VU meter

A VU meter, short for Volume Unit meter, is a standardized electromechanical or digital device used in to measure and display the average level of an in volume units (VU), providing an approximation of perceived rather than precise or values. The VU meter originated in the late 1930s as a collaborative effort between Bell Telephone Laboratories, , and to establish a uniform method for indicating signal levels in broadcast and telephone systems, with its initial specification published in and formalized as the Standard Volume Indicator (SVI) in 1942 under ANSI C16.5. This standard, later adopted internationally as IEC 60268-17 in 1990, defined the meter's response characteristics to ensure consistency across professional audio applications, including and recording studios. In design, a traditional VU meter features a moving-coil needle driven by a full-wave that converts the to , combined with an attenuator network for , resulting in a characteristic 300-millisecond rise and fall time that emphasizes sustained signal energy over transients. The scale typically ranges from -20 to +3 VU, with 0 VU calibrated to +4 dBu for a 1 kHz , representing the reference operating level in systems (equivalent to +4 dBm in 600-ohm impedance standards). Modern digital implementations simulate this behavior in software, often aligning 0 VU to -18 in workstations for headroom management. VU meters remain essential in audio engineering for gain staging during mixing and mastering, as their quasi-RMS response helps engineers maintain consistent perceived and avoid while providing visual on average levels, though they are less suited for capturing fast peaks compared to peak program meters. Their intuitive needle movement and correlation with human hearing make them a staple in professional consoles, vintage gear recreations, and even high-end consumer audio systems for monitoring .

Overview

Definition and Purpose

A volume unit (VU) meter, also known as a standard volume indicator (SVI), is a device that displays a representation of the signal level in , specifically measuring the average power level of electrical program signals calibrated to approximate the perceived by the human ear rather than instantaneous voltage. The meter uses a scale in volume units (VU) and operates as a passive electromechanical , typically employing a d'Arsonval movement with a to convert audio signals into a reading that reflects sustained energy rather than transients. The primary purpose of the VU meter is to provide consistent readings of dynamically changing audio programs across various instruments and equipment, enabling audio to and signal levels effectively in professional settings. In , recording, and mixing applications, it helps ensure uniform signal levels to prevent , maintain adequate headroom, and support creative decisions by emphasizing average signal energy over peaks, thus aligning with how listeners perceive overall volume. A key distinction from a standard lies in the VU meter's design, which integrates the signal over time via its standardized dynamic response to mimic auditory , rather than providing a direct of voltage . Developed in the mid-20th century for analog audio systems in and radio, it standardized level measurements to facilitate in early broadcast and communication technologies.

Basic Operation

A VU meter typically consists of a moving-coil meter movement equipped with a needle indicator, which is driven by a rectifier circuit that converts the incoming alternating current (AC) audio signal into direct current (DC) to produce needle deflection. The mechanical assembly includes a damped coil suspended in a magnetic field, ensuring smooth and controlled movement of the needle in response to the rectified signal. In terms of , the audio input is fed through a full-wave , often using copper-oxide or diodes, followed by a that averages the rectified , resulting in a quasi-root-mean-square () reading that emphasizes sustained volume levels rather than instantaneous peaks. This process provides an approximation of perceived by integrating the signal over a short period, allowing the meter to reflect the overall energy of the audio program material. The scale on a VU meter features a damped needle that traverses a logarithmic marking from -20 VU to +3 VU, with 0 VU serving as the reference level calibrated to a specific input voltage, such as 1.228 volts at 1 kHz for professional applications. The needle's analog movement offers an intuitive, eye-friendly visual representation of level changes, enabling audio engineers to assess and balance signals in real time without digital harshness. This smooth deflection facilitates quick judgments on program density and headroom during mixing and broadcasting.

Technical Specifications

Calibration and Reference Level

The reference level for a VU meter is defined such that 0 VU corresponds to +4 , equivalent to 1.228 volts , when measured across a 600-ohm load using a 1,000 Hz test tone. This ensures consistent signal levels across equipment, aligning with the meter's purpose of monitoring average program levels to prevent while maintaining headroom. The calibration procedure requires applying a 1,000 Hz sine wave at the reference level of +4 dBu (1.228 volts RMS) to the meter's input, adjusting the associated trim potentiometer or attenuator until the needle precisely aligns with the 0 VU mark on the scale. For accurate setup, particularly in legacy or high-impedance systems, a bridged-T attenuator network is incorporated in the input circuit to match the 7,500-ohm impedance specification while minimizing loading effects on the source signal. This network typically consists of precision resistors configured to provide balanced attenuation without altering the meter's dynamic response. The VU reading itself is calculated using the formula: \text{VU reading} = 20 \log_{10} \left( \frac{V_{\text{rms}}}{V_{\text{ref}}} \right) where V_{\text{rms}} is the measured root-mean-square voltage of the input signal, and V_{\text{ref}} is the reference voltage. In professional applications, this is standardized to +4 (1.228 V), ensuring in broadcast and studio environments. However, consumer-grade equipment may calibrate 0 VU to -10 dBV (approximately 0.316 volts RMS), with V_{\text{ref}} = 0.775 V adjusted accordingly for compatibility, though professional standards prioritize +4 to avoid level mismatches.

Ballistics and Rise Time

The of a VU meter describe its temporal response, characterized by the and of the moving-coil mechanism, which simulates the human ear's integration of over time rather than capturing instantaneous peaks. This design provides a smoothed indication of average signal levels, reflecting perceived through deliberate needle sluggishness. The is defined as the duration for the needle to reach 99% of a steady 0 level when a 1,000 Hz tone at 0 is suddenly applied, specified at 300 ±10% milliseconds per the C16.5-1942 standard. This response incorporates an overshoot of 1-1.5% for steady sinusoidal signals and 2-3% for transient signals, ensuring the meter does not react excessively to brief changes while maintaining responsiveness. The fall time mirrors the rise time at approximately 300 ms, yielding a symmetrical ballistic curve for both increasing and decreasing signal envelopes. Mathematically, the meter's behavior approximates a RC low-pass filter with \tau \approx 300 ms, where the output voltage V(t) follows V(t) = V_s (1 - e^{-t/\tau}) for a step input V_s, enabling effective tracking of signal average power.

Frequency Response

The frequency response of a VU meter is designed to provide accurate indication of signal levels across the audible frequency spectrum, ensuring that the meter's reading remains consistent regardless of the input signal's frequency within specified tolerances. According to the standard specifications, at the 0 VU reference level, the meter's indication should not deviate from the reading at 1 kHz by more than ±0.2 dB over the range of 35 Hz to 10 kHz, with the tolerance extending to ±0.5 dB from 25 Hz to 16 kHz. These tolerances reflect the meter's intent to measure perceived loudness in the primary audio band without undue influence from frequency variations. The circuit design of the VU meter, particularly the full-wave rectifier followed by a low-pass filter network, plays a in achieving this flat response within the audible range. The converts the AC input signal to a pulsating DC, while the integrates the signal to mimic the ear's averaging response, maintaining near-flat characteristics from low to mid-high frequencies. Outside the audible band, the design incorporates inherent to attenuate and ultrasonic components, preventing the meter from responding to irrelevant noise such as or high-frequency artifacts. To verify compliance with these specifications, the is tested by applying sine waves swept across the relevant range at the 0 reference level (typically +4 at 1 kHz), while monitoring the meter's deflection to confirm alignment with its quasi-logarithmic scale. This method ensures that the meter's output remains stable and representative of the input power across the band. Despite these design goals, original VU meter implementations exhibit slight deviations at frequency extremes, primarily due to the coupling used for balanced input isolation, which can introduce minor low- or shifts beyond the core tolerances.

Electrical Characteristics

The electrical characteristics of a VU meter are defined to ensure seamless integration into audio systems while maintaining and standardized performance. The is standardized at 7,500 ohms, which can be configured as balanced or unbalanced to minimize loading effects on the connected audio lines. This value, typically achieved through a combination of series and shunt resistors, allows the meter to circuits without introducing significant or . The core circuit employs a full-wave copper-oxide for detection, converting the into a suitable for the meter's , ensuring accurate averaging of the signal . In series with the meter coil, a 3.9 kΩ provides essential to control the needle's response and prevent excessive oscillations, aligning with the ballistic specifications for . This configuration isolates the from the audio line while preserving the overall impedance. Power for the VU meter is derived passively from the rectified itself, eliminating the need for an external supply in standard implementations, though some designs incorporate a low-current external DC source to drive the meter coil to its full-scale deflection of 200 μA. This self-powered approach suits environments where reliability and minimal additional components are prioritized. Originally engineered for 600-ohm balanced lines common in mid-20th-century and , the VU meter's electrical design bridges modern low-impedance sources (such as 150-ohm or unbalanced consumer lines) with negligible loss, provided the is maintained. This versatility supports its enduring use across analog audio infrastructures without requiring impedance-matching transformers in most cases.

Development and Standardization

Origins

The VU meter, originally known as the Standard Volume Indicator (SVI), emerged from a collaborative effort to standardize audio level measurements in the burgeoning fields of and . In early , engineers from the (), (), and Bell Telephone Laboratories initiated a joint project to address the inconsistencies plaguing existing volume measurement tools, which hindered reliable across networks. This development was driven by the need for a practical that could approximate the perceived of program material, rather than merely registering electrical voltage or amplitudes. Prior to the SVI, audio engineering faced significant challenges due to the absence of uniform metering standards. Early systems relied on disparate devices such as lightspot galvanometers, which provided rapid but imprecise readings unsuitable for complex program audio, and simple voltmeters, which failed to correlate with actual or transmission quality. These inconsistencies often resulted in of AM radio signals, causing and inefficient use of transmission lines, as well as variable performance in circuits where levels needed to remain consistent for clear communication. The first rudimentary volume indicator had appeared in 1921 for a public-address system during the Unknown Soldier burial ceremonies, aimed at preventing overload, but it lacked the required for widespread adoption in . By the late 1930s, the rapid growth of network radio amplified these issues, prompting broadcasters to seek a unified approach to ensure compatibility and . The core development team included H. A. Chinn from , D. K. Gannett and Iden Kerney from Bell Laboratories, and R. M. Morris from , with additional contributions from Robert A. Bradley (), George M. Nixon (), and S. Brand (Bell Laboratories). Their work focused on designing a meter that bridged across transmission lines without significant loading, using a mechanical movement coupled with rectifiers to mimic human hearing response. Initial prototypes, incorporating copper-oxide rectifiers for signal rectification, were rigorously tested in 1939 on amplifiers to evaluate ballistic characteristics and thresholds. These tests confirmed the meter's ability to reach 99% deflection in approximately 0.3 seconds for steady tones, providing a reliable indicator of average program levels. By May 1939, the SVI had been adopted as an industry standard, marking a pivotal advancement in audio metering that facilitated consistent control for radio transmission lines.

Standardization Process

The VU meter was formally standardized in 1942 by the (ASA, predecessor to the or ANSI) as ASA C16.5-1942, titled "American Recommended Practice: Volume Measurements of Electrical Speech and Program Waves." This standard emerged from collaborative efforts by a joint subcommittee of the and the National Association of Radio and Television Broadcasters, focusing on consistent measurement for installations and to ensure across equipment. The specification defined key characteristics, including a reference level where a 1 kHz at +4 dBm (1 mW into 600 Ω) produces a 0 VU reading, with tolerances for meter ballistics and . Subsequent revisions refined these parameters to address practical implementation issues. In 1954, the standard was updated as ASA C16.5-1954, clarifying impedance requirements (e.g., a recommended 300 Ω source) and calibration procedures while maintaining core electrical and dynamic attributes; it was reaffirmed in 1961. These updates stemmed from ongoing feedback, including contributions from manufacturers through bodies like the Electronic Industries Association (EIA), to improve manufacturing consistency and reduce variations in meter response. By the late , the standard had evolved to emphasize tighter tolerances on (300 ms ±10% for 99% deflection) and input circuitry, ensuring reliable volume indication in chains. Internationally, the VU meter's principles influenced global audio standards, notably through incorporation into IEC 60268-17 (first edition, 1990), which specified electromechanical volume indicators with similar ballistics and a 7500 Ω ±3% input resistance for equipment. In the , neon bar-graph variants adapted the VU scale for consumer high-fidelity systems, offering visual appeal and durability while approximating traditional needle dynamics through segmented glow-transfer displays. By the 1980s, VU meters were standardly integrated into broadcast consoles, such as those from Broadcast Electronics and , providing essential monitoring for program levels in radio and television production. Despite its widespread adoption, the VU meter faced critiques for its slow response to transients, leading the BBC to dub it the "Virtually Useless" meter and favor peak program meters (PPMs) for overshoot detection. Nevertheless, the persisted due to its utility in gauging average and facilitating , influencing hybrid analog-digital systems and remaining a in audio .

Usage in Audio Production

Analog Applications

In analog broadcasting and recording, VU meters serve as essential tools for monitoring average signal levels on mixers, tape machines, and transmitters. They were specifically designed to ensure consistent audio levels in radio transmission, where 0 VU corresponds to 100% modulation on AM carriers to prevent overmodulation and distortion. In studio recording workflows, engineers typically aim for 0 VU on vocal tracks to capture clear, balanced signals onto analog tape, while allowing transient peaks to reach +3 VU to maximize headroom without saturating the medium. This approach optimizes dynamic range and minimizes noise, as the meter's average response aligns closely with perceived loudness in speech and music. VU meters play a critical role in gain staging within analog environments, guiding adjustments to input gains and to keep signals centered around 0 , thereby avoiding overload while maintaining natural dynamics. Calibrated to professional line levels such as +4 , they help engineers align steady test tones (e.g., 1 kHz sine waves) across the signal path, ensuring consistent volume transfer from through consoles to or transmitters. This practice is particularly vital in mastering and AM/ preparation, where precise level control prevents groove overload or modulation issues, preserving audio fidelity in the final output. By focusing on average energy rather than instantaneous peaks, VU metering promotes a balanced mix that translates well across analog media. In professional analog console setups, such as those from Neve and , VU meters are seamlessly integrated alongside patch bays to deliver real-time visual feedback during live mixing and . These meters, often backlit and positioned centrally on the console, allow operators to monitor channel outputs and buses intuitively, facilitating quick adjustments in dynamic sessions like orchestral or recordings. Paired with the console's discrete circuitry, they provide a reliable indication of overall program level, enabling engineers to route signals via patch bays without unexpected level shifts. This integration enhances workflow efficiency in traditional studios, where tactile control and immediate metering are paramount. Despite their strengths, VU meters have practical limitations in analog applications, particularly their slow ballistics, which can fail to register brief transients that lead to clipping on tape or in amplifiers. With a rise time of about 300 ms, they underread short peaks by 10-20 dB, potentially allowing distortion to occur unnoticed during percussive or impulsive sounds. As a result, engineers often supplement them with faster peak program indicators to catch these events, ensuring comprehensive level management. The meter's design, while aiding dynamic control through its ear-like response, underscores the need for hybrid monitoring in high-fidelity analog production.

Digital and Modern Implementations

In digital audio workstations (DAWs) such as Pro Tools and Logic Pro, software plugins emulate the analog ballistics of traditional VU meters to facilitate precise gain staging and hybrid analog-digital workflows. These plugins, including the Waves VU Meter, replicate the classic metering response with a 300 ms integration time and smooth needle movement, allowing engineers to monitor average signal levels and maintain headroom during mixing and tracking. Free alternatives like the TBProAudio mvMeter2 provide similar functionality as a VST/AU/AAX plugin, offering VU mode alongside other metering options to ensure compatibility with modern production pipelines. Contemporary hardware VU meters revive analog aesthetics while adapting to digital environments through interfaces like AD/DA converters. Manufacturers such as Crookwood produce rack-mountable units with precision Sifam meters and built-in stepped attenuators, enabling accurate to digital line levels (e.g., +4 ) for integration with digital consoles or DAW outputs. These devices connect via balanced analog inputs, often paired with digital-to-analog conversion for retro visual feedback in professional studios. VU metering integrates with modern loudness standards like EBU R128 and ATSC A/85 as a supplementary tool for assessing , though it is not the primary metric for integrated (measured in ). Plugins such as the HoRNet VU Meter MK4 combine VU ballistics with EBU R128-compliant measurements, allowing simultaneous monitoring of average levels and program to meet broadcast requirements. Similarly, the mvMeter2 supports both VU and EBUR128 modes, aiding compliance with ATSC A/85's -24 LKFS target by providing contextual average level insights during normalization. As of November 2025, VU meters remain relevant in streaming audio production, where mixes target -14 for platforms like while using VU readings to preserve headroom and dynamics, typically aiming for average levels around 0 VU with peaks reaching +3 VU to avoid over-compression. In consumer hi-fi systems, and LED-based VU variants, such as the Douk Audio VU9, offer retro-styled displays with real-time spectrum visualization, enhancing aesthetic appeal in setups without altering signal paths.

Alternative Metering Systems

Peak Program Meters

Peak programme meters (PPMs), also known as quasi-peak programme meters, are specialized audio level indicators designed to measure the peak amplitudes of programme signals in professional audio environments. Originally developed by the British Broadcasting Corporation (BBC) and later standardized by the European Broadcasting Union (EBU) under specifications such as EBU Tech 3205 and IEC 60268-10, PPMs provide a faster response to signal transients compared to volume unit (VU) meters. These meters employ quasi-peak detection, which integrates the signal over a short period to approximate audible peaks while ignoring ultra-short transients that do not contribute significantly to perceived loudness or system overload. The ballistics of PPMs are optimized for rapid peak capture, with an attack or rise time of 5-10 ms to reach 4 dB below the final steady-state value for a step input, enabling detection of transients lasting as short as 5 ms. For a 20 dB step change, the full rise time extends slightly longer due to the meter mechanics, but the initial response remains swift to prioritize overmodulation prevention. The fallback or decay time is slower, typically 1.5-2.5 seconds for a 20 dB drop, providing a hold function that allows operators to observe sustained peaks without the needle dropping too quickly. The scale is logarithmic in decibels relative to the alignment or line-up level, where 0 dB corresponds to 0 dBu (the reference alignment level), with the BBC variant using numbered marks from 1 to 7 spaced at 4 dB intervals—mark 4 indicating alignment and mark 6 representing the permitted maximum level of +8 dBu. In applications, PPMs are widely preferred in broadcast workflows to safeguard against in transmission systems, where levels must not exceed specified thresholds to avoid in radio or digital streams. They are commonly integrated into transmitters, mixing consoles, and modern workstations (DAWs) for real-time and , ensuring with standards like EBU R68 for in . Unlike the slower VU meter, which has a 300 ms suited for average programme , PPMs effectively capture transients that VU meters overlook, thereby minimizing clipping risks in and delivery where headroom is limited to 9-12 above . This quasi-peak response aligns closely with of programme dynamics while providing practical control for broadcast quality.

RMS and True Peak Meters

RMS metering quantifies the average power of an audio signal by calculating the root mean square (RMS) voltage, offering a response that correlates more directly with perceived loudness than peak-based methods, akin to VU metering but omitting the analog-style ballistic needle simulation for faster, more precise digital readouts. The RMS value is computed using the formula \text{RMS} = \sqrt{\frac{1}{T} \int_0^T v(t)^2 \, dt}, where v(t) represents the instantaneous signal voltage over an integration period T, typically 300–400 ms for audio applications. This power-averaged approach avoids the slower attack and decay of VU meters, enabling better level management in real-time digital workflows. In practice, digital RMS meters are calibrated to align with VU standards, where 0 VU equates to approximately -18 dBFS for sine waves, a convention adopted in software tools like to bridge analog heritage with modern production. This calibration ensures consistent referencing across hybrid analog-digital setups, with integration often incorporating frequency weighting (e.g., K-weighting in contexts) to better match human hearing sensitivity. True peak metering enhances accuracy beyond sample-peak detection by employing 4x —interpolating the signal to four times the original sample rate (e.g., 44.1 kHz to 176.4 kHz)—followed by a to reveal inter-sample peaks that standard meters miss. These hidden peaks, arising from sinc interpolation in digital-to-analog conversion, can exceed sampled values by up to 3 , particularly for high-frequency content near Nyquist. Such metering is vital for dithered audio exports, where added noise shapes can amplify reconstruction artifacts, potentially causing clipping in playback devices or lossy codecs. The BS.1770 standard incorporates both RMS-based estimation (via gated mean-square integration) and true algorithms to standardize measurements across broadcast and streaming, directly addressing the loudness wars by enforcing normalized levels like -23 for integrated program loudness. These tools excel in digital ecosystems by preventing overshoot in non-linear processing chains, ensuring compliance for platforms like or , and overcoming VU meter's analog-era shortcomings in handling inter-sample dynamics and perceptual weighting.

References

  1. [1]
    VU Meters: “Virtually Useless” or Very Useful? - Sound On Sound
    The VU meter was conceived in 1939, through a collaboration between research company Bell Labs and the American broadcasters CBS and NBC, and a paper they ...
  2. [2]
    Glossary definition of 'VU Meter' - Prism Sound
    A meter designed originally to measure and standardise the levels in telephone lines. It is defined in ANSI C16.5-1942, British Standard BS 6840, and IEC 60268- ...
  3. [3]
    Learn More: Peak Metering - Audio Engineering Society
    VU Meter with D'Arsonval (Moving Coil) Movement. An official VU meter has a mechanical pointer powered directly from the audio line it measures. The ...
  4. [4]
    Understanding VU Meters
    ### Key Facts About VU Meters
  5. [5]
    VU Metering - SoundBridge
    Dec 24, 2023 · What Is a VU Meter? The VU meter shows an averaged signal level and gives an impression of perceived loudness. The origins of the mentioned ...<|control11|><|separator|>
  6. [6]
    [PDF] Some Questions and Answers on the Standard Volume Indicator ...
    Jul 27, 2006 · Program levels in the USA are usually read with a “Standard Volume Indicator” (SVI)1, popularly called a “vu meter”. Development of the SVI ...
  7. [7]
    VU Meters Selection Guide - GlobalSpec
    VU meters measure the volume (intensity) of analog audio signals. They display signal levels in volume units (VU), a measure of average volume level.
  8. [8]
  9. [9]
    Practical VU Meter Circuits - Michael Fidler, Classic Audio Ltd
    VU, or Volume Unit, meters are a way of measuring the level of an audio signal. They measure the an average of the signal they are presented with, not the peak ...
  10. [10]
    Analog VU Meters & Quick Pointers - EDN Network
    Mar 23, 2024 · The behaviour of the VU meter, designed originally to measure and standardise the levels in telephone lines, is defined in ANSI C16.5-1942, ...
  11. [11]
    A model of the VU (volume-unit) meter, with speech applications
    Jan 1, 2007 · The ideal VU meter is a full wave rectifier followed by a second order low-pass system. The VU meter level is reported in dB vu referenced ...
  12. [12]
    Meter Madness: What Your Level Meters Tell You And What They ...
    The traditional VU meter is mechanical, analog, and has a standardized (even the color scheme is standard), logarithmic (decibel) scale that runs from –20 to +3 ...Missing: markings | Show results with:markings
  13. [13]
    Meter Reader (ES May 84)
    The crucial specification to look for is the ANSI standard C16.5-R, the characteristics of which are listed below: 1. Full wave rectification must be used ...
  14. [14]
    How to calibrate a VU meter? - Shure Service And Repair
    Sep 1, 2021 · A VU meter can be calibrated to any reference level desired. In the United States, the most common reference level is 0VU = +4dBm.
  15. [15]
    VU Meter Questions | GroupDIY Audio Forum
    Jun 8, 2004 · No, you can make a meter faster by over-driving it. But eliminating overshoot (true VU allows only about 3% overshoot) is nearly impossible ...How do you find VU meter specs? - GroupDIY Audio ForumAd VU meter api 312 | GroupDIY Audio ForumMore results from groupdiy.com
  16. [16]
    VU Meter : Circuit Diagram, Working, Characteristics and Its ...
    A VU meter is a simple voltmeter that uses a simple signal and displays it through 300 ms of an attack & release time.
  17. [17]
    On The Level: Audio Metering Then & Now - ProSoundWeb
    May 6, 2025 · To help guarantee a consistent frequency response, that level reading was not allowed to differ by more than 0.2 dB between 35 Hz to 10 kHz and ...
  18. [18]
    Tutorial on Audio Levels | Collinsradio - Collins Collectors Association
    ... 0.2 dB between 35 and 10 kHz and not more than 0.5 dB between 25 and 16 kHz. Sensitivity Applying a sinusoidal potential of 1.228V (4 dB above 1 mW into a ...
  19. [19]
    Voltage Transmission For Audio Systems - Richard Hess
    High frequency resonances are adequately damped. 2. Frequency-amplitude ... 3.9k ohm resistance isolating the VU meter rectifiers from the audio line.
  20. [20]
    [PDF] A New Standard Volume Indicator and Reference Level
    Aug 21, 2006 · Impedance. The impedance of the volume indicator arranged for bridging across a line is about 7500 ohms when measured with a sinusoidal voltage ...
  21. [21]
    [PDF] Bewildering Wilderness - RANE Commercial
    The VU meter was created in the. 1940s for the movie industry and standard- ized by the American Standards Associa- tion as ASA C16.5-1942 (another of those.Missing: input | Show results with:input<|control11|><|separator|>
  22. [22]
    Level Practices (Part 1) - Digido.com
    Apr 6, 2017 · In the days of analog tape, a 0 VU reference of +4 dBv with a clipping point of +20 dBv provided reasonable amplifier headroom, because musical ...
  23. [23]
    8424 - AMS | Neve
    All 24 channels use 8-stage post-insert LED metering, ideal for metering all incoming signals and the large, backlit VU meters mounted in the centre of the ...
  24. [24]
    VU Meter Plugin - Waves Audio
    In stock Rating 4.7 (361) · Free deliveryMix and track in your DAW using the industry's classic metering method, in order to help you achieve optimal levels, sufficient headroom and a clearer mix.
  25. [25]
    mvMeter2 - TBProAudio
    mvMeter is a multivariable meter including RMS, EBUR128, VU and PPM measurement. mvMeter2 is the successor of mvMeter and adds single/dual meter display.
  26. [26]
    VU Meters - Crookwood
    Crookwood make 3 types of VU meters, each with a stepped attenuator so you can get the VU to work properly with modern digital level signals.Missing: hardware interface
  27. [27]
  28. [28]
    HoRNet VU Meter MK4
    The HoRNet VU Meter MK4 is a digital VU meter plugin with automatic gain, grouping, 300ms integration, and 300ms attack/release time.
  29. [29]
    Douk Audio VU9MINI RGB LED Tube Sound Level Meter Music ...
    In stock Rating 4.3 17 · Free deliveryCapture Real-time Music with Built-in Microphone · Effortless Installation Magnetic with Tube Design · 8 Dynamic Display Modes · Immersive Layer of Light · Perfect ...Missing: consumer hi- fi
  30. [30]
    [PDF] tech3205.pdf - EBU tech
    The integration time in normal mode shall be 10 ±2 ms. LEGACY TEXT. Page 10. Peak Programme Meter. EBU Tech. 3205-E.Missing: rise | Show results with:rise
  31. [31]
    404 - File or directory not found.
    Insufficient relevant content. The requested URL (https://www.itu.int/dms_pub/itu-r/opb/rep/R-REP-BS.2054-4-2014-PDF-E!!PDF-E.pdf) returns a "404 - File or directory not found" error, indicating the document is unavailable. No information on Peak Programme Meter (PPM) definition, ballistics, standardization, scale, applications, or comparisons to VU meters can be extracted.
  32. [32]
    Q. What's the difference between PPM and VU meters?
    In short, the VU meter shows an averaged signal level and gives an impression of perceived loudness, while a PPM indicates something closer to the peak ...
  33. [33]
    [PDF] BBC Research & Development White Paper WHP202
    Historically measured with a mechanical meter with controlled rise and fall times, such as the well-known “PPM”. Now done in software for digital applications.
  34. [34]
    Understanding Advanced Metering In Pro Tools | Production Expert
    Jul 17, 2023 · PPM EBU is identical to the British PPM (BBC) except for the meter scale. It is a variant of the British PPM designed for the control of ...
  35. [35]
    [PDF] R68-2000 Alignment level in digital audio production equipment
    - that, due to the characteristics of quasi-peak programme meters used by broadcasters, the true programme peaks can be 3 dB greater than those indicated ...
  36. [36]
    None
    ### Summary of ITU-R BS.1770-5 on True-Peak and RMS Integration
  37. [37]
    Limiter Features: Understanding True Peak Metering and Dithering
    Even when using limiting as a safeguard, so called inter-sample peaks can occur after digital-to-analog conversion (DAC) or when converting to lossy formats ...
  38. [38]
    The End Of The Loudness War?
    The bulk of BS1770-3 is concerned with defining a reliable, objective measurement of the subjective loudness of a piece of audio material, such as a TV ...