Fact-checked by Grok 2 weeks ago

Passive optical network

A passive optical network (PON) is a point-to-multipoint fiber-optic architecture that delivers high-speed services to multiple end-users via a single shared , utilizing unpowered optical splitters and no active electronic components in the distribution infrastructure to transmit data signals. The system typically consists of an optical line terminal (OLT) at the provider's central office, which serves as the data source, connected through passive splitters to optical network units (ONUs) or optical network terminals (ONTs) at customer premises, enabling efficient signal distribution over distances up to 20 kilometers while supporting up to 128 users per fiber strand. This design contrasts with active optical networks by relying solely on from the OLT for downstream broadcast transmission at wavelengths like 1490 nm and upstream (TDMA) at 1310 nm, eliminating the need for powered and reducing operational costs. PON technology has evolved through standardized generations to meet growing bandwidth demands, primarily under and IEEE frameworks. The ITU-T's Asynchronous Transfer Mode PON (APON/BPON, G.983) provided early deployments with up to 622 Mbps downstream, followed by (GPON, G.984) offering 2.488 Gbps downstream and 1.244 Gbps upstream for widespread fiber-to-the-home (FTTH) adoption. Subsequent advancements include 10-Gigabit-capable PON (XG-PON, G.987) with 10 Gbps downstream and 2.5 Gbps upstream, and symmetric XGS-PON (G.9807) achieving 10 Gbps bidirectional speeds, while 50G-PON (G.9804), standardized in 2021 with further refinements by 2024, supports up to 50 Gbps and has seen initial deployments as of 2025 for and ultra-broadband applications. Complementing these, IEEE's (EPON, 802.3ah) delivers 1 Gbps symmetric Ethernet-based services over passive infrastructure, with (802.3av) and multi-wavelength 25G/50G-EPON (802.3ca) extending capabilities for carrier-grade applications. Key advantages of PON include its cost-efficiency due to reduced equipment and maintenance needs, high reliability from the absence of active field components, and scalability for delivering triple-play services like , , and video without extensive deployment. Widely deployed globally for FTTH/FTTB, PON supports secure, low-latency connections and integrates with emerging technologies like (WDM) in next-generation variants such as (G.989), which aggregates up to 40 Gbps across multiple wavelengths.

Fundamentals

Definition and Principles

A passive optical network (PON) is a telecommunications system that delivers high-speed broadband services via optical fiber from a central office to multiple end-users, employing a point-to-multipoint architecture without active electrical components in the distribution stage. This setup enables efficient sharing of the fiber infrastructure among numerous subscribers, typically up to 32 or more, by broadcasting downstream signals to all connected endpoints while aggregating upstream transmissions. The core advantage lies in its cost-effectiveness, as it minimizes the need for powered equipment in the external plant, relying instead on the inherent properties of light propagation in fiber. The fundamental principles of PON operation center on a tree-like topology where a single feeder fiber from the central office branches out via passive optical splitters to distribute signals to end-users. Downstream traffic is broadcast unidirectionally from the central office to all optical network units (ONUs) at customer premises, with each ONU filtering the relevant data. Upstream traffic, in contrast, employs time-division multiple access (TDMA) to prevent collisions, allowing multiple ONUs to share the same return path by transmitting in assigned time slots. Wavelength-division multiplexing (WDM) further separates bidirectional flows: for instance, in Gigabit PON (GPON) systems, downstream signals operate at approximately 1490 nm, while upstream uses 1310 nm, enabling full-duplex communication over a single fiber pair. The passive elements, such as splitters and connectors, require no electrical power, as they simply divide or combine optical power based on physical optics, enhancing reliability and reducing maintenance in the outside plant. Prerequisite to PON functionality are the basics of optical fiber transmission and multiplexing techniques. Optical fibers, typically single-mode types compliant with ITU-T G.652 standards, guide light signals through total internal reflection within a silica core surrounded by a cladding of lower refractive index, supporting low-loss propagation over distances up to 20 km or more in PONs. Multiplexing fundamentals include WDM for wavelength-based separation of data streams and TDMA for time-sliced sharing among users, which together optimize utilization in the shared medium without active signal regeneration.

Key Characteristics

Passive optical networks (PONs) offer several key advantages that make them suitable for broadband access. They provide high bandwidth capabilities, with modern variants such as XGS-PON delivering up to 10 Gbps symmetric speeds in both upstream and downstream directions. Due to their passive nature, lacking active electronic components in the distribution network, PONs require minimal maintenance and exhibit high reliability with fewer points of failure. They are scalable, typically supporting 32 to 128 users per optical splitter, enabling efficient service to multiple endpoints from a single fiber trunk. Additionally, PONs are cost-effective for last-mile delivery, as the shared infrastructure reduces the need for extensive cabling compared to dedicated lines. Despite these benefits, PONs have notable disadvantages. The shared among users can lead to contention during peak usage, potentially degrading individual performance. Their reach is limited, typically to about 20 km from the central office, constrained by optical signal . Furthermore, the upfront costs for deployment are higher than those for copper-based alternatives, although long-term savings offset this through reduced operational expenses. Performance in is governed by budget calculations, which determine the allowable signal loss. The loss budget is computed as the difference between transmitter output and receiver , from which losses due to fiber attenuation (typically 0.35 / at 1490 ), splitter insertion (e.g., 17-18 for a 1x32 splitter), and connectors are subtracted to ensure sufficient margin. For systems, a typical loss budget is 28 under G.984 standards, supporting the aforementioned reach and split ratios. Compared to active optical networks (AONs), demonstrate superior energy efficiency, as passive splitters consume no power, reducing overall electricity use by up to 95% relative to systems and avoiding the powered switches in AONs. In terms of reliability, benefit from simpler architectures with no intermediate active , leading to lower failure rates and easier fault isolation than the more complex, power-dependent AON setups.

Historical Development

Early Innovations

The concept of passive optical networks (PONs) originated in the late , when researchers at proposed a point-to-multipoint using unpowered optical components to distribute signals efficiently to multiple users. In a seminal 1987 paper, J.R. Stern and colleagues described a tree topology for local , leveraging passive elements to support and emerging applications while minimizing infrastructure costs compared to active electronic switches. This approach addressed the growing demand for higher-speed access in the , driven by the expansion of services and the limitations of copper-based (DSL) technologies, which struggled to deliver symmetric, high-bandwidth connectivity for data-intensive uses. Central to these early designs were passive optical splitters, such as fused biconical taper couplers, which enabled signal distribution from a central office to end users without requiring power at intermediate points, thereby reducing operational expenses and enhancing reliability. Concurrently, the invention of erbium-doped fiber amplifiers (EDFAs) in the late 1980s provided a breakthrough by allowing optical amplification at the 1550 nm wavelength, extending feasible transmission reaches to 20 km or more in access networks without active repeaters, which was critical for serving dispersed residential areas. The first field trials of PON technology occurred in the early 1990s, with launching the world's inaugural deployment at , , in 1990 to test PON (T-PON) for voice services to up to 500 residential and business customers over shared fiber infrastructure. These experiments demonstrated practical viability, including time-division multiple access (TDMA) for upstream traffic, and were soon upgraded to Broadband PON (B-PON) prototypes in 1991, incorporating (ATM) to support integrated voice, data, and video transmission. Such pre-standardization efforts highlighted PON's potential for scalable, cost-effective fiber deployment, paving the way for industry collaboration through initiatives like the Full Service Access Network (FSAN) consortium formed in 1995.

Standardization Efforts

The Full Service Access Network (FSAN) consortium was established in 1995 by major telecommunications operators to coordinate the development of optical technologies, including PON systems, with a focus on defining minimum requirements for optical transceivers and network architectures. FSAN's efforts directly influenced the Telecommunication Standardization Sector (), leading to the adoption of the first PON , ITU-T G.983, which specified Asynchronous Transfer Mode-based PON (APON) or Broadband PON (BPON) in 1998. This laid the groundwork for point-to-multipoint optical , supporting asymmetric rates up to 622 Mbit/s downstream and 155 Mbit/s upstream over a 20 km reach with a 1:32 split ratio. Subsequent ITU-T advancements built on this foundation to address growing bandwidth demands. The G.984 series, defining Gigabit PON (GPON), was ratified in 2003, introducing gemini framing for efficient packet transport and asymmetric rates of 2.488 Gbit/s downstream and 1.244 Gbit/s upstream. In 2010, the G.987 series for 10-Gigabit-capable PON (XG-PON) extended capabilities to 10 Gbit/s downstream and 2.5 Gbit/s upstream, emphasizing coexistence with legacy GPON deployments. The G.989 series for Next-Generation PON 2 (NG-PON2), developed between 2012 and 2015, supported up to 40 Gbit/s aggregate capacity via time and wavelength division multiplexing, enabling multi-wavelength overlays for enhanced flexibility. More recently, the G.9804 series for 50G-PON, with key specifications approved in 2023, targets symmetric 50 Gbit/s rates and has been positioned for mobile backhaul applications, with field trials demonstrating in 2024 and early 2025. Parallel standardization occurred under the Institute of Electrical and Electronics Engineers (IEEE), focusing on Ethernet-based PON variants. The 802.3ah amendment, approved in 2004, defined Ethernet PON (EPON) with 1 Gbit/s symmetric rates using Ethernet framing for simpler integration with existing networks. This was followed by 802.3av in 2009 for , supporting asymmetric 10 Gbit/s downstream and 1 Gbit/s upstream while maintaining with EPON. The 802.3ca amendment, ratified in 2020, introduced 25G/50G-EPON options, achieving up to 50 Gbit/s symmetric operation over single-mode with enhanced for longer reaches. Early PON standards like APON/BPON under G.983 exhibited security vulnerabilities, including lack of , which exposed downstream broadcast traffic to and upstream data to interception by rogue optical network units (). Improvements in via G.984.3, ratified in 2004, addressed these by mandating () for both upstream and downstream traffic, along with ONU authentication mechanisms to prevent unauthorized access. These enhancements set a precedent for security in subsequent and IEEE PON standards, ensuring protection against common threats in shared optical environments.

System Architecture

Network Elements

The Optical Line Terminal (OLT) serves as the central active device in a Passive Optical Network (PON), typically located at the service provider's headend or central office, where it aggregates traffic from the core network and distributes it to multiple end users via optical fibers. It performs key functions including downstream data onto a single optical wavelength, managing and (QoS), and implementing dynamic bandwidth allocation () to efficiently share capacity among connected users. The OLT also handles upstream signal reception, performing ranging to synchronize optical network units and mitigate in shared mediums. At the customer premises, Optical Network Units (ONUs) or Optical Network Terminals (ONTs) act as the endpoint devices that interface between the PON and , converting incoming optical signals to electrical signals for devices such as routers, computers, or telephones. ONTs, as defined in standards, and ONUs, per IEEE terminology, often integrate (SFP) modules for optical transceivers and can combine with home gateways to provide Ethernet, voice, and video services. These units perform signal termination, protocol adaptation, and basic management functions like alarm reporting to the OLT. PON architectures employ passive optical splitters to distribute signals from the OLT to multiple ONUs/ONTs, commonly configured in 1xN ratios such as 1:32, which allow a single feeder fiber to serve up to 32 endpoints while maintaining acceptable power budgets. These splitters are deployed in the , often within distribution cabinets, aerial enclosures, or underground vaults, to enable point-to-multipoint without active . This configuration relies on the principle of passive power splitting to divide optical signals equally among outputs. Recent advancements in PON have introduced virtual OLTs (vOLTs), which virtualize OLT functions on general-purpose servers using (NFV) and (SDN) to enable cloud-based orchestration and disaggregation of hardware. vOLTs support multi-vendor interoperability by abstracting control planes through open protocols like VOLTHA, reducing and improving in centralized data centers. This evolution facilitates dynamic resource allocation and integration with backhaul, addressing limitations of traditional hardware-centric OLTs.

Passive Components

Passive components in a passive optical network (PON) are unpowered optical devices that facilitate the distribution and routing of optical signals without requiring electrical power, enabling cost-effective and reliable point-to-multipoint architectures. These elements primarily include optical splitters, connectors, splices, and the optical distribution network (ODN) infrastructure, which collectively manage signal splitting, interconnection, and transmission paths while minimizing losses to fit within the system's budget. By relying on passive , these components support high in fiber-to-the-home (FTTH) deployments, where a single feeder signal from the optical line terminal (OLT) is divided to serve multiple end-users. Optical splitters are central to PON functionality, dividing an incoming optical signal from the feeder into multiple output paths for downstream to optical network units (ONUs). The two primary types are fused biconic taper (FBT) splitters and planar lightwave circuit () splitters. FBT splitters are fabricated by twisting and fusing multiple optical in a biconical taper, heated to create a region that splits light based on the ratio of fused lengths; they are cost-effective for low split ratios but exhibit higher wavelength-dependent losses and less uniformity across outputs. In contrast, splitters use silica-based planar technology etched onto a substrate, offering compact designs with excellent uniformity, low polarization-dependent loss, and broad independence, making them ideal for PON applications across C-band wavelengths (1530-1565 nm). Insertion loss in optical splitters arises from the splitting ratio and excess losses due to material absorption and coupling inefficiencies, directly impacting the PON's reach and split capacity. For a 1:2 splitter, typical insertion loss is approximately 3.5 , representing the theoretical 3 splitting loss plus about 0.5 excess; for higher ratios like 1:32, it increases to around 17 , limiting the number of users per PON tree unless compensated by higher launch power. PLC splitters demonstrate superior wavelength independence, with insertion loss variations under 0.5 across a 40 nm bandwidth, compared to FBT's 1-2 fluctuations, ensuring consistent performance in multi-wavelength environments. In emerging 50G-PON systems, advanced low-loss PLC splitters with excess losses below 1 enable higher split ratios (up to 1:64) and extended reach to support symmetric 50 Gbps rates while maintaining adequate margins in the optical power budget. Connectors and splices provide interconnection points in the PON, ensuring low-loss mating of fibers while minimizing reflections that could degrade signal quality. The SC/APC (Subscriber Connector/Angled Physical Contact) connector is widely used in PON due to its 8-degree polish angle, achieving return losses exceeding 60 to suppress back-reflections in bidirectional transmission; typical per mated pair is 0.2-0.3 . splices, created by melting fiber ends with an for permanent joints, offer even lower of about 0.1-0.2 per , far superior to mechanical alternatives, and are essential for field installations to reduce cumulative losses in long cable runs. These low-loss interconnections contribute to the overall power budget, allowing PONs to accommodate up to 20-30 of total from OLT to . The optical distribution network (ODN) forms the passive backbone of a PON, comprising a hierarchical layout of and splitters that routes signals from the OLT to multiple ONUs. It typically includes a feeder segment connecting the OLT to the first point (often 5-20 km long), branching from splitters to secondary access points, and drop extending the final short spans (under 500 m) to individual customer premises. This tree-like structure, with splitters housed in weatherproof enclosures at and access points, optimizes usage and enables scalable deployments serving 32-128 users per OLT port.

Operational Mechanisms

Transmission Protocols

In passive optical networks (PONs), data transmission occurs bidirectionally over a shared optical fiber medium without active electronic components in the distribution infrastructure, relying on time-division multiplexing (TDM) for downstream traffic and time-division multiple access (TDMA) for upstream traffic to manage the point-to-multipoint topology. Downstream transmission from the optical line terminal (OLT) to all optical network units (ONUs) operates in broadcast mode using TDM, where the OLT continuously transmits data packets that are received by every ONU, with each ONU filtering packets addressed to it based on identifiers in the frame headers. In Gigabit PON (GPON) systems defined by ITU-T G.984, downstream data is encapsulated in GPON Encapsulation Method (GEM) frames within fixed-length gigabit-capable PON transmission convergence (GTC) frames of 125 μs duration, supporting rates up to 2.488 Gbit/s at a wavelength of approximately 1490 nm using continuous-wave modulation. In Ethernet PON (EPON) systems per IEEE 802.3ah, downstream traffic employs standard Ethernet frames broadcast at 1 Gbit/s over approximately 1490 nm, also in continuous mode to ensure constant signal presence for all ONUs; 10 Gbit/s extensions per IEEE 802.3av use different downstream wavelengths such as 1577 nm to support coexistence with 1G EPON. Upstream transmission from ONUs to the OLT uses TDMA to prevent collisions on the shared medium, where each ONU transmits short bursts of data during precisely assigned time slots, synchronized by the OLT via control messages in the downstream channel. These bursts occur at a wavelength of around 1310 nm and require burst-mode receivers at the OLT to rapidly acquire and lock onto incoming signals with varying power levels and phases, as opposed to the steady continuous-mode reception in point-to-point links. In , upstream GEM frames are carried in dynamic-length GTC allocation intervals, with each burst including a preamble for , a for , and idle bits, while EPON upstream bursts consist of Ethernet prefixed with multi-point control protocol (MPCP) elements for timing coordination. To accommodate the burst-mode upstream operation, specific timing parameters ensure seamless transitions between ONU transmissions, including a guard time to allow OLT receiver reset, typically 32 bits in GPON to cover laser turn-off and receiver recovery without data loss. The guard time T_g in bit times satisfies T_g = 32 for standard GPON implementations, providing sufficient margin for optical power transients. Unlike dedicated point-to-point fiber links, the PON's shared upstream path demands ranging procedures during ONU activation, where the OLT measures round-trip propagation delays to distant ONUs—up to 20 km or more—and assigns an individual equalization delay (EqD) to each ONU, aligning burst arrivals at the OLT despite varying fiber lengths. This EqD, calculated as the difference between a reference delay and the measured round-trip time, is periodically updated to compensate for environmental drifts, ensuring collision-free TDMA without active repeaters.

Bandwidth Allocation

In passive optical networks (PONs), bandwidth allocation primarily addresses the upstream direction, where multiple optical network units (ONUs) share the medium using (TDMA). Dynamic Bandwidth Allocation () is the core mechanism employed by the optical line terminal (OLT) to fairly and efficiently distribute upstream among ONUs based on their real-time traffic demands, preventing collisions and optimizing resource utilization. In Gigabit PON () systems, as defined by G.984.3, DBA operates through two primary modes: status-reporting DBA (SR-DBA) and credit-based DBA (also known as non-status reporting DBA or NSR-DBA). SR-DBA relies on explicit queue reports from ONUs, while credit-based DBA infers bandwidth needs through OLT monitoring of traffic patterns without requiring ONU . In SR-DBA, each ONU reports its buffer occupancy—measured in ATM cells or GEM blocks—via the dynamic bandwidth report upstream (DBRu) field in the upstream physical layer overhead (PLOu). The OLT uses these reports to calculate and assign transmission grants to transmission containers (T-CONTs), which are logical channels identified by allocation IDs (Alloc-IDs). Credit-based DBA, in contrast, enables the OLT to dynamically adjust allocations by observing idle GEM frame patterns and comparing them against maps, effectively granting "credits" for observed underutilization without explicit reporting. This mode supports ONUs that may not provide status updates, ensuring continuous operation. Both modes allow the OLT to issue grants in the bandwidth map within the generic framing procedure (GFP) downstream frame, scheduling ONU transmissions in precise time slots. Grant algorithms in categorize into fixed, assured, non-assured, and best-effort types to prioritize traffic classes and meet quality-of-service (QoS) requirements. Fixed grants provide a constant allocation regardless of , suitable for constant services. Assured grants guarantee up to a specified maximum for high-priority traffic, based on reported sizes, ensuring low . Non-assured grants serve surplus for moderate-priority flows when available, while best-effort grants allocate remaining capacity to low-priority traffic on a basis, often using weights for fairness. ONUs report statuses for different T-CONT types (e.g., types 2-5 for assured and best-effort), enabling the OLT to prioritize assured over best-effort allocations in the . Grant sizing typically combines reported queue lengths with predictions of incoming traffic to minimize delays and overhead. A common approach calculates the grant as the sum of the reported queue size and an estimate of predicted traffic during the reporting interval, formulated as: \text{Grant} = \text{Reported Queue} + \text{Predicted Traffic} where predicted traffic may use statistical models like moving averages to forecast arrivals. This method reduces idle times and over- or under-allocation. In modern GPON systems, these DBA techniques achieve upstream efficiency exceeding 90%, with effective utilization reaching up to 92% due to efficient GEM framing and adaptive granting, compared to 70-80% in less optimized Ethernet PONs. Emerging advancements incorporate (AI) and (ML) for predictive DBA, enhancing integration with networks such as cloud radio access networks (C-RAN). These methods use models to forecast traffic patterns from historical data, enabling proactive grant adjustments that reduce in mobile fronthaul scenarios. For instance, neural networks predict ONU demands to minimize reporting overhead, achieving up to 20% better throughput in simulated -PON convergences compared to traditional SR-DBA. Such AI-enhanced DBA addresses bursty traffic variability, supporting ultra-reliable low- communications.

Variants and Standards

Time-Division Multiplexing PON

Time-division multiplexing (TDM) in passive optical networks (PONs) enables efficient sharing of the among multiple optical network units (ONUs) by dynamically allocating upstream time slots from the optical line terminal (OLT), while downstream traffic is broadcast to all ONUs. The PON (APON), later enhanced as Broadband PON (BPON) under Recommendation G.983, represents the earliest standardized TDM-PON variant. APON/BPON operates at downstream rates of 622 Mbps and upstream rates of 155 Mbps over a single using ATM framing for data transport. It employs for separate upstream (1310 nm) and downstream (1550 nm) signals, supporting up to 32 ONUs per splitter with a maximum reach of 20 km. Security in BPON relies on a basic churning mechanism for . Gigabit PON (), defined in G.984 series, advanced TDM-PON capabilities with higher speeds and improved efficiency. It provides asymmetric rates of 2.488 Gbps downstream and 1.244 Gbps upstream, using Generic Encapsulation Method (GEM) to transport Ethernet, , and TDM services over a flexible frame structure. GPON maintains the 1310 nm upstream and 1490 nm downstream wavelengths, supporting up to 128 ONUs and reaches up to 60 km with appropriate . AES-128 is standard for downstream traffic to prevent , with upstream isolation via TDM. Widely deployed since 2005, GPON enabled mass-market fiber-to-the-home services due to its cost-effective scaling. Next-generation TDM-PON standards include 10-Gigabit-capable PON (XG-PON) under G.987 and symmetric XG-PON (XGS-PON) under G.9807. XG-PON delivers asymmetric 10 Gbps downstream and 2.5 Gbps upstream, using an extended GEM frame for enhanced and dynamic bandwidth allocation. XGS-PON achieves symmetric 10 Gbps in both directions, operating at 1577 nm downstream and 1270 nm upstream for coexistence with infrastructure. Both maintain with GPON through separation and protocol adaptations, allowing overlay on existing deployments without full replacement. Ethernet PON (EPON), standardized as IEEE 802.3ah, offers a 1 Gbps symmetric alternative using native Ethernet framing over TDM. It broadcasts downstream Ethernet frames at 1490 nm and uses 1310 nm for burst-mode upstream TDMA, supporting up to 64 ONUs and 20 km reach. The extension in IEEE 802.3av scales to 10 Gbps symmetric rates, with options for asymmetric modes, while preserving Ethernet simplicity and encryption for both directions. Key differences among these TDM-PON variants lie in framing and encapsulation: APON/BPON and use ATM or GEM over SONET-like overhead for telco compatibility, whereas and employ direct Ethernet frames for simpler integration with networks. varies, with BPON's churning providing basic protection, mandating -128 downstream, and EPON/10G-EPON supporting bidirectional . These distinctions influence deployment choices, with standards favoring service versatility and IEEE standards prioritizing Ethernet native performance.

Wavelength-Division and Hybrid PON

Wavelength-division multiplexing passive optical networks (WDM-PONs) assign dedicated downstream and upstream wavelength channels to individual optical network units (ONUs) or groups of users, enabling each to access the full of their allocated without contention. This architecture leverages arrayed waveguide gratings (AWGs) or thin-film filters at the remote node to demultiplex signals, supporting point-to-multipoint topologies while maintaining the passive of the . To facilitate and reduce inventory costs, colorless ONUs are commonly employed, utilizing tunable lasers or wavelength-seeded schemes such as injection locking, where a central office provides light that ONUs lock onto for upstream transmission. Time and wavelength division multiplexing PON (TWDM-PON), standardized as next-generation PON 2 (NG-PON2) in ITU-T G.989, extends WDM principles by combining multiple wavelengths with TDM on each lambda, achieving an aggregate capacity of 40 Gbps downstream and up to 40 Gbps upstream. The system typically deploys four (optionally eight) tunable wavelength channels in the downstream (1596–1603 nm) and upstream (1524–1544 nm) directions, with each channel operating at 10 Gbps and supporting dynamic load balancing across wavelengths via wavelength tunability at both the optical line terminal (OLT) and ONUs. This flexibility allows traffic to be redistributed in real-time to optimize utilization, coexistence with legacy GPON systems through wavelength partitioning, and enhanced power budgeting for reaches up to 40 km. Hybrid TDM/WDM PON architectures integrate TDM sub-channels onto multiple WDM wavelengths, scaling beyond single-wavelength limits while preserving compatibility with existing . In these systems, the OLT transmits TDM-multiplexed bursts on each of several WDM channels, with ONUs selecting specific wavelengths via tunable filters, enabling aggregate rates like 25 Gbps or 50 Gbps per fiber. For instance, early designs overlay 10 Gbps TDM PONs across four WDM channels, achieving 40 Gbps total while supporting longer reaches (up to 60 km) through reduced splitter losses compared to pure TDM. These WDM and hybrid PON variants offer significant advantages, including multi-gigabit per-user speeds up to 40 Gbps aggregate, lower latency from dedicated or balanced channel access, and improved scalability for dense urban deployments serving business and residential users. However, challenges include maintaining wavelength stability against temperature drifts and laser linewidth broadening, which can degrade signal quality over distance, necessitating advanced tunable components and forward error correction. Costly colorless optics and the need for precise channel coordination further complicate widespread adoption, though ongoing refinements in laser technology mitigate these issues. Recent advancements include extensions to 50G-PON TWDM systems, formalized in ITU-T G.9804.3 Amendment 2 (2024), which support 50 Gbps per channel across up to eight wavelengths for 400 Gbps aggregate, with backward compatibility to via flexible rates (25G/50G). These developments enable trials and initial commercial deployments as of 2025, such as the first service launch in the UK by Netomnia and in May 2025, addressing surging bandwidth demands from backhaul and 8K video, while incorporating enhanced modulation formats like PAM4 for .

Specialized and Emerging Variants

DOCSIS Provisioning of EPON (DPoE) enables the integration of services over Ethernet Passive Optical Networks (EPON) by leveraging existing provisioning and operations support systems, allowing cable operators to extend hybrid fiber-coax architectures into fiber-deep deployments. Developed by CableLabs in collaboration with operators and vendors, DPoE version 2.0 specifications, released in 2018, define the architecture for -based IP services over EPON, including mappings to standards for functionality and support for up to 1.25 Gbps symmetric rates. This approach facilitates scalable interfaces for provisioning EPON devices while maintaining compatibility with legacy equipment, particularly in multi-system operator environments seeking to upgrade coax networks without full replacement. RF over Glass (RFoG) provides an analog overlay for video services on PON infrastructures, transmitting radio frequency (RF) signals directly over to support legacy distribution alongside digital PON data. Standardized by the Society of Cable Telecommunications Engineers (SCTE) in SCTE 174 2010 (with extensions in 2018), RFoG operates by modulating downstream RF video signals onto a 1550 nm optical carrier and upstream return path signals at 1310 nm or 1610 nm, enabling coexistence with or EPON on the same fiber without interference. This variant is optimized for fiber-to-the-home extensions where passive splitting up to 32 ways preserves the 750 MHz RF spectrum for QAM video delivery, offering a cost-effective bridge for operators transitioning from coax while achieving optical power budgets suitable for 20 km reaches. Long-reach PON extends the typical 20 reach to over 100 , primarily through optical and low-loss fibers, targeting rural and underserved areas to reduce central office requirements and consolidate access networks. Prototypes demonstrate high-speed over extended distances using optical amplifiers (SOAs) placed at remote nodes for bidirectional gain, achieving budgets exceeding 31 dB loss with 1024-way splits while maintaining bit error rates below 10^{-12}. For instance, 112.5 Gbit/s over 50 has been achieved using SOAs. These designs leverage ultra-low-loss fibers with 0.17 dB/ attenuation to enable purely passive architectures over extended distances, though challenges like and limit upstream performance without additional equalization. Among emerging variants, the ca-2020 standard introduces 25G/50G EPON, supporting symmetric 25 Gb/s or 50 Gb/s per lambda over existing single-mode fiber infrastructures with 20 km reaches and 1:128 splits, using two wavelengths (1577 nm downstream, 1270 nm upstream for 25G; additional 1330 nm for 50G asymmetric). This amendment to enhances TDM-PON capacity for evolution, incorporating and burst-mode receivers to handle high-speed upstream contention while backward-compatible with optics. Deployments are anticipated to accelerate multi-gigabit services, with interoperability specifications ensuring seamless upgrades in operator networks. XGS-PON integration with fronthaul supports centralized radio access networks (C-RAN) by providing low-latency, high-capacity transport for eCPRI interfaces, where dynamic bandwidth allocation () algorithms adapt to stringent 100 μs round-trip requirements over shared PON upstreams. Research demonstrates traffic-estimation-based achieving upstream delays under 50 μs for 10 Gb/s symmetric XGS-PON in mobile fronthaul, enabling up to 128 per OLT with option 7.x mapping for efficient Ethernet framing of signals. Hybrid schemes combining immediate allocation for constant traffic and credit-based granting further reduce to below 1 μs, facilitating PON as a cost-effective alternative to dedicated dark fiber in urban deployments. Quantum-secure PON pilots explore integration of (QKD) for post-quantum in access networks, leveraging existing fiber to distribute secure keys alongside classical data channels. Post-2023 demonstrations include OFDM-based QKD over PON-like architectures achieving 100 km reaches with secure key rates of 1 Mbps at 12.8 Gbaud, using to separate quantum (C-band) and classical (O-band) signals while mitigating Raman noise. These pilots, often in collaboration with standards bodies, address vulnerabilities in PONs by enabling unconditional security for fronthaul , though scalability to multi-user splits remains limited by photon detection . For readiness, PON variants incorporate integrations to support ultra-low and distributed processing, with high-split PONs (HS-PON) enabling flexible resource pooling at the network edge. Studies propose -driven DBA in 50G-PON for fronthaul, reducing end-to-end by 47% through edge-cached computations and dynamic allocation, while integrating with (MEC) for real-time analytics in ecosystems. This evolution positions PON as a backbone for optical access, combining terabit capacities with edge intelligence to handle backhaul demands in dense urban scenarios.

Applications and Deployments

Fiber to the Premises

Fiber to the Premises (FTTP), also known as Fiber to the Home (FTTH) for residential applications, delivers directly to end-user locations, leveraging passive optical network (PON) technology to enable shared infrastructure while maintaining high performance. The optical distribution network (ODN) in FTTP architectures typically follows a point-to-multipoint topology, where a single feeder fiber from the central branches out via passive optical splitters to serve multiple . Common splitter ratios include 1:32 for residential single-family units, supporting up to 32 optical network terminals (ONTs) over distances up to 20 km with insertion losses of 20-29 , depending on the power budget class. This design minimizes active components in the , reducing maintenance and enhancing reliability. In multi-dwelling units (MDUs) and commercial buildings, FTTP ODN designs incorporate distributed or centralized splitting to accommodate higher density. For MDUs, such as apartment complexes, splitters are often installed at the building entry point or in dedicated cabinets, allowing a single incoming fiber to fan out to 32-128 units per splitter stage, with cascaded configurations (e.g., 1:4 followed by 1:8) for scalability. Commercial premises may use similar setups but with adjusted ratios, like 1:16, to prioritize lower and higher per user. These architectures reuse standard single-mode fiber ( G.652) and passive components, ensuring compatibility with existing PON deployments without requiring ODN modifications. FTTP deployment models vary between greenfield builds, which involve constructing new in undeveloped or rural areas for optimal routing and lower disruption, and overbuilds, where is overlaid on existing or networks in urban settings to accelerate rollout. Typical costs range from $700 to $1,000 per home passed, influenced by factors like aerial versus underground installation, with underground methods increasing expenses due to trenching (median $18.25 per foot in 2024 surveys). approaches often achieve lower per-home costs through planned routing, while overbuilds face higher challenges from permitting and coordination but enable faster market entry. As of mid-2025, global FTTH adoption has surpassed 1.1 billion connected homes, with homes passed exceeding 1 billion worldwide, driven primarily by where leads with over 600 million fiber connections and 93.6% penetration rate. has pioneered 50G PON pilots, capturing 93% of global commercial deployments in 2024-2025 to support ultra-high-speed scaling. The PON topology's passive nature facilitates this widespread rollout by efficiently sharing feeder fibers across dense populations. FTTP enables triple-play services—integrating , video, and high-speed data—delivering symmetrical bandwidths of 1-10 Gbps to support simultaneous streaming, VoIP calls, and multi-device connectivity without congestion. These speeds, enabled by standards like XGS-PON (10 Gbps downstream), outperform legacy copper technologies, reducing to under 5 ms and enhancing for bandwidth-intensive applications.

Integration with Broadband Ecosystems

Passive optical networks (PONs) integrate seamlessly with broader ecosystems by serving as high-capacity transport layers that connect fixed and mobile infrastructures, enabling efficient of services across diverse technologies. This integration leverages PON's symmetrical bandwidth and low-latency characteristics to support unified network architectures, reducing operational costs and enhancing scalability for operators deploying multi-gigabit services. In wireless backhaul applications, PONs provide robust transport for and emerging networks, particularly for and high-frequency bands. XGS-PON, offering 10 Gb/s symmetrical speeds, is widely used to backhaul , allowing operators like to converge residential and mobile services on a single fiber infrastructure, which cuts transport costs by up to 50%. For mmWave deployments requiring ultra-high , 50G PON variants deliver the necessary for dense urban aggregation, as demonstrated in field trials connecting multiple base stations with low latency. Looking toward , PONs enable virtualized optical-wireless heterogeneous networks by integrating passive optical distribution with radio access, supporting medium- and long-haul transport for distributed in beyond-5G scenarios. Convergence with legacy cable and DSL infrastructures occurs through hybrid architectures that overlay PON onto existing coaxial or copper plants, facilitating gradual migrations without full rip-and-replace. In hybrid fiber-coax (HFC) networks, can utilize pre-existing poles, conduits, and dark fibers from systems, with optical line terminals (OLTs) installed to distribute services via splitters in legacy cabinets, enabling operators to deliver gigabit speeds over coaxial drops during transition phases. This approach, supported by platforms like Harmonic's cOS, allows simultaneous operation of and PON technologies, maximizing asset utilization while upgrading to fiber-to-the-anything models for multiple system operators (MSOs). Such integrations address limitations in traditional DSL by providing a scalable path to symmetrical multi-gigabit access. The enablement of (SDN) and (NFV) in PON ecosystems introduces programmable OLTs that support dynamic service orchestration. In SDN-enabled broadband access (SEBA) architectures, OLTs are abstracted as virtual Ethernet switches, allowing external controllers to manage dynamic allocation and steering via protocols like , which decomposes traditional PON functions for flexible multi-tenant deployments. NFV integration with time- and PONs (TWDM-PONs) further enables virtual network functions (VNFs) for service chaining, such as and QoS enforcement at , reducing provisioning times and supporting on-demand slicing for diverse applications. This programmability enhances PON adaptability in converged networks, with OLTs handling real-time reconfiguration for varying loads. Post-2020 developments have emphasized PON's role in smart cities and edge computing, where high-speed optical access addresses connectivity gaps in distributed sensor networks and real-time analytics. Projects like GENIO integrate PON with (MEC) to provide low-latency backhaul for devices in urban environments, enabling seamless data flows for applications such as and . In sustainable frameworks, PONs support AI-driven resource allocation over optical access networks, enhancing scalability for massive deployments while minimizing energy use through efficient fiber sharing. These integrations, often combined with , facilitate end-to-end ecosystems for edge-processed services, as seen in analyses of high-speed PON-enabled city infrastructures.

Security and Performance

Security Measures

Passive optical networks (PONs) implement as a primary defense against , particularly in the downstream direction where traffic is broadcast to all optical network units (ONUs). standards mandate AES-128 for user data, while Ethernet PON (EPON) standards support AES-128 optionally, ensuring that only authorized ONUs can decrypt the content using pre-shared or dynamically exchanged keys. This protects against unauthorized interception by rogue devices connected to the same splitter. In contrast, older Broadband PON (BPON) systems treat AES as optional, relying instead on basic that offers limited protection against sophisticated attacks. In PONs such as , key management and are facilitated through the ONU Management and Control Interface (OMCI), which enables secure provisioning and mutual between the optical line terminal (OLT) and ONUs. OMCI protocols support the exchange of encryption keys following initial , preventing man-in-the-middle attacks during network activation. Additionally, Operations, Administration, and Maintenance (PLOAM) messages provide low-level mechanisms, such as serial number-based ONU identification, to ensure only legitimate devices participate in the network. At the , separation between upstream and downstream signals inherently bolsters ; downstream broadcasts on one are encryptable, while upstream (TDMA) on a different resists casual sniffing without dedicated tuned to that band. However, passive optical splitters introduce vulnerabilities, as attackers with physical access can insert taps to divert a fraction of the and capture unencrypted or weakly protected signals across wavelengths. Emerging advanced techniques include post-2020 trials integrating (QKD) into PON architectures, leveraging the existing fiber infrastructure for distributing quantum-secure keys in point-to-multipoint setups. These experiments demonstrate compatibility with classical PON traffic via wavelength multiplexing, achieving secret key rates over distances typical of access networks while addressing threats to classical . Recent standards, such as ITU-T G Supplement 81 (2024) on PON security practices and amendments to G.988 for enhanced OMCI security features, incorporate updated threat models and countermeasures like improved protocols to mitigate evolving cyber risks.

Challenges and Optimizations

Passive optical networks () face several operational challenges stemming from the physical properties of and deployment economics. Optical fibers used in PONs are inherently fragile, susceptible to mechanical damage from bending, crushing, or environmental stress, which can lead to signal or complete link failure during or maintenance. High (CAPEX) poses a significant barrier in rural deployments, where low increases the cost per user for trenching and laying, often exceeding potential without subsidies. Additionally, older PON systems like exhibit upstream asymmetry, with typical rates of 1.25 Gbps upstream compared to 2.5 Gbps downstream, limiting performance for bandwidth-intensive applications. To mitigate transmission errors exacerbated by fiber imperfections or long distances, PON standards incorporate (FEC) mechanisms, such as the Reed-Solomon (255,239) code in , which adds 16 parity bytes to correct up to 8 symbol errors per block and is optionally applied to upstream for improved reliability. Power saving modes further address energy consumption in ; for instance, sleep and doze modes in and EPON reduce power by deactivating non-essential components during idle periods, potentially saving up to 50% of energy without compromising . Emerging AI-based approaches, including models like (LSTM) networks, enable proactive fault prediction by analyzing historical (OTDR) traces and performance metrics, achieving over 95% accuracy in forecasting fiber faults hours in advance. Scalability in long-reach , which extend coverage to over 100 and support split ratios exceeding 1:128 to serve thousands of users, encounters challenges in dynamic allocation () and power budgeting to handle 10,000+ subscribers without excessive or signal degradation. Solutions like schemes, including 1+1 and multi-chassis PON architectures, enhance reliability by isolating faulty and rerouting traffic in under 50 , thereby supporting higher user densities in consolidated networks. Recent advancements in PON standards emphasize through enhanced for green networks. Post-2022 developments in 50G-EPON and 50G-PON (G.9804) incorporate (SLA)-aware dynamic bandwidth and wavelength allocation (DBWA) algorithms, enabling significant reductions in ONU power consumption during low-traffic scenarios while maintaining multi-gigabit speeds. These optimizations align with ITU-T supplements on power conservation, prioritizing low-power transceivers and adaptive rate selection to minimize the of access infrastructure.

References

  1. [1]
    What is a passive optical network (PON) and how does it work?
    Jul 20, 2021 · A passive optical network (PON) is a system commonly used by telecommunications network providers that brings fiber optic cabling and signals all or most of ...
  2. [2]
    [PDF] Recent progress in ITU-T PON standards
    Passive Optical Network (PON) system is a point-to-multipoint optical communication sytem. Multiple (e.g. 16 to 128) ONUs comminicate with an OLT via optical ...
  3. [3]
    [PDF] Ethernet Passive Optical Network (EPON) A Tutorial
    EPON can support downstream broadcast such as video. The IEEE 802.3ah EPON specification defines Multi-. Point Control Protocol (MPCP), Point-to-Point.
  4. [4]
    IEEE 802.3ca-2020
    Jul 3, 2020 · This amendment to IEEE Std 802.3-2018 extends the operation of Ethernet passive optical networks (EPONs) to multiple channels of 25 Gb/s.
  5. [5]
    None
    ### Summary of Passive Optical Network (PON) Fundamentals
  6. [6]
    FTTH PON: Passive Optical Network - The Fiber Optic Association
    Downstream digital signals from the CO through the splitter to the home are sent at 1490 nm. ... ITU-T G.983, ITU-T G.984, IEEE 802.3ah (1 Gb/s) IEEE 802.3av ( ...
  7. [7]
    EPON/GPON to 10G PON, NG-PON2 & 25G/50G PON - FS.com
    Feb 9, 2025 · To meet this demand, XGS-PON was introduced, providing symmetric 10 Gbps upstream and downstream bandwidth, completing the 10G PON upgrade.
  8. [8]
    What is the Difference Between a PON and an Active Optical Network?
    Power usage and efficiency: PONs use unpowered optical splitters, making them more energy-efficient and cost-effective. AONs require powered devices like ...Key Takeaways · Passive Optical Network (PON) · Active Optical Network (AON)
  9. [9]
    GPON power budget calculations - APNIC Blog
    Nov 14, 2024 · Gigabit Passive Optical Network (GPON) is based on the ITU-T G.984.x standards and typically allows 64 to 128 splits with an approximate reach ...
  10. [10]
  11. [11]
    A Comprehensive Guide To GPON And EPON Technologies In PON ...
    Dec 5, 2023 · Transmission Distance and Split Ratio, The maximum transmission distance of GPON can reach 20 kilometers, and the maximum split ratio is 1:128 ...<|control11|><|separator|>
  12. [12]
    Passive Optical Network Tutorial - FS.com
    Jul 10, 2024 · Passive optical networks possess superior advantages with respect to speed, energy consumption, reliability, and the cost of deployment can ...Missing: disadvantages | Show results with:disadvantages
  13. [13]
  14. [14]
    GPON - How It Works, its Components, Benefits & Drawbacks
    Jun 9, 2022 · GPON is a leading standard of Passive Optical Network (PON) – a type of point-to-multipoint network technology that delivers broadband access to the end user ...<|separator|>
  15. [15]
    AON vs PON: Understanding the Differences in Optical Networks
    Jun 3, 2025 · PON is more energy-efficient. Its passive components require no power, reducing energy consumption. AON, on the other hand, relies on powered ...
  16. [16]
    Passive Optical Networks Progress: A Tutorial - MDPI
    The first idea about the use of completely passive technology was presented in 1980s, when a tree topology was considered for telephony services [11]. The TDMA ...
  17. [17]
    Origins of the Erbium-Doped Fiber Amplifier - Optica Publishing Group
    Optical amplification in lightwave systems became practical with the invention of the Erbium-doped Fiber Amplifier (EDFA) in the late 1980s.
  18. [18]
    THE WIRING OF BRITAIN: BRITISH TELECOM STARTS TRIAL OF ...
    Apr 27, 1989 · The BIDS project will start in March 1990 with TPON following in September 1990 and being upgraded to BPON in March 1991; British Telecom says ...Missing: field | Show results with:field
  19. [19]
    FSAN | Full Service Access Network
    First established by seven telecommunication operators in 1995 for the purpose of formulating the minimum requirement set for the optical transceivers in the ...FSAN Roadmap · FSAN Participants · FSAN Governing documents · Contact
  20. [20]
    G.983.1 : Broadband optical access systems based on Passive ... - ITU
    Nov 4, 2019 · G.983.1 is a recommendation for broadband optical access systems based on Passive Optical Networks (PON).
  21. [21]
  22. [22]
    IEEE 802.3ah-2004 - IEEE SA
    IEEE 802.3ah-2004 is an amendment for subscriber access networks, combining MAC extensions with physical layers, including optical fiber and copper, and ...
  23. [23]
    IEEE 802.3av-2009 - IEEE SA
    This amendment to IEEE Std 802.3-2008 extends Ethernet Passive Optical Networks (EPONs) operation to 10 Gb/s providing both symmetric, 10 Gb/s downstream and ...
  24. [24]
    Guide to Optical Line Terminal (OLT) Classifications: Detailed Types ...
    Sep 28, 2024 · In modern communication networks, optical line terminal (OLT) is the core device to realize point-to-multipoint(P2MP) in passive optical ...
  25. [25]
    Understand GPON Technology - Cisco
    This document describes the Gigabit Passive Optical Network (GPON) technology and how it functions.
  26. [26]
    Decoding OLT, ONU, ONT, and ODN in PON Network - FS.com
    Mar 14, 2023 · OLT is short for optical line terminal, which is a device used to connect olt fiber and transfer signals. PON OLT is the starting point, which ...
  27. [27]
    Understanding OLT, ONU, ONT, and ODN in PON - C-Data
    Nov 15, 2023 · ONUs convert optical signals transmitted through fiber optics into electrical signals. These electrical signals are then sent to individual ...
  28. [28]
    [PDF] PASSIVE OPTICAL SPLITTER - SENKO Advanced Components
    The most common splitters deployed in a GPON system are uniform power splitters with a 1xN or 2xN splitting ratio, where N is the number of output ports ...Missing: placement | Show results with:placement
  29. [29]
    How to Design Your FTTH Network Splitting Level and Ratio
    Sep 2, 2019 · The most common optical splitters deployed in a PON system is a uniform power splitter with a 1:N or 2:N splitting ratio (N=2~64), where N is the number of ...
  30. [30]
    Virtual Optical Line Terminal (vOLT) Concepts - Accton Technology
    Apr 30, 2024 · A vOLT is an open, disaggregated appliance that creates an OLT for SDN/NFV environments, using any manufacturer's 'white-box' OLT.Missing: evolution | Show results with:evolution
  31. [31]
    Software Enabled Broadband Access (SEBA) Solution Overview
    In a SEBA Pod, the OLT and ONU are controlled by VOLTHA (Virtual OLT Hardware Abstraction) instead of a traditional OLT. VOLTHA is a project that provides a ...
  32. [32]
    Cloud-Powered PON | SDN and NFV - Broadband Library
    Cloud-powered PON uses SDN and NFV, with a cloud-based SDN controller, to enable centralized control, virtualized functions, and reduce hardware needs.
  33. [33]
    Fundamentals of Optical Splitters
    Optical splitters are passive devices that split a single optical signal into multiple signals or combine multiple signals into a single one. As passive devices ...
  34. [34]
    Basic Knowledge about Split Ratio and Insertion Loss of Optical ...
    Mar 2, 2024 · In this article, you will learn the basic knowledge about split ratio and insertion loss of optical splitter. Optical Splitter Overview. Optical ...Missing: characteristics wavelength independence
  35. [35]
    10-Gigabit Optical Networks Boost China's Fiber Tech - HTF DWDM
    Apr 8, 2025 · High-speed transmission increases sensitivity to fiber loss, necessitating low-loss ... 50G-PON with more efficient terminals and splitters.<|control11|><|separator|>
  36. [36]
    Reference to Insertion Loss and Return Loss for Fiber Connectors
    Apr 12, 2021 · When measuring the attenuation effects of the fiber connectors ... Usually, the insertion loss of PC, UPC, and APC connectors is less than 0.3dB.
  37. [37]
    Guidelines On What Loss To Expect When Testing Fiber Optic Cables
    For each connector, we usually figure 0.3 dB loss for most adhesive/polish or fusion splice-on connectors. · When testing cable plants per OFSTP-14 (double ended) ...Missing: PON | Show results with:PON
  38. [38]
    Full Guide of PON: OLT, ONT, ONU, ODN and other basic components
    Jul 24, 2023 · The ODN is divided into five sections: feeder fiber, distribution point, distribution fiber, access point, and drop fiber.
  39. [39]
    [PDF] DBA (Dynamic Bandwidth Allocation) Overview - IEEE 802
    DBA dynamically changes upstream bandwidth on a millisecond/microsecond timescale, improving PON bandwidth efficiency by adjusting bandwidth among ONUs.
  40. [40]
    [PDF] ITU-T Rec. G.984.3
    Oct 27, 2005 · Dynamic bandwidth allocation signaling and configuration. ○ All OLTs provide traffic monitoring DBA, so that ONUs that do not report status can.
  41. [41]
    Review on dynamic bandwidth allocation of GPON and EPON
    The GPON standard is defined in ITU-T G. 984. x [14]. The data rates for downstream and upstream are 2.488 Gbps and 1.244 Gbps, respectively.
  42. [42]
    [PDF] Request-based Dynamic Bandwidth Allocation of Gigabit Passive ...
    Fixed and assured bandwidth is guaranteed bandwidth while non-assured bandwidth and best-effort bandwidth is surplus bandwidth. Critical values include maximum ...
  43. [43]
    [PDF] Evaluation of Dynamic Bandwidth Allocation Algorithms in GPON ...
    Non-assured and best effort traffic grants are not served in strictly regular intervals. ... In order to ensure lowest delays for assured and non-assured traffic ...
  44. [44]
    [PDF] Research and improvement of GPON dynamic bandwidth allocation ...
    An excellent DBA algorithm is required to track the changes in data traffic, as required. If the distribution value is too large, it will cause bandwidth waste, ...
  45. [45]
    A Dynamic Bandwidth Allocation Scheme for GPON Based on Traffic ...
    Oct 20, 2025 · Two novel dynamic bandwidth allocation (DBA) algorithms (LLR and LWR) based on bandwidth debit and credit were proposed to solve the problem of ...Missing: modes | Show results with:modes
  46. [46]
    GPON vs EPON: Comparison of Passive Optical Network ...
    Oct 27, 2025 · In terms of effective bandwidth, GPON achieves up to 92% utilization due to GEM's efficient framing, compared to EPON's 70-80% with Ethernet ...
  47. [47]
    (PDF) Deep Learning-Based Dynamic Bandwidth Allocation for ...
    In this paper, we propose a novel DBA approach that employs deep learning to predict the bandwidth demand of end-users so that the control overhead due to the ...
  48. [48]
    Machine learning enhanced next-generation optical access ...
    Jan 9, 2023 · Finally, we consider a fast and self-adaptive machine learning enhanced dynamic bandwidth allocation scheme in an illustrative future use case ...
  49. [49]
    [PDF] Intelligent Bandwidth Allocation in PON by using Machine Learning ...
    In generally, dynamic bandwidth allocation (DBA) is used in PON to allocate traffic bandwidth in upstream based on the demands and requests from users (ONUs).
  50. [50]
  51. [51]
    [PDF] GPON
    Since it was a first attempt at a PON standard it has 2 major weaknesses: is ... 984.3 specifying the G-PON transmission convergence (TC) layer was ratified ...<|separator|>
  52. [52]
    GPON vs. XG PON vs. XGS PON: Which PON Technology Is Right ...
    Jan 19, 2024 · For instance, GPON utilizes an upstream wavelength of 1310nm and a downstream wavelength of 1490nm. ... ITU-T G.984 and G.988 respectively ...
  53. [53]
    EPON VS GPON. A passive optical network (PON) is a… - Medium
    Sep 4, 2015 · EPON uses an advanced encryption standard (AES) based mechanism ... GPON encryption is downstream only. All in all, both EPON and GPON ...<|separator|>
  54. [54]
    IEEE 802.3™ Industry Connections Feasibilty Assessment for the ...
    Mar 13, 2015 · A WDM-PON provides each ONU (and subscriber(s) connected to such an ONU) with at least one dedicated pair of wavelength channels (one downstream ...
  55. [55]
  56. [56]
    Architecture design and key technologies for hybrid TDM/WDM ...
    Hybrid TDM/WDM PON is a promising optical access network solution which taking advantages of both TDM-PON and WDM-PON, and suitable for near future ...
  57. [57]
    WDM Passive Optical Networks and Beyond: the Road Ahead [Invited]
    Each of the following WDM PON architectures addresses different important design issues of next-generation WDM PONs. 2A. Long-Reach WDM PON. As observed by ...
  58. [58]
    G.9804.3 (2021) Amd. 1 (02/2023) - ITU-T Recommendation database
    Feb 22, 2023 · Recommendation ITU-T G.9804.3 describes a 50-Gigabit-capable passive optical network (50G PON) system in an optical access network for ...
  59. [59]
    [PDF] ITU-T SG15 Standards Update
    Mar 27, 2024 · TWDM-PON. << First multi-wavelength PON standard. • G.9804 50G-PON ... Global 50G-PON Field test by 2023. Remote test. Field test. Region.
  60. [60]
    DPoE™ - CableLabs
    DOCSIS® Provisioning of EPON (DPoE™) Specifications create an architecture and serve as necessary specifications for enabling Ethernet Passive Optical.
  61. [61]
    [PDF] DOCSIS® Provisioning of EPON Specifications DPoEv2.0 DPoE ...
    Mar 22, 2023 · DOCSIS Provisioning of EPON (DPoE) version 2.0 specifications are a joint effort of Cable Television Laboratories. (CableLabs), cable operators, ...
  62. [62]
    Radio Frequency over Glass Fiber-to-the-Home (RFoG ... - Log In
    ... SCTE 174 2018 (R2024). Radio Frequency over Glass Fiber-to-the-Home (RFoG) Specification Extension. This document defines a fiber-to-the-home system optimized ...Missing: PON | Show results with:PON
  63. [63]
    CommScope Commends SCTE for Adopting Official RFoG ...
    At the end of 2010, the SCTE published SCTE 174 2010, which officially standardized all RFoG devices, and CommScope played a vital role in the specification's ...
  64. [64]
    21 Gb/s after 100 km OFDM long-reach PON transmission using a ...
    In this work, we experimentally demonstrate optical DSB-OFDM transmission over 100-km single-mode fiber (SMF) link using a cost-effective 10-GHz bandwidth ...
  65. [65]
    112.5 Gbit/s long reach passive optical network with over 31 dB ...
    Jul 29, 2025 · The proposed architecture utilizes the optical signal amplification mechanism by placing an SOA in the RN of the next-generation LR-PON to ...
  66. [66]
    Ultra-low-loss optical fiber enabling purely passive 10 Gb/s PON ...
    Feb 16, 2009 · The purely passive nature of the 100 km systems is enabled by the use of ultra-low-loss optical fiber with average attenuation of 0.17 dB/km and ...<|separator|>
  67. [67]
  68. [68]
    Traffic-Estimation-Based Low-Latency XGS-PON Mobile Front-Haul ...
    Jul 6, 2018 · Front-haul transport network sharing is a potential method to address C-RAN deployment cost issues in the 5G era. A variety of front-haul ...
  69. [69]
    OFDM-based quantum key distribution access network reaching ...
    Oct 16, 2025 · Quantum key distribution (QKD) can theoretically accomplish unconditionally secure communication with the support of quantum mechanics.
  70. [70]
    Toward 6G Optical Fronthaul: A Survey on Enabling Technologies ...
    Jun 1, 2024 · This survey provides an explanation of the 5G and future 6G optical fronthaul concept and presents a comprehensive overview of the current state of the art and ...<|separator|>
  71. [71]
    Optical access networks to support future 5G and 6G mobile ...
    We identify key factors such as enhanced connectivity, efficiency, and flexibility, which will be enabled by technologies including AI, edge computing, HS-PON/ ...
  72. [72]
    [PDF] FTTx PON Architecture Considerations - NCTA Technical Papers
    Up until recently, our PON distribution network was a conventional fixed 1:64 split ratio, which used a bank of optical splitters in an ODN cabinet. The two ...
  73. [73]
    The Cost of Overbuilding - POTs and PANs
    Feb 25, 2025 · ... costs are more than $3,000 per passing. For years, AT&T and Verizon touted overbuilding costs below $1,000 per passing. It seems to me that ...
  74. [74]
    Underground Fiber Deployment Most Expensive and Most Common
    Feb 6, 2025 · Typical fiber costs ranged from $10 to $27 per foot for underground and $5 to $14 for aerial deployments. · Labor costs range from 60% to 80%.
  75. [75]
    FTTH/B Global Ranking 2025 - FTTH Council Europe
    Mar 19, 2025 · The UAE leads the ranking with 99,5%, while South Korea positions itself second at 96,6%. China (93,6%), Barbados (91,4%) and Hong Kong (89,9%) ...Missing: adoption Asia 50G PON pilots
  76. [76]
    China Leads the Race in Internet Speed with 50G-PON Technology
    Feb 9, 2025 · Forecasts from Omdia indicate that China will be the sole commercial market for 50G-PON between 2024 and 2025, accounting for 93% of the global ...Missing: Asia | Show results with:Asia
  77. [77]
    Fiber-optic Cable Market Trends | Report [2033]
    Oct 13, 2025 · ... FTTH/B homes passed by early 2025. In Asia-Pacific, China alone added more than 45 million new fiber-passed premises in 2024, bringing the ...Missing: 50G PON
  78. [78]
    [PDF] developments of next generation networks (ngn): country case ... - ITU
    Dec 31, 2009 · Triple play services are widespread within residential customers whereas VoIP remains limited within the business market. Regulatory ...
  79. [79]
    Fiber for Everything | Nokia.com
    High-speed connectivity for consumer broadband, IND 4.0, smart city and 5G sites on a single fiber passive optical network (PON). Learn more.
  80. [80]
    Migration from GPON to XG(S)-PON - The Fiber Optic Association
    Some CATV service providers are converting their traditional hybrid fiber coax (HFC) networks to fiber to the home (FTTH.) Here are some of the reasons why and ...
  81. [81]
    Fiber Solutions for Cable Operators - Harmonic Inc.
    With the cOS broadband platform you can migrate to GPON, XGS-PON, Combo PON, while you maximize your existing DOCSIS network. Always ahead of the curve.Missing: DSL | Show results with:DSL
  82. [82]
    [PDF] SDN Enabled Broadband Access (SEBA)
    Mar 18, 2019 · In this architecture, these PON-specific features and devices (i.e. OLT/ONUs) are abstracted by AN Driver into a pseudo-Ethernet switch whose ...
  83. [83]
  84. [84]
    Optical-access networks for smart sustainable cities - ResearchGate
    Aug 7, 2025 · We discuss artificial intelligence-based network monitoring and resource allocation. Next, we provide a techno-economical study for sustainable ...Missing: post- | Show results with:post-
  85. [85]
    Real-World Analysis of Smart City Integrated Services using High ...
    The capabilities of networked city services have significantly increased with the development of technologies like Ethernet and passive optical network (PON).
  86. [86]
    GPON Security - Gigabyte Passive Optical Network (GPON)
    GPON uses Advanced Encryption Standard (AES) encryption to secure the data transmitted between the Optical Line Terminal (OLT) and the Optical Network Unit (ONU) ...
  87. [87]
    ITU-T Rec. G.983.1 Amendment 2 (03/2003) Broadband optical ...
    Mar 16, 2003 · As an option, the Advanced Encryption Standard (AES) may be used instead of churning to provide link security. Although there are several ...
  88. [88]
    Insight Into GPON OMCI (ONU management and control interface)
    Jun 13, 2018 · OMCI supports a mechanism that allows mutual authentication of OLT and ONU and subsequent secure communication of encryption keys. These keys ...
  89. [89]
    Fiber to the Premises – PONdering the Details - IP Infusion
    May 3, 2019 · EPON utilizes IEEE 802.3ah OAM (also known as Ethernet in the First Mile or EFM) messages for provisioning, fault isolation, and performance ...
  90. [90]
    TDM-PON Security Issues: Upstream Encryption is Needed
    In this paper, we introduce a novel passive and wavelength selective remote node specifically designed to enable security countermeasure in PONs. The ...Missing: separation sniffing
  91. [91]
    Physical Layer Components Security Risks in Optical Fiber ... - MDPI
    The major risk is the possibility of inserting a splitter into the optical distribution network and capturing a portion of the entire spectrum, i.e., all ...
  92. [92]
    Optical Link Design for Quantum Key Distribution-Integrated ... - MDPI
    In this study, we review recent advancements in both QKD and access network technologies, evaluate the technical feasibility of QKD-OAN integration,Optical Link Design For... · 3. Case Study On Qkd In P2mp... · 4.2. Cv-Qkd Implementation...
  93. [93]
    ITU-T G Suppl. 81 (07/2024) Practical aspects of PON security
    This text outlines the security considerations and enhancements for Passive Optical Networks (PONs), focusing on the threat model, operator expectations, ...Missing: 988 | Show results with:988
  94. [94]
    G.988 (2022) Amd. 2 (05/2025) - ITU-T Recommendation database
    May 14, 2025 · Recommendation ITUT G.988 specifies the optical network unit (ONU) management and control interface (OMCI) for optical access networks.Missing: extensions | Show results with:extensions
  95. [95]
    4 Limitations of Optical Fiber and How to Overcome Them
    Aug 5, 2018 · One of the most significant limitations of fiber is its fragility. Typically made of glass, fiber cables are thinner and lighter than metallic wiring.
  96. [96]
    (PDF) Modelling accurate planning of PON networks to reduce initial ...
    Deploying FTTH in rural areas is not trivial due to high initial capital expenditures, which are caused by low density of end-users and lack of ...
  97. [97]
  98. [98]
    Application of no-light fault prediction of PON based on deep ...
    Aug 1, 2023 · This paper proposes using LSTM and GRU deep learning models trained on historical data to predict no-light faults in PON ports in real-time.
  99. [99]
    Multi-Chassis Passive Optical Network (MC-PON) Protection in MPLS
    This document describes the Multi-Chassis PON (MC-PON) protection architecture in MPLS and also specifies the Inter-Chassis Communication Protocol (ICCP) ...
  100. [100]
    Power conservation in optical access systems - ITU
    In addition to GPON-initiated low-power modes, other power-saving modes have been made possible through the specification of multiple line rate options that ...