Sievert

The sievert (symbol: Sv) is the for measuring the and effective dose of to humans, quantifying the biological health effects rather than the mere energy absorbed by tissues. It is used in to assess risks from sources such as , occupational exposure, and environmental , where 1 represents a dose that could produce significant effects like increased cancer risk. Unlike the (Gy), which measures as energy per unit mass (1 Gy = 1 J/), the sievert accounts for the varying biological damage caused by different radiation types, such as alpha particles versus gamma rays. The dose equivalent in sieverts is calculated as the in multiplied by a dimensionless weighting factor (formerly called the quality factor), which ranges from 1 for photons and electrons to 20 for alpha particles. For effective dose, an additional step weights the by tissue sensitivity factors to estimate whole-body risk. The sievert replaced the older in the international system in , with 1 Sv equivalent to 100 , facilitating global standardization in . The unit is named after Swedish medical physicist Rolf Maximilian Sievert (1896–1966), a pioneer in radiation protection who developed early measurement techniques and served as chairman of the International X-ray and Radium Protection Committee from 1928. Sievert's work on phantom dosimetry and exposure limits laid foundational principles for modern standards, influencing organizations like the International Commission on Radiological Protection (ICRP), where he was president from 1956 to 1962. Typical everyday exposures are far below 1 Sv, with natural background radiation averaging about 3 millisieverts (mSv) annually and a single chest X-ray around 0.2 mSv. Regulatory limits, such as 1 mSv per year for the public and 20 mSv annually for radiation workers, are set in sieverts to ensure safety.

Definition

Formal Definitions

The sievert (symbol: Sv) is the special name for the of dose equivalent, defined as equal to one joule per kilogram (1 Sv = 1 J kg⁻¹). This unit incorporates a dimensionless quality factor to account for the varying biological effectiveness of different types of relative to . The International Committee for Weights and Measures (CIPM) clarified in 2002 that the dose equivalent H is given by H = Q \times D, where D is the in gray (Gy) and Q is the quality factor determined by the of the radiation, ensuring the sievert distinguishes biological risk from mere energy deposition. The (ICRP) defines the sievert as the special name for the SI unit of , effective dose, and operational dose quantities, each expressed in joules per (J kg⁻¹). This emphasizes the sievert's in radiological by integrating type (via radiation weighting factors) and tissue (via tissue weighting factors) to estimate stochastic health risks, as outlined in ICRP Publication 60 (1990) and reaffirmed without substantive changes in Publication 103 (2007). As of 2025, the ICRP's 2007 recommendations remain the current standard, with no major revisions to the sievert's foundational . The sievert has its origins in mid-1970s efforts by the International Commission on Radiation Units and Measurements (ICRU) to adopt units for quantities. It was formally introduced by the ICRP in 1977 (Publication 26) to unify dose concepts in the system, replacing earlier units like the and providing a coherent measure for dose equivalent that factors in biological effects. This was recognized by the 16th General Conference on Weights and Measures (CGPM) in 1979 via Resolution 5, establishing it as an unit specifically for purposes.

Relation to Gray

The sievert (Sv) builds upon the gray (Gy), the International System of Units (SI) base unit for absorbed dose, which measures the amount of energy deposited by in a material. The gray is defined as an absorbed dose of 1 joule of energy per kilogram of mass, or 1 = 1 J/kg. This physical quantity, denoted as D, provides a measure of energy deposition without regard to the type or biological effects of the . To incorporate the differing biological impacts of various radiation types, the dose equivalent H is calculated by multiplying the absorbed dose D in grays by a quality factor Q—a legacy term from earlier dosimetry systems—or, in modern practice, by the radiation weighting factor w_R as recommended by the International Commission on Radiological Protection (ICRP). Thus, the sievert serves as the unit for dose equivalent, where 1 Sv = 1 Gy × w_R (or Q), enabling the assessment of stochastic health risks from ionizing radiation. This relation distinguishes the sievert from the gray by adjusting for the of particles: photons and electrons have w_R = , while heavier particles like alpha particles have higher values, such as w_R = , reflecting their greater potential for cellular damage per unit energy absorbed. For instance, an of Gy from alpha particles equates to an of Sv, highlighting how the sievert facilitates comparisons of biological harm across types.

Unit Symbol and Prefixes

The sievert is represented by the symbol , consisting of a capital "S" followed by a lowercase "v" with no period, except when the symbol concludes a sentence. This notation was formally adopted by the 16th General Conference on Weights and Measures (CGPM) in 1979 as the special name for the unit of dose equivalent in radioprotection. The symbol is never abbreviated as "sie," adhering to standard SI conventions that prohibit informal shortenings of unit names. SI prefixes are applied to the sievert for practical scaling in measurements, particularly in low-dose scenarios common to environmental and occupational monitoring. The most frequently used prefixes include the millisievert (mSv) and microsievert (μSv), with conversion factors as follows:
PrefixSymbolFactorConversion to Sv
Milli-mSv$10^{-3}1 mSv = $10^{-3} Sv
Micro-μSv$10^{-6}1 μSv = $10^{-6} Sv
These prefixes form inseparable symbols without spaces (e.g., mSv, μSv), as specified in the SI Brochure. Larger prefixes like kilisievert (kSv) are rare due to the high doses they imply, which exceed typical regulatory limits. The Bureau International des Poids et Mesures (BIPM) and the (IAEA) provide guidelines for sievert usage in scientific reports, labels, and safety documentation to ensure clarity and consistency. According to BIPM, a space must separate the numerical value from symbol (e.g., 2.5 mSv), unit symbols are printed in upright type without modification for plurals, and no period follows the symbol internally. IAEA publications emphasize SI compliance, recommending the sievert over legacy units like the (with 1 Sv = 100 rem noted for conversions) and using en dashes for dose ranges (e.g., 1–5 mSv). A common pitfall in notation arises from potential confusion between millisievert (mSv) and the velocity unit meters per second (m/s), though this is mitigated by the distinct contextual use in versus .

Dose Quantities

Physical Quantities

The physical quantities in provide the foundational measures of energy transfer and deposition from to matter, serving as the basis for deriving biologically weighted quantities like the sievert. These include , , and fluence, which quantify interactions without incorporating radiation type or sensitivity factors. Kerma, or kinetic energy released per unit , represents the initial transfer of kinetic energy from indirectly (such as photons or neutrons) to directly ionizing charged particles (like electrons) in a . It is defined as the of the sum of the initial kinetic energies of all charged particles liberated by uncharged particles in a small element divided by that :
K = \frac{dE_\text{tr}}{dm}
where dE_\text{tr} is the transferred energy and dm is the of the volume element. For monoenergetic photons, kerma relates to energy fluence \Psi (product of particle fluence and photon ) via the mass energy transfer coefficient \mu_\text{tr}/\rho:
K = \Psi \left( \frac{\mu_\text{tr}}{\rho} \right).
This quantity is particularly useful for describing energy deposition at the onset of interactions, before charged particles lose through subsequent collisions.
Absorbed dose measures the actual imparted to matter by after interactions, defined as the mean deposited per :
D = \frac{d\bar{\varepsilon}}{dm}
where d\bar{\varepsilon} is the average transferred to the dm. Under conditions of —where the number of s entering a volume equals those leaving— approximates collision (kerma excluding radiative losses): D \approx K_\text{col}. can be specified as a point value, representing the local deposition at a specific location, or as an organ-averaged value, which integrates the dose over the or volume of a or to assess overall exposure: D_{T,R}, the in T from type R, averaged over the volume. Point doses highlight localized effects, such as in radiotherapy hotspots, while organ-averaged doses provide a mean for broader evaluation. The for both kerma and is the gray (Gy), equivalent to 1 joule per (J/kg).
Fluence quantifies the incident radiation field as the number of particles passing through a unit area, typically an infinitesimal : \Phi = \frac{dN}{da}, where dN is the number of particles and da is the cross-sectional area (unit: m⁻²). Energy fluence \Psi = \Phi \cdot E (with E as average particle ) links directly to dose quantities; for example, absorbed dose in a medium relates to energy fluence via the mass energy absorption \mu_\text{en}/\rho: D = \Psi \left( \frac{\mu_\text{en}}{\rho} \right). This connection allows fluence measurements to estimate dose deposition, especially in uniform fields, though actual dose varies with material properties and geometry. These physical quantities in underpin sievert calculations by providing the unweighted metrics that are later modified for biological effectiveness.

Operational Quantities

Operational quantities in are defined by the International Commission on Units and Measurements (ICRU) as practical, measurable proxies for the protection quantities established by the (ICRP), enabling assessments of external through and calculations. These quantities, expressed in sieverts (Sv), approximate the biological effects of radiation by incorporating quality factors or radiation weighting factors into measurements at specified depths in idealized phantoms, without requiring full anatomical modeling of human tissues. Their primary role is to support the of dosimeters and survey meters, ensuring that instrument readings provide conservative estimates of potential health risks in diverse radiation fields. Central to the definition of many operational quantities is the ICRU sphere, a standardized consisting of a 30 constructed from tissue-equivalent material with a of 1 g/³ and elemental composition of 76.2% oxygen, 11.1% carbon, 10.1% , and 2.6% . This simulates for area monitoring purposes, where dose equivalents are computed at depths such as 10 for deeper-penetrating (relevant to ambient dose equivalents) or shallower depths like 0.07 mm for in directional fields. By expanding and aligning fields within or around this , the quantities account for scattered , providing a basis for environmental and workplace assessments that correlate reasonably with protection quantities like effective dose. Conversion coefficients link measurable physical quantities, such as particle fluence (particles per unit area) or air for photons, to operational dose equivalents, allowing estimation across various radiation types including photons, , electrons, protons, and heavier ions. These coefficients, calculated via simulations of radiation transport in the ICRU sphere or updated phantoms, vary with energy and field geometry; for example, neutron coefficients incorporate fluence-to-dose conversions that peak around 1 MeV due to interactions. Tabulated in seminal reports like ICRU Report 57 (1998) and extensively revised in the joint ICRU/ICRP Report 95 (2020), they enable instruments to display readings directly in sieverts for photons from diagnostic X-rays (e.g., coefficients around 1.2 pSv for 100 keV) to high-energy (up to 10 pSv at energies). This approach ensures practical application in without exhaustive biological computations, prioritizing overestimation for safety.

Protection Quantities

Protection quantities in radiological protection are sievert-based measures designed to estimate the stochastic health risks, such as cancer induction and heritable effects, from ionizing radiation exposure to humans. These quantities account for the varying biological effectiveness of different radiation types and the differing sensitivities of body tissues, providing a framework for assessing overall risk rather than physical energy deposition alone. Unlike absorbed dose, which is a fundamental physical quantity in grays, protection quantities incorporate weighting factors to better represent health detriments. The , denoted H_T, to a specific or T is calculated as the sum over all types R of the product of the radiation weighting factor w_R and the mean D_{T,R} in that : H_T = \sum_R w_R D_{T,R} This quantity expresses the dose in sieverts () and adjusts for the of the on effects in the targeted , enabling organ-specific evaluation. For instance, it is used to assess potential harm to radiosensitive organs like the from mixed fields. The unit of equivalent dose is the sievert, the same as for effective dose, emphasizing its role in protection contexts. The effective dose, denoted E, extends this by providing a whole-body through the tissue-weighted sum of equivalent doses across all specified organs and s: E = \sum_T w_T H_T Here, w_T represents the tissue weighting factor, which reflects the relative contribution of each tissue to total . Expressed in sieverts, effective dose allows comparison of risks from uniform or non-uniform exposures, equating them to the stochastic detriment from a whole-body uniform exposure of the same magnitude. This makes it particularly valuable for scenarios involving partial-body , where direct whole-body would underestimate or misrepresent the health impact. A key distinction between organ equivalent dose and effective dose lies in their scope: H_T focuses on the risk to individual tissues or organs, useful for targeted assessments like deterministic effects thresholds, whereas E integrates these into a single value representing the total body risk, facilitating broad protection strategies. In practice, effective dose serves as the primary quantity for regulatory limits and , such as annual limits of 20 mSv for radiation workers and 1 mSv for the public, ensuring compliance and optimization in planned exposure situations like medical diagnostics or occupational settings. These applications, as outlined in ICRP Publication 103, support prospective dose planning and verification against international standards.

Calculation of Protection Quantities

Radiation Weighting Factor

The radiation weighting factor, denoted as w_R, is a dimensionless multiplier applied to the absorbed dose from a specific radiation type to derive the equivalent dose, accounting for the relative biological effectiveness (RBE) of different ionizing radiations in inducing stochastic health effects. It adjusts the physical absorbed dose, measured in grays (Gy), to reflect variations in biological damage potential due to differences in linear energy transfer (LET), where high-LET radiations like alpha particles cause denser ionization tracks and greater cellular harm compared to low-LET radiations such as photons. The rationale for w_R centers on RBE values derived from radiobiological studies, emphasizing endpoints like and hereditary effects at low doses, rather than deterministic effects. These factors are established through a combination of and data, epidemiological observations, and biophysical modeling, averaged over human tissues to provide a conservative estimate suitable for radiological protection. In the equivalent dose calculation for protection quantities, w_R scales the to yield results in . The (ICRP) Publication 103 specifies fixed w_R values for most radiation types, with neutrons requiring energy-dependent adjustment. These values represent refinements from prior recommendations, incorporating updated RBE data without altering the core framework for photons, electrons, or heavy ions.
Radiation Typew_R Value
Photons, all energies1
Electrons and muons, all energies1
Protons and charged pions, >2 MeV2
Alpha particles, fission fragments, and heavy ions20
For neutrons, w_R is defined as a continuous function of incident neutron energy E_n (in MeV) to better capture spectral variations in biological effectiveness, replacing the discrete steps of earlier guidelines. The function is piecewise: \begin{align*} & \text{If } E_n < 1: \quad w_R = 2.5 + 18.2 \exp\left( -\frac{(\ln E_n)^2}{6} \right) \\ & \text{If } 1 \leq E_n \leq 50: \quad w_R = 5.0 + 17.0 \exp\left( -\frac{(\ln (2 E_n))^2}{6} \right) \\ & \text{If } E_n > 50: \quad w_R = 2.5 + 3.25 \exp\left( -\frac{(\ln (0.04 E_n))^2}{6} \right) \end{align*} This formulation peaks at approximately 21 near 1 MeV, reflecting enhanced damage from recoils and secondary particles, and approaches 2.5 at very low (<10 keV) or very high (>1 GeV) energies. As of 2025, no revisions to these w_R values have been adopted by the ICRP, though a system-wide review is underway for future recommendations.

Tissue Weighting Factor

The tissue weighting factor, denoted as w_T, represents the fraction of the total stochastic detriment (primarily cancer induction and heritable effects) attributable to the irradiation of a specific tissue or organ T, assuming uniform whole-body exposure. These factors are dimensionless and sum to 1 across all tissues, enabling the calculation of effective dose by weighting the equivalent dose to each organ according to its relative radiosensitivity. In the 2007 recommendations (ICRP Publication 103), the tissue weighting factors were revised based on updated epidemiological data from atomic bomb survivors and other cohorts, emphasizing sex-averaged values derived from reference male and female computational phantoms. The values are applied uniformly for both sexes in general protection scenarios, though sex-specific factors can be used for targeted assessments; no major revisions to these factors have occurred since 2007. Key examples include bone marrow (red blood cells) at 0.12, lungs at 0.12, and the remainder tissues (a group of 13 organs including adrenals, extrathoracic region, gall bladder, heart, kidneys, lymphatic nodes, muscle, oral mucosa, pancreas, prostate, small intestine, spleen, thymus, and uterus/cervix) at 0.12 collectively.
Tissue or Organ GroupTissue Weighting Factor w_T
Bone marrow (red), colon, lung, stomach, breast0.12 each
Remainder tissues (13 specified organs)0.12 (total)
Gonads0.08
Bladder, oesophagus, liver, thyroid0.04 each
Bone surface, brain, salivary glands, skin0.01 each
These factors integrate with radiation weighting factors w_R from the previous subsection to form equivalent doses for each tissue, which are then summed to yield the effective dose. Compared to the 1990 recommendations (ICRP Publication 60), notable changes include an increase in the factor from 0.05 to 0.12, reflecting higher estimated cancer risks, and a decrease in the gonads factor from 0.20 to 0.08 due to revised heritable effects estimates. The remainder tissues' collective weight also rose from 0.05 (for 12 organs) to 0.12 (for 13 organs), better accounting for distributed risks.

Effective Dose Formula

The effective dose E, a protection quantity used to quantify stochastic radiation risks to the whole body, is computed as the double summation over specified tissues T and radiation types R: E = \sum_T w_T \sum_R w_R D_{T,R}, where w_T is the tissue weighting factor, w_R is the radiation weighting factor, and D_{T,R} is the to tissue T from radiation R. This formula integrates the of different radiations and the varying sensitivities of body tissues to produce a single risk-related value in sieverts (Sv). The derivation proceeds in steps from fundamental physical quantities. First, the D_{T,R}, measured in (Gy) as energy deposited per unit mass, quantifies energy absorption but does not account for type differences. Second, the H_T to T adjusts for biological impact by applying w_R: H_T = \sum_R w_R D_{T,R}, expressed in Sv. Third, the effective dose E then weights these equivalent doses by w_T to reflect overall detriment: E = \sum_T w_T H_T, yielding the composite formula above. These steps enable comparison of diverse exposures on a common scale for radiological protection. This framework rests on key assumptions, including the linear no-threshold (LNT) model, which posits that effects like are proportional to dose across all levels without a safe threshold, allowing summation for mixed exposures. Additionally, calculations average over a reference population, typically sex-averaged values, to represent rather than individual-specific doses. For , consider a hypothetical uniform external exposure delivering 0.10 from gamma rays (photons, w_R = 1) to the lungs (w_T = 0.12) and 0.05 from alpha particles (w_R = 20) to red (w_T = 0.12), with negligible doses elsewhere. The to lungs is H_{\text{lungs}} = 1 \times 0.10 = 0.10 , and to marrow is H_{\text{marrow}} = 20 \times 0.05 = 1.00 . The effective dose is then E = (0.12 \times 0.10) + (0.12 \times 1.00) = 0.132 , demonstrating how high-LET radiation amplifies overall despite lower absorbed dose. This example uses w_R and w_T values from established standards but simplifies by ignoring other tissues and sex-averaging.

External Dose Measurement

Ambient Dose Equivalent

The ambient dose equivalent, denoted as H^*(10), is an operational quantity defined as the dose equivalent at a depth of 10 mm in the ICRU sphere resulting from the corresponding expanded and aligned field at a specified point in the actual field. The ICRU sphere is a 30 cm diameter sphere composed of tissue-equivalent material with 1 g/cm³ and elemental composition approximating . This quantity is specifically intended for strongly penetrating and serves as a conservative estimate of the effective dose for external whole-body exposures, particularly from photons, where it approximates the protection quantity by accounting for depth dose in a simplified . In practical applications, H^*(10) is widely used for area monitoring in radiation-controlled workplaces, such as nuclear facilities and environments, to assess potential exposure risks to personnel. It also forms the basis for survey meters and other area dosimeters, ensuring instruments respond appropriately to ambient fields by relating their readings to established coefficients. For instance, factors for survey monitors are determined as N_{H^*} = H^*(10) / M, where M is the instrument reading, facilitating accurate environmental dose assessments. The energy response of H^*(10) is engineered for near-uniformity across relevant spectra: for photons, conversion coefficients from air to H^*(10) remain approximately flat, with a close to 1.20 from 20 keV to 10 MeV, enabling reliable measurements without significant energy dependence in this range. For s, fluence-to-H^*(10) conversion coefficients h^*(10) vary with energy, increasing from low values below 1 keV to a peak around 1 MeV (reaching about 80 pSv·cm² at 1 MeV) before decreasing at higher energies, reflecting the quality factor's modulation by neutron interaction characteristics. Similar overestimations occur for high-energy protons and muons; updated coefficients in ICRU Report 95 address energies up to 10 GeV for better accuracy in such fields. Despite its utility, H^*(10) has limitations, particularly overestimating the effective dose for neutrons in high-energy ranges above 10 MeV or in fields dominated by high-energy charged particles like protons or muons, where the operational definition based on expanded fields does not fully capture anisotropic or secondary particle contributions. This can lead to conservative but potentially excessive assessments in or environments.

Directional Dose Equivalent

The directional dose equivalent, denoted H'(d, \alpha), is an operational quantity in that quantifies the dose equivalent at a specified depth d in along a given of incidence \alpha. It is defined as the dose equivalent produced at a point within the ICRU (a 30 cm filled with -equivalent material of 1 g/cm³) by the corresponding expanded and aligned from the actual anisotropic . The unit is the sievert (Sv). Common depths include d = 0.07 mm for shallow dose assessment, corresponding to H'(0.07, \alpha), and d = 10 mm for deep dose, corresponding to H'(10, \alpha). The shallow version approximates the equivalent dose to the skin or lens of the eye in oriented fields, while the deep version serves as a conservative surrogate for the effective dose from external exposure. This directionality distinguishes it from isotropic quantities like the ambient dose equivalent, making it suitable for scenarios with known radiation direction. The quantity is applied in monitoring anisotropic external radiation fields, such as scattered from accelerators or facilities, where the incident direction can be specified. Conversion coefficients from fluence to H'(d, \alpha) are provided in ICRP Publication 116 for various radiation types and energies to facilitate practical measurements. For calibration in directional fields, the ICRU sphere is used; the slab phantom is employed for personal dose equivalents.

Personal Dose Equivalent

The personal dose equivalent, denoted as H_p(d), is an operational quantity defined by the (ICRP) as the dose equivalent in ICRU four-element at a depth d below a specified point on the , calculated using a slab that simulates the human . This is a rectangular prism measuring 30 cm × 30 cm × 15 cm, composed of ICRU tissue with a of 1 g cm⁻³, to account for the and scatter from the body during external . The most commonly used variants are H_p(10), which estimates the dose to tissues at a 10 mm depth for penetrating radiation such as photons and neutrons, and H_p(0.07), which measures the dose at a 0.07 mm depth for superficial effects like skin dose from beta particles or low-energy photons. A key feature of the personal dose equivalent is its inclusion of the backscatter factor, which represents the increase in dose due to radiation reflected from the body surface back toward the dosimeter. For photon radiation in the energy range above 100 keV, this factor typically increases the measured dose by approximately 30% compared to measurements in free air, as the body's tissues reflect a portion of the incident radiation, enhancing the local dose at the point of measurement. This correction is embedded in the conversion coefficients provided by ICRP Publication 74, ensuring that H_p(d) more accurately reflects the dose to the wearer than field quantities alone. The personal dose equivalent thus builds on the directional dose equivalent by incorporating body scatter effects for individual monitoring scenarios. In practice, the personal dose equivalent is primarily applied in personal dosimetry systems, such as thermoluminescent dosimeter (TLD) badges or optically stimulated luminescence (OSL) dosimeters worn by radiation workers to track cumulative exposure. These devices are calibrated to read H_p(10) and H_p(0.07), enabling the estimation of individual doses in occupational settings like nuclear facilities, medical radiology, and . Annual monitoring is standard for workers likely to exceed 10% of regulatory dose limits, with badges exchanged periodically to integrate exposure over time and ensure compliance with protection standards. For relating personal dose equivalent to protection quantities, ICRP provides approximate conversion factors from H_p(10) to effective dose, particularly for external photon exposures where H_p(10) serves as a conservative overestimate of effective dose in anterior-posterior geometries. These factors, derived from simulations in ICRP Publication 116, vary by radiation type and energy but generally show H_p(10) approximating effective dose within 20-30% for broad-beam fields, allowing dosimetric readings to inform risk assessments without full phantom calculations. For neutrons and other particles, specific coefficients adjust H_p(10) to better align with organ-equivalent doses.

Instrumentation Response

Instrumentation in is calibrated to operational quantities such as the ambient dose equivalent H^*(10) and personal dose equivalent H_p(10), expressed in sieverts (), to approximate protection quantities for monitoring purposes. typically employs standard sources like cesium-137 (Cs-137) for photons and americium-beryllium (Am-Be) for s, ensuring to or standards such as those defined in ISO 4037. For instance, Cs-137 sources, emitting gamma rays at 662 keV, are used to irradiate instruments in controlled fields, with the reference dose determined via air measurements converted to H^*(10) using established coefficients (e.g., H^*(10)/K_a = 1.20 Sv·⁻¹). Am-Be sources provide a with a mean of about 4.4 MeV, calibrated similarly for neutron fields to match H_p(10) on phantoms like the ICRU slab. Common types of detectors include ionization chambers, thermoluminescent dosimeters (TLDs), and optically stimulated luminescence (OSL) dosimeters. Ionization chambers, often used in survey meters, directly measure ionization current proportional to absorbed dose, suitable for real-time monitoring of H^*(10). TLDs, typically based on lithium fluoride (LiF), accumulate dose over time and are read via thermoluminescence, covering ranges from 0.1 mSv to 10 Sv for H_p(10). OSL dosimeters, using aluminum oxide (Al₂O₃:C), offer similar ranges (10 µSv to 10 Sv) with optical readout, providing advantages in reusability and lower detection limits. These devices are calibrated on phantoms (e.g., PMMA slabs for H_p(10)), where backscatter effects are included via the phantom setup, ensuring response to the defined depths of 10 mm. Response functions of these instruments account for energy and angular dependencies to approximate sievert-based quantities accurately. Energy dependence is critical; for example, electronic personal dosimeters (EPDs) must maintain response within ±20% over 30 keV to 1.3 MeV for photons, while OSL dosimeters exhibit flat response from 5 keV to 40 MeV. Angular response for survey meters is evaluated up to ±60° or ±80° from normal incidence, ensuring isotropic behavior in varied fields, as per ISO standards. Conversion from raw detector signals (e.g., counts or charge) to involves applying calibration factors, such as H = h \cdot N \cdot M, where h is the conversion coefficient, N the reading, and M any corrections for environmental factors. Uncertainties in these measurements arise from factors like energy spectrum variations, scatter, and field non-uniformity, with typical values of ±20-30% for operational quantities under conditions using survey meters. For personal dosimeters, uncertainties are around ±10% at 95% confidence, but can reach ±100% in workplace scenarios due to unknown field characteristics. These uncertainties highlight the approximate nature of operational quantities, emphasizing the need for regular and performance testing.

Recent Developments

In 2024, ICRU Report 95 proposed revisions to operational quantities for external to improve alignment with quantities. Key changes include redefining H*(10), H'(d, α), and H_p(d) as products of air or fluence with appropriate factors at a point in air or on a surface, using an updated ICRU computational , and providing coefficients for particles up to 10 GeV. These updates address limitations in high-energy fields and are under consideration by ICRP for adoption in radiological standards as of 2025.

Internal Dose Assessment

Committed Effective Dose

The committed effective dose quantifies the total effective dose resulting from the incorporation of radionuclides into the body, projected over a specified integration period following intake. It represents the sum of the products of the committed equivalent doses to specified tissues or organs, H_T(\tau), and their respective tissue weighting factors, w_T, such that E(\tau) = \sum_T w_T H_T(\tau). This integration time \tau is 50 years for adults and extends to age 70 for children, capturing the long-term risk from internal emitters. Intake of radionuclides occurs primarily through of aerosols or gases, of contaminated or , and to a lesser extent, through or wounds, with the activity intake denoted as I in becquerels (). The committed effective dose is derived by applying biokinetic models to model radionuclide uptake, distribution, retention, and excretion in reference individuals, as established by the (ICRP). These models account for physiological processes specific to each and exposure route. Recent updates in the ICRP Environmental Intakes of Radionuclides series (e.g., Publication 158, 2024) provide revised age-specific coefficients aligned with updated biokinetics and tissue weighting factors from Publication 103 (2007). Dose coefficients, denoted h_T for committed equivalent dose to tissue T per unit intake or e(50) for committed effective dose per unit intake, are computed from these biokinetic and dosimetric data. For instance, the committed effective dose coefficient for ingestion of by an adult member of the public is approximately $1.6 \times 10^{-8} / (as of 2024), predominantly due to uptake in the thyroid gland. These coefficients enable straightforward calculation of E(\tau) = e(50) \times I, facilitating assessments in occupational and public exposure scenarios. Distinctions between acute and intakes influence assessment but not the core definition of committed effective dose, which applies to each identifiable intake event. For acute intakes, a single E(\tau) is computed based on the instantaneous activity incorporated. In exposure scenarios, involving repeated or continuous intakes, the total committed effective dose is the sum of individual E(\tau) values for each intake over the relevant period, often using time-integrated intake rates.

Integration Over Time

In internal dosimetry, the effective dose rate Ė(t) represents the time-dependent to the whole body following the of radionuclides, arising from their within organs and tissues as influenced by biokinetic processes such as uptake, translocation, and . This rate varies over time due to the combined effects of physical decay (characterized by radionuclide-specific half-lives) and biological elimination, which determine the amount of activity present in target tissues at any moment post-. The effective dose, which quantifies the total internal dose attributable to a single , is obtained by integrating the effective over a specified following . For adults, this extends from the time of intake to 50 years later, effectively capturing the long-term dose accumulation while truncating at to ensure practicality; for children, it extends to 70 years to account for longer remaining lifespan. Mathematically, this is expressed as: E(\tau) = \int_0^\tau \dot{E}(t) \, dt where \tau is the integration period (50 years for adults), and \dot{E}(t) incorporates tissue-specific contributions weighted by and weighting factors. To compute these quantities, organ retention functions f_T(t) describe the of the systemic activity retained in T at time t after entry into the , typically modeled as a sum of terms to reflect multi-compartmental biokinetics: f_T(t) = \sum_i a_i e^{-\lambda_i t} Here, a_i are fractional coefficients summing to 1, and \lambda_i = \lambda_{r,i} + \lambda_{b,i} combines the physical decay constant \lambda_r with biological removal rates \lambda_b for each compartment i. These functions enable the derivation of time-integrated activity and subsequent dose coefficients used in practice. Updated biokinetic parameters in recent ICRP publications (e.g., Occupational Intakes series, 2016–2017) refine these retention functions for accuracy. The nature of the isotope significantly affects the integration outcome. For short-lived radionuclides, such as (physical half-life of 8 days), the dose rate peaks rapidly post-intake and decays quickly, with nearly all committed dose delivered within weeks due to swift physical dominating over biological retention. In contrast, for long-lived isotopes like (physical half-life of 30 years), the dose accumulates gradually over decades, as the integration period captures a substantial portion of the physical while biological retention—modeled with components of about 0.25 days and 70 days half-life—prolongs systemic exposure beyond the physical half-life alone. This distinction underscores the importance of the 50-year truncation, which conservatively includes most relevant dose for such nuclides without extending indefinitely.

Biokinetic Models

Biokinetic models in describe the uptake, distribution, retention, and excretion of within the following internal intake, enabling the estimation of time-integrated dose to organs and tissues. These models are physiological representations that account for biological processes such as from entry sites, transport via blood, and accumulation in target organs. Developed primarily by the (ICRP), they form the basis for calculating committed internal doses, integrating radionuclide behavior over periods like 50 years for adults or until age 70 for children. The Occupational Intakes of Radionuclides series (Publications 130–137, 2016–2017) and Environmental Intakes series (e.g., Publication 158, 2024) provide updated models and coefficients. The ICRP Human Respiratory Tract Model (HRTM), introduced in Publication 66, specifically addresses as a primary route by modeling particle deposition, , and into blood across respiratory regions. The tract is divided into the extrathoracic region (), comprising ET1 (anterior nasal passages and mouth) and ET2 (posterior nasal passages, , and ), the bronchial region (: bronchi), bronchiolar region (bb: terminal bronchioles), and alveolar-interstitial region (AI: alveoli and associated interstitium). Deposition efficiency varies with particle aerodynamic diameter (typically 0.001–20 μm): particles larger than 5 μm predominantly deposit in ET1 and via inertial impaction, with up to 50% of ET1 deposits cleared directly to the environment; particles of 1–5 μm settle in and bb through sedimentation and impaction, with rapid clearance (e.g., 2 hours from ); and ultrafine particles below 1 μm favor AI deposition via , where retention can extend to years in slow-cleared compartments (AI2: ~2 years, AI3: ~20 years). This size-dependent deposition ensures accurate prediction of initial burdens for aerosols with activity median aerodynamic diameters of 1 μm (environmental) or 5 μm (occupational). Once absorbed into the systemic circulation, radionuclide behavior is governed by element-specific biokinetic models that quantify rates between (as the central compartment) and organs such as liver, kidneys, , and . These models use fractional coefficients (e.g., in day⁻¹) to represent uptake from to tissues and back to , tailored to chemical form and . For instance, ICRP Publication 128 compiles such models for key elements in , including rapid uptake of into the (transfer coefficient ~0.3 from ) and strontium-89 retention in via surface-seeking mechanisms. Gastrointestinal absorption models, like those in Publication 100, further specify fractional uptake (f₁ values) ranging from 0.001 for to 1 for cesium, influencing systemic entry from . ICRP biokinetic models incorporate age- and sex-dependent parameters to reflect physiological variations, particularly higher uptake and retention in vulnerable populations. Children exhibit elevated gastrointestinal absorption for elements like (f₁ up to 0.3 vs. 0.15 in adults) and faster turnover, leading to greater skeletal doses; for example, lead models in Publication 72 show 30–50% higher blood retention in infants due to immature barriers. Sex differences arise from variances in masses and hormonal influences, such as lower iron absorption in adult males compared to females, as detailed in Publication 89's . These adjustments ensure dose coefficients scale appropriately, with pediatric models often derived from adult baselines scaled by body weight and maturity. Software tools implement these ICRP models to automate committed dose computations from data or intake scenarios. IMBA (Integrated Modules for Analysis) supports user-defined parameters for HRTM and systemic , calculating organ-specific committed effective doses for over 800 radionuclides while allowing customization of transfer coefficients. Similarly, MONDAL (Monitoring to Dose cALculation support system), developed by Japan's National Institute of Radiological Sciences (now QST), integrates biokinetic simulations for intake assessment, generating retention functions and dose coefficients aligned with ICRP recommendations, particularly for occupational monitoring. Both tools facilitate integration of biokinetic outputs with time-dependent exposure data to derive total internal doses and are compatible with updated ICRP data as of 2024.

Health Effects and Limits

Stochastic Effects

Stochastic effects refer to radiation-induced health outcomes, such as cancer and hereditary disorders, where the probability of occurrence is proportional to the absorbed dose in sieverts, but the severity remains independent of dose level. These effects are characterized by their random nature and lack of a dose threshold, meaning even small exposures carry some risk of manifestation years or decades later. The effective dose, expressed in sieverts, serves as the primary quantity for quantifying and comparing these probabilistic risks across different exposure scenarios. The linear no-threshold (LNT) model underpins for stochastic effects, positing a straight-line relationship between dose and risk probability without a safe threshold. Endorsed in the BEIR VII report, this model extrapolates from high-dose observations to predict low-dose risks, estimating an approximate 5% increase in lifetime fatal cancer risk per sievert of low-linear energy transfer (low-LET) for the general population. This extrapolation assumes risks scale linearly, with adjustments for factors like age, sex, and exposure type, though uncertainties increase at doses below 100 millisieverts. Among sensitive endpoints, exhibits elevated susceptibility, with epidemiological models showing risks detectable around 100 millisieverts, aligning with LNT predictions despite statistical challenges at lower doses. Hereditary effects, involving transgenerational genetic mutations, carry an estimated risk of approximately 0.6% per sievert, though direct human evidence remains limited and primarily inferred from animal data and doubling dose concepts. The epidemiological foundation for these models derives mainly from the Life Span Study of over 120,000 atomic bomb survivors in and , which has tracked excess cancers proportional to dose over decades. Supporting data come from cohorts exposed via medical procedures, such as diagnostic imaging and radiotherapy, confirming stochastic patterns in populations receiving 10-500 millisieverts. These studies collectively validate the LNT framework for sievert-based risk estimation.

Deterministic Effects

Deterministic effects, also referred to as tissue reactions, are radiation-induced injuries to normal tissues and organs that exhibit a clear dose below which no observable occurs. Above this , the severity of the injury increases predictably with higher absorbed doses, measured in sieverts (Sv) for equivalent dose to account for radiation type and biological effectiveness. These effects are distinct from processes because they depend on the depletion of functional cells rather than random genetic alterations, allowing for dose-dependent clinical manifestations in contexts. The underlying mechanisms of deterministic effects primarily involve cell killing through processes such as clonogenic cell death or apoptosis, leading to insufficient repopulation and subsequent tissue dysfunction. This contrasts with stochastic effects, which stem from unrepaired DNA damage causing mutations and probabilistic outcomes like cancer. For instance, in highly radiosensitive tissues, radiation depletes parenchymal cells (e.g., epithelial cells in the skin or intestinal crypts) or damages supportive structures like vascular endothelium, resulting in observable harm only when a critical fraction of cells is lost. Biological modifiers, including repair mechanisms and tissue-specific responses, can influence the expression of these effects post-exposure. Prominent examples include skin , where acute exposures of 2-6 cause transient reddening starting at around 2 and more pronounced reactions at 6 due to vascular damage and inflammatory responses. (ARS) emerges in whole-body exposures exceeding 1 , encompassing hematopoietic, gastrointestinal, and neurovascular subsyndromes with increasing lethality above 2-10 from widespread cell depletion in , gut, and . opacification leading to cataracts has a of 0.5-2 for acute doses to the eye, involving damage to epithelial cells and fiber disruption, though individual variability exists. Dose-rate plays a critical role in modulating deterministic effects, as protracted exposures allow time for sublethal damage repair and repopulation, thereby raising effective thresholds and reducing severity compared to acute . For example, exposures may tolerate up to 5 without cataracts, while skin and hematopoietic tissues show enhanced recovery during fractionated dosing. This sparing effect underscores the importance of exposure timing in assessing risks for protection quantities like .

Regulatory Dose Limits

The (ICRP) establishes fundamental dose limits in sieverts to safeguard workers and the public from exposure in planned situations. For occupational exposure, the effective dose limit is 20 mSv per year, averaged over 5 consecutive years, with no single year exceeding 50 mSv; for members of the public, it is 1 mSv per year. These limits encompass the total effective dose, which sums contributions from both external irradiation (e.g., measured via personal dosimeters) and internal contamination (e.g., from or , assessed using biokinetic models). In addition to effective dose, ICRP specifies separate equivalent dose limits for radiosensitive tissues to prevent deterministic effects. The equivalent dose limit to the of the eye is 20 mSv per year, averaged over 5 years, with no single year exceeding 50 mSv for workers, and 15 mSv per year for the public; for , it is 500 mSv per year (averaged over any 1 cm² for any part of the body) for workers and 50 mSv per year for the public. These tissue-specific limits complement the effective dose by addressing localized exposures that could lead to tissue reactions. A core principle underlying these limits is the ALARA (As Low As Reasonably Achievable) optimization process, which requires keeping doses below the limits through , administrative measures, and protective equipment, while balancing economic and social factors. These limits are designed to minimize risks of effects, such as cancer, while ensuring deterministic effects are avoided. Many national and international regulations align with ICRP recommendations; for instance, the (IAEA) endorses these limits in its Basic Safety Standards (GSR Part 3, 2014), with no fundamental changes to the core framework since ICRP Publication 103 (2007), except for the reduced lens of eye limit in 2012.

Practical Examples

Common Dose Levels

The sievert (Sv) quantifies the effective dose of , providing context for health risks when compared to typical exposure levels from natural, , and accidental sources. These doses are expressed in millisieverts (mSv; 1 mSv = 0.001 Sv) for everyday scenarios and sieverts for higher acute exposures, helping to illustrate the scale relative to regulatory limits like the 1 mSv annual public exposure guideline from the . Natural , arising from cosmic rays, terrestrial sources, and internal radionuclides like , delivers a global average annual effective dose of approximately 2.4 mSv, though this varies by location due to factors such as soil composition and altitude. In regions with elevated concentrations, such as certain mining areas or geologically active zones, annual doses can reach up to 10 mSv, primarily from inhalation of radon decay products. Medical procedures contribute variably to individual doses, with a standard chest computed tomography (CT) scan delivering an effective dose of about 7 mSv, equivalent to roughly three years of natural background exposure. Routine dental X-rays, assuming 2-4 intraoral images per year, result in a negligible annual effective dose of approximately 0.01 mSv. Notable accidental exposures highlight higher dose ranges; during the 1986 Chernobyl nuclear accident, acute effective doses to initial responders and cleanup workers (liquidators) ranged from less than 0.1 for most cleanup workers to over 6 for some initial responders, with averages around 0.12 across over 500,000 participants, leading to in cases exceeding 1 . In contrast, public exposures from the 2011 Daiichi accident were much lower, with lifetime effective doses for residents in affected prefectures estimated at less than 10 m, primarily from external gamma and minor internal contamination. Over a typical lifespan of 70 years, cumulative natural accumulates to about 100-200 mSv, underscoring that most individuals encounter low-level routinely without exceeding safe thresholds.
SourceTypical Effective DoseNotes
Global natural (annual)2.4 mSvIncludes cosmic, terrestrial, and internal sources; varies by geography.
High- areas (annual)Up to 10 mSvMainly from in homes or workplaces.
Chest ~7 mSvSingle procedure; diagnostic imaging.
Annual dental X-rays~0.01 mSvRoutine checkups with 2-4 images.
workers (acute)<0.1 to >6 SvInitial responders and liquidators; average 0.12 Sv.
public (lifetime)<10 mSvEvacuated and nearby residents.
Lifetime natural 100-200 mSvOver 40-80 years at average rates.

Dose Rate Comparisons

The dose rate, expressed in sieverts per unit time (typically per hour), quantifies the rate at which effective dose is delivered from sources, allowing comparisons of exposure intensity across everyday, occupational, and accidental scenarios. This metric is crucial for assessing relative risks without integrating over exposure duration. Natural , arising from cosmic rays, terrestrial sources, and , exposes individuals to an average of approximately 0.3 μSv per hour in the United States. This baseline level varies by location but provides a reference for negligible exposure. In contrast, cosmic radiation during commercial at typical cruising altitudes (around 10 km) elevates the to 5–10 μSv per hour, primarily due to galactic cosmic rays and solar particles, with higher values at polar routes or during . Medical procedures, such as those in or , can produce significantly higher dose rates to the patient, reaching up to 50 mSv per hour for prolonged or complex imaging, though typical rates for standard procedures are lower, around 8–10 mSv per hour of beam-on time. Extreme dose rates occurred during the 1986 Chernobyl accident, where initial levels near the exposed reactor core were estimated at up to 300 per hour, posing immediate lethal risks to unprotected personnel within minutes.
SourceTypical Dose RateContext
Natural Background~0.3 μSv/hGlobal average exposure
5–10 μSv/hCruising altitude, commercial flights
(Medical)Up to 50 mSv/hPatient during interventional procedures
Chernobyl Core (1986)Up to 300 Sv/hImmediately post-explosion

Occupational and Public Exposure

In occupational settings, workers typically receive an average annual effective dose of around 1 mSv, with the majority below 5 mSv, as reported by the International Atomic Energy Agency's Information System on Occupational Exposure (ISOE) programme based on 2017 data from facilities worldwide. This is well below regulatory limits of 20-50 mSv per year, reflecting optimized protection measures such as shielding and . Similarly, crew members experience elevated cosmic radiation exposure due to high-altitude flights, with annual effective doses ranging from 2-5 mSv for frequent long-haul routes, particularly polar paths, according to IAEA assessments. For the general public, additional exposure near nuclear power plants is minimal, typically less than 0.1 mSv per year from routine operations, as determined by U.S. Nuclear Regulatory Commission monitoring data showing average doses of about 0.0001 mSv annually within 50 miles of a site. Public exposure to cosmic rays also varies geographically and with altitude; at sea level, it averages 0.38 mSv per year globally, increasing to over 1 mSv at higher elevations or latitudes, per IAEA estimates. In emergency scenarios, such as the 2011 Fukushima Daiichi accident, (TEPCO) workers received cumulative effective doses up to 678 mSv for a few individuals, though most stayed below 100 mSv, with monitoring involving electronic personal dosimeters for external exposure and whole-body counters for internal contamination, as detailed in IAEA reports. These monitored personal dose equivalents, Hp(10), provide a conservative estimate of effective dose for external , generally exceeding the true effective dose E to ensure safety margins in , according to IAEA dosimetry guidelines.

History

Origin and Naming

The sievert (Sv), the for and effective dose in , is named after (1896–1966), a pioneering renowned for his foundational work in and radiological safety. The name was formally adopted in 1979 by the 16th General Conference on Weights and Measures (CGPM), following recommendations from the International Commission on Radiation Units and Measurements (ICRU), to honor Sievert's lifetime contributions to understanding and mitigating the biological effects of . This adoption aligned with broader efforts to standardize quantities within the (SI), replacing non-coherent legacy units. Prior to 1979, radiation dosimetry relied on units such as the (R) for exposure, the for absorbed dose, and the for dose equivalent, which were based on the centimeter-gram-second (CGS) system and lacked direct compatibility with SI base units like the joule and . These units, while practical, created inconsistencies in international scientific communication and applications, prompting the ICRU and (ICRP) to advocate for SI-derived alternatives to ensure coherence and precision in measuring risks to human health. The sievert addressed this by defining dose equivalent as absorbed per unit mass (joules per ), weighted for biological effectiveness. The concept of dose equivalent, for which the sievert later served as , was first formalized in the ICRU's Report 19, Radiation Quantities and Units (1971), with further elaboration in its 1973 supplement specifically on dose equivalent. Sievert's own innovations, including the development of the capacitor-type (known as the Sievert chamber) in the 1920s and standardization of the skin erythema dose, laid critical groundwork for accurate and , influencing these ICRU definitions. For context, 1 Sv equals 100 , maintaining numerical continuity with the prior unit during the transition.

Evolution of Definitions

The evolution of the sievert as a unit for effective dose began with the (ICRP) Publication 26 in 1977, which introduced the concept of effective dose equivalent to quantify stochastic risks across the body. This incorporated radiation weighting factors (w_R) to account for differences in biological effectiveness among radiation types and tissue weighting factors (w_T) to reflect varying sensitivities of organs and s, replacing earlier, less comprehensive approaches to whole-body dose . The sievert was subsequently adopted as the unit for these quantities in 1979. In 1990, ICRP Publication 60 refined these concepts by updating the w_R values, particularly for neutrons, to better align with emerging data on , and it phased out the use of the quality factor () in favor of the more standardized w_R for protection purposes. These changes aimed to simplify while maintaining conservatism in risk estimation for mixed radiation fields. ICRP Publication 103 in 2007 further evolved the framework by refining the w_T values based on updated epidemiological evidence, such as increasing the remainder tissue weighting from 0.30 to 0.12 distributed across additional organs, including the addition of the to the remainder category for more accurate representation of cancer risks. Although some proposals for operational modifications to dose quantities were considered during this revision, they were ultimately rejected to preserve compatibility with existing regulatory systems. As of 2025, no further updates to the core definitions of the sievert or its associated weighting factors have been issued by the ICRP, despite ongoing discussions regarding the linear no-threshold (LNT) model for low-dose risks; the unit and its conceptual basis remain unchanged from the recommendations.

Key Publications and Revisions

The sievert (Sv) was formally adopted as the special name for the SI unit of dose equivalent by the 16th General Conference on Weights and Measures (CGPM) in , equivalent to one joule per kilogram (J/kg), to quantify the biological effects of on human tissue. This adoption followed the International Commission on Radiation Units and Measurements' (ICRU) introduction of the dose equivalent concept in 1971 and the International Commission on Radiological Protection's (ICRP) early use of the quantity in joules per kilogram in its foundational recommendations. ICRP Publication 26 (1977) marked the seminal introduction of protection quantities using the dose equivalent and effective dose equivalent concepts in radiological protection, defining the dose equivalent as the product of absorbed dose and a quality factor to account for radiation type, and the effective dose equivalent as a weighted sum across tissues to estimate stochastic risk. This publication established the framework for these protection quantities in J/kg (later sieverts), shifting from earlier concepts like the rem and emphasizing detriment from cancer and hereditary effects, with a nominal risk coefficient of 1.25 × 10^{-2} Sv^{-1} for fatal cancer (part of total detriment of 1.65 × 10^{-2} Sv^{-1}). (Note: Full text access via ICRP archives.) Subsequent revisions refined these definitions without altering the sievert unit itself. ICRP Publication 60 (1990) replaced effective dose equivalent with effective dose, incorporating updated tissue weighting factors based on revised risk estimates from atomic bomb survivors and other data, increasing the overall detriment coefficient to 5.0 × 10^{-2} Sv^{-1} for the whole population. This update prioritized sex-averaged risks and separated deterministic effects, maintaining the sievert for summation across exposure scenarios. ICRP Publication 103 (2007) further evolved the framework by revising tissue weighting factors—e.g., elevating those for lungs (0.12) and (0.12) while reducing for gonads (0.08)—to better reflect epidemiological , with the effective dose now serving optimization in planned exposures. It reaffirmed the sievert's role in limiting risks, with total detriment of approximately 5% per . More recent guidance, such as ICRP Publication 147 (2021), clarifies the application of equivalent and effective doses in sieverts for , addressing ambiguities in operational quantities and emphasizing their non-use for individual in contexts. These publications collectively underscore the sievert's enduring utility in balancing protection against varied sources.

Equivalence to Rem

The rem (roentgen equivalent man) is a legacy non-SI unit for measuring dose equivalent, developed to quantify the biological impact of on human tissue in a manner parallel to the modern sievert. Introduced by the (ICRP) in 1954, the rem accounted for the varying effectiveness of different radiation types by weighting , addressing limitations in earlier units like the that focused solely on exposure. This unit emerged during a period of post-World War II advancements in , where the need for a biologically weighted measure became evident amid growing concerns over activities. The precise equivalence between the rem and sievert was established with the adoption of the (SI) in the 1970s, defining 1 rem = 0.01 exactly, or conversely, 1 = 100 rem. This direct scalar relationship simplifies conversions across scales; for instance, 100 millirem (mrem) equals 1 millisievert (mSv), and 5 rem equals 0.05 . The sievert, named after physicist Rolf Sievert and based on joules per (J/kg), supersedes the rem as the SI-derived unit for equivalent and , emphasizing absorbed energy weighted by radiation type and tissue sensitivity. Despite international efforts to standardize on units, the persists in U.S. regulatory frameworks, such as those from the (NRC), where dose limits for workers and the public are often expressed in alongside equivalents. Organizations like the (IAEA) and the International Bureau of Weights and Measures (BIPM) advocate for the exclusive use of the sievert to align global practices, reduce conversion errors, and facilitate international collaboration in radiation safety. This promotion reflects broader adoption policies, though the 's entrenched role in American standards delays a full phase-out.

SI Usage Guidelines

The sievert (Sv) is a derived unit in the (SI), defined as the special name for the unit of dose equivalent, equivalent to one joule per kilogram (J/), making it coherent with the SI base units of mass (, kg) and energy (joule, J). This definition ensures consistency in measurements, where the sievert quantifies the biological effectiveness of absorbed doses. The International Bureau of Weights and Measures (BIPM) recommends using the sievert exclusively for equivalent dose, effective dose, and operational dose quantities in SI-compliant reporting to maintain uniformity across scientific and regulatory contexts. In reporting doses, SI guidelines specify expressing values as an Arabic numeral followed by a space and the unit symbol (e.g., 2.4 ), with SI prefixes applied for smaller magnitudes to enhance readability. For low-level exposures, such as natural , doses are typically reported in using prefixes like millisievert (, 10^{-3} Sv) or microsievert (μSv, 10^{-6} Sv), for example, annual public exposure around 2400 μSv. Higher precision requires decimal places when necessary, but suffice for approximate or rounded values below 1 to avoid implying unwarranted accuracy. Unit symbols must be upright (Sv, not italicized) and not abbreviated further, with plural forms identical to singular (e.g., 1 Sv, 10 Sv). International standards, such as ISO 8529, provide protocols for calibrating measuring devices in terms of the sievert, particularly for fields and dosimeters used in protection-level monitoring. Part 3 of ISO 8529 outlines procedures for calibrating area and personal dosimeters with reference radiations, ensuring to SI units and specifying ambient dose equivalent in for operational quantities. These standards emphasize avoiding mixed units, such as combining sievert with non-SI equivalents like in the same report, to promote SI coherence; conversions should be provided separately if non-SI units are referenced for legacy compatibility. Common errors in sievert usage include misapplying SI prefixes, such as using them inconsistently (e.g., "mSv" for 10^{-3} but omitting for larger scales), or formatting issues like attaching units directly to numbers without a space (e.g., 10Sv instead of 10 Sv). Another frequent mistake is confusing the sievert symbol (Sv) with non-radiation notations, such as velocity units (m/s), leading to erroneous interpretations in multidisciplinary documents; always contextualize as the radiation dose unit. To prevent such issues, adhere strictly to BIPM and NIST conventions for symbol rendering and unit coherence.

Broader Ionizing Radiation Quantities

The sievert (Sv) is a unit within a broader framework of quantities used to quantify ionizing radiation effects, ranging from initial exposure in the environment to biological impacts on the human body. This hierarchy begins with measures of radiation interaction with air and matter, progressing to quantities that account for radiation type and tissue sensitivity, ultimately informing radiological protection standards. Exposure quantifies the ionization produced by photons (such as X-rays or gamma rays) in air, serving as an early step in assessing fields. The traditional unit for is the (R), defined as the amount of that produces ions carrying 0.000258 coulombs of charge per of dry air under standard conditions. This quantity does not directly measure energy absorption but provides a basis for estimating subsequent effects in . Following exposure, kerma (kinetic energy released per unit mass) describes the energy transferred from indirectly ionizing radiation (like photons) to charged particles in a medium, such as air or tissue. Air kerma, often used in operational dosimetry, links exposure to potential energy deposition and is expressed in grays (Gy), helping to bridge environmental measurements to absorbed doses in materials. Absorbed dose, measured in grays (Gy), represents the energy deposited by any ionizing radiation per unit mass in a specified material, such as human tissue, and is fundamental to understanding local energy transfer. One gray equals one joule per kilogram. From absorbed dose, the chain advances to equivalent dose, calculated by multiplying absorbed dose by a radiation weighting factor (w_R) to account for the relative biological effectiveness of different radiation types; this yields the sievert as the unit for equivalent dose, focusing on stochastic risks to specific organs. Effective dose, also in sieverts, extends equivalent dose by applying tissue weighting factors (w_T) to sum risks across the whole body, enabling comparisons of overall health impacts from varied scenarios. Thus, the progression—exposure (R) to (Gy) to (Gy) to (Sv) to effective dose (Sv)—provides a comprehensive pathway from source interactions to protective dose limits. Upstream in this framework, activity, measured in , quantifies the source strength as the number of disintegrations per second, serving as the origin for exposures that lead to the aforementioned dose quantities. One equals one disintegration per second.

References

  1. [1]
    § 20.1004 Units of radiation dose. | Nuclear Regulatory Commission
    Sievert is the SI unit of any of the quantities expressed as dose equivalent. The dose equivalent in sieverts is equal to the absorbed dose in grays multiplied ...
  2. [2]
    Radiation Terms and Units | US EPA
    Apr 8, 2025 · The units for effective dose are sievert (Sv, international unit) and rem (rem, U.S. unit). Effective dose indicates radiation health effects ...
  3. [3]
    Radiation Quantities and Units, Definitions, Acronyms - NCBI - NIH
    sievert (Sv) The SI unit of any of the quantities expressed as dose equivalent. The dose equivalent in sieverts is equal to the product of the absorbed dose in ...
  4. [4]
    Radiation Quantities and Units | FDA
    Dec 5, 2017 · The unit for the effective dose is also the sievert (Sv). Quantities specific to CT - A number of special dose quantities have been developed to ...
  5. [5]
    Various Units of Dose - Animations
    The sievert has replaced the "rem" unit since 1975 (1 sievert = 100 rems; rad was also replaced with Gray, 1 Gy = 100 rads). Replay animation.
  6. [6]
    Sievert (Sv) - Nuclear Regulatory Commission
    Sievert (Sv). The international system (SI) unit for dose equivalent equal to 1 Joule/kilogram. 1 sievert = 100 rem. Named for physicist Rolf Sievert. Page ...<|control11|><|separator|>
  7. [7]
    Rolf Maximilian Sievert (1896-1966): father of radiation protection
    Rolf Maximilian Sievert (1896-1966): father of radiation protection. ... Biography; Historical Article; Portrait. MeSH terms. History, 19th Century ...
  8. [8]
  9. [9]
    [PDF] SI Brochure - 9th ed./version 3.02 - BIPM
    May 20, 2019 · The SI brochure, published by BIPM, is about the International System of Units (SI), and contains decisions and recommendations concerning ...
  10. [10]
    Recommendation 2 of the 91st CIPM (2002) - BIPM
    the current definition of the SI unit of dose equivalent (sievert) includes a factor "N" (product of any other multiplying factors) stipulated by the ...
  11. [11]
  12. [12]
    ICRP
    ### Summary of Units of Dose Equivalent in ICRP Publication 103
  13. [13]
  14. [14]
    Gray (Gy) | Nuclear Regulatory Commission
    One gray (Gy) is the international system of units (SI) equivalent of 100 rads, which is equal to an absorbed dose of 1 Joule/kilogram. An absorbed dose of 0. ...
  15. [15]
    Units of ionising radiation measurement | ARPANSA
    Absorbed Dose. Radiation exposure is measured in an international (SI) unit called the gray (Gy). The radiation exposure is equivalent to the energy ...
  16. [16]
    Relative biological effectiveness (RBE), quality factor (Q), and ...
    The sum of the organ-equivalent doses weighted by the ICRP organ-weighting factors, wT, is termed the effective dose, E. Measurements can be performed in terms ...
  17. [17]
    Absorbed, Equivalent, and Effective Dose - ICRPaedia
    ICRP Publication 103 paragraph 125​​ The unit of effective dose is J kg-1 with the special name sievert (Sv). The unit is the same for equivalent dose and ...Missing: exact | Show results with:exact
  18. [18]
    Radiation weighting factors - ENS - European Nuclear Society
    Radiation weighting factors ; Photons, all energies. 1 ; Electrons, myons, all energies. 1 ; Protons and charged pions. 2 ; Alpha particles, fissionXSee 'nuclear ...
  19. [19]
    [PDF] IAEA Safety Glossary
    This series covers nuclear safety, radiation safety, transport safety and waste safety. The publication categories in the series are Safety Fundamentals,.
  20. [20]
    [PDF] IAEA STYLE MANUAL FOR PUBLICATIONS AND DOCUMENTS IN ...
    Nov 21, 2002 · This updated version of the 1989 edition of the IAEA Style Manual for Publications and. Documents in English is available on OASIS as well ...
  21. [21]
    [PDF] Chapter 3. Fundamentals of Dosimetry
    is simpler to define radiative kerma as the difference: K rad. = K–K ... • ATTIX, F.H., “Introduction to radiological physics and radiation dosimetry ...
  22. [22]
    NIST: X-Ray Mass Attenuation Coefficients - Section 3
    As discussed in depth by Carlsson (1985), kerma has been defined (ICRU Report 33, 1980) as (and is an acronym for) the sum of the kinetic energies of all those ...
  23. [23]
    Radiation: Ionizing radiation - World Health Organization (WHO)
    Oct 26, 2020 · The international (SI) unit of measure for an absorbed dose is the gray (Gy), which is defined as 1 joule of energy deposited in 1 kilogram of ...
  24. [24]
    ICRU Report 95, Operational Quantities for External Radiation ...
    Operational, measurable, quantities for external radiation protection complement the protection quantities, which are,by their nature, not measurable.Missing: spheres | Show results with:spheres
  25. [25]
  26. [26]
    Operational quantities and new approach by ICRU
    Mar 15, 2016 · ICRU developed a set of operational dose quantities for use in radiation measurements for external exposure that can assess the protection quantities.
  27. [27]
    ICRU sphere - ICRPaedia
    Sphere of 30 cm diameter made of ICRU tissue. The ICRU sphere is used to define the operational quantities for area monitoring. Retrieved from "http ...
  28. [28]
  29. [29]
    Effective dose - ICRPaedia
    Effective dose is calculated as: E = \sum\limits_T w_T \cdot [\frac{H_T^M + H_T^F}{2}]. where H_T^M and H_F^M are the equivalent doses to the tissues or ...
  30. [30]
    [PDF] AMBIENT DOSE EQUIVALENT H*(d) - INIS-IAEA
    The “ambient dose equivalent”, H*(d), at a point in a radiation field is the dose equivalent that would be produced by the corresponding expanded and aligned ...
  31. [31]
    [PDF] Dosimetric Quantities and Units. - Nuclear Regulatory Commission
    Oct 25, 2010 · Since 1 eV equals 1.6 x 10-19 joules, an exposure of one roentgen equates to an absorbed dose in air of 0.0088 J/kg or 0.0088 gray.
  32. [32]
  33. [33]
    Ambient dose equivalent monitoring in the vicinity of a nuclear ...
    Area dosemeters, which are used to estimate the effective dose by ambient dose equivalent measurements in the environment, are employed in both official and ...
  34. [34]
    [PDF] CHAPTER 4. RADIATION MONITORING INSTRUMENTS
    The calibration factor in terms of the ambient dose equivalent, NH*, for the survey monitor is determined from the equation: NH* = H*(10)/M. 4.3.9. Properties ...
  35. [35]
    [PDF] The Use of Dosimetric Quantities in Radiological Protection ... - ICRP
    Apr 14, 2005 · In the calculation of effective dose radiation weighting factors, wR, are used to allow for the varying effectiveness of different radiations.
  36. [36]
    [PDF] The ICRU proposal for new operational quantities for ... - Hal-CEA
    Jun 23, 2023 · Fluence to ambient dose (equivalent) conversion coefficients h* and h*(10) for neutrons above 1keV (left- hand scale) and response functions the ...
  37. [37]
    [PDF] New Operational Quantities for Radiation Protection by ICRU and ...
    In. 2020, ICRU and ICRP have recommended new operational quantities for external radiation with a definition close to the one of effective dose, and published ...
  38. [38]
    Directional dose equivalent - ICRPaedia
    The directional dose equivalent is one of the operational quantities defined for use in area monitoring against external exposures.Missing: 10 cm
  39. [39]
    Directional Dose Equivalent - H'(d,Ω) | nuclear-power.com
    The directional dose equivalent, H' (d, Ω), is the operational quantity for the determination of equivalent dose to the skin, lens of the eye, etc.
  40. [40]
    None
    ### Summary of Directional Dose Equivalent from the Document
  41. [41]
  42. [42]
    [PDF] RCO-2010-001, Personal Dose Equivalent Conversion Coefficients for
    Sep 27, 2010 · INTRODUCTION. The personal dose equivalent, Hp(d), is the quantity recommended by the International. Commission on Radiation Units and ...
  43. [43]
    ICRP
    ### Summary of Committed Effective Dose, Integration Over Time, Dose Rate for Internal Exposure, and Retention Functions from ICRP Publication 147
  44. [44]
  45. [45]
    [PDF] Calibration of radiation protection monitoring instruments
    The IAEA's safety standards are not legally binding on Member States but may be adopted by them, at their own discretion, for use in national regulations in ...
  46. [46]
    [PDF] Chapter 4 Radiation Monitoring Instruments
    ICRU sphere. ❑ The ICRU sphere, 30 cm in diameter, is a tissue- equivalent sphere. Composition: Oxygen. 76.2%. Carbon. 11.1%. Hydrogen. 10.1%. Nitrogen. 2.6%.
  47. [47]
    [PDF] ICRP Publication 103 The 2007 Recommendations of the ...
    ICRP Publication 103 provides recommendations for protection against ionizing radiation, updating previous recommendations and maintaining three fundamental ...
  48. [48]
    Committed effective dose - ICRPaedia
    The sum of the products of the sex-averaged committed organ- or tissue-equivalent doses, H_T(τ), and the appropriate tissue weighting factors (w_T).Missing: definition | Show results with:definition<|control11|><|separator|>
  49. [49]
  50. [50]
  51. [51]
  52. [52]
    ICRP
    ### Summary of ICRP Publication 66: Human Respiratory Tract Model (HRTM)
  53. [53]
  54. [54]
  55. [55]
  56. [56]
  57. [57]
    Dose Reconstruction Software (IMBA) | NIOSH - CDC
    IMBA is a licensed computer software program that is used by NIOSH to calculate individual organ doses which result from the intake of radioactive material ...Missing: committed | Show results with:committed
  58. [58]
    Internal Dose Calculation Software - imba
    IMBA (Integrated Modules for Bioassay Analysis) is a suite of software modules for internal dosimetry which implements the old recommendations.Missing: committed | Show results with:committed
  59. [59]
    Dept. of Radiation Measurement and Dose Assessment
    Nov 14, 2019 · QST (formerly, NIRS) developed a tool to facilitate internal dose calculations, MONDAL (MONitoring to Dose cALculation support system). We ...
  60. [60]
    Cancer Risk of Low Dose Ionizing Radiation - Frontiers
    Aug 11, 2020 · ... mSv. Obviously, high doses of ionizing radiation (>100 mSv) increases cancer risk [2], while at lower doses the situation is much less clear.
  61. [61]
    Epidemiological research on radiation-induced cancer in atomic ...
    The late effects of exposure to atomic bomb radiation on cancer occurrence have been evaluated by epidemiological studies on three cohorts.
  62. [62]
    A Historical Survey of Key Epidemiological Studies of Ionizing ...
    Jul 18, 2024 · We examine the findings from the epidemiological studies of the Japanese atomic bomb survivors, persons exposed to radiation for diagnostic or ...
  63. [63]
    None
    Nothing is retrieved...<|control11|><|separator|>
  64. [64]
    Effects of Exposure - ICRPaedia
    deterministic effects (harmful tissue reactions) due in large part to the killing/ malfunction of cells following high doses; and; stochastic effects, i.e., ...
  65. [65]
    None
    Below is a merged summary of deterministic radiation effects based on the provided segments, consolidating all information into a comprehensive response. To retain the maximum detail, I will use a combination of narrative text and tables in CSV format where applicable (e.g., for thresholds, mechanisms, and key data points). The response avoids any "thinking" tokens and focuses solely on presenting the synthesized information.
  66. [66]
    [PDF] Reevaluation of Radiation Protection Standards for Workers and the ...
    Jul 21, 2025 · For public exposures, the ICRP applies a substantially more-conservative standard, recommending a dose limit of 100 mrem per year—less than 1/ ...<|control11|><|separator|>
  67. [67]
    Human exposure to high natural background radiation: what can it ...
    The average annual effective dose from natural background radiation in the world is about 2.4 mSv [25] and, hence, about 160 mSv is accumulated over a 65-year ...
  68. [68]
    Assessment of radiation exposure in the uranium mining and milling ...
    The actual external exposure is around 1.2 mSv a(-1) at both locations and exposure from radon is around 3 mSv a(-1) at Mailuu Suu and around 10 mSv a(-1) at ...
  69. [69]
    What are the Radiation Risks from CT? - FDA
    Dec 5, 2017 · The effective doses from diagnostic CT procedures are typically estimated to be in the range of 1 to 10 mSv. This range is not much less than ...
  70. [70]
    White Paper: Initiative to Reduce Unnecessary Radiation Exposure ...
    Jun 14, 2019 · 0.005 mSv is the average adult effective dose from an intraoral dental x-ray. 0.01 mSv is the average adult effective dose from a panoramic ...<|control11|><|separator|>
  71. [71]
    The Chornobyl Accident - the UNSCEAR
    Average effective doses to those persons most affected by the accident were assessed to be about 120 mSv for 530,000 recovery operation workers, 30 mSv for ...Health Effects · Unscear Publications · Unscear 1988 Report, Annex D...Missing: Sv | Show results with:Sv
  72. [72]
    Radiation: Health consequences of the Fukushima nuclear accident
    Mar 10, 2016 · The average lifetime effective doses for adults in the Fukushima prefecture were estimated to be around 10 mSv or less, and about twice for 1-year old infants.
  73. [73]
    Background Radiation - Berkeley RadWatch
    The average exposure level across the United States is ~3mSv/yr, which corresponds to roughly 0.34 μSv/hr, and is more than twice the levels generally seen in ...
  74. [74]
    Overview of the Radiation Dosimetry Experiment (RaD-X) flight ... - NIH
    For the typical range of high-latitude GCR effective dose rates at commercial aviation altitudes [Lindborg et al., 2004; Mertens et al., 2013], ~5–10 μSv/h, a ...Missing: travel | Show results with:travel
  75. [75]
    Accurate assessment of patient effective radiation dose ... - PubMed
    A typical ablation procedure results in a total effective dose of 8.3 mSv per hour of fluoroscopy. The average excess of fatal cancers was estimated to be 650 ...
  76. [76]
    Radiation levels now | The Chernobyl Gallery
    22 years after the explosion radiation levels inside the reactor hall were approximately 34 Sv/hr – a lethal dose in 10-20 minutes. Shortly after the explosion ...
  77. [77]
    [PDF] Occupational Exposures at Nuclear Power Plants
    Apr 1, 2021 · there are 151 employees with annual individual doses exceeding 1 mSv; 4 with individual doses exceeding 5 mSv; none with individual doses ...
  78. [78]
    [PDF] Cosmic radiation exposure of aircrew and space crew
    6 mSv in a year is a typical radiation doses received by aircrew flying long-haul polar routes. For comparison: 3.0 mSv is an average radiation dose per year.
  79. [79]
    Frequently Asked Questions (FAQ) About Radiation Protection
    In fact, a person who spends a full year at the boundary of a nuclear power plant site would receive an additional radiation exposure of less than 1 percent of ...Missing: mSv/ | Show results with:mSv/
  80. [80]
    [PDF] PUBLIC EXPOSURE IN COMMERCIAL NATIONAL FLIGHTS TO ...
    The world average estimated by [4] for the effective dose due to cosmic radiation is 0.38 mSv per year, about 16% of the mean total dose. Within the ...
  81. [81]
    [PDF] The Fukushima Daiichi Accident
    the centralized monitoring of the health and radiation exposure of workers. Efforts to improve radiation protection of workers continued, and plans were put ...
  82. [82]
    Rolf Maximilian Sievert (1896–1966): father of radiation protection
    Jul 29, 2015 · In 1926, Sievert succeeded in standardizing the skin erythema dose and made a capacitor-type dosimeter, called a Sievert chamber. In 1928, he ...
  83. [83]
    Why Did They Call It That? The Origin of Selected Radiological and ...
    They did so in honor of former ICRP Chairman, Rolf Sievert, whose research focused on the biological effects of the low doses of radiation received by workers ...
  84. [84]
    The New Special Names of SI Units in the Field of Ionizing Radiations
    New SI units for ionizing radiations have been recommended by the International Commission on Radiation Units and Measurements (ICRU). ... Sievert (SI unit).
  85. [85]
  86. [86]
    Rolf Maximilian Sievert, the father of radiation protection
    Jul 5, 2018 · By 1926, Sievert succeeded in standardizing the skin erythema dose and made a capacitor-type dosimeter, called a Sievert chamber. In 1928, he ...
  87. [87]
    Rem - Nuclear Regulatory Commission
    The related international system unit is the sievert (Sv), where 100 rem is equivalent to 1 Sv. For additional information, see Doses in Our Daily Lives and ...<|control11|><|separator|>
  88. [88]
  89. [89]
  90. [90]
  91. [91]
  92. [92]
  93. [93]
    [PDF] The International Commission on Radiological Protection
    Recommendations in the 1950s​​ In 1954, the ICRP introduced the rem (roentgen equivalent man) as a unit of absorbed dose weighted for the way different types of ...Missing: origin NIST
  94. [94]
    [PDF] The International System of Units (SI)
    In the field of ionizing radiation, the SI unit of activity is designated the becquerel rather than the reciprocal second, and the SI units of absorbed dose.
  95. [95]
    PART 20—STANDARDS FOR PROTECTION AGAINST RADIATION
    Public dose means the dose received by a member of the public from exposure to radiation or to radioactive material released by a licensee, or to any other ...
  96. [96]
    [PDF] Radiation Protection Policy in a Nuclear Era
    Transitioning to SI units exclusively would align U.S. practices with ICRP and IAEA recommendations, reduce conversion-related errors, and simplify training ...Missing: sievert BIPM
  97. [97]
    Resolution 5 of the 16th CGPM (1979) - BIPM
    adopts the special name sievert, symbol Sv, for the SI unit of dose equivalent in the field of radioprotection. The sievert is equal to the joule per kilogram.
  98. [98]
    Derived units - BIPM
    CIPM Recommendation 1 (1984). Concerning the sievert. DOI : 10.59161/CIPM1984REC1E. CIPM Recommendation 2 (2002). Dose equivalent. DOI : 10.59161/CIPM2002REC2E.
  99. [99]
    [PDF] Guide for the Use of the International System of Units (SI)
    Feb 3, 1975 · Example: N · m or N m. Notes: 1. A half-high dot or space is usually imperative. For example, m · s−1 is the symbol for the meter per second ...Missing: pitfalls | Show results with:pitfalls
  100. [100]
    Ansers to frequently asked questions about radiation - the UNSCEAR
    Annual dose to nuclear worker. 1. Annual cosmic radiation at sea level. 0.4. Annual cosmic radiation Mexico City (2 300m). 0.8. Chernobyl recovery workers in ...What Is Radiation? · What Levels Of Radiation... · What Are The Effects Of...
  101. [101]
    SI Brochure - BIPM
    SI Brochure: The International System of Units (SI). Note for translators and editors: Details on changes made since May 2019 are available on request to ...Missing: sievert | Show results with:sievert
  102. [102]
    Roentgen (R) - Nuclear Regulatory Commission
    A unit of exposure to ionizing radiation. It is the amount of gamma or x-rays required to produce ions resulting in a charge of 0.000258 coulombs/kilogram ...