Fact-checked by Grok 2 weeks ago

Sip-and-puff

Sip-and-puff (SNP) is an interface that allows individuals with severe physical disabilities, such as quadriplegia, to control electronic devices like wheelchairs, computers, and communication systems by inhaling (sipping) and exhaling (puffing) through a small tube or mouthpiece connected to sensors. These sensors detect variations in air to generate binary signals—typically short and long sips or puffs corresponding to "on" and "off" or directional commands—enabling hands-free operation for users unable to use traditional manual inputs. The origins of sip-and-puff technology trace back to the early 1960s, when it was first integrated into the Patient Operated Selector Mechanism (), an early electronic communication aid prototyped by engineer Reginald G. Maling in the . The POSSUM system, detailed in a 1963 publication, used sip-and-puff controls alongside other inputs to allow tetraplegic patients to operate a and environmental controls via or scanning selection, marking it as one of the earliest electric aids for severe motor impairments. By the 1980s, the technology gained further prominence through adaptations like the one invented by Canadian engineer Bill Cameron for his cousin Neil Squire, a quadriplegic following a 1980 car accident; this version translated sips and puffs into for communication via a teletype machine, laying the foundation for the Neil Squire Society's ongoing work in assistive devices. Primarily applied to mobility aids, sip-and-puff systems are widely used in powered wheelchairs, where allows nuanced navigation through varying sip and puff intensities to mimic movements forward, backward, left, or right. In (AAC), they facilitate text generation and by selecting letters or words on screens, often combined with scanning interfaces for users with limited breath control. Beyond these, modern implementations extend to environmental controls (e.g., lights and appliances), computer access for web browsing and , and even emerging applications like robotic arms or adaptive gaming, with customizable sensitivity to accommodate respiratory variations. Despite advantages in , challenges include user fatigue from repeated breathing and the need for precise calibration, prompting ongoing into hybrid systems integrating sip-and-puff with eye-tracking or tongue controls for enhanced efficiency.

Fundamentals

Definition and Purpose

Sip-and-puff (SNP) is an assistive technology input method that detects changes in air pressure generated by a user's inhalation (sip) or exhalation (puff) through a mouthpiece, converting these actions into electrical signals to control electronic devices. This approach allows for binary or proportional control inputs based on the intensity and duration of the breath, making it suitable for operating interfaces that require simple on/off or directional commands. The primary purpose of SNP is to empower individuals with severe motor impairments to achieve greater by interfacing with that would otherwise be inaccessible due to limited manual dexterity. It facilitates the control of essential tools such as computers for communication and environmental controls, as well as mobility devices, thereby supporting daily activities and enhancing for users who retain sufficient respiratory function. SNP primarily serves people with high-level injuries, , , or other neuromuscular disorders that severely restrict arm and hand movement while preserving oral and respiratory capabilities. In the United States, between 250,000 and 390,000 individuals live with injuries as of 2025, with approximately 50% involving or similar severe mobility limitations that position SNP as a key assistive option; additionally, approximately 33,000 people are living with as of 2022, further expanding the potential user base. Emerging as a practical, low-cost, and non-invasive alternative to invasive neural interfaces, SNP originated to provide reliable device control without the need for surgical implantation, relying instead on straightforward air detection mechanisms.

Basic Principles

Sip-and-puff systems function by detecting variations in air produced through a user's oral or into a tube connected to a . , or "sipping," generates , while , or "puffing," creates positive . These pressure differentials arise from the and relaxation of respiratory muscles, altering the in the tube and displacing a or membrane in the , which in turn produces an electrical output proportional to the pressure change. The resulting electrical signals can be processed as outputs for discrete commands or as analog outputs for . In mode, a predefined is crossed to activate a switch-like event, such as a sip signaling "select" or a indicating "advance" in a . , by contrast, maps the magnitude and duration of the to variable inputs, enabling nuanced actions like adjusting device speed based on intensity. To reliably differentiate intentional user actions from incidental breathing fluctuations (which generate pressures below 5 cmH₂O), detection thresholds are calibrated to sensitivities around 7.5 cmH₂O above or below . Systems achieve response times of 50-200 ms, allowing for near-real-time signal generation while minimizing false positives through filtering algorithms that assess duration and stability. These processed signals integrate with target devices by emulating standard input mechanisms, such as momentary switches for on/off commands, joystick buttons for directional control, or USB Human Interface Device (HID) protocols for direct computer or wheelchair interfacing. This compatibility ensures seamless of oral pressure inputs into actionable device controls without requiring custom hardware modifications.

History

Early Invention

Sip-and-puff technology originated in the early with the development of the Patient Operated Selector Mechanism (), an early electronic aid for individuals with severe disabilities. Invented by electrical engineer Reginald G. Maling while volunteering at the National Spinal Injuries Centre at in , , POSSUM was prototyped in 1960 and commercialized in 1961. The system used a sip-and-puff mouthpiece to allow tetraplegic patients to control environmental devices such as lights, radios, telephones, televisions, and an electric through air pressure signals, often via or scanning selection. This innovation addressed post-World War II and needs, providing independent access to communication and daily controls for those with profound motor impairments. The technology emerged amid increased demand for mobility and communication aids due to spinal cord injuries among veterans and polio survivors. Early systems leveraged simple pneumatic components like tubing and pressure switches to convert breath into electrical signals, enabling hands-free operation without advanced electronics. Initial applications focused on basic on/off controls, particularly for powered wheelchairs, allowing users with limited upper body function to start, stop, and perform simple steering. This breath-operated alternative empowered independent navigation for polio and spinal injury patients, addressing critical post-war accessibility challenges.

Evolution and Advancements

In the late 1970s, the Rehabilitation Institute of Chicago, led by assistive device innovator Chuck Chevillon, advanced sip-and-puff systems for powered wheelchairs through licensing agreements that enabled based on breath intensity. This built on earlier pneumatic concepts, expanding applications to nuanced directional commands for enhanced mobility among individuals with severe disabilities. During the 1980s, engineer Bill Cameron invented a sip-and-puff communication device for his cousin Neil Squire, who had become quadriplegic following a 1980 car accident, allowing input through sips and puffs to generate text on a computer screen. This innovation, created using an adapted , facilitated independent messaging and laid groundwork for broader () tools. By the decade's end, such systems gained traction in settings, contributing to the establishment of organizations like the Neil Squire Society in 1984 to promote access. The 1990s and saw sip-and-puff integration with personal computers, including support for switch-based access in Microsoft Windows operating systems starting with versions like and expanding in accessibility options. Commercial products emerged, such as the QuadJoy mouth-operated controller with built-in sip-and-puff functionality, introduced around the early to enable hands-free control for users with limited mobility. Adoption milestones included increased FDA oversight of powered mobility devices under the 1990 Safe Medical Devices Act, which facilitated clearances for sip-and-puff-enabled wheelchairs as Class II medical devices, boosting their medical use. Concurrently, AAC standards evolved through organizations like the International Society for (), founded in 1987, promoting sip-and-puff as a core low-tech option in global guidelines by the . From the onward, advancements focused on hybrid systems combining sip-and-puff with eye-gaze tracking or brain-computer interfaces (BCIs) to improve accuracy and reduce , as demonstrated in research prototypes for and text entry. For instance, multimodal interfaces integrated sip-and-puff for selection with eye-tracking for pointing, addressing limitations like the "Midas touch" problem in gaze-only systems. Recent innovations include Puffin Innovations' Bluetooth-enabled sip-and-puff controller, launched in prototypes around and commercialized by , allowing control of toys, smartphones, and other devices via a universal app. These , portable designs have enhanced portability and compatibility, aligning with broader growth where sip-and-puff remains a foundational method in standards for severe motor impairments.

Technical Components

Hardware Elements

Sip-and-puff systems rely on a set of core components to capture and convert oral variations into usable signals. The mouthpiece functions as the primary , typically consisting of a straw-like that allows the to inhale () or exhale () into the device. These mouthpieces are often constructed from flexible or materials to ensure comfort and , with designs that can be bent or cut for optimal positioning near the user's mouth. Connected to the mouthpiece is flexible tubing, usually 1 to 2 meters in length, which transmits the air changes to the sensor unit. This tubing is pliable and equipped with simple twist or snap connectors for easy assembly and , enabling custom configurations for different user setups. At the heart of the system is the sensor, commonly a that detects variations in air pressure relative to ambient levels, often calibrated to thresholds of approximately 3 inches of (about 7.5 cmH2O) for standard operation. These sensors, such as those using micro-electro-mechanical systems () technology, generate electrical signals upon detecting sips (negative ) or puffs (positive ). Supporting elements include switch interfaces that convert the sensor's output into signals, typically via microswitches or 3.5 mm mono/ jacks compatible with assistive devices. Integrated amplifiers within sensors boost weak signals for reliable detection, while mounting —such as adjustable gooseneck arms with clamps or padded headsets—secures the system to wheelchairs, desks, or the user's head for hands-free use. Design variations accommodate diverse applications and user needs. Portable models, like USB-powered units, offer plug-and-play connectivity without external power requirements, while integrated head-mounted versions provide stability for mobile scenarios such as control. Battery-powered wireless configurations, utilizing for signal transmission, enhance mobility by eliminating tethered connections. Disposable mouthpieces and multi-user kits with snap-fit fasteners support shared environments. Safety features are integral to prevent health risks and ensure usability. Inline filters trap saliva and contaminants, with replaceable options extending system longevity and reducing infection transmission. Adjustable sensitivity settings, such as high-sensitivity modes at 2 inches of water column, allow customization to individual breath strength, often via dials or software-configurable thresholds on the sensor unit.

Software and Signal Processing

The software in sip-and-puff systems processes pressure signals from sensors to enable reliable user input interpretation. Analog pressure data, typically ranging from negative values for sips to positive for puffs, undergoes analog-to-digital conversion () via microcontrollers or dedicated processors to produce quantifiable digital signals for further analysis. This conversion facilitates precise measurement of breath intensity, often sampled at rates sufficient for response in assistive applications. Noise reduction is critical due to environmental variations and physiological inconsistencies, employing filtering algorithms such as moving averages to compute baselines from multiple readings and comparators to prevent erroneous triggers from minor fluctuations. Debounce mechanisms, including ramp times that require sustained pressure within defined zones, further stabilize inputs by ignoring transients, while thresholds—commonly set at approximately 3 inches of deviation from ambient—differentiate valid sips from puffs. Command mapping translates these filtered signals into actionable outputs, with software configurations assigning sips or puffs to specific functions like device activation or navigation. Many systems utilize (HID) protocols to emulate standard inputs, such as mouse clicks for selection or keyboard keys for text entry. Proportional control is achieved by analyzing pressure gradients or intensity levels, scaling outputs linearly—for instance, stronger puffs yielding higher speeds in wheelchair propulsion—enhancing granularity without additional hardware. Integration platforms ensure broad compatibility, with sip-and-puff inputs interfacing directly with operating systems like Windows through USB HID drivers and accessibility tools that support switch-based navigation. Specialized AAC software, such as Grid 3, incorporates sip-and-puff as a core alternative access method for symbol grids and environmental controls. Open-source libraries, including CircuitPython-based implementations for pressure sensor handling and repositories like the Sip-And-Puff-Analog-Switch project, allow customization for bespoke applications on platforms like . Advanced incorporates adaptive algorithms to refine performance over time, such as sequence-matching techniques that interpret user-defined patterns of short and long sips/puffs against a of commands, adjusting for variability in dynamics to reduce false positives in complex tasks like control.

Setup and Operation

The for sip-and-puff devices begins with proper mouthpiece positioning to ensure accurate air detection. The mouthpiece, typically connected via a short such as a 3.5mm or 1/8-inch , is placed securely near the user's , allowing for comfortable without , and routed to avoid kinks or interference. This step is performed by a healthcare or during initial setup to tailor the device to the user's oral positioning and prevent leaks that could affect readings. Next, baseline pressure measurements establish the user's normal breathing range, often referred to as the or neutral zone, to avoid unintended activations from passive . The user maintains relaxed breathing while the system records levels, typically on a 0-100 scale, to define non-command zones. Thresholds for and puff commands are then set through iterative trials, where the user performs soft and hard sips (inhalations) followed by soft and hard puffs (exhalations). Software wizards or sliders in built-in diagnostic modes capture these pressure bands, positioning thresholds midway between soft and hard levels—for instance, soft sip thresholds just above the and hard sip above that, with similar adjustments for puffs below . These adjustments accommodate varying user strengths, such as for individuals with weakened respiratory capacity. Tools for calibration include integrated software interfaces, such as those in the OMNI2 or LiNX systems, which provide visual via gauges or on-screen graphs for real-time verification. External sensors may supplement for precise measurement, ensuring thresholds exceed the by a minimum margin to filter noise. Depending on the number of trials needed for consistency, the process may vary in duration. Periodic re- is recommended following changes, such as or respiratory decline, to maintain reliability as user capabilities evolve. Common issues include over-sensitivity leading to false triggers from minor air movements, vibrations, or inconsistent breathing, which can be mitigated by fine-tuning thresholds, increasing ramp times for signal stabilization, or incorporating expansions. During , primary device functions like drive are often disabled to prevent accidents from erroneous inputs.

User Interface and Training

Sip-and-puff systems typically incorporate visual and auditory mechanisms to confirm user inputs and enhance . For instance, visual cues such as on-screen cursors that move in response to puffs or sips provide immediate confirmation of actions, while auditory signals like beeps indicate sip detection or mode changes. These elements help users with limited mobility verify their commands without relying solely on physical sensation. Interface designs often support customizable modes to accommodate different control needs, including single-switch patterns for basic on/off operations or dual-switch configurations for more complex interactions like directional navigation. Such flexibility allows integration with various devices, where users can adjust sensitivity thresholds for strength or puff duration to suit their respiratory capabilities. Training for sip-and-puff use follows progressive protocols, often beginning with simple on/off exercises to build familiarity before advancing to nuanced controls like varying puff duration for directional inputs. Initial sessions focus on activation under guidance from occupational therapists, who incorporate principles to ensure safe skill acquisition; proficiency typically develops over a few weeks. As proficiency grows, shifts to practical tasks, with therapists monitoring progress through structured programs like the Wheelchair Skills Training Program adapted for breath-based inputs. Adaptation strategies tailor the interface to users' varying abilities, such as implementing slower response times for beginners to reduce error rates during learning. Resources from organizations like the Neil Squire Society provide open-source guides for devices such as the LipSync sip-and-puff joystick, enabling customization for individual respiratory strengths and integration with touchscreens or environmental controls. Ergonomic considerations emphasize mouthpiece hygiene and fatigue prevention to support sustained use. Disposable mouthpieces or filters are recommended to prevent bacterial buildup and cross-contamination. Users are advised to routinely clean reusable mouthpieces and tubing with mild and after each session. To manage respiratory from repeated , which can occur during prolonged use, sessions should include breaks for recovery.

Applications

Wheelchair Control

Sip-and-puff systems enable directional of motorized through distinct breath patterns that translate air changes into signals. Typically, a strong puff commands forward motion, a strong sip directs reverse, while softer puffs and sips steer right and left, respectively. Proportional speed is often incorporated by varying breath intensity, allowing users to modulate velocity based on the force of or . Emergency stops can be triggered via specific patterns, such as a prolonged or double puff, ensuring rapid halting in critical situations. These systems integrate seamlessly with major wheelchair models, including those from Permobil and , via dedicated pneumatic modules that interface with the chair's electronics. Since the , drive-by-wire adaptations have facilitated sip-and-puff compatibility by replacing mechanical linkages with electronic signals, enhancing precision and reliability in power operation. Early implementations, such as those explored in rehabilitation engineering centers like Rancho Los Amigos in the late and early , demonstrated practical viability for controlled mobility. For users with quadriplegia, sip-and-puff control promotes significant independence by enabling self-directed indoor and outdoor navigation without reliance on caregivers, as evidenced by prototype systems from the 1960s that allowed users to traverse varied terrains. Enhancements like configurations pair sip-and-puff with head proximity sensors for finer adjustments, while modern sip-and-puff interfaces minimize cable entanglement and improve user comfort during extended use.

Computer and Communication Access

Sip-and-puff systems facilitate computer access for individuals with severe motor impairments by emulating standard input devices through breath-controlled switches. These devices detect variations in air pressure—sips for inhalation and puffs for exhalation—and translate them into digital signals compatible with USB interfaces on computers, tablets, and other platforms. For mouse emulation, a puff typically simulates a left-click to select items, while a sip can initiate drags or right-clicks, often in combination with cursor control methods like head tracking to enable navigation of graphical user interfaces. Keyboard emulation occurs via Morse-like sequences, where short sips represent dots and longer puffs represent dashes, or through integration with on-screen keyboards that highlight keys sequentially for selection. In augmentative and alternative communication (AAC), sip-and-puff interfaces drive speech-generating devices that convert selected text into synthesized speech output, supporting real-time verbal interaction. These systems incorporate word prediction algorithms to suggest completions based on partial inputs, minimizing the number of selections required and accelerating message formation, which is particularly vital for users with amyotrophic lateral sclerosis (ALS) who retain cognitive function but lose voluntary muscle control. Designs inspired by advanced switch-based AAC, such as those enabling precise selection for complex expression, adapt sip-and-puff for breath-only operation to generate full sentences or phrases. Evolution of these capabilities traces back to 1980s innovations in breath-operated communication aids that laid the groundwork for modern digital integration. Compatible software enhances usability, including Windows Ease of Access features that register sip-and-puff as switch inputs for on-screen keyboards and scanning interfaces. Hybrid setups with combine breath controls for navigation with voice recognition where feasible, while dedicated tools like SofType offer customizable layouts with macro expansion for frequent phrases. Scan-and-select modes, common in applications, present options in grids or rows that highlight progressively, allowing a puff to confirm choices and build text efficiently. With training, these configurations yield typing rates of 5-10 , empowering independent composition, web browsing, and document editing to foster greater autonomy in professional and personal communication.

Other Assistive and Recreational Uses

Sip-and-puff technology extends to environmental control systems, enabling individuals with severe motor impairments to manage home devices independently through breath-activated interfaces integrated with environmental control units (ECUs). These systems translate sips and puffs into commands for operating appliances, such as turning lights on or off via connected smart plugs. For instance, users can activate or deactivate plugged-in devices like lamps or fans by inhaling to select and exhaling to execute the action. Early integrations with the X10 protocol, a standard for , allowed sip-and-puff switches to control compatible modules for lighting and appliances, with documented implementations in assistive devices by the early . More recent adaptations pair sip-and-puff sensors with platforms like and voice assistants, such as Google Home, to command smart home functions including color-changing lights. In medical contexts, sip-and-puff interfaces support operation of adjustable beds and respiratory equipment, particularly for patients with limited mobility. The ASL 703 Six Function Sip and Puff Bed Control, for example, enables management of full electric hospital beds by using a sip to cycle through six positions (such as head elevation or knee adjustment) and a puff to activate the selected movement, providing precise control without manual input. For ventilator assistance, sip-and-puff modes deliver non-invasive support via a mouthpiece, allowing individuals with amyotrophic lateral sclerosis (ALS) to take deep recovery breaths during daytime activities without a full mask, thus improving comfort and mobility. In intensive care units (ICUs), these systems facilitate communication for intubated or mechanically ventilated patients by pairing sip-and-puff switches with speech-generating devices, enabling selection of needs like pain relief or adjustments throughout the day. Recreational applications leverage the versatility of sip-and-puff signals to promote leisure and , adapting everyday toys and games for users with . The introduced a sip-and-puff operated in 2016 as part of its Adaptoys initiative, where users steer via head motion sensors and propel the vehicle through breath commands, fostering family play for children and adults with quadriplegia. In , mouth-operated controllers like the QuadStick incorporate multiple sip-and-puff sensors to map breath actions to in-game inputs, such as using a puff for acceleration in racing simulations on platforms like PC or consoles. This setup allows precise control in first-person shooters and driving games, with customizable profiles ensuring compatibility across titles and enhancing immersion for players with high-level spinal cord injuries.

Advantages and Challenges

Benefits for Users

Sip-and-puff technology empowers users with severe mobility impairments, such as quadriplegia, by enabling greater autonomy in daily activities like navigation and device control. Studies indicate that this technology supports independence in (ADLs), with users reporting high satisfaction and continued adoption post-training, contributing to enhanced through restored functional capabilities. For instance, in adaptive applications, all participants with cervical spinal cord injury experienced significant improvements in perceived social connectedness (p < 0.001), highlighting its role in fostering participation and . Additionally, sip-and-puff systems are cost-effective, with basic switch interfaces ranging from $200 to $1,000, far more affordable than alternatives like eye-gaze systems, which often exceed $10,000. The inclusivity of sip-and-puff technology stems from its non-invasive design, relying solely on breath control without requiring surgical implantation or extensive physical exertion. This approach imposes minimal , as it uses simple binary inputs (sip for one action, puff for another) that are intuitive for users with limited motor function. Its portability further enhances daily usability, with compact headset or flex-tube configurations that integrate seamlessly into wheelchairs or communication devices for on-the-go access. Health outcomes for users include reduced dependency on caregivers, as sip-and-puff facilitates independent environmental control and mobility, thereby alleviating caregiver burden and promoting self-sufficiency. Evidence from 2020s research underscores decreased , with assistive breath-control systems enabling community engagement and communication that combat in tetraplegic individuals. The technology's adaptability to progressive diseases, such as or , allows for adjustments in sensitivity and mounting as motor function declines, ensuring sustained usability over time.

Limitations and Improvements

One primary limitation of sip-and-puff is its slow response time and low rate, typically ranging from 5 to 8 seconds per command with an efficiency of about 0.5 bits per second, which can hinder real-time applications such as or computer . Prolonged use often leads to user and discomfort due to the physical demands of sustained , making it cumbersome for extended sessions. Additionally, the technology is prone to false activations from external shocks or vibrations, which can compromise reliability in dynamic environments. The system's limited degrees of freedom restrict its versatility, confining users to basic binary or sequential commands that require memorization, potentially increasing cognitive load. Maintenance challenges, such as the need for frequent cleaning of mouthpiece tubes to prevent bacterial transmission, add to operational burdens. It is also unsuitable for individuals reliant on mechanical ventilators or diaphragm pacing systems, as these interfere with independent breath control. For communication tasks, sip-and-puff interfaces, such as those used in switch-based Morse code, exhibit low typing speeds averaging 2.1 words per minute, though peaks up to 12.4 wpm have been recorded in limited trials. Efforts to improve sip-and-puff systems include integrating microcontrollers, such as the ARM Cortex-M4, to enhance and enable precise control of diverse devices like virtual keyboards, electrical appliances, and adjustable beds through refined pressure detection via hysteresis comparators. Wireless adaptations, exemplified by sip-and-puff remotes for like the Apple , expand by supporting functions such as play, pause, and navigation without wired constraints. Multimodal hybrids combining sip-and-puff with eye-tracking or head arrays aim to boost speed and accuracy, addressing isolated modality limitations through complementary inputs. Future directions emphasize cost-effective designs for low-resource settings and non-contact alternatives, such as thermography-based breath detection, to reduce physical strain and broaden user suitability.

References

  1. [1]
    Understanding Assistive Technologies: What Are Sip-and-Puff ...
    Apr 28, 2023 · Sip-and-puff (or SNP) devices use air pressure to trigger specific commands. They may be useful for people with physical disabilities.Missing: history | Show results with:history
  2. [2]
    Assistive Technology Focus: Sip and Puff Devices - Accessible Web
    Oct 19, 2020 · Sip and Puff (or SNP) devices enable individuals who are unable to use a manual device to access computers and other essential technology. ...
  3. [3]
    An Aotearoa New Zealand contribution to assistive technology
    The POSM, Patient Operated Selector Mechanism, a typewriter with a “sip-and-puff” mouth controller, prototyped in 1960 by Reg Maling is believed to be the first ...
  4. [4]
    Electronic controls for the tetraplegic (possum) (patient operated ...
    Maling, R., Clarkson, D. Electronic controls for the tetraplegic (possum) (patient operated selector mechanisms—P.O. S.M.). Spinal Cord 1, 161–174 (1963).
  5. [5]
    History - Neil Squire Society
    Neil literally spoke through a “sip-and-puff (new window)” machine using Morse code and this code appeared as letters on a computer screen. These letters formed ...
  6. [6]
    A Boom in Assistive Technology Devices - PRIDE Industries
    Jul 13, 2020 · Sip-and-puff (SNP) technology is one such example. SNP was first developed in the sixties. It has long been used to allow people to operate ...
  7. [7]
    5 Things You May Not Know About the Early Days of AAC
    Oct 7, 2019 · Early AAC used communication boards in the 1950s, with the first project in 1964. The Talking Brooch was a wearable device in the 1970s, and ...
  8. [8]
    Supporting effective alternative access for individuals with physical ...
    Abstract. Alternative access methods accommodate an individual's specific physical disability, by adjusting the typical keyboard/mouse/touchscreen interface ...
  9. [9]
    Intelligent Control Wheelchair Using a New Visual Joystick - PMC
    Comparative study on different adaptation approaches concerning a sip and puff controller for a powered wheelchair. 2013 Science and Information Conference ...
  10. [10]
    Sip-and-puff – Knowledge and References - Taylor & Francis
    Sip-and-puff refers to a device or switch that is activated by sipping or puffing on a tube, allowing individuals who cannot move their hands to control a ...
  11. [11]
    Sip/Puff Switch - Origin Instruments
    The Origin Instruments Sip/Puff Headset is designed such that gravity will generally minimize saliva moving past the headset. If saliva gets past the headset ...Sip/Puff Switch · Sip/Puff Breeze
  12. [12]
    Sip and puff assistive technology | Variohm Group
    Sip and puff technology is an assistive technology that allows individuals with limited or no motor function in their limbs to control devices.
  13. [13]
    US Spinal Cord Injury Statistics
    Jan 8, 2017 · In the United States, there are currently between 240,000 and 337,000 people living with some type of spinal cord injury.<|control11|><|separator|>
  14. [14]
    Prevalence of Amyotrophic Lateral Sclerosis — United States, 2015
    Nov 23, 2018 · The 2015 estimated prevalence of ALS cases was 5.2 per 100,000 population, which is similar to the 2014 prevalence (5.0). The prevalence across ...
  15. [15]
    Sip-and-Puff Autonomous Wheelchair for Individuals with Severe ...
    Aug 9, 2025 · Multimodal input has the potential to enable users to perform ADLs without human assistance. We conducted 12 semi-structured interviews with ...
  16. [16]
    [PDF] Modern-Medical-Approaches-in-Neuromuscular-Disorders ... - EAMDA
    In “sip and puff” switches, often the lips are used to control which direction to move in. These advances provide those with NMD or other physical ...
  17. [17]
    Respiratory considerations in patients with neuromuscular disorders
    Aug 6, 2025 · ... pressure ventilation, commonly referred to as "sip and puff" ventilation. ... Higher pressure support (PS) of 14 cm H2O or more also called ...
  18. [18]
  19. [19]
    The science and engineering behind sensitized brain-controlled ...
    ... sip-and-puff” devices that translate air pressure from sucking or blowing on ... The resulting binary signal can be then used to control switches or to ...
  20. [20]
    None
    ### Summary of Sip-and-Puff Principles from https://digitalcommons.calpoly.edu/cgi/viewcontent.cgi?article=1179&context=cpesp
  21. [21]
    CircuitPython Powered Sip & Puff with ST LPS33HW Pressure Sensor
    2–3 day delivery 30-day returnsFeb 17, 2020 · Here, we show how with the right sensors, microcontrollers, and software, it can be relatively easy to make a very basic but expandable Sip and Puff device.Missing: threshold cmH2O
  22. [22]
    [PDF] Development of rehabilitation engineering over the years: As I see it
    development immediately after World War II. Rehabilita- tion engineering in ... In this picture she is shown using a sip and puff control straw to operate her ...
  23. [23]
    About Us - Northwestern University Prosthetics-Orthotics Center
    NUPRL contributed to the development of sip-and-puff control for motorized wheelchairs and communication devices, such as typewriters. Sip-and-puff control ...
  24. [24]
    CRT Pioneers and Innovators throughout History - LUCI Mobility
    Feb 9, 2021 · Chuck Chevillon + Rehab Institute of Chicago pioneers of the Sip-n-Puff control system. Chevillon coordinated the license of this technology ...
  25. [25]
    CLINICAL PERSPECTIVE - CEU ARTICLE - Issuu
    Dufco Electronics was the best known of the earlycommercial manufacturers of Sip-n-Puff systems.<|separator|>
  26. [26]
    (PDF) A journey through early augmentative communication and ...
    Aug 6, 2025 · Shown here is one that allowed control through sip and puff on a gooseneck mounted mouthpiece. ... Windows 3.1, but again as an add-on. With ...
  27. [27]
    QuadJoy
    QuadJoy has evolved to accommodate quadriplegia, spinal cord injury, ALS, muscular dystrophy/sclerosis, carpal tunnel, tendinitis and arthritis.Basic Operation · Edge Gestures · Newly Injured · Firmware Upgrade InstructionsMissing: 2000s | Show results with:2000s
  28. [28]
    A History of Medical Device Regulation & Oversight in the United ...
    Aug 21, 2023 · 1990: Safe Medical Devices Act (SMDA) · Improved postmarket surveillance of devices by: · Authorized the FDA to order device recalls and to impose ...Missing: sip- puff
  29. [29]
    [PDF] A multimodal interface to resolve the Midas-Touch problem in gaze ...
    The joysticks and sip-puff control devices are the most commonly used input ... O'Doherty et al., “Exploring gaze-motor imagery hybrid brain- computer ...
  30. [30]
    Puffin Innovations: Home
    Puffin is an all-in-one solution that empowers persons with disabilities to connect wirelessly to mobile devices, computers and anything smart.Missing: sip- | Show results with:sip-
  31. [31]
    Augmentative and Alternative Communication (AAC) Advances
    Augmentative and alternative communication (AAC) incorporates a wide range of processes that augment, complement, or replace speech of individuals with complex ...<|control11|><|separator|>
  32. [32]
  33. [33]
  34. [34]
    Breeze Specifications - Origin Instruments
    The Breeze was designed as a simple sip and puff switch; however, it uses a precision MEMS pressure sensor with integrated amplifier, digital calibration data.
  35. [35]
    US20170061784A1 - Sip-and-puff Controller of Electrical Devices ...
    A sip-and-puff controller that is operable to be coupled to the environmental control unit via a wireless communication path.Missing: origin | Show results with:origin
  36. [36]
  37. [37]
    [PDF] Multi-Controlled Wheelchair for Upper Extremities Disability
    Nov 17, 2018 · Sip-and-Puff Controller. The Sip-and-puff controller is an assistive technology that sends signals using air pressure by Sipping (inhaling) ...
  38. [38]
    Development of a Sip-and-Puff Interface for Communication and ...
    Aug 7, 2025 · A hysteresis comparator circuit converts pressure signals into digital commands of sip-and-puff. The ARM Cortex - M4 STM32F429 microcontroller ...
  39. [39]
    [PDF] Invacare® LiNX
    G and determined as hard puff. Sip and Puff Ramp Time. The Sip and Puff Ramp Time defines the amount of time that a pressure input must remain in the soft ...
  40. [40]
  41. [41]
    autonoME (Various Models) | GPII Unified Listing
    Grid 3 software with a custom grid set for ECU, AAC & computer access. ... The Dual: Microphone & Sip and Puff input device. Alert chime. Three (3) Z-wave ...
  42. [42]
    makersmakingchange/Sip-And-Puff-Analog-Switch - GitHub
    The Sip and Puff Switch has two 3.5 mm mono outputs so it can control two devices. The sip threshold and puff threshold are adjustable. The switch is powered by ...<|separator|>
  43. [43]
    Intuitive Sequence Matching Algorithm Applied To A Sip ... - RESNA
    In this paper, the algorithm is used in the context of the control of an assistive robotic arm and has been adapted to a sip-and-puff interface where short and ...<|control11|><|separator|>
  44. [44]
    [PDF] Omni 2 User Guide_ENGLISH - Magic Mobility
    Sip and puff calibration ... agent will perform the following calibration procedure to match the OMNI2 to your operating capabilities.
  45. [45]
    13046 | Industrial | Curtiss-Wright
    To Calibrate the Sip & Puff input use the following description: 1 - Press and hold the Select button on the Omni+ Controller whilst switching the unit on. 2 - ...
  46. [46]
    How to calibrate sip and puff
    ### Sip and Puff Calibration Summary
  47. [47]
    [PDF] Adapting to Changes in Breathing When You Have ALS
    “Sip and puff” refers to a second type of mouthpiece that can be used if you get short of breath with activities like talking or eating. Instead of using a ...Missing: calibration | Show results with:calibration
  48. [48]
    Sip and Puff Wheelchair Training Suite - Capstone Senior Design
    Sip and Puff (SnP) power wheelchairs provide a way for individuals with quadraplegia and individuals with low motor function to live independently. The chairs ...Missing: history | Show results with:history
  49. [49]
    A Sip-and-Puff Wireless Remote Control for the Apple iPod
    Aug 7, 2025 · Among the established breathing-based interaction techniques, the Sip-and-Puff system is notably prominent in assistive technologies [16, 36] .Missing: scholarly | Show results with:scholarly
  50. [50]
    Switches 101: Switches as Assistive Technology
    So we've got different sip and puff devices, grip and puff devices that you can try out. There're also lever switches or wobble switches. So we don't have ...
  51. [51]
    Take Home Technology Webinar - QLI
    Jun 3, 2022 · They also have sip and puff control. So if you either sip air in ... So this provides single or dual switch access via Bluetooth connection.<|separator|>
  52. [52]
    [PDF] 490E75=2_C - Dahl Engineering
    ”Sip & Puff”. For specific settings of the sip and puff control, e.g. puff pressure settings, sip and puff directions, etc. ”1-Switch scanner”. Adjustment of ...
  53. [53]
    Effectiveness of a Wheelchair Skills Training Program for Powered ...
    The Wheelchair Skills Training Program (WSTP) is a training protocol that draws on both the wheelchair literature (how to perform the skills) and the principles ...
  54. [54]
    [PDF] PM&R Assistive Technology Programs - polytrauma.va.gov
    how to “Enter” using the Sip and Puff. She could find the my way around with ... out at least 1-2 weeks, longer if needed equipment was not readily available.
  55. [55]
    [PDF] Effectiveness of a Wheelchair Skills Training Program for Powered ...
    A description of manual wheelchair skills training curriculum in. 462 entry-to-practice occupational and physical therapy programs in Canada. Disability and.
  56. [56]
    Welcome to LipSync V3.0 - Neil Squire Society
    Sep 2, 2021 · The LipSync is a sip-and-puff joystick that enables people with little or no hand movement to operate a touchscreen device.
  57. [57]
    Makers Making Change - Neil Squire Society
    ### Summary of Sip-and-Puff Devices, Training, Adaptation, or User Guides from Makers Making Change
  58. [58]
    Accommodation: Breath and Mouth Controlled Mouse - Disclo
    A Breath and Mouth Controlled Mouse, also known as a sip-and-puff mouse or ... Regularly clean the mouthpiece for hygiene and check the device for responsiveness.Missing: management | Show results with:management
  59. [59]
    Alternative ways to control a power wheelchair - ATandMe
    Jul 31, 2015 · HARD PUFF – Forward, SOFT PUFF – Right, SOFT SIP – Left and HARD SIP – Reverse. In some cases, it may be necessary to also connect an emergency ...
  60. [60]
    [PDF] Power Wheelchair Alternative Drive Controls in Spinal Cord Injury
    Sip-and-Puff: uses a straw device located in front of the user's mouth to provide a series of commands via different forces of “puffs” (positive pressure) ...
  61. [61]
    Sip and Puff Head Array - asl-inc.com
    Right and left turns are controlled by sensors located in the lateral wings of the Head Array. Steering or veering can be achieved by rotating the head toward ...
  62. [62]
    Sip & Puff System - This is Permobil
    The Sip & Puff System, available with a fiber optic switch, is designed for individuals with no upper extremity function.Missing: early development polio
  63. [63]
    [PDF] applications of space teleoperator technology to the problems of the ...
    for wheelchair control requires the patient to continually puff to maintain chair motion. If he stops puffing, the chair stops moving. However, the VAPC.
  64. [64]
    Review of NIDILRR's Rehabilitation Engineering Research Centers
    Sip and puff controls for electric wheelchairs [521]. KEI (Keyboard Emulating Interface) Standard and then commercial KEI's that enabled assistive technology ...
  65. [65]
    A Hierarchy of Driving Controls - Mobility Management
    Oct 1, 2017 · Sip and puff can also provide full control of the features of the wheelchair and allow independent driving as well. If the person can turn their ...
  66. [66]
    Alternative Drive and Mode Control Options | Education in Motion
    Jul 25, 2024 · Head Array Sip 'N Puff Combo · Pneumatic control allows for independent mobility when extremity and head control are insufficient. · Combo gives ...
  67. [67]
  68. [68]
    Telling tales: unlocking the potential of AAC technologies - PMC - NIH
    Dec 30, 2018 · Mechanical systems which gave access to typing for people with no hand function, such as the prototype POSM sip‐and‐puff electric typewriter ...
  69. [69]
    Understanding Success Criterion 2.1.1: Keyboard | WAI - W3C
    Keyboard emulators include speech input software, sip-and-puff software, on-screen keyboards, scanning software and a variety of assistive technologies and ...
  70. [70]
    Voice Recognition Solutions: Life at the Speed of Speech - Brain & Life
    ... sip-and-puff switch ... Doug has added functions through a second speech-recognition program, called KnowBrainer, that works with Dragon NaturallySpeaking.
  71. [71]
    SofType - Origin Instruments
    SofType is a full-function, advanced on-screen keyboard providing people with physical impairments access to their Windows computer ... Sip/Puff Switch.
  72. [72]
    Utilizing Assistive Technology for Environmental Control at Home
    May 4, 2025 · Sip-and-Puff Systems: Users control devices by inhaling (sip) or exhaling (puff) into a straw-like interface. Programmable Logic Controllers ...Missing: automation | Show results with:automation
  73. [73]
    Pneumatic demultiplexer for controlling multiple assistive technology ...
    ... sip-and-puff control. Multiple sip-and-puff tubes are difficult to ... control a TV 56, VCR 58, and X10 home automation devices 60. A powered chair ...
  74. [74]
    Sip & Puff Using Raspberry Pi With Google Home - Instructables
    Hey Google, turn the lights On. 2. OK Google, turn the light Off. 3. Hi Google, change the light into Red. 4. Hi Google, change the light into Blue. 5. Hi ...
  75. [75]
    ASL 703 Six Function Sip and Puff Bed Control
    The ASL 703 Six Function Sip and Puff Bed Control will allow control of a full electric hospital bed through the use of a Sip and Puff system.Missing: medical adjustment ventilator ICU
  76. [76]
    Ventilator Sip-and-Puff Mode - YouTube
    Jan 28, 2020 · This mouthpiece ventilation option allows you to take deep recovery breaths whenever you need them, without wearing a mask.
  77. [77]
    [PDF] Communication & The Mechanically Ventilated Patient - NCSRC
    Sep 26, 2013 · – Sip and puff. • Placement of device (e.g, access with head turn). • Pair with Speech Generating. Device. • Ensure access throughout day. • If ...
  78. [78]
    Christopher & Dana Reeve Foundation Presents Sip-and-Puff ...
    May 6, 2016 · A remote control car operated by a sip-and-puff headset. A voice-operated pitching machine that tosses pop-ups, groundballs and strikes.Missing: Puffin SNP
  79. [79]
    QuadStick
    The Quadstick FPS has a joystick, four sip/puff pressure sensors and a Lip position sensor which can be assigned to output to any game controller button or ...QuadStick FPS game controller · Shop · Downloads · DocumentationMissing: QuadJoy 2000s
  80. [80]
    Correct mouse and keyboard configuration for PC racing games?
    Dec 16, 2015 · With the QuadStick I know it's possible to play these games, and play them well, but I just can't seem to get the custom profile I've created ...
  81. [81]
    Effectiveness and acceptance of assistive technologies for people ...
    Oct 28, 2025 · Assistive technologies offer significant potential to improve the quality of life for individuals with tetraplegia. However, their real ...
  82. [82]
    Frontiers | Adaptive Esports for People With Spinal Cord Injury: New Frontiers for Inclusion in Mainstream Sports Performance
    ### Summary: Sip-and-Puff Technology in Adaptive Esports for Reducing Social Isolation
  83. [83]
    [PDF] A Comparative Study of Assistive Technologies for Physically ... - ijasre
    In the study, tongue drive system, eye tracer, voice recognition, and sip and puff technologies are compared to joystick assistive technology. The ...
  84. [84]
    Eye Gaze Devices - Link Assistive
    TD I-13 Gaze Interaction. Click for Price · TD I-16 Gaze Interaction. Click for Price · EyeMobile 5 ft Surface Pro. $8,225.00 · TD Pilot. $14,560.00.
  85. [85]
    (PDF) Intuitive, Myoelectric Control of Adaptive Sports Equipment for ...
    Nov 30, 2023 · All three measures indicate sEMG requires less cognitive load than Sip-and-Puff control. ... Surface electromyography (sEMG), a non-invasive ...
  86. [86]
  87. [87]
    Seating And Wheelchair Evaluation - StatPearls - NCBI Bookshelf
    These include chin control, sip-and-puff, speech control, or tongue control ... decrease reliance on caregivers and caregiver burnout, especially in the elderly.
  88. [88]
    ALS support: Assistive equipment and adaptations - ALS News Today
    May 26, 2023 · Power chairs can be driven by a joystick, head switches, chin-operated joysticks, or sip-and-puff controllers. Some power chairs are ...
  89. [89]
    (PDF) A Comparative Study of Assistive Technologies for Physically ...
    Aug 4, 2025 · In the study, tongue drive system, eye tracer, voice recognition, and sip and puff technologies are compared to joystick assistive technology.