CT scan

A computed tomography (CT) scan, also known as a CAT scan, is a noninvasive technique that utilizes X-rays and advanced computer algorithms to generate detailed cross-sectional images, or "slices," of the body's internal structures, allowing for three-dimensional reconstruction when multiple slices are combined. Developed independently in the early 1970s by British engineer and South African physicist Allan Cormack—who shared the 1979 in Physiology or Medicine for their work—the first clinical CT scan was performed in 1971 on a patient's brain at Atkinson Morley's Hospital in . CT imaging works by directing a narrow beam of X-rays through the body from multiple angles as the scanner rotates around the patient; detectors on the opposite side measure the radiation attenuation caused by different tissues, and the computer processes this data using mathematical algorithms, such as filtered back projection, to produce high-resolution images that differentiate between , , blood vessels, and organs. This technology revolutionized diagnostic radiology by providing superior contrast and detail compared to conventional X-rays, enabling the detection of abnormalities like tumors, fractures, , and infections that might be invisible on standard radiographs. Common applications include evaluating head trauma, guiding biopsies, planning surgeries, monitoring cancer treatment, and assessing cardiovascular conditions, with modern advancements like multi-slice spiral CT allowing faster scans and reduced motion artifacts. While CT scans are invaluable for their speed and accuracy—typically taking just minutes—they involve exposure, equivalent to 100–500 chest X-rays depending on the protocol, necessitating judicious use to minimize risks such as potential long-term cancer induction, particularly in children.

Fundamentals

Basic principles

Computed tomography (CT) is a radiographic imaging modality that utilizes X-ray beams rotated around the body to acquire multiple projections, which are computationally reconstructed to produce cross-sectional tomographic images of internal anatomy. This technique enables visualization of tissue densities in thin slices, distinguishing it from conventional radiography by eliminating superimposition of structures. Tomography, the core concept in CT, involves imaging discrete planes or "slices" of the body, typically 1-10 mm thick, to isolate structures without overlap from adjacent tissues. Digital imaging forms the basis for CT output, representing each slice as a two-dimensional matrix of pixels (or voxels in ), where pixel values encode tissue characteristics derived from data. The primary physical principle of CT is attenuation, whereby tissues absorb or scatter incident X-rays based on their , effective , and the (typically 20-150 keV). As the beam traverses the body, its intensity decreases exponentially according to the linear (μ), which quantifies the probability of interaction per unit ; denser tissues like exhibit higher μ values, attenuating more than soft tissues or air. Attenuation measurements are standardized using Hounsfield units (HU), a that assigns numerical values to relative radiodensities for consistent tissue characterization across scanners. is defined as 0 HU, air as -1000 HU, and other materials scaled accordingly via the formula: \text{HU} = 1000 \times \frac{\mu_{\text{tissue}} - \mu_{\text{water}}}{\mu_{\text{water}} - \mu_{\text{air}}} where μ represents the ; for example, approximates -100 to +100 HU, while cortical reaches +1000 HU or higher. In operation, a rotating emits a fan- or cone-shaped beam that penetrates the body from numerous angles (often 360° or more per slice), while an opposing array of detectors captures the transmitted intensity to form profiles. These detectors, commonly solid-state scintillators coupled to photodiodes, convert photons into proportional electrical signals, which are digitized by the system for further processing. Reconstruction of 2D slices from these s relies on algorithms like filtered back- (FBP), a widely adopted method that mathematically inverts the projection data. FBP back-projects attenuated sums onto a grid and applies convolution filters (e.g., Ram-Lak or Shepp-Logan) to sharpen edges and mitigate blurring from simple summation, yielding quantitative images with pixel values in . This approach, efficient for clinical use, stems from the and has been foundational since early CT systems.

Image generation

In computed (CT), the generation of images from involves acquiring projections in specific followed by computational . typically employs fan-beam or cone-beam configurations. In fan-beam , a collimated, fan-shaped beam passes through the patient and is detected by a one-dimensional linear detector array, yielding projections that represent line integrals of tissue along each path. Cone-beam extends this to a diverging, cone-shaped beam incident on a two-dimensional area detector, enabling simultaneous capture of a volumetric in a single . Projections are systematically collected over a full 360-degree of the source and detectors around the patient to provide comprehensive angular sampling for accurate . These projections form a dataset, which encodes the of the object's attenuation function. Reconstruction algorithms then invert this transform to produce cross-sectional images depicting the spatial distribution of attenuation coefficients. The predominant analytical technique is filtered back-projection (FBP), which applies a ramp to the projections in the before back-projecting them across all angles. The , central to this process, is mathematically defined as p(\theta, s) = \int_{-\infty}^{\infty} \int_{-\infty}^{\infty} f(x, y) \, \delta(x \cos\theta + y \sin\theta - s) \, dx \, dy, where f(x, y) represents the two-dimensional attenuation function, \theta denotes the projection angle, s is the perpendicular distance from the rotation center to the ray, and \delta is the Dirac delta function. FBP reconstructs f(x, y) via f(x, y) = \int_0^\pi \int_{-\infty}^{\infty} |\nu| \, P(\nu, \theta) \, e^{i 2\pi \nu (x \cos\theta + y \sin\theta)} \, d\nu \, d\theta, with P(\nu, \theta) as the Fourier transform of p(\theta, s); this method is computationally efficient and widely implemented in clinical scanners for its speed in generating high-quality images from complete datasets. For scenarios with incomplete projections, noise, or the need to incorporate prior knowledge, iterative methods such as the algebraic reconstruction technique (ART) offer superior performance. ART models the imaging process as a large system of linear equations, \sum_j w_{ij} f_j = p_i for each projection i and pixel j, where w_{ij} are weights based on ray-path intersections with the image grid (often binary: 1 if the ray passes through pixel j, 0 otherwise). It solves this underdetermined system iteratively using the Kaczmarz method, updating pixel values as f_j^{(k)} = f_j^{(k-1)} + \frac{p_i - q_i^{(k-1)}}{N_i} w_{ij}, where q_i^{(k-1)} = \sum_j w_{ij} f_j^{(k-1)} is the estimated projection, and N_i is the number of pixels intersected by ray i. This sequential projection onto hyperplanes converges to a solution that minimizes inconsistencies, reducing artifacts in limited-angle or low-dose acquisitions while enforcing constraints like non-negativity. Reconstructed images are axial slices whose thickness is primarily determined by the detector collimation width during , which dictates the minimum resolvable dimension along the patient's longitudinal () and thus the voxel depth. Collimation settings typically yield slices from 0.5 mm to 5 mm thick, balancing against noise—thinner slices enhance detail for fine structures but amplify , while thicker ones average signal for smoother images. To create a three-dimensional , contiguous or overlapping slices are stacked and interpolated into a grid, where each isotropic or anisotropic encapsulates data in a cubic or rectangular prism defined by in-plane spacing (e.g., 0.5–1 mm) and z-thickness; this volumetric dataset enables multiplanar reformatting and surface rendering for comprehensive visualization. Studies confirm that slice thicknesses ≤3 mm optimize accuracy in tasks, with deviations increasing markedly beyond 5 mm (e.g., root-mean-square error rising from ~0.92 mm at 3 mm to 1.38 mm at 5 mm). The final output consists of digital images stored in the standard, ensuring across medical systems. The CT Image Information Object Definition (IOD) defines the structure for basic axial slices, incorporating arrays alongside such as demographics, parameters (e.g., kVp, , slice thickness), and quantitative values in Hounsfield units. For volumetric or multi-frame datasets from modern multi-detector CT, the Enhanced CT Image IOD extends this with attributes like (value: "CT"), Frame of Reference for spatial alignment, and sequences referencing performed procedures; it supports multi-frame encoding to represent volumes efficiently while preserving details.

Procedure

Patient preparation

Patient preparation for a CT scan involves several steps to ensure , optimize image quality, and minimize risks, particularly when agents are used. Healthcare providers conduct a thorough pre-scan to identify potential contraindications and tailor the procedure accordingly. Pre-scan screening begins with a detailed , including any known allergies to media, as reactions can range from mild to severe. Patients with a history of allergic reactions may receive such as corticosteroids or antihistamines to mitigate risks. function is assessed via serum or estimated (eGFR) testing, especially for -enhanced scans; according to the American College of (ACR) and National Foundation (NKF) consensus, intravenous is generally safe for patients with eGFR >30 mL/min/1.73 m², but alternatives like non- CT or MRI are considered for those with eGFR <30 mL/min/1.73 m² to avoid -induced nephropathy. Pregnancy status must be confirmed in all women of childbearing potential, as ionizing radiation poses a small but potential risk to the fetus; head or chest CTs carry minimal fetal exposure, while abdominal or pelvic scans are avoided if possible, with ultrasound or MRI preferred as alternatives. According to ACR guidelines, fasting is not routinely required prior to IV contrast administration. However, some protocols or institutions may advise avoiding solid food for a few hours; patients should follow their healthcare provider's specific instructions. For scans requiring oral contrast (e.g., abdominal CT), patients may be instructed to drink a contrast solution over 30-60 minutes before the scan to visualize the gastrointestinal tract. Hydration is encouraged before and after the procedure, particularly for those with compromised kidney function, to facilitate contrast excretion and lower the incidence of adverse renal effects. Informed consent is obtained after the healthcare team explains the procedure's benefits, potential risks—such as radiation exposure equivalent to 100-200 chest X-rays for a typical abdominal —and rare complications like contrast reactions. Patients are informed that while the lifetime cancer risk from a single CT scan is low (approximately 1 in 2,000), cumulative exposure should be minimized. To prepare for positioning, patients remove all metal objects (e.g., jewelry, eyeglasses, dentures) and clothing, donning a hospital gown to prevent imaging artifacts. During the scan, immobilization aids such as straps, pillows, or head cradles are used to maintain stillness and reduce motion blur; patients may also be asked to hold their breath briefly for certain acquisitions.

Scanning process

The scanning process begins with the patient being positioned on a motorized table that slides into the gantry of the CT scanner. The technologist typically places the patient supine (lying flat on their back), though prone or lateral positions may be used depending on the anatomical region of interest. Straps and pillows are often employed to immobilize the patient and maintain alignment. Laser markers, projecting red lines onto the patient's skin, assist in precise alignment to ensure the scan covers the intended area accurately. Once positioned, the technologist selects scan parameters tailored to the clinical indication, patient size, and desired image quality. Key parameters include tube voltage (kVp), typically ranging from 80 to 140 kVp to balance penetration and contrast; tube current-time product (mAs), which controls radiation dose and noise; and pitch, defined as the table movement per gantry rotation relative to the collimated beam width, often set between 0.5 and 1.5 for optimal coverage and dose efficiency. These settings are adjusted via the scanner's console to minimize artifacts and radiation exposure while achieving diagnostic resolution. The gantry, housing the X-ray tube and detector array, then rotates continuously around the patient at speeds of 0.3 to 1 second per full 360-degree rotation. Modern multi-slice detectors, with up to 320 rows, capture data from multiple slices simultaneously, enabling rapid volumetric acquisition over large areas such as the chest or abdomen. As the table advances incrementally or continuously (depending on the scan mode), the X-ray beam fans across the patient, and detectors measure transmitted radiation to generate projection data. Throughout the scan, a radiologic technologist monitors the patient from an adjacent control room via audio and visual systems, providing instructions such as breath-holding to reduce motion artifacts—typically for 5 to 20 seconds per phase. The technologist can pause or adjust the scan if needed. Total scan duration varies from a few seconds for limited head scans to several minutes for multi-phase abdominal studies, after which the raw data undergoes image reconstruction to produce cross-sectional images.

Types

Conventional scanning

Conventional scanning, also known as sequential or step-and-shoot acquisition, was the foundational method in computed tomography (CT) imaging, originating with the first-generation scanners developed in the early 1970s. This translate-rotate system, pioneered by , utilized a narrow pencil beam from a single X-ray source directed at one or two detectors, with the source-detector pair translating linearly across the patient to capture parallel projections before the gantry rotated by small increments (typically 1-2 degrees). To acquire a full dataset for one slice, approximately 180 such translate-rotate cycles were performed over 180 degrees, after which the patient table advanced to the next position. The entire process for a head scan typically required 5-10 minutes due to the sequential nature and mechanical constraints. In operation, the table halts precisely for each slice, the gantry performs multiple translate-rotate cycles, with linear translation for each small angular increment (typically 1°), over a total of approximately 180° to acquire the projection data for one slice. This discrete acquisition per slice provided high image quality in regions with minimal motion, such as the brain, where it excelled in early diagnostic applications by enabling clear visualization of intracranial abnormalities without the blurring from patient movement between slices. However, the prolonged scan times increased the risk of voluntary motion artifacts, and in three-dimensional reconstructions, the non-overlapping slices often produced stair-step artifacts along inclined surfaces, degrading volumetric accuracy. Today, conventional scanning persists in niche applications where its precision is advantageous, such as CT-guided biopsy procedures that require targeted, intermittent imaging to monitor needle placement without continuous exposure. It is also employed when helical scanning is contraindicated, for instance, in scenarios demanding exact slice positioning or reduced radiation from overranging, like certain high-resolution head examinations.

Helical scanning

Helical scanning, also known as spiral CT, involves the continuous rotation of the X-ray tube around the patient while the examination table moves at a constant speed through the gantry, resulting in a helical or spiral path of data acquisition. This technique allows for uninterrupted volumetric imaging without the need for pauses between slices, enabling the acquisition of a continuous dataset over a large volume. A key parameter in helical scanning is the pitch factor, defined as the ratio of the table feed distance per gantry rotation to the total collimated beam width. For single-slice helical CT, pitch is calculated as table movement per 360° rotation divided by the beam collimation; in multi-slice systems, it is the table movement divided by the total thickness of all simultaneously acquired slices. A pitch of 1.0 results in contiguous x-ray beams with no overlap or gaps, while values greater than 1.0 introduce gaps that reduce radiation dose but may lower image quality due to fewer projections, and values less than 1.0 cause overlap for improved signal-to-noise ratio at the cost of higher dose; typical clinical pitches range from 1.0 to 1.5 to balance speed, coverage, and quality. Image reconstruction in helical scanning relies on interpolation algorithms to generate transverse slices from the helical dataset at arbitrary z-axis positions. Common methods include 360° linear interpolation (360LI) and 180° linear interpolation (180LI), which estimate data for specific slice planes by interpolating between measured projections; advanced variants, such as z-filtering interpolation, use multiple data points to minimize artifacts and improve slice sensitivity profiles, particularly in multi-slice systems where cone-beam effects and discontinuous sampling occur. These algorithms enable retrospective reconstruction of images at any interval, facilitating multiplanar reformations and three-dimensional visualizations without additional scanning. The primary benefits of helical scanning include dramatically reduced scan times—often under 30 seconds for chest imaging—compared to conventional methods, minimizing patient motion artifacts and allowing breath-hold acquisitions for better organ enhancement. It produces isotropic volumetric datasets that support high-quality multiplanar and three-dimensional reformats, improving visualization of vascular structures and small lesions. Helical scanning evolved from single-slice systems introduced in 1989, which used slip-ring technology for continuous rotations as short as 1 second, enabling initial applications like CT angiography. This progressed to multi-detector row CT (MDCT) around 1999, starting with four detector rows and expanding to 16 or more, which increased z-axis coverage per rotation (up to 4–16 cm) and scan speeds while maintaining thin-slice resolution for whole-body imaging in a single breath-hold. MDCT further reduced motion artifacts in dynamic studies, such as cardiac imaging, by acquiring multiple slices simultaneously during helical acquisition.

Advanced modalities

Advanced CT modalities extend the capabilities of standard helical scanning by incorporating specialized technologies for improved temporal resolution, material differentiation, quantitative perfusion assessment, spectral imaging, and multimodal integration. These variants address limitations in motion artifact reduction, tissue characterization, and functional evaluation, enabling more precise diagnostics in complex scenarios such as cardiac motion or multi-material analysis. Electron beam computed tomography (EBCT), also known as ultrafast CT, is designed for high-speed cardiac imaging without mechanical rotation of the X-ray source. It employs an electron beam deflected across stationary tungsten targets to generate X-rays, allowing image acquisition in as little as 50-100 milliseconds per slice, which minimizes motion artifacts from heartbeats. This ultrafast scanning, typically achieving full heart coverage in under 100 ms, has been particularly valuable for coronary calcium scoring and assessing myocardial perfusion in patients with arrhythmias. Dual-energy CT (DECT) utilizes two distinct X-ray energy spectra, commonly generated by switching between 80 kVp and 140 kVp tube voltages, to differentiate materials based on their energy-dependent attenuation properties. This enables post-processing techniques for material decomposition, such as separating iodine from soft tissue or quantifying uric acid deposits, with applications in detecting gout through visualization of monosodium urate crystals in joints. DECT also facilitates virtual non-contrast imaging and iodine mapping for enhanced lesion conspicuity, reducing the need for additional scans and contrast agents. CT perfusion imaging involves dynamic, repeated scanning following intravenous contrast administration to quantify blood flow parameters in tissues, particularly in the brain for stroke evaluation. Key metrics include cerebral blood volume (CBV), calculated as the ratio of the area under the tissue time-enhancement curve to that of the arterial input function, which reflects the volume of blood in a given tissue region. This technique provides maps of cerebral blood flow, mean transit time, and permeability, aiding in the identification of ischemic penumbra and guiding thrombolytic therapy decisions. Photon-counting CT (PCCT), an emerging technology as of 2025, uses direct-conversion detectors that count individual X-ray photons and resolve their energies, enabling spectral imaging without the need for dual-source hardware. This approach improves spatial resolution, reduces electronic noise, and allows multi-energy material decomposition, while achieving dose reductions of 30-50% compared to conventional CT through better photon utilization efficiency. The U.S. Food and Drug Administration approved the first commercial PCCT system, the Siemens NAEOTOM Alpha, in 2021, with subsequent clearances for enhanced models through 2025, including the Siemens Naeotom family (March 2025), GE HealthCare systems (June 2025), and NeuroLogica OmniTom Elite (January 2025), advancing its clinical use for oncology and cardiology. Hybrid PET-CT combines positron emission tomography (PET) with CT in a single gantry for simultaneous acquisition of functional metabolic data from PET and high-resolution anatomical images from CT. This integration provides precise spatial correlation between hypermetabolic lesions and their structural context, enhancing staging accuracy in oncology and detection of viable myocardium in cardiac disease. The modality's attenuation correction using CT further improves PET quantification, making it indispensable for whole-body tumor assessment.

Clinical applications

Head and neck imaging

Computed tomography (CT) plays a pivotal role in head and neck imaging, providing rapid, high-resolution visualization of bony structures, soft tissues, and vascular components to aid in the diagnosis and management of various pathologies in the cranial and cervical regions. In trauma assessment, non-contrast CT serves as the initial imaging modality of choice for detecting acute intracranial hemorrhages, such as epidural and subdural hematomas, as well as skull fractures and parenchymal injuries. This approach excels in identifying hyperdense extra-axial collections, mass effect from edema, and associated midline shifts, enabling timely intervention in moderate to severe traumatic brain injury cases. Non-contrast protocols are preferred due to their sensitivity for acute blood products and ability to exclude contraindications for subsequent contrast-enhanced studies if needed. For stroke evaluation, non-contrast CT is essential for identifying early signs of acute ischemia, including the hyperdense middle cerebral artery (MCA) sign, which indicates thrombus within the vessel and correlates with arterial occlusion. This sign appears as increased attenuation in the on axial slices and helps differentiate ischemic from hemorrhagic stroke. Perfusion CT further enhances assessment by mapping the ischemic penumbra—the salvageable tissue surrounding the infarct core—through parametric maps of cerebral blood flow, volume, and mean transit time, guiding thrombolytic or endovascular therapies. In sinus and ear, nose, and throat (ENT) imaging, CT delineates mucosal thickening, a hallmark of inflammatory conditions like sinusitis, often involving the maxillary and ethmoid sinuses even in asymptomatic cases. For neoplastic processes, such as sinonasal tumors, contrast-enhanced CT evaluates lesion extent, bony erosion, and vascularity, with enhancement patterns varying by histology—for instance, squamous cell carcinomas typically show moderate to avid uptake, aiding in preoperative planning. These scans also assess complications like orbital or intracranial extension in aggressive ENT pathologies. Neck imaging with CT is crucial for oncologic staging, particularly in evaluating cervical lymph node involvement through size, shape, and enhancement criteria to determine metastatic spread. In thyroid cancer, contrast-enhanced CT identifies suspicious nodules by features like local invasion or calcifications and assesses regional nodes for cystic changes or necrosis indicative of malignancy, supporting surgical and therapeutic decisions. This modality complements ultrasound for comprehensive nodal mapping, though it may overestimate inflammation-related enlargement.

Thoracic and abdominal imaging

Computed tomography (CT) plays a central role in evaluating thoracic and abdominal structures, providing detailed cross-sectional images that aid in diagnosing a wide range of conditions affecting the lungs, pleura, mediastinum, and abdominal viscera. In thoracic imaging, CT excels at assessing pulmonary vasculature and parenchymal abnormalities, while abdominal protocols focus on gastrointestinal, hepatobiliary, and retroperitoneal pathologies. Contrast-enhanced techniques are often employed to enhance lesion conspicuity, with timing of image acquisition optimized for specific diagnostic needs. For pulmonary conditions, CT pulmonary angiography (CTPA) serves as the gold standard for detecting pulmonary embolism (PE), utilizing intravenous iodinated contrast to opacify the pulmonary arteries and reveal filling defects indicative of thrombi. CTPA demonstrates high sensitivity and specificity, with diagnostic criteria including direct visualization of emboli as intraluminal defects, often corroborated by ancillary signs such as right ventricular strain or peripheral wedge-shaped infarcts. In lung cancer screening, low-dose CT protocols are recommended for high-risk individuals to detect pulmonary nodules, which appear as well-defined, round opacities typically measured in millimeters to assess malignancy risk using size, density, and growth patterns over serial scans. These protocols prioritize nodule identification while minimizing radiation exposure, with guidelines emphasizing follow-up for nodules exceeding 6 mm in diameter. In abdominal imaging, CT is highly effective for diagnosing acute appendicitis, where key findings include an enlarged appendix greater than 6 mm in outer diameter, periappendiceal fat stranding, and wall thickening; the hyperdense appendix sign on unenhanced CT, reflecting intraluminal hemorrhage or debris, is observed in approximately 33% of cases and carries a low false-positive rate. For liver lesions, multiphase contrast-enhanced CT protocols—acquiring images in non-contrast, arterial, portal venous, and delayed phases—characterize focal abnormalities such as hemangiomas, cysts, or malignancies by their enhancement patterns; for instance, hepatocellular carcinomas often show arterial phase hyperenhancement followed by washout. These phases exploit the dual blood supply of the liver, with arterial phase highlighting hypervascular lesions and portal venous phase optimizing hypovascular ones. In oncology, CT is indispensable for staging thoracic and abdominal tumors, measuring primary lesion size to determine T-stage and evaluating for metastasis, particularly in the liver and lymph nodes during the portal venous phase, where hypovascular metastases appear as low-attenuation defects against enhanced parenchyma. This phase maximizes detection of colorectal and other gastrointestinal metastases, influencing treatment decisions such as surgical resectability or systemic therapy. Quantitative assessment of tumor dimensions and metastatic burden via response evaluation criteria in solid tumors (RECIST) relies on these images for monitoring progression. Dose-optimized protocols balance diagnostic accuracy with radiation safety; low-dose CT for lung screening delivers 1-3 mSv effective dose, comparable to several chest radiographs, while standard diagnostic thoracic CT ranges from 5-10 mSv, and multiphase abdominal scans 10-20 mSv, reflecting the need for higher resolution in complex evaluations. Iterative reconstruction algorithms further reduce doses without compromising image quality. Motion artifacts from breathing may occasionally degrade thoracic images but are mitigated through breath-hold techniques.

Vascular and cardiac imaging

Computed tomography (CT) plays a crucial role in vascular and cardiac imaging by providing detailed visualization of blood vessels and heart structures, enabling the diagnosis of conditions such as stenoses, dissections, and ischemic damage. CT angiography (CTA) is a primary technique for assessing arterial pathologies, while specialized protocols address cardiac motion and perfusion to enhance diagnostic accuracy. These applications leverage contrast enhancement and gating to differentiate vascular abnormalities from cardiac dysfunction. In CT angiography, precise bolus timing is essential for optimal arterial opacification, achieved through techniques like bolus tracking or test bolus injections to synchronize contrast arrival with scan initiation. This ensures uniform enhancement of vessels, allowing for accurate quantification of stenoses, such as in coronary arteries where the measures calcification by multiplying lesion area by a density factor based on (e.g., 130 HU threshold for calcium detection). The categorizes risk, with values over 400 indicating significant coronary artery disease burden. Dual-energy CT can briefly reference plaque composition, but its primary utility lies in material differentiation beyond standard CTA. Cardiac gating minimizes motion artifacts in CT imaging of the heart, with prospective ECG-triggered scans acquiring data only during specific diastolic phases to reduce blurring and radiation exposure by up to 77% compared to retrospective methods. This approach is particularly effective for coronary CTA, where heart rate control further limits artifacts. Functional assessment, including left ventricular ejection fraction, is derived from gated datasets by measuring end-diastolic and end-systolic volumes, yielding values around 60% for the left ventricle in healthy individuals and showing good correlation with MRI benchmarks. For acute chest pain evaluation, triple-rule-out protocols integrate CTA to simultaneously assess coronary stenosis, aortic dissection, and pulmonary embolism in a single scan, using ECG gating and timed contrast to cover the thorax efficiently. In aortic dissection, this protocol identifies intimal flaps and false lumens with high sensitivity, guiding urgent interventions. CT perfusion imaging integrates with angiography to evaluate myocardial viability in ischemic conditions, quantifying blood flow defects during stress to distinguish reversible ischemia from infarction. Dynamic perfusion scans measure myocardial blood flow, improving specificity for obstructive disease when combined with CTA, and help assess reperfusion injury in acute settings.

Musculoskeletal imaging

Computed tomography (CT) plays a pivotal role in musculoskeletal imaging by providing high-resolution visualization of bones, joints, and soft tissues, particularly for evaluating trauma, degenerative conditions, and preoperative planning. Its ability to generate detailed cross-sectional images allows for accurate assessment of skeletal structures, often surpassing plain radiography in detecting subtle abnormalities. Advanced techniques such as multi-slice CT and dual-energy CT (DECT) enhance diagnostic precision in this domain. In fracture detection, CT excels at identifying complex and nondisplaced injuries, including those not visible on initial radiographs. Three-dimensional (3D) reconstructions from CT data facilitate comprehensive evaluation of fracture patterns, such as burst fractures in the spine, where retropulsed fragments into the spinal canal are pathognomonic of axial compression injuries. For instance, CT analysis reveals the size, location, and characteristics of these fragments, aiding in surgical decision-making. High-resolution CT (HRCT) further improves depiction of cortical bone disruptions in extremities. For joint assessment, CT is valuable in evaluating arthritis and intra-articular pathology. DECT enables detection of structural changes and active inflammation in conditions like gouty arthritis by differentiating urate deposits from other tissues. HRCT provides detailed imaging of cortical bone erosion and joint space narrowing in osteoarthritis. Additionally, CT effectively identifies loose bodies within joints, such as calcified fragments in the knee or hip, which can cause mechanical symptoms; arthrography enhances sensitivity for non-calcified bodies. Orthopedic planning benefits significantly from CT, particularly for implant sizing and tumor resection. Preoperative multi-detector CT (MDCT) measurements of femoral dimensions in total knee arthroplasty correlate highly with intraoperative findings, achieving almost perfect agreement (kappa > 0.80) for key parameters like transepicondylar width and condylar dimensions, thus optimizing component selection. In musculoskeletal tumors, CT delineates extent and involvement, guiding resection margins to ensure complete removal while preserving function. Biomechanical analysis leverages CT-derived models for simulating bone stress and predicting failure. Finite element modeling (FEM) uses patient-specific CT scans to segment bone geometry and assign material properties via quantitative CT, enabling accurate stress simulations; for example, such models correlate strongly (r² > 0.9) with experimental data for hip fracture risk under loading. This approach supports implant design and personalized orthopedics by quantifying strain distributions in complex structures like the tibiofemoral joint. Multiplanar reformats from CT data further aid in visualizing these simulations.

Non-medical applications

Industrial inspection

Industrial computed tomography (CT) scanning serves as a critical non-destructive testing (NDT) method in , enabling the visualization and analysis of internal structures within components without physical alteration. This technique employs projections to reconstruct three-dimensional images, facilitating the identification of defects that could compromise product integrity during processes. In non-destructive testing, CT scanning excels at detecting voids and inclusions in castings, where internal porosity or material discontinuities are common issues that affect mechanical performance. For instance, porosity analysis via CT reveals the size, distribution, and location of voids in metal castings, allowing manufacturers to assess compliance with standards without sectioning the part. Weld integrity evaluation benefits particularly from micro-CT variants, which provide high-resolution imaging to uncover cracks, lack of fusion, or incomplete penetration in welds, ensuring structural reliability in assembled components. Metrology applications leverage industrial CT for precise dimensional accuracy measurements, achieving sub-micron to verify internal and external geometries against design specifications. This capability supports part-to-CAD comparisons and wall thickness assessments, with systems capable of detecting features as small as 0.5 micrometers, far surpassing traditional contact-based methods in complex or inaccessible regions. In additive manufacturing, CT scanning is essential for internal defect analysis in 3D-printed parts, identifying issues such as unmerged layers, , or residual stresses that arise during layer-by-layer fabrication. By generating volumetric data, it enables quantitative evaluation of defect volumes and densities, aiding optimization and of parts produced via techniques like or fused deposition modeling. Representative examples include automotive parts inspection, where CT verifies the integrity of engine components like cylinder heads for casting voids and weld flaws, reducing failure risks in high-stress environments. In electronics assembly verification, CT confirms solder joint quality and component alignment in circuit boards, detecting hidden voids or misplacements that could lead to reliability issues.

Security screening

In and border security, computed (CT) scanners are widely deployed for baggage and cargo screening to identify prohibited objects, leveraging multi-energy imaging to differentiate materials based on and density. These systems distinguish organic materials, such as explosives or narcotics, from inorganic ones like metals, enabling precise threat assessment without manual unpacking. For instance, dual-energy CT generates volumetric images that allow operators to rotate and inspect virtual representations of contents, improving detection accuracy over traditional 2D methods. Explosive detection in these scanners relies on advanced algorithms that analyze data for signatures of known threats, including explosives and densely shielded items, often achieving high sensitivity with low rates. Certified systems, such as the Rapiscan 920CT, use automated software to flag potential hazards in , complying with standards for and facilitating faster throughput at checkpoints. Multi-energy enhances this by segmenting materials into categories like low-Z () and high-Z (metallic), reducing operator subjectivity and supporting regulatory requirements for systems. Integration of () into CT security screening automates threat recognition by training models on vast datasets of scanned images, identifying prohibited items with greater speed and precision than human operators alone. AI algorithms, like those in SeeTrue for CT, perform 3D object segmentation to detect occluded or irregularly shaped threats, reducing false positives by up to 20% and minimizing unnecessary secondary inspections. Partnerships, such as between Analogic and Analytical AI, enhance CT-based detection software for and , enabling alerts that boost overall checkpoint . The U.S. (TSA) incorporates AI for image analysis in its screening protocols, focusing on prohibited items to streamline passenger flow.

Scientific research applications

Computed tomography (CT) scanning has become an indispensable tool in geological research, enabling non-destructive of core samples to map and examine internal structures. High-resolution micro-CT images of core samples provide detailed data on distribution, , and structural features, such as networks and fractures, which are critical for understanding fluid flow and reservoir characteristics in subsurface formations. For instance, CT scans of saturated core samples allow researchers to quantify by differentiating between air- and water-filled voids, offering insights into petrophysical properties without invasive methods. In fault , CT precisely delineates the location, size, and shape of faults and mineral grains within rocks, facilitating the study of deformation mechanisms and tectonic histories. In , CT scanning permits the examination of internal structures without physical damage, revolutionizing the study of ancient organisms. Micro-CT techniques reveal hidden anatomical details, such as vascular networks in , by generating three-dimensional reconstructions of endocasts and impressions encased in rock. This non-destructive approach allows paleontologists to assess , growth patterns, and pathologies, as seen in analyses of tyrannosaurid where CT uncovered orientations indicative of physiological traits. Synchrotron-enhanced CT further enhances , enabling the visualization of microscopic features like neural canals in early , preserving specimens for future study. CT applications extend to cultural heritage preservation, where scanning supports artifact restoration by providing detailed internal views for planning interventions. For mummified remains, such as ancient Egyptian specimens, CT scans document wrappings, skeletal integrity, and materials without unwrapping, aiding in strategies and virtual reconstructions. In the case of Ramesses II's , modified CT protocols revealed desiccated tissue layers and artifacts, informing restoration efforts while minimizing handling risks. Similarly, CT of animal mummies, like a specimen, identifies bone positions and wrappings, contributing to non-invasive and display preparation. These scans also enable of replicas for public exhibition, reducing wear on originals. In biological research, micro-CT facilitates the three-dimensional morphological analysis of cellular and tissue structures, particularly in non-mineralized samples. Simple staining methods enhance contrast, allowing high-resolution imaging of soft tissues like organs or embryos, which supports studies. For cellular-level investigations, micro-CT characterizes constructs in cell cultures, quantifying and scaffold interactions in models. In forestry applications, micro-CT detects internal defects in timber, such as knots and cracks, by scanning logs to assess and optimize use without sectioning. This technique measures density variations and moisture content , aiding sustainable harvesting decisions. Advancements in synchrotron CT have elevated scientific research by achieving ultra-high resolutions, often down to sub-micron scales, for complex samples. Synchrotron sources produce coherent X-rays that enable rapid, artifact-free reconstructions of biological and geological specimens, such as cellular ultrastructures in tissues or nanoscale in rocks. With resolutions as fine as 20 nm per , these systems support studies of dynamic processes, like deformation in materials under load, far surpassing conventional lab-based . integration further refines image quality from low-dose scans, expanding applications in time-sensitive experiments.

Image interpretation

Display and reconstruction techniques

CT images are typically displayed in grayscale, where Hounsfield units (HU) are mapped to a limited range of 256 gray levels to accommodate human visual perception, as the full HU scale spans over 4000 units from -1000 (air) to over +3000 (metals), with dense bone typically +1000 to +2000 HU. This mapping is adjusted through windowing techniques, which optimize contrast and brightness for specific tissues without altering the raw data. Window width defines the range of HU values displayed, with narrower widths enhancing contrast between similar densities (e.g., soft tissues) and wider widths accommodating greater density variations (e.g., chest structures including bone and lung). Window level sets the midpoint of this range, shifting brightness; for instance, a higher level brightens the image by centering on denser tissues. A common example is the bone window, using a center of 500 HU and width of 2000 HU to highlight cortical bone (>1000 HU) against softer structures, improving visualization of fractures or calcifications. Multiplanar reconstruction (MPR) enables the creation of reformatted images in non-axial planes from volumetric CT data, facilitating orthogonal views for better anatomical assessment. This technique relies on isotropic s—cubic elements with equal dimensions in all directions, typically achieved with multidetector CT scanners—to generate sagittal, coronal, or reformats without loss of . The process involves interpolating voxel data along the desired plane; for example, coronal reformats display head-to-toe slices from axial acquisitions, aiding evaluation of spinal alignment or pelvic structures. Curved MPR further allows tracing along non-linear paths, such as vessels, to unfold complex anatomies into a single plane. Volume rendering produces photorealistic visualizations by simulating light interaction within the volume, contrasting with 2D slice-based methods. The ray-casting algorithm is a foundational approach, projecting rays from each pixel through the volume and accumulating color and opacity contributions via at sampling points. Opacity transfer functions map scalar values to transparency levels, allowing selective rendering of surfaces (e.g., high-opacity for or exteriors) while making internal structures semi-transparent, thus revealing relationships like tumor encasement of vessels. GPU enables interactivity, with post-classification techniques minimizing artifacts for smoother surfaces. Projections such as maximum intensity projection (MIP) simplify 3D data into 2D images by selecting the highest value along each viewing ray, effectively highlighting contrast-filled vessels against surrounding tissues. In angiography, MIP excels at depicting vascular lumens without thresholding, preserving details for straightforward like the . Thin-slab MIP, using subsets of the volume (e.g., 10–20 slices), reduces overlap artifacts compared to full-volume projections, improving vessel conspicuity in regions like the . These techniques are often combined with editing tools, such as region-growing, to exclude bones or , ensuring clear vascular mapping.

Quality assessment and artifacts

Quality assessment in CT imaging evaluates the clarity and diagnostic utility of reconstructed images through key metrics such as and (CNR). , which determines the ability to distinguish fine structural details, is typically measured in line pairs per millimeter (lp/mm), where higher values indicate better performance; modern CT scanners achieve resolutions ranging from 1.0 to 1.6 lp/mm in the axial plane. CNR quantifies the detectability of differences between tissues and is calculated as CNR = \frac{|\mu_1 - \mu_2|}{\sigma}, where \mu_1 and \mu_2 are the mean attenuation values of two regions, and \sigma is the standard deviation of noise in the background; values above 3-5 are generally considered adequate for clinical interpretation. These metrics guide protocol optimization to balance detail preservation with practical scanning constraints. A fundamental challenge in CT is the trade-off between radiation dose and image quality, governed by the ALARA (as low as reasonably achievable) principle, which mandates minimizing patient exposure while ensuring sufficient diagnostic fidelity. Lower doses increase , reducing CNR and potentially obscuring subtle pathologies, but advancements like algorithms mitigate this by statistically modeling to suppress noise without compromising , enabling dose reductions of up to 50-75% in routine exams. Beam hardening artifacts arise from the polychromatic nature of X-ray beams, where lower-energy photons are preferentially absorbed by dense tissues, hardening the beam and causing cupping or streaking distortions that degrade Hounsfield unit accuracy. These effects are commonly corrected using pre-patient spectral filters, such as or aluminum, which attenuate low-energy photons to approximate a more monochromatic spectrum and improve uniformity. Metal streak artifacts, often due to photon starvation, occur when highly attenuating implants like hip prostheses severely reduce photon counts reaching detectors along certain projections, resulting in dark streaks and bright halos that obscure surrounding . This phenomenon is exacerbated in regions with metallic density exceeding 3000 Hounsfield units, leading to inconsistent profiles. Partial volume effects manifest when a voxel encompasses tissues of differing densities, averaging their attenuation values and producing blurred boundaries or erroneous densities, particularly at interfaces like bone-soft tissue transitions or in thin-slice imaging. This artifact can mimic , such as simulating lesions in uniform areas, and is minimized by thinner slice thicknesses or targeted oblique reformats. As of 2025, AI-driven denoising algorithms, particularly convolutional neural networks (CNNs), have emerged as powerful tools for enhancing low-dose images by reducing by up to 50% while preserving structural details, outperforming traditional methods in clinical trials for abdominal and chest protocols. These models train on paired low- and standard-dose datasets to predict denoised outputs, facilitating ALARA adherence without sacrificing interpretability.

Risks and safety

Radiation exposure

Computed tomography (CT) scans utilize , primarily X-rays, to generate cross-sectional images, resulting in patient exposure quantified through specific dosimetric units. The CT dose index volume (CTDIvol), measured in milligrays (mGy), represents the average radiation dose within the scanned volume for a standardized . The dose-length product (DLP), in mGy·cm, accounts for the scanned length by multiplying CTDIvol by the scan range. Effective dose, expressed in millisieverts (mSv), estimates the whole-body risk by applying (ICRP) tissue weighting factors to organ doses, enabling comparisons across procedures. Typical effective doses from CT scans vary by body region and protocol; a routine head CT delivers approximately 2 mSv, while an abdomen CT imparts about 10 mSv. These values represent averages for adult patients and can fluctuate based on scanner settings, patient size, and scan parameters. For context, the average annual natural exposure in the United States is around 3 mSv, so a single head CT equates to roughly two-thirds of a year's background, and an abdomen CT to over three years'. The primary health concern from CT radiation is stochastic effects, such as cancer induction, modeled by the linear no-threshold (LNT) framework, which assumes risk increases proportionally with dose without a safe threshold. Under this model, the lifetime attributable cancer risk is approximately 5% per (), or 0.005% per mSv, derived from epidemiological data like atomic bomb survivors and extrapolated to low doses via the Biological Effects of (BEIR) VII report. Deterministic effects, including tissue damage like or cataracts, require doses exceeding 500 mSv—far above typical CT levels—and thus pose no risk in standard diagnostic imaging. To minimize , especially in vulnerable populations, mitigation strategies include tailored pediatric protocols that adjust tube current, voltage, and scan range based on age and size to reduce doses by up to 50% compared to adult settings. (AEC) systems dynamically modulate tube current in real-time according to patient , optimizing dose while maintaining image quality and potentially lowering by 20-40% across various exams.

Contrast agent effects

Contrast agents, primarily iodinated compounds, are commonly administered during CT scans to enhance the visibility of blood vessels, organs, and tissues by increasing attenuation in areas of interest. Intravenous () iodinated contrast is the most frequent type used for vascular and parenchymal enhancement, while oral agents target gastrointestinal structures. Iodinated contrast agents for IV administration are classified as ionic (high-osmolar) or non-ionic (low-osmolar or iso-osmolar), with non-ionic agents now predominant due to their improved safety profile. High-osmolar ionic agents, such as , have osmolalities exceeding 1500 mOsm/kg, leading to higher and greater risk of adverse effects, whereas low-osmolar non-ionic agents, like or iopamidol, range from 500-850 mOsm/kg, resulting in lower for smoother injection and reduced physiological stress. Lower osmolality minimizes chemotoxicity and osmotic , contributing to fewer reactions compared to ionic types. For , suspensions provide high-density opacification of the bowel without systemic absorption, though water-soluble iodinated agents (e.g., ) are preferred in cases of suspected due to their absorbability and lower risk of complications like . is unsuitable for IV use, as it can cause severe tissue reactions if extravasated. IV contrast is typically delivered via power injectors at rates of 3-5 mL/s through an 18- to 20-gauge peripheral to ensure rapid bolus delivery and optimal enhancement. Injection volumes range from 100-150 mL based on patient weight (e.g., 100 mL for <75 kg, up to 150 mL for >90 kg), with saline chasers to maximize vascular opacification. Timing is critical for capturing specific enhancement s: early arterial at 15-25 seconds post-injection for vascular studies, late arterial at 30-40 seconds for , and portal venous at 70-80 seconds for abdominal evaluations. Bolus tracking or test boluses adjust for individual circulation times, ensuring synchronization with scan acquisition. Oral is given 30-60 minutes prior to scanning, often in volumes of 500-1000 mL, to allow bowel distension and coating. Adverse reactions to iodinated contrast are generally uncommon but range from mild to severe, with overall acute reaction rates of 0.2-0.7% for low-osmolar non-ionic agents. Mild reactions, such as nausea, vomiting, or limited urticaria, comprise the majority and occur in approximately 0.2-0.5% of cases, typically self-limiting without intervention. Moderate reactions, including diffuse hives or bronchospasm, occur in about 0.1% of cases and require treatment. Severe anaphylactoid reactions like laryngeal edema or hypotension occur in less than 0.1% (approximately 0.04% for life-threatening events). These hypersensitivity-like responses are not true allergies but may involve histamine release, with higher incidence in patients with prior reactions or asthma. Contrast-induced nephropathy (CIN), a form of acute kidney injury, poses a particular risk in patients with chronic kidney disease (eGFR <30 mL/min/1.73 m²), but for IV administration in CT scans, the incidence is low (<5%) and often not significantly higher than with non-contrast exams; higher risks (up to 20-30%) are associated with intra-arterial procedures. Prevention strategies include pre- and post-hydration with normal saline (e.g., 1 mL/kg/hour for 6-12 hours) and using low- or iso-osmolar agents. When iodinated contrast is contraindicated due to allergy or renal impairment, alternatives include limited use of gadolinium-based agents or non-contrast protocols. Gadolinium chelates, primarily for MRI, can be diluted for CT angiography but provide inferior attenuation (requiring higher doses) and carry risks like nephrogenic systemic fibrosis in CKD patients. Non-contrast CT remains viable for many indications, such as detecting hemorrhage or calcifications, relying on inherent tissue differences for diagnosis. In select cases, carbon dioxide or dilute iodinated agents may substitute, but their application is procedure-specific and less common in routine CT.

Advantages and limitations

Clinical benefits

Computed tomography (CT) scans offer significant clinical benefits in diagnostics due to their speed and accessibility, enabling rapid assessment within critical time windows such as the "" for patients. In cases, CT imaging can be completed and interpreted in minutes, facilitating the quick identification of life-threatening injuries like or organ damage, which directly supports timely interventions and reduces length of stay. This efficiency is particularly valuable in high-stakes scenarios, such as head and , where early detection can prevent secondary complications. The multi-modality capabilities of , including , enhance preoperative planning for surgery and by providing detailed volumetric images of anatomical structures. These reconstructions allow clinicians to visualize complex tumor geometries and surrounding tissues with high precision, enabling more accurate dose delivery in radiation oncology while minimizing exposure to healthy areas. In surgical contexts, such as , 3D CT models improve the assessment of lesion extent and vascular involvement, leading to safer procedures and better outcomes. CT scans demonstrate high for detecting specific pathologies, such as s and renal stones, often exceeding 95%. For acute , non-contrast CT achieves sensitivities of 90-100% when performed within the first 24 hours, making it the gold standard for initial evaluation. Similarly, for urolithiasis, non-contrast CT offers a sensitivity of approximately 97%, surpassing other modalities like in accuracy for stone detection and localization. In terms of cost-effectiveness, is particularly advantageous over MRI for acute cases, as it is faster to perform and generally less expensive, with average costs ranging from $500 to $3,000 compared to $1,200 to $4,000 for MRI. This makes a preferred initial imaging tool in time-sensitive emergencies, where MRI's longer scan times could delay care. Globally, over 375 million scans are performed annually as of 2024, reflecting their widespread adoption in clinical practice for efficient diagnostics.

Technical drawbacks

One significant technical drawback of CT scanning is its reliance on ionizing radiation, which accumulates with repeated exposures and poses long-term health risks despite the benefits of diagnostic imaging. Cumulative radiation from multiple CT scans has been associated with increased cancer risks in adults, highlighting the need for judicious use to minimize exposure. Additionally, CT provides inferior soft-tissue compared to (MRI), limiting its effectiveness in differentiating subtle tissue variations such as those in muscles, organs, or tumors without contrast agents. MRI excels in this area due to its superior ability to highlight differences between , , and other soft tissues. In obese patients, CT imaging faces challenges from limited X-ray beam penetration, leading to increased noise (quantum mottle) and beam-hardening artifacts that degrade image quality and hinder accurate diagnosis. These artifacts arise because thicker body habitus attenuates the beam more severely, reducing photon transmission and causing streak-like distortions, particularly in abdominal or thoracic scans. Such limitations can necessitate higher radiation doses or alternative imaging modalities to achieve diagnostic adequacy. Advanced scanners, especially multi-slice or photon-counting models, incur high acquisition costs, typically ranging from $1 million to $3 million, which restricts accessibility in resource-limited settings and contributes to overall healthcare expenses. These costs encompass not only the equipment but also maintenance and installation, making widespread adoption challenging for smaller facilities. Overutilization of CT scans often results in incidental findings—unrelated abnormalities detected during routine imaging—that prompt unnecessary follow-up tests, increasing patient burden and healthcare costs without clear clinical benefit. For instance, benign lesions identified on abdominal CT may trigger cascades of additional imaging or biopsies, exacerbating resource strain. Environmentally, CT operations contribute to significant energy consumption during scanning and cooling, with a single scanner potentially using thousands of kilowatt-hours annually, equivalent to substantial carbon emissions. Lead shielding materials, used for radiation protection in rooms and aprons, pose hazards through dust release and improper disposal, leading to contamination levels up to 34,000 mg/kg in stored areas and requiring specialized waste management.00553-8/pdf)

History and development

Invention and early milestones

The invention of the computed tomography (CT) scan is credited to British engineer , who developed the first practical system while working at Laboratories between 1967 and 1971. Independently, South African physicist Allan Cormack laid the mathematical foundations for image reconstruction in the late 1950s and 1960s, enabling the computation of cross-sectional images from projections. Their combined contributions revolutionized by allowing non-invasive visualization of internal body structures, earning them the 1979 Nobel Prize in Physiology or Medicine. The term "computed tomography" reflects its core principles: "computed" refers to the use of digital processing to reconstruct images, while "tomography" derives from the Greek words tomos (meaning "slice" or "section") and graphein (meaning "to write" or "to draw"), indicating the creation of slice-like images. Hounsfield's prototype produced its first clinical scan on October 1, 1971, at Atkinson Morley's Hospital in , imaging the brain of a with a suspected tumor and revealing a . This marked the debut of a technology that transformed diagnostics, particularly for . The first commercial CT scanner, the EMI Mark I introduced in 1972, was designed for head imaging only and featured a 80 × 80 pixel matrix, with scans taking approximately 5 minutes per slice using 160 projections. Limited to neurological applications initially, it demonstrated unprecedented detail in contrast without . The technology's potential spurred quick global interest, with the first U.S. installations occurring in 1973 at institutions like the . This led to rapid adoption, with body scanners introduced in 1975, expanding applications to include thoracic and abdominal imaging in major hospitals.

Technological evolution

The technological evolution of computed tomography (CT) scanners has transformed imaging capabilities, enabling faster scans, higher resolution, and reduced radiation doses since the . In the late , slip-ring technology was introduced, allowing continuous rotation of the and detectors without the need for physical cable connections, which facilitated the development of helical (spiral) scanning. This advancement eliminated the pauses required in earlier step-and-shoot axial scanning, enabling volumetric data acquisition over larger areas in a single breath-hold and improving efficiency for dynamic studies. Building on helical scanning, multi-slice CT emerged in the late 1990s, with the first systems acquiring four simultaneous slices in 1998, progressing rapidly to 16-slice configurations by 2000 and reaching 64 slices by 2004. These multi-detector row systems dramatically increased scan speed and spatial coverage, allowing isotropic voxel resolution and enabling applications like whole-body imaging and advanced cardiac protocols. In the 2000s, dual-source CT was introduced by Siemens in 2005, featuring two X-ray tubes and detectors offset by 90 degrees to achieve temporal resolutions as low as 83 milliseconds, particularly beneficial for cardiac imaging in patients with higher heart rates. Concurrently, dose reduction techniques advanced with GE's Adaptive Statistical Iterative Reconstruction (ASiR), launched around 2008, which uses statistical modeling to suppress noise in low-dose projections, enabling up to 40-50% radiation dose savings while maintaining diagnostic image quality. From the 2010s onward, innovations focused on spectral imaging and artificial intelligence integration. In 2021, Siemens Healthineers introduced the NAEOTOM Alpha, the first clinical photon-counting CT detector system, which directly counts individual X-ray photons to provide energy-specific data, enhancing material differentiation, reducing electronic noise, and improving low-contrast detectability at lower doses. AI-driven protocol optimization has automated scan parameter selection based on patient anatomy and clinical indications, minimizing overexposure. Deep learning reconstruction algorithms, such as those applied in coronary CT angiography, have further enabled over 40% dose reductions by generating high-quality images from ultra-low-dose acquisitions through trained neural networks that denoise and enhance features. As of 2025, photon-counting CT has seen expanded clinical adoption with additional FDA-cleared systems from vendors like and , alongside AI advancements for real-time motion correction and . These advancements have driven exponential growth in CT utilization, with global scan volumes rising from approximately 3 million annually in the early 1980s to over 375 million by 2024, reflecting broader accessibility and clinical adoption.

Society and technology

Prevalence and guidelines

In the , computed (CT) scan utilization has risen significantly, with approximately 93 million examinations performed in 2023, equating to roughly 279 scans per 1,000 annually based on a of about 333 million. Globally, an estimated 375 million CT scans are conducted each year, reflecting a 3-4% annual growth driven by increasing demand for diagnostic imaging in developed and emerging markets. Concerns over overuse persist, particularly in high-utilization countries like the , where rates exceed 250 scans per 1,000 people, potentially contributing to unnecessary and associated health risks. To address pediatric overuse, the Image Gently campaign, launched by the Alliance for Radiation Safety in Pediatric Imaging, promotes child-specific protocols to minimize radiation doses while maintaining diagnostic efficacy, emphasizing that unnecessary scans in children can elevate lifetime cancer risks. Broader public health efforts include the American College of Radiology (ACR) Appropriateness Criteria, evidence-based guidelines that rate imaging procedures by clinical scenarios to ensure CT scans are justified and optimized. Complementing this, the Choosing Wisely campaign, initiated by the ABIM Foundation in collaboration with medical societies, targets unnecessary CT use—such as in low-risk head trauma or routine —aiming to foster clinician-patient discussions and reduce low-value imaging by up to 20-30% in targeted areas. Regulatory and professional guidelines further standardize CT application, particularly in . The European Society of (ESR) provides essential recommendations for CT in , restaging, and response assessment, advocating standardized protocols to balance diagnostic accuracy with minimization. The ALARA (As Low As Reasonably Achievable) principle, endorsed by bodies like the Centers for Disease Control and Prevention, underpins these efforts by requiring facilities to optimize CT doses through techniques like and protocol adjustments, ensuring exposure remains below established thresholds without compromising image quality. Societally, access to CT scans reveals stark inequities, with underserved rural and low-income communities facing lower utilization rates due to limited and barriers, exacerbating outcome disparities in conditions like cancer and . Women bear higher lifetime cancer risks from due to biological factors like tissue sensitivity, and studies indicate varying utilization rates and gaps in awareness of risks.

Manufacturers and ongoing research

The major manufacturers of CT scanners include , Siemens Healthineers, Philips Healthcare, and Canon Medical Systems, which collectively dominate the global market. GE Healthcare's Revolution series features advanced dual-energy and photon-counting capabilities for high-resolution imaging, while ' SOMATOM lineup emphasizes spectral imaging and AI integration for diverse clinical applications. Philips Healthcare's Ingenuity systems focus on precision diagnostics with dose-reduction technologies, and Canon's Aquilion series incorporates rapid scanning and AI-assisted workflows. Together, these top four companies hold approximately 45% of the market share as of 2025. Ongoing research in CT technology centers on for automated reporting, where FDA-cleared tools since 2023 enhance efficiency by analyzing scans and generating preliminary findings. For instance, Qure.ai's qCT LN Quant, cleared in 2024, automates quantification on chest CTs to support faster oncologic assessments. Efforts in ultra-low-dose CT aim to reduce below 1 mSv while maintaining diagnostic quality, often leveraging denoising algorithms; recent studies as of 2024 have demonstrated feasibility for pulmonary nodule detection using hybrid and for evaluation in immunocompromised patients. Portable CT systems are also advancing for emergency room use, with ' SOMATOM On.site enabling bedside head imaging in ICUs and mobile units to expedite without patient transport. Clinical trials are exploring photon-counting CT for oncology applications, highlighting its superior spatial resolution for tumor delineation and metastasis detection. Ongoing 2025 trials, such as NCT07098247, explore photon-counting CT for enhanced target delineation in radiotherapy, while NCT06753903 assesses its role in detecting liver metastases from colorectal cancer. Spectral CT is being investigated for its performance in patients with metastatic colorectal cancer (NCT06024837). Looking ahead, research is integrating CT data with for training, allowing radiologists to manipulate 3D reconstructions interactively for better anatomical comprehension. Sustainability initiatives focus on scanner , with manufacturers like promoting refurbishment programs to reuse components and minimize , aligning with broader efforts to reduce the environmental footprint of equipment.