
  24. [24]
    Effects of Geometry of Plenum Chamber on Losses in the Bleed ...
    Aug 2, 2022 · 3.1.​​ The recirculation zone—which occupies approximately half of the axial width of the slot—is generated by a portion of the low-speed flow ...Missing: aspect | Show results with:aspect
  25. [25]
    What Is an Intake Manifold?
    ### Role of the Plenum in Intake Manifolds
  26. [26]
    The Impact of Intake Manifold on Engine Efficiency - Mtn. View Ford
    How Does It Work? Air enters the intake manifold through the throttle body, passes into a central chamber (called the plenum), and is routed to individual ...Missing: internal | Show results with:internal
  27. [27]
    Restrictors And Plenums And Sometimes Turbos - DesignJudges.com
    Nov 3, 2020 · The restrictor limits the amount of air an engine can use. The intake plenum smooths out the intake pulses, and makes it possible for other ...
  28. [28]
    The Basics of Turbocharging and Supercharging - Ate Up With Motor
    Apr 8, 2008 · Automotive superchargers for street use typically produce a maximum boost pressures between 5 and 15 psi (0.33 to 1.0 bars), providing a ...
  29. [29]
    A Look Inside the Manx Engine | Cycle World | AUGUST 1965
    A LOOK INSIDE THE MANX ENGINE. GORDON JENNINGS. IN A SENSE, the design and development of Norton's famous "Manx" engine is a study in human personalities.
  30. [30]
    Crankcase Breathing - Norton Owners Club
    This system does work better with an active vacuum from the intake manifold. ... Design details included a plenum chamber to even out the pressure pulses coming ...Missing: 1950s | Show results with:1950s
  31. [31]
    BMW - The Magic DISA Valve - Atlantic Motorcar Center
    Apr 26, 2012 · The DISA valve is located in the inlet plenum chamber and controls the variable length intake manifold giving better torque at low revs by closing.<|separator|>
  32. [32]
    M50 Intake on Modified E46 (worth it?)
    Jul 10, 2021 · For a daily driver, I would keep a functioning DISA manifold. Yes, you might gain 5- 10 horsepowers, but you'll lose torques down lower, AND ...M50 manifold conversion - E46 Fanatics ForumQuestion about Tuning with DISA and Without | E46 Fanatics ForumMore results from www.e46fanatics.com
  33. [33]
    Air-cushion machine - Hovercraft, Propulsion, Design - Britannica
    Sep 27, 2025 · Early craft had a hole located near the centre of the buoyancy raft through which air was fed to the plenum chamber beneath, but the development ...
  34. [34]
    M.1715 Floating on air - The Contact Patch
    Most hovercraft today are based on the principle of the plenum chamber. But ... Bernoulli's Law) makes the pressure rise [30]. But when the vessel ...
  35. [35]
    The Princess Anne - Museum Ships
    The first design was 40 metres (131 ft) long, weighed 190 long tons (193 t), was capable of 83 knots (154 km/h) and could cruise at over 60 knots (111 km/h).
  36. [36]
    Harrier Test Bed on the move - Aviation Heritage UK
    Jan 29, 2020 · The unusual aircraft was especially built in the early 1980s to test a Rolls-Royce Pegasus turbofan engine modified with plenum chamber burning ...
  37. [37]
    Harrier PCB tests | Key Aero
    PCB (Plenum Chamber Burning) tests being carried out on the Pegasus powerplant in order to provide the Harrier with a form of re-heat.
  38. [38]
    [PDF] Design & Development of Air Cushion Vehicle - ijirset
    Hovercraft started as an experimental design to reduce the drag that was placed on boats and ships as they ploughed through water. The first recorded design ...
  39. [39]
    Largest hovercraft, civillian - Guinness World Records
    ... maximum speed in excess of the scheduled permitted cross-Channel operating speed of 65 knots (120 km/h or 75 mph). Cross-channel services ceased in December ...Missing: top | Show results with:top
  40. [40]
    What is a plenum box and how does it work? - Goveco
    In typical installations, the plenum box is connected on one side to a flexible duct or rigid duct line, and on the other side to the air outlet. It serves ...
  41. [41]
    Understanding the Role of a Plenum in Your HVAC System - Houk AC
    Mar 20, 2023 · A plenum is essentially the “traffic manager” for air in your HVAC system. It's a duct or chamber that gathers conditioned air and sends it all ...
  42. [42]
  43. [43]
    Materials in HVAC Plenums - Warren Forensics
    Aug 22, 2024 · Materials within plenums shall be noncombustible or shall be listed and labeled as having a flame spread index of not more than 25 and a smoke developed index ...
  44. [44]
    What Is a Plenum in HVAC? | Key Functions & Benefits | RHCC
    By acting as a buffer between the HVAC unit and the ducts, plenums help reduce vibrations and dampen noise, leading to a quieter system operation. This ...
  45. [45]
    The Wonderful World of Plenum HVAC - Smart Service software
    Rating 4.8 (250) The plenum is a vital part of any HVAC system. It is the section of the duct work between the furnace and the branching off of the main trunk line.
  46. [46]
    None
    Summary of each segment:
  47. [47]
    Coolant flow field in a real geometry of PWR downcomer and lower ...
    The present work analyzes the flow distribution in the downcomer and lower plenum of Korean standard nuclear power plants (KSNPs). The real geometry is used ...
  48. [48]
    Experimental Research of Flow Distribution at Reactor Core Inlet of ...
    Jun 8, 2022 · The flow distributor with numerous small holes in the lower plenum will break a large vortex and make flow uniform. Then the water flows through ...
  49. [49]
    [PDF] 4th Generation sodium-cooled fast reactors / The Astrid ... - CEA
    In the event of drained situation following partial loss of sodium in the core, this plenum will allow neutron leakage out of the core. The innovation of ...
  50. [50]
    [PDF] Nitrogen inerting to prevent combustible dust explosions - Air Products
    Unlike mechanical explosion control systems, using inert gas systems for combustible dust handling can prevent an explosion before it starts by removing the ...
  51. [51]
    [PDF] IAEA Safety Standards Design of the Reactor Coolant System and ...
    This series covers nuclear safety, radiation safety, transport safety and waste safety. The publication categories in the series are Safety Fundamentals,.
  52. [52]
    Outdoor Digital Signage Enclosure: What's a Plenum Chamber?
    A plenum chamber is simply a type of ventilation or air transfer system. It ensures, through the use of baffles, that air pressure is equalised for the ...Missing: engineering | Show results with:engineering
  53. [53]
  54. [54]
    Principle of Cleanroom - PMC - PubMed Central - NIH
    ... plenum chamber at the ceiling should occupy a certain proportion of the total area. ... The amount of airflow entering the room by the opening of door and ...
  55. [55]
    Methods of Cleanroom Air Flow Calibration - Tips for Balancing and ...
    The fans driving laminar flow are effective in controlling speed and direction of clean, filtered air, forcing contaminating particles into plenums for either ...
  56. [56]
    EP4420707A3 - Plenum chamber insert for patient interface
    ... respiratory system of patients by gas treatment, e.g. ventilators; Tracheal tubes. A61M16/20 Valves specially adapted to medical respiratory devices. A61M16 ...
  57. [57]
    A large format DMLM system using a continuously rotating powder bed
    A laser-safe enclosure provides an inert gas environment for the process. A local gas plenum encloses the field of view of the laser and serves to extract ...
  58. [58]
    Wind tunnel flow generation section - NASA Technical Reports Server
    A plenum chamber is associated with the exterior side of each of such porous walls to separate the same from ambient pressure.
  59. [59]
    Development of novel low-speed open jet wind tunnel equipped ...
    The use of a plenum chamber is advantageous as it reduces the effects of variation in atmospheric pressure inside the test section, reduces backflows from rigid ...
  60. [60]
    Noise Reduction of a Fan and Air Duct by Using a Plenum Chamber ...
    Jan 17, 2011 · A sound-absorbing plenum is an economical device for achieving significant attenuation. Plenum performance can be increased by increasing the ...
  61. [61]
  62. [62]
    Optimization and analysis of the acoustic and resistance ...
    This includes: (1) converting part of the dynamic pressure into static pressure so that the air flow can be transported farther; (2) making the air volume ...