A goniometer is a device that measures an or permits the of an object to a definite position. Commonly employed in scientific and medical fields, it typically consists of two rigid arms connected at a , often with a protractor-like scale for precise angular readings. The origins of the goniometer trace back to the 16th century, when Dutch physician and mathematician Gemma Frisius described a primitive version based on the astrolabe for measuring angles. The modern contact goniometer, designed for direct measurement of crystal faces, was invented by French mineralogist Arnould Carangeot in 1780. Subsequent refinements, such as William Hyde Wollaston's 1809 model with a vertical circle and telescope, enhanced accuracy for crystallographic applications, evolving into more complex three-circle instruments by the mid-19th century. Goniometer use in crystallography declined with the advent of X-ray diffraction techniques in the 20th century, though it remains relevant in specialized contexts. In and , goniometers are essential tools for assessing (ROM), aiding physical therapists and clinicians in evaluating , diagnosing impairments, and tracking treatment progress. Standard universal goniometers feature 180- or 360-degree scales and are handheld for non-invasive measurements of like the or . and smartphone-based goniometer applications have emerged as reliable alternatives, offering improved efficiency and validity comparable to traditional models, particularly for dynamic assessments like ; as of 2025, advancements include AI-driven video-based systems and wireless wearable sleeves. Beyond healthcare, goniometers serve in to determine crystal symmetry by measuring interfacial angles, in for evaluating facet precision on cut stones, and in or for positioning samples with nanometer accuracy in experiments.

Introduction

Definition

A goniometer is an instrument designed to measure or to an object at a precise orientation. The term derives from the Greek words gōnía, meaning "," and métron, meaning "measure." Its primary functions include determining the between two planes or lines and enabling controlled rotation for applications requiring exact placement. Goniometers typically measure in units such as degrees (with a full circle as 360°), radians (with a as 2π), or grads (also known as gons, with a full circle as gon). Basic components consist of a for reading the angle, a or at the , and one or more arms or pointers that align with the lines or planes being measured. While related to tools like protractors, which represent a specific, simple type of goniometer for planar angles, goniometers encompass broader designs for diverse uses. In contrast, clinometers are specialized for measuring inclination relative to the horizontal, differing from the general measurement capability of goniometers.

History

The goniometer traces its origins to ancient astronomical instruments like the , which were employed for measuring angles in celestial observations as early as the , predating the . These devices facilitated precise determinations essential for and star positioning, laying foundational principles for later angle-measuring tools. The first formal description of a dedicated goniometer appeared in 1538, when Flemish mathematician and instrument maker Gemma Frisius adapted mechanisms to create an instrument specifically for terrestrial angle measurement. Frisius's design emphasized portability and accuracy, marking a shift from purely astronomical applications to broader geometric uses. In the 18th and 19th centuries, goniometers advanced significantly through their integration into . The contact goniometer, designed for direct measurement of angles between crystal faces, was invented by French mineralogist Arnould Carangeot in 1783. French mineralogist René Just Haüy employed early contact goniometers in his 1801 Traité de Minéralogie to measure interplanar angles in crystals, establishing geometric as a rigorous . Shortly thereafter, in 1809, English and invented the reflecting goniometer, which used light reflection off crystal faces to achieve higher precision on irregular surfaces, revolutionizing measurements in . The saw goniometers adapted for military purposes, with the Royal Artillery introducing the Mils Protractor in the as a semi-circular graduated in milliradians for artillery ranging and fire control. Similarly, the U.S. Army issued Graphic Training Aid GTA 5-2-12 in 1981, a coordinate scale and protractor designed for map reading and angular plotting in tactical operations. By the late , goniometers evolved to incorporate electronic sensors, with early models emerging in the , such as the patent for a goniometer by Alexander M. Voutsas in 1965, enabling automated angle readout for enhanced accuracy in scientific and industrial settings.

Types

Protractor Goniometers

Protractor goniometers are mechanical instruments designed for analog measurement, consisting of a circular or semicircular protractor graduated in degrees, paired with a pivoting that aligns along the lines forming the . The typically spans 180° or 360°, allowing the user to read the directly where the intersects the markings. For greater precision, many models incorporate a , enabling readings to within 5 arcminutes (approximately 1/12 degree) by comparing aligned graduations on the and main . Key variants expand functionality beyond basic planar measurements. The universal bevel protractor features a slotted dial that holds interchangeable or adjustable blades, permitting the measurement and scribing of angles in three dimensions, such as dihedral angles between surfaces. In contrast, the sliding bevel protractor, often configured as a T-bevel, includes a movable blade that locks at any angle via a wingnut or clamp, ideal for transferring and replicating adjustable angles in applications like or . Construction materials emphasize durability and visibility, with bodies and arms commonly made from or for robustness in professional settings, while plastic variants offer lightweight alternatives for educational or portable use. Scales are engraved or etched directly onto the metal surface to prevent fading, ensuring long-term legibility under varied lighting conditions. These devices excel in affordability and portability, requiring no power source and fitting easily into toolkits for on-site measurements in fields like or . However, their reliance on manual alignment and visual interpolation introduces limitations, including inter-observer variability and reading errors that can reach up to 5° in less precise models. Historically, subtypes known as mils protractors emerged for topographic applications, featuring dual scales in degrees and mils—a where 6400 mils correspond to 360°—to compute azimuths for and targeting. These tools, integral to U.S. Army and Marine Corps since the early , overlay on maps to plot back azimuths and coordinates with minimal .

Optical Goniometers

Optical goniometers employ light-based techniques to measure angles with high precision, distinguishing them from mechanical counterparts by enabling non-contact assessments, particularly in and . The seminal reflecting goniometer, invented by in 1809, utilizes the reflective properties of faces to determine interfacial angles. In this design, a beam of light is directed toward a mounted on a rotating stage, where the crystal's faces act as mirrors to reflect the light onto a fixed graduated scale; the angle is read directly from the scale's position as the stage rotates to align successive reflections. This innovation allowed for accurate measurement of crystal symmetries without direct mechanical contact, revolutionizing mineralogical analysis. Modern optical goniometers build on this foundation with advanced variants tailored for specific applications. Goniophotometers, for instance, measure the angular distribution of from sources such as LEDs and luminaires by rotating the sample relative to a detector while illuminating it with a . These instruments capture far-field patterns to assess beam uniformity and efficiency in . Similarly, contact angle goniometers evaluate surface wettability by analyzing the shape of a droplet on a solid through optical imaging, quantifying the angle at the three-phase contact line to infer material properties like hydrophobicity. Key components of optical goniometers include a to produce a light beam, a or high-resolution camera for precise observation of reflections or images, and a motorized rotating stage to incrementally adjust the sample . sources such as lasers or LEDs enhance , achieving sub-degree accuracy—often down to 0.1°—through electronic encoding and automated alignment, far surpassing manual methods in repeatability for delicate samples. In , optical goniometers are instrumental for measuring beam deviation in prisms and lenses, where they quantify refractive errors by tracking light path shifts with arc-second resolution, aiding in the of optical components.

Digital and Positioning Goniometers

Digital and positioning goniometers represent advanced iterations of angle-measuring devices that incorporate electronic components for automated control, precise positioning, and digital data output, enabling applications in settings, diagnostics, and automated systems. These instruments typically feature motorized mechanisms driven by motors or servo motors, often paired with worm gear drives for smooth, backlash-free motion, and optical or magnetic encoders to track angular positions with . Outputs are commonly provided via LCD displays for direct readout or USB interfaces for with computers and software, facilitating logging and . In positioning goniometers, designed primarily for environments such as and materials testing, the stages allow for controlled about a fixed , often with travel ranges of ±10° to ±30° and center heights up to 105 mm to accommodate samples. These devices employ high-resolution encoders and direct-drive or worm-gear systems to achieve angular resolutions as fine as 18 arcseconds in , making them suitable for aligning components in precision experiments like or . For instance, models like the AK170-24 series integrate stepper motors with limit switches for safe operation, supporting loads up to several kilograms while maintaining positional accuracy over repeated cycles. Digital advancements have expanded accessibility through portable and integrated solutions, including applications developed post-2010 that leverage built-in to measure angles without dedicated hardware. The knee goniometer app, for example, uses data to calculate knee flexion and extension by placing the along the limb, achieving a of 0.947 with conventional goniometers. These apps enable one-handed use and progress tracking, often integrating with systems for comprehensive kinematic analysis in or . Additionally, dedicated digital goniometers, such as those based on magnetic encoders like the AS5040, provide contactless in orthotic devices, outputting data via microprocessors for static and dynamic position tracking with resolutions around 0.35 degrees. Precision in these goniometers routinely reaches 0.1 degrees or better, enhanced by software routines that correct for gravitational offsets, sensor drift, or environmental factors, ensuring reliability across orientations. In positioning stages, resolutions extend to microradians through encoder loops, while digital variants achieve sub-degree accuracy via algorithmic adjustments in apps or embedded systems. Post-2020 developments have addressed limitations in error-prone manual measurements by incorporating for assisted correction, particularly in devices; for example, AI-driven video-based goniometers like DETROM use for pose estimation to measure with coefficients of 0.98 for flexion, enabling noninvasive, remote monitoring that reduces variability in clinical assessments. These innovations improve functional recovery outcomes in musculoskeletal by providing frequent, validated on .

Principles of Operation

Mechanical Principles

The mechanical principles underlying non-optical goniometers rely on the of to quantify angles. In such devices, the angle \theta subtended at the center of a is fundamentally determined by the of the s traversed along the to the r of the , yielding \theta = s / r in . This relationship stems from the definition of the as a dimensionless of measure. To convert to degrees, the formula becomes \theta^\circ = (s / (2\pi r)) \times 360^\circ, or equivalently \theta^\circ = (360 / C) \times s, where C = 2\pi r is the full ; this allows direct computation of angles from linear displacements along a calibrated or arc-shaped scale. Precision in mechanical goniometers is enhanced through the vernier scale principle, which enables interpolation for sub-degree readings. The main scale typically features graduations of 1° along a protractor-like dial, while the vernier scale—attached to a movable arm—consists of divisions slightly offset from the main scale, such as 10 divisions spanning 9° to achieve a least count of 0.1°. By aligning the vernier with the main scale, the user identifies the division where lines coincide most closely, adding the fractional value (e.g., n \times 0.1^\circ) to the main scale reading for the total angle. This method, analogous to linear vernier calipers but adapted for angular interpolation, is exemplified in devices like the vernier bevel protractor. Mechanical integrity is maintained via and locking mechanisms that facilitate controlled while countering and play. , often lubricated joints at the instrument's , allow the measuring arms to rotate freely with minimal resistance, but excessive can introduce errors during adjustment. Locking screws or clamps secure the arms post-alignment, applying pressure to eliminate backlash—the lost motion from clearances in the or —which could otherwise cause discrepancies on reversal. procedures involve zeroing the instrument against a known (e.g., a 90° ) and adjusting set screws to align scales, ensuring across measurements. Key error sources in mechanical goniometers include , arising from viewing the at an ; this is mitigated by aligning the eye to the plane. wear on pivots and arms over time increases backlash and , while adjustable arms allow fine-tuning to compensate. Proper , such as periodic and verification, is essential to preserve the instrument's precision.

Optical and Electronic Principles

Optical goniometers leverage principles of light and to achieve high-precision, non-contact measurements. In contact goniometry, accurate profiling of liquid droplets on solid surfaces is achieved through optical imaging techniques, such as capturing the droplet silhouette and applying the tangent method to determine the contact \theta. The measured contact \theta quantifies wettability and relates to interfacial tensions through Young's equation: \gamma_{sv} = \gamma_{sl} + \gamma_{lv} \cos \theta, where \gamma_{sv}, \gamma_{sl}, and \gamma_{lv} represent solid-vapor, solid-liquid, and liquid-vapor surface tensions, respectively; this equilibrium condition is fundamental for interpreting optical images of the three-phase contact line. Goniophotometers, a specialized optical variant, measure distribution through angular scanning geometries. A rotating mirror or detector setup directs emitted light at varying angles to capture angular while maintaining far-field conditions for accuracy. goniometers incorporate encoders to translate into quantifiable electrical signals. Incremental encoders, typically featuring a slotted disk and optical sensors, produce pulses proportional to ; is calculated as $360^\circ divided by pulses per , yielding fine increments such as \pm 1^\circ with a 360-pulse disk. decodes these quadrature pulses via microcontrollers to determine position and direction, with analog-to-digital conversion () applied in hybrid setups to digitize outputs for stable digital readouts. Calibration curves map encoder counts to true angles, minimizing nonlinearities and ensuring sub-degree accuracy. Error correction in electronic systems includes auto-zeroing, where software sets the current position as the zero reference—activated by aligning the device and invoking the zero function—to offset systematic drifts and enhance across measurements.

Applications

Surveying and Navigation

In the 18th and 19th centuries, goniometers such as served as essential instruments for measurement in triangulation surveys, enabling surveyors to determine positions across large areas by establishing networks of triangles from measured baselines. These devices, often consisting of graduated circles with sighting arms, facilitated the precise of survey points relative to known references, supporting geodetic efforts such as the Great Trigonometrical Survey of initiated in 1802. By the late 18th century, advancements like Jesse Ramsden's Great , enabled by his dividing engine, allowed angular precisions of 1 second of arc, crucial for extending baselines over hundreds of kilometers while minimizing cumulative errors in positional calculations. In military navigation, goniometers evolved into specialized protractors for calculation, particularly using mil-based scales to integrate directional bearings with topographic maps for coordinate determination. The U.S. Army's Graphic Training Aid () 05-02-012, a portable coordinate scale and protractor, exemplifies this application, featuring an outer scale (0-6400 ) for and and an inner scale (0-360 ) for general plotting. This tool enables soldiers to measure back , convert between and , and overlay coordinates on maps at scales like 1:25,000 or 1:50,000, supporting tasks such as patrol route planning and adjustment in field operations. Modern residual applications of portable goniometers persist in field , particularly within for measuring orientations of rock formations and core samples during on-site surveys. These compact devices, such as core orientation goniometers, allow geologists to quantify alpha and angles of drill cores or features with sufficient accuracy for subsurface structures, often achieving resolutions around 1 to support terrain analysis in remote environments. While largely supplanted by electronic total stations for high-precision work, such goniometers remain valued for their simplicity and portability in preliminary baseline extensions, where angular needs of approximately 0.1 degrees suffice for initial alignments before refined measurements.

Medicine and Rehabilitation

In medicine and rehabilitation, goniometers are primarily employed to measure the () in human joints, enabling clinicians to assess mobility impairments and guide therapeutic interventions. Physical therapists, physicians, and occupational therapists use these devices to quantify angular movements at joints such as the , , , and ankle, establishing baselines for conditions like , post-surgical recovery, or neurological disorders. For instance, normal flexion is typically 0-135 degrees, a range essential for activities like or climbing stairs, with deviations indicating potential functional limitations. The standard procedure involves the universal goniometer, a handheld with two adjustable arms and a protractor-like dial, aligned with anatomical landmarks for precise . To measure active or passive , the stabilizes the proximal segment of the , moves the distal segment to its end range, palpates bony landmarks (e.g., for or lateral for ), and positions the goniometer's stationary arm parallel to the proximal segment and the moving arm along the distal segment. Measurements are recorded in degrees, often averaged over three trials to account for variability, ensuring consistency in clinical documentation and treatment planning. In rehabilitative therapy, goniometers facilitate tracking patient progress following injuries or surgeries, such as , by comparing serial measurements against normative values to adjust exercise protocols. This objective data supports goal-setting, such as restoring full extension post-fracture, and informs discharge criteria when reaches functional thresholds. Increasingly, goniometer applications integrated with smartphones enable home-based monitoring, allowing patients to self-assess via camera-based alignment and share data with therapists through platforms, enhancing adherence and remote care. Despite their utility, manual goniometers exhibit accuracy challenges, including inter-rater variability of up to 5 degrees due to differences in and arm alignment, which can affect treatment decisions in precision-dependent scenarios. Digital models mitigate this by providing electronic readouts and higher ( coefficients often exceeding 0.95), reducing errors through automated calibration and visual guides. In the , advanced systems, including markerless video-based technologies and wearable sensors, are increasingly supplanting traditional goniometers in clinical settings for more comprehensive, real-time joint analysis during dynamic activities. These systems offer superior accuracy for multi-joint assessments in , capturing three-dimensional without manual intervention, though they require specialized equipment and are often reserved for research or advanced clinics.

Crystallography and Materials Science

In , the goniometer has been instrumental since the early for measuring s between faces, enabling the identification of crystal symmetry and structure. The contact goniometer, invented by Arnould Carangeot in 1783, was instrumental in crystallography and used by René-Just Haüy for measuring angles between crystal faces, enabling his foundational work in published in Traité de Minéralogie (1801). This allowed the observation that corresponding angles in crystals of the same substance remain constant regardless of size or habit, a key principle in morphological crystallography. Subsequently, introduced the reflecting goniometer in 1809, which used light reflection off crystal faces to achieve higher accuracy on smaller specimens, surpassing the limitations of contact-based methods and revolutionizing angle measurements. In modern applications, goniometers serve as critical components in single-crystal X-ray diffractometers, where they provide precise of to align planes with the beam for analysis. These systems typically employ 3- or 4-circle goniometers, allowing rotation about multiple axes (such as χ, φ, ω, and 2θ) to collect comprehensive data from various , essential for determining atomic arrangements in materials. By measuring interfacial angles, crystallographers infer ; for instance, in cubic systems, right angles of 90° between adjacent faces indicate high , distinguishing them from lower-symmetry classes like monoclinic or triclinic. This angular data, combined with patterns, enables the assignment of space groups and parameters. Extending to materials science, goniometers facilitate thin-film analysis in techniques like X-ray diffraction (XRD), where they measure lattice orientations and mismatches between epitaxial films and substrates to assess strain and epitaxy quality. In semiconductor fabrication, for example, precise angular control reveals how closely the film's lattice matches the substrate's, influencing properties like electrical conductivity and defect density. Such measurements are vital for optimizing heterostructures in devices like LEDs and solar cells. Goniometers in these setups achieve arcsecond-level precision—often within a few arcseconds of repeatability—ensuring accurate positioning for high-resolution diffraction patterns that resolve subtle structural features.

Optics and Communications

In optics, goniophotometers are specialized instruments used to measure the of sources, such as LEDs and lamps, as a of emission angle. These devices rotate the light source or detector around multiple axes to capture the of , enabling the characterization of shapes and efficiencies. Far-field goniophotometers, often classified as Type C according to standards from the (CIE), position the detector at a sufficient from the source to approximate conditions, where intensity remains constant regardless of range due to the . This angular measurement yields the luminous intensity distribution, denoted as I(\theta), where I represents intensity in candelas and \theta is the polar angle from the source's . Such data is plotted in 3D polar coordinates to visualize , defined as the full angle at half-maximum (FWHM) of the intensity profile, which quantifies how rapidly the spreads. For example, in LED testing, these plots reveal asymmetries or lobes in the , critical for applications like or displays. In communications, goniometers facilitate radio by determining the bearing of electromagnetic signals through angular scanning. The Bellini-Tosi goniometer, developed in the early 1900s by Italian engineers Ettore and Alessandro Tosi, employs two orthogonal loop antennas connected to fixed field s and a rotatable search to measure phase differences, producing a null or maximum signal at the signal's . This early 20th-century innovation enabled precise localization of radio transmitters, foundational for and military applications, and was widely adopted until the mid-20th century. Modern adaptations extend to antenna pattern evaluation, where goniometers rotate test s to generate 3D polar plots of gain versus angle, assessing and in wireless systems. Contemporary uses include optic stages, where motorized goniometers provide sub-microradian rotational precision for between fibers or to photonic devices. These stages, often integrated with linear positioners, minimize insertion losses by optimizing in and sensing applications, such as systems.

Manufacturing and Surface Analysis

In manufacturing, goniometers play a crucial role in by enabling precise measurement of to assess material wettability, which is essential for in processes like , , and . A goniometer projects a droplet onto a and captures its shape via high-resolution , allowing calculation of the angle formed at the liquid-solid-vapor . Surfaces with a contact angle θ greater than 90° are considered hydrophobic, influencing applications such as anti-fouling s in industrial equipment, while θ less than 90° indicates hydrophilic behavior suitable for enhanced bonding in composites. This method is widely adopted in sectors like and automotive to verify surface treatments, such as , ensuring optimal for subsequent assembly steps. For blade inspection, goniometers provide non-contact of angles, critical for maintaining performance and safety in tools used across industries. In knife and tool manufacturing, devices like laser goniometers measure bevel angles, typically around 20° for standard utility knives, to ensure uniformity and sharpness retention. In and production, specialized goniometers inspect blades—thin metal strips that remove excess or from rollers—by quantifying wear angles and edge deviations, often targeting tolerances of 1.5° to 1.7° to prevent defects like streaking or uneven application. These inspections help minimize and material waste, with handheld or automated units facilitating rapid in-line checks during production runs. Goniometers also facilitate surface tension analysis through the pendant drop method, where a droplet is suspended from a needle, and its profile is imaged to determine interfacial properties vital for formulating inks, adhesives, and coatings in . The drop's shape, influenced by gravity and , is analyzed using optical tensiometry integrated into goniometer systems, yielding values that guide optimization, such as ensuring stable fluid flow in or spray applications. This technique is particularly valuable in chemical and industries, where precise tension measurements (e.g., in the range of 20–50 mN/m for common industrial s) prevent issues like bubbling or poor during production. In assembly processes, automated goniometer stages enable precise angular positioning of components, supporting high-throughput in sectors like semiconductors and . These motorized platforms, often with resolutions down to arcseconds, rotate or tilt workpieces for alignment during bonding or inspection, integrating with robotic systems to achieve in multi-axis setups. For instance, in electronics assembly, goniometer stages position wafers or lenses to sub-degree accuracy, reducing misalignment errors that could compromise yield. Post-2020 advancements have seen goniometer stages integrated with technologies for enhanced defect detection in , allowing comprehensive surface profiling and angular analysis of complex parts. This combination, often employed in automated lines, uses goniometers to orient scanned objects precisely, enabling detection of microscopic flaws like cracks or voids in castings and machined components through high-fidelity data. Such systems, leveraging Industry 4.0 principles, have improved efficiency in by providing real-time, non-destructive evaluations with minimal human intervention.

References

  1. [1]
    Goniometer - StatPearls - NCBI Bookshelf - NIH
    Jun 7, 2020 · A goniometer is a device that measures an angle or permits the rotation of an object to a definite position.Missing: history | Show results with:history
  2. [2]
    The Evolution of the Goniometer - Nature
    The first instrument used for the purpose of measuring the interfacial angles is that known as the contact-goniometer, and was devised by Carangeot in 1783; it ...
  3. [3]
    Wollaston Goniometer - UQ Physics Museum
    This object is a goniometer, made by Troughton & Simms around 1880. Its design is based on the goniometer developed by English chemist and mineralogist ...
  4. [4]
    History of the development of the crystallographic goniometer - Gale
    Goniometers developed from the simple contact models to the more complex three-circle instruments. Goniometer use declined with the introduction of X-ray ...
  5. [5]
    Goniometer - an overview | ScienceDirect Topics
    A goniometer is a portable device used to measure joint angles and range of motion (ROM) in a non-invasive manner.
  6. [6]
    Analysis of the concurrent validity and reliability of five common ...
    Nov 27, 2023 · Goniometry employs various measurement tools for the clinical assessment of range of motion (ROM), a fundamental parameter used to evaluate the ...<|control11|><|separator|>
  7. [7]
    [PDF] The Virtual Goniometer: Demonstrating a new method for measuring ...
    Apr 16, 2021 · The contact goniometer was originally designed in the 1780s to measure the angles on crystals (Burchard, 1998) and first appeared in archaeology ...
  8. [8]
    [PDF] Precision Measurement of Inter-Facet Angles on Faceted Gems ...
    In this study, we examine the feasibility of using a well-established optical instrument—a classical two-circle reflecting goniometer—to measure the angles on ...Missing: definition | Show results with:definition
  9. [9]
    New High-Precision Instrument Enables Rapid Measurements of ...
    May 29, 2018 · The goniometer can position protein crystals with a precision of 25 nanometers (4,000 times smaller than the width of a human hair) and ensures ...Missing: definition applications
  10. [10]
    goniometer - American Heritage Dictionary Entry
    An instrument used to measure angles or to set objects to a desired angle. Examples include optical instruments used in surveying or for measuring crystal ...
  11. [11]
    Goniometer - Etymology, Origin & Meaning
    word-forming element meaning "device or instrument for measuring;" commonly -ometer, occasionally -imeter; from French -mètre, from Greek metron "a measure," ...Missing: function components units
  12. [12]
    GemRed Goniometer: A Tool for Measuring Angles
    Sep 11, 2023 · The graduated scale comprises evenly spaced markings or divisions encircling its circumference. These marks are calibrated in degrees, radians, ...
  13. [13]
    Goniometry: Introduction - Brookbush Institute
    Goniometry measures the amount of osteokinematic motion available at a joint in total number of degrees. Unit of Measurement: As most bones pivot in an arc ...Missing: components | Show results with:components
  14. [14]
    Inclinometer - Physiopedia
    It is commonly used in physiotherapy to measure the range of motion (ROM) of joints and very similar to a goniometer. The ROM is the amount of movement that a ...
  15. [15]
    Ancient History in depth: Astronomical Instruments Through Time
    Feb 17, 2011 · The astrolabe was known, at least in theory, to the ancient Greeks, but it was within the Islamic world that it developed into a precision ...
  16. [16]
    [PDF] The Virtual Goniometer: A new method for measuring angles on 3D ...
    Nov 25, 2020 · The goniometer has a long history. It was first described by Gemma Frisius (a doctor, mathematician, and cartographer) in 1538 and was ...
  17. [17]
    Gemma Frisius (1508 - 1555) - Biography - MacTutor
    Gemma Frisius made many astronomical observations. In particular he recorded comets in July 1533, January 1538 and 30 April 1539. Some of these comet ...
  18. [18]
    (IUCr) René-Just Haüy and the birth of crystallography
    Dec 4, 2022 · Criticism of Haüy's measurements. All his life, Haüy used the goniometer of Carangeot, the best accuracy of which being one-tenth of a degree.
  19. [19]
    XVI. Description of a reflective goniometer - Journals
    Description of a reflective goniometer. William Hyde Wollaston. Google Scholar ... Published:01 January 1809https://doi.org/10.1098/rstl.1809.0018 ...
  20. [20]
    RA 6in MILS Mk 1 Protractor - Australian War Memorial
    Apart from being a Royal Artillery protractor, the history of this particular instrument is unknown. Protractors were used by artillery units to make accurate ...
  21. [21]
    US3197753A - Digital goniometer - Google Patents
    DIGITAL GONIOMETER Filed Sept. 28. 1960 3 Sheets-Sheet 2 C'OMPU TEE INVENTOR. ALEXANDER M. VOUTSAS July 27, 1965 A. M. VOUTSAS 3,197,753. DIGITAL GONIOMETER ...
  22. [22]
    The Machinist - GovInfo
    Protractors.—The bevel protractor (fig. 6) is a protractor provided with attached straightedges and is used in the machine shop to measure or scribe lines ...
  23. [23]
    [PDF] Investigation of Springback Associated With Composite Material ...
    This procedure can be seen in figure 7, using a universal bevel protractor with an accuracy to one-twelfth of a degree (5 minutes). These locations on the ...
  24. [24]
    Bevel Square | ClipArt ETC
    Feb 2, 2010 · A sliding T bevel is an adjustable gauge for setting and transferring angles. The handle is usually made of wood or plastic and is connected to a metal blade.
  25. [25]
    Engineering & Drafting | National Museum of American History
    Makers produced protractors that read minute fractions of angles, particularly when a vernier was added to the instrument. Mechanics or ...Missing: goniometer | Show results with:goniometer
  26. [26]
    The reliability and measurement error of protractor-based ...
    The use of hand held, manual finger goniometers has been shown to have high inter-and intrarater reliability (Gibson, 2015; van Kooij et al., 2017) . ... Inter- ...
  27. [27]
    War | National Museum of American History
    Felsenthal Artillery Protractor ... The form of the signature indicates the protractor was probably manufactured for the U.S. Army in the 1960s.Missing: goniometer royal
  28. [28]
    Description of a reflective goniometer
    By William Hyde Wollaston,. M.D.Sec. R.S. Read June 8,1809. [Phil. Trans. 1809, 253 ]. The instrument here described by the author is designed to obviate.
  29. [29]
    Wollaston's reflective goniometer | Opinion - Chemistry World
    Sep 2, 2014 · Wollaston had the ingenious idea of using crystal faces as mirrors to measure the angles between them.
  30. [30]
    [PDF] The Science of Goniophotometry - Pro-Lite Technology
    Introduction. This technical note reviews the science of goniophotometry – the measurement of luminous intensity as a function of angle from a light source.
  31. [31]
    Goniophotometers for Displays - Products - Instrument Systems
    The DMS series of goniometer systems are used to measure and qualify electro-optical displays in typical application scenarios, e.g. viewing angle, homogeneity ...
  32. [32]
    Contact Angle | Measurements - Biolin Scientific
    Contact angle measurements are typically done by using either optical or force tensiometers. Contact angles can be divided into static, dynamic, and roughness ...2optical Tensiometer For... · 3force Tensiometer For... · Wilhelmy Plate Method
  33. [33]
    [PDF] LEOI-98 Intermediate Spectrometer Goniometer
    It features a rotatable telescope and collimator, a graduated circular scale ... distance between collimator & telescope 120 mm. Slit width. 0.02 - 2 mm ...
  34. [34]
    Spectrometer Goniometer - Advanced Researcher Version - Holmarc
    A new high precision 0.0001 degree resolution spectrometer goniometer. It features low dark current linear Si-Photodiode detection unit for low light ...Missing: LED | Show results with:LED
  35. [35]
    LEDGON Goniometer System Lightproof LED test system
    Motorized 2-axis goniometer in a lightproof housing; High angle precision and reproducibility with an angle resolution of up to 0.1° for the entire anterior ...
  36. [36]
    Autocollimation | Precision Optical Inc.
    Transmission deflection angles (i.e. beam deviation) can be verified to 1 arc second accuracy. Combined with our autocollimators, our goniometers give Precision ...
  37. [37]
    PrismMaster® - Goniometer for optical angle measurements
    PrismMaster® goniometers from TRIOPTICS are used for high-precision optical angle measurements on prisms, polygons and wedges.Missing: beam deviation
  38. [38]
    High-Precision Motorized Rotary Stages and Goniometers - PI-USA.us
    PI offers a wide range of direct-drive rotary stages, worm-gear driven rotary stages, and precision goniometers designed for demanding automation and research ...
  39. [39]
    GNM1 ±30° Motorized Goniometer with Stepper Motor ... - Thorlabs
    In stock 4-day deliverySep 12, 2024 · GNM1 - ±30° Motorized Goniometer with Stepper Motor, Integrated Controller, 30 mm to Axis of Rotation, Imperial.
  40. [40]
    OES introduces AK170-24 goniometer series for precision motion
    Oct 24, 2025 · The AK170-24 Series of goniometer stages feature four motor options. The -01 option (pictured) is Stepper Motor driven. The -02 option is driven ...
  41. [41]
    ANT20G Single-Axis Direct-Drive Goniometer - Aerotech
    Our ANT20G goniometers are designed for high-speed, ultra-precise positioning applications such as the angular alignment of components.
  42. [42]
    What are goniometer stages and where are they used?
    A goniometer stage produces partial rotation around a fixed point or axis above the stage. Rotation angles can range from as little as a few arc-seconds to as ...
  43. [43]
    Comparison of a Smartphone App to Manual Knee Range of Motion ...
    Apr 4, 2022 · The purpose of this study was to determine the accuracy of digital technology in assessing knee range of motion using a smartphone app.
  44. [44]
    [PDF] Validation of a Novel Smartphone Accelerometer-Based Knee ...
    The iPhone goniometer is found to be a reliable tool for the measurement of subtle knee flexion in the clinic setting and correlates closely with the ...<|separator|>
  45. [45]
    A Digital Goniometer based on encoders for measuring knee-joint ...
    This work introduces a novel method of knee joint measurement. The design is mainly based on the contactless magnetic absolute encoder AS5040 (Austria ...
  46. [46]
  47. [47]
    [PDF] 6, m=10−3, c=10−2, k=103, M=106, G=109, T=1012, P=1015 Physic
    OpenStax Chapter 26 Equations - Optical Instruments & Vision. Angles in radians θ = s/r angle = arc length / radius = separation / distance away. Lens power.
  48. [48]
    [PDF] Chapter 3: ANGULAR MEASUREMENTS - Cloudfront.net
    Vernier Bevel Protractor (Universal Bevel Protractor):. It is a simplest instrument for measuring the angle between two faces of a component. It consists of ...
  49. [49]
    What is Vernier Bevel Protractor? Working, Diagram & Uses
    May 1, 2022 · Vernier Bevel Protractor is an instrument used to measure angles to an accuracy of 5 minutes (5') or 1/12 of one degree. The vernier principle ...
  50. [50]
    Goniometry - Physiopedia
    A goniometer is the most common instrument used to measure range of motion. If a patient has altered range of motion in a particular joint, the therapist can ...
  51. [51]
    [PDF] Use Of Optical Techniques In Studies Of Wear Rates Of Anodized ...
    Using Snell's law (nQsin 5^ = D^sin ... by means of an NRL Contact Angle Goniometer Model A-100. ... Contact angle measurements were made 2 minutes after a.<|separator|>
  52. [52]
    Contact Angle Measurements and Wettability
    The well-known Young Equation describes the balance at the three-phase contact of solid, liquid, and gas. γSV = γSl + γlv cosθY. Equation ...
  53. [53]
    How to Calculate Encoder Resolution | Dynapar
    Encoder resolution is the number of pulses per revolution (PPR) or bits output by the encoder during one 360 degree revolution of the encoder shaft or bore.Missing: goniometer principles
  54. [54]
    [PDF] Development of a Dynamic Goniometer with an Incremental Encoder
    Digital goniometers have been constructed using different electronic principles, especially using resistance variations in potentiometers. In this paper we ...
  55. [55]
    [PDF] Digital goniometer G-1D
    In order to switch on the mode choose the option «Zero indicator» in the point of main menu «View» of the «Goniometer» program (or press icon or «F8» key). When ...
  56. [56]
    [PDF] History of Angle Measurement - International Federation of Surveyors
    Apr 21, 2005 · The paper covers the period from the time when angles were measured using rather primitive methods and charts the requirement for increasing ...
  57. [57]
    [PDF] GTA 05-02-012
    Missing: goniometer 1981
  58. [58]
    Kenometers and Goniometers Archives - Geology Superstore
    Introducing our premium line of Kenometers and Goniometers, essential tools for precise measurement and analysis of geological structures and orientations.
  59. [59]
    Discoverer® Goniometer Core Orientation Tool (Ezy-Logger)
    A lightweight, compact and accurate core orientation tool to measure Alpha and Beta angles and lineations within wireline core structures.
  60. [60]
    Knee joint kinematics in gait and other functional activities ... - PubMed
    The results indicate gait and slopes require less than 90 degrees of knee flexion, stairs and chairs 90-120 degrees of flexion and a bath approximately 135 ...
  61. [61]
    Goniometric measurement reliability in physical medicine - PubMed
    Though goniometric measurements are commonplace in the field of physical medicine, their reliability has not been adequately established.
  62. [62]
    Validity and Reliability of 2 Goniometric Mobile Apps - PubMed
    Results: Interrater reliability for each of the smartphone apps, inclinometer and UG were excellent (ICC = .995-1.000). Concurrent validity was also good (ICC = ...
  63. [63]
    The Future of Clinical Active Shoulder Range of Motion Assessment ...
    Jan 23, 2025 · This narrative review examines video-based pose technologies and markerless motion capture, focusing on their clinical application for shoulder ROM assessment.
  64. [64]
    Methods and Instruments of Mineralogy - goniometer, petrological ...
    Reflecting goniometer. The contact goniometer was followed in 1809 by the single-circle reflecting goniometer of Wollaston. With its introduction precision ...
  65. [65]
    Single-crystal X-ray Diffraction - SERC (Carleton)
    May 17, 2007 · Single-crystal diffractometers use either 3- or 4-circle goniometers. These circles refer to the four angles (2θ, χ, φ, and Ω) that define ...
  66. [66]
    [PDF] Back-to-Basics tutorial: X-ray diffraction of thin films
    Oct 13, 2021 · The Bragg Equation relates the angular position of diffracted X-rays to the lattice spacing and underpins all XRD measurements. the goniometer, ...
  67. [67]
    Extreme precision in X-ray diffraction - Malvern Panalytical
    Apr 10, 2019 · There are also rotations in the goniometer that are controlled to within a few arc seconds. An arcsecond is the angle that the hour hand on ...
  68. [68]
    Stereographic Projection of Crystal Faces - Tulane University
    Sep 22, 2014 · First we define the interfacial angle between two crystal faces as the angle between lines that are perpendicular to the faces. Such a lines are ...
  69. [69]
    [PDF] global interlaboratory comparison of goniophotometer ...
    Sep 30, 2017 · To measure total luminous flux and partial luminous flux, goniophotometer must be scanned with C angle intervals much smaller than 90°. The ...
  70. [70]
  71. [71]
    LGS Goniometer System - Instrument Systems
    The LGS goniometer system is a far-field goniophotometer for measuring spatial radiation properties of SSL light sources, including angle-dependent properties.
  72. [72]
    Measuring Divergence of Custom Optical Fibers - Ophir Optronics
    In general, Goniometric Radiometers yield the most accurate measures, providing direct angular profiles with effective angular scan at constant radius with ...
  73. [73]
    [PDF] Stowell, E. Z.
    done by Bellini and Tosi.3. They employed two triangular loops at right angles, open at the top, and excited from a goniometer. A single vertical wire was ...
  74. [74]
    [PDF] Characterizing Radio Channels - DSpace@MIT
    Sep 1, 2004 · ... Bellini and A. Tosi in 1908.'53 A Bellini-Tosi system has two ... goniometer" constituted by two field coils and a rotating search coil ...
  75. [75]
    [PDF] Radio Direction Finding - UDXF
    Bellini and Tosiinvented the Bellini-Tosi Gonimeter, but it took many years until production. A coil is rotated inside an electrical field fed from the N-S and ...
  76. [76]
    Active Photonics Alignment | Fiber Optic Alignment Stages - PI-USA.us
    They are based on a combination of linear stages, and tip/tilt stages or goniometers for rotation. In the case of the F-308, F-408 and F-508 XYZ systems, ...Missing: modern | Show results with:modern
  77. [77]
    Goniometric Stages - Thorlabs
    A goniometer or goniometric stage is a device used to rotate an object precisely, within a small angular range, about a fixed point in space.
  78. [78]
    Contact Angle Goniometer 101: A Guide to Successfully Measuring ...
    A contact angle goniometer measures the angle between a liquid droplet and a solid surface, providing information about wettability and surface tension.
  79. [79]
    KeyLink Contact Angle Goniometer for Precise Surface Testing
    Contact angle meters are often used to evaluate the effectiveness of plasma treatment by measuring the wettability of a surface after treatment. Plasma ...
  80. [80]
    The Hobbi-Goniometer - CATRA
    Our very lightweight, low cost, easily used, handheld laser goniometer measures inclusive blade edge angles of various knives.
  81. [81]
    Order Workflow of Customer Ordering | DEKEJIE
    Use a contact angle goniometer to inspect whether the angle error of blade edge is between 1.5° and 1.7° in order to ensure consistent pressure between the ...
  82. [82]
    Use Of Goniometer in Tissue Manufacturing - Nip Impressions
    Apr 30, 2018 · Use a GONIOMETER to measure doctor blade wear angles. The GONIOMETER is a neglected but very important tool for diagnosing doctor blade issues in tissue mills.Missing: inspection | Show results with:inspection
  83. [83]
    Pendant drop method for surface tension measurements
    Sep 1, 2020 · Pendant drop is an optical method. Surface and interfacial tension measurements can be performed optically using pendant drop shape analysis.
  84. [84]
    Pendant drop | KRÜSS Scientific
    In the pendant drop method, the surface tension or interfacial tension is calculated from the shadow image of a pendant drop using drop shape analysis.Missing: manufacturing | Show results with:manufacturing
  85. [85]
    Motorized Goniometer Stages - Optimal Engineering Systems
    Motorized goniometers assist in fine angular adjustments during the precise assembly or inspection of aerospace components and robotic calibration.
  86. [86]
    Exploring the potential of 3D scanning in Industry 4.0: An overview
    This paper discusses 3D Scanning, its working process, and its adoption for reverse engineering and Industry 4.0 culture.Missing: goniometer | Show results with:goniometer