Fact-checked by Grok 2 weeks ago

Thermal analysis

Thermal analysis is a group of techniques in which a property of a sample is monitored against time or temperature while the temperature of the sample, in a specified atmosphere, is programmed. These methods measure changes in physical or chemical properties, such as mass, heat flow, or dimensions, to characterize materials under controlled thermal conditions. Originating from early calorimetric experiments around 1789 by Lavoisier and formalized as thermal analysis in 1887 by Le Châtelier, the field has evolved into an interdisciplinary domain essential for and related disciplines. The historical development of thermal analysis accelerated after with advancements in , signal recording, and , leading to standardized nomenclature by the International Confederation for Thermal Analysis (ICTA) following its inaugural conference in 1965, with the organization later renamed the International Confederation for Thermal Analysis and (ICTAC) in 1992 to integrate . Key milestones include the introduction of (DTA) in 1899, thermogravimetry in 1915, and (DSC) in the mid-20th century, driven by needs in industries like and polymers. Today, the field continues to advance with sample-controlled thermal analysis (SCTA) and coupled techniques like thermogravimetry-mass spectrometry (TG-MS), supported by computational tools for kinetic modeling. Prominent techniques in thermal analysis include: These methods often employ kinetic models, such as isoconversional approaches (e.g., Kissinger-Akahira-Sunose or Flynn-Wall-Ozawa), to analyze reaction rates and activation energies without assuming specific mechanisms. Applications of thermal analysis span diverse fields, including polymer characterization for thermal stability and vulcanization in the rubber industry, phase fraction determination in metallurgy, and stability assessment in pharmaceuticals. In ceramics and glass manufacturing, it optimizes firing processes and studies devitrification, while in energy sectors, it evaluates fuel decomposition and catalyst performance. Biological and environmental uses include analyzing enzymatic reactions, flame retardants, and even ancient artifacts like papyrus for degradation studies, underscoring its role in quality control, research, and process optimization.

Fundamentals

Definition and principles

Thermal analysis (TA) encompasses a group of techniques that measure the physical or chemical properties of materials—such as mass, dimensions, heat flow, or mechanical response—as a function of (or time) while the sample is subjected to a controlled heating or cooling program. These methods reveal how materials respond to thermal stimuli, enabling the characterization of stability, transitions, and reactions under defined conditions like programmed rates and atmospheres. At its core, thermal analysis relies on principles from and , focusing on phenomena like , phase transitions, thermal , and . , a measure of the energy required to raise the of a , is quantified by q = m C_p \Delta T, where q is the heat transferred, m is the mass, C_p is the at constant , and \Delta T is the change; this property helps identify baseline thermal behavior before transitions occur. Phase transitions, such as or , involve changes in molecular order and are classified as endothermic (absorbing heat, e.g., disrupts lattice structure) or exothermic (releasing heat, e.g., forms ordered structures). Thermal assesses resistance to degradation, while tracks bond breaking, often linked to molecular structure—stronger intermolecular forces delay transitions, and reaction govern the rate of these events under thermal . Measurements in thermal analysis use standardized units, including (K) or degrees (°C) for , watts () or milliwatts (mW) for heat flow (often normalized as mW/), and milligrams () for sample mass, ensuring comparability across studies. Controlled atmospheres, such as inert gases (e.g., ) to prevent oxidation or oxidative environments (e.g., air) to simulate real-world conditions, significantly influence outcomes by altering reaction pathways and events. These principles provide foundational insights into how molecular and kinetic barriers dictate behavior, prerequisite for interpreting technique-specific data without requiring detailed instrumentation knowledge.

Historical development

The foundations of thermal analysis lie in the late 18th and early 19th centuries, when scientists began systematically studying heat effects through . Antoine and Pierre-Simon invented the ice calorimeter in the 1780s to quantify heat production in chemical reactions and , laying groundwork for measuring thermal changes in materials. These early efforts focused on thermometry to observe phase transitions and heat capacities, influencing later quantitative techniques. A pivotal milestone occurred in 1887, when French chemist Henri Le Chatelier developed the first (DTA) apparatus to investigate thermal events during the firing of clays, such as kaolin and halloysite. Le Chatelier's method involved recording temperature differences between a sample and an inert reference during controlled heating, enabling detection of endothermic and exothermic processes like and phase changes. This innovation, initially applied to ceramic materials, established DTA as a core thermal analysis technique and inspired subsequent refinements, including thermocouple-based systems by researchers like William Chandler Roberts-Austen in 1899. In the mid-20th century, (TGA) saw significant advancements and commercialization, particularly for monitoring mass changes during under heat, building on its initial development in 1915 by Japanese metallurgist Kôtaro Honda, who created the first thermobalance for studying thermal stability in high-temperature inorganic materials such as metals and ceramics. Concurrently, (DSC) was theorized and invented in 1962 by E.S. Watson and M.J. O'Neill at , introducing power-compensated to directly measure heat flow differences between sample and reference. commercialized the DSC-1 instrument in 1963 at the Pittsburgh Conference on and Applied Spectroscopy, accelerating its adoption for precise determinations. The establishment of the International Confederation for Thermal Analysis (ICTA) in 1965 during its inaugural conference in , , marked a key organizational milestone, fostering global collaboration and later evolving into the International Confederation for Thermal Analysis and Calorimetry (ICTAC) in 1992. ICTA promoted standardized terminology and practices, including nomenclature committees that influenced subsequent guidelines. In the modern era, post-1980s advancements integrated thermal analysis with hyphenated techniques, such as coupled with (), building on early 1960s experiments like those by Zitomer in 1968 to identify evolved gases during decomposition. This evolution enabled detailed mechanistic studies, with becoming routine for volatile analysis in by the 1990s. By the 2000s, instruments shifted toward and high , exemplified by TA Instruments' Q-Series DSCs and , which incorporated software-controlled stepwise isothermal modes for enhanced decomposition . Standardization efforts intensified in the 1970s and 1990s through bodies like and the (ISO). ASTM E967, first issued in the late 1970s for DSC temperature calibration using metal standards like , ensured reproducible onset measurements. Similarly, ASTM E1131 (1990s) standardized TGA procedures for plastics, while ISO developed complementary norms, such as ISO 11358 for of polymers, promoting harmonized testing protocols across industries. These standards, informed by ICTAC recommendations, solidified thermal analysis as a reliable quantitative tool.

Techniques

Differential scanning calorimetry (DSC)

Differential scanning calorimetry (DSC) is a thermoanalytical that measures the difference in between a sample and an inert reference material as they are subjected to a controlled program. This method quantifies the energy absorbed or released during thermal events such as phase transitions, allowing for the determination of thermodynamic properties like and changes. Developed in the early 1960s, DSC provides quantitative data on heat flow rates, distinguishing it from earlier (DTA) by delivering absolute calorimetric measurements rather than relative temperature differences. DSC instruments operate in two primary modes: power-compensated and heat-flux. In power-compensated DSC, the sample and reference are placed in separate furnaces, where independent heating elements maintain them at the same temperature; any difference in electrical power supplied to the sample furnace compensates for endothermic or exothermic events, directly yielding heat flow data. Heat-flux DSC, by contrast, uses a single furnace with the sample and reference positioned on a shared thermoelectric disk or platform; heat flow is measured via the temperature difference (ΔT) across a thermal resistor using the relation q = ΔT / R, where q is the heat flow rate and R is the thermal resistance. Typical instrumentation includes sample pans made of aluminum (open or hermetic to contain volatiles) holding 1–20 mg of material, a purge gas such as nitrogen to maintain an inert atmosphere and facilitate heat transfer, and temperature ranges spanning -180°C to 700°C, depending on the model. Scan rates, commonly 10°C/min, influence peak resolution and transition temperatures, with slower rates improving accuracy for subtle events like glass transitions. The enthalpy change (ΔH) associated with a thermal transition is calculated by integrating the excess heat flow (after baseline subtraction to remove the underlying heat capacity contribution) over temperature or time. For discrete events like melting, this involves peak area integration. Endothermic transitions, such as melting (T_m) or glass transition (T_g)—the latter appearing as a baseline step increase in heat capacity—are represented as upward peaks in heat-flow thermograms (convention varies by instrument), while exothermic events like crystallization (T_c) show downward peaks. Factors like scan rate affect resolution; for instance, faster rates broaden peaks and shift T_g to higher temperatures due to kinetic limitations. In data interpretation, baseline construction is critical for accurate ΔH_m quantification, often using linear or sigmoidal fits between pre- and post-transition regions. For purity assessment in pharmaceuticals, DSC applies the Van't Hoff equation to analyze melting point depression caused by impurities, using fractional melting plots of temperature versus the reciprocal of the melted fraction to determine impurity levels. DSC complements techniques like thermogravimetric analysis (TGA) by providing energetic insights into transitions, while TGA addresses mass changes.

Thermogravimetric analysis (TGA)

Thermogravimetric analysis (TGA) measures the mass of a sample as a function of or time under a , providing insights into thermal stability, pathways, and material composition. The technique utilizes a precision microbalance integrated into a system, where the sample is heated or held at specific conditions while continuously recording mass changes. These changes arise from processes such as , desorption, , or oxidation, enabling the quantification of volatile content, residue formation, and reaction kinetics. Decomposition in TGA follows kinetic models, commonly described by the for the rate constant k = A \exp\left(-\frac{E_a}{RT}\right), where A is the , E_a is the , R is the , and T is the absolute temperature. Activation energy is determined from mass-loss curves through methods like isoconversional analysis, involving multiple dynamic experiments at varying heating rates to plot parameters such as \ln(\beta / T^2) versus $1/T, where \beta is the heating rate; the slope yields -E_a / R. Mass-loss profiles often reveal multi-stage processes, with percentage losses indicating fractions like volatiles or char residue, essential for compositional analysis. TGA operates in two primary modes: dynamic, involving a programmed ramp (typically 5–20 °C/min) to assess overall behavior, and isothermal, maintaining a fixed to evaluate reaction rates and over time. In dynamic mode, initial mass loss quantifies content (often below 150 °C), followed by volatile organics and eventual residue like ash above 500 °C. Isothermal measurements facilitate lifetime predictions by modeling under service conditions. Instrumentation features a high-sensitivity electrobalance with resolution as fine as 0.1 μg, supporting sample masses of 1–100 mg in pans made of , alumina, or to withstand corrosive environments. The furnace, often with a range of ambient to 1500 °C, incorporates controlled gas purging (e.g., 50–100 mL/min of air, , or ) to define oxidative, inert, or reducing atmospheres. For detailed decomposition product identification, TGA couples with evolved gas analysis (EGA) via (FTIR) or (MS), transferring gases through heated lines for real-time spectral analysis. Data analysis generates thermograms plotting mass (or percentage) versus or time, supplemented by derivative thermogravimetry (DTG) curves that differentiate the mass signal to highlight the rate of change. DTG peaks pinpoint maximum temperatures (T_{\max}), aiding in resolving overlapping stages and correlating with kinetic parameters. Quantitative residue determination, such as content, derives directly from the final mass plateau after correcting for and baseline drift.

Differential thermal analysis (DTA)

(DTA) is a thermoanalytical technique that measures the difference () between a sample and an inert material, such as alumina, as both are subjected to a controlled programmed heating or cooling in a single . This setup allows for the detection of thermal events in the sample, where heat absorption or release during phase transitions or causes the sample to deviate from that of the . The method is particularly valued for its and ability to identify the onset and nature of processes without requiring separate calorimetric cells. The fundamental principle relies on the relationship between the temperature difference and the thermal properties of the sample. Specifically, the differential temperature is given by \Delta T = \frac{\Delta C_p}{G} \beta where \Delta C_p is the difference in heat capacity between the sample and reference, G is the thermal conductance of the sample holder to the furnace environment, and \beta is the linear heating rate. This equation highlights how ΔT is directly proportional to the heating rate and inversely to the thermal conductance, enabling the qualitative assessment of energy changes during thermal events. In DTA, thermal events are detected through characteristic peaks on the ΔT versus temperature plot. Endothermic processes, such as dehydration or melting, produce negative ΔT peaks as the sample cools relative to the reference due to heat absorption. Conversely, exothermic events, like oxidation or crystallization, generate positive ΔT peaks as the sample heats up from heat release. These peaks provide qualitative information on the temperature at which events occur, though peak shape and area can vary with factors like sample mass and particle size. Classical DTA focuses on qualitative event detection, while quantitative variants incorporate to estimate changes from peak areas. Typical setups employ thermocouples positioned near the sample and reference holders—often in or crucibles—to measure temperatures accurately, supporting ranges from ambient up to 1600°C, which is ideal for studying and materials. DTA offers advantages in high-temperature applications due to its straightforward single-furnace design, which is simpler and more robust than (DSC) for analyzing materials where precise heat flow measurement is challenging. Baseline drift, often caused by uneven heating or changing thermal conductivities, can be corrected using techniques such as employing metallic blocks as references or dynamic baseline subtraction during . This evolution toward quantitative analysis has paved the way for techniques like DSC, which build on DTA principles for absolute heat measurements.

Dynamic mechanical analysis (DMA)

Dynamic mechanical analysis (DMA) is a thermal analysis that evaluates the viscoelastic properties of materials by applying a sinusoidal oscillatory force to a sample and measuring its deformation response as a function of , , or time. This method probes key mechanical characteristics, including the storage modulus (elastic response) and loss modulus (viscous dissipation), along with damping behavior, providing insights into molecular mobility and relaxation processes. DMA is particularly sensitive for detecting transitions in polymers and composites, offering advantages over static methods by quantifying energy storage and dissipation under dynamic conditions. The fundamental principles of DMA rely on the viscoelastic nature of materials, where the applied \sigma(t) = \sigma_0 \sin(\omega t) elicits a response \epsilon(t) = \epsilon_0 \sin(\omega t - \delta), with \delta as the indicating the balance between elastic and viscous components. The storage E', which measures the recoverable , is defined as E' = \frac{\sigma_0}{\epsilon_0} \cos \delta; the loss E'', representing energy dissipation as heat, is E'' = \frac{\sigma_0}{\epsilon_0} \sin \delta; and the \tan \delta = \frac{E''}{E'}, which peaks at relaxation events like the temperature T_g. These parameters, derived from the E^* = E' + iE'', enable of and internal across varying conditions. DMA operates in multiple deformation modes to accommodate diverse sample geometries, including for films and fibers, for bulk , for liquids and soft materials, and torsion for cylindrical samples, allowing tailored testing of tensile, flexural, or torsional properties. sweeps typically span 0.01 Hz to 100 Hz or higher (up to 200 Hz in advanced systems), while temperature ramps cover -150°C to 600°C, enabling the study of low-temperature relaxations to high-temperature decompositions. These ranges facilitate the separation of time-dependent and thermal effects on material behavior. Instrumentation for DMA includes precision clamps and fixtures, such as film tension grips or single/double setups for thin samples, integrated with a drive motor for oscillatory loading and transducers for force and displacement detection. An provides controlled heating/cooling rates (often 1–5°C/min) and optional or atmospheres to simulate service conditions. Multifrequency temperature scans support time-temperature superposition (TTS), where data at different frequencies and temperatures are shifted to construct master curves predicting long-term viscoelastic performance over decades. In data interpretation, DMA curves reveal sub-ambient transitions in polymers, such as secondary relaxations (e.g., transitions in around -50°C), through drops in E' and peaks in \tan \delta, indicating localized molecular motions. For curing kinetics, isothermal time sweeps track the evolution of during reactions, as seen in systems where E' increases from low values (~1 MPa) in the liquid state to rigid levels (~3 GPa) post-cure at temperatures like 35°C and 1 Hz frequency. These analyses highlight DMA's role in optimizing material processing and performance without relying on complementary thermal stability assessments.

Thermomechanical analysis (TMA)

Thermomechanical analysis (TMA) is a thermal analysis technique that measures the dimensional changes of a as a function of , time, or applied force under controlled conditions, providing insights into , softening, and other thermomechanical behaviors. In TMA, a sample is subjected to a minimal static load while being heated or cooled in a , and a probe tracks changes in , , or penetration depth, typically in an inert or to minimize oxidative effects. This method is particularly suited for evaluating the and response of solids, liquids, or pasty materials to variations, with applications spanning polymers, ceramics, and composites. The core principle of TMA revolves around quantifying under non-oscillating stress, where the linear coefficient of (α), a key parameter, is calculated using the equation \alpha = \frac{1}{L_0} \cdot \frac{\Delta L}{\Delta T}, with L_0 as the initial length, \Delta L as the change in length, and \Delta T as the temperature change, often measured at constant . Measurements can be linear, focusing on one-dimensional or , or volumetric, assessing three-dimensional changes via specialized probes to derive the coefficient of volumetric expansion (γ = α_x + α_y + α_z). Load ranges typically span 0.001 to 2 with a force of 0.001 , while sensitivity reaches below 0.5 , enabling precise detection of subtle dimensional shifts. In penetration mode, TMA determines softening points by monitoring probe intrusion into the sample under a light load, revealing transitions like melting or glass softening. Instrumentation in TMA generally includes a probe—chosen for its low (approximately 0.5 μm m⁻¹ K⁻¹)—positioned on or within the sample, supported by a stable platform inside a vertical capable of temperatures from -150°C to 1000°C. A (LVDT) or similar , often combined with an optical encoder for enhanced accuracy, records probe displacement, while software processes data to generate curves. Modes are adapted for sample types: mode for rigid, flat solids (0.5–2.5 mm thick) to measure coefficient of (); tension mode for fibers or films (20–200 μm thick); and penetration or flexure for softer or powdered materials, accommodating irregular shapes like powders via compression fixtures. TMA finds specific utility in characterizing sintering shrinkage, where irreversible dimensional contraction during heating is quantified to optimize ceramic or polymer processing, often showing shrinkage rates up to several percent in oriented materials. It also identifies glass transition temperatures (T_g) through inflections in expansion curves, marking the shift from glassy to rubbery states, as seen in polymers where the curve's tangent intersection highlights this onset. These static measurements under low load complement dynamic assessments of viscoelastic properties, such as those in (DMA), by focusing on baseline dimensional stability.

Applications

Polymers

Thermal analysis techniques are essential for characterizing polymers, providing insights into molecular structure, phase transitions, thermal stability, and processing behavior. These methods reveal key properties such as transitions, kinetics, points, and mechanisms, which influence mechanical performance, processability, and end-use applications in materials like thermoplastics and thermosets. By monitoring heat flow, mass changes, or dimensional variations under controlled programs, researchers can quantify transitions that govern behavior, such as the shift from glassy to rubbery states or the onset of chain scission. The temperature (T_g) marks the temperature range where amorphous polymers from a rigid, glassy state to a flexible, rubbery one, and it is determined using (DSC) and (DMA). In DSC, T_g appears as a step change in , with the midpoint defined as the intersection of the baseline and lines to the curve, offering a precise measure for unfilled polymers like at approximately 148°C under a 20°C/min heating rate. DMA detects T_g through mechanical property changes, identifying it at the peak of the loss (tan δ), which corresponds to maximum energy dissipation and occurs at higher temperatures, such as 151.5°C for at 1 Hz and 3°C/min. Factors like molecular weight influence T_g; for blends or copolymers, the Fox-Flory equation approximates the overall T_g as \frac{1}{T_g} = \frac{w_1}{T_{g1}} + \frac{w_2}{T_{g2}}, where w_i are weight fractions and T_{gi} are component T_g values, reflecting compositional effects on chain mobility. For semicrystalline polymers, DSC identifies crystallization temperature (T_c) as an exothermic peak during cooling and temperature (T_m) as an endothermic peak during heating, providing data on thermal history and ; in (PET), T_m typically exceeds 200°C, while T_c appears below it depending on cooling rate. The degree of crystallinity (X_c) is calculated from the enthalpy as X_c = \frac{\Delta H_m}{\Delta H_m^0} \times 100\%, where ΔH_m is the measured and ΔH_m^0 is the for 100% crystalline polymer (144.7 J/g for PET), yielding values like 25% for PET cooled at 10°C/min. Thermogravimetric analysis (TGA) assesses polymer thermal degradation by tracking mass loss with temperature, identifying onset temperatures where significant decomposition begins; for poly(vinyl chloride) (PVC), multi-step mass loss occurs, with dehydrochlorination—the elimination of HCl—starting around 250–273°C and leading to conjugated polyene formation. This process accounts for the initial ~60% mass loss, followed by further degradation to aromatic residues. Oxidative stability is evaluated by comparing TGA curves in air versus inert atmospheres like ; in air, oxidation accelerates degradation above 300°C, causing additional mass loss due to chain scission and char formation, whereas reveals purely thermal pathways. Thermal analysis informs processing, particularly cure kinetics in thermosets via isothermal scans, where heat flow is monitored at constant temperatures to model reaction progress using equations like \frac{d\alpha}{dt} = k \alpha^m (1-\alpha)^n for autocatalyzed systems, enabling prediction of gelation and times in epoxies. For blends, and compatibility are assessed through T_g shifts or broadening in , indicating or interaction between components that affects processing windows and final properties. Specific examples illustrate these applications: (TMA) measures linear expansion in to determine coefficient of (CTE), relating it to variations, as (LDPE) shows expansion of approximately 100-200 μm/m/°C below melting and relates higher to reduced swelling during thermal cycling. In rubber vulcanization, tracks the rise in storage from initial low values (~1 MPa) to higher levels (~10 MPa) post-crosslinking, reflecting network formation in under or systems, with higher indicating greater crosslinking .

Metals and alloys

Thermal analysis techniques are essential for investigating the thermal behavior of metals and alloys, focusing on reversible phase changes driven by , such as , solidification, and allotropic transformations, which differ from the irreversible processes seen in other materials. (DSC) and (DTA) provide precise measurements of enthalpic changes during these events, while (TGA) and (TMA) assess stability and mechanical integrity under . These methods enable the determination of critical parameters like transition temperatures, latent heats, and kinetic rates, informing design, , and in high-temperature environments. In the study of melting and solidification, DSC quantifies the latent heat of fusion for pure metals by integrating the endothermic peak during heating. For example, pure aluminum exhibits a of 660°C with a latent heat of approximately 397 J/g, reflecting the energy required to disrupt its crystal lattice. In binary or multicomponent alloys, DSC identifies eutectic points through the onset of sharp peaks, where the liquid phase forms at a temperature lower than that of the constituent metals, facilitating controlled solidification microstructures. Phase transformations in metals, such as allotropic changes, are effectively characterized using DTA, which detects thermal effects from structural rearrangements without significant loss. A prominent example is the α-to-γ in iron at 912°C, where the body-centered cubic structure shifts to face-centered cubic, influencing magnetic and mechanical properties during processing. Additionally, cooling curves derived from DTA or during solidification provide insights into kinetics, revealing rates and growth mechanisms through the undercooling observed in the exothermic peaks. Purity assessment in metals relies on to measure melting point depression caused by solute impurities, analyzed via the shape of the melting curve using the van't Hoff equation. This method, standardized in ASTM E928, allows quantification of impurities as low as 0.1% by analyzing the broadening and shift of the melting peak. complements this by evaluating oxide inclusions, where non-volatile residues remaining after high-temperature treatment in inert or reducing atmospheres indicate the content of refractory oxides like alumina or silica in the metal matrix. Oxidation and thermal stability are probed via TGA, which records mass gain from oxygen uptake during exposure to air at elevated temperatures, signaling corrosion onset and scale formation. For instance, low-alloy steels show noticeable mass gain starting around 500°C due to the formation of iron oxides, with the rate depending on alloying elements like chromium. High-temperature TMA extends this analysis by measuring dimensional changes under load, quantifying creep deformation in metals like nickel-based alloys, where steady-state strain rates inform service life predictions in turbine components. Practical applications include the characterization of , such as Sn-Pb or Sn-Ag-Cu systems, where determines melting ranges (e.g., 183°C for eutectic Sn-Pb) to ensure reliable joint formation in electronic assemblies. In superalloys, DTA evaluates precipitate dissolution, as seen in 718 where γ′ phase solvus temperatures around 1000–1100°C are identified from endothermic peaks, guiding for optimal microstructure.

Food products

Thermal analysis techniques play a crucial role in for assessing quality, stability, and processing conditions of edible products. (DSC), (TGA), (DMA), and (TMA) enable precise measurement of thermal events such as phase changes, moisture loss, and structural transitions, which directly influence texture, , and sensory attributes. These methods help optimize processes like , emulsification, and while ensuring with standards by detecting or early. TGA is widely employed to quantify and volatile content in matrices, providing insights into and product stability. For instance, in cereals, TGA reveals loss of approximately 5-10% when heated to 105°C, distinguishing free (evaporating below 100°C) from bound (releasing at higher temperatures due to interactions with proteins or starches). This differentiation aids in predicting microbial growth risks and formulating low- products like snacks or flours. Additionally, TGA with headspace analysis detects volatile compounds indicative of spoilage, such as aldehydes from oxidation, enhancing shelf-life evaluations in perishable items. DSC excels in characterizing phase transitions in fats and oils, which are essential for and in products like spreads and . In , DSC identifies polymorphs through distinct melting profiles, with the stable β-form exhibiting an endothermic peak at around 34°C, guiding tempering processes to achieve smooth and prevent fat bloom. Oxidative rancidity is monitored via exothermic peaks during controlled heating, signaling formation and degradation in oils, as seen in studies of fats where oxidation onset occurs above 150°C under oxygen exposure. These analyses ensure product consistency and extend usability in lipid-rich foods. Starch gelatinization, a key process in cooking and baking, is quantified using DSC to measure endothermic transitions where starch granules absorb water and swell. In wheat starch, this occurs as a broad endotherm between 60-70°C, with enthalpy changes reflecting granule integrity and processing history. Post-cooking retrogradation, involving starch recrystallization, shows increased enthalpy in DSC scans after storage, helping food technologists adjust cooling rates to minimize staling in breads and pastries. This thermal profiling optimizes energy inputs in extrusion and supports formulation of gluten-free alternatives. Protein denaturation in foods affects structural integrity and sensory qualities, and both DSC and TMA provide complementary data on these events. DSC detects endothermic peaks for protein unfolding, while TMA measures dimensional changes like shrinkage in meat collagen at around 60°C, correlating with tenderness and juiciness loss during cooking. In processed meats, these techniques assess thermal stability to prevent excessive toughening. For shelf-life assessment, TGA complements by tracking volatile release from denatured proteins, indicating Maillard reactions or hydrolysis in dairy and meat products. Specific applications highlight thermal analysis in refining food properties. In dairy products, DSC monitors fat crystallization to improve spreadability in margarines, where polymorphic transitions below 20°C influence solidity at refrigeration temperatures. For baking, DMA evaluates dough rheology under oscillatory heating, revealing viscoelastic changes during proofing and gelatinization that predict crumb structure and volume in final loaves. These targeted uses underscore thermal analysis as a cornerstone for innovation in food formulation and quality assurance.

Printed circuit boards

Thermal analysis plays a crucial role in evaluating the reliability of printed circuit boards (PCBs) by assessing material integrity and performance under , particularly during assembly and operational cycling. Techniques such as (DSC), (TGA), (TMA), and (DMA) are employed to characterize solder joints, laminates, and overall structural stability, helping to predict failure modes like cracking or in electronic assemblies. In solder joint analysis, is widely used to determine the melting range of alloys, ensuring compatibility with processes. For traditional Sn-Pb eutectic s, the is approximately 183°C, while lead-free Sn-Ag-Cu () alloys exhibit a higher around 217°C, necessitating adjustments in peak reflow temperatures to achieve uniform wetting and void-free joints. Reflow profile optimization via involves simulating heating ramps to balance flux activation, solder , and cooling rates, minimizing formation and improving joint . For laminate stability in PCBs, such as epoxy-based materials, quantifies resin decomposition, revealing significant mass loss beginning around 300°C due to epoxy volatilization, which informs maximum processing temperatures to prevent charring during or rework. Complementarily, TMA measures the temperature (T_g), typically ranging from 130°C to 180°C for standard to high-T_g variants, marking the onset of increased and potential dimensional instability under heat. Under thermal cycling, which simulates operational temperature fluctuations, DMA assesses warpage and modulus degradation in copper-clad layers by tracking storage modulus and tan δ shifts, often showing a modulus drop above T_g that exacerbates bowing in multilayer boards. Coefficient of thermal expansion (CTE) mismatch between copper (17 ppm/°C) and epoxy resin (50-70 ppm/°C in the z-axis) induces shear stresses, leading to delamination at interfaces during repeated cycles from -40°C to 125°C. Reliability metrics for PCBs incorporate activation energies derived from Arrhenius models applied to accelerated thermal cycling tests, where failure rates of solder joints follow exponential temperature dependence with typical activation energies of 0.5-0.7 eV for and mechanisms, enabling lifetime predictions under use conditions. Standards like IPC-TM-650 outline tests, including 2.6.7 methods for evaluating PTH integrity and 2.4.24 for T_g via TMA, ensuring compliance with reliability thresholds for automotive and . The 2006 RoHS directive accelerated the transition to lead-free solders in PCBs, prompting thermal analysis to validate higher reflow profiles and mitigate risks like tin whisker growth, with confirming SAC alloy stability post-implementation. In humid environments, detects hygroscopic swelling by measuring moisture-induced weight gain in epoxy laminates, which can amplify mismatches and promote popcorning defects during reflow, as swelling strains reach 0.3-0.5% at 85% relative humidity.

Pharmaceuticals

Thermal analysis techniques, particularly (DSC) and (TGA), play a crucial role in pharmaceutical development by characterizing active pharmaceutical ingredients (), formulations, and their stability under various conditions. These methods enable the detection of transitions, decomposition profiles, and interactions that influence drug efficacy, , and shelf-life, aligning with regulatory requirements for . In polymorphism screening, is widely employed to identify and differentiate polymorphic forms of through distinct melting endotherms or peaks. For instance, exhibits multiple polymorphs, with Form I melting at approximately 193°C and Form II at around 189°C, as observed in scans; these differences are critical for assessing and issues, as metastable forms like Form II can convert to the stable Form I upon heating between 140–160°C. Similarly, versus transitions are detected by endothermic peaks corresponding to , aiding in the selection of stable crystal forms during early . Modulated further quantifies amorphous content in crystalline , which impacts rates and . Stability testing utilizes to monitor mass loss events, such as or onset, providing insights into thermal degradation kinetics under accelerated conditions. For high-purity (>99%), typically shows minimal residue (<1% mass loss up to temperatures), indicating low levels; this supports with ICH Q1A(R2) guidelines for accelerated aging studies at 40°C/75% RH to predict long-term shelf-life. for degradation can be calculated from data using Arrhenius models, helping forecast in formulations exposed to heat during or . Excipient compatibility is evaluated through DSC mixing studies, where binary mixtures of API and excipients are scanned for shifts in melting peaks, new exothermic events, or eutectic formations signaling interactions. For example, drug-polymer mixtures may show a lowered eutectic melting point, indicating potential instability in solid dispersions; absence of such changes confirms compatibility for tablet formulations. These studies accelerate preformulation screening, reducing the risk of chemical or physical incompatibilities during scale-up. Dissolution insights are gained via thermomechanical analysis (TMA), which measures dimensional changes like tablet swelling or in simulated fluids, correlating with disintegration and drug release profiles. Isothermal TMA at 37°C reveals swelling , where initial expansion rates predict dissolution behavior for immediate-release tablets, ensuring consistent . Notable examples include the use of (DTA) and in biopharmaceuticals, such as insulin formulations, to assess stability and guide cold-chain requirements; reveals denaturation peaks around 70–80°C in hydrated insulin, emphasizing the need for storage below 8°C to maintain bioactivity. Since the , profiling has surged in biopharma with the rise of biologics, integrating for higher-order structure analysis under ICH Q6B guidelines.

Limitations and considerations

Sources of error

Thermal analysis techniques, such as (DSC), (TGA), and (DMA), are susceptible to various sources of error that can compromise data accuracy and reproducibility. These errors arise from instrumental, sample-related, environmental, , and quantification factors, each requiring specific mitigation strategies to ensure reliable results. Instrumental factors represent a primary source of error, including baseline drift caused by sensor aging or in the . This drift can introduce systematic offsets in heat flow or mass measurements, leading to inaccurate peak areas or temperatures. To correct for this, performing empty pan or reference runs prior to sample analysis allows subtraction of the baseline, restoring . Another common issue is temperature lag, particularly in larger samples where delays result in shifted transition temperatures. Minimizing sample size to less than 10 mg reduces this lag, ensuring the sample closely follows the programmed profile. Sample-related issues often stem from inhomogeneity, which causes irreproducible peaks or mass loss events due to uneven or . For instance, in powdered samples, larger particles may heat unevenly, broadening transitions; sieving to achieve uniform particle sizes below 100 μm mitigates this by promoting homogeneity. Oxidation artifacts also pose risks in reactive atmospheres, where unintended reactions alter sample mass or , mimicking . Purging the system with inert gases like or prevents such artifacts, maintaining the sample's integrity during analysis. Environmental influences can further distort results, particularly humidity effects on hygroscopic samples, which absorb and shift or melting points. Storing and preparing samples in a dry box or minimizes water uptake, preserving the material's thermal behavior. Vibrations from laboratory equipment or building activity impact sensitive balances in or , causing noise in mass or modulus data. Isolating the on vibration-dampening platforms or conducting analyses in controlled environments reduces this . Data processing errors frequently occur during interpretation, such as misintegration of overlapping peaks, which underestimates or overestimates transition enthalpies. Deconvolution software, applying Gaussian or fitting models, separates these peaks for accurate quantification. Scan rate sensitivity also introduces errors, as faster rates may broaden peaks or miss subtle events due to kinetic limitations. Validating results by comparing from multiple scan rates (e.g., 5–20 °C/min) confirms rate-independent behavior. Technique-specific calibrations, such as using standards in , briefly address calibration drift but are essential for ongoing accuracy. Quantification limits highlight inherent sensitivities, with typically detecting changes below 0.1 J/g, beyond which weak transitions become indistinguishable from noise. drift over time exacerbates this, necessitating periodic verification with certified standards like ( 156.60 °C, ΔH = 28.58 J/g) as certified by NIST SRM 2232a (2024). Adhering to these mitigation strategies enhances the reliability of thermal analysis data across applications.

Complementary methods

Thermal analysis techniques are often combined with other analytical methods to provide a more comprehensive understanding of material behavior under , enabling the identification of chemical compositions, structural changes, and kinetic mechanisms that standalone thermal methods cannot fully resolve. These hyphenated or complementary approaches enhance data interpretation by correlating thermal events with spectroscopic, microscopic, or structural information, leading to improved accuracy in material across various fields. Hyphenated thermal methods integrate thermal analysis directly with spectroscopic tools for real-time analysis of evolved gases and reactions. For instance, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) identifies gaseous decomposition products, such as carbon dioxide released from carbonate minerals during thermal decomposition, allowing precise determination of reaction pathways and stoichiometry. Similarly, differential scanning calorimetry linked to mass spectrometry (DSC-MS) detects volatile fragments evolved from polymers during heating, facilitating the study of degradation mechanisms and thermal stability without requiring sample isolation. Spectroscopic pairings extend this synergy by providing molecular-level insights into thermal processes. Evolved gas analysis combined with gas chromatography-mass spectrometry (EGA-GC-MS) separates and identifies complex decomposition products from thermal events, offering detailed profiles of volatile organics in materials like pharmaceuticals or composites. Additionally, integrated with enables in-situ monitoring of phase transitions, such as crystallization or polymorphism in polymers, by capturing vibrational spectra that correlate directly with endothermic or exothermic peaks observed in the calorimetric data. Microscopic complements allow visual correlation of thermal events, bridging macroscopic thermal responses with microstructural observations. Hot-stage microscopy paired with differential thermal analysis (HSM-DTA) visualizes dynamic processes like bubble formation in melts or in ceramics, synchronizing optical images with thermal curves to elucidate mechanisms such as or morphological evolution during heating. This approach is particularly valuable for opaque samples where indirect thermal data alone may overlook spatial heterogeneities. Structural techniques complement thermal analysis by characterizing pre- and post-thermal states at the atomic level. applied to residues after reveals crystalline s formed during , such as structures in metal powders, providing evidence of completeness and purity. In pharmaceuticals, (NMR) spectroscopy compares molecular structures before and after thermal treatment, identifying changes like or degradation products that influence drug stability and . Modeling integration further enhances thermal analysis by incorporating experimental data into predictive frameworks. Finite element simulations utilize thermal data from techniques like TMA or to model stress distributions and predict material performance under thermal loads, such as in composites where temperature-induced deformations are critical. Kinetic software like Advanced Kinetic Tools and Software (AKTS) validates multi-method data by fitting thermal curves from , , and evolved gas analysis to derive activation energies and reaction orders, ensuring robust predictions of long-term thermal behavior.

References

  1. [1]
    Thermal analysis and calorimetry: two tightly linked groups of ...
    “Thermal analysis (TA) refers to a group of techniques in which a property of a sample is moni- tored against time or temperature while the tempera- ture of ...
  2. [2]
    [PDF] The State-of-the-art of thermal analysis
    ... thermal methods are used to study the behavior of glass during heating and devitrifica- tion. Thermal analysis techniques are used by steel industries for.
  3. [3]
    The Status and Progress of Thermal Analysis Kinetics - IOP Science
    Differential thermal analysis is a method of measuring the relationship between temperature difference and temperature (or time) of a sample and a reference ...
  4. [4]
    2.4 Specific Heats - MIT
    We will call the specific heat at constant pressure $ C_p$ , and that at constant volume $ C_v$ , or $ c_p$ and $ c_v$ per unit mass.<|control11|><|separator|>
  5. [5]
    Thermal Analysis | SpringerLink
    Feb 16, 2010 · Changes in structure (transitions) are either endothermic, where the sample absorbs additional energy (heat), or exothermic, where heat is ...
  6. [6]
    Thermal events | SpringerLink
    When a single pure solid substance, A, is heated in an inert atmosphere, the resultant increase in molecular, atomic or ionic motion may lead to changes in ...
  7. [7]
    Thermal conductivity through the 19th century - Physics Today
    Aug 1, 2010 · With the invention of the calorimeter in the 1780s by Antoine Lavoisier (1743-94) and Pierre Simon Laplace (1749-1827), the latent heat of ...
  8. [8]
    Energy homeostasis from Lavoisier to control theory - PMC
    Jul 24, 2023 · Physiological energetics was founded by Lavoisier, who in the late eighteenth century invented direct and indirect calorimetry and discovered ...Missing: 19th | Show results with:19th
  9. [9]
    [PDF] DIFFERENTIAL THERMAL ANALYSIS
    The measurement of thermal changes in soils dates back to Le Chatelier, who, in 1887, published thermal data on halloysite, allo- phane, kaolin, pj'rophyllite, ...
  10. [10]
    [PDF] Thermal Analysis in Practice Tips and Hints
    Thermal analysis is one of the oldest analytical techniques. Throughout history, people have used simple heat tests to determine whether materials were ...
  11. [11]
    Origin and development of differential thermal analysis - ScienceDirect
    The thermochemical nature of the events occurring during the heating or cooling regime is recognizable from Le Chatelier's temperature-time experiments.
  12. [12]
    What is Thermogravimetric Analysis? - TA Instruments
    Nov 4, 2024 · A testament to the march of scientific inquiry, thermogravimetry emerged through the integration of three individual inventions in the 19th ...
  13. [13]
    (PDF) Thermogravimetric Analysis of Polymers - ResearchGate
    Jan 16, 2019 · TGA analysis also shows delayed degradation in PMB, starting around 370-400 °C, while virgin bitumen begins degrading near 300-320 °C. ...
  14. [14]
    2.8: Thermal Analysis - Chemistry LibreTexts
    Aug 28, 2022 · DSC was developed in 1962 by Perkin-Elmer employees Emmett Watson and Michael O'Neill and was introduced at the Pittsburgh Conference on ...
  15. [15]
    ICTAC - International Confederation for Thermal Analysis and ...
    The aim of ICTAC is to promote international understanding and cooperation in thermal analysis. and calorimetry through the organization of international ...
  16. [16]
    (PDF) ICTAC nomenclature of thermal analysis (IUPAC ...
    3 Definition of the field of thermal analysis. Thermal analysis (TA) is the study of the relationship between a sample property and its temperature as the.
  17. [17]
    Hyphenation - TA Instruments
    Zitomer1 was the first to report the hyphenation of a MS to a thermobalance in 1968, while Kiss2 reported the same for an FTIR and thermobalance in 1969. (For a ...
  18. [18]
    [PDF] oldDSC.pdf - TA Instruments
    TA Instruments' QSeries DSCs are fifth-generation products, including the Q1000, Q100, Q10, and Q10P, with models like the Q1000 being research-grade.
  19. [19]
    (PDF) Temperature Calibration of Differential Scanning Calorimeters ...
    Aug 5, 2025 · 3. Standard Practice for Temperature Calibration of Differential Scanning Calorimeters and Differential. Thermal Analyzers, ASTM E967-92. 4 ...
  20. [20]
    Thermogravimetric Analysis (TGA) ASTM E1131, ISO 11358 - Intertek
    Thermogravimetric (TGA) analysis provides determination of endotherms, exotherms, weight loss on heating, cooling, and more.
  21. [21]
    Standards for thermal analysis (ISO, ASTM and DIN) - Linseis
    Find out more about DIN, ISO and ASTM standards for thermal analysis at Linseis. Precision and compliance for your measurement processes.Missing: 1990s | Show results with:1990s<|control11|><|separator|>
  22. [22]
    A Differential Scanning Calorimeter for Quantitative Differential ...
    A Differential Scanning Calorimeter for Quantitative Differential Thermal Analysis. Click to copy article linkArticle link copied! E. S. Watson ...Missing: original | Show results with:original
  23. [23]
    Differential Scanning Calorimetry Techniques: Applications in ...
    DSC is a thermal analysis apparatus measuring how physical properties of a sample change, along with temperature against time.
  24. [24]
    [PDF] THE CASE FOR A GENERIC DEFINITION OF DIFFERENTIAL ...
    As discussed above, Differential Scanning Calorimeters operate on one of two principles—differential temperature measurement and temperature servo measurements.Missing: seminal | Show results with:seminal
  25. [25]
    Differential Scanning Calorimetry (DSC) | METTLER TOLEDO
    Differential scanning calorimeters (DSC) are scientific instruments used in thermal analysis to measure the energy absorbed or released by a sample as it is ...Products · Benefits of Our DSC · Download Our DocumentsMissing: seminal | Show results with:seminal
  26. [26]
    Measurement of Specific Heat Functions by Differential Scanning ...
    Measurement of Specific Heat Functions by Differential Scanning Calorimetry. O'Neill, M. J.. Abstract. Publication: Analytical Chemistry.
  27. [27]
    [PDF] DSC purity - Mettler Toledo
    The DSC purity analysis is based on the Van't Hoff law of melting point depression of eutectic systems. For such substances, purities between 90 and 100 mol ...
  28. [28]
    [PDF] Thermogravimetric Analysis (TGA) Theory and Applications
    TGA measures weight/mass change and the rate of weight change as a function of temperature, time and atmosphere.
  29. [29]
    [PDF] decomposition kinetics using TGA, TA-075 - TA Instruments
    Hence, the activation energy can be determined directly by plotting 1n (1/1-α) versus 1/T, assuming a reaction order of one (a reasonable assumption for many ...
  30. [30]
    [PDF] Evolved Gas Analysis: Introduction to TGA/MS - TA Instruments
    TGA/MS is powerful tandem and excellent addition to the analytical chemist's tools. •High quality data is easy to obtain. Powerful software makes data reduction ...
  31. [31]
    3: Differential Thermal Analysis - Chemistry LibreTexts
    Oct 30, 2025 · In DTA, difference in temperature between the sample and an inert reference (∆T) is measured as the sample and the reference are heated or ...
  32. [32]
    [PDF] Thermal Analysis Techniques Differential Thermal Analysis (DTA)
    Differential Thermal Analysis (DTA). Introduction. DTA involves heating or cooling a test sample and an inert reference under identical conditions, while ...
  33. [33]
    [PDF] Differential Thermal Analysis: An Essential Technique for Material ...
    The principle of DTA is based on the measurement of the difference in temperature between a sample and a reference material as they are subjected to controlled ...<|control11|><|separator|>
  34. [34]
    Differential Thermal Analysis - an overview | ScienceDirect Topics
    Differential thermal analysis (DTA) is defined as a technique that measures the temperature and phase changes of a substance during heating, ...
  35. [35]
    [PDF] Dynamic Mechanical Analysis Basic Theory & Applications Training ...
    Torsion (rotational) and DMA (axial) geometries allow solid samples to be characterized in a temperature controlled environment. E = 2G(1 + ν) ν : Poisson's ...
  36. [36]
    Basics of Dynamic Mechanical Analysis (DMA) - Anton Paar Wiki
    Dynamic Mechanical Analysis (DMA) is a characterization method that can be used to study the behavior of materials under various conditions.
  37. [37]
    Mechanical Properties of Polymers and Composites, Second Edition
    This text, now in its second edition, offers an up-to-date, expanded treatment of the behaviour of polymers with regard to material variables and test and ...Missing: DMA | Show results with:DMA
  38. [38]
    Principle of Dynamic Mechanical Analysis (DMA) - Hitachi High-Tech
    DMA is used for measurement of various types of polymer materials using different deformation modes. There are tension, compression, dual cantilever bending, 3 ...
  39. [39]
    thermomechanical analysis (12321) - IUPAC
    thermomechanical analysis (n.) ... A technique where the deformation of the sample is measured under constant load. Source: PAC, 2014, 86, 545. (ICTAC ...Missing: definition | Show results with:definition<|separator|>
  40. [40]
    [PDF] LA-UR-24-22990 - OSTI.GOV
    Apr 2, 2024 · 1. Among the thermal characterization techniques available today, thermomechanical analysis (TMA) has its own distinct advantages.
  41. [41]
    [PDF] THERMOMECHANICAL ANALYSIS - TA Instruments
    Thermomechanical analysis (TMA) measures sample dimensional changes under controlled temperature, time, force, and atmosphere.
  42. [42]
    [PDF] exploring the sensitivity of thermal analysis techniques to the glass ...
    Five thermal analysis techniques (DSC, modulated DSC™, TMA, DMA, and DEA) are used to characterize the glass transition temperature (Tg) for amorphous polymers.Missing: review | Show results with:review
  43. [43]
    [PDF] Measurement of Glass Transition Temperatures by Dynamic ...
    This note will detail the use of dynamic mechanical analysis (DMA) and rheology to characterize the glass transition of a polymeric material. GLASS TRANSITIONS.Missing: review | Show results with:review
  44. [44]
    The Scissors Effect in Action: The Fox-Flory Relationship between ...
    Oct 28, 2020 · As known, according to the Fox–Flory equation [66], the Tg of homopolymers is inversely proportional to their number average molecular weight: ...
  45. [45]
    [PDF] Modulated DSC Paper #6 Measurement of Initial Crystallinity in ...
    Differential Scanning Calorimetry (DSC) has been used to measure the heat of crystalline melting (J/g) in polymers for over 40 years and is the most widely used.
  46. [46]
    [PDF] Application News AD-0091 - Shimadzu
    is determined from the following equation[4]:. % Crystallinity = (∆Hm /∆Hm0) x 100% where. ∆Hm0: heat of melting for 100% crystalline PET which is 144.664 ...
  47. [47]
    Thermal Stability of Nanosilica-Modified Poly(vinyl chloride) - PMC
    The dehydrochlorination takes place at the beginning of degradation when hydrogen chloride, unfastened from the PVC chain, acts as a catalyst and accelerates ...
  48. [48]
    Thermal degradation of polyvinyl chloride in the presence of lead ...
    Aug 1, 2024 · An inhibiting effect of PbO on the thermal degradation of PVC was observed; the onset PVC de-hydrochlorination temperature increased from 273 to 293 °C.
  49. [49]
    [PDF] A Review of DSC Kinetics Methods - TA Instruments
    DSC kinetics methods include Borchardt and Daniels, ASTM E-698 Thermal Stability, and Isothermal Kinetics, each calculating kinetic parameters.
  50. [50]
    [PDF] Characterization of Polymers by TMA - Thermal Support
    The TMA results show that the. LDPE sample undergoes a small amount of expansion between 40 and the melting temperature. At approximately 100 C, the sample.
  51. [51]
    Effect of Vulcanization System on Damping Properties of Natural ...
    Dec 21, 2022 · The aim of the current work is to characterize the dynamic mechanical response by DMA of three rubber formulations prepared with different ...<|separator|>
  52. [52]
    [PDF] DTA and Heat-flux DSC Measurements of Alloy Melting and Freezing
    ASTM E968, "Standard Practice for Heat Flow Calibration of DSC," uses sapphire as heat capacity standard. The method is described in section 2.4.4. ASTM ...
  53. [53]
    B-TA1014 - DSC measurement of binary alloys - Rigaku
    A heterogeneous alloy is composed of two or more phases. Here, we use the DSC method to determine the eutectic temperature and to characterize binary alloys.
  54. [54]
    Detection of the α‐γ Iron Phase Transformation by Differential ...
    This method is applied to the α‐γ transformation of iron at various pressures up to 100 000 atm. This transformation temperature was found to drop continuously ...
  55. [55]
    High-Temperature Oxidation Behavior of Fe–10Cr Steel under ... - NIH
    Jun 22, 2021 · During the oxidation process, the electronic balance attached to the TGA recorded the mass change of the specimen in real time. After the ...
  56. [56]
    A Study of the Thermal Properties of a Binary Eutectic Alloy of Tin ...
    Dec 22, 2011 · Overall, the DSC provided a method of analysis for the determination of a binary alloy composition of Sn/Pb and the construction of a simple ...
  57. [57]
    [PDF] A New DTA Approach for Verifying Precipitate Solvus in Inconel ...
    Examples in superalloys are incipient melting and dissolution of precipitate phases. Ideally the heat capacities of both sample and reference are constant, and ...
  58. [58]
    [PDF] Dynamic Mechanical Analysis of Printed Circuit Board Laminates
    DMA response of a phenolic-cured laminate PCB for power applications: storage modulus; loss modulus; tangent delta. Initial heating cycle curves are ...Missing: warpage | Show results with:warpage
  59. [59]
    [PDF] Printed Circuit Board Inspection and Quality Control – PCB Failure ...
    Fiber/resin interface delamination occurs as a result of stresses generated under thermal cycling due to a large CTE mismatch between the glass fiber and the ...
  60. [60]
    Kinetics of intermetallic phase formation at the interface of Sn–Ag ...
    ... melting point of these alloys (217 °C). The melting point of a traditional Sn–Pb solder is only 183 °C. In order to decrease the melting point of Sn–Ag–Cu ...
  61. [61]
    Properties and Microstructures of Sn‐Ag‐Cu‐X Lead‐Free Solder ...
    Feb 18, 2015 · As we all know, the eutectic SnPb has a melting point of 183°C, while the SnAgCu solder melting point is 217°C, 34°C higher than that of the ...
  62. [62]
    [PDF] LOW TEMPERATURE SOLDERING - Circuit Insight
    DSC analysis showed that Bi content should be equal or higher than 40 wt.% for enabling reflow profiles with peak temperature lower than 200oC [14-15]. Cross-.
  63. [63]
    Determination of the thermal endurance of PCB FR4 epoxy ...
    Sep 27, 2025 · Thermogravimetric analyses revealed that above 300 °C intensive thermal degradation occurs on FR4 materials (with 30% mass change), followed ...
  64. [64]
    High Tg PCBs - Sierra Circuits
    A PCB is considered a high Tg board if its Tg is higher than 180 °C. Standard FR-4 boards have a Tg of around 130 to 150 °C.Missing: TMA | Show results with:TMA
  65. [65]
    Investigation of Impacts on Printed Circuit Board Laminated ... - NIH
    Warpage is an effect occurring when the PCB is exposed to thermal stress. ... Copper Clad Laminates Used in Waste Printed Circuit Boards. J. Air Waste ...
  66. [66]
    [PDF] Enabling More than Moore: Accelerated Reliability Testing and Risk ...
    Predicting solder joint fatigue failure under thermal cycling stress has been one of the challenging problems for microelectronic packaging and assembly. Early ...
  67. [67]
    where does activation energy of 0.7eV come from? - No MTBF
    Aug 1, 2012 · Short discussion about the origin and use of the 0.7eV activation energy for the Arrhenius rate equation and reliability engineering.
  68. [68]
    [PDF] IPC-TM-650 TEST METHODS MANUAL
    Acceptance testing and quality conformance testing as described in IPC-6010 series printed board performance specifications. IPC-TM-650. Number. 2.6.7.2.Missing: analysis | Show results with:analysis
  69. [69]
    [PDF] Impact of Lead Contamination on Reliability of Lead Free Alloys
    Abstract. Meeting the RoHS directive will require the transition from the historical tin-lead based system of materials to one that does not contain lead.
  70. [70]
    [PDF] Impact of Moisture Content on Printed Circuit Board Laminate ...
    Apr 2, 2024 · Firstly, moisture causes swelling in PCB laminate above 100ºC, and increases the z-axis ... increase in the duration when exposed to thermal ...
  71. [71]
  72. [72]
  73. [73]
    Polymorphic Phase Transitions in Carbamazepine and 10,11 ... - NIH
    Using DSC, it has been shown that upon heating at 20 °C min−1 CBZ II undergoes a solid–solid phase transition to form I between 140 and 160 °C, and form III ...
  74. [74]
    Differential scanning calorimetry: applications in drug development
    Differential scanning calorimetry can be a used for rapid screening of excipients in drug–excipient compatibility studies. There are several advantages in using ...
  75. [75]
    (PDF) Evaluating drug delivery of solid dose tablets by isothermal ...
    Aug 5, 2025 · TMA can be used to measure the swelling, shrinkage, or disintegration of a formulated tablet in a specified fluid. The focus of this study is to ...
  76. [76]
    MD and DSC study of bioactive structural stability of insulin in ...
    Mar 1, 2019 · Moreover, the micro-DSC experimental results prove that the thermal stability of insulin in hydrated [C2mim][OAC] also support the results of MD ...