Computer cooling

Computer cooling encompasses the technologies and methods used to dissipate heat generated by electronic components in computing systems, such as central processing units (CPUs), graphics processing units (GPUs), and power supplies, in order to maintain safe operating temperatures and prevent performance degradation or hardware failure. This process is essential because computer hardware produces waste heat during electrical operations, and unchecked high temperatures, typically above 90 °C, can trigger thermal throttling—where clock speeds are automatically reduced—or cause irreversible damage like silicon degradation. Effective cooling not only sustains optimal performance but also extends component longevity, particularly in high-demand applications like , data centers, and scientific computing. The primary cooling techniques include , liquid cooling, and more specialized approaches like . , the most widespread method, relies on heatsinks—typically made of aluminum or fins—and fans to transfer from components to the surrounding air via , with case fans optimizing to exhaust hot air. Liquid cooling, conversely, circulates a (often or a water-glycol ) through blocks attached to hot components, a , tubing, and a where fans dissipate the absorbed , offering superior for overclocked or high-power systems. Advanced methods, such as , submerge entire systems in non-conductive fluids to directly absorb and transfer , reducing in large-scale environments like data centers. Thermal interface materials, like pastes or , are universally applied between components and coolers to enhance heat conduction by filling microscopic gaps. As computing densities increase—driven by trends like and denser chip architectures—innovations in cooling, including phase-change materials and microfluidic systems, are addressing emerging challenges to support sustainable and efficient operation (as of 2025).

Heat Generation and Effects

Sources of Unwanted Heat

The primary source of unwanted heat in computer systems arises from , also known as resistive or ohmic heating, which occurs when flows through resistive elements such as conductors, resistors, transistors, and integrated circuits () in components like central processing units (CPUs). This process converts electrical energy into according to the P = I^2 R, where P represents dissipation in watts, I is the current in amperes, and R is the electrical resistance in ohms. In CPUs and other , this heating is exacerbated by high current densities in interconnects and traces, leading to self-reinforcing temperature rises that increase resistivity and further amplify heat generation. A significant portion of heat in processors like CPUs and graphics processing units (GPUs) stems from dynamic power consumption during switching operations. This arises as transistors charge and discharge capacitive loads in complementary metal-oxide-semiconductor () circuits, governed by the equation P_{\text{dynamic}} = C V^2 f \alpha, where C is the load , V is the supply voltage, f is the clock , and \alpha is the activity representing the fraction of transistors switching per clock cycle. Higher frequencies and voltages, common in modern processors to achieve performance gains, quadratically increase this power dissipation, making it a dominant contributor in . In addition to dynamic power, static power dissipation in CMOS circuits arises from leakage currents, such as subthreshold and gate leakage, which flow even when transistors are off. This is modeled as P_{\text{static}} = I_{\text{leak}} V, where I_{\text{leak}} is the leakage current. In advanced nanoscale processes (e.g., 3 nm nodes as of 2025), static power can account for 30-50% of total dissipation due to increased leakage from quantum effects, significantly contributing to overall heat in idle or low-activity states. Additional heat sources include power supply units (PSUs), which dissipate energy as heat due to conversion inefficiencies—typically 10-20% of input power is lost as heat in efficient 80 PLUS-rated units under load. Hard disk drives (HDDs) generate heat through mechanical friction in spinning platters and electrical losses in their motors and read/write heads, often reaching operational temperatures of 40-50°C under sustained use. Light-emitting diodes (LEDs) in case lighting or displays contribute minor but measurable heat, as approximately 70% of their electrical input converts to thermal energy rather than light, particularly in backlit LCD panels where backlight LEDs drive higher power draw at increased brightness. Historically, early computers relied on vacuum tubes, which produced substantial heat due to high power requirements—often exceeding several watts per tube—and necessitated room-scale cooling systems in the 1940s and 1950s. The shift to semiconductors in the , particularly bipolar junction s and later , initially reduced per-device power dissipation by orders of , enabling more compact designs with natural cooling. However, , which observes that density on integrated circuits doubles approximately every two years, has driven escalating heat densities despite smaller feature sizes. This has resulted in modern chips exhibiting heat fluxes exceeding 100 W/cm² in hotspots, far surpassing the 0.5-10 W/cm² of early ICs and approaching levels comparable to re-entry conditions. In contemporary systems as of 2025, high-end CPUs such as the Ultra 9 285K and 9 9950X generate 100-300 W of (TDP) under load, reflecting the intense heat from billions of densely packed transistors. GPUs in high-end models, like the RTX 5090, can dissipate up to 575 W, amplifying overall system thermal challenges in graphics-intensive applications.

Damage Prevention

Overheating in poses significant risks to semiconductors, primarily through , a self-reinforcing process where rising temperatures decrease the internal resistance of the device, allowing higher currents to flow and generating even more heat. This phenomenon is particularly pronounced in bipolar junction transistors (BJTs), where the collector current increases exponentially with temperature due to reduced base-emitter , potentially leading to device destruction if not mitigated by external cooling. The junction temperature (Tj) of silicon-based chips must be maintained below typical maximum limits of 85–125°C to prevent irreversible damage, with commercial components often rated up to 85°C and industrial or high-reliability devices extending to 125°C. Exceeding these thresholds accelerates , where metal atoms in interconnects migrate under high current densities, causing voids and shorts that degrade performance over time. Similarly, oxide breakdown occurs as elevated temperatures weaken the insulating layers in MOSFETs and other transistors, leading to leakage currents and . Reliability metrics such as (MTBF) exhibit an exponential decline above 100°C, governed by the , where failure rates approximately double for every 10°C increase due to thermally activated degradation processes. To protect system integrity, modern processors implement CPU throttling, dynamically reducing clock frequency and voltage to cap power dissipation and prevent Tj from reaching destructive levels, though this sacrifices performance. Permanent damage from prolonged overheating includes in packages, where mismatches between die and encapsulant cause adhesive failures and cracks, compromising electrical connections. In extreme cases, overheating power supplies can ignite due to component failures like explosions or insulation breakdown, posing hazards in enclosed systems. Key thermal metrics like junction-to-case thermal resistance (θ_jc), measured in °C/W, quantify the heat transfer barrier from the junction to the package exterior, with lower values (e.g., 0.5–5 °C/W for high-power devices) indicating better dissipation efficiency essential for staying within safe operating ranges. Component-specific limits include (RAM) modules, which tolerate up to 85°C before data errors increase, and solid-state drives (SSDs), rated for a maximum of 70°C in commercial variants to avoid NAND flash degradation and warranty invalidation. In 2025, AI accelerators exemplify escalating challenges, with heat densities surpassing 200 W/cm² in high-performance GPUs and tensor processing units, necessitating sub-ambient cooling to avert rapid degradation and maintain yields in deployments.

Passive Cooling Techniques

Heat Sinks

A serves as a primary component in computers by absorbing heat from hot electronic parts, such as CPUs or GPUs, through conduction and dissipating it to the surrounding air via and . The device increases the surface area available for , enabling efficient thermal management without moving parts. The fundamental equation governing convective heat dissipation from the sink's surface is Q = h A (T_s - T_a), where Q represents the heat transfer rate in watts, h is the convective (typically 5–25 W/m²·K for natural in air), A is the effective surface area in square meters, T_s is the surface temperature of the sink in , and T_a is the ambient air temperature in . This relationship highlights how larger surface areas and temperature differentials drive higher heat rejection rates. Materials selection for heat sinks balances thermal performance, weight, and . Aluminum alloys, with a thermal conductivity of approximately 200 W/m·K, are widely used due to their lightweight nature ( around 2.7 g/cm³) and affordability, making them suitable for consumer-grade applications. In contrast, offers superior thermal conductivity of about 400 W/m·K, allowing faster heat spreading from the base to the fins, though its higher (8.96 g/cm³) and limit it to high-performance scenarios. Fin geometries further optimize dissipation: straight fins (plate-like) provide a simple, high-area design for unidirectional airflow, while pin fins (cylindrical or elliptical) enhance and omnidirectional by exposing more surface to the . Effective attachment to the heat-generating component is crucial to minimize interface resistance. Common methods include mechanical clips or screws for secure, removable mounting, and adhesives or epoxies for lightweight or vibration-prone assemblies, ensuring uniform (typically 10–50 ) to avoid air gaps. The conductive resistance through the sink's base plate is calculated as \theta = \frac{L}{k A}, where \theta is in K/W, L is the base thickness (often 3–10 mm), k is the material's , and A is the contact area; thinner bases reduce \theta but must withstand mechanical stress. Performance also depends on fin spacing, optimized to match the boundary layer thickness (around 5–10 mm in natural ) to prevent flow choking while maximizing coefficients. Heat sink designs have evolved significantly since the , when simple solid aluminum blocks sufficed for low-power processors under 50 W, to intricate finned structures in the incorporating heat pipes for better heat spreading. By the , advanced models integrate vapor chambers—flat, sealed devices using phase-change —for uniform distribution across larger bases, enabling handling of 200+ W thermal loads in compact forms. A representative example is the Noctua NH-D15, a dual-tower air cooler standing 168 mm tall (with fans) and capable of dissipating up to 250 W TDP through six heat pipes and aluminum fins. Emerging 2025 nanomaterials, such as coatings on fin surfaces, further enhance performance by boosting effective conductivity and reducing overall thermal resistance by approximately 20–25% compared to untreated aluminum. Heat sinks can be augmented with fans for , but their passive efficacy remains foundational for many systems.

Natural Convection and Radiation

Natural convection and radiation represent fundamental passive mechanisms for dissipating heat in computer systems, relying on buoyancy-driven airflow and electromagnetic emission without mechanical assistance. In natural convection, warmer air near a heat-generating component rises due to reduced density, creating a circulation that draws cooler ambient air into contact with the surface, thereby transferring heat through fluid motion. This process is quantified by the Grashof number, which determines the flow regime by comparing buoyancy forces to viscous forces: Gr = \frac{g \beta \Delta T L^3}{\nu^2} where g is gravitational acceleration, \beta is the thermal expansion coefficient, \Delta T is the temperature difference, L is the characteristic length, and \nu is kinematic viscosity. Radiation, meanwhile, involves the emission of thermal energy as infrared waves from the component's surface to the cooler surroundings, governed by the Stefan-Boltzmann law: Q = \epsilon \sigma A (T^4 - T_a^4) where Q is the net heat transfer rate, \epsilon is the surface emissivity, \sigma is the Stefan-Boltzmann constant ($5.67 \times 10^{-8} W/m²K⁴), A is the surface area, T is the absolute temperature of the emitting surface, and T_a is the ambient temperature. These mechanisms are particularly suited to low-heat-flux scenarios, where they provide silent, reliable cooling without energy consumption. In practical applications, natural and are employed in low-power computer devices such as routers and () sensors, where heat generation remains modest. designs often incorporate vents or chimneys to exploit the chimney effect, channeling rising hot air upward and promoting stack ventilation for improved airflow. For instance, electronic enclosures in settings use open grills and strategic component placement to optimize natural paths, reducing internal temperatures by 3–6°C without fans. Heat sinks can briefly enhance these processes by expanding the effective surface area available for both and . Despite their simplicity, these methods have inherent limitations, proving effective primarily for components dissipating less than 10 W, as higher heat densities overwhelm the low coefficients (typically 5–10 W/m²K for and comparable for ). They scale poorly with modern processors exceeding 50 W, where insufficient airflow leads to thermal throttling or failure, necessitating alternatives. To mitigate this, body coatings are applied to boost ; bare aluminum surfaces exhibit low around 0.09, while anodized or painted finishes increase it to 0.85–0.96, potentially enhancing radiative heat loss by up to 30% in passive setups. Historically, natural and enabled fanless designs in early personal computers, such as the 1977 , which relied on an efficient switching power supply and plastic case venting to manage heat from its 1 MHz processor without mechanical cooling. As of 2025, innovations in incorporate metamaterials for enhanced , such as photonic multilayers that achieve sub-ambient temperatures and reduce cooling energy by over 40% in like solar-integrated sensors. These advances, including nanoporous structures lowering device temperatures by 5–35°C, support sustainable, zero-energy thermal management in networks.

Active Air Cooling

Fans and Blowers

Fans and blowers are essential components in active air cooling systems for computers, facilitating the movement of air to dissipate heat from processors, graphics cards, and other heat-generating elements. These mechanical devices generate airflow through rotating blades or impellers, with performance characterized by metrics such as cubic feet per minute (CFM) for volume flow rate and millimeters of water (mmH2O) for static pressure, which measures the fan's ability to overcome resistance in the airflow path. Axial fans, commonly used in computer chassis for their high airflow and low static pressure, propel air parallel to the motor shaft, making them suitable for open environments where minimal resistance exists, such as general case ventilation. In contrast, centrifugal blowers generate high static pressure with lower airflow by redirecting air perpendicular to the intake, ideal for forcing air through restrictive components like dense heatsinks or dust filters. Typical axial fans in PCs deliver 40-80 CFM at 1-3 mmH2O, while centrifugal models achieve 2-10 mmH2O but with 20-50 CFM. Installation configurations affect overall system performance: fans in additively increase total while maintaining , useful for boosting volume in unrestricted spaces, whereas series arrangements cumulatively enhance at the cost of , beneficial for overcoming high-resistance paths. curves, which against at varying rotations per minute (RPM), illustrate these trade-offs; for instance, a typical 120mm axial might plot 60 CFM at 0 mmH2O dropping to 30 CFM at 2 mmH2O across 800-2000 RPM. Performance considerations include noise levels, measured in decibels A-weighted (), where quiet PC fans operate at 15-25 at low speeds, rising to 30-40 under load, and bearing types that influence durability. Sleeve bearings, lubricated with oil, offer initial quiet operation but degrade over time, with lifespans of 30,000-40,000 hours, while ball bearings provide greater longevity of 50,000-70,000 hours and consistent profiles, though often 1-3 louder due to mechanical contact. The cooling capacity of can be quantified using the equation for convective : Q = \dot{m} \cdot C_p \cdot \Delta T where Q is the heat transfer rate (in watts), \dot{m} is the mass flow rate of air (derived from CFM and air density), C_p is the specific heat capacity of air (approximately 1.006 kJ/kg·K), and \Delta T is the temperature difference between inlet and outlet air. This relation underscores how higher mass flow from fans enhances heat removal without excessive temperature rise. Modern fans incorporate (PWM) control via four-pin connectors, enabling variable speed adjustment from 0-100% based on temperature sensors, which optimizes cooling and reduces noise compared to fixed-speed or voltage-controlled () alternatives. In 2025, trends toward low-turbulence designs minimize airflow disruptions for improved in compact . Server-grade fans often feature IP55 ratings for and resistance, ensuring reliability in data centers by preventing ingress of particles that could impair cooling over extended operation. Effective integration requires balancing and exhaust fans to manage : positive pressure (higher CFM) expels dust through unfiltered gaps, reducing accumulation on components, while (higher exhaust) risks drawing in contaminants; neutral balance, with roughly equaling exhaust, promotes directed paths for optimal thermal performance.

Electrostatic and Corona Discharge Methods

Electrostatic and corona discharge methods, also known as electrohydrodynamic (EHD) cooling, utilize high-voltage to generate ion-driven for heat dissipation in devices, serving as a silent alternative to fans. The core principle involves , where a high-voltage ionizes surrounding air molecules, creating charged ions that are accelerated by the and collide with neutral air molecules, inducing bulk without any moving parts. This process, termed EHD flow, enables efficient convective cooling in compact spaces, particularly beneficial for noise-sensitive applications like laptops and servers. The typical setup consists of an of : a sharply pointed emitter electrode (e.g., wire or needle) held at high negative or positive voltage relative to a grounded collector electrode (e.g., plate or ), separated by a small gap of a few millimeters. When voltage exceeds the corona inception threshold, ions form near the emitter and drift toward the collector, entraining neutral air to produce directed flow. The average flow velocity v can be approximated as v \approx \mu E, where \mu is the ion mobility (typically 1-2 cm²/V·s for air ions) and E is the electric field strength, highlighting the direct proportionality to applied voltage. Operating voltages range from 5 to 20 kV to achieve sufficient ionization, with currents in the microampere range, resulting in low overall power consumption of 1-5 W per unit. Development of EHD cooling for computers accelerated in the , with early prototypes demonstrated by researchers in 2009, who integrated an ionic wind system into a to extract approximately 30% more heat than a conventional while consuming about half the power. By 2025, commercial adoption has emerged, exemplified by Ventiva's ICE9 technology, which employs EHD airflow for fanless cooling in laptops handling up to 100 W TDP, enabling ultra-thin designs as slim as 3 mm with airflow exceeding 1.5 CFM and silent operation below 15 . These systems offer advantages such as vibration-free performance, rapid thermal response, and suitability for small form-factor devices. Applications focus on auxiliary or primary cooling in portable electronics, where space constraints limit traditional fans. Despite these benefits, EHD methods face limitations including ozone generation as a of , which can degrade air quality and require mitigation through design or filtration, and safety concerns from high voltages necessitating . Additionally, the charged ions promote accumulation on and components, potentially reducing long-term unless addressed with periodic or anti-dust coatings. These challenges have historically confined EHD to niche roles, but ongoing refinements in materials and voltage control are enhancing reliability for broader integration.

Liquid-Based Cooling

Direct Liquid Cooling Loops

Direct liquid cooling loops, also known as custom water cooling systems, utilize a closed-circuit flow of to absorb, , and dissipate from high-performance computer components such as CPUs and GPUs. These systems emerged as an advancement over for enthusiasts and professionals seeking enhanced thermal management, particularly in scenarios where generation exceeds 200-300 watts per component. The core principle involves convective , where the liquid coolant extracts via direct contact with heated surfaces and then releases it to the ambient air through a . The primary components of a direct liquid cooling loop include a to circulate the coolant, flexible tubing such as PVC or for conveyance, water blocks that mount directly onto heat-generating chips to facilitate , and a equipped with fins and fans for dissipation. Coolants typically consist of or water-glycol mixtures, with water offering a high of approximately 4.18 J/g·K, enabling efficient thermal absorption without phase change. Pumps are selected based on and head pressure to overcome system resistance, often calculated using pressure drop formulas like the Darcy-Weisbach equation, ΔP = f (L/D) (ρ v² / 2), where f is the , L and D are pipe length and , ρ is , and v is . This ensures adequate circulation without excessive power draw, typically 5-20 watts for or inline pumps. Heat transfer in these loops follows the convective equation Q = ṁ C_p ΔT, where Q is the heat transfer rate, ṁ is the mass flow rate, C_p is the specific heat capacity, and ΔT is the temperature difference between inlet and outlet. This allows for precise sizing: for instance, a loop handling 300 W might require a flow rate of 1-2 liters per minute to maintain ΔT under 10°C. Types vary from single-loop configurations that cool multiple components like CPU and GPU in series, sharing the same coolant path for simplicity and cost-effectiveness, to custom multi-loop setups that isolate components for targeted cooling and reduced thermal interference. Maintenance is crucial, involving periodic checks for leaks via pressure testing, addition of corrosion inhibitors like benzotriazole to prevent mineral buildup in aluminum or copper parts, and coolant replacement every 6-12 months to sustain performance. Direct liquid cooling gained popularity in the community during the 2000s, with companies like introducing modular kits that enabled DIY assembly for enthusiasts pushing processor clocks beyond stock limits. By 2025, enterprise adoption has surged, exemplified by Intel's direct-to-chip cold plate designs in processors, capable of handling over 500 W per through integrated microchannels and high-flow manifolds, including experimental package-level solutions supporting up to 1000 W per CPU. Compared to , these loops achieve 10-20°C lower operating temperatures under load, reducing throttling and enabling sustained higher clock speeds, though air-liquid variants combine fans with loops for balanced and efficiency.

Immersion and Two-Phase Cooling

Immersion cooling involves submerging , such as servers and processors, directly into non-conductive fluids to remove heat efficiently, enabling higher power densities than traditional methods. This technique is particularly suited for environments like data centers, where it provides uniform temperature distribution across components without the need for fans or complex airflow management. fluids are essential, as they electrically insulate the while facilitating through or phase change. In single-phase immersion cooling, hardware is immersed in a non-boiling fluid, such as , which absorbs heat through natural or and transfers it to a secondary cooling loop, often via a . This approach maintains the fluid in a liquid state, avoiding , and is simpler to implement than phase-change systems, though it typically requires some form of circulation to prevent hotspots. Representative examples include synthetic oils or fluorinated compounds that remain stable at operating temperatures up to 100°C. Two-phase immersion cooling advances this by using low-boiling-point dielectric fluids, such as Novec 7100, which has a of 61°C at , allowing the fluid to vaporize upon heat absorption and leverage for enhanced cooling capacity. As the fluid boils, vapor rises and is condensed in an overhead before returning as liquid, creating a closed-loop cycle without pumps. This method excels in handling extreme heat loads, with the phase change providing significantly higher rates compared to single-phase . The core principle of two-phase cooling relies on boiling heat transfer regimes: nucleate boiling, where bubbles form at the heated surface, detach, and enhance mixing for high heat transfer coefficients (often 10,000–50,000 W/m²K); and the undesirable film boiling, where a vapor blanket insulates the surface, reducing efficiency. The (CHF) marks the transition point, typically around 40–100 W/cm² for dielectric fluids like Novec series in pool boiling configurations, beyond which overheating occurs. For instance, experiments with Novec 7000 have demonstrated a CHF of 43 W/cm² on flat surfaces. Applications of immersion cooling are prominent in data centers, where deployed two-phase systems in facilities starting in 2021, marking the first production-scale use by a major cloud provider to support dense and cloud workloads. These systems offer advantages like eliminating mechanical pumps for reduced failure points, achieving uniform cooling across racks, and enabling significant energy savings, including 5-15% reduction in server power consumption as reported by for two-phase systems, and up to 95% in cooling energy use compared to air-cooled setups. In hyperscale environments, expansions continue into 2025, with initiatives like and Shell's certified single-phase solutions enabling up to 40% reductions in cooling energy for high-density servers. Despite these benefits, challenges persist, including fluid compatibility with materials like plastics and metals, which can lead to or leaks if not properly vetted. Maintenance is complex in two-phase systems, requiring reliable condensers to manage vapor and prevent dry-out, alongside regular fluid monitoring for contamination. Sustainability concerns are rising due to the (PFAS) in many dielectric fluids, such as legacy products, prompting a phase-out by 2025 and driving research into non-PFAS alternatives to mitigate environmental persistence and health risks.

Advanced and Exotic Cooling

Thermoelectric and Phase-Change Systems

Thermoelectric cooling relies on the Peltier effect, a thermoelectric phenomenon where an electric current flowing through a junction of two dissimilar conductors absorbs heat at one junction and releases it at the other, enabling solid-state heat pumping without moving parts. This effect, related to the Seebeck effect through the Kelvin relations, produces a heat transfer rate given by Q = \Pi I, where Q is the heat absorbed, \Pi is the Peltier coefficient (dependent on material and temperature), and I is the current. Commercial thermoelectric modules based on this principle emerged in the 1960s and found early applications in portable refrigerators, leveraging their compact design for off-grid cooling. In computer systems, these modules provide precise temperature control for components like CPUs, though primarily in niche high-end or experimental setups due to power demands. Stacking multiple Peltier modules in cascade configurations amplifies the cooling , achieving sub-ambient temperatures down to -20°C by sequentially lowering the cold-side temperature across stages, with each additional layer increasing the total temperature differential. However, thermoelectric systems suffer from low efficiency, with coefficients of performance () typically below 1, meaning more electrical power is consumed than removed, and the hot side requires robust dissipation to prevent overall system overheating. Phase-change systems, such as heat pipes, transfer heat through a closed-loop evaporation-condensation cycle of a , typically or , sealed within a . At the end, heat input vaporizes the fluid, creating high-pressure vapor that flows to the , where it releases and condenses; in a porous then returns the liquid to the against or acceleration. This process yields effective thermal conductivities exceeding 10,000 W/m·K, orders of magnitude higher than (about 400 W/m·K), enabling efficient transport over short distances in . Heat pipes exhibit orientation sensitivity, as adverse tilts reduce liquid return and heat transport capacity by up to 50% or more, limiting their use in variable- or mobile applications without compensatory designs. Vapor chambers extend the heat pipe principle into a planar, two-dimensional format, using a thin, flat enclosure with a to spread heat laterally across a larger area, which is particularly effective for uniform cooling of high-heat-flux components like GPUs where localized hotspots exceed 100 W/cm². Loop heat pipes enhance this by decoupling the wick from the return path via separate vapor and liquid lines, allowing reliable operation over longer distances (up to several meters) with reduced sensitivity to orientation. Recent innovations include microchannel vapor chambers, which incorporate fine-scale channels (on the order of 100 μm) to boost heat spreading in compact form factors for processors.

Cryogenic and Chip-Integrated Approaches

Cryogenic cooling methods utilize extremely low-temperature fluids to dissipate heat from computer components, enabling operations far beyond the limits of ambient-temperature systems. (LN2), boiling at -196°C, is commonly employed in extreme scenarios, where specialized pots or containers hold the cryogen in direct contact with the processor to rapidly absorb heat through . These systems achieve evaporation rates that can cool processors to below -100°C under high loads, allowing clock speeds exceeding 7 GHz in , as demonstrated with FX-series CPUs pushed to 8 GHz. Liquid helium (LHe), with a of -269°C, offers even greater cooling potential but is more complex to manage due to its lower thermal conductivity of approximately 0.27 mW/cm·K at 4.2 compared to LN2's 1.38 mW/cm·K at 77 . In applications, sub-ambient cryogenic cooling reduces thermal resistance and leakage currents, enabling 20-30% higher clock speeds than air-cooled baselines by maintaining junction temperatures well below 0°C, thus preventing thermal throttling. For instance, LN2 setups have sustained multi-GHz overclocks on high-end CPUs during short-duration benchmarks, leveraging the cryogen's high of vaporization for efficient . In quantum computing, LHe-based dilution refrigerators achieve millikelvin temperatures—down to 50 mK—essential for superconducting qubits, with 2025 advancements incorporating cryogen-free designs to scale systems for commercial use. Chip-integrated cooling approaches embed thermal management directly into the substrate, minimizing thermal gradients in dense, high-power-density circuits. Microchannels etched into the backside of 3D integrated circuits (3D ICs) facilitate direct liquid flow, as pioneered by in demonstrations of fluidic networks integrated with stacked dies. These microchannels, often 50-100 μm wide, enhance convective coefficients up to 10,000 W/m²·K, enabling sustained operation of multi-layer processors at power densities exceeding 100 W/cm². On-chip synthetic jets and electroosmotic pumps represent compact, solid-state innovations for localized cooling without external fans. Synthetic jets, generated by oscillating diaphragms to create zero-net-mass-flux fluid pulses, have been adapted for liquid cooling in high-flux electronics, achieving heat removal rates comparable to microchannel systems while reducing pumping power by up to 30%. Electroosmotic pumps, leveraging to drive flow through microchannels without , integrate seamlessly into VLSI for closed-loop cooling, delivering flow rates of 1-10 μL/min at voltages below 100 V. By 2025, such integrated have improved efficiency in advanced processors, supporting higher in stacked architectures akin to those in emerging accelerators.

Optimization Strategies

Thermal Interface Materials

Thermal interface materials (TIMs) are specialized substances applied between heat-generating components, such as CPUs or GPUs, and cooling elements like heat sinks to minimize resistance and enhance efficiency. These materials fill microscopic air gaps and surface irregularities at the interface, which can otherwise impede heat conduction due to air's low thermal conductivity of approximately 0.026 W/m·K. By reducing this , TIMs ensure more effective dissipation of heat, preventing thermal throttling and extending component lifespan in computing systems. Common types of TIMs include thermal pastes, pads, and phase-change materials. Thermal pastes, often grease-like compounds filled with particles such as zinc oxide (ZnO) or aluminum oxide (Al₂O₃), exhibit thermal conductivities ranging from 1 to 12 W/m·K and are typically applied in a thin layer of about 0.1 mm thickness to optimize performance without adding excess resistance. Thermal pads, made from silicone or ceramic-infused materials, provide a solid, compressible interface suitable for uneven surfaces and offer conductivities around 1-6 W/m·K, though they may introduce slightly higher resistance than pastes due to their thickness. Phase-change pads, which transition from solid to semi-liquid at operating temperatures (around 45-60°C), combine the ease of pad application with paste-like flow to fill gaps more effectively, achieving conductivities up to 8.5 W/m·K. The performance of TIMs relies on their ability to conform to surface asperities, thereby lowering the interface thermal resistance, defined as θ_int = d / k, where d is the material thickness and k is its thermal conductivity. However, over time, especially under repeated thermal cycling, thermal pastes can degrade through a process known as pump-out, where the paste is extruded from the interface due to expansion and contraction, leading to increased temperatures by 10-20°C in high-power applications. This degradation is exacerbated in GPUs or overclocked systems, necessitating periodic reapplication every 1-3 years depending on usage. For demanding scenarios requiring ultra-low resistance, metal-based TIMs such as indium foils or liquid metals like gallium-indium (GaIn) alloys offer conductivities exceeding 70 W/m·K, far surpassing traditional pastes. provides a stable, solderable interface with minimal pump-out, while GaIn liquid metals excel in direct-die cooling but pose risks of electrical shorting if they migrate to nearby circuits due to their conductivity. These alternatives demand careful application, often with barriers, to avoid device failure. Pioneering products like Arctic Silver, introduced in the late , popularized silver-filled pastes with conductivities around 8.9 W/m·K, setting benchmarks for enthusiast cooling. Recent advancements, such as graphene-enhanced pastes and pads in 2025, have demonstrated temperature reductions of up to 10°C under load compared to standard formulations, thanks to graphene's exceptional in-plane conductivity of over 1000 W/m·K. Additionally, emerging sustainable and non-toxic TIMs, incorporating or silicone-free composites, address environmental concerns by avoiding and volatile compounds, maintaining performance while being biodegradable or recyclable.

Airflow and Component Arrangement

Effective in computer relies on directing cool air from points to heat-generating components and expelling hot air through exhaust vents, typically following a front-to-back path to maintain a unidirectional flow that minimizes and recirculation. This ensures that ambient air enters through front and bottom panels, passes over critical , and exits via rear and top fans, reducing overall system temperatures by up to 5-10°C compared to bidirectional setups. Positive internal pressure, achieved by configuring 1-2 more intake fans than exhaust fans, further enhances this by forcing air out through unfiltered gaps while drawing filtered intake air inward; however, empirical tests indicate similar dust accumulation across positive, neutral, and setups when intake fans are filtered. Hot components like CPUs and GPUs are optimally placed near exhaust vents—such as at the rear or top of the tray—to shorten the path for heated air removal, preventing hotspots and improving in high-load scenarios. techniques, including rounding and bundling wires away from airflow paths, reduce impedance by minimizing obstructions that can increase flow resistance by 10-20%, allowing smoother air movement without additional fan power. Key techniques for optimizing airflow include installing magnetic dust filters on intake panels to capture particulates while maintaining 80-90% of unrestricted flow rates, and using perforated metal or mesh panels on front and side covers to increase surface porosity for better intake without compromising structural integrity. Computational fluid dynamics (CFD) simulations are widely employed in chassis design to model and refine these elements, predicting velocity profiles and pressure drops to achieve up to 15% better cooling performance before prototyping. The ATX standard, introduced by Intel in 1995 as an evolution from Baby-AT for improved expandability and I/O access, laid the foundation for modern chassis layouts by standardizing motherboard orientation to support this front-to-back airflow. In 2025, modular cases like the O11 series exemplify advanced designs with pillar-less frames and slanted bottoms that channel airflow directly to GPUs, prioritizing thermal performance over aesthetic features like RGB lighting. Emerging AI-optimized layouts in consumer PCs use to dynamically adjust curves and predict component based on usage patterns, further refining arrangement for reduced noise under load. resistance within chassis ducts or channels can be quantified using the Darcy-Weisbach equation, h_f = f \frac{L}{D} \frac{v^2}{2g}, where h_f is head loss, f is the , L/D is the length-to-diameter ratio, v is velocity, and g is , helping designers minimize pressure drops in confined spaces.

Applications by System Type

Laptops and Mobile Devices

Laptops and mobile devices, constrained by portability and life, rely on compact cooling solutions to manage from increasingly powerful yet space-limited components. These systems prioritize passive and semi-passive methods to minimize , weight, and power draw, often integrating and microstructures to dissipate efficiently within thin form factors. Unlike larger desktops, cooling here must balance thermal performance with user comfort, such as preventing hot surfaces on keyboards or device casings. Vapor chambers, combined with heat pipes, are widely adopted in ultrabooks and slim laptops to spread evenly across larger surfaces before via fans or conduction. A vapor chamber operates by evaporating a (typically ) at the heat source, allowing vapor to travel and condense at cooler areas, enabling superior over traditional heat pipes alone in confined spaces. For instance, manufacturers like and Razer incorporate vapor chambers in high-performance models to cover broader areas, reducing hotspots and supporting thinner designs without sacrificing cooling capacity. Heat spreaders, often made of or copper-infused materials, are placed under keyboards and to distribute away from user-contact areas, preventing discomfort during prolonged use. The thin profiles of these devices, typically 5-15 mm in Z-height, severely limit paths, forcing reliance on minimal sizes or passive dissipation and increasing the risk of elevated internal temperatures. In tablets and smartphones, this constraint exacerbates thermal , where processors dynamically reduce clock speeds to avoid overheating, potentially dropping performance by 20-50% under sustained loads like or . For example, mobile SoCs in these devices often throttle after minutes of high activity due to enclosed designs lacking robust . Innovations in the 2020s have addressed these issues through material shifts and novel integrations. Apple introduced graphite sheets in the 2024 M4 iPad Pro chassis, enhancing thermal performance by 20% via improved conduction and pairing with a copper-infused for better heat spreading. Micro-fans such as the 1 mm-thick silicon-based XMC-2400 from xMEMS Labs, introduced in 2024 and available for sampling in 2025, enable in ultra-thin profiles for devices like foldables, providing targeted airflow without bulky components. Power constraints further shape cooling strategies, with undervolting—reducing CPU voltage slightly below levels—emerging as a key technique to lower output and extend battery life by 10-30% in laptops, while maintaining or even boosting sustained performance by curbing throttling. dominates for system-on-chips (SoCs) under 15 W, common in tablets and low-end phones, relying on heat spreaders and natural to avoid fans entirely and preserve and .

Embedded and High-Performance Systems

In embedded systems, such as routers and switches, passive heat sinks made from materials like aluminum or are widely employed to dissipate heat through natural , supporting continuous 24/7 operation without the need for fans or additional power consumption. These heat sinks attach directly to high-heat components like processors and network chips, enhancing reliability in space-constrained networking equipment where would increase complexity and failure points. Automotive embedded electronics face extreme environmental stresses, including temperature fluctuations from -40°C to 85°C, necessitating protective conformal coatings such as silicones or parylenes that encapsulate boards to prevent , ingress, and thermal degradation. Silicone-based coatings, in particular, maintain integrity and flexibility across this range, ensuring operational stability in control units and modules exposed to vibration and contaminants. To manage thermal output in low-power applications, techniques like undervolting and dynamic voltage and (DVFS) are applied, particularly in ARM-based cores operating below 5W, allowing software to adjust supply voltage in for reduced draw and heat while preserving performance margins. DVFS operates as an open-loop system where monitors workload demands and scales voltage dynamically, improving energy efficiency in IoT devices and edge controllers without hardware modifications. High-performance embedded systems, including those in edge and , incorporate advanced cooling like piezoelectric fans, which use ultrasonic vibrations of a membrane to generate airflow in compact, fanless designs that are 96% smaller than traditional fans and suitable for dustproof, low-noise environments. xMEMS's XMC-2400 provides in 1mm thickness with inaudible operation, while Frore Systems' similar MEMS-based solutions offer low-noise cooling suitable for dustproof environments. In extreme high-performance non-consumer applications, such as base stations, liquid cooling systems are increasingly integrated to handle high power densities, using coolants circulated through cold plates to maintain component temperatures below 70°C and reduce use by up to 30% compared to . Nokia's AirScale exemplifies this, supporting all radio access technologies with liquid-cooled basebands that lower CO2 emissions through efficient heat rejection. For (HPC) clusters, chip-integrated enable direct heat extraction by embedding microchannels within interposers or 3D-stacked ICs, achieving rates over 1000W/cm² while minimizing resistance between the heat source and coolant. As of 2025, innovations like Microsoft's chip-integrated microfluidic cooling enable direct liquid flow through etched channels in , handling extreme heat in AI and HPC applications. These systems, often using fluids, address the limitations of traditional cooling in multi-core processors by integrating fluidic networks at the package level, as demonstrated in on microfluidic interposers for HPC workloads. Soft cooling strategies complement this hardware through firmware-level tweaks, such as dynamic undervolting, which adjust voltage margins based on performance counters to balance loads and reliability in multicore environments.

References

  1. [1]
    PC Cooling: The Importance of Keeping Your PC Cool - Intel
    There are many ways to keep a CPU cool, from mineral oil to passive cooling, but by far the most popular solutions are air or liquid CPU coolers. These coolers ...Missing: authoritative | Show results with:authoritative
  2. [2]
    Data Center Liquid Cooling: The AI Heat Solution - IEEE Spectrum
    Oct 13, 2025 · The liquid is usually water, with some glycol added to prevent bacterial growth, stabilize the temperature, protect against freezing and ...
  3. [3]
    Guide to Types of Computer Cooling Systems
    ### Types of Computer Cooling Systems for Encyclopedia Entry
  4. [4]
    Immersion Cooling: Dunking Computers to Keep Them Cool
    Jun 13, 2024 · Submerging computers in a synthetic nonconductive oil may be far better at cooling them than other strategies. Sustainable Metal Cloud and ...Missing: techniques | Show results with:techniques
  5. [5]
  6. [6]
    The Influence of the Joule Heating Effect on PCBs and ICs
    Dec 16, 2022 · The Joule heating effect can be described as the power loss in the form of heat energy in a conductor, PCB trace, or interconnect in an IC.
  7. [7]
    2.1.1. Dynamic Power Equation - Intel
    The following equation shows how to calculate dynamic power where P is power, C is the load capacitance, and V is the supply voltage level.
  8. [8]
    Question regarding power supply heat output | TechPowerUp Forums
    Nov 17, 2019 · When the computer demands more from the PSU, the PSU will produce more heat. When the demand is lower, the PSU will produce less heat. That has ...
  9. [9]
    Hard Drive Temperatures: Be Afraid - Coding Horror
    Dec 17, 2006 · Hard drives are very temperature sensitive; high temperatures increase failure risk. 45C+ temperatures mean improved airflow is needed to avoid ...
  10. [10]
    3 Minutes To Tell You Why LED Displays Heat Up When In Use?
    Sep 24, 2024 · The LED display will heat up when it is working because most of the energy is converted into heat energy when it converts electrical energy into light energy ...
  11. [11]
    The history of power dissipation | Electronics Cooling
    Jan 1, 2000 · Moore's Law or Curse. For several decades Moore's law has served as a beacon to predict device density and its subsequent power dissipation.
  12. [12]
    Optimising Integrated Heat Spreaders: CPU Cooling Case Study
    The heat fluxes of the selected CPUs range between around 50 W/cm2 to over 110 W/cm2, and this can be considered conservative, since the CPU cores occupy only ...Missing: cm² | Show results with:cm²
  13. [13]
    A review of heat pipe application including new opportunities
    The escalating heat dissipation in modern processors, exceeding 100 W with heat fluxes surpassing 100 W/cm², renders passive cooling inadequate. While ...
  14. [14]
    Intel® Core™ Ultra 9 Processor 285K (36M Cache, up to 5.70 GHz)
    36 MB Intel® Smart Cache ... Total L2 Cache ... 40 MB ... Processor Base Power ... 125 W ... Maximum Turbo Power ... 250 W ... Intel® Deep Learning Boost (Intel® DL Boost) on ...
  15. [15]
    AMD Ryzen™ 9 9950X
    The AMD Ryzen 9 9950X has 16 cores, 32 threads, up to 5.7 GHz boost clock, 64MB L3 cache, 170W TDP, and 192GB max memory. It is for gaming and creating.
  16. [16]
    NVIDIA GeForce RTX 5090 Specs - GPU Database - TechPowerUp
    Being a dual-slot card, the NVIDIA GeForce RTX 5090 draws power from 1x 16-pin power connector, with power draw rated at 575 W maximum. Display outputs include ...Gigabyte aorus rtx 5090... · Inno3D RTX 5090 iCHILL... · Palit RTX 5090 GameRock
  17. [17]
    BJT Quirks | Bipolar Junction Transistors | Electronics Textbook
    The hotter transistor draws more current resulting in thermal runaway. The solution when paralleling bipolar transistors is to insert emitter resistors ...
  18. [18]
    Analyzing thermal runaway in semiconductor devices using the ...
    Thermal runaway is a major cause of failure of semiconductor devices in electronic systems. Analyzing the conditions for thermal runaway and its prevention ...
  19. [19]
    Chip Temperature - an overview | ScienceDirect Topics
    The application temperatures of traditional power devices based on silicon (Si) have been limited to 125–175 °C due to leakage current and breakdown voltage ...Missing: electromigration | Show results with:electromigration
  20. [20]
    [PDF] The Influence of Temperature on Microelectronic Device Failure ...
    Sep 4, 1993 · trapping, hot electrons, electrical overstress, electrostatic discharge, dielectric failure, oxide breakdown, and electromigration. First ...
  21. [21]
    [PDF] Failure Mechanisms and Models for Semiconductor Devices JEP122H
    Sep 5, 2016 · ... temperature is near 100 °C. With those parameters every. 20 °C change in temperature will change the rate by ~3-fold. Thus, ±20 °C will ...
  22. [22]
  23. [23]
    The Long-Term Damage of Computer Overheating - LinkedIn
    Apr 10, 2024 · The materials expand when they get hot and contract when they cool down. Over time, this can cause physical damage, such as warping or cracking.
  24. [24]
    Did You Know? Laptop Power Supplies and House Fires - Ting
    Laptop power supplies can cause devastating electrical fires stemming from electrical failure or misuse. While these fires are not a common occurrence, they ...
  25. [25]
    Junction-to-Case Thermal Resistance in Thermal Design
    Dec 30, 2020 · θJC specifies the thermal resistance from junction to the case surface. To avoid confusion, manufacturers may specify the surface in ...
  26. [26]
    [PDF] MT-093 Tutorial: Thermal Design Basics - Analog Devices
    θJC = Junction-Case Thermal Resistance. θCA = Case-Ambient Thermal Resistance ... A heat sink has additional thermal resistance of its own, θCA, rated in °C/W.
  27. [27]
    SSD Operating Temperature:Standard, Extended, and Industrial ...
    Feb 14, 2025 · Depending on application needs, SSD operating temperature typically falls into three categories: S-Temp,Standard Temperature: 0℃ ~ 70℃ / 0℃ ~ 85 ...
  28. [28]
    Semiconductor Microchip Thermal Management Technology Market ...
    On the growth side, semiconductor devices now routinely dissipate heat densities above 200 W/cm², while high-performance GPUs and AI accelerators often exceed ...
  29. [29]
    Thermal - Heterogeneous Integration Roadmap, 2023 Version
    Critical heat flux levels are from 200 to 1000 W/cm². The EHFµ-Cooler represents more than 10× reduction in thermal resistance, an unprecedented CHF >1 kW ...
  30. [30]
    [PDF] Thermal Management for Electronic Packaging
    Mar 2, 2006 · Convection: is a mode of heat transport from a solid surface to a fluid and occurs due to the bulk motion of the fluid. Newton's law: Q= hA (Tw- ...Missing: equation | Show results with:equation
  31. [31]
    Thermal Conductivity - HyperPhysics
    Thermal Conductivity ; Copper. 0.99. 385.0 ; Gold ... 314 ; Brass ... 109.0 ; Aluminum. 0.50. 205.0 ; Iron. 0.163. 79.5.
  32. [32]
    What is The Thermal Performance of Straight Fin, Pin Fin and Other ...
    Mar 27, 2014 · This article discusses the effects of air flow velocity on the experimentally determined thermal resistance of different heat sink designs.
  33. [33]
    [PDF] Heat Sink Attachment Options - Advanced Thermal Solutions, Inc.
    In general, Thermal Tape and Epoxy adhesive methods are the most cost effective, but are only useful on small (low mass) heat sinks. Z-Clips, and especially ...
  34. [34]
    [PDF] Heat Sink Design Facts & Guidelines for Thermal Analysis - DigiKey
    Convection cooling is used. •. Fin-to-Fin Spacing should typically be greater than ~0.250”, (6mm+) ... • δ – boundary layer increases as x (distance from leading ...
  35. [35]
    [PDF] Evolution of the Heatsink Technology
    Jul 1, 2006 · EVOLUTION PROCESS OF HEATPIPE. TECHNOLOGY. Here let us describe the trends in heatsinks focusing on those for personal computers.
  36. [36]
    Vapor Chamber Heatsink - Radian Thermal Products
    Vapor Chamber Heatsinks are constructed using a vapor chamber as the base of the heatsink with stamped fins soldered to the chamber.Missing: 2020s | Show results with:2020s
  37. [37]
    NH-D15: Specifications - Noctua
    Height with fan(s). 168 mm. Height without fan(s). 160 mm. Width with fan(s). 150 mm. Width without fan(s). 150 mm. Depth with fan(s). 161 mm. Depth without fan ...
  38. [38]
    Noctua NH-D15 G2 Review: Not worth $150 | Tom's Hardware
    Aug 23, 2024 · Average Maximum TDP (Our Testing), ~240W with Intel's i7-14700K. Installed Size (with fans), 168mm (H) x 150 mm (W) x 152mm (D). Weight, 1525g ...
  39. [39]
    Highly thermal conductive graphene-based heatsink tailored for ...
    Apr 15, 2024 · The integration of graphene in the heatsink design demonstrates notable improvements, including a 24.4 % increase in the heat transfer ...
  40. [40]
    None
    ### Summary of Natural Convection from the Document
  41. [41]
    Calculation Corner: A Simple Method for Estimating Radiation Heat ...
    Feb 13, 2024 · This article describes a simple approach for estimating the effects of radiation and comparing them to conduction and convection thermal resistances.
  42. [42]
    [PDF] Natural Convection Cooling of Electronic Enclosure
    Natural convection cooling is widely used for electronic enclosures due to its simplicity, low costs, no extra power, minimum maintenance, and high reliability.<|separator|>
  43. [43]
    The importance of radiation in heat sink design | - HeatSinkCalculator
    Jul 27, 2015 · The emissivity is a measure of how well the surface radiates heat compared to a blackbody. Values for common heat sink surface finishes and ...Missing: coatings | Show results with:coatings
  44. [44]
    Fanless Cooling Designs For industrial PC Computers - Premio Inc
    To avoid your fanless PCs overheating, you want to get a CPU ranging from around 10W to 65W of TDP. Having a TDP higher than that, such as CPUs with 95W of TDP ...Missing: limitations | Show results with:limitations
  45. [45]
    Radiative cooling applications toward enhanced energy efficiency
    Oct 6, 2025 · Radiative cooling utilizes the ultracold (∼3 K) deep space to cool terrestrial objects at no cost to active energy consumption.
  46. [46]
    Comparing Axial Fans and Centrifugal Fans - DigiKey
    Mar 22, 2022 · The airflow that axial fans produce is high volume, but low pressure. This high-volume, low-pressure output makes them well-suited for cooling ...
  47. [47]
    Fan Basics: Air Flow, Static Pressure, and Impedance
    Oct 25, 2019 · In this post, I will be discussing the definitions of air flow vs static pressure, the relationship between them, and the importance of impedance.
  48. [48]
    Centrifugal Fans vs Axial Fans: What is the Difference?
    Apr 23, 2023 · The biggest difference between centrifugal and axial fans is their blade angle. A centrifugal fan will have blades angled in different directions for different ...
  49. [49]
    Axial fans in series or parallel operation | Noctua
    When fans are operating in parallel, the combined performance shows an increased volume of airflow. In theory, the total airflow volume will be doubled compared ...Missing: RPM | Show results with:RPM
  50. [50]
    Fan air volume and static pressure | Basic knowledge of fans
    Feb 2, 2024 · For instance, using two identical fans in series theoretically doubles the static pressure, while using them in parallel doubles the airflow.
  51. [51]
    [PDF] FAN ENGINEERING - Aerovent
    For a more in-depth look into the characteristics of different fan types, refer to FE-2300 for axial fans and. FE-2400 for centrifugal fans. Pressure Volume ...Missing: computer cooling
  52. [52]
    A Comprehensive Guide to Different Types of Fan Bearings
    May 25, 2023 · Sleeve bearings have a lifespan of around 30,000 to 40,000 hours, and while they are generally quieter at the beginning of their life, the noise ...Missing: dBA | Show results with:dBA
  53. [53]
    COOLING FAN NOISE - SLEEVE BEARING VS BALL BEARING
    This data supports the fact that, all else being equal, most ball bearing fans are noisier by 1 to 3 dBA over their counterpart sleeve-bearing fan. Also the ...Missing: lifespan | Show results with:lifespan
  54. [54]
  55. [55]
    3.12: Energy and Heat Capacity Calculations - Chemistry LibreTexts
    Jul 28, 2025 · The equation that relates heat ( q ) to specific heat ( c ... c p = q m × Δ ⁢ T = 134 J 15.0 g × 38.7 o ⁢ C = 0.231 J/g o ⁢ ...<|control11|><|separator|>
  56. [56]
    Why and How to Control Fan Speed for Cooling Electronic Equipment
    PWM Control: The prevalent method currently used for controlling fan speed in PCs is low-frequency PWM control. In this approach, the voltage applied to the fan ...
  57. [57]
    PWM vs. DC Fans: Fan Speed Control Strategies for CPU Cooling ...
    Jul 17, 2024 · The speed variation of cooling fans is within 30-100% of the rated speed, with the PWM technique and the minimum speed achieved by PWM fans ...
  58. [58]
    Top PC Fans for Optimal Cooling and Performance in 2025
    Apr 17, 2025 · The innovative aerodynamic design significantly reduces turbulence, optimizing cooling efficiency and addressing the common challenge of ...Be Quiet! Pure Wings 2 120mm... · Noctua Nf-A12x25 Pwm Fan · Arctic P12 Pwm Pst Fan
  59. [59]
    IP55 Rated Cooling Fans - NMB Technologies - DigiKey
    Jan 20, 2023 · NMB's IP55 rated cooling fans with ingress protection are dust and water-resistant, and provide protection against harsh environments, ...Missing: grade | Show results with:grade
  60. [60]
    Delta IP55 Axial Fans
    Delta Ingress Protection (IP) rated fans are purpose-built with superior production techniques to prevent dust and water ingress in harsh conditions.
  61. [61]
  62. [62]
    Case Airflow: Positive or Negative Pressure? - Tom's Hardware Forum
    May 23, 2007 · Positive - there is more fresh air coming into the case than there is hot air exiting the case. Basically, the CFM from intake fans exceeds the CFM from ...Positive or negative air pressure? (case fan cooling)[SOLVED] - How should I balance airflow? - Tom's Hardware ForumMore results from forums.tomshardware.com
  63. [63]
    Fan Speeds and Case Air Pressure - Cooling - Corsair Community
    Jan 25, 2018 · If you have more intake air flow than exhaust, pressure will build in the case. In a heavily vented case, this will push air out of those vents.
  64. [64]
    Analytical model of electro-hydrodynamic flow in corona discharge
    Aug 13, 2018 · We present an analytical model for electro-hydrodynamic flow that describes the relationship between the corona voltage, electric field, ...Missing: computer | Show results with:computer
  65. [65]
    The Study of EHD Flow:Velocity and electrical power - ResearchGate
    Electrohydrodynamics (EHD) flow is the yield of the corona discharge. Corona discharge characterized by electrical phenomena that occur together in a gas ...<|control11|><|separator|>
  66. [66]
    Electrohydrodynamic (EHD) | Power Supply - Matsusada Precision
    Electronic equipment cooling, air purification, static elimination (ionizers). ... ±1 to ±10 mA. Power: 3 to 10 W. Compact and high performance High voltage ...Missing: consumption | Show results with:consumption
  67. [67]
    A Laptop Cooled with Ionic Wind - MIT Technology Review
    May 19, 2009 · The system can extract roughly 30 percent more heat from a laptop than a conventional fan can, and lab tests show that it could potentially consume only half ...
  68. [68]
    [PDF] A Breakthrough in Laptop Thermal Management - Ventiva
    Ventiva's patented Ionic Cooling Engine (ICE®) technology harnesses electrical energy to create the same effect, working on the principle of electrohydrodynamic ...Missing: EHD rate
  69. [69]
  70. [70]
  71. [71]
    Ozone production from Corona Discharge - Oxidation Technologies
    In a corona discharge ozone generator, the electrical discharge will take place in an air gap within the corona cell designed specifically to split the oxygen ...
  72. [72]
    Overclocking a CPU to 7 GHz with the science of liquid nitrogen
    Jun 9, 2017 · Bringing the CPU temp down is as simple as pouring LN2 into the pot and watching the numbers drop until it reaches -196 degrees Celsius.Missing: >8GHz | Show results with:>8GHz
  73. [73]
    [PDF] heat transfer
    Table 6. Thermal conductivity for some common cooling fluids [mW/cm.K]. Water at 300K. 6. Oil at 300K. 1.3. Nitrogen at 77K. 1.38. Helium at 4.2K. 0.27. 2.4 ...
  74. [74]
    Overclocking and the AMD Ryzen Threadripper 7000 Series
    Nov 20, 2023 · Using liquid nitrogen (LN2) to push these chips to their limits, we've observed some significant performance jumps, highlighting the true ...
  75. [75]
    ElmorLabs Volcano LN2 Container
    $$260.00 In stockThis compact and lightweight pot is the ultimate tool for achieving extreme overclocking performance, using either liquid nitrogen or liquid helium to cool your ...<|separator|>
  76. [76]
    Cooling Quantum Computer Chips - Advanced Thermal Solutions, Inc.
    Apr 18, 2025 · Quantum computer cooling from dilution refrigerator systems, the most common cryo technology, can bring qubits to about 50 millikelvins above absolute zero.
  77. [77]
    Dilution Refrigerator: Everything You Need to Know [2025] - SpinQ
    May 30, 2025 · A dilution refrigerator works by using a quantum mechanical process involving two isotopes of helium—helium-3 (³He) and helium-4 (⁴He)—to ...Missing: liquid | Show results with:liquid
  78. [78]
    A 3D-IC technology with integrated microchannel cooling for IITC 2008
    Sep 9, 2008 · A 3D-IC technology with integrated microchannel cooling is demonstrated in this paper. Fluidic interconnect network fabrication proceeds at ...
  79. [79]
    Liquid synthetic jets for high flux electronics cooling - ScienceDirect
    Feb 15, 2025 · This study presents an approach to high-efficiency, low-energy liquid cooling using liquid synthetic jet devices.
  80. [80]
    [PDF] Closed-loop electroosmotic microchannel cooling system for VLSI ...
    The system consists of an electroosmotic pump, a microchannel heat exchanger and a heat rejecter. The working principle of the electroosmotic pump is based on ...
  81. [81]
    [PDF] Through-chip microchannels for three-dimensional integrated ... - arXiv
    Fluid cooling with microchannel heat sinks (MCHSs) is one of the most promising strategies for 3D. IC cooling. It has been intensively studied over the past few ...
  82. [82]
    Thermal Interface Materials: Transfer Heat Between Solid Surfaces
    Thermal Interface Materials (TIMs) are engineered materials that enhance thermal conductivity between two mating surfaces by facilitating more efficient heat ...
  83. [83]
    The Role of Thermal Interface Materials and How They Affect ...
    Jul 13, 2024 · The two broad classes of thermal interface materials that best satisfy these requirements are thermal pastes and thermal pads. Thermal pastes ...Thermal Tape Or Adhesive · Thermal Pads · Thermal Epoxy
  84. [84]
    Overview of Thermal Interface Materials for Electronics
    Thermal interface materials are designed to aid heat transfer from hot areas of a PCBA into cooler areas, like a heatsink or even the enclosure.Thermal Interface Material... · Thermal Greases/phase-Change... · Thermal Pads
  85. [85]
    Thermal Interface Materials | Laird Technologies
    Types of Thermal Interface Materials · Thermal Tapes · Greases · Gels · Thermal Adhesives · Dielectric Pads · Phase Change Materials or PCMs · Advanced Materials.
  86. [86]
    PTM7950 Thermal Pad Phase Change Heatsink 80x80x0.25mm 8.5 ...
    PTM7950 Thermal Pad is designed to minimize thermal resistance at interfaces, maintain excellent performance through reliability testing, and provide scalable ...
  87. [87]
    [PDF] Basics of Thermal Resistance and Heat Dissipation
    Thermal resistance for thermal conduction is represented with the following figure and equations. Temperature difference (T1 − T2). = Tℎermal resistance Rtℎ × ...Missing: θ_int = d /
  88. [88]
    Thermomechanical Degradation of Thermal Interface Materials
    May 21, 2020 · This type degradation presents itself mainly through the occurrence of TIM pump-out, which is compounded by the accelerated mechanical cycling ...
  89. [89]
    [PDF] Influence of Thermal Cycling on Degradation ... - Purdue e-Pubs
    The thermal grease retains its shape and form through out the cycling period indicating minimal impact of thermal cycling on the pump-out. B. Relation between ...
  90. [90]
    Metal TIMs 101: Chapter 2 - Indium Corporation
    The patterned metal helps to improve the thermal interface conductivity by eliminating air pockets between the TIM and heat-sink and the TIM and IC. Good ...Missing: GaIn shorting
  91. [91]
    Liquid metal (LM) and its composites in thermal management
    Moreover, leakage of LM-based TIM usually occurs in thermal management application, which increases the risk of short circuit of electronic devices and restrict ...Missing: shorting | Show results with:shorting
  92. [92]
    An anti-leakage liquid metal thermal interface material - PMC - NIH
    May 18, 2020 · Among these issues, the most severe problem is the leakage of an LM, because it will short the circuit and cause instant failure of the device.
  93. [93]
    Arctic Silver 5
    Arctic Silver 5's conductive matrix, it will take a up to 200 hours and several thermal cycles to achieve maximum particle to particle thermal conduction.
  94. [94]
  95. [95]
    SPI-Modified h-BN Nanosheets-Based Thermal Interface Materials ...
    Jun 19, 2024 · TIMs are prepared using exfoliated hexagonal boron nitride nanosheets (h-BNNS) as a nanofiller, and they were functionalized by ecofriendly natural biopolymer ...
  96. [96]
    Advances in Silicone-Free Thermal Interface Materials - Trumonytechs
    Silicone-free TIMs are highly conductive, resilient, and have liquid metal/solid particle doping, stability, and are more environmentally friendly than ...Missing: computer | Show results with:computer<|separator|>
  97. [97]
    PC Airflow Guide: How to Set Up and Position Your Fans
    Sep 29, 2022 · Generally, the goal of positioning fans in a PC case is to create an airflow channel from the right side/front of your case to the upper left/ ...
  98. [98]
    Best PC Fan Setups | Cooler Master
    In this article, we are going to discuss how to maximize the cooling performance of your PC case.<|separator|>
  99. [99]
    What is positive air pressure? - Tech Talk∣SilverStone
    Chassis with positive air pressure can prevent dust from penetrating into the chassis by use of filters on intake fans and forcing air out of the chassis ...
  100. [100]
    Dust Prevention and Case Pressure: Does It Really Matter?
    Oct 12, 2020 · The positive pressure build has three intake fans and a single exhaust. Two intakes fans are located at the front of the case with the third at ...
  101. [101]
    The Importance of Cable Management | AORUS
    Jul 21, 2022 · The big reason you want to use as few cables as possible is that it helps increase the airflow within the computer as there is less resistance ...
  102. [102]
  103. [103]
    COUGAR Airface - Mid Tower Case
    The Airface has a perforated front panel for airflow, a 230mm wide design, supports E-ATX motherboards, 330mm GPUs, and has a quick slide dust filter.
  104. [104]
    Correcting case airflow and dust build up | TechPowerUp Forums
    Jul 11, 2024 · Positive pressure reduces the dust build up since air only goes in from the intake fans, which are usually designed with a filter.<|separator|>
  105. [105]
    Airflow Optimization in Computer Cases: A Study on Performance ...
    Utilizing Computational Fluid Dynamics (CFD) simulations, this research analyzes various fan placements and speeds to optimize airflow and cooling performance.
  106. [106]
    [PDF] ATX specification - Bitsavers.org
    ATX is an evolution of Baby-AT, improving ease-of-use, I/O, processor support, and cost. It combines LPX integration and Baby AT expandability.
  107. [107]
    O11 DYNAMIC MINI V2 - LIAN LI is a Leading Provider of PC Cases
    The slanted bottom design and pre-installed fans channel airflow directly to the GPU, enhancing cooling efficiency. In thermal testing under identical noise ...
  108. [108]
    Silent Storm Cooling AI for Next-Gen Gaming Desktops - MSI
    Apr 23, 2025 · Discover how MSI's Silent Storm Cooling AI combines AI fan control and compartmentalized airflow to reduce GPU and SSD temperatures, ...
  109. [109]
    Darcy-Weisbach Equation: Pressure & Head Loss in Pipes
    The Darcy-Weisbach equation can be used to calculate the major pressure and head loss due to friction in ducts, pipes or tubes.
  110. [110]
    Uniflair Rack Mounted Room Cooling | Schneider Electric USA
    Rack Mounted cooling solution to meet the specific needs of Micro Data Center and Edge computing solutions.
  111. [111]
    What Are Rear Door Heat Exchangers (RDHx)? - Supermicro
    Discover what a rear door heat exchanger (RDHx) is, how it works, and how it improves data center cooling efficiency by removing heat directly at the rack level
  112. [112]
    To cool datacenter servers, Microsoft turns to boiling liquid
    Apr 6, 2021 · Microsoft is the first cloud provider to run two-phase immersion cooling in a production environment. Photo by Gene Twedt for Microsoft.Missing: principles Novec
  113. [113]
    Hot Aisle Containment in Data Centers - SubZero Engineering
    Hot Aisle Containment can double the CRAC/CRAH cooling capacity. KEY BENEFITS OF HOT AISLE CONTAINMENT: Separates supply and return airflow which provides a ...
  114. [114]
    Uptime Institute Global Data Center Survey 2025
    Jul 29, 2025 · Average PUE levels show little change for the sixth consecutive year, with improvements constrained by legacy infrastructure and region-specific ...
  115. [115]
    [PDF] OLCF's Frontier Supercomputer - ATPESC
    • 29 MW Power Consumption. • 9,408 nodes. • 9.2 PiB memory (4.6 PiB HBM, 4.6 ... warm water cooling in Frontier (32 C). ORNL Data Center PUE= 1.03.
  116. [116]
    Water cooling returns to IBM mainframe - Computerworld
    Sep 1, 2010 · The new mainframe, dubbed the zEnterprise 196 , can operate with up to 96 processors versus 64 in the System z10 mainframe using about the same ...
  117. [117]
    DeepMind AI Reduces Google Data Center Cooling Energy 40%
    Jul 20, 2016 · By applying DeepMind's machine learning to our own Google data centers, we've managed to reduce the amount of energy we use for cooling by up to 40 percent.
  118. [118]
    Why Liquid Cooling Is the Future of Hyperscale Data Centers in 2025
    May 25, 2025 · In 2025, hyperscalers like Google, Meta, AWS, and Microsoft are rolling out liquid-cooled environments across their newest facilities.
  119. [119]
    Stockholm Data Parks sets new standards for sustainable data centers
    We seek to help large data centers maximize cost efficiency and sustainability with low cost renewable electricity and paid-for heat recovery.
  120. [120]
    Guide to Laptop Cooling Systems: Heatsinks, Vapor Chambers ...
    Nov 1, 2024 · 4. Heat Pipes · Evaporation: When the CPU or GPU heats up, the liquid inside the heat pipe evaporates, turning into vapor that absorbs the heat.Vapor Chambers · Heat Pipes · Fan Systems · Vent PlacementMissing: methods | Show results with:methods
  121. [121]
    What is a vapor chamber, and how does it improve my PC's cooling?
    Dec 2, 2022 · Vapor chambers may still use heat pipes to distribute thermal energy to the final heatsink, but they can use them much more efficiently since ...Missing: ultrabooks | Show results with:ultrabooks
  122. [122]
  123. [123]
    [Gaming NB] Intelligent Cooling | Official Support | ASUS Global
    Feb 27, 2022 · Every ROG machines have their cooling carefully tailored. The heat spreaders are specially shaped for each machine and placed to optimally ...
  124. [124]
    Lenovo Legion Pro 5i review (gen 8 - Core i9, RTX 4070)
    Rating 4.2 · Review by Derek SullivanIt's a good-value mid-tier laptop, well built, with a good screen and inputs, and plenty of performance.
  125. [125]
    Thermal Throttling in Smartphones: A Mere Problem? - Technolobe
    Apr 24, 2020 · Thermal throttling (or Dynamic Frequency Scaling) is an approach of scaling the frequency of CPU so as to conserve power and reduce the amount of heat ...
  126. [126]
    Ultra-thin M4 iPad Pro features new internal structure to improve ...
    May 12, 2024 · During the keynote, Apple said the iPad Pro has 20% improved thermal performance thanks to the addition of graphite sheets in the main housing ...
  127. [127]
    Early M4 iPad Pro Teardown Reveals Copper Apple Logo For Heat ...
    May 17, 2024 · Conjoined with the graphite sheet in the chassis, the copper-infused Apple logo will improve thermal performance by up to 20 percent. Apple was ...
  128. [128]
    This 1 Millimeter Chip Works As a Tiny Fan for a Phone's Processor
    Aug 20, 2024 · This 1 Millimeter Chip Works As a Tiny Fan for a Phone's Processor. xMEMS Labs is applying its micro audio speaker technology to device cooling.
  129. [129]
    Undervolting 2020 Dell Laptops like the Vostro 7500 and More Tips ...
    Sep 7, 2020 · Edit EFI Variables to Enable CPU Undervolting. The most effective way to reduce the heat and improve battery life is to undervolt the CPU.
  130. [130]
    Undervolting Your PC: What It Is and Why You Should Try It
    Jun 12, 2024 · Undervolting is a popular method for improving a laptop's operating temperatures and ensuring it does not become overheated or overburdened during use.
  131. [131]
    Passive cooling? : r/SteamDeck - Reddit
    Mar 16, 2022 · It's not unheard of for 15w processors to be passively cooled. I can see why Valve did not go this route as stock, but how likely do you think it would be for ...
  132. [132]
    Embedded Board Thermal Management Solutions | DigiKey
    Sep 5, 2024 · Networking Equipment (Routers, Switches):. Continuous Operation: Networking equipment often runs 24/7, leading to continuous heat generation.
  133. [133]
    Advanced Cooling Techniques for High-Power Telecommunications ...
    Jun 4, 2025 · A heat sink is a passive cooling device made of thermally conductive materials like aluminum or copper, designed to absorb and dissipate heat ...
  134. [134]
    Maximising Performance and Reliability of Automotive Electronics ...
    Nov 23, 2020 · Automobile electronics are usually required to work between -40°C and 125°C, with rapid transitions between the temperature extremes. The ...
  135. [135]
    Automotive Conformal Coatings: Silicone vs Parylene
    Sep 1, 2023 · Silicone cures rapidly and is a reliable dielectric barrier, displaying exceptional stability across a wide temperature range.
  136. [136]
  137. [137]
    [PDF] Scrooge Attack: Undervolting ARM Processors for Profit - arXiv
    Voltage scaling is an open loop system, in which the voltage of an integrated circuit is regulated (dynamically) based on an external setting. Increasing or ...
  138. [138]
    Dynamic Voltage and Frequency Scaling - Arm Developer
    A way in which software running on the ARM core can reliably modify the clock speed and supply voltage of the core, without causing problems in the system.Missing: undervolting | Show results with:undervolting
  139. [139]
    [PDF] Dynamic Undervolting to Improve Energy Efficiency on Multicore ...
    May 6, 2020 · We develop a model that takes as input selected CPU performance counters and core utilization, and estimates the voltage margin of the workload ...
  140. [140]
    The Unknown Tech Behind a New Generation of Edge AI Devices
    May 14, 2025 · The first piezoMEMS micro-cooling fan is 96 percent smaller and lighter than traditional fans – and is the only active thermal management device ...
  141. [141]
    Tiny cooling fan-on-a-chip designed for phones to be deployed in AI ...
    May 1, 2025 · Frore System has been working on its solid-state cooling chip since 2022, which uses piezoelectric vibrations to drive airflow, similar to xMEMS ...
  142. [142]
    Edge AI Meets Next-Gen Cooling: The Breakthrough of Silicon ...
    Mar 19, 2025 · MEMS-based miniature-fan technology can provide improved thermal performance, increased reliability, and reduced noise for advanced processors.
  143. [143]
    Nokia adds Liquid Cooling technology to latest AirScale Base ...
    Mar 1, 2022 · Nokia's liquid-cooled AirScale baseband solution can accommodate any liquid-cooled common or capacity plug-in unit and supports all radio access ...
  144. [144]
    Nokia see sustainability leap in world-first 5G liquid cooling ...
    Nokia today announced that its liquid cooling 5G AirScale Base Station solution has helped Finnish mobile operator, Elisa, reduce the potential energy expenses.
  145. [145]
    Microfluidic Interposer for High Performance Fluidic Chip Cooling
    An efficient cooling approach is crucial especially for high performance computing processors (HPC). As reference, the “International Technology Roadmap for ...
  146. [146]
    3D Integrated Circuit Cooling with Microfluidics - PMC
    Jun 7, 2018 · This paper presents an analysis of all publications available about the microfluidic cooling technologies used in 3D IC thermal management.
  147. [147]
    Dynamic Undervolting to Improve Energy Efficiency on Multicore ...
    Voltage scaling can effectively reduce processor power, but also reduces the reliability of the SRAM cells in on-chip memories. Therefore, it is often ...