Fact-checked by Grok 2 weeks ago

Sweep generator

A sweep generator is an electronic test instrument that produces a sinusoidal output signal whose varies smoothly and continuously over a specified band, often at an audio repetition rate of around 20 sweeps per second, to facilitate the analysis of circuit responses. This variation is typically achieved through , where a low-frequency modulating voltage from a frequency sweeper alters the of the oscillator's tank circuit, either electronically via variable or mechanically with a motor-driven component. Key components include the frequency sweeper for generating the modulating voltage, the oscillator for producing the swept sinusoidal , a marker generator to insert reference signals identifying specific frequencies within the sweep range, and an automatic level control circuit to maintain consistent output despite frequency or load changes. In modern implementations, sweep generators often integrate with function generators or arbitrary waveform generators (AWGs), employing digital techniques such as direct digital synthesis () to enable precise control over sweep parameters like start and stop frequencies, sweep duration (from microseconds to seconds), and modes (linear or logarithmic). These devices support configurable directions (up or down sweeps) and trigger options, allowing the output to idle at a baseline carrier frequency or DC level until activated. Sweep generators are essential in testing, particularly for evaluating the of filters, amplifiers, and RF circuits by displaying results on a cathode ray (CRO) or , where the sweep synchronizes horizontal deflection. They find applications in , prototyping, radio systems, and alignment procedures for devices like televisions and transceivers, speeding up the identification of characteristics and resonances.

Fundamentals

Definition and Purpose

A sweep generator is a piece of similar to a , designed to produce electrical waveforms—typically sinusoidal—where the frequency varies linearly or logarithmically over time while maintaining a constant unless otherwise specified. This variation, known as sweeping, allows the device to output signals that systematically traverse a defined frequency band, distinguishing it from static signal generators that produce fixed-frequency outputs. The primary purpose of a sweep generator is to characterize frequency-dependent behaviors in electronic circuits and systems, such as measuring , identifying frequencies, and assessing in components like filters, amplifiers, and antennas. By sweeping the input signal across a range, it enables engineers to observe how a device's response changes with , facilitating the identification of performance limits and anomalies without manual retuning. This makes it an essential tool for , , and diagnostic testing in (RF), audio, and general applications. Key characteristics of a sweep generator include its sweep range, defined by start and stop frequencies (for example, 20 Hz to 20 kHz in audio testing), the sweep rate that controls the speed of frequency transition, and synchronization outputs such as start/stop markers or trigger signals to coordinate with measurement instruments like oscilloscopes. These features ensure precise control and repeatability in tests. For instance, a sweep generator can produce a signal—a rapid, continuous frequency sweep—for efficient response evaluation, allowing quick visualization of passbands and characteristics.

Operating Principles

A sweep generator produces a sweeping signal by modulating the (or sometimes ) of a carrier , typically a , using a control signal such as a ramp voltage applied to a (VCO). This causes the output to vary continuously over a specified range and duration, enabling the generation of swept sinusoidal signals for testing purposes. The VCO's is adjusted by the control voltage, which is often derived from a linear ramp generator for precise variation, while a may combine the VCO output with a fixed master oscillator to produce the final swept as the difference between the two. Sweep generators support both linear and logarithmic frequency variations to suit different testing needs. In a linear sweep, the frequency changes at a constant rate, given by the equation f(t) = f_0 + \frac{(f_1 - f_0)}{T} t, where f_0 is the start frequency, f_1 is the end frequency, t is time, and T is the sweep duration; this is equivalent to f(t) = f_\text{start} + k t with k = (f_1 - f_0)/T. Logarithmic sweeps, in contrast, vary frequency exponentially to provide proportional coverage across bandwidths, following f(t) = f_\text{start} \cdot e^{k t} (or equivalently f(t) = f_0 \left( \frac{f_1}{f_0} \right)^{t/T}), where k = \ln(f_1 / f_0)/T; this ensures more time is spent at lower frequencies, which is useful for octave-based . To facilitate alignment with measurement instruments like oscilloscopes, sweep generators include features such as outputs or . These provide timed at the start of the sweep or at specific within the range, allowing external devices to synchronize their displays or sampling to the varying signal. For instance, a can highlight a particular point during the sweep for precise . Amplitude control in sweep generators ensures a constant output level throughout the sweep to isolate frequency-dependent effects in the device under test, avoiding distortions from varying signal strength. This is achieved through (AGC) circuits or level adjustment mechanisms that maintain the with a flat response across the range.

Applications

Frequency Response Testing

Sweep generators are essential tools for evaluating the of electronic circuits, such as filters and , by applying a continuously varying input signal across a specified range to the device under test (DUT). This process allows engineers to observe how the circuit's output and change with , enabling the characterization of key performance parameters. In a typical setup, the sweep generator's output is connected directly to the input of the DUT, while the output of the DUT is fed into a measurement instrument like a , , or power meter to capture the response. A synchronization pulse from the sweep generator triggers the to align the frequency sweep with the measurement trace, ensuring accurate plotting of the response curve over time. This configuration facilitates the measurement of (expressed in decibels as 20 log₁₀ of the voltage ), phase shift, and levels across the frequency band. The primary benefits of using sweep generators in frequency response testing include the identification of passbands, where the circuit exhibits flat gain, and stopbands, where signals are significantly attenuated, as well as the determination of the quality factor (Q-factor) in resonant circuits. For instance, in testing filters, the sweep reveals frequencies at the -3 points, highlighting the and characteristics that define the filter's selectivity. Common frequency ranges for such testing extend into the RF domain, often up to several GHz for applications like antenna evaluation, where high precision is required to resolve responses without introducing errors. However, limitations arise if the sweep rate is too fast, potentially causing nonlinear distortions in the output signal that skew the measured response and reduce accuracy, particularly in high-Q or devices.

Audio and RF Analysis

In audio analysis, sweep generators produce signals spanning the human of 20 Hz to 20 kHz to evaluate , room acoustics, and harmonic distortion levels. These sweeps excite the system under test, allowing measurement of how speakers reproduce frequencies and how room reflections alter sound propagation, with logarithmic sine sweeps preferred for their ability to allocate equal time per , ensuring adequate at low frequencies where linear sweeps would spend disproportionately more time. For instance, a logarithmic sweep can identify frequency-dependent impedance variations in amplifiers by monitoring voltage and current responses during the sweep, revealing resonances or mismatches that affect power delivery. Harmonic distortion assessment benefits from the swept-sine , where the progression separates distortion products in time, enabling their from the linear without overlap. This method, robust against time-variant effects like room modes, uses inverse filtering to reconstruct the system's , providing clear spectra of even and odd up to high orders. Challenges include maintaining signal purity through sufficiently slow sweep rates—typically 10-60 seconds for full-range audio—to prevent harmonic responses from overlapping the , which could otherwise mask data. Logarithmic sweeps address wide coverage efficiently, avoiding the uneven resolution of linear alternatives in audio's multi-decade span. In RF analysis, sweep generators operate at higher frequencies from MHz to GHz to characterize components like , cables, and modulators, often integrated within vector network analyzers (VNAs) that generate swept stimuli to measure . For antenna tuning, the sweep assesses and voltage (VSWR) across bands, identifying optimal matching to minimize reflections and maximize . Cable loss evaluation involves sweeping to quantify and detect discontinuities, such as connectors causing frequency-dependent attenuation, essential for maintaining in transmission lines. Modulator testing uses sweeps to verify AM/FM symmetry and deviation, ensuring linear operation without spurious emissions. RF applications demand high signal purity to avoid distortion (IMD), where nonlinearities generate unwanted products that degrade accuracy; for example, second-order IMD can appear at -45 under moderate input power, necessitating low-power sweeps or high-linearity generators. VNAs mitigate this through to correct systematic errors like loss increasing with , while their closed-loop design synchronizes the sweep source with receivers for phase-coherent . Sweep generators pair with FFT analyzers for visualization of responses, transforming time-domain into spectra to highlight IMD or profiles during sweeps. Since the , sweep generators have been integral to broadcast equipment calibration, particularly for modulation testing, where they align (IF) stages by sweeping around carrier frequencies like 10.7 MHz to visualize discriminator output and ensure flat response across the 75 kHz deviation band. Early devices, such as marker-equipped sweepers, facilitated precise tuning of receivers by injecting swept signals and observing alignment curves on oscilloscopes, a practice standardized in radio service by mid-decade.

Types of Sweep Generators

Glide Sweep

A glide sweep, also known as a sweep, is a continuous type of sweep in which the signal's varies smoothly and continuously from a starting to an ending , typically following a logarithmic progression over a defined time period. This approach ensures uniform energy distribution across the range, making it suitable for broad-spectrum analysis without discrete interruptions. In its mechanism, a glide sweep is generated using a (VCO) whose is modulated by an shaped control voltage to achieve the desired logarithmic variation. This exponential control compensates for the inherent logarithmic relationship between control voltage and output in VCOs, enabling precise and smooth transitions ideal for time-compressed testing scenarios. Key advantages of glide sweeps include providing high resolution across wide bandwidths while significantly reducing overall test duration compared to stepped methods, as the continuous nature allows adjustable sweep lengths without sacrificing detail. The logarithmic progression is mathematically expressed as: f(t) = f_0 \cdot 10^{\left( \log_{10}(f_1 / f_0) \cdot t / T \right)} where f(t) is the instantaneous at time t, f_0 is the start , f_1 is the end , and T is the total sweep duration. Unique applications of glide sweeps encompass and characterization of filters, where the continuous coverage efficiently reveals response characteristics over extensive ranges. They are also prevalent in modern audio analyzers for evaluating , distortion, and phase in devices like loudspeakers and microphones. Despite these benefits, glide sweeps necessitate compensation techniques to address nonlinearities in frequency progression, such as those arising from VCO tuning curves or environmental factors, often requiring post-processing or . Additionally, precise generation, particularly in implementations, can be computing-intensive due to the need for high-resolution signal synthesis and .

Stepped Sweep

A stepped sweep generator produces signals that vary in frequency or amplitude in discrete, fixed increments, such as 1 kHz steps for frequency or specific level changes for amplitude, enabling targeted measurements at predefined points. The mechanism relies on digital counters or digital-to-analog converters (DACs) to generate precise step commands that control the oscillator, with a configurable dwell time at each step to ensure measurement stability and settling. This dwell time, typically ranging from 25 ns to several seconds, allows the system under test to stabilize before advancing to the next increment. Key advantages include the ability to pause at individual steps for in-depth analysis and its suitability for testing in analog-to-digital converters (ADCs) and digital-to-analog converters (DACs), where steps at fixed reveal and characteristics. The step follows the relation f_n = f_0 + n \cdot \Delta f, where f_0 is the starting , n is the step number, and \Delta f is the increment size. Stepped sweeps are commonly employed in production testing to verify compliance at specific frequencies, offering repeatable and precise control for quality assurance in RF and audio systems.

Time Sweep

A time sweep, in the context of sweep generators, involves applying a stationary input signal with fixed frequency and amplitude to a device under test while measuring the output response as a function of time to detect variations such as decay or gradual changes. This method differs from frequency-based sweeps by holding input parameters constant and focusing on temporal evolution to simulate and quantify long-term behavioral effects in electronic systems. The underlying mechanism relies on the sweep generator delivering a consistent signal, such as a or at unchanging level, synchronized with precise timing markers to enable detailed of the system's response over extended durations. This setup facilitates the isolation and capture of transient phenomena or steady-state stability, where the generator's output remains unaltered while measurement instruments, like oscilloscopes or analyzers, track deviations in , , or other parameters against elapsed time. Key applications of time sweeps include evaluating capacitor discharge characteristics, where a step or constant signal charges the , followed by observation of the exponential voltage decay across an . In amplifier testing, it assesses thermal drift by applying a fixed and monitoring output shifts due to self-heating or environmental variations over time. Additionally, time sweeps determine signal settling times in operational s, measuring the duration after a step input until the output stabilizes within a specified error band. A central metric in such analyses is the time constant \tau, which characterizes the rate of exponential decay in responses like capacitor discharge, given by the equation V(t) = V_0 e^{-t / \tau} where V(t) is the voltage at time t, V_0 is the initial voltage, and \tau = RC for a resistive-capacitive circuit. Despite its utility for dynamic and stability assessments, the time sweep is less commonly employed for frequency-domain characterization, as it prioritizes temporal dynamics over spectral analysis, and demands exceptionally stable reference signals to minimize measurement artifacts in prolonged tests.

Table Sweep

A table sweep is a specialized form of sweep generation that follows a predefined table of - pairs, enabling the creation of custom, non-linear signal profiles rather than uniform linear or logarithmic progressions. In operation, the mechanism relies on stored lookup tables in systems, where pairs of and level values are loaded into device and stepped through sequentially; analog implementations may use switched attenuators to select levels corresponding to each point, with optional between table entries for smoother transitions in some modern designs. This approach offers significant flexibility for complex testing scenarios, such as simulating real-world signals with non-monotonic responses or nonlinear device behaviors, where standard sweeps would be inadequate. Table sweeps are rarely employed due to the added setup of defining and loading tables, but they find use in advanced simulations like environmental testing with varying profiles or audio analysis requiring specific spectra, such as emulating voice or music patterns via a of up to 100 points for irregular RF interference replication.

Implementation Methods

Analog Circuits

Analog sweep generators rely on hardware circuits to produce linearly varying signals, typically for in testing applications. These implementations use continuous-time components to generate a control voltage that modulates an oscillator's output frequency over a specified range. The core components include a ramp generator, often realized as an using operational amplifiers to produce a linear voltage sweep; a (VCO) that translates the ramp into a frequency-varying output; and buffer amplifiers to isolate stages and maintain without loading the generator. In a typical setup, the ramp generator employs a constant-current source to charge a , yielding a sawtooth that drives the VCO via varactor diodes or similar tuning elements, while buffers such as or MMIC amplifiers ensure low-distortion output delivery. Common topologies for the ramp generator include the bootstrap sweep circuit, which uses feedback to achieve linear ramps by maintaining a constant voltage across a charging , and the Miller sweep, employing an configuration for high-speed operation. In the bootstrap design, a differential pair with via a capacitor linearizes the capacitor charging process, allowing ramp amplitudes close to the supply voltage. The Miller topology, based on the in a , integrates input current to produce fast sweeps suitable for time-base applications. The ramp voltage in these constant-current charging schemes follows the equation V(t) = \frac{I}{C} t where I is the charging current, C is the capacitance, and t is time. These analog circuits offer simplicity and low cost for basic frequency ranges, with examples operating up to 180 MHz as in low-budget designs. However, they suffer from drift due to component tolerances, aging, and temperature variations, which degrade linearity over time. Additionally, analog designs exhibit poor performance across wide dynamic ranges owing to inherent nonlinearities and noise in passive elements.

Digital Techniques

Digital techniques for sweep generation leverage computational methods to produce precise, programmable signals, primarily through (DDS) and (FPGA)-based implementations. employs a phase accumulator, waveform lookup table, and (DAC) to generate frequency-agile outputs from a stable reference clock, enabling fine control over sweep parameters. In FPGA-based systems, programmable logic facilitates custom cores, allowing tailored sweep profiles for applications requiring high linearity, such as systems. The core process in DDS involves numerical computation of waveform samples: a phase accumulator increments the phase value at each clock cycle, addressing a sine lookup table to produce digital amplitude values, which are then converted to analog via a high-speed DAC. For frequency sweeps, the phase increment Δφ is dynamically adjusted to ramp the output frequency linearly or nonlinearly. This is governed by the phase accumulator equation: \phi(n) = \phi(n-1) + \Delta\phi \pmod{2^N} where \phi(n) is the phase at step n, \Delta\phi is the frequency-tuning word determining the output frequency as f_{out} = (\Delta\phi \cdot f_{clk}) / 2^N, N is the accumulator bit width, and f_{clk} is the clock frequency. FPGA implementations extend this by storing arbitrary waveform tables in on-chip memory, enabling complex, user-defined sweeps through direct hardware control of phase and amplitude profiles. Another common digital approach uses (PLL) synthesizers, where a is locked to a reference via a and loop filter, allowing frequency sweeps by varying the divider ratio or reference for precise control in RF applications up to several GHz. These methods offer significant advantages, including sub-hertz frequency resolution (e.g., 1 μHz with 48-bit tuning), phase-continuous transitions for low , and repeatability across sweeps without analog drift. ranges span from to GHz, supported by high-speed DACs operating up to 1 GSPS, with software programmability via interfaces like USB or GPIB for and . Enabled by advances in the that integrated phase accumulators and DACs, digital techniques have become standard in modern instruments, such as 's 33600A series waveform generators.

Historical Development

Early Innovations

Sweep generators originated during as essential components in systems for generating linear time-based waveforms to drive displays, enabling precise range measurement and target tracking. These early implementations relied on circuits, such as multivibrators and blocking oscillators, to produce sawtooth or exponential sweeps for high-speed range indications up to 2500 µs, corresponding to detection ranges of 240 miles. Innovations included mechanisms for improved (achieving less than 0.5% nonlinearity) and nonlinear hyperbolic sweeps to correct distortions in airborne presentations. In the post-war period of the late 1940s, sweep generators transitioned to commercial applications in radio and television servicing, with one of the earliest dedicated units being the Precision Apparatus Company E-400 Sweep Signal Generator introduced in 1948. This vacuum tube-based device provided swept signals across audio and low RF frequencies for aligning receivers and early sets, marking a shift from to testing. Key innovations involved variable frequency oscillators (VFOs) using inductance-capacitance (L-C) tuning to enable analog frequency sweeps, often limited initially to kHz ranges due to tube technology constraints. No single inventor is credited, but developments were influenced by engineers at companies like , building on broader evolution during the electronics boom. By the 1950s, sweep generators saw widespread adoption in time-bases for precise waveform display, exemplified by Tektronix's 535 series introduced in 1954, which incorporated triggered and delayed sweeps using amplifiers for enhanced accuracy in signal analysis. In radio servicing, they facilitated alignment of AM and receivers through continuous or stepped sweep modes, where discrete frequency steps allowed technicians to peak intermediate-frequency (IF) stages without full continuous . The 1955 Sweep and Marker Generators for Television and Radio by Robert G. Middleton documented these applications, emphasizing their role in troubleshooting TV horizontal and vertical circuits. This era's advancements were driven by the post-war surge in , with sweep generators becoming standard tools for efficient receiver alignment amid expanding AM/ and early markets, though performance remained constrained to lower frequencies until later refinements.

Modern Advancements

The introduction of Direct Digital Synthesis () technology in the revolutionized sweep generators by enabling precise, phase-continuous frequency glides with sub-Hertz resolution and low , overcoming limitations of analog varactor-based tuning. This advancement, building on the foundational 1971 proposal by Tierney, Rader, and , facilitated smoother sweeps for applications in RF testing and , with early commercial chips from companies like integrating DACs for direct waveform output. In the , the rise of software-defined radios (SDRs) extended sweep capabilities to GHz frequencies, allowing programmable, flexible signal generation through digital processing on platforms like the Ettus Research USRP series introduced in 2004. These systems replaced rigid hardware with software-configurable sweeps, supporting operations up to several GHz for communications and spectrum analysis, as demonstrated in GNU Radio-based implementations. Modern sweep generators have integrated seamlessly with automated test equipment (ATE), enhancing throughput in high-volume manufacturing by synchronizing sweeps with vector network analyzers and spectrum analyzers for rapid device characterization. Key milestones include the development of portable sweep units in the , such as Hewlett-Packard's modular 8360 series synthesizers, which offered compact, battery-operable designs up to 110 GHz for field testing. In the 2020s, vector sweep generators tailored for and mmWave analysis emerged, like Keysight's VXG family, providing up to 110 GHz coverage with 5 GHz modulation bandwidth for and phased-array validation. These advancements have significantly reduced the size and cost of sweep generators, enabling USB-powered units for consumer applications; for instance, the Analog Discovery series integrates sweep functions for response measurements in room acoustics tools. Instruments like Zurich Instruments' SHFSG provide cryogenic-compatible signal generation up to 8.5 GHz for qubit control in setups.

References

  1. [1]
    Block Diagram of Sweep Generator - EEEGUIDE.COM
    The frequency sweeper provides a variable modulating voltage which causes the capacitance of the master oscillator to vary.
  2. [2]
    Function Generators Explained - Electronics Notes
    Sweep function generator: A sweep function generator is simply one that can sweep its frequency. Typically the more versatile sweep function generators ...<|control11|><|separator|>
  3. [3]
    How to Simply Generate a Sweep - Tabor Electronics
    Tabor AWGs generate waveforms that “sweep” from a starting frequency to an ending frequency. This document will guide you through the definition process.
  4. [4]
    Sweep generator - Semantic Scholar
    A sweep generator is a piece of electronic test equipment similar to, and sometimes included on, a function generator which creates an electrical waveform ...
  5. [5]
    Sweep Frequency Generator: Function, Features & Applications
    Sep 1, 2024 · The basic function and features of a sweep frequency generator and its applications in electrical and telecommunication systems.
  6. [6]
    Sweep Signal Generators | GlobalSpec
    Sweep signal generators are electronic instruments designed to produce signals that vary in frequency over a predetermined range. These devices are capable of ...
  7. [7]
    Sweep generators – Knowledge and References - Taylor & Francis
    A sweep generator is a device that produces signals with a frequency that changes linearly and automatically within a specified range of values.
  8. [8]
    Sweep Frequency Generator - Block Diagram and its Workings
    Sweep frequency generators are primarily employed for measurement of responses of amplifiers, filters, and electrical components over various frequency bands.
  9. [9]
    Tips on using Frequency Sweep and List with your Function Generator
    Dec 12, 2018 · The specific range to sweep is the start and stop frequencies. The rate at which the generator will sweep the frequencies is set as the sweep ...
  10. [10]
    What is a Signal Generator? | Tektronix
    one that changes in frequency over a period of time. The ...
  11. [11]
    Let`s clear up some things about Sweeps - NTi Audio
    Glide Sweep A glide sweep (or chirp) is a continuous signal in which the frequency increases or decreases logarithmically with time. · Stepped Sweep In a stepped ...
  12. [12]
    How to Simply Generate a Chirp - Tabor Electronics
    The Tabor family of Arbitrary Waveform Generators (AWGs) generates waveforms that “sweep” from a starting frequency to an ending frequency, while supporting an ...
  13. [13]
    None
    Summary of each segment:
  14. [14]
    Chirp - Generate swept-frequency cosine (chirp) signal - Simulink
    In this example, the Chirp block outputs a bidirectional, linearly swept chirp signal, which is displayed by the Time Scope and the Spectrum Analyzer. You can ...
  15. [15]
    Sweep Frequency - an overview | ScienceDirect Topics
    There are two standard sweep methods, namely the logarithmic sweep and the linear sweep. In the logarithmic sweep, the excitation frequency f varies at a ...Missing: principles | Show results with:principles
  16. [16]
    Frequency Response Analysis of Amplifiers and Filters
    Frequency response shows how an amplifier or filter's output gain changes with input signal frequency, including magnitude and phase response.
  17. [17]
    Sweep Frequency Generator - CircuitsToday
    Oct 17, 2009 · A sweep frequency generator is a type of signal generator that is used to generate a sinusoidal output. Such an output will have its frequency ...
  18. [18]
    RF Amplifier and Filter Testing with Mini-Circuits Power Sensors
    Nov 6, 2024 · In this configuration, the frequency sweep mode of the RF signal generator can be utilized, or the frequency can be tuned manually. The RF power ...
  19. [19]
    Construction of a Low Budget 180 MHz RF Sweep Generator
    Sweep generators have a lot of uses in the design, prototyping, and troubleshooting of amplifiers, filters, and radio circuitry. They can greatly speed up ...
  20. [20]
    [PDF] Sweep Frequency Signal Generator Design Techniques - HP Archive
    Power to operate the transistor and the crystal bias circuit:y comes from a small self- contained battery used at low current drain. Battery life is essentially ...
  21. [21]
    [PDF] Simultaneous measurement of impulse response and distortion with ...
    The preferred technique is to employ a single, very long, logarithmic sine sweep: this produce a distortion-free linear response, well separated harmonic ...
  22. [22]
    Simultaneous Measurement of Impulse Response and Distortion ...
    The method is implemented with low-cost instrumentation; it is based on an exponentially-swept sine signal. It is applicable to loudspeakers and other audio ...
  23. [23]
    None
    ### Summary of Sweep Generators in RF Spectrum Analysis
  24. [24]
    What Are Vector Network Analyzers? | VNAs Explained - Tektronix
    A Vector Network Analyzer (VNA) is a test instrument that measures electrical network parameters, using a source and receivers to measure the response of a ...
  25. [25]
    [PDF] About FFT Spectrum Analyzers - thinkSRS.com
    The FFT spectrum analyzer samples the input signal, computes the magnitude of its sine and cosine components, and displays the spectrum of these measured ...
  26. [26]
    [PDF] sweep and marker - GENERATORS - World Radio History
    Types of attenuators. Stray capacitance. Residual leakage. Re- flections. The electronic attenuator. The waveguide attenuator. Attenuator calibration.
  27. [27]
    [PDF] Thermal Compensation of Analog Exponential Converters
    Mar 7, 2015 · The main goal of this work is to see what the limits are for creating a very accurate, and temperature stable exponential converter for VCOs.
  28. [28]
    chirp - Swept-frequency cosine - MATLAB - MathWorks
    y = chirp( t , f0 , t1 , f1 ) generates samples of a linear swept-frequency cosine signal at the time instances defined in array t . The instantaneous ...
  29. [29]
    [PDF] Measurement of frequency sweep nonlinearity using atomic ... - arXiv
    The nonlinearity can also be compensated by externally triggering time domain sampling or using post processed resampling algorithms [20,21].
  30. [30]
    [PDF] MG369xC Series Synthesized Signal Generators
    Stepped Sweep Start Range = MIN to MAX, where: MAX = MAX – 2 × minimum frequency step size. Analog Sweep Start Range = MIN to MAX, where; MAX = MAX – minimum ...
  31. [31]
    None
    Below is a merged summary of the "Stepped Sweep" feature from the HP 8360 B-Series User’s Guide and HP 8360B User Manual, consolidating all information from the provided segments into a comprehensive response. To retain maximum detail efficiently, I will use a table in CSV format for key attributes, followed by a narrative summary that integrates additional context and details not suitable for the table. The response avoids redundancy while ensuring all unique information is included.
  32. [32]
    [PDF] Experiment 8: Capacitance and the Oscilloscope
    Measurement of short RC​​ Drive the function generator with a square wave, and then analyze the wave on the scope as it moves through the RC circuit.
  33. [33]
    Temperature Drift in Resistors and Op-amps—Flicker Noise and ...
    Jul 15, 2022 · Learn about temperature drift in electronic circuits, namely in resistors and amplifiers. We'll also cover how the effect of flicker noise comes into play.
  34. [34]
    [PDF] MT-046: Op Amp Settling Time - Analog Devices
    Settling time is the time it takes an op amp's output to respond to a step input change and remain within a defined error band, measured relative to the 50% ...
  35. [35]
    Capacitor Discharge Calculation - HyperPhysics
    Capacitor Discharge Calculation​​ C = μF, RC = s = time constant. just after the switch is closed.
  36. [36]
    Overview of electrical measuring instruments, Part 3
    Apr 9, 2020 · Glide sweep, in which the input frequency increases or decreases logarithmically with respect to time. Stepped sweep, also called amplitude ...
  37. [37]
  38. [38]
    Buffer Amplifiers Solve VCO Problems - Analog Devices
    May 11, 2003 · This article describes key application issues surrounding VCO circuits such as load pulling, supply pushing, phase noise and effects of radiated ...Missing: generator ramp
  39. [39]
    [PDF] Design and Analysis of a Bootstrap Ramp Generator Circuit Based ...
    The bootstrap ramp generator circuits are capable of generating highly linear positive ramp waveforms. This paper presents an analysis and design of a voltage ...
  40. [40]
  41. [41]
    Capacitor i-v equation in action - Spinning Numbers
    A constant current driven into a capacitor creates a voltage with a straight ramp. This behavior is predicted by the integral form of the capacitor i i i- v v v ...
  42. [42]
    [PDF] A Technical Tutorial on Digital Signal Synthesis - IEEE Long Island
    This is the basic mechanism for generating a chirp waveform. Assuming that the Ramp Clock generates an clock pulse at regular intervals and the Delta.
  43. [43]
    [PDF] A Technical Tutorial on Digital Signal Synthesis - IEEE Long Island
    Direct digital synthesis (DDS) uses digital data processing to generate a frequency- and phase-tunable output signal referenced to a fixed-frequency clock.
  44. [44]
    FPGA controlled DDS based frequency sweep generation of high ...
    In this paper an FPGA controlled DDS based signal generator for highly linear frequency sweeps is introduced. Measurements demonstrate the approached ...
  45. [45]
    Waveform and Function Generators - Keysight
    In the 1990s, digital waveform generators using direct digital synthesis (DDS) became the mainstream technology, replacing analog waveform generators. A ...Trueform Series Waveform... · EDU33210 Series SBE...
  46. [46]
    [PDF] TECHNICAL JOURNAL - Bitsavers.org
    There are several methods employed in radar sweep circuits to improve the linearity versus time of the fundamental exponential sweep wave form. The first of ...
  47. [47]
    Sweep Signal Generator E-400 Equipment Precision Apparatus
    Sweep Signal Generator E-400 Equipment Precision Apparatus Co. Pacotronics; Brooklyn -, build 1948, 17 pictures, 1 schematics, 7 tubes, United States of.
  48. [48]
    Signal Generators — Part 1 - | Nuts & Volts Magazine
    The signal is generated in an L-C controlled variable frequency oscillator (VFO). The VFO typically has a bandswitch for selecting different frequency ranges.
  49. [49]
    [PDF] A History of the Analog Cathode Ray Oscilloscope - vintageTEK
    Two used gas focused tubes, one instrument had a sine wave sweep and the other a linear timebase. However the third and most ambitious model had a claimed ...
  50. [50]
    antique radio test instruments at The Museum of Yesterday
    Another mid-century standard of the radio and TV service industry, was the Precision Sweep Generator Model E-400. ... Competition among 1950s electronics kit ...
  51. [51]
    [PDF] MT-085: Fundamentals of Direct Digital Synthesis (DDS)
    A Technical Tutorial on Digital Signal Synthesis, 1999, Analog Devices, Inc. . 5 Direct Digital Synthesis Frequently Asked Questions, Analog Devices, Inc. 6 ...Missing: date | Show results with:date
  52. [52]
    Sweep Oscillator - HP Memory Project
    Evolution of Sweep Oscillators during the 1960 to 1980 Period. Looking back to the first generation of sweep frequency generator described in the first ...
  53. [53]
    VXG Microwave Signal Generators - Keysight
    Unmatched Power For 5G Applications · Reduce test system complexity with the 110 GHz vector signal generator and 5 GHz modulation bandwidth with channel bondingMissing: sweep 2020s