Fact-checked by Grok 2 weeks ago

Internal standard

An internal standard is a compound added to a sample in a known concentration to facilitate the qualitative identification and/or quantitative determination of the sample components in . This technique enhances the of measurements by compensating for variations in , instrument response, and procedural losses that could affect the signal. Typically, the internal standard is chemically similar to the , such as a or stable isotope-labeled version, ensuring it behaves comparably during the analytical process. In practice, the ratio of the signal to the internal standard signal is used for , rather than absolute signals, which minimizes matrix effects and improves reproducibility across samples. The method is widely applied in techniques like and , where it is essential for reliable quantification in complex matrices such as biological fluids, environmental samples, or pharmaceutical formulations. For instance, in liquid chromatography-mass spectrometry (LC-MS), stable isotope-labeled internal standards are preferred because they co-elute with the and experience identical conditions, reducing errors from suppression or enhancement. Selection of an appropriate internal standard involves ensuring it does not interfere with the peak, is stable under conditions, and is available in pure form at known concentrations. This approach contrasts with external standards, where calibration relies solely on separate reference solutions, making internal standards particularly valuable for trace-level analyses requiring high .

Fundamentals

Definition

In , an internal standard is defined as a known amount of a , distinct from the of interest, that is added in a fixed concentration to all samples, blanks, and standards prior to . This addition compensates for variability introduced during , instrument response fluctuations, or procedural losses, ensuring more reliable quantification. The internal standard (IS) must closely mimic the chemical and physical behavior of the throughout the analytical process, including extraction, derivatization, and detection, while producing a distinct, non-overlapping signal that does not interfere with the analyte's measurement. Key characteristics of an effective IS include to the —such as belonging to the same compound class or sharing functional groups—to ensure parallel responses to effects or conditions, yet it must be readily distinguishable, often through (e.g., or variants) or as a . Quantification using an internal standard relies on measuring the of the 's signal to that of the IS, which normalizes for inconsistencies across the analytical run and improves accuracy in complex . This approach is particularly valuable in techniques like and , where signal variability can otherwise compromise results.

Purpose and Advantages

The primary purpose of an internal standard in is to compensate for systematic and random variations that can affect the measurement of an , such as fluctuations in response, matrix interferences from the sample, losses during preparation steps like or , and inaccuracies in injection volumes. By adding a known quantity of a non-interfering compound to both samples and standards, the internal standard experiences the same analytical conditions as the , allowing the of their signals to normalize these errors and provide a more reliable quantification. This approach is particularly valuable in techniques like and , where uncontrolled variables can otherwise lead to significant deviations in results. The advantages of using internal standards include enhanced , often demonstrated by reduced relative standard deviation in replicate analyses, and improved accuracy, especially in complex matrices where external factors like or might otherwise suppress or enhance signals. For instance, in multi-step sample preparations, the corrects for incomplete recoveries or volumetric inconsistencies, leading to more consistent data without requiring perfect control over every procedural variable. Additionally, internal standards enable the analysis of smaller sample volumes—common in biological or environmental testing—while maintaining reliability, as the normalization accounts for potential losses that would be amplified in low-volume scenarios. In trace analysis, this can contribute to better limits of detection by mitigating noise from variability rather than solely relying on . While effective at addressing common sources of error, internal standards are not a and cannot compensate for fundamentally flawed experimental designs, such as inadequate separation or detector ; their benefits are maximized when properly selected to mimic the analyte's behavior. Overall, this technique promotes robustness in quantitative methods, reducing the impact of procedural uncertainties and supporting higher-throughput analyses in diverse fields.

Comparison to Other Methods

External Standard Method

The external standard method is a calibration technique in where a is constructed using one or more standards, each containing a known concentration of the pure , prepared and analyzed separately from the samples. These external standards allow for direct measurement of the instrument's response, such as or peak area, to the analyte, enabling quantification of unknown samples by without incorporating any additives into the sample matrix itself. The procedure begins with the preparation of a series of standard solutions containing varying, known concentrations of the analyte, typically spanning the expected range of sample concentrations. These standards are then analyzed under identical instrumental conditions as the samples to record their responses, after which a calibration curve is plotted with response on the y-axis and concentration on the x-axis, often using linear regression for the relationship. For sample quantification, the instrument response from the unknown is measured and its concentration determined by locating the corresponding point on the calibration curve. This approach is efficient for processing multiple samples, as a single calibration curve can serve numerous analyses. One key advantage of the external is its simplicity, requiring no addition of compounds to the samples, which avoids potential and streamlines preparation. It also permits the reuse of standards for ongoing checks, reducing overall preparation time for large sample sets. However, the is vulnerable to effects, where differences between the simple of the standards and the of the samples can introduce proportional errors in quantification. Additionally, it does not compensate for losses or variations occurring during sample pretreatment, such as or incomplete , potentially compromising accuracy in analyses. As an alternative, the internal can be employed to correct for such variability by adding a known compound to both standards and samples.

Standard Addition Method

The standard addition method is a calibration technique in used to quantify the concentration of an in a complex sample by adding known amounts of the analyte directly to aliquots of the sample itself. This approach creates a that is inherently matched to the sample's matrix, thereby minimizing errors from matrix interferences that could alter the analytical signal. Unlike external , it does not require a blank or matrix, making it particularly suitable for samples where such references are unavailable or impractical. The procedure typically involves preparing multiple aliquots of the sample and spiking them with increasing concentrations of the analyte standard, often in equal increments, while maintaining a constant sample volume. Each spiked aliquot is then analyzed using the chosen instrumental technique, such as or , to measure the corresponding signals. A calibration plot is constructed by graphing the signal against the added analyte concentration, and the line is extrapolated back to the point where the signal would be zero (the x-intercept), which corresponds to the negative of the original analyte concentration in the sample. For optimal results, the added concentrations should span at least five times the expected analyte level to ensure and , though care must be taken not to exceed the linear range of the method. One key advantage of the method is its ability to directly compensate for effects, such as signal suppression or enhancement caused by sample components, leading to more accurate quantification in heterogeneous like biological tissues or environmental samples. It is especially valuable when pure standards are scarce or when the is unique, as in forensic applications, and can sometimes offer precision comparable to or better than external standards when the concentration is sufficiently above the . Additionally, it may be briefly combined with an internal standard to further mitigate instrument variability. However, the method is more labor-intensive than simpler calibrations, requiring multiple sample preparations and analyses, and it can introduce non-linearity if spikes are too high relative to the original concentration. Precision may also degrade in low-concentration scenarios, and it does not inherently address all types of interferences, such as those shifting the independently of slope.

Historical Development

Origins in Early Analytical Techniques

The concept of the internal standard emerged in the late as analytical chemists sought to address variability in early instrumental measurements, particularly in . An early precursor was the method introduced in 1877 by French physicist Louis Georges Gouy in . Gouy added a known quantity of the to the sample to verify the constancy of within the flame, thereby correcting for fluctuations in and optical conditions that could affect . This approach laid groundwork for later internal techniques. By the 1920s, the internal standard method had evolved significantly through advancements in emission spectrometry, driven by the need to mitigate source instabilities and detection inconsistencies. Pioneering work by German spectroscopist Walter Gerlach and his collaborator Ernst Schweitzer demonstrated the utility of internal standards in arc and spark . They employed "homologous line pairs"—lines from the and a chemically similar —and "fixation pairs" to compensate for variations in the source, as well as adjustments for sensitivity in spectral recording. Their systematic exploration, detailed in the 1929 monograph Foundations and Methods of , established internal standards as a core strategy for reliable quantitative , influencing subsequent developments. However, the distinct internal standard technique, involving a non-analyte reference for matrix correction, originated and proliferated within the spectroscopic domain.

Key Advancements in the 20th Century

In the mid-20th century, internal standards gained prominence with the rise of instrumental analytical techniques, particularly in chromatography and . The adoption of internal standards in began in 1954, when N.H. Ray demonstrated their utility in gas-liquid for the of volatile organic compounds, such as fatty acids, by compensating for variations in sample injection and detector response. This breakthrough built on the foundational work of gas chromatography pioneers like James and , enabling more reliable measurements in complex mixtures. Concurrently, in flame photometry, the method was refined during the early 1950s to address matrix effects, with applications for precise determinations building on techniques like . By the 1960s, internal standards were integrated into atomic absorption spectrometry to correct for interferences in -based analyses, coinciding with the technique's and widespread adoption for detection. This era marked a shift toward routine use in environmental and clinical samples, where internal standards like for calcium measurements mitigated chemical and physical interferences, improving accuracy in low-concentration assays. The method's effectiveness was evident in applications for water and biological matrices, where it reduced errors from instability and sample variations, solidifying internal as a of spectroscopic quantification. In (NMR) spectroscopy, internal standards such as (TMS) became standard in the 1960s for referencing and quantification, paving the way for isotopic variants. The 1970s saw gain prominence as an innovation for internal standards, particularly in . Deuterated and ^{13}C-labeled analogs minimized suppression and overlap, allowing precise quantification in biological and metabolic studies. This approach, leveraging stable isotopes' near-identical chemical behavior but distinct mass signatures, enhanced sensitivity in gas chromatography-mass spectrometry (GC-MS) for trace organics and pharmaceuticals, reducing interference from matrix components. Regulatory advancements in the standardized internal standard use across pharmaceutical and environmental analyses, driven by agencies like the FDA and EPA to ensure reproducible and defensible results. The EPA's SW-846 methods, initiated in the mid- for characterization, mandated internal standards and techniques in protocols like Method 8275 (1987) for semivolatile organics via GC-MS, enabling accurate recovery corrections in complex environmental matrices. Similarly, FDA guidelines for analytical procedures in drug submissions during this period emphasized internal standards to validate robustness, influencing standardized practices in and stability testing.

Principles and Implementation

Selection Criteria for Internal Standards

The selection of an appropriate internal standard (IS) is crucial for ensuring accurate quantification in analytical methods, as it must closely mimic the analyte's behavior while avoiding any confounding influences. Ideal IS candidates are chosen based on their ability to compensate for variations in , instrument response, and matrix effects, thereby enhancing the reliability of results across diverse analytical techniques. Chemical similarity between the IS and the analyte is a primary criterion, requiring comparable extraction efficiency, ionization potential, and retention time to ensure proportional responses to procedural variations. For instance, in mass spectrometry, the IS should exhibit a resolvable signal, such as a distinct mass-to-charge ratio (m/z), while sharing structural features with the analyte to undergo similar ionization and fragmentation pathways. This similarity extends to physicochemical properties like polarity and solubility, allowing the IS to experience analogous matrix interactions without introducing bias. Non-interference is equally essential, mandating that the IS does not co-elute with the or react with sample components, thereby preventing signal overlap or suppression. The IS must also remain stable under the analytical conditions, including specific levels, temperatures, and compositions, to avoid or that could alter its concentration during processing. testing, often involving samples, confirms that the IS maintains consistent responses throughout the . Practical considerations further guide IS selection, including availability, cost-effectiveness, and in the sample matrix to facilitate uniform addition. The IS concentration is typically chosen to produce a signal approximately equal to that of the expected level to optimize signal-to-noise ratios and ensure it falls within the detector's linear range, avoiding saturation or under-detection. must match the analyte's to prevent or during preparation. Common pitfalls in IS selection include choosing compounds that partition differently in complex matrices, leading to uneven recovery and inaccurate corrections for losses. Similarly, selecting an IS prone to under analytical conditions can introduce variability, undermining the method's precision; thorough pre-validation checks, such as monitoring response consistency in spiked samples, help mitigate these issues.

Quantitative Methodology and Calculations

The quantitative methodology of the internal standard (IS) method relies on the ratio of the signal to the IS signal to determine the analyte concentration, compensating for variations in and instrumental response. The core equation is derived from the proportional relationship between signal and concentration: \frac{S_A}{S_{IS}} = K \frac{C_A}{C_{IS}} where S_A is the signal (e.g., area or ), S_{IS} is the IS signal, C_A is the analyte concentration, C_{IS} is the known IS concentration, and K is the representing the ratio of sensitivities (k_A / k_{IS}). Rearranging yields the analyte concentration: C_A = \frac{S_A}{S_{IS}} \cdot \frac{C_{IS}}{K} This approach ensures that systematic errors affecting both signals equally are minimized through . In the calibration process, a series of standards with varying known concentrations and a fixed C_{IS} are prepared and analyzed. The response ratios (S_A / S_{IS}) are plotted against the corresponding C_A values to generate a , typically following : \frac{S_A}{S_{IS}} = m C_A + b where m is the slope (equal to K / C_{IS}) and b is the y-intercept (ideally near zero for well-behaved systems). The response factor K is determined from the slope or from a single-point standard as K = (C_{A,std} / C_{IS,std}) \cdot (S_{IS,std} / S_{A,std}), where "std" denotes the standard. For an unknown sample, the measured ratio is substituted into the regression equation to solve for C_A. This multi-point enhances accuracy over single-point methods by accounting for potential non-linearity. Implementation involves the following steps: First, add a known volume or mass of IS solution to both standards and unknown samples prior to any preparation steps, ensuring the IS is chemically similar to the but resolvable (e.g., isotopically labeled). Second, perform the analysis to obtain S_A and S_{IS} for each. Third, compute the response ratio S_A / S_{IS} and apply it to the equation or to calculate C_A, adjusting for any dilution factors. This pre-analysis addition of the IS corrects for losses or inconsistencies during handling. The IS method reduces error propagation compared to direct signal measurements by focusing on the relative response, which mitigates multiplicative errors from injection volume, detector variability, or effects. The variance in the calculated C_A arises primarily from the uncertainties in S_A and S_{IS}; assuming independent Gaussian errors, the relative standard deviation of the ratio R = S_A / S_{IS} is approximately \sqrt{(\sigma_A / S_A)^2 + (\sigma_{IS} / S_{IS})^2}, leading to improved (often 2-5 times better than external standards in chromatographic applications). This ensures that proportional errors cancel out, enhancing overall reliability.

Applications

Nuclear Magnetic Resonance Spectroscopy

In (NMR) spectroscopy, internal standards play a crucial role in both chemical shift referencing and , particularly for proton (¹H) NMR spectra. A common internal standard is (TMS), which is added to the sample to provide a reference signal at 0 ppm due to its symmetric structure and inert nature, allowing for accurate determination of chemical shifts. In (qNMR), the internal standard enables precise measurement of concentrations by comparing signal intensities, compensating for instrumental variations and sample handling differences. The procedure for using an internal standard in NMR involves dissolving the in a deuterated , adding a known amount of the standard (such as TMS), and acquiring the spectrum under controlled conditions to ensure full relaxation. Peaks corresponding to the protons and the internal standard are then integrated and normalized by the number of contributing protons. The ratio of these normalized integrals is directly proportional to their molar concentrations, as the response factors for protons are unity under identical acquisition parameters. This ratio method, akin to general quantitative approaches in , simplifies calculations without needing response factor corrections for ¹H NMR. Internal standards offer significant advantages in NMR quantification by compensating for instrumental variations and sample handling differences, which can otherwise lead to inaccurate peak areas. They are particularly essential in , where complex mixtures require reliable to detect subtle concentration changes across samples. By stabilizing against variations in sample volume or instrument sensitivity, internal standards enhance reproducibility and accuracy in fields like pharmaceutical analysis. A key challenge in selecting an internal standard for NMR is ensuring its signals do not overlap with those of the analyte, as peak overlap can compromise integration accuracy and lead to quantification errors. Additionally, deuterated solvents, such as CDCl₃ or D₂O, are routinely employed not only to minimize solvent proton interference but also to provide a deuterium lock signal for magnetic field stabilization during acquisition. Careful choice of the standard's concentration and chemical compatibility with the sample is thus vital to avoid these issues.

Chromatographic Techniques

In chromatographic techniques such as (GC) and (HPLC), internal standards (IS) are employed to correct for variations in sample injection volume, detector response fluctuations, and potential analyte losses due to column degradation or matrix effects. By adding a known concentration of the IS to both calibration standards and samples prior to injection, the method normalizes analyte signals against the IS, enhancing quantitative accuracy across diverse sample matrices. This approach is particularly valuable in separation-based analyses where is challenged by instrumental inconsistencies. The standard procedure involves spiking a fixed amount of the IS into the sample solution before injection into the chromatographic system. Peak areas (or heights) of the target analytes are then measured relative to the IS peak, with quantification based on the ratio of these areas, which inherently compensates for changes in mobile phase or injection inconsistencies. For instance, in HPLC analysis of polycyclic aromatic hydrocarbons (PAHs), deuterated (naphthalene-d8) serves as an effective IS due to its structural similarity and distinct retention time, allowing reliable correction of recoveries and detector responses. This ratio-based ensures that systematic errors, such as those from partial volume evaporation in or gradient inconsistencies in HPLC, do not compromise results. The use of IS significantly improves , especially in HPLC where solvent composition changes can alter retention times and peak shapes. In bioanalytical applications, such as pharmacokinetic studies, deuterated analogs (e.g., stable isotope-labeled versions of drugs like olmesartan) are commonly used as IS in both and HPLC to account for extraction inefficiencies and ionization variations, providing quantification of plasma concentrations. These advantages make IS indispensable for achieving low limits of detection and high in complex biological or environmental samples. Technique-specific considerations guide IS selection: in GC headspace analysis of volatile organic compounds, the IS must be volatile and stable under equilibration conditions to mirror analyte partitioning into the gas phase, as seen in EPA methods for environmental volatiles. For HPLC with UV detection, the IS should exhibit strong UV absorption at the monitoring wavelength to ensure comparable detector sensitivity, facilitating accurate peak area ratios without additional derivatization.

Inductively Coupled Plasma Spectrometry

In (ICP) spectrometry, including atomic emission spectrometry () and (), internal standards play a crucial role in compensating for variations in plasma instability, nebulization efficiency, and matrix effects during . For trace metal determinations, elements such as are commonly employed as internal standards in ICP-AES to normalize analyte emission intensities against nonspectral interferences, ensuring improved across diverse sample matrices. In ICP-MS, internal standards like , , , , and correct for signal drift and physical interferences by providing a reference for ion counts, particularly in low-concentration analyses where plasma fluctuations can significantly impact results. The procedure for implementing internal standards in involves adding a known concentration of the standard—typically 20–200 μg/L for or similar levels calibrated to sample uptake—to both samples and calibration standards prior to introduction into the plasma. This addition can occur directly during or via an online mixing system, such as a , to maintain consistent delivery. Emission lines (in ) or ion signal intensities (in ) of both the analyte and internal standard are monitored simultaneously, with quantitative results derived from the ratio of their signals to account for variations in instrument response and sample introduction efficiency. These internal standards offer key advantages in ICP-MS by mitigating the effects of polyatomic interferences through normalization of signal suppression or enhancement caused by matrix components, which is particularly vital in modes without collision/reaction cells. For instance, serves as an effective internal standard in high-matrix samples, such as those with elevated dissolved solids, due to its ionization behavior and minimal endogenous presence, helping to maintain analytical reliability. This approach is essential for environmental analysis, where methods like EPA 200.8 rely on such standards to achieve precise quantification in complex matrices like wastewaters and sludges, while selection avoids spectral overlaps by choosing standards with distinct emission lines or masses from target analytes.

Examples

Case Study in High-Performance Liquid Chromatography

A practical example of internal standardization in (HPLC) involves the quantification of acetaminophen in human , essential for and assessment of overdose toxicity. serves as the internal standard (IS) due to its structural similarity to acetaminophen, similar retention time, and lack of interference from plasma components, allowing correction for inefficiencies and effects in biological samples. The procedure starts with spiking samples with at a final concentration of 10 µg/mL to normalize for procedural losses. For a typical 50 µL , 10 µL of stock solution (1 mg/mL in ) is added, followed by using 940 µL of ice-cold to deproteinize the matrix. The mixture is vortexed for 5 minutes and centrifuged at 13,200 rpm for 5 minutes at 4°C; 100 µL of the supernatant is then diluted with 400 µL of mobile phase (50% water with 0.1% : 50% with 0.1% ), vortexed, and filtered through a 0.22 µm . A 5 µL is injected onto a reversed-phase column (Acquity UPLC BEH Shield RP18, 1.7 µm, 2.1 × 100 mm) maintained at 40°C, with separation achieved using the mobile phase at 0.2 mL/min and /MS detection in MRM mode (m/z 152 → 110 for acetaminophen, m/z 180 → 138 for ). Peaks are integrated, and acetaminophen concentration is determined via the peak area ratio to , calibrated against a linear standard curve (1–100 µg/mL, r² > 0.998), which corrects for approximately 90% and mitigates suppression from phospholipids. This approach yields precise results, with intra-day RSD as low as 2.6% and inter-day RSD up to 15.8%, effectively compensating for matrix-induced variability in samples. By normalizing to the IS, the method achieves 90–100% accuracy across quality control levels and demonstrates robust mitigation of matrix effects, ensuring consistent quantification in clinical scenarios involving diverse patient samples. Validation followed MFDS bioanalytical guidelines, including assessments of , , accuracy, and , confirming the method's reliability for pharmaceutical in complex biological fluids, enhancing and eliminating biases from inconsistent (e.g., 5–10% volume errors) or injection variability. This case illustrates the practical advantages of internal standards in HPLC for pharmacokinetic studies and screening.

Case Study in Inductively Coupled Plasma Mass Spectrometry

In a practical application of internal standardization in (ICP-MS), researchers analyzed trace levels of lead in contaminated samples to assess environmental . was selected as the internal standard at a concentration of 5 ppb due to its similar behavior to lead and low natural abundance, minimizing isobaric interferences while correcting for matrix effects, including those from introduced during . This approach effectively addressed polyatomic interferences such as ⁴⁰Ar³⁵Cl⁺ species that could overlap with signals in chloride-rich matrices like digested soils. The procedure began with acid digestion of 0.25 g samples using a of 5 mL , 1 mL , and 2 mL in a system to ensure complete mineralization and release of bound metals like lead. Post-digestion, the internal standard () was spiked into the diluted extracts before nebulization into the , where samples were ionized and separated by . Quantification relied on the ratio of lead counts (primarily at m/z 208) to counts (m/z 103), calibrated against multi-point standards to account for instrument drift and matrix-induced variations. This ratio-based method corrected for up to 20% signal suppression observed in complex matrices, enhancing accuracy without additional separation steps. The results demonstrated improved analytical performance, with a limit of detection for lead reaching 0.128 ppb and relative standard deviation below 5% across replicates, reflecting the internal standard's effectiveness in stabilizing signals amid and other matrix interferences. Recoveries for lead and co-analytes ranged from 97% to 116%, validating the method's reliability for trace-level quantification. This case exemplifies the robustness of internal standardization in EPA Method 6020, which has been widely adopted for of metals in complex solid matrices like soils, ensuring compliance with regulatory limits for contaminants.

References

  1. [1]
    internal standard (I03108) - IUPAC Gold Book
    A compound added to a sample in known concentration to facilitate the qualitative indentification and/or quantitative determination of the sample components.
  2. [2]
    [PDF] Evaluation of Internal Standard Responses During Chromatographic ...
    A1: In analytical chemistry, ISs are usually a structural analog or stable isotope of an analyte of interest and are commonly used in chromatographic analytical ...
  3. [3]
    [PDF] INTERNAL STANDARD CALIBRATION
    Internal standard calibration involves the comparison of the instrument responses from the target compounds in the sample to the responses of reference ...
  4. [4]
    Internal Standards for Quantitative Analysis of Chemical Warfare ...
    Aug 11, 2020 · When applying the internal standard, it is always necessary to evaluate the intensity of the analyte and standard chromatographic peaks. The TIC ...
  5. [5]
    Internal standard variability: root cause investigation, parallelism for ...
    May 8, 2024 · An IS is defined as “A structurally similar analogue or stable isotope labeled compound added to calibration standards, QCs, and study samples ...
  6. [6]
    Precision of Internal Standard and External Standard Methods in ...
    Apr 1, 2015 · The internal standard method is used to improve the precision and accuracy of results where volume errors are difficult to predict and control.
  7. [7]
    Internal Standardization In Chromatography Explained
    Using an internal standard is a powerful tool for minimising the effects of random and systematic errors during analysis, helping to improve the precision of ...
  8. [8]
    Key Points to Remember When Using Internal Standards for Sample ...
    Aug 2, 2023 · Using internal standards is a common technique to correct for variations in sample matrices and the effect this has on analyte intensities.
  9. [9]
    When Should an Internal Standard be Used? | LCGC International
    First, it is more convenient and less expensive because the extra step of adding the IS during sample preparation is eliminated. Second, the chromatogram is ...
  10. [10]
    Internal Standard vs. External Standard Methods in ... - Alfa Chemistry
    Advantages of the internal standard method: High immunity to interference—counteracts the effects of injection volume errors, mobile phase fluctuations ...
  11. [11]
    Internal Standards and LOD - Chemistry LibreTexts
    Oct 20, 2020 · Internal standards are useful to compensate for changes in extraction efficiency, detector response due to sample loss during other sample ...
  12. [12]
    Video: Internal Standards for Quantitative Analysis - JoVE
    Aug 24, 2015 · For internal standards, the standard is in the same sample as the analyte of interest, allowing the measurement to be taken simultaneously.<|control11|><|separator|>
  13. [13]
    1.5: Calibration of Instrumental Methods - Chemistry LibreTexts
    Jan 22, 2023 · An external standardization allows us to analyze a series of samples using a single calibration curve. This is an important advantage when we ...Missing: definition disadvantages
  14. [14]
    Traditional Calibration Methods in Atomic Spectrometry and New ...
    It is called external standard calibration because certified pure substances or standard solutions used in the calibration procedure are external to the sample.Missing: disadvantages | Show results with:disadvantages
  15. [15]
    None
    ### Summary of External Standard Calibration
  16. [16]
    Standard additions: myth and reality - Analyst (RSC Publishing)
    Apr 29, 2008 · Standard additions: myth and reality. S. L. R. Ellison and M. Thompson, Analyst, 2008, 133, 992 DOI: 10.1039/B717660K. To request permission ...
  17. [17]
    The standard addition method and its validation in forensic toxicology
    Jun 4, 2021 · Advantages and disadvantages of the standard addition method. The first advantage to be mentioned for SAM is that it does not need a blank ...Missing: definition | Show results with:definition
  18. [18]
    Origins of the method of standard additions and of the use of an ...
    Apr 2, 2019 · The first use of an internal standard was that by Gouy in 1887 in flame emission spectroscopy. Following the extensive studies by Gerlach of the ...Missing: 1890s titrimetric
  19. [19]
  20. [20]
  21. [21]
    Flame Atomic Absorption Spectrometry - ScienceDirect.com
    During the 1960s flame AAS became the dominant technique for determinations of the elements in low concentrations in water samples and aqueous extracts of other ...<|separator|>
  22. [22]
    Internal standardization in atomic emission and absorption ...
    Internal standard method in flame atomic absorption spectrometry. Spectrochimica Acta Part B: Atomic Spectroscopy 1981, 36 (7) , 735-745. https://doi.org ...
  23. [23]
    Stable isotope compounds - production, detection, and application
    ... mass spectrometry in the 1970s. The biggest boom of stable isotope use came with the new millennium and it is connected with quantitative proteomics ...
  24. [24]
    Historical and contemporary stable isotope tracer approaches to ...
    May 16, 2016 · This historical review details the development of stable isotope tracers as metabolic tools, with particular reference to their use in monitoring protein ...
  25. [25]
    [PDF] semi-volatile organic compounds by isotope dilution gc/ms
    The internal standard method is also applied to determination of compounds having no labeled analog, and to measurement of labeled compounds for intra- ...
  26. [26]
    [PDF] Guidance for Industry - FDA
    This guidance represents the Food and Drug Administration's (FDA's) current thinking on this topic. It does not create or confer any rights for or on any ...Missing: EPA | Show results with:EPA
  27. [27]
    Statistics in Analytical Chemistry: Part 19—Internal Standards
    An internal standard (IS) is a non-analyte compound added to all samples and standards. It scales responses, especially when recoveries differ from 100%.
  28. [28]
    Guidelines for Selection of Internal Standard-Based Normalization ...
    Jun 26, 2019 · Isotopically-labelled internal standards are applied to assess system stability for each sample analysed. Pooled QC samples are applied to ...
  29. [29]
    (PDF) Internal Standard—Friend or Foe? - ResearchGate
    Oct 18, 2009 · In general, the use of an internal standard in the GC-FID analysis is commonly used to correct random errors from the injection repeatability ...
  30. [30]
    [PDF] Chapter 5
    A sixth spectrophotometric method for the quantitative analysis of Pb2+ in blood uses Cu2+ as an internal standard. A standard containing 1.75 ppb. Pb2+ and ...
  31. [31]
    None
    ### Extracted Formulas and Steps for Internal Standard Method
  32. [32]
    Tetramethylsilane - American Chemical Society
    Mar 29, 2021 · Tetramethylsilane (TMS) is a volatile liquid, used as a standard in NMR spectroscopy, and is the simplest tetraalkylsilane. Its 1H chemical ...
  33. [33]
    Quantitative 1H NMR: Development and Potential of an Analytical ...
    Among the foremost advantages of qHNMR is its accurate function with external calibration, the lack of any requirement for identical reference materials, a high ...
  34. [34]
    1H NMR analysis of mixtures using internal standards: A quantitative ...
    1H NMR analysis of mixtures using internal standards: A quantitative experiment for the instrumental analysis laboratory | Journal of Chemical Education.
  35. [35]
    Method development in quantitative NMR towards metrologically ...
    The quantification by NMR is based on a signal comparison of the analyte with an internal or external reference standard. In contrast to other methods, e.g., ...
  36. [36]
    [PDF] Quantitative NMR-Based Biomedical Metabolomics
    Nov 4, 2020 · Internal standards have long been used in qNMR techniques due to their high level of accuracy and precision [52,53]. Compounds commonly used as ...
  37. [37]
    Research Progress of NMR in Natural Product Quantification - PMC
    Oct 19, 2021 · Nuclear magnetic resonance spectroscopy has certain advantages in the quantitative analysis of substances, such as being nondestructive, having ...<|control11|><|separator|>
  38. [38]
    Pharmaceutical Application of Quantitative NMR | Analytical Chemistry
    The distinct advantages of q-NMR are (1) its ability to determine potency without having a standard, (2) it is quicker, and (3) it is more economical.
  39. [39]
    Solvent Signal is a NMR Concentration Reference - PMC - NIH
    Residual solvent protons can always be observed by NMR for any partially or highly deuterated solvent in real life. For an example, even with 99.9% deuteration, ...
  40. [40]
    Validated Quantitative 1H NMR Method for Simultaneous ...
    Nov 16, 2021 · Extended internal standard method for quantitative 1H NMR assisted by chromatography (EIC) for analyte overlapping impurity on 1H NMR spectra.
  41. [41]
    None
    ### Summary of Internal Standard Method in GC and LC
  42. [42]
    None
    ### Summary of Internal Standards in Chromatography
  43. [43]
    [PDF] Polynuclear Aromatic Hydrocarbons in AIR by GC-MS SIM - CDC
    Internal standard spiking solution: naphthalene-D8, acenaphthene-D10, phenanthrene-D10, chrysene-D12, and perylene-D12 at about 100 µg/mL in methylene chloride.
  44. [44]
    Selection of internal standards for accurate quantification of complex ...
    This review addresses the selection of internal standards in different methods for accurate quantification of individual lipid species.
  45. [45]
    Is a deuterated internal standard appropriate for the reliable ...
    Jan 1, 2017 · The use of deuterated olmesartan as the internal standard afforded a reliable tool for regulatory bioanalysis that can indirectly contribute to ...
  46. [46]
    [PDF] Method 8260C: Volatile Organic Compounds by Gas ... - US EPA
    Recoveries were calculated using internal standard method. The internal standard was fluorobenzene. b. Standard deviation was calculated by pooling data from ...
  47. [47]
    Important Aspects of UV Detection for HPLC - LCGC International
    Nov 1, 2015 · The standard ultraviolet (UV) detector for high performance liquid chromatography (HPLC) measures the absorbance of monochromatic light of fixed wavelength.
  48. [48]
    An Overview of the Use of Yttrium for Internal Standardization in ...
    In our discussed review, we present several reports of ICP-AES techniques that employ yttrium as the internal standard.
  49. [49]
    [PDF] EPA Method 200.8: Determination of Trace Elements in Waters and ...
    Procedures described in this method for general application, detail the use of five internal standards; scandium, yttrium, indium, terbium and bismuth. These ...
  50. [50]
    Inductively Coupled Plasma Mass Spectrometry: Introduction to ...
    Common Internal Standards and Other Analytical Issues. Internal standards commonly used in ICP-MS include lithium (6Li), scandium (45Sc), germanium (72Ge) ...
  51. [51]
    Using Indium as your internal standard - Inorganic Ventures
    Our thought is that if we use an internal standard, then we would need to add it to the standards as well as the samples.
  52. [52]
    [PDF] TCP - Development and validation of a UPLC-MS/ MS method for ...
    Mar 15, 2016 · A lot of methods have been reported for the determination of acetaminophen concentrations in human plasma. Although liquid chromatography (LC) ...
  53. [53]
    Precision of Internal Standard and External Standard Methods in ...
    Internal standard methods are used to improve the precision and accuracy of results where volume errors are difficult to predict and control.<|control11|><|separator|>
  54. [54]
    determination of pollutants in soil by multi-element analysis on icp-ms
    Jul 3, 2019 · All the samples were spiked with. known amount of Rhodium (5ppb) as internal standard. Accurate results of recovery 97% - 116%. was obtained ...
  55. [55]
    [PDF] Method 6020B: Inductively Coupled Plasma - Mass Spectrometry ...
    An internal standard can be used to correct for physical interferences, if it is carefully matched to the analyte so that the two elements are similarly ...