TRIAC

A TRIAC (Triode for ) is a three-terminal that functions as a bidirectional switch, capable of conducting current in either direction when triggered by a signal, making it ideal for controlling in circuits. It belongs to the family and is structurally equivalent to two silicon-controlled rectifiers (SCRs) connected in inverse parallel with a shared , allowing it to handle both positive and negative half-cycles of an without needing separate components for each direction. The device features two main terminals—MT1 (Main Terminal 1) and MT2 (Main Terminal 2)—along with the (G), and its four-layer PNPN construction enables latching conduction once triggered, where it remains on until the current falls below the holding current (I_H) at the end of each cycle. TRIACs operate in four triggering modes (quadrants) based on the polarity of the voltage between MT2 and MT1 relative to the pulse, with sensitivity varying across modes—typically most sensitive in quadrants I and III, and least sensitive in IV. Triggering requires a short pulse (around 35 microseconds) exceeding the gate trigger current (I_GT), after which the device blocks current until the next cycle unless a is used to prevent false triggering from voltage transients. Key characteristics include high surge current capability (up to several times the rated current, e.g., 50 A for some models), blocking voltages from 600 V to 1200 V, and operation up to 150°C in advanced designs, ensuring reliability in demanding environments. Widely used in applications requiring precise AC power regulation, TRIACs enable phase control for dimming lights, adjusting motor speeds, and switching heaters, often paired with diacs or microcontrollers for timing. They offer advantages over mechanical relays, such as faster switching, no arcing, and longer lifespan, though they require careful gate drive design to avoid issues like rate-of-rise (dv/dt) failures. In modern electronics, TRIACs are integral to , industrial controls, and consumer appliances, with manufacturers producing variants rated from 0.8 A to 50 A for diverse power levels.

Overview

Definition and Function

A TRIAC, or , is a three-terminal belonging to the family, designed to conduct current bidirectionally when triggered by a gate signal. It features a four-layer p-n-p-n structure, similar to other thyristors like the silicon-controlled rectifier (SCR), but unlike the unidirectional SCR, the TRIAC allows current flow in both directions between its main terminals. This bidirectional capability makes it particularly suited for (AC) applications, where it functions as an that remains on until the current falls below a holding threshold, typically at the AC cycle's zero-crossing point. Structurally, a TRIAC can be conceptualized as two SCRs connected in reverse-parallel configuration, with their gates linked to a single control , enabling control of larger currents using a small signal. The device has three terminals: the (G) for triggering and two main terminals (MT1 and MT2) for the load path, allowing it to switch on in response to either positive or negative pulses relative to the main terminals. Once triggered, it provides a low-resistance path for , effectively latching into conduction without continuous drive, which enhances efficiency in scenarios. The primary functions of a TRIAC center on regulation, including on-off switching and to vary the effective power delivered to a load. By adjusting the timing of the within each half-cycle, it enables precise power modulation, commonly used for applications such as light dimming in lamps or speed in motors and fans. This capability stems from its ability to handle both polarities of waveforms, distinguishing it from unidirectional devices and making it a versatile component in household and industrial circuits.

Historical Development

The development of the TRIAC traces its roots to foundational research on PNPN semiconductor structures conducted at Bell Laboratories in the 1950s. In 1956, a seminal paper by J.L. Moll and colleagues described the p-n-p-n switch, which demonstrated the principles of regenerative switching in four-layer devices, laying the groundwork for later technologies. This work influenced subsequent innovations by highlighting the potential for controlled conduction in silicon-based structures. Building on this research and the late-1950s commercialization of the (SCR) at in 1957, the TRIAC emerged as a bidirectional extension of SCR technology. In the early , F. William "Bill" Gutzwiller at invented the TRIAC, creating a device capable of conducting in both directions of , which addressed limitations in AC power control applications. The name "TRIAC" derives from "Triode for ," reflecting its triode-like gate control for bidirectional operation. General Electric patented the TRIAC design, with Gutzwiller's key patent granted on September 27, 1966 (filed earlier), formalizing its structure and fabrication. Commercialization followed in 1964, when GE introduced the device to the market as a versatile AC switch, initially for and controls. By the 1970s, TRIACs saw widespread adoption in , powering dimmer switches, motor speed controls in appliances like fans and drills, and early solid-state relays, driven by their compact size and reliability over mechanical switches. During the 1980s, advancements in fabrication techniques led to significant improvements in TRIAC voltage ratings, with commercial devices achieving blocking voltages up to 800 V and higher current handling, enabling broader use in higher-power household and industrial applications. These enhancements, including better planar processing and gate sensitivity, built on ongoing refinements from the original designs.

Device Representation

Circuit Symbol and Terminals

The circuit symbol of a TRIAC depicts two (SCR) symbols arranged in antiparallel configuration, connected diagonally to indicate bidirectional current flow, with a single gate terminal shared between them to represent the control input. This graphical representation emphasizes the device's ability to conduct in either direction once triggered, distinguishing it from unidirectional . In standard schematics, the main terminals are labeled MT1 and MT2, positioned at the ends of the symbol, while the gate (G) is shown extending from the junction near MT1. The terminals of a TRIAC are designated as follows: MT1 (main terminal 1) acts as the reference point for voltage measurements and is typically connected to one side of the supply; MT2 (main terminal 2) serves as the primary load connection point; and the (G) provides the triggering signal to initiate conduction. These designations are not interchangeable, as the 's triggering effectiveness depends on the relative to MT2, requiring careful in . Pinouts for through-hole packages like TO-220AB vary by manufacturer and specific device; they are not standardized. For example, in the BTA16, the TO-220AB pinout assigns pin 1 to MT2, pin 2 to MT1, and pin 3 to the (G). Designers must always consult the datasheet for the particular TRIAC to ensure correct and avoid circuit malfunction. Surface-mount variants, such as D2PAK, follow similar terminal assignments but adapt to the package's tab and lead layout for heat dissipation. For AC circuit applications, the TRIAC symbol is oriented with MT1 connected to the AC source's reference (often neutral or line) and MT2 to the load, ensuring the gate signal aligns with the desired triggering quadrant for symmetric operation across the mains cycle. This setup highlights the device's role in phase control, where the symbol's antiparallel thyristors visually convey the absence of inherent polarity preference in the main current path.

Equivalent Circuit Model

The equivalent circuit model of a TRIAC depicts it as two silicon controlled rectifiers (SCRs) connected in inverse parallel, sharing a common terminal to enable bidirectional conduction. In this representation, the main terminal MT1 functions as the for one SCR and the for the other, while MT2 serves in the opposite roles, allowing current to flow in either direction upon triggering. At its core, the TRIAC employs a five-layer PNPNP configuration, integrating the structures of the two SCRs into a compact device that supports flow through appropriately doped regions. This layered arrangement ensures that the device can latch into conduction bidirectionally once initiated by a signal. In the off-state, the TRIAC maintains between MT1 and MT2, blocking current until a sufficient overcomes the , at which point it switches to a low-impedance on-state with a typical of 1-2 V across the terminals, facilitating efficient power handling. This two-SCR model, while useful for basic analysis, has limitations in capturing the TRIAC's quadrant-specific gate sensitivities, stemming from inherent asymmetries in the doping and layer interactions that affect triggering efficiency across operational modes.

Operation

Basic Triggering Mechanism

The TRIAC, a bidirectional thyristor-like device, initiates conduction through a signal that forward-biases the junction, injecting minority carriers into the structure to enable flow between the main terminals (MT1 and MT2). This triggering requires either a positive or negative or voltage pulse, typically short in duration, to overcome the device's off-state blocking condition and switch it into the on-state with drop. Once triggered, the TRIAC latches into conduction, maintaining its on-state without further gate input as long as the principal through the device exceeds the latching ; this regenerative mechanism ensures stable operation during the conduction phase. The basic condition is satisfied when the gate I_G exceeds the gate I_{GT}, formally expressed as I_G > I_{GT}, where I_{GT} represents the minimum needed to initiate the regenerative process. Due to its bidirectional nature, the TRIAC naturally commutates or turns off when the AC load current drops below the holding current level, which typically occurs at the zero-crossing point of the waveform, allowing the device to reset for the next half-cycle without external intervention. Triggering sensitivity can vary depending on the polarity combination of the main terminal voltage and gate signal, corresponding to different operational quadrants.

Quadrant I

Quadrant I operation of a TRIAC occurs when the voltage at the MT2 terminal is positive with respect to MT1, and the gate voltage is also positive relative to MT1. In this mode, denoted as I+ or T2+ , the device is triggered into conduction by applying a positive pulse, which forward-biases the and injects minority carriers (electrons) into the structure, initiating regenerative feedback between the main terminals. Once triggered, the conduction path establishes from MT2 to MT1, allowing bidirectional flow until the main drops below the holding level at the end of the AC half-cycle. This mechanism leverages the TRIAC's five-layer structure, where the positive signal primarily affects the upper equivalent, enabling efficient turn-on. This represents the most sensitive mode for TRIACs, requiring the lowest (I_GT) among the four quadrants, typically in the range of 5 to 15 mA for standard devices, with faster turn-on times compared to other modes due to optimal injection alignment. For example, in the BT136 series TRIAC, the maximum I_GT in I is specified at 10 mA under standard test conditions (V_D = 12 V, I_T = 0.1 A, T_j = 25°C), highlighting its high sensitivity factor relative to quadrants , III, and , where higher (up to 50 mA or more) may be needed. The sensitivity arises from the direct injection of into the region of the equivalent SCR , minimizing the required pulse energy for latching. Due to its superior sensitivity and reliability, Quadrant I is the preferred operating mode for phase control applications in circuits, such as dimmer switches, motor speed controllers, and heating regulators, where precise and low-power triggering is essential for efficient full-wave conduction without excessive drive requirements. This mode ensures consistent performance in inductive or resistive loads, reducing the risk of false triggering while optimizing overall efficiency.

Quadrant II

In Quadrant II, the TRIAC operates with MT2 positive relative to MT1 (V_{MT2} > 0) and the gate negative relative to MT1 (V_G < 0), allowing conduction of current from MT2 to MT1 once triggered. This configuration applies a reverse bias to the gate junction, reducing triggering sensitivity compared to forward-biased scenarios. As a result, a higher gate trigger current I_{GT} is required, typically ranging from 15 to 30 mA depending on the device rating, such as 16 mA for a 4 A TRIAC. Triggering in this quadrant relies on hole injection from the gate region into the p-type silicon layer beneath MT1, which forward-biases adjacent junctions and activates the equivalent structure, leading to regenerative feedback with the PNP transistor pair for full conduction. This indirect injection path contributes to the elevated I_{GT} threshold due to the reverse gate polarity. The sensitivity in Quadrant II is medium, with I_{GT} approximately 2-3 times that of Quadrant I (e.g., 16 mA versus 10 mA for certain devices), making it less responsive but still viable for triggering. Applications for Quadrant II are limited to scenarios requiring an inverted gate drive relative to the positive MT2 polarity, such as certain AC control circuits, though it is less common than Quadrants I and III owing to the higher gate power demands and reduced efficiency.

Quadrant III

In Quadrant III, the TRIAC operates when the potential at main terminal MT2 (A2) is negative relative to MT1 (A1), and the gate current flows negatively with respect to MT1, corresponding to the negative of an AC supply. Under these conditions, the device conducts when the gate trigger current exceeds the threshold, allowing the main current to flow from MT1 to MT2 in the reverse direction compared to forward conduction. This reverse conduction path is enabled by the internal structure, where the negative gate signal reverse-biases key junctions, initiating regenerative feedback similar to the off-state to on-state transition in a . The triggering sensitivity in this quadrant is moderate, with the gate trigger current (I_GT) typically in the range of 15-30 mA for standard devices, comparable to Quadrant II and symmetric with Quadrant I, ensuring reliable activation without requiring excessively high gate drive levels. For instance, in devices like the BTA26 series, the maximum I_GT for Quadrant III is specified at 35 mA under test conditions of 12 V gate voltage and 25°C junction temperature, highlighting the practical threshold for turn-on. This level of sensitivity supports efficient control circuits while maintaining robustness against noise. The bidirectional symmetry of the TRIAC ensures that Quadrant III performance mirrors Quadrant I but with inverted polarity, providing balanced conduction characteristics across the full AC waveform and minimizing harmonic distortion in load control. This opposition-polarity mirroring is inherent to the device's inverse-parallel thyristor equivalent model, where the negative MT2 voltage activates the complementary structure for reverse current flow. Consequently, Quadrant III operation is essential for full-wave AC applications, such as phase-controlled dimming and universal motor drives, enabling complete cycle utilization for optimal power efficiency and smooth operation.

Quadrant IV

Quadrant IV operation in a TRIAC occurs when the voltage at main terminal MT2 is negative with respect to MT1 (V_MT2 < V_MT1), while a positive current is applied relative to MT1 (I_G > 0). In this mode, current conduction, once triggered, flows from MT1 to MT2, effectively utilizing the reverse-blocking structure of . However, the positive polarity relative to the negative MT2 creates challenges in initiating conduction due to the inherent in the TRIAC's bidirectional structure. This quadrant is the least sensitive for triggering among the four, requiring the highest (I_GT) to initiate turn-on, often in the range of 25-50 mA or more depending on the device rating and temperature. For example, in a 4 A TRIAC, I_GT may reach 27 mA at 25°C, compared to approximately 10 mA in I, representing a roughly 2.5-3 times lower. Triggering in IV can be unreliable, with potential for erratic or failed activation, particularly under varying load conditions or at higher temperatures, necessitating robust gate drive circuits with steep rising edges (e.g., 1 μs at least twice I_GT). The conduction in Quadrant IV exhibits poor efficiency primarily due to the elevated gate power requirements and slower turn-on response, which can lead to higher overall losses in the control . Latching current (I_L) is typically around 13-20 mA for standard devices, but the mismatch between gate injection and the reverse MT2 path reduces the speed and reliability of the regenerative process essential for full conduction. As a result, many TRIAC datasheets and application notes mark Quadrant IV operation as "not recommended" unless specifically required, and alternistor-type TRIACs are designed to block triggering entirely in this mode to enhance dv/dt immunity.

Electrical Characteristics

Currents: Gate Threshold, Latching, and Holding

The gate threshold current, denoted as I_{GT}, represents the minimum gate current required to initiate conduction in a TRIAC, effectively triggering the device from its off-state to on-state. This current must flow into or out of the terminal relative to the main terminals (A1 and A2) to overcome the internal blocking structure, typically varying by the of operation due to differences in voltage polarities across the main terminals. For standard TRIACs, I_{GT} typically ranges from 5 mA to 50 mA, with lower values in quadrants I, II, and III (e.g., around 5-25 mA maximum for devices like the BTA12 series) and potentially higher in quadrant IV (up to 50-100 mA maximum). The triggering condition is satisfied when the applied gate current meets or exceeds I_{GT}, i.e., I_G \geq I_{GT}, ensuring reliable turn-on without false triggering. Once triggered, the latching current, I_L, is the minimum principal (load) current through the main terminals that must be sustained to maintain the TRIAC in the on-state after the gate signal is removed. If the load current drops below I_L immediately following gate removal, the device will revert to the off-state, as the regenerative feedback within the TRIAC's structure fails to self-sustain conduction. Typical values for I_L in standard TRIACs range from 10 mA to 50 mA, with variations by quadrant—often highest in quadrant II (e.g., up to 80 mA maximum for BTA12 standard types) and lower in others (10-40 mA maximum in quadrants I, III, and IV). The latching condition requires the load current to exceed I_L, i.e., I_{load} > I_L, which is critical for applications where the gate pulse duration is short, ensuring the load current ramps up sufficiently before gate cessation. The holding current, I_H, defines the minimum load current necessary to keep the TRIAC conducting indefinitely once latched, without any gate assistance; below this , the device turns off as the internal diminishes. I_H is inherently lower than I_L to allow stable on-state operation under varying loads, with typical values around 10-30 for standard TRIACs (e.g., 15-25 mA maximum for BTA12 series, decreasing with higher temperatures). This parameter ensures the TRIAC remains on during normal conduction cycles but commutates off naturally when current falls below I_H, such as at zero-crossing in circuits. Quadrant-dependent differences exist, with I_H sometimes varying slightly by ( vs. ), but the is to establish the conduction sustainment limit.

Voltage Ratings and Static dv/dt

The voltage ratings of a TRIAC define its ability to withstand applied voltages in both off-state and on-state conditions without failure or unintended conduction. The repetitive peak off-state voltage, denoted as V_{DRM} (for forward blocking) and V_{RRM} (for reverse blocking), represents the maximum peak voltage the device can block repeatedly at line frequencies of 50-60 Hz, typically ranging from 200 V to 800 V depending on the device series and intended application. These ratings ensure the TRIAC remains in its non-conducting state under normal mains conditions, with exceeding them risking or permanent damage. During conduction, the on-state voltage drop V_{TM} is the peak voltage across the main terminals when the device is fully turned on, typically measuring 1 to 2 V at rated surge currents such as 16 A or higher. This low drop contributes to efficient power handling, as the power dissipation is primarily V_{TM} \times I_T, where I_T is the on-state current, minimizing heat generation in applications like or dimmers. The static dv/dt rating specifies the maximum rate of rise of off-state voltage across the main terminals (MT1 and MT2) that the TRIAC can tolerate without spurious triggering, with typical values spanning 10 V/µs to 500 V/µs across standard and enhanced devices. Exceeding this limit induces a capacitive through the internal gate-to-MT2 (C_{gk}), which can mimic a gate trigger signal and cause false turn-on, particularly in noisy environments or with inductive loads. This phenomenon arises because the capacitive current i_c = C_{gk} \cdot dv/dt flows into the gate, and if it surpasses the gate trigger current threshold I_{GTM}, the device latches into conduction. The safe operating condition is thus given by the inequality: \frac{dv}{dt} < \frac{I_{GTM}}{C_{gk}} where I_{GTM} is the minimum gate trigger current and C_{gk} is the gate-to-MT2 junction capacitance, emphasizing the role of device parasitics in voltage slew tolerance.

Current Change Rates: Critical di/dt and Commutating Limits

The critical di/dt, also known as the maximum rate of rise of on-state current, specifies the highest allowable rate at which current can increase immediately following gate triggering in a TRIAC. This parameter, typically ranging from 10 to 100 A/µs across standard devices, ensures uniform current spreading across the silicon die to avoid localized hot spots that could cause thermal runaway or device destruction. Exceeding this limit concentrates current in narrow filaments within the semiconductor, leading to overheating and potential failure; thus, the operational condition requires \frac{di}{dt} < (di/dt)_{\text{crit}} to prevent filament formation. For example, in a 16 A TRIAC like the BTA16 series, the rated critical di/dt is 50 A/µs under conditions of gate current at twice the threshold and rise time ≤ 100 ns. In contrast, the commutating di/dt governs the maximum rate of decrease of the on-state current during turn-off, particularly at the current zero-crossing in inductive or reactive loads. This limit, often on the order of 8 to 20 A/ms for standard TRIACs, prevents re-triggering caused by residual stored charge in that could erroneously activate the opposite conduction . High commutating di/dt values risk incomplete charge recombination, sustaining a low-level conduction path and leading to unintended turn-on without gate signal. Device datasheets, such as for the BTA16, specify minimum commutating di/dt ratings of 8.5 A/ms at a junction temperature of 125°C and controlled dv/dt conditions. The related commutating dv/dt defines the maximum rate of rise of the reapplied off-state voltage during the commutation interval following zero-crossing. Typical limits for standard TRIACs fall between 5 and 20 V/µs, beyond which induces gate-equivalent s that can spuriously trigger the device. This parameter is particularly critical in circuits with inductive loads, where rapid voltage recovery after fall can exacerbate re-triggering risks if not managed within the device's rated . For instance, the BTA16 series rates commutating dv/dt at a minimum of 5 V/µs under gate-open conditions and 67% of the peak repetitive voltage. These and voltage change rates during commutation are interdependent, with higher di/dt often correlating to stricter dv/dt requirements to maintain reliable turn-off.

Protection Techniques

Snubber Circuits

Snubber circuits employ networks connected in parallel across the TRIAC's main terminals (MT1 and MT2) to suppress voltage transients and prevent false triggering due to rapid voltage changes. The in the network typically ranges from 10 to 100 Ω to provide , while the ranges from 0.01 to 0.1 µF to store and release energy, effectively limiting the dv/dt across the device. The design of these snubbers focuses on the RC time constant selected based on the TRIAC's dv/dt rating, load characteristics, and required damping to limit voltage transients and ensure proper energy absorption, often acting as a low-pass filter to attenuate higher-frequency noise. This time constant allows the capacitor to charge and discharge smoothly, reducing voltage overshoot and oscillations that could exceed the TRIAC's dv/dt rating. RC snubbers are used for both resistive and inductive loads; for inductive loads, the design absorbs the stored magnetic energy, converting it to heat in the resistor rather than allowing it to generate high-voltage spikes. Simple snubbers suffice for resistive loads, where voltage transients are minimal, but for inductive loads, the RC values are adjusted to handle the higher energy from inductive kickback. These circuits significantly enhance TRIAC performance by improving immunity to dv/dt-induced triggering, allowing reliable operation in noisy environments. This mitigation addresses the inherent dv/dt of TRIACs.

Commutation and False Triggering Mitigation

Commutation in TRIACs involves managing the turn-off process during zero-crossings, particularly with inductive loads where rapid changes in (di/dt) can lead to re-triggering if not controlled. Inductive snubbers, consisting of series s placed in series with the load, soften the commutation by slowing the rate of decay, allowing sufficient recovery time for the device. For instance, a small (e.g., 33 turns of #18 wire on a 3/4" ) in series with the load can delay the zero-crossing by approximately 4 µs, improving turn-off reliability without excessive power loss. These aids are essential for applications with partially reactive loads, where the commutating di/dt must remain below the device's rated critical value to prevent . False triggering of TRIACs, often induced by (EMI) or voltage transients, can be mitigated through gate drive and noise suppression techniques. Opto-isolators, such as photo-triac couplers, provide electrical between the and the TRIAC , preventing noise from low-voltage to the high-voltage while ensuring safe triggering currents (typically 5-15 ). EMI filters, including shielded wiring and gate absorbers (e.g., RC networks with 100-1 kΩ and 0.01-0.1 µF ), suppress induced noise from supply fluctuations or nearby switching events, reducing the risk of unintended turn-on. Additionally, metal-oxide varistors (MOVs) placed at the input can clamp overvoltages from electrical fast transients (EFT), avoiding breakover-induced false ignition. Advanced methods for safe TRIAC operation incorporate zero-crossing detection circuits, which synchronize triggering to the AC waveform's zero-voltage point, minimizing inrush currents and . Optically isolated zero-cross triac drivers (e.g., MOC3061 series) detect the zero-crossing internally via high-voltage SCRs and delay triggering until the voltage is near zero, offering transient immunity up to 5000 V/µs and withstand of 7.5 kV. This approach is particularly effective for inductive loads like motors, where it reduces audible noise and stress during repeated on-off cycles. A specific implementation for di/dt limiting involves series chokes (e.g., 1.9 mH for a 10 kVA system) placed with the load, which saturate post-commutation to provide a brief delay in voltage rise, ensuring the TRIAC's recovery time (tens of microseconds) and limiting current decay rates to safe levels like 50 A/ms.

Applications

Traditional Uses

TRIACs have been employed in traditional control applications since their commercialization in the late 1960s and early 1970s, enabling simple, cost-effective phase-angle control for resistive and inductive loads in household and industrial settings. These devices revolutionized everyday electrical controls by allowing bidirectional switching of mains without parts, replacing older rheostat-based methods. One of the most common traditional uses of TRIACs is in light dimmers for incandescent bulbs, where phase-angle control adjusts the firing angle to vary the effective voltage delivered to the load. A typical employs a to charge a , which triggers a once its voltage reaches the breakover threshold, providing a sharp pulse to the TRIAC gate for precise conduction control throughout the cycle. This setup, widely adopted in residential and from the , allows users to smoothly dim lights from full brightness to off, improving and ambiance. TRIACs also facilitate motor speed control in applications such as ceiling fans, power tools, and small appliances, by modulating the voltage to the universal motor windings through similar phase-shifting techniques. The potentiometer-diac-TRIAC configuration enables adjustable speed from standstill to full rate, with the ensuring reliable triggering despite inductive back-EMF from the motor. Introduced in consumer products during the , this approach provided a compact to multi-tap transformers, enhancing user control in ventilation and tooling equipment. In heating elements, such as those in electric irons, , and space heaters, TRIACs regulate by proportionally controlling power delivery via phase-angle firing, maintaining steady heat output through from thermostats or simple timers. The resistive of these loads makes them ideal for direct TRIAC switching, with circuits often incorporating the same principle using a for gate drive to minimize harmonic distortion. This application, prevalent since the , ensured safer and more efficient thermal management in domestic appliances compared to on-off cycling. Simple TRIAC circuits, particularly those with direct gate drive from a diac in a relaxation oscillator configuration, form the basis of many early dimmers and controllers, offering robust full-wave control without microprocessors. The diac's symmetric triggering provides consistent pulses across both AC half-cycles, paired with a variable resistor for user adjustment, making these designs reliable for the aforementioned uses in pre-digital eras.

Modern and Emerging Applications

In modern smart systems, TRIACs enable precise phase-angle control for dimming LED and (CFL) fixtures, integrating seamlessly with platforms to support remote monitoring and automated adjustments for . TRIAC-dimmable drivers ensure compatibility by mitigating flicker through advanced controls, allowing smooth operation in connected environments like smart homes and buildings. This integration facilitates and user customization via apps, enhancing overall system responsiveness. The global TRIAC dimming system market, driven by these advancements, is valued at USD 215.9 million in 2025 and projected to reach USD 401.6 million by 2035, reflecting a (CAGR) of 6.4%. Emerging trends include AI-driven to optimize performance in commercial spaces. In , TRIACs paired with opto-couplers serve as solid-state relays (SSRs) to control appliances through microcontrollers (MCUs), enabling safe isolation between low-voltage control signals and high-voltage AC loads. This setup allows voice-activated commands from assistants, processed via IoT modules like or , to trigger TRIAC gating for on/off switching or speed regulation of devices such as fans. For instance, an Android-based voice interface sends signals to the MCU, which activates the opto-coupler to fire the TRIAC, turning appliances on or off without mechanical contacts, reducing wear in smart environments. Such systems support or cloud connectivity for seamless integration, as demonstrated in prototypes using BT136 TRIACs and MOC3021 opto-couplers for precise appliance management. TRIACs facilitate soft-start mechanisms in renewable energy setups by gradually ramping up voltage through phase control, minimizing inrush currents in inverters and AC-coupled solar systems. In off-grid or hybrid solar configurations, TRIAC-based circuits limit startup surges for induction motors or compressors, protecting battery banks and inverters from overloads—reducing peak currents by up to 70% in applications like air conditioning tied to photovoltaic arrays. For AC coupling, where battery inverters synchronize with grid-tied solar outputs, TRIACs enable controlled connection to avoid transient disturbances, enhancing system stability and efficiency in variable renewable sources. This approach is particularly valuable in single-phase setups for renewable energy applications, where alternate TRIAC-driven startup methods optimize motor performance without excessive harmonics. In the automotive sector, TRIACs provide AC phase control in electric vehicle (EV) charging stations, particularly for Level 2 systems where they manage power flow from to onboard chargers. By adjusting firing angles, TRIACs enable efficient power control and limiting in three-phase AC-DC converters, supporting bidirectional capabilities for (V2G) operations. Redundant TRIAC topologies in charging infrastructure ensure fault isolation, maintaining continuous power delivery during faults by gating auxiliary switches to stabilize the DC link. As EV adoption grows, these applications contribute to smarter grid integration, with highlighting TRIAC/SCR hybrids for phase-shift control to reduce startup stresses in medium-voltage stations.

Advanced Types

Standard TRIACs

Standard TRIACs, also known as four- (4Q) devices, enable bidirectional conduction in AC circuits by supporting triggering in all four quadrants of operation, where the quadrants are defined by the polarities of the main terminal voltage (MT2 relative to MT1) and the current relative to MT1. However, quadrant IV—characterized by positive MT2 voltage and negative current—exhibits the lowest , often requiring significantly higher trigger currents (up to several times those of quadrant I) compared to the other quadrants, which limits reliable triggering under certain conditions without optimized drive circuits. These devices typically handle RMS on-state currents up to 40 A and repetitive peak off-state voltages up to 800 V, making them suitable for medium-power switching applications such as motor controls and lighting dimmers. For inductive loads, standard TRIACs necessitate external circuits to suppress voltage transients and prevent false triggering or device failure during commutation, as their inherent dv/dt immunity is limited without such protection. Standard TRIACs are available in both through-hole packages, such as and TOP-3 for higher power dissipation, and surface-mount devices (SMD) like D²PAK and SMB flat for compact designs, offered by leading manufacturers including and (formerly ON Semiconductor). Their cost-effectiveness, with unit prices around $0.50 in moderate volumes, positions them as economical choices for general-purpose in consumer and industrial electronics.

High-Commutation (Two- and Three-Quadrant) TRIACs

High-commutation TRIACs are specialized variants engineered to enhance turn-off performance during rapid voltage and changes, particularly in inductive loads, without relying on external components like snubbers. These devices achieve this through modified internal structures that improve dv/dt and di/dt handling, making them suitable for demanding AC switching applications. Two-quadrant high-commutation TRIACs are optimized for operation in quadrants I and III, where the main terminal voltage (MT2) and gate polarities align positively (Q1: MT2 positive, gate positive) or both negatively (Q3: MT2 negative, gate negative), while disabling quadrants II and IV to avoid commutation vulnerabilities. This selective triggering allows for significantly higher critical rate of change, with di/dt ratings up to 100 A/µs at elevated temperatures, enabling robust performance under high inductive loads without false triggering. Three-quadrant high-commutation TRIACs, often termed Alternistor or snubberless types, extend functionality to quadrants I, , and III, incorporating advanced PNPN structures for superior commutation. These devices deliver high dv/dt immunity during commutation, with static (dv/dt)_c ratings typically exceeding 500 V/µs and no specific limitation requiring external snubbers for turn-off in inductive loads. Examples include ' ACS series, which operate in quadrants and III (a two-quadrant subset but with high-commutation traits) and Littelfuse's Q-series Alternistors for full three-quadrant use, both supporting applications like motor controls in washing machines and switching in LED drivers. While these high-commutation TRIACs offer reduced component count and enhanced reliability by obviating snubbers and inductors, they incur higher manufacturing costs due to specialized designs and may limit circuit flexibility owing to restricted quadrants compared to standard four-quadrant devices.

Specifications and Comparisons

Typical Parameter Data

TRIACs are characterized by several key electrical parameters that determine their suitability for various applications. Common specifications for standard TRIACs include an RMS on-state current rating (I_T(RMS)) ranging from 4 A to 16 A, a repetitive peak off-state voltage (V_DRM) of V, a gate current (I_GT) for 1 typically between 10 mA and 35 mA, a critical rate of rise of off-state voltage (dv/dt) of 200 V/µs minimum, and a critical rate of rise of on-state current (di/dt) of 50 A/µs. For a representative example, the BTA16 series (a 16 A TRIAC in TO-220AB package) provides the following typical parameter values under standard test conditions (T_j = 25 °C unless otherwise noted). These values are derived from manufacturer datasheets and illustrate performance for mains power AC switching.
ParameterSymbolValue (Standard Version)Conditions
RMS On-State CurrentI_T(RMS)16 AT_c = 100 °C, full sine wave
Repetitive Peak Off-State VoltageV_DRM600 V-
Gate Trigger Current (Q1)I_GT25 mAV_D = 12 V, R_L = 33 Ω
Critical Rate of Rise of Off-State Voltagedv/dt200 V/µsV_D = 2/3 V_DRM, gate open, T_j = 125 °C
Critical Rate of Rise of On-State Currentdi/dt50 A/µsI_G = 2 I_GT, T_j = 125 °C
Non-Repetitive Surge CurrentI_TSM160 A50 Hz, half sine wave, t_p = 20 ms, T_j initial = 25 °C
Temperature dependencies significantly affect TRIAC operation; for instance, I_GT decreases with increasing (T_j); relative to 25 °C values, it is approximately 1.5 times higher at -40 °C and 0.5 times lower at 125 °C, which may require higher gate drive at low temperatures. Similarly, I_T() derates with case temperature (T_c), dropping to approximately 0 A at T_c = 125 °C per the derating curve. Surge ratings like I_TSM are non-repetitive and specify peak currents for short pulses, such as 160 A for a 20 ms half-sine wave at 50 Hz. The TRIAC, or triode for alternating current, differs fundamentally from the silicon-controlled rectifier (SCR) in its conduction capability. While an SCR is a unidirectional device that conducts current in one direction only, from to once triggered, a TRIAC is bidirectional, functioning equivalently to two SCRs connected in antiparallel with a shared , allowing current flow in both directions across its main terminals. This makes the TRIAC simpler and more suitable for control applications, such as dimmers and motor speed controllers, where bidirectional switching is essential. However, SCRs are generally more robust for high-power applications due to their unidirectional design, which avoids the commutation challenges TRIACs face in DC circuits, where the device latches on and requires current to drop to zero for turn-off—impossible in steady DC without additional circuitry. In comparison to MOSFETs and IGBTs, TRIACs offer cost advantages for AC mains switching, typically being cheaper per unit for equivalent voltage and current ratings in line-frequency applications, and requiring only a single device without the need for parallel configurations or anti-parallel pairs to handle . Unlike MOSFETs, which include an inherent diode that can cause issues in AC rectification or freewheeling, TRIACs lack this diode and provide inherent bidirectional conduction without additional components. However, TRIACs exhibit slower switching speeds, limited to line frequencies (e.g., 50-60 Hz) with latching behavior that precludes fine (PWM) control, making MOSFETs and IGBTs preferable for high-frequency applications like switch-mode power supplies (SMPS) or inverters, where rapid switching minimizes losses. Compared to electromechanical relays, TRIACs provide solid-state reliability with no mechanical contacts, eliminating wear and offering virtually unlimited operational cycles—often exceeding millions—versus the limited lifespan of relays (typically to cycles) due to arcing and physical . This longevity makes TRIACs ideal for frequent switching in solid-state relays (SSRs), and they can handle higher frequencies than mechanical relays without contact bounce. Nonetheless, TRIACs generate more heat from their on-state (around 1-2 V), necessitating heat sinking, whereas relays isolate better without thermal management in low-power scenarios.
DeviceCost (for AC Mains)Switching SpeedBidirectional CapabilityPower Handling (High DC)LongevityHeat Management Needs
TRIACLowLow (line freq.)YesLimitedHigh (millions of cycles)High (heat sink required)
SCRLowLow (line freq.)NoHighHigh (millions of cycles)Moderate
MOSFET/IGBTHighHigh (kHz-MHz)Requires configurationHighHigh (electronic)Low (efficient)
ModerateLow (mechanical)Yes (via contacts)ModerateLow (50k-100k cycles)Low

References

  1. [1]
    Triac Tutorial and Triac Switching Circuits - Electronics Tutorials
    The Triac is a high-speed solid-state device that can switch and control AC power in both directions of a sinusoidal waveform.
  2. [2]
    TRIAC: What is it? (Definition, Operation & Applications) - Electrical4U
    Jun 26, 2024 · A TRIAC is defined as a three-terminal AC switch that can conduct in both directions, unlike other silicon controlled rectifiers.
  3. [3]
    An Introduction to TRIAC Basics - Technical Articles - EEPower
    Jan 27, 2021 · A TRIAC is a bidirectional, three-electrode AC switch that allows electrons to flow in either direction.
  4. [4]
    [PDF] T4 series - 4 A Triacs - STMicroelectronics
    Nov 14, 2016 · 4 A Triacs. Datasheet - production data. Features. • Three quadrants Triac. • 600 to 800 V VDRM/VRRM. Applications. • General purpose AC ...
  5. [5]
    [PDF] Datasheet - T5035H-8PI - 50 A - 800 V - 150 °C 8H - Triac in TOP3 Ins.
    Sep 3, 2023 · This 50 A Triac housed in TOP3 insulated is designed to operate at 800 V and. 150 °C. The T5035H-8PI Triac provides an enhanced thermal ...<|control11|><|separator|>
  6. [6]
    Thyristors | Solid-state Device Theory | Electronics Textbook
    Thyristors are a broad classification of bipolar-conducting semiconductor devices with four (or more) alternating NPNP layers.
  7. [7]
    (PDF) Triac: Principle, Structure, Working with Application Circuits
    Jul 9, 2020 · A “Triac” is another 4-layer, 3-terminal thyristor device similar to the SCR. The Triac can be triggered into conduction in either direction.
  8. [8]
    Understanding TRIACs: The key to efficient AC power control in ...
    May 26, 2025 · The TRIAC structure forms two internal thyristor paths that can conduct in both directions. TRIAC working principles. Unlike other thyristors, ...Triac Symbol · Triac Structure · Triac Working Principles<|control11|><|separator|>
  9. [9]
    General Electric Device That Revolutionized Electrical Machines Is ...
    Jul 22, 2019 · General Electric introduced the silicon-controlled rectifier (SCR), a three-terminal p-n-p-n device, in 1957. The gas-filled tubes used ...
  10. [10]
  11. [11]
    (PDF) Celebrating 65th Anniversary of the Transistor - ResearchGate
    Aug 10, 2025 · ... TRIAC. Triode for Alternating Current (a bidirectional switching ... patent applications was October 1925. These. patents were ...
  12. [12]
    [PDF] Power Electronics Milestones
    GE produces the Convair Skylark, GE CJ805, fastest jet engine for commercial use ... 9/27/66 Bob Gutwiller (GE) granted patent for Triac AC switch www ...
  13. [13]
  14. [14]
    Why Use a Triac?, April 1974 Popular Electronics - RF Cafe
    Apr 18, 2017 · A triac is basically the equivalent of two SCRs (silicon-controller rectifier, aka thyristor) connected back-to-back, allowing it to conduct on ...
  15. [15]
    [PDF] Semiconductors Thyristors Triacs Accessories - Bitsavers.org
    A group of figures indicating the typical operating voltage Vz for each type at the nominal operating current I z rating of the range. The letter V is used ...
  16. [16]
    (PDF) The Sixth Decade of the Thyristor - ResearchGate
    Aug 10, 2025 · Fig. 15 The first thyristor devices were released commercially in 1956 by General Electric (GE), as a replacement for the thyratron, a vacuum ...
  17. [17]
    The TRIAC | Thyristors | Electronics Textbook - All About Circuits
    When used to control AC power to a load, TRIACs are often accompanied by DIACs connected in series with their gate terminals. The DIAC helps the TRIAC fire more ...
  18. [18]
    None
    ### Pin Configuration for TO-220 Package
  19. [19]
    What is TRIAC? Symbol, Construction, Working and Applications
    TRIAC is an acronym that stands for “Triode for Alternating Current”. Triode means a three-terminal device while AC means that it is used for switching ...
  20. [20]
    All You Need to Know About TRIACs - ASAP Semiconductor
    May 12, 2022 · The basic structure of a TRIAC consists of five alternating layers of P-type and N-type semiconductor material, forming a complex PNP NPN ...
  21. [21]
    [PDF] AN2703: Parameter list for SCRs, Triacs, AC Switches, and Diacs
    Peak on-state voltage drop. This is the voltage across the device while it is on-state. It is specified at the peak current corresponding to the. IT(RMS) ...
  22. [22]
    None
    ### Summary of TRIAC Triggering Mechanism
  23. [23]
    None
    ### Summary of TRIAC Basic Triggering Mechanism
  24. [24]
    None
    ### Summary of Gate Trigger Current (I_GT) for Quadrant I from BT136-600E Datasheet
  25. [25]
    Triac Principles and Circuits — Part 1 | Nuts & Volts Magazine
    A triac is a controllable medium- to high-power semi-latching solid-state AC power switch. This two-part article explains its basic operation and shows various ...Missing: adoption consumer 1970s
  26. [26]
    [PDF] AN1002
    Optimum triac gate sensitivity is achieved when operating in Quadrants I and III due to the inherent thyristor chip construction. If Quadrants I and III cannot ...
  27. [27]
    [PDF] Datasheet - Z01 - Standard 1 A Triacs - STMicroelectronics
    May 9, 2005 · The Z01 series is suitable for general purpose AC switching applications. These devices are typically used in applications such as home ...
  28. [28]
    [PDF] SPEED CONTROL OF INDUCTION MOTOR USING TRIAC - JETIR.org
    In this case, the injection of holes in the p-silicon makes the stacked n, p and n layers beneath MT1 behave like a. NPN transistor, which turns on due to the ...
  29. [29]
    [PDF] Datasheet - BTA26, BTB26 - 800 V and 600 V, 25 A standard Triacs ...
    Jul 2, 2023 · Electrical characteristics (Tj = 25 °C, unless otherwise specified) - Snubberless and Standard (3 quadrants). Symbol. Parameters. Quadrant. BTA ...
  30. [30]
    [PDF] an303-thyristors-and-triacs-latching-current ... - STMicroelectronics
    Apr 24, 2009 · In Figure 7, push button C is used to trigger the TRIAC. The value of the gate current IG is set to a higher value than the gate current ...Missing: mechanism | Show results with:mechanism
  31. [31]
    [PDF] Gating, Latching, and Holding of SCRs and Triacs
    Special consideration should be given to gating circuit design when Quadrants I and IV are used in actual application, because Quadrant IV has the lowest gate.
  32. [32]
    [PDF] AN1048/D - onsemi
    Also devices should be tested in the application circuit at the highest possible temperature using thyristors with the lowest measured trigger current. TRIAC ...Missing: IV | Show results with:IV
  33. [33]
    Triac Universal Motor Speed Control Circuit Design Basics - EEPower
    Jun 2, 2022 · The Triac used is a three-quadrant Triac that can be triggered by a gate signal that is (a) positive with MT2 positive, (b) negative with MT2 ...
  34. [34]
    [PDF] Datasheet - BTA12, BTB12, T1205, T1210, T1235, T1250
    Feb 2, 2017 · Available either in through-hole or surface mount packages, the BTA12, BTB12 and. T12xx Triac series are suitable for general purpose mains ...Missing: I_L I_H
  35. [35]
    [PDF] Thyristors and TRIACs: holding current - an important parameter
    Mar 10, 2008 · The purpose of this note is to familiarize the users of TRIACs or thyristors with the hypostatic current parameter, IH, also known as the ...Missing: explanation | Show results with:explanation
  36. [36]
    [PDF] Controlling a Triac with a phototriac - AN5114 - Application note
    Nov 7, 2018 · This application note provides guidelines for proper operation of Triac controlled by means of phototriac. Constraints associated.Missing: explanation | Show results with:explanation
  37. [37]
    [PDF] Phototriac dV/dt Application Note - Vishay
    Oct 19, 2011 · The IL410 (zero-crossing) and IL420 (non-zero crossing) phototriacs offer the highest dV/dt performance in the industry at 10 kV/μs.
  38. [38]
    [PDF] AN439 - SNUBBERLESS and logic level Triac behavior at turn-off
    Apr 25, 2025 · Operation in Q1-Q2-Q3 quadrants. To make significant progress in the Triac technology is to essentially improve the turn-off behavior. In ...Missing: explanation | Show results with:explanation
  39. [39]
    [PDF] AN437 - RC snubber circuit design for triacs - STMicroelectronics
    Jan 17, 2024 · An RC snubber circuit must be used when there is a risk of triac spurious triggering, that is, when the dI/dtOFF -. dV/dtOFF couple, measured in ...
  40. [40]
    [PDF] Industrial triacs and their applications 1975-02
    Series chokes are usually needed to reduce the decay rate, —di/dt, of the commutation current to a value allowing safe turn-off (see Section 3.2.3) ; this value ...
  41. [41]
    [PDF] an-3004.pdf - onsemi
    A detailed discussion of a "snubber" network is given under the section "Inductive and Resistive Loads." Figure 4 shows a static dV/dt test circuit which can be ...
  42. [42]
    [PDF] AN5649 - How to evaluate and improve Triacs immunity to EFT bursts
    Jun 15, 2021 · Triac immunity to EFT bursts is evaluated by measuring the lowest EFT burst voltage that causes a lamp to flash, using a series lamp and ...
  43. [43]
    [PDF] Light dimmer circuits - Educypedia
    Between 1960-1970 thyristors and triacs came to market. Using those components it was quite easy to make small and inexpensive light dimmers which have good ...
  44. [44]
    [PDF] an3168-noninsulated-scr--triac-control-circuits ... - STMicroelectronics
    Jan 17, 2024 · Working in. Q2/Q3 quadrants is then advised, even for standard triacs, to decrease the board consumption and increase the board reliability. To ...Missing: explanation | Show results with:explanation
  45. [45]
    What are triacs, diacs and quadracs good for? - Power Electronic Tips
    Aug 2, 2022 · Triacs and quadracs are useful for ac line frequency power applications such as lighting, motor speed, and temperature controls.Missing: traditional | Show results with:traditional<|control11|><|separator|>
  46. [46]
    Understanding the Fundamentals of Triac Electronics - lgesemi
    It functions as a switch for alternating current (AC) power, enabling the regulation of electrical flow in various systems. Triacs belong to the thyristor ...
  47. [47]
    Diac Triac and Quadrac for AC Power Control - Electronics Tutorials
    The Diac or Diode Alternating Current switch are used with Triacs for power switching and AC power control applications.Missing: traditional elements
  48. [48]
  49. [49]
    Implementation of IoT and Voice control for Industrial Automation
    Aug 7, 2022 · The relay used has maximum current rating up to 7 Amp and to 32 Amp. Opto-coupler with TRIAC (Solid State Relay):. In industries there are ...Missing: coupled MCUs
  50. [50]
    Design and Implementation of a Smart Switchboard using ESP8266 ...
    Mar 16, 2025 · The fan control is performed using a MOC3021 optocoupler and a BT136 TRIAC for precise speed regulation. The relays are used for light control.
  51. [51]
    Using A Soft Starter with A Solar Energy System
    ### Summary of SureStart Soft Starter in Solar Energy Systems
  52. [52]
    (PDF) Single phase induction motor alternate start-up and speed ...
    This paper introduces an alternate start-up method by driving the SPIM with solid state electronics. This alternate method is achieved by driving a SPIM with a ...
  53. [53]
    Fault-isolation scheme strategy at the switch level.The TRIAC (TRA,...
    The TRIAC (TRA, TRB, TRC) of the faulty switch (S1,...,S6) is gated to connect the phase to the midpoint of the DC link. Onboard charging systems (OBCs) convert ...
  54. [54]
    An Active Inrush Current Limiter Based on SCR Phase Shift Control ...
    Aug 10, 2025 · This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium ...Missing: stations | Show results with:stations
  55. [55]
    Standard and snubberless triacs - STMicroelectronics
    ... The devices feature a reverse voltage up to 800 V and a maximum current up to 40 A. ST's package range offers a full through-hole and SMD porfolio.
  56. [56]
    [PDF] mac224a-d.pdf - onsemi
    (See Figure 1 for maximum case temperatures.) TRIACS. 40 AMPERES RMS. 200 thru 800 VOLTS. Device. Package. Shipping.
  57. [57]
  58. [58]
    [PDF] Thyristors Qxx12xHx Series - Littelfuse
    The alternistor triac will not operate in Quadrant IV. These are used in circuit applications requiring a high dv/dt capability.
  59. [59]
    [PDF] AN4363 How to select the triac, ACS, or ACST that fits your application
    The choices of the triggering quadrants depend only on the control circuit. Or vice versa, the control circuit choice depends on the operating quadrants of the ...
  60. [60]
    [PDF] QJxx30xHx &QJxx35xHx series - Littelfuse
    Jan 18, 2024 · This 30 A/35 A high temperature Alternistor TRIAC has. 150°C maximum junction temperature and 350 A. ITSM(60 Hz). This series enables easier ...Missing: onsemi | Show results with:onsemi
  61. [61]
    [PDF] Datasheet - T1610, T1635, T1650, BTA16, BTB16 - STMicroelectronics
    May 30, 2018 · These are 16A triacs with high commutation, low thermal resistance, and are for mains power AC switching, with 16A RMS current and 600/800V ...
  62. [62]
    [PDF] AN4608 - How to select the right thyristor (SCR) for your application
    Mar 25, 2016 · The thyristor device works as a silicon-controlled rectifier (SCR) so it can only conduct current to one direction. (see AN4607), while triac ...
  63. [63]
    [PDF] an4030-gate-to-cathode-capacitor-impact-on-triac-immunity-and ...
    First, triacs can conduct current in both directions. A triac is equivalent to two SCRs back-to-back with a common gate. The real gate area of the reverse SCR ...
  64. [64]
    [PDF] A modern approach to solid-state relay design - Texas Instruments
    Jul 27, 2016 · Because of the SCR's unidirectional functionality, a TRIAC configured with two SCRs in antiparallel controls AC current, as shown in Figure ...Missing: differences | Show results with:differences
  65. [65]
    [PDF] Characteristics of power semiconductors - STMicroelectronics
    They are the cheapest way of controlling AC currents, for example in AC motor speed controls or lamp dimmers. 11. CONCLUSION. “Power MOSFET has very high ...
  66. [66]
    [PDF] AN4993 - How to implement an SCR or a Triac in hybrid relay ...
    Mar 6, 2017 · This topology is used for heaters to increase relay lifetime and for midpower motor applications (for example, fans) where the inrush current ...Missing: explanation | Show results with:explanation
  67. [67]
    [PDF] TN1605H-8x RTM - 800 V High Temperature SCRs
    Relay. Performance comparison vs electromechanical relay. 5. Relay 16 A. 29 x 12.4 x 32.8 mm3. D²PAK. 4.3 x 10 x 8.95 mm3. Relay 16 A. 50 k cycles. Contact ...